UltraPly™ TPO Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and “P” Assemblies Factory Mutual Approvals (FM) 1|P age February 2014 Table of Contents Underwriters Laboratories (UL) External Fire Ratings ............................................................ 5 UL assembly numbers change frequently due to the addition of newly approved assemblies. For this reason the listed assemblies do not have associated assembly numbers, but all are approved assemblies with UL. Please use the link below or contact your Building Services Advisors for the associated assembly numbers. You will look for the listed “Type” then the listed “Class” and search for the associated assembly. ................................................................................ 7 Firestone V-Force Vapor Barrier System ............................................................................................................. 7 Firestone Fully Adhered Systems ........................................................................................................................... 7 Firestone Fully Adhered Systems ........................................................................................................................... 8 Firestone Fully Adhered Systems with UltraPly TPO SA membrane ......................................................... 8 Firestone Fully Adhered Systems with UltraPly TPO XR ................................................................................ 9 Firestone Fully Adhered Systems with UltraPly TPO XR ................................................................................ 9 Firestone Mechanically Attached Systems ........................................................................................................ 10 Firestone Mechanically Attached Systems ........................................................................................................ 10 Firestone Mechanically Attached Recover Systems ...................................................................................... 10 Firestone Mechanically Attached Systems with UltraPly TPO XR ............................................................. 11 UL Internal Fire Ratings .................................................................................................. 11 UL Roof Deck Constructions and “P” Assemblies ........................................................................................... 12 Factory Mutual General Information.................................................................................. 12 Ground Roughness Definitions .............................................................................................................................. 12 Ballasted Systems ...................................................................................................................................................... 13 General Notations ...................................................................................................................................................... 13 Field/Corner/Perimeter Definitions ...................................................................................................................... 13 Perimeter and Corner Treatment of Adjoining Buildings ............................................................................ 14 Prescriptive Enhancement Options: Perimeter and Corner ....................................................................... 15 Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System ................................. 15 Firestone Fully Adhered Uplift Ratings – Standard UltraPly TPO ............................................ 16 New Construction, Concrete Deck, Adhesively Attached Insulation, Without Coverboard............ 16 New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard .................. 16 New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard .................. 16 New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With Coverboard ................................................................................................................................................................... 18 New Construction, Steel, Vapor Barrier, Adhesively Attached Insulation ............................................ 18 New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard .... 18 New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard .... 19 New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 19 2|P age February 2014 New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 20 New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 20 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane ..................................... 21 New Construction, Steel Deck, Mechanically Attached Insulation, Without Coverboard ............... 21 New Construction, Concrete Deck, Mechanically Attached Insulation, Without Coverboard........ 21 New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation....................................................................................................................................................................... 22 New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached ....... 22 Insulation....................................................................................................................................................................... 22 New Construction, Steel Deck, Insulation with Mechanically Attached Coverboard ........................ 23 New Construction, Concrete Deck, Insulation with Mechanically Attached Coverboard ................ 23 Re-Roof/New Construction, Concrete and Gypsum, Adhesive Attachment Insulation/Coverboard.............................................................................................................................................. 24 Recover, Concrete Deck, Mechanically Attached Insulation, Without Coverboard ........................... 25 Recover, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation ..... 25 Recover, Concrete Deck, Mechanically Attached Insulation/Coverboard ............................................. 26 Recover, Steel Deck, Mechanically Attached Insulation/Coverboard..................................................... 26 Recover, Various Deck Types, Adhesive Attachment Insulation/Coverboard .................................... 26 Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane .................... 27 New Construction, Steel or Concrete Deck, Insulation without Coverboard, UltraPly XR membrane ..................................................................................................................................................................... 27 New Construction, Steel or Concrete Deck, Insulation with Coverboard, UltraPly XR membrane .......................................................................................................................................................................................... 27 New Construction, Concrete Deck, Adhered Coverboard Only, UltraPly XR membrane ................ 29 New Construction, Concrete Deck, UltraPly XR membrane ....................................................................... 29 New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR membrane ..................................................................................................................................................................... 30 New Construction, Lightweight Insulated Concrete, UltraPly XR membrane ..................................... 30 Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, Without Coverboard...... 30 Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Coverboard ............ 30 Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane .......... 31 New Construction, Steel, Mechanically Attached Insulation, Single Weld ........................................... 31 New Construction, Steel, Insulation with Coverboard, Single Weld....................................................... 31 New Construction, Concrete, Insulation with Coverboard, Single Weld ............................................... 32 Recover, Metal Building, Insulation with Coverboard .................................................................................. 33 Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld .............................................................. 34 3|P age February 2014 Recover, Concrete Deck, UltraPly TPO XR membrane, Single Weld ...................................................... 34 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 34 Invisiweld System, Induction Welded ................................................................................................................ 34 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 35 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 36 Recover, Metal Building, Invisiweld System, Induction Welded .............................................................. 36 Factory Mutual Ballast Guidelines ..................................................................................... 36 Ground Roughness B ................................................................................................................................................ 36 Ground Roughness C ................................................................................................................................................ 37 Ground Roughness D ................................................................................................................................................ 38 4|P age February 2014 Underwriters Laboratories (UL) External Fire Ratings All regional building codes and most local building code officials require that roofing systems meet minimum performance requirements when exposed to external fire sources. The accepted method for measuring external fire resistance is ASTM E-108. This test standard, and closely related standards such as Underwriters Laboratories UL-790 and Uniform Building Code 15-2, is used to determine the ability of a roof system to hinder the horizontal spread or vertical penetration of an external fire source. In accordance with these standards, all classified roof covering assemblies fall into one of the three following categories.1 • CLASS A: Includes roof coverings which are effective against severe fire exposures • CLASS B: Includes roof coverings which are effective against moderate fire exposures • CLASS C: Includes roof coverings which are effective against light fire exposures For insulated assemblies over non-combustible roof decks, any classified roofing assembly may be installed over a new roof deck, an existing roof deck or over an existing roofing assembly. Underwriters Laboratories states that “any classified roofing system may be applied over a pre-existing roof system (Class A, B, C, verifiable or not) of the same deck type and establishes for that roof the classification of the new system”. Also, an assembly classified over a combustible deck may be installed over an existing noncombustible deck and establish for the assembly the rating of the new system. A non-combustible deck rated assembly must be tested and classified over a combustible deck in order to obtain the desired classification of the new assembly. Total insulation thickness of combined existing and new roofing systems may not exceed the total maximum allowable for the new roofing system, and non-insulated systems are not intended for use over insulated systems. Noncombustible Roof Decks (NC): Steel, Concrete, Poured Gypsum – require testing for horizontal spread of flame. Combustible Roof Decks (C): Wood, Plywood, Tectum – require testing for both horizontal spread and vertical penetration of flame. The class of roof covering required by each regional building code depends upon many factors, including the use and location of the building and the type of construction. The local building authority should always be consulted as to what the roofing assembly classification will need to be for each roofing project. It should be noted that these classifications apply to roofing assemblies, and NOT the roofing membrane. A roofing membrane that is classified as part of a Class A assembly when installed over a particular insulation may not qualify as part of a Class A assembly with another insulation. The “UL Item Number” in the following listings has been added as a service to those who have the UL Building Materials Directory. It identifies the UL listing from which our Code Approval Guide listing derives (e.g., “A,FA,23” means Class A, Fully Adhered, item number 23; “B,MA,04” means Class B, Mechanically Attached, item number 04, etc.). General Notations • • • • • PLEASE NOTE: Not all UL-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. If a discrepancy occurs between this guide and UL Certifications, the published information located in the UL Certifications Directory at www.ul.com should be adhered and utilized. Noncombustible decks Classifications are acceptable for use over combustible (15/32” minimum plywood) decks when 1/2” gypsum board or ¼” DensDeck® are used directly over the deck with all joints staggered 6” minimum from plywood joints. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. HailGard Insulation is an acceptable alterative to all insulations in the following Classifications except where DensDeck is stated. **Water Based Bonding Adhesive –P (WBBA-P) is an equivalent to Water Based Bonding Adhesive-S (WBBA-S).** Assemblies in red font are recent additions to the Code Approval Guide. 1 Underwriters Laboratories Roofing Materials and Systems Directory, January, 2008, page 1. 5|P age February 2014 Verify the included assemblies in the charts below with the associated Firms (UL, FM, etc). Not all of the information included in the RoofNav assemblies will be listed in the charts below. Verify that all assemblies meet Firestone Building Products warranty requirements with the associated regions technical team. UL website: FM Website: UL Online Certifications Directory www.RoofNav.com 6|P age February 2014 UL assembly numbers change frequently due to the addition of newly approved assemblies. For this reason the listed assemblies do not have associated assembly numbers, but all are approved assemblies with UL. Please use the link below or contact your Building Services Advisors for the associated assembly numbers. You will look for the listed “Type” then the listed “Class” and search for the associated assembly. http://database.ul.com/cgibin/XYV/template/LISEXT/1FRAME/showpage.html?name=TGFU.R9516&ccnshorttitle=Roofing+Systems&o bjid=1074351895&cfgid=1073741824&version=versionless&parent_id=1073993597&sequence=1 Firestone V-Force Vapor Barrier System Adhesive: UltraPly Bonding Adhesive, Single Ply LVOC Bonding Adhesive or Water Based Bonding Adhesive S Construction: New or Tear-off Classification: See Note 1 Below Deck Vapor Barrier Roofing System Maximum Slope Class, Type NC “V-Force”, Any Insulated UL Classified modified bitumen system, (See Note 1) A/B/C, Mechanically (See self adhered BUR system, EPDM, or TPO membrane system. Attached or Fully Note 1) Insulation may be adhered with Firestone "I.S.O. Twin Adhered Pack", “I.S.O Stick" or "I.S.O. Spray S". Note 1: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system, currently limited to a noncombustible deck. Firestone Fully Adhered Systems Membrane: Adhesive: Construction: Classification: Deck Type UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum (80 mil) UltraPly Bonding Adhesive, Single Ply LVOC Bonding Adhesive or Water Based Bonding Adhesive S New, Retrofit or Tear-off Class A Insulation Maximum Insulation Assembly Minimum Membranes Class, Type Slope Thickness Insulation (Optional): Firestone ISO 95+ GL or Resista Barrier Board: DensDeck Any ¼” 2-½” UltraPly TPO A, Fully Adhered Any Classified LWIC or structural Concrete Any 2-½” UltraPly TPO A, Fully Adhered C/NC Insulation (Optional): Firestone ISO 95+ GL Barrier Board: DensDeck Any ¼” 2” UltraPly TPO A, Fully Adhered Insulation (Optional): Firestone ISO 95+ GL or Resista or FiberTop B, C, E, or S Barrier Board: DensDeck Any C/NC 1-½” ReflexEON A, Fully Adhered Any 7/16” 1-¼” UltraPly TPO A, Fully Adhered --Any ½” UltraPly TPO A, Fully Adhered --Any ½” UltraPly TPO A, Fully Adhered Any ½” ½” Platinum membrane w/WBBA only A, Fully Adhered C/NC NC NC C/NC C/NC C/NC Insulation: Firestone ISO 95+ GL or Resista Coverboard: Oriented Strand Board (OSB) Slip Sheet: 2 layers VersaShield Underlayment or VersaShield FB-2S Insulation: Firestone ISO 95+ GL Slip Sheet: 2 layers VersaShield FB-1S Insulation: Firestone ISO 95+ GL, mechanically attached Insulation: Firestone ISO 95+ GL Coverboard: Firestone Resista or Firestone ISOGard HD ¼” 7|P age February 2014 Firestone Fully Adhered Systems Deck Type NC NC Insulation Assembly Insulation (Optional): Firestone ISO 95+ GL or Resista Coverboard: Firestone FiberTop B, C, E or S Insulation (Optional): Firestone ISO 95+ GL or Resista or FiberTop B, C, E, or S, mechanically fastened Barrier Board: FiberTop C, E or S Insulation Minimum Thickness Maximum Slope Membranes Class, Type Any ½” ½” UltraPly TPO A, Fully Adhered Any ½” ½” ReflexEON A, Fully Adhered NC Insulation (Optional): Firestone ISO 95+ GL or FiberTop B, C, E or S Any ¼” ReflexEON A, Fully Adhered C/NC Insulation (Optional): Firestone ISO 95+ GL Cover Board: Firestone ISOGARD HD or Resista Any 1” ¼” UltraPly TPO, ReflexEON A, Fully Adhered NC Insulation (Optional): Firestone ISO 95+ GL Any ¼” UltraPly TPO A, Fully Adhered NC Insulation (Optional): Firestone ISO 95+ GL or Resista Coverboard or Insulation (Top): Firestone ISOGARD HD or Resista ¼” UltraPly TPO, ReflexEON A, Fully Adhered Any ½” Construction: Classification: Recover Retains Existing UL Classification Rating Deck Type Insulation Assembly Insulation Minimum Thickness Maximum Slope Membranes Class, Type C/NC Existing Class A, B or C BUR (smooth surface or cap sheet) Coverboard: Firestone ISOGARD HD --½” 1/4” UltraPly TPO, ReflexEON A/B/C, Maintenance / Repair Maximum Slope Notes Class, Type 3” *DensDeck, ¼” A, Fully Adhered Firestone Fully Adhered Systems with UltraPly TPO SA membrane Membrane: Adhesive: Construction: Classification: UltraPly TPO SA (45 or 60 mil) Self Adhered New, Retrofit or Tear-off Class A Deck Type Insulation Assembly NC C* Insulation (Optional): Firestone ISO 95+ GL Barrier Board: DensDeck Insulation Minimum Thickness Any ¼” C/NC Insulation (Optional): Firestone ISO 95+ GL Barrier Board: DensDeck Any ¼” 3” A, Fully Adhered C/NC Insulation (Optional): Firestone ISO 95+ GL Coverboard: Firestone ISOGard HD Any 1” ½” A, Fully Adhered NC C* Insulation (Optional): Firestone ISO 95+ GL Coverboard: Firestone ISOGard HD Any ½” ¾” *DensDeck, ¼” A, Fully Adhered 8|P age February 2014 Firestone Fully Adhered Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: Deck Type C/NC C/NC UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) XR Bonding Adhesive @ 90 sq ft/gal New, Retrofit or Tear-off Class A Insulation Maximum Insulation Assembly Minimum Slope Thickness Insulation (Optional): Firestone ISO 95+ GL Any 1” Coverboard: G-P Gypsum DensDeck or DensDeck Prime ¼” Any Classified LWIC 2” 1” Notes Class, Type A, Fully Adhered A, Fully Adhered Firestone Fully Adhered Systems with UltraPly TPO XR Construction: Classification: Deck Type C/NC Recover Retain Existing Class A, B, or C rating Insulation Insulation Assembly Minimum Thickness Existing Class A, B or C BUR (smooth surface or cap sheet) --- Maximum Slope Notes Class, Type A/B/C, Maintenance / Repair 1” Firestone Fully Adhered (Hot Asphalt) Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: Deck Type NC C/NC UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) Hot asphalt New, Retrofit or Tear-off Class A Insulation Maximum Insulation Assembly Minimum Slope Thickness Notes Class, Type None --- 1” A, Fully Adhered Insulation (Optional): Firestone ISO 95+ GL Barrier Board: DensDeck Any ¼” 1” A, Fully Adhered Firestone Fully Adhered Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: NC C* UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) Firestone ISO Spray S or Firestone XR Stick Adhesive New, Retrofit or Tear-off Class A Insulation Maximum Insulation Assembly Minimum Slope Thickness Insulation (Optional): Firestone ISO 95+ GL, Any ¼” Resista, or ISOGARD HD NC C* Structural Concrete or Lightweight Concrete decks only --- ½” Insulation (Optional): Firestone ISO 95+ GL Barrier Board: DensDeck Any ¼” ½” Deck Type C/NC Notes Class, Type *DensDeck, ¼” A, Fully Adhered *DensDeck, ¼” A, Fully Adhered A, Fully Adhered 9|P age February 2014 Firestone Mechanically Attached Systems Membrane: UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum (80 mil) Construction: New, Retrofit or Tear-off Classification: Class A Insulation Deck Maximum Insulation Assembly Minimum Membrane Class, Type Type Slope Thickness A, Insulation (Optional): Firestone ISO 95+ GL or Any Mechanically Resista C/NC 4” Ultraply TPO ¼” Attached Coverboard: DensDeck A, Any NC --4” UltraPly TPO Mechanically ¼” Attached A, Insulation (Optional): Firestone ISO 95+ GL or Any Mechanically Resista NC 2” UltraPly TPO ½” Attached Coverboard: Firestone FiberTop B, C, E, or S C/NC Two layers of “VersaShield Underlayment” or “VersaShield FB-2S Insulation (Optional): Firestone ISO 95+ GL or Resista Coverboard: Firestone ISOGARD HD or Resista Any NC Insulation: Firestone ISO 95+ GL Coverboard: Firestone ISOGARD HD or Resista A, Mechanically Attached A, Mechanically Attached 1” UltraPly TPO ¾” UltraPly TPO and ReflexEON Any 1” ½” UltraPly TPO and ReflexEON Insulation: Firestone ISO 95+ GL Any ½” UltraPly TPO C/NC Two or more layers of Atlas "FR 50", mechanically fastened --- ½” UltraPly TPO C/NC Two layers “VersaShield Underlayment” or “VersaShield FB-2S Insulation: Firestone ISO 95+ GL ½” UltraPly TPO Insulation Minimum Thickness Maximum Slope Membrane Class, Type --Any ½” UltraPly TPO A, Mechanically Attached C/NC NC --- ½” --Any A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached Firestone Mechanically Attached Systems Deck Type C/NC Insulation Assembly Two layers “VersaShield FB-1S, preliminary attachment Insulation (Optional): Firestone ISO 95+ GL Firestone Mechanically Attached Recover Systems Membrane: UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum (80 mil) Construction: Recover Classification: Retain Existing Class A, B, or C rating Deck Insulation Assembly Insulation Maximum Notes Type Example: Base Layer Minimum Slope Class, Type Top Layer Thickness C/NC One layer of Atlas “FR 10” or “FR 11”, one layer --1” UltraPly TPO A/B/C, C/NC One layer of “VersaShield Underlayment” --- 1” UltraPly TPO C/NC Existing Class A, B or C BUR (smooth surface or cap sheet) Coverboard: Firestone ISOGARD HD --½” ½” UltraPly TPO and ReflexEON Maintenance / Repair A/B/C, Maintenance / Repair A/B/C, Maintenance / Repair 10 | P a g e February 2014 Firestone Mechanically Attached Systems with UltraPly TPO XR Membrane: UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) Construction: Recover Classification: Retain Existing Class A, B, or C rating Deck Insulation Assembly Insulation Maximum Type Example: Base Layer Minimum Slope Top Layer Thickness Existing: To maintain A, B or C classification, insulated C/NC or un-insulated Type G3 mineral surfaced cap sheet, --½” or APP modified bitumen membrane roofing system. Notes Class, Type A/B/C, Maintenance / Repair UL Internal Fire Ratings In order to determine the resistance of a building to internal sources of fire, Underwriters Laboratories has conducted extensive testing and classification of wall, floor/ceiling and roof/ceiling assemblies. UL classified assemblies are rated according to the time in hours the assembly will contain a fire and still maintain structural integrity. Testing is conducted in accordance with UL Standard 263 (ASTM E-119), which is recognized by all major building codes. Roof/Ceiling Assemblies are listed in the UL Fire Resistance Directory - Vol. 1 under the prefix “P” and are classified by hourly fire rating according to the type of protection used to contain a fire: Assembly P000 – P099 P200 – P299 P400 – P499 P500 – P599 P600 – P699 P700 – P799 P800 – P899 P900 – P999 Protection Used Concealed grid suspended ceiling Exposed grid suspended ceiling Metal lathe (plaster) ceiling Gypsum board ceiling Miscellaneous fireproofing Spray-Applied Resistive Material Spray-Applied Resistive Material Unprotected concrete or composite decks It should be noted that the roof membrane forms only a small part of the total roof/ceiling assembly. In order for a structure to qualify for a particular “P” Assembly or Roof Deck Construction, all materials used to construct the assembly (including roof decking, ceiling materials, light fixtures, duct work and structural support members) must be UL classified and installed as described in the appropriate UL Directories. The insulations listed with each of the following “P” Assemblies are not, in most cases, the only UL accepted insulations for that assembly. Consult the UL Fire Resistance Directory - Vol. 1 for “P” Assembly information and the UL Roofing Materials and Systems Directory for Roof Deck Construction information, or call Firestone Technical Services for additional accepted insulations. UL has indicated on page 8 of the 2008 Fire Resistance Directory - Vol. 1 that "Class A, B or C roof coverings consisting of hot mopped or cold applied bituminous materials or a roof covering material classified under 'Roofing Membranes' (CHCI) may be applied directly to the concrete or wood surface of floor designs being used as roofs without a reduction of fire resistance ratings." They further state on page 8 that "Roof insulation is to be carefully controlled relative to manufacturer, type and thickness as specified. Less than the specified thickness could result in higher temperatures on the roof covering while a greater thickness of insulation could cause earlier structural failure. Classified polystyrene insulation, with a density of 5 pcf or less, may be placed on concrete floors or structural concrete roofs without reducing the assembly rating. When …polyisocyanurate insulation is used over concrete in D 900 Series Designs, the unrestrained beam rating shall be increased by a minimum of ½ hour." Roof Deck Constructions are listed in the UL Roofing Materials and Systems Directory and are rated according to the interior flame spread of the assembly as compared to the flame spread of a typical built-up roof installed over a metal deck (UL 1256). Roof Deck Constructions may also be classified according to wind uplift performance. The fire rating of a UL Roof Deck Construction is similar to the Factory Mutual Class I internal fire (calorimeter) rating and they are deemed equivalent by the Model Building Code Agencies. 11 | P a g e February 2014 UL Roof Deck Constructions and “P” Assemblies Deck Constructions (Tested in accordance to UL 1256) Firestone UltraPly TPO 96/120 roofing systems are classified for use in the following Deck Construction: 1, 2, 9, 14, 120, 123, 158, 200, 219, 237, 260, 276, 289, 292, 325, 374, 411, 412, 413, 419, 421, 440, 441, 444, 457, and 458 Consult Roof Deck Constructions (TGKX) in the UL Roofing Materials and Systems Directory, your regional technical coordinator or the Firestone Codes Department for an acceptable insulation for use in these constructions. “P” Assemblies (Designs) Firestone TPO 96/120 roofing systems are classified for use in the following hourly P211, P214, P215, P216, P224, P225, P227, P229, P230, P231, P232, P235, P237, P405, P406, P407, P410, P411, P505, P507, P508, P509, P510, P511, P513, P514, P711, P712, P713, P717, P718, P719, P720, P722, P723, P724, P725, P726, P727, P733, P734, P735, P736, P737, P738, P739, P801, P802, P803, P804, P805, P810, P816, P817, P818, P819, P822, P823, P825, P826, P827, P902, P903, P904, P905, P911, P912, P913, P914, P915, P916, P917, P918, P919, P920, P921, P922, P923, P929, P930, P931. roof / ceiling designs. P241, P242, P246, P251, P519, P701, P708, P709, P728, P729, P730, P731, P811, P812, P813, P814, P906, P907, P908, P909, P924, P925, P926, P927, P259, P710, P732, P815, P910, P928, Consult Fire Resistance Ratings (BXUV) in the UL Fire Resistance Directory, your regional technical coordinator or the Firestone Codes Department for an acceptable insulation, thickness and additional requirements. NOTE: The accepted insulation must be used in a UL Class A, B or C rated roofing assembly. UL acceptable system (e.g., adhering EPDM to Perlite or Fiberglass) listed for "P" design may not be approved for installation and warranty by Firestone. Contact Firestone Specifications and/or your Firestone Regional Technical Coordinator concerning acceptance. Please refer to pages 4 through 6 of this Approval Guide to determine the appropriate insulation/membrane assembly. Factory Mutual General Information Factory Mutual Class 1 Approvals cover a wide range of testing of roofing products, including tests for fire resistance, corrosion resistance, fuel contribution and hail damage, Factory Mutual Approvals are known best for the uplift resistance, 1-60, 1-90, etc. afforded by an FM Approved roofing assembly: • • • FM 1-60 assemblies have been tested to withstand 60 psf air pressure applied for a period of one minute as well as one minute at the 30 and 45 psf levels. FM 1-90 assemblies have been tested to withstand 90 psf air pressure applied for a period of one minute as well as one minute at the 30, 45, 60 and 75 psf levels. Higher uplift ratings are possible based on the deck type and its attachment, fastener density and row spacing where applicable. When Factory Mutual 1-60 or 1-90 uplift ratings are specified, additional insulation attachment and reduced perimeter and corner batten (in-seam plate or batten for Reinforced Systems) spacing will/may be required. Consult the current edition of Factory Mutual Loss Prevention Data Sheets 1-28 and 1-29 for instructions for determining the required corner and perimeter dimensions and reduced spacing and increased fastener densities. Ground Roughness Definitions Ground Roughness B - Urban and suburban areas, well wooded areas or other terrain with numerous closely-spaced obstructions the size of single family dwellings or larger. Ground Roughness C - Open terrain with scattered obstructions of heights generally less than 30 ft. (9 m). This includes flat, open country and grasslands. Ground Roughness D - flat, unobstructed areas directly exposed to wind blowing over large bodies of water. This category should be used for areas extending inland from the shore a distance of 1500 ft. (460m) or ten times the height of the building or structure, whichever is greater. (1) Width of perimeter is 10% of the building width or 40% of the building height, whichever is smaller, but not less than 8.5 feet. Corner areas are square with side dimensions equal to the perimeter width, but the 10% lesser building dimension limit is not applied in determining the corner dimension. (2) Wind speeds are taken from Factory Mutual Loss Prevention Data Sheet 1-28 and are based on a 100 year mean recurrence interval. (3) Stone ballast shall be smooth stone, 1" to 2" nominal diameter, which meets the gradation requirements of standard size No. 3 for coarse aggregate per ASTM D448 (85% larger than 1” diameter). 12 | P a g e February 2014 Ballasted Systems Factory Mutual tests and rates only fully adhered and mechanically attached systems; Factory Mutual does accept the use of Ballasted Roof Systems on a job-to-job basis for FM insured clients. According to Mr. Edward J. Ward, Construction Standards Manager for Factory Mutual Research, “... the Factory Mutual system windstorm loss experience has been extremely favorable for single ply ballasted roof systems. When these roofs are installed in accordance with (Factory Mutual) Loss Prevention Data Sheet 1-29, they are equally acceptable to Factory Mutual approved roofs.” General Notations PLEASE NOTE: Not all FM-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. RoofNav® assemblies are summarized in the following tables; however, an assembly search should be conducted in order to confirm the attachment rates and requirements set for in the approval number. In all occasions, should a discrepancy occur between this guide and RoofNav, the published information located in the approval at www.roofnav.com should be adhered and utilized. Additionally, please be aware that the following assemblies typically are in reference to the field of the roof rating and attachment. Please refer to FM Global Loss Prevention Data Sheet 1-28 and 1-29 to determine the requirements for additional fastening requirements in the perimeter and corner. In all cases, when the project is actually Factory Mutual insured, please consult the FM agent assigned to the review of the project to ensure compliance. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. It is acceptable to use multiple layers of FM Approved insulation, mechanically secured through all layers, provided all of the following are true: • All layers are the same insulation; • The total insulation thickness is not greater than the maximum FM Approved thickness of the insulation; • The mechanical fastening and wind uplift rating are per the FM Approval of the top layer; and, • The roof cover/insulation/fastener combination is FM Approved. **Water Based Bonding Adhesive-P (WBBA-P) is the equivalent to Water Based Bonding Adhesive-S (WBBA-S).** Assemblies in red font are recent additions to the Code Approval Guide. Field/Corner/Perimeter Definitions 1. 2. 3. 4. 5. 6. 7. 8. 9. Zone 1 except Zone 2 if θ> 7°. Zone 2 except Zone 3 if θ≤ 7° and h > 60 ft (18 m). Zone 2 except Zone 3 if θ< 7° and h ≤ 60 ft (18 m). If a parapet height ≥ 3 ft (1 m) is provided around the perimeter of the roof with θ≤ 7°, treat Zone 3 as Zone 2. 7° = 1-1/2”:12” (125 mm/m); 10° = 2”:12” (167 mm); 27° = 6”:12” (500 mm/m); 45° = 12”;12” (1 m/m). Partially enclosed building multipliers for roofs are based only on openings affecting the top story. Value of “a”: a) For h ≤ 60 ft (18 m), “a” is the smaller of 0.1 times the building lesser plan dimension or 0.4 times h, and never less than 4% of the least horizontal plan dimension, or 3 ft (0.9 m). Zone 3 is a square with dimensions “a”. b) For h > 60 ft (18 m), “a” is 0.1 times the building lesser plan dimension, but not less than 3 ft (0.9 m). Zone 3 is an ell with dimensions “2a”. Value of “h”: a) For slopes ≤ 10°, h = eave height b) For slopes > 10°, h = mean roof height Value of “w” is based on the lesser plan dimension. 13 | P a g e February 2014 Roof Design Negative Pressure Multipliers Zones 1, 2, 3 for Flat and Gabled Roofs Apply multipliers to pressure values in Tables 3, 4, and 5, as appropriate. Partially Enclosed Building⁶ Mean Roof Height, h Roof Slope Enclosed Building Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 h≤ 60 ft (18 m); and when Θ ≤ 7° 1.0 1.68 2.53 1.31 1.99 2.85 h/w ≤ 1 for 60 < h < 90 ft (18 7° < θ ≤ 27° 0.92 1.59 2.36 1.23 1.91 2.67 < h < 27.4 m) 27° < θ ≤ 45° 1.0 1.17 1.17 1.31 1.48 1.48 When h/w > 1 for 60 ft < h < Θ ≤ 10° 1.34 2.10 2.86 1.65 2.42 3.18 90 ft (18 < h < 27.4 m) 10° < θ ≤ 27° 0.92 1.59 2.36 1.23 1.91 2.67 See Note 6 below 27° < θ ≤ 45° 1.0 1.17 1.17 1.31 1.48 1.48 h ≥ 90 ft (27.4 m) Θ ≤ 10° 1.0 1.57 2.14 1.23 1.80 2.37 See Note 6 below 10° < θ ≤ 27° 0.68 1.19 1.76 0.92 1.42 1.99 27° < θ ≤ 45° 0.75 0.87 0.87 0.98 1.11 1.11 Perimeter and Corner Treatment of Adjoining Buildings 14 | P a g e February 2014 Prescriptive Enhancement Options: Perimeter and Corner For all deck types, where roof covers are adhered to some combination of mechanically fastened insulation, cover board, or thermal barriers, prescriptive enhancements may be used for securement of the perimeter and corner areas, as long as one of the conditions below applies: The building is in a non-hurricane prone region where the design wind speed does not exceed 90 mph and the roof height does not exceed 75 ft (23 m). Note the roof height is limited to 30 ft (9.1 m) if the building is located in surface roughness exposure D (see DS 1-28) and the building is partially enclosed. • Or • The recommended field of roof rating needed per DS 1-28 does not exceed Class 1-75 (3.6 kPa). Or • The building is located in a non-hurricane prone area and the recommended field of the roof rating per Datasheet 1-28 does not exceed Class 1-90. For any of the three conditions above, increase the number of fasteners per board over the FM Approved field of the roof spacing by the following: • • • 50% minimum in the roof perimeter, but at least one fastener per 2 ft². (1 per 0.19 m²). It is not necessary to install fasteners closer than one per 1 ft² (1 per 0.09 m²). One fastener per 1 ft² (1 per 0.09 m2) in corner areas. Round up to the next whole number of fasteners, if necessary. Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System Uplift Deck Type Thermal Barrier Vapor Barrier System Insulation Assembly Membrane Options RoofNav Assembly Number 1-90 Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C Concrete (New or recover) DensDeck, ¼” minimum, 8 AP or HD fasteners and plates per 4’x8’ board DensDeck, ¼” minimum, 8 AP or HD fasteners and plates per 4’x8’ board DensDeck, ¼” minimum, 8 HD or Concrete Drive fasteners and plates per 4’x8’ board Primed thermal barrier with VForce SB Primer ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center UltraPly TPO, ReflexEON 294762-0-0 Primed thermal barrier with VForce SB Primer 2 Layers - ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center UltraPly TPO, ReflexEON 294764-0-0 Primed thermal barrier with VForce SB Primer UltraPly TPO, ReflexEON 294593-0-0 1-90 Concrete (New or recover) DensDeck, ¼” minimum, 8 HD or Concrete Drive fasteners and plates per 4’x8’ board Primed thermal barrier with VForce SB Primer ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center FiberTop C, E or S, ½”; or ISOGard HD, ½”; or DensDeck, 1/4”; or APA rated OSB, 7/16”, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center 2 Layers - ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center UltraPly TPO, ReflexEON 294633-0-0 1-525 Concrete (New or recover) None Primed substrate with V-Force SB Primer ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center UltraPly TPO, ReflexEON 294948-0-0 1-525 Concrete (New or recover) Concrete (New or recover) None Primed substrate with V-Force SB Primer Primed substrate with V-Force SB Primer 2 Layers - ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Stick at 12” on center DensDeck, DensDeck Prime, or SECUROCK AT ¼” min. ISO 95+ GL, 1.5” minimum, 4’x4’ boards, adhered with I.S.O. Twin Pack at 12” on center UltraPly TPO, ReflexEON 294949-0-0 UltraPly TPO, ReflexEON 295522-0-0 1-90 1-90 1-795 None 15 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – Standard UltraPly TPO New Construction, Concrete Deck, Adhesively Attached Insulation, Without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-555 Concrete 12” o.c. beads of ISO Spray S Adhesive UltraPly or ReflexEON membrane UltraPly Bonding Adhesive A 304517-0-0 1-330 Concrete Tapered ISO 95+ GL, .5” min. ISO 95+ GL, 1”-4” 4’x4’ boards ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive 223517-0-0 Concrete ISO 95+ GL, 1.5”-4”, 4’x4’ boards ISO Spray S, full application A 80684-0-0 1-360 Concrete ISO 95+ GL, 1.5”-4”, 4’x4’ boards Asphalt Attached, full application A 245813-0-0 1-480 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 8” o.c. beads of Twin Pack Adhesive A 223518-0-0 1-540 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards A 228481-0-0 1-570 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive 4” o.c. beads of Twin Pack Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive A 1-360 UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane A 223523-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-120 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive FiberTop, ½” minimum, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive UltraPly or ReflexEON membrane A 228477-0-0 1-120 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive 12” o.c. beads of I.S.O. Stick Adhesive UltraPly or ReflexEON membrane A 228479-0-0 1-120 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Fix Adhesive DensDeck, DensDeck Prime, or SECUROCK, ¼” minimum, 4’x4’ boards ISOGard HD, ½”, 4’x4’ boards 12” o.c. beads of I.S.O. Fix Adhesive UltraPly or ReflexEON membrane UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive Water Based Bonding Adhesive-S A 233376-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-255 Concrete ISO 95+ GL, 1.5” 12”, 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive DensDeck Prime or SECUROCK, ¼” min., 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane UltraPly or Single Ply LVOC Bonding Adhesive A 223524-0-0 16 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-495 Concrete Tapered ISO 95+ GL, .5” min, ISO 95+ GL 1.5”-8” DensDeck Prime, ¼” min., 4’x4’ boards 12” o.c. beads of Twin Pack, Fix II, Spray S, Stick Adhesive UltraPly or ReflexEON membrane UltraPly Bonding Adhesive A 346005-0-0 1-255 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of Twin Pack, Fix II, Spray S, Stick Adhesive 12” o.c. beads of Twin Pack Adhesive DensDeck Prime or SECUROCK, ¼” min., 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane A 223524-0-0 1-270 Concrete A 233376-0-0 A 233380-0-0 1-270 Concrete 12” o.c. beads of Twin Pack Adhesive 12” o.c. beads of I.S.O. Stick Adhesive ISO Spray S, full application UltraPly or ReflexEON membrane Concrete 12” o.c. beads of Twin Pack Adhesive 12” o.c. beads of I.S.O. Stick Adhesive ISO Spray S, full application ISOGard HD, ½”, 4’x4’ boards 1-270 ISO 95+ GL, 1.5” 12”, 4’x4’ boards ISO 95+ GL, 1.5”12”, 4’x4’ boards ISO 95+ GL, 1.5”-4” 4’x4’ boards A 80622-0-0 1-270 Concrete ISO 95+ GL, 1.5”4”, 4’x4’ boards Asphalt Attached, full application FiberTop, 1/2” minimum, 4’x4’ boards Asphalt Attached, full application UltraPly or ReflexEON membrane A 245808-0-0 1-375 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 8” o.c. beads of Twin Pack Adhesive DensDeck Prime or SECUROCK, ¼” min., 4’x4’ boards 8” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane A 223525-0-0 1-390 Concrete Tapered ISO 95+ GL, 1.5” minimum 8” o.c. beads of Twin Pack Adhesive DensDeck or SECUROCK, ¼” min., 4’x4’ boards 8” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane A 113754-0-0 1-390 Concrete ISO Spray S, full application UltraPly membrane A 135967-0-0 Concrete A 245811-0-0 Concrete Asphalt Attached, full application 12” o.c. beads of I.S.O. Stick Adhesive UltraPly or ReflexEON membrane 1-495 Asphalt Attached, full application 12” o.c. beads of I.S.O. Stick Adhesive DensDeck or SECUROCK, ¼” minimum, 4’x4’ boards DensDeck or SECUROCK, ¼” minimum, 4’x4’ boards APA Rated OSB, 7/16” minimum, 4’x4’ boards ISO Spray S, full application 1-390 ISO 95+ GL, 1.5”4”, 4’x4’ boards ISO 95+ GL, 1.5”4”, 4’x4’ boards ISO 95+ GL, 1.5”12”, 4’x4’ boards UltraPly or Single Ply LVOC Bonding Adhesive Water Based Bonding Adhesive Water Based Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly Bonding Adhesive A 228464-0-0 1-600 Concrete ISO 95+ GL, 1.5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive A 233379-0-0 ISOGard HD, ½”, 4’x4’ boards FiberTop, 1/2” minimum, 4’x4’ boards ISOGard HD, ½”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick Adhesive UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or Single Ply Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly or Bonding Adhesive 17 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With Coverboard Uplift Deck Type (Vapor Retarder) Insulation and Attachment Coverboard and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Cementitious Wood Fiber Tectum Plank ISO 95+ GL, 1.5”4”, 4’x4’ boards, 12” o.c. beads of I.S.O. Fix Adhesive UltraPly or ReflexEON membrane 112012-0-0 Concrete, SA Primer (MB Base SA) A 202799-0-0 1-465 Concrete, (SBS Poly/Glass Torch Base or SBS Smooth) ISO 95+ GL, 1.5”12”, 4’x4’ boards, 12” o.c. beads of Twin Pack Adhesive Tapered ISO 95+ GL, 1.5” minimum (Opt. Layer), 12” o.c. beads of Twin Pack Adhesive UltraPly, Water Based Bonding Adhesive-S or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive A 1-240 DensDeck or SECUROCK, ¼” minimum, 4’x4’ boards, 12” o.c. beads of I.S.O. Fix Adhesive None DensDeck, DensDeck Prime, ¼” minimum, 4’x4’ boards, 12” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane UltraPly Bonding Adhesive A 233200-0-0 UltraPly or ReflexEON membrane Firestone Fully Adhered Uplift Ratings New Construction, Steel, Vapor Barrier, Adhesively Attached Insulation Uplift Deck Type Vapor Barrier Insulation and Attachment Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Steel, 22-16 gauge, Grade C MB Base SA ISO 95+ GL, 1.5”-12”, 4’x4’ boards And DensDeck Prime or SECUROCK, 5/8” thick 12” o.c. beads of Twin Pack Adhesive DensDeck Prime or SECUROCK ¼” minimum 12” o.c. beads of Twin Pack Adhesive UltraPly membrane UltraPly Bonding Adhesive A 200893-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Steel, 22-16 gauge, Grade C Concrete ISO 95+ GL, 1.5”-12” 12 AP or HD fasteners per 4’x8’ board UltraPly or ReflexEON membrane UltraPly, Water Based Bonding or Single Ply LVOC Bonding Adhesive A 2113-0-0 Steel, 22-16 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 2”-12” 8 AP or HD fasteners per 4’x8’ board ISO 95+ GL, 1.5”-12” 18 AP or HD fasteners per 4’x8’ board Steel, 22-18 gauge, Grade C Concrete ISO 95+ GL, 1.5”-4” 24 AP fasteners per 4’x8’ board ISO 95+ GL, 2”-4” 20 Concrete Drive or HD fasteners per 4’x8’ board 1-90 1-120 1-180 1-120 HD fasteners only 2106-0-0 UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or Single Ply LVOC Bonding Adhesive A 191607-0-0 UltraPly or Single Ply LVOC Bonding Adhesive A 127787-0-0 UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly Bonding Adhesive A 233194-0-0 Water Based Bonding Adhesive (WBBA) A 296301-0-0 18 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-150 Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 2”-4” 20 AP fasteners per 4’x8’ board UltraPly membrane UltraPly Bonding Adhesive A 233195-0-0 ISO 95+ GL, 2”-12” 32 AP or HD fasteners per 4’x8’ board UltraPly or ReflexEON membrane UltraPly or Single Ply LVOC Bonding Adhesive A 228346-0-0 1-225 Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-75 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1”-12” Loose Laid FiberTop (C,E,S), 1/2” minimum 12 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane A 2063-0-0 1-75 Concrete ISO 95+ GL, 1.5”12” Loose Laid FiberTop (C,E,S), 1/2” minimum 12 HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane A 2061-0-0 1-90 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”12” Loose Laid DensDeck or SECUROCK 1/4” minimum 15 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly, Water Based or Single Ply LVOC Bonding Adhesive A 112795-0-0 1-90 Steel, 22-16 gauge, Grade C Loose Laid DensDeck or SECUROCK 1/4” minimum 12 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive A 209896-0-0 1-90 Concrete ISO 95+ GL, 1.5”-8” Optional: Iso 95+ GL (tapered), .5”-4” ISO 95+ GL, 1”-12” Loose Laid DensDeck or SECUROCK 1/4” minimum 18 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane A 2064-0-0 1-150 Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”12” Loose Laid A 200412-0-0 Loose Laid 25 AP or HD fasteners per 4’x8’ boards 32 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane ISO 95+ GL, 1.5”12” DensDeck or SECUROCK 1/4” minimum DensDeck or SECUROCK 1/4” minimum A 200414-0-0 1-90 Steel, 20-18 gauge, Grade C ISO 95+ GL, 1.5”6.5” Loose Laid APA rated OSB, 7/16” minimum 12 HailGard fasteners per 4’x8’ boards UltraPly or ReflexEON membrane A 136153-0-0 1-105 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”6.5” Loose Laid APA rated OSB, 7/16” minimum 20 HailGard fasteners per 4’x8’ boards UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly, Water Based or Single Ply LVOC Bonding Adhesive A 136151-0-0 1-210 UltraPly or ReflexEON membrane 19 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard Uplift Deck Type Insulation Insulation Attachment 1-150 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”12” Loose Laid 1-300 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”12” 1-90 Steel, 22-18 gauge, Grade C HailGard, 2”-4” Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number APA rated OSB, 7/16” minimum 16 AP or HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane A 77830-0-0 Loose Laid APA rated OSB, 7/16” minimum 32 HD fasteners per 4’x8’ boards UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive UltraPly or Single Ply LVOC Bonding Adhesive A 171664-0-0 13 HailGard fasteners per 4’x8’ boards None None UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive A 136363-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-105 Steel, 22-18 gauge, Grade C HailGard, 2”-4” 20 HailGard fasteners per 4’x8’ boards None None UltraPly or ReflexEON membrane UltraPly, Water Based or Single Ply LVOC Bonding Adhesive A 136362-0-0 1-165 Steel, 22-18 gauge, Grade C HailGard, 2”-4” 32 HD fasteners per 4’x8’ boards None None UltraPly or ReflexEON membrane UltraPly Single Ply LVOC Bonding Adhesive A 328832-0-0 1-300 Steel, 22-18 gauge, Grade C Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C HailGard, 2”-4” 32 HD fasteners per 4’x8’ boards Loose Laid None None UltraPly or ReflexEON membrane A 171662-0-0 ISOGard HD, ½” thickness 12 AP or HD fasteners per 4’x8’ boards 12” o.c. beads of Twin Pack Adhesive 12” o.c. beads of Twin Pack Adhesive 12” o.c. beads of Twin Pack Adhesive UltraPly or ReflexEON membrane UltraPly Single Ply LVOC Bonding Adhesive UltraPly Single Ply LVOC Bonding Adhesive UltraPly Single Ply LVOC Bonding Adhesive UltraPly Single Ply LVOC Bonding Adhesive UltraPly Single Ply LVOC Bonding Adhesive A 233370-0-0 A 233373-0-0 A 233196-0-0 A 230423-0-0 1-90 1-90 1-90 1-90 ISO 95+ GL, 1.5”-12” ISO 95+ GL, 1.5”-12” ISO 95+ GL, 1.5”-4” ISO 95+ GL, 1.5”-4” 16 AP or HD fasteners per 4’x8’ board 16 AP or HD fasteners per 4’x8’ board 16 AP or HD fasteners per 4’x8’ board ISOGard HD, ½” thickness DensDeck or DensDeck Prime, ¼” minimum ISO 95+ GL (tapered), 0.5”-4” UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane UltraPly or ReflexEON membrane 20 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Mechanically Attached Insulation, Without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Notes Exterior Fire Rating RoofNav Number 1-90 Steel, 22-16 gauge, Grade C Firestone ISO 95+ GL, 1.5”-8” thickness 12 AP or HD fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: 6 mil polyethylene vapor retarder direct to deck A 287981-0-0 1-120 Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C Firestone ISO 95+ GL, 2”-8” thickness 18 AP or HD fasteners and plates per 4’x8’ board 287915-0-0 20 AP or HD fasteners and plates per 4’x8’ board A 287937-0-0 Firestone ISO 95+ GL, 1.5”12” thickness 24 AP or HD fasteners and plates per 4’x8’ board A 287934-0-0 Firestone ISO 95+ GL, 2”-8” thickness 32 AP or HD fasteners and plates per 4’x8’ board Optional: 6 mil polyethylene vapor retarder direct to deck Optional: 6 mil polyethylene vapor retarder direct to deck Optional: 6 mil polyethylene vapor retarder direct to deck Optional: 6 mil polyethylene vapor retarder direct to deck A Firestone ISO 95+ GL, 2”-8” thickness Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287929-0-0 1-165 1-165 1-225 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Mechanically Attached Insulation, Without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Notes Exterior Fire Rating RoofNav Number 1-90 Concrete Firestone ISO 95+ GL, 1.5”4” thickness 12 HD or Concrete Drive fasteners and plates per 4’x8’ board Optional: Firestone ISO 95+ GL, 1.5”4” thickness A 287979-0-0 1-120 Concrete Firestone ISO 95+ GL, 2”-4” thickness 18 HD or Concrete Drive fasteners and plates per 4’x8’ board Optional: Firestone ISO 95+ GL, 1.5”4” thickness A 287910-0-0 1-165 Concrete Firestone ISO 95+ GL, 2”-4” thickness 20 HD or Concrete Drive fasteners and plates per 4’x8’ board Optional: Firestone ISO 95+ GL, 1.5”4” thickness A 287935-0-0 1-165 Concrete Firestone ISO 95+ GL, 1.5”4” thickness 24 HD or Concrete Drive fasteners and plates per 4’x8’ board Optional: Firestone ISO 95+ GL, 1.5”4” thickness A 287931-0-0 1-225 Concrete Firestone ISO 95+ GL, 2”-4” thickness 32 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”4” thickness A 287925-0-0 21 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift Deck Type Insulation Insulation Attachment Insulation (Top) Insulation (Top) Attachment Membrane Notes Exterior Fire Rating RoofNav Number 1-60 Steel, 22-16 gauge, Grade C 12 AP or HD fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5”4” thickness, or Optional: ISO 95+ GL (tapered), .5”4” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: 6 mil polyethylene A 288098-0-0 1-75 Steel, 22-16 gauge, Grade C 8 AP or HD fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5” Thickness or Optional: ISO 95+ GL (tapered), .5”4” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: 6 mil polyethylene A 288104-0-0 1-90 Steel, 22-16 gauge, Grade C Firestone ISO 95+ GL, 2.0”4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness Firestone ISO 95+ GL, 2.0”4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness Firestone ISO 95+ GL, 1.5”4” thickness 16 AP or HD fasteners and plates per 4’x8’ board 12” o.c. beads of I.S.O. Spray S Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 303978-0-0 1-150 Steel, 22-18 gauge, Grade C Firestone ISO 95+ GL, 1.5” Thickness or Optional: ISO 95+ GL (tapered), .5”4” thickness Firestone ISO 95+ GL, 1.5” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287963-0-0 Firestone ISO 95+ GL, 2.0”4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness 20 AP or HD fasteners and plates per 4’x8’ board Optional: 6 mil polyethylene Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift Deck Type Insulation Insulation Attachment Insulation Insulation (Top) Attachment Membrane Exterior Fire Rating RoofNav Number 1-60 Concrete 12 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5” Thickness or Optional: ISO 95+ GL (tapered), .5” -4” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288090-0-0 1-75 Concrete Firestone ISO 95+ GL, 1.5”4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness Firestone ISO 95+ GL, 2”-4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness 8 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5” Thickness or Optional: ISO 95+ GL (tapered), .5” -4” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288099-0-0 22 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Uplift Deck Type Insulation Insulation Attachment Insulation Insulation (Top) Attachment Membrane Exterior Fire Rating RoofNav Number 1-90 Concrete Firestone ISO 95+ GL, 1.5”4” Thickness 16 HD or Concrete Drive fasteners and plates per 4’x8’ board 12” o.c. beads of I.S.O. Spray S Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 303942-0-0 1-150 Concrete Firestone ISO 95+ GL, 1.5”4” Thickness Optional: ISO 95+ GL 1.5”-4” thickness 20 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5” Thickness or Optional: ISO 95+ GL (tapered), 1.5”-4” thickness Firestone ISO 95+ GL, 1.5”4 thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287939-0-0 Exterior Fire Rating RoofNav Number Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Insulation with Mechanically Attached Coverboard Uplift Deck Type Insulation And Attachment Coverboard Coverboard Attachment Membrane 1-75 Steel, 22-16 gauge, Grade C Firestone ISO 95+ GL, 1.5”-4” thickness; Loose Laid 15 AP or HD fasteners and plates per 4’x8’ board 1-90 Steel, 22-16 gauge, Grade C Firestone ISO 95+ GL, 1.5” thickness, Loose Laid DensDeck, 1/4” Minimum. SECUROCK, ½” Minimum FiberTop C, E or S, 1” thickness 1-90 Steel, 22-16 gauge, Grade C Firestone ISO 95+ GL, 1.5”-4” thickness, Loose Laid Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone ISOGard HD, ½”-1” thickness 16 AP or HD fasteners and plates per 4’x8’ board 12 AP or HD fasteners and plates per 4’x8’ board Notes Optional: 6 mil polyethylene A 287989-0-0 Optional: 6 mil polyethylene A 287998-0-0 Optional: 6 mil polyethylene A 287976-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Insulation with Mechanically Attached Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number 1-75 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness Loose Laid Loose Laid A 287996-0-0 1-90 Concrete Firestone ISO 95+ GL, 1.5”-4” Thickness Optional: ISO 95+ GL, 1.5” thickness Firestone ISO 95+ GL, 1.5”-4” thickness Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) 287986-0-0 Concrete 15 HD or Concrete Drive fasteners and plates per 4’x8’ board 16 HD or Concrete Drive fasteners and plates per 4’x8’ board A 1-90 DensDeck, 1/4” Minimum. SECUROCK, ½” Minimum FiberTop C, E or S, 1” thickness Firestone ISOGard HD, ½”-1” thickness 12 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287973-0-0 Loose Laid 23 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Re-Roof/New Construction, Concrete and Gypsum, Adhesive Attachment Insulation/Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number 1-105 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness FiberTop C, E, and S, .5”1” thickness. 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288014-0-0 1-135 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness None None Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288018-0-0 1-330 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness DensDeck, DensDeck Prime, or SECUROCK ¼” minimum 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288040-0-0 1-405 Concrete Firestone ISO 95+ GL, 1”-4” thickness ISOGARD HD ½”-1” thickness 12” o.c. with I.S.O. Spray S Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 304387-0-0 1-420 Concrete Firestone ISO 95+ GL, 1”-4” thickness ISOGARD HD ½”-1” thickness 12” o.c. with I.S.O. Spray S Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 304083-0-0 1-555 Concrete Firestone ISO 95+ GL, 1”-4” thickness None None Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 304071-0-0 1-585 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness None None Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288024-0-0 1-90 Gypsum Firestone ISO 95+ GL, 1.5”-4” thickness None None Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288022-0-0 1-90 Gypsum Firestone ISO 95+ GL, 1.5”-4” thickness Firestone ISOGard HD, ½”-1” thickness 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288032-0-0 1-90 Gypsum Firestone ISO 95+ GL, 1.5”-4” thickness 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with I.S.O. Spray S Adhesive per 4’x4’ board 12” o.c. with I.S.O. Spray S Adhesive per 4’x4’ board 12” o.c. with I.S.O. Spray S Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board 12” o.c. with Twin Pack Adhesive per 4’x4’ board DensDeck, DensDeck Prime, or SECUROCK ¼” minimum 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288044-0-0 24 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Uplift 1-90 Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number Gypsum Firestone ISO 95+ GL, 1.5”-4” thickness 12” o.c. with Twin Pack Adhesive per 4’x4’ board FiberTop C, E, and S, .5”1” thickness. 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288016-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Recover, Concrete Deck, Mechanically Attached Insulation, Without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Notes Exterior Fire Rating RoofNav Number 1-75 Concrete Firestone ISO 95+ GL, 1”-4” thickness Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) None A 287984-0-0 1-90 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”-4” thickness, direct to substrate A 287980-0-0 1-120 Concrete Firestone ISO 95+ GL, 2”-4” thickness 16 HD or Concrete Drive fasteners and plates per 4’x8’ board 12 HD or Concrete Drive fasteners and plates per 4’x8’ board 18 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”-4” thickness, direct to substrate A 287912-0-0 1-165 Concrete Firestone ISO 95+ GL, 2”-4” thickness 20 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”-4” thickness, direct to substrate A 287936-0-0 1-165 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness 24 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”-4” thickness, direct to substrate A 287933-0-0 1-225 Concrete Firestone ISO 95+ GL, 2”-4” thickness 32 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Optional: Firestone ISO 95+ GL, 1.5”-4” thickness, direct to substrate A 287926-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Recover, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift Deck Type Insulation Insulation Attachment Insulation (Top) Insulation (Top) Attachment Membrane Exterior Fire Rating RoofNav Number 1-150 Concrete Firestone ISO 95+ GL, 1.5”-8” thickness 20 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone ISO 95+ GL, 1.5”-4” thickness 12” o.c. beads of Twin Pack Adhesive, 4’x4’ boards Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287955-0-0 25 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Recover, Concrete Deck, Mechanically Attached Insulation/Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number 1-75 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness Loose Laid 15 HD or Concrete Drive fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287987-0-0 1-90 Concrete Firestone ISO 95+ GL, 1.5”-8” thickness Loose Laid DensDeck, 1/4” Minimum. SECUROCK, ½” minimum FiberTop C, E or S, 1” thickness 287997-0-0 Concrete Firestone ISO 95+ GL, 1.5”-4” thickness Loose Laid Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 1-90 16 HD or Concrete Drive fasteners and plates per 4’x8’ board 12 HD or Concrete Drive fasteners and plates per 4’x8’ board A 287974-0-0 Firestone ISOGard HD, ½”-1” thickness Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Recover, Steel Deck, Mechanically Attached Insulation/Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number 1-75 Steel, 22-18 gauge, Grade C Firestone ISO 95+ GL, .5”-1” minimum 16 AP or HD fasteners and plates per 4’x8’ board None None A 287982-0-0 1-75 Steel, 22-18 gauge, Grade C None None 15 AP or HD fasteners and plates per 4’x8’ board A 287990-0-0 1-90 Steel, 22-18 gauge, Grade C None None DensDeck, 1/4” Minimum. SECUROCK, ½” minimum FiberTop C, E or S, .5”1” thickness Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 287999-0-0 1-90 Steel, 22-18 gauge, Grade C None None A 287977-0-0 Firestone ISOGard HD, ½”-1” thickness 16 AP or HD fasteners and plates per 4’x8’ board 12 AP or HD fasteners and plates per 4’x8’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Recover, Various Deck Types, Adhesive Attachment Insulation/Coverboard Uplift 1-90 Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number Gypsum None None Firestone ISOGard HD, ½” thickness 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288036-0-0 Cementitious Woodfiber 288037-0-0 26 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane Uplift 1-90 Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Exterior Fire Rating RoofNav Number Gypsum None None DensDeck or SECUROCK, 1/4” Minimum. 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A 288053-0-0 Firestone ISOGard HD, ½” thickness 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A DensDeck or SECUROCK, 1/4” Minimum. 12” o.c. with Twin Pack Adhesive per 4’x4’ board Firestone UltraPly TPO SA (Single-Ply QuickPrime Primer to primed roof insulation) A Cementitious Woodfiber 1-315 1-315 Steel, 22-18 gauge, Grade C Concrete None Steel, 22-18 gauge, Grade C Concrete None None None 288054-0-0 288034-0-0 288033-0-0 288052-0-0 288051-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane New Construction, Steel or Concrete Deck, Insulation without Coverboard, UltraPly XR membrane Uplift Deck Type Insulation Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Steel, 22-16 gauge, Grade C Concrete ISO 95+ GL, 1.5”-4” thickness 16 AP or HD fasteners per 4’x8’ board UltraPly XR 100, 115, 135 membrane ISO Spray S or XR Stick, 12” on center A 289254-0-0 ISO 95+ GL, 1.5”-4” thickness ISO 95+ GL, 2”-4” thickness 16 HD or Concrete fasteners per 4’x8’ board 20 AP or HD fasteners per 4’x8’ board UltraPly XR 100, 115, 135 membrane UltraPly XR 100, 115, 135 membrane ISO Spray S or XR Stick, 12” on center A 289250-0-0 ISO Spray S or XR Stick, 6” on center A 292119-0-0 ISO 95+ GL, 2”-4” thickness ISO 95+ GL, 2”-4” thickness ISO 95+ GL, 2”-4” thickness 20 HD or Concrete fasteners per 4’x8’ board 32 HD or Concrete fasteners per 4’x8’ board 32 AP or HD fasteners per 4’x8’ board UltraPly XR 100, 115, 135 membrane UltraPly XR 100 or 115 membrane ISO Spray S or XR Stick, 6” on center A 289292-0-0 ISO Spray S or XR Stick, 4” on center A 289295-0-0 UltraPly XR 100, 115, 135 membrane ISO Spray S or XR Stick, 4” on center A 292137-0-0 1-90 1-165 1-165 Steel, 22-18 gauge, Grade C Concrete 1-285 Concrete 1-285 Steel, 22-18 gauge, Grade C Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete Deck, Insulation with Coverboard, UltraPly XR membrane Uplift Deck Type Insulation And Attachment 1-60 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12”, 16 AP or HD fasteners per 4’x8’ boards Coverboard FiberTop (C,E,S), 1/2”1” Thickness Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number Hot asphalt, full application UltraPly TPO XR 100 or 115 membrane XR Bonding Adhesive A 243484-0-0 27 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings Uplift Deck Type Insulation And Attachment 1-75 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12”, Loose Laid 1-90 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1”12”, Loose Laid 1-90 Concrete ISO 95+ GL, 1.5”-4”, Loose Laid 1-90 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12”, Loose Laid 1-90 Concrete ISO 95+ GL, 1.5”-4”, Loose Laid FiberTop E 1/2” minimum 1-90 Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12”, Loose Laid ISOGard HD, ½” minimum ISO 95+ GL, 1.5”-4”, 4’x8’ board OSB, 7/16” thickness 16 AP or HD fasteners per 4’x8’ boards 1-90 Concrete ISO 95+ GL, 1.5”-4”, 4’x8’ boards, OSB, 7/16” thickness 1-120 Concrete ISO 95+ GL, 2.0”-12”, 20 AP or HD fasteners per 4’x8’ boards DensDeck Prime or SECUROCK, ½” minimum 1-120 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-4”, 20 AP or HD fasteners per 4’x8’ boards DensDeck Prime or SECUROCK, ½” minimum 16 HD or concrete Drive fasteners per 4’x8’ boards Firestone I.S.O. Fix or Fix II, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 6” on center, 4’x4’ board Firestone I.S.O. Fix or Fix II, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 6” on center, 4’x4’ board 1-90 Coverboard DensDeck, 1/4” Minimum or SECUROCK, 1/2” Minimum. DensDeck Prime, 1/4” Minimum. SECUROCK, ½” minimum DensDeck Prime or SECUROCK, 1/4” Minimum. FiberTop (C,E,S), 1/2” minimum Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 15 AP or HD fasteners per 4’x8’ boards UltraPly TPO XR 100 or 115 membrane Water Based Bonding Adhesive - S A 243485-0-0 12 AP fasteners per 4’x8’ boards UltraPly TPO XR 100 or 115 membrane ISO Spray S or XR Stick, 12” on center A 243482-0-0 16 HD or concrete Drive fasteners per 4’x8’ boards UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 12” on center A 292001-0-0 16 AP fasteners per 4’x8’ boards UltraPly TPO XR 100 or 115 membrane XR Bonding Adhesive A 243483-0-0 16 HD or concrete Drive fasteners per 4’x8’ boards 15 AP or HD fasteners per 4’x8’ boards UltraPly TPO XR 100, 115, or 135 membrane UltraPly TPO XR 100, 115, or 135 membrane UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 12” on center A 291988-0-0 ISO Spray S or XR Stick, 12” on center A 320509-0-0 ISO Spray S or XR Stick, 12” on center A 291981-0-0 UltraPly TPO XR 100, 115, or 135 membrane UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 12” on center A 289274-0-0 ISO Spray S or XR Stick, 6” on center A 289300-0-0 UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 6” on center A 292145-0-0 28 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings Uplift Deck Type Insulation And Attachment Coverboard 1-165 Steel, 22-18 gauge, Grade C ISO 95+ GL, 2.0”-12”, 20 HD or AP fasteners per 4’x8’ boards ISOGard HD, ½” minimum 1-165 Concrete ISO 95+ GL, 2.0”-12”, 20 HD or Concrete fasteners per 4’x8’ boards ISOGard HD, ½” minimum 1-255 Concrete ISO 95+ GL, 2”– 4”, 32 HD or Concrete fasteners per 4’x8’ boards DensDeck Prime or SECUROCK, ½” minimum Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number Firestone I.S.O. Fix, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 6” on center, 4’x4’ board Firestone I.S.O. Fix, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 6” on center, 4’x4’ board Firestone I.S.O. Fix or Fix II, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 4” on center, 4’x4’ board UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 6” on center A 320536-0-0 UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 6” on center A 320464-0-0 UltraPly TPO XR 100, 115, or 135 membrane ISO Spray S or XR Stick, 4” on center A 289296-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhered Coverboard Only, UltraPly XR membrane Uplift Deck Type 1-465 Concrete 1-720 Concrete Coverboard DensDeck Prime or SECUROCK, ¼” thickness, 4’x4’ boards ISOGard HD, ½” thickness, 4’x4’ boards Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number Hot Asphalt UltraPly TPO XR 100 or 115 membrane XR Bonding Adhesive A 243447-0-0 4” o.c. bead spacing with ISO Fix/Fix II or ISO Stick/Stick Green UltraPly TPO XR 100 or 115 membrane XR Bonding Adhesive A 261317-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, UltraPly XR membrane Uplift Deck Type Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-840 1-720 1-945 1-975 Concrete Concrete Concrete Concrete UltraPly TPO XR 115 Ultraply TPO XR 115 or 135 UltraPly TPO XR 100, 115, or 135 UltraPly TPO XR 115 or 135 Water Based Bonding Adhesive-S XR Bonding Adhesive XR Spray S, full coverage Hot Asphalt A A A A 242960-0-0 242966-0-0 293219-0-0 243438-0-0 29 | P a g e February 2014 Firestone Fully Adhered Uplift Ratings New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR membrane Uplift Deck Type, Vapor Barrier Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-345 Concrete, with mopped vapor barrier* ISOGard HD, ½”-1” thickness, 4’x4’ boards Firestone I.S.O. Fix or Fix II, I.S.O. Spray S, I.S.O. Twin Pack, or I.S.O. Stick Insulation Adhesive, 12” on center, 4’x4’ board UltraPly TPO XR 100, 115, 135 ISO Spray S or XR Stick, full coverage A 292419-0-0 DensDeck Prime or 292418-0-0 SECUROCK, ¼” thickness, 4’x4’ boards *One or two plies of Firestone Type IV (4)M or Type VI(6)M Ply Felt or one ply of MB Base, SBS Base, SBS Polybase or SBS Premium Base fully adhered to structural deck with a full mopping of hot asphalt. Firestone Fully Adhered Uplift Ratings New Construction, Lightweight Insulated Concrete, UltraPly XR membrane Uplift Deck Type Lightweight Manufacturer Membrane 1-60 Concrete 1-420 Concrete 1-210 Concrete 1-180 Concrete Range II Elastizell Lightweight Insulating Concrete Range II Elastizell Lightweight Insulating Concrete Celcore MF Cellular Concrete with Celcore- HS Rheology Modifying Admixer, Wet cast 40 lbs/ft³ Celcore- HS Rheology Modifying Admixer, Wet cast 40 lbs/ft³ UltraPly or 115 UltraPly or 115 UltraPly or 115 TPO XR 100 membrane TPO XR 100 membrane TPO XR 100 membrane UltraPly TPO XR 100 or 115 membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number Water Based Bonding Adhesive - S XR Bonding Adhesive A 244666-0-244657 A 244665-0-244657 Water Based Bonding Adhesive - S A 244650-0-244646 XR Bonding Adhesive A 244648-0-244646 Firestone Fully Adhered Uplift Ratings Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, Without Coverboard Uplift Deck Type Insulation Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Gypsum ISO 95+ GL, 1” thickness, 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive UltraPly TPO membrane UltraPly or Single Ply LVOC Bonding Adhesive A 319860-0-0 Firestone Fully Adhered Uplift Ratings Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Coverboard Uplift Deck Type Insulation Insulation Attachment Coverboard Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Gypsum None None DensDeck or SECUROCK, ¼” minimum, 4’x4’ boards 12” o.c. beads of Twin Pack Adhesive UltraPly TPO membrane A 113400-0-0 1-90 Gypsum ISO 95+ GL, .5”12”, 4’x4’ boards 12” o.c. beads of I.S.O. Stick/Stick Green Adhesive DensDeck or DensDeck Prime, ¼” minimum, 4’x4’ boards 12” o.c. beads of I.S.O. Stick/Stick Green Adhesive UltraPly TPO membrane UltraPly, Water Based Bonding Adhesive-S/P or Single Ply LVOC Bonding Adhesive UltraPly, Water Based Bonding Adhesive-S/P or Single Ply LVOC Bonding Adhesive A 115286-0-0 30 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane New Construction, Steel, Mechanically Attached Insulation, Single Weld Uplift Deck Type Insulation and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Steel, 22-18 gauge, Grade E Steel, 22-16 gauge, Grade C Steel, 22-18 gauge, Grade E Steel, 22-18 gauge, Grade E Steel, 20-16 gauge, Grade C Steel, 22-16 gauge, Grade C Steel, 22-18 gauge, Grade E Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement UltraPly TPO or ReflexEON membrane, 10’ Sheet 12” o.c. HD fastener and HD or Barbed Seam Plate, Single weld A 3080-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement UltraPly TPO membrane, 10’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 170476-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement UltraPly TPO or ReflexEON membrane, 8’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 76731-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement or ISO 95+ GL (Tapered) 1.5”-4” UltraPly TPO or ReflexEON membrane, 10’ Sheet 12” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 76911-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement UltraPly TPO membrane, 10’ Sheet 6” o.c. HD fastener and HD or Barbed Seam Plate, Single weld A 166431-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement UltraPly TPO or ReflexEON membrane, 8’ Sheet 12” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 213747-0-0 ISO 95+ GL, 1.5”-12”, Preliminary Securement or ISO 95+ GL (Tapered) 1.5”-4” UltraPly TPO or ReflexEON membrane, 10’ Sheet 6” o.c. HD fastener and HD or Barbed Seam Plate, Single weld A 3081-0-0 ISO 95+ GL, 1”-12”, Preliminary Securement UltraPly TPO or ReflexEON membrane, 6’ 6” Sheet UltraPly TPO membrane, 8’ Sheet 6” o.c. HD fastener and HD Plate, Single weld A 3074-0-0 6” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 343455-0-0 UltraPly TPO 120 membrane, 10’ Sheet 6” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 343459-0-0 1-60 1-90 1-90 1-90 1-90 1-105 1-105 1-135 1-135 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement Firestone Mechanically Attached Systems Uplift Ratings New Construction, Steel, Insulation with Coverboard, Single Weld Uplift Deck Type Insulation and Attachment Coverboard and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1”-12”, Preliminary Securement DensDeck, DensDeck Prime, or SECUROCK, ¼” min. UltraPly TPO or ReflexEON membrane, 10’ Sheet A 264245-0-0 1-60 Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement ISOGard HD, ½” thickness UltraPly TPO or ReflexEON membrane, 10’ Sheet 12” o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 12” o.c. HD fastener and HD Seam Plate, Single weld A 266089-0-0 31 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings Uplift Deck Type Insulation and Attachment Coverboard and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-75 Steel, 22-18 gauge, Grade C DensDeck or SECUROCK, ¼” min. UltraPly TPO or ReflexEON membrane, 8’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 339004-0-0 1-75 Steel, 22-18 gauge, Grade C ISOGard HD, ½” thickness UltraPly TPO or ReflexEON membrane, 8’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 338538-0-0 1-90 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement ISO 95+ GL, 1”-12”, Preliminary Securement DensDeck or SECUROCK, ¼” min. UltraPly TPO membrane, 6’ 6” Sheet A 339174-0-0 1-90 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement ISOGard HD, ½” thickness. UltraPly TPO membrane, 6’ 6” Sheet 6” o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 12” o.c. HD fastener and HD Seam Plate, Single weld A 339172-0-0 1-105 Steel, 22-18 gauge, Grade C DensDeck or SECUROCK, ¼” min. UltraPly TPO membrane,10’ Sheet 6” o.c. HD fastener and HD Seam Plate, Single weld A 343411-0-0 1-105 Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement ISO 95+ GL, 1.5”-12”, Preliminary Securement. Optional top layer of ISO 95+ GL (tapered) .5”-4” Preliminary Securement ISOGard HD, ½” thickness. UltraPly TPO membrane,10’ Sheet 6” o.c. HD fastener and HD Seam Plate, Single weld A 343408-0-0 Firestone Mechanically Attached Systems Uplift Ratings New Construction, Concrete, Insulation with Coverboard, Single Weld Uplift Deck Type Insulation and Attachment Coverboard and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Concrete ISO 95+ GL, 1.5”12”, Loose Laid FiberTop C,E or S,½” min. DensDeck or SECUROCK, ¼” min. ISOGard HD, ½” thickness FiberTop C,E or S,½” min. DensDeck or SECUROCK, ¼” min. ISOGard HD, ½” thickness UltraPly TPO ReflexEON membrane, 10’ Sheet 12” o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld A 269752-0-0 6” o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld A 1-75 Concrete ISO 95+ GL, 1.5”12”, Loose Laid UltraPly TPO 120 or ReflexEON membrane, 10’ Sheet 269751-0-0 269750-0-0 269743-0-0 269742-0-0 269741-0-0 32 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings Recover, Metal Building, Insulation with Coverboard Uplift Deck Type Flute Filler Insulation and Attachment Coverboard and Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Standing/L ap Seam Roof (Insulated) ISO 95+ GL, 1” ISO 95+ GL, .5”-1” thickness ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment DensDeck/DensDeck Prime or SECUROCK, ¼” min. Preliminary Attachment ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment DensDeck/DensDeck Prime or SECUROCK, ¼” min. Preliminary Attachment ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment DensDeck/DensDeck Prime or SECUROCK, ¼” min. Preliminary Attachment ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment DensDeck/DensDeck Prime or SECUROCK, ¼” min. Preliminary Attachment ISOGard HD, ½” min. Preliminary Attachment FiberTop (C,E or S), ½” min. Preliminary Attachment DensDeck/DensDeck Prime or SECUROCK, ¼” min. Preliminary Attachment UltraPly TPO or ReflexEON membrane, 10’ sheet 12” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld A 305074-0-0 1-60 1-90 1-90 1-105 1-105 Standing/L ap Seam Roof (Insulated) ISO 95+ GL, 1” minimum Standing/L ap Seam Roof (Insulated) ISO 95+ GL, 1” minimum Standing/L ap Seam Roof (Insulated) ISO 95+ GL, 1” minimum Standing/L ap Seam Roof (Insulated) Standing/L ap Seam Roof (Insulated) ISO 95+ GL, 1” minimum ISO 95+ GL, 1” minimum ISO 95+ GL, .5”-1” thickness ISO 95+ GL, .5”-1” thickness ISO 95+ GL, .5”-1” thickness ISO 95+ GL, 1”-4” thickness ISO 95+ GL, .5”-1” thickness 305078-0-0 305080-0-0 UltraPly TPO or ReflexEON membrane, 6’ 6” sheet 12” o.c. with Firestone Purlin Fasteners and Metal Batten Strip, Wide Weld A 305058-0-0 305059-0-0 305060-0-0 UltraPly TPO or ReflexEON membrane, 8’ sheet 12” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld A UltraPly TPO or ReflexEON membrane, 10’ sheet UltraPly QuickSeam RMA Strips secured to purlins at 6” o.c. with Firestone Purlin Fasteners and Metal Batten Strip, Single Weld A 6” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld A UltraPly TPO 148 or ReflexEON membrane, 12’4” sheet 305221-0-0 305222-0-0 305226-0-0 305227-0-0 305228-0-0 265291-0-0 265293-0-0 265296-0-0 UltraPly TPO 148 or ReflexEON membrane, 12’4” sheet 6” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld A 305233-0-0 305234-0-0 305237-0-0 33 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings – UltraPly XR 100 and XR 115 Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld Uplift Deck Type Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Steel, Any thickness/class, Recover Steel, Any thickness, Class E, Recover Steel, Any thickness/class, Recover Steel, Any thickness/class, Recover UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 242937-0-0 UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 12” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 242946-0-0 UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 6” o.c. HD fastener and HD+ Seam Plate, Single weld A 242950-0-0 UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 6” o.c. HD+ fastener and HD+ Seam Plate, Single weld A 242951-0-0 1-90 1-90 1-135 Firestone Mechanically Attached Systems Uplift Ratings Recover, Concrete Deck, UltraPly TPO XR membrane, Single Weld Uplift Deck Type Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-60 Concrete, Recover UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 12” o.c. HD fastener and HD Seam Plate, Single weld A 242935-0-0 1-90 Concrete, Recover UltraPly TPO XR 100, 115, 135 membrane, 10’ Sheet 6” o.c. HD fastener and HD Seam Plate, Single weld A 242949-0-0 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift Deck Type Insulation and Attachment Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-90 Steel, 22-16 gauge, Grade C Steel, 22-16 gauge, Grade C ISO 95+ GL, 1.5”-12” Thickness None A 250651-0-0 FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck or SECUROCK, ¼” min. None UltraPly TPO or ReflexEON membrane, Single weld UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System ISO 95+ GL, 1.5”-12” Thickness 6 HD fasteners and Invisiweld Plates per 4’x8’ board 6 HD fasteners and Invisiweld Plates per 4’x8’ board Invisiweld System A 277975-0-0 1-90 1-90 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness 1-90 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. 277978-0-0 277977-0-0 6 HD or Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board 6 HD Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 250819-0-0 UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 251831-0-0 251817-0-0 251833-0-0 34 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Uplift Deck Type Insulation and Attachment Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-120 Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12” Thickness None A 254071-0-0 FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. None UltraPly TPO or ReflexEON membrane, Single weld UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System ISO 95+ GL, 1.5”-12” Thickness 8 HD fasteners and Invisiweld Plates per 4’x8’ board 8 HD fasteners and Invisiweld Plates per 4’x8’ board Invisiweld System A 278050-0-0 1-120 1-120 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness 1-120 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness 1-150 1-150 Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12” Thickness ISO 95+ GL, 1.5”-12” Thickness 1-150 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness 1-150 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness 1-210 1-210 Steel, 22-18 gauge, Grade C Steel, 22-18 gauge, Grade C ISO 95+ GL, 1.5”-12” Thickness ISO 95+ GL, 1.5”-12” Thickness FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. None FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. None FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. None FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck or SECUROCK, ¼” min. 278052-0-0 278051-0-0 8 HD or Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board 8 HD Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254075-0-0 UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254077-0-0 12 HD fasteners and Invisiweld Plates per 4’x8’ board 12 HD fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld UltraPly TPO or ReflexEON membrane, Single weld 254076-0-0 254078-0-0 Invisiweld System A 253954-0-0 Invisiweld System A 254054-0-0 254053-0-0 254055-0-0 12 HD or Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board 12 HD Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board 16 HD fasteners and Invisiweld Plates per 4’x8’ board 16 HD fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254056-0-0 UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254058-0-0 254057-0-0 254059-0-0 UltraPly TPO or ReflexEON membrane, Single weld UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254090-0-0 Invisiweld System A 278065-0-0 278067-0-0 278066-0-0 35 | P a g e February 2014 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Uplift Deck Type Insulation and Attachment Coverboard Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-210 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness None UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254112-0-0 1-210 Concrete – New and Recover ISO 95+ GL, 1.5”-12” Thickness FiberTop (C,E or S), ½” min. ISOGard HD, ½” min. DensDeck/Dens Deck Prime, or SECUROCK, ¼” min. 16 HD or Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board 16 HD Concrete Drive fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Invisiweld System A 254117-0-0 254115-0-0 254119-0-0 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Recover, Metal Building, Invisiweld System, Induction Welded Uplift Deck Type Flute Filler Insulation Attachment Membrane Membrane Attachment Exterior Fire Rating RoofNav Assembly Number 1-105 Steel – Standing Seam ISO 95+ GL, 1”-4” thickness ISO 95+ GL, 1.5”-4” thickness, 5 HD fasteners and Insulation Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Induction Welded A 253893-0-0 1-105 Steel – Standing Seam ISO 95+ GL, 1”-4” thickness ISOGard HD, ½” thickness, 5 HD fasteners and Insulation Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Induction Welded A 253890-0-0 1-105 Steel – Standing Seam ISO 95+ GL, 1”-4” thickness FiberTop, ½”-1” thickness, 5 HD fasteners and Insulation Plates per 4’x8’ board UltraPly TPO or ReflexEON membrane, Single weld Induction Welded A 253897-0-0 1-105 Steel – Standing Seam ISO 95+ GL, 1”-4” thickness DensDeck/DensDeck Prime, or SECUROCK, ¼” min., 5 HD fasteners and Insulation Plates per 4’x8’ board 6” on center Purlin fastener and Invisiweld Plate, 120” row spacing 6” on center Purlin fastener and Invisiweld Plate, 120” row spacing 6” on center Purlin fastener and Invisiweld Plate, 120” row spacing 6” on center Purlin fastener and Invisiweld Plate, 120” row spacing UltraPly TPO or ReflexEON membrane, Single weld Induction Welded A 253900-0-0 Factory Mutual Ballast Guidelines FM RECOMMENDED BALLAST WEIGHT (LB/SQ FT) FOR ROOF FIELD/PERIMETERS/CORNERS Ground Roughness B ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 89 10/12/15 >89 ≤ 130 12/15/18 >130 - ? See Note 1 Steel or pre-cast panel deck with ≤ 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 60 >0 ≤ 60 10/12/15 12/15/15 >60 ≤ 89 >60 ≤ 89 12/15/15 12/15/18 >89 - ? >89 - ? See Note 1 See Note 1 110 mph Roof Height Ballast weights >0 ≤ 30 12/15/15 >30 ≤ 55 12/15/18 >55 - ? See Note 36 | P a g e February 2014 Ground Roughness B ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 89 10/10/12 >89 ≤ 130 12/12/15 >130 ≤ 220 12/15/18 >220 -? See Note 1 Steel or pre-cast panel deck with > 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 60 >0 ≤ 60 10/10/12 12/12/12 >60 ≤ 89 >60 ≤ 89 12/12/12 12/12/15 >89 ≤ 150 > 89 - ? 12/15/18 See Note 1 >150 - ? See Note 1 110 mph Roof Height Ballast weights >0 ≤ 30 12/12/12 >30 ≤ 55 12/12/15 >55 ≤ 89 12/15/18 > 89 - ? See Note 1 Ground Roughness B ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 89 10/10/10 >89 ≤ 130 12/12/15 >130 ≤ 220 12/15/18 >220 - ? See Note 1 Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 60 >0 ≤ 60 >0 ≤ 30 10/10/10 10/12/12 10/12/12 >60 ≤ 89 >60 ≤ 89 >30 ≤ 55 10/12/12 12/12/15 12/12/15 >89 ≤ 140 >89 - ? >55 ≤ 89 12/15/18 See Note 1 12/15/18 >140 - ? >89 - ? See Note 1 See Note 1 Ground Roughness B ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 89 10/10/10 >89 ≤ 130 12/12/12 >130 ≤ 220 12/12/15 >220 -500 15/15/18 Cementitious Wet Fill (Concrete) deck with > 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 60 >0 ≤ 60 >0 ≤ 30 10/10/10 10/10/12 10/10/12 >60 ≤ 89 >60 ≤ 89 >30 ≤ 55 10/10/12 12/12/12 12/12/12 >89 ≤ 140 > 89 ≤ 165 >55 ≤ 89 12/12/15 15/15/18 12/12/15 >140 - 350 >165 - ? > 89 - ? 15/15/18 See Note 2 See Note 2 Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater. Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater. Ground Roughness C ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 25 10/12/15 >25 ≤ 75 12/15/15 >75 ≤ 89 12/15/18 >89 - ? See Note 1 Steel or pre-cast panel deck with ≤ 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 15 >0 ≤ 15 10/12/15 12/15/15 >15 ≤ 45 >15 ≤ 35 12/15/15 12/15/18 >45 ≤ 89 >35 - ? 12/15/18 See Note 1 >89 - ? See Note 1 110 mph Roof Height Ballast weights >0 ≤ 15 12/12/15 >15 - ? See Note 1 Ground Roughness C ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 25 10/10/12 >25 ≤ 75 12/12/12 >75 ≤ 89 12/12/15 >89 ≤ 90 12/15/18 >90 - ? See Note 1 Steel or pre-cast panel deck with > 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 15 >0 ≤ 15 10/10/12 12/12/12 >15 ≤ 45 >15 ≤ 35 12/12/12 12/12/15 >45 ≤ 89 >35 ≤ 70 12/12/15 12/15/18 >89 - ? >70 - ? See Note 1 See Note 1 110 mph Roof Height Ballast weights >0 ≤ 15 12/12/15 >15 ≤ 30 12/15/18 >30 - ? See Note 1 Ground Roughness C ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 25 10/10/10 >25 ≤ 75 10/12/12 >75 ≤ 89 12/12/15 >89 ≤ 90 12/15/18 Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 15 >0 ≤ 15 >0 ≤ 15 10/10/10 10/12/12 12/12/15 >15 ≤ 45 >15 ≤ 35 >15 ≤ 30 10/12/12 12/12/15 12/15/18 >45 ≤ 89 >35 ≤ 70 >30 - ? 12/12/15 12/15/18 See Note 1 >89 - ? >70 - ? See Note 1 See Note 1 37 | P a g e February 2014 Ground Roughness C ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 25 10/10/10 >25 ≤ 75 10/10/12 >75 ≤ 89 12/12/12 >89 ≤ 90 12/12/15 >90 ≤ 275 15/15/18 Cementitious Wet Fill (Concrete) deck with > 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 15 >0 ≤ 15 >0 ≤ 15 10/10/10 10/10/12 12/12/12 >15 ≤ 45 >15 ≤ 35 >15 ≤ 30 10/10/12 12/12/12 12/12/15 >45 ≤ 89 >35 ≤ 70 >30 ≤ 89 12/12/12 12/12/16 15/15/18 >89 ≤ 165 >70 ≤ 89 >89 - ? 15/15/18 15/15/18 See Note 2 >165 - ? >89 - ? See Note 2 See Note 2 Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater. Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater. Ground Roughness D ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 30 12/15/15 >30 ≤ 89 12/15/18 >89 - ? See Note 1 Steel or pre-cast panel deck with ≤ 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 15 >0 ≤ 15 12/15/15 12/15/18 >15 ≤ 50 >15 - ? 12/15/18 See Note 1 >50 - ? See Note 1 110 mph Roof Height Ballast weights N/A See Note 1 Ground Roughness D ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 30 12/12/12 >30 ≤ 89 12/12/15 >89 - ? See Note 1 Steel or pre-cast panel deck with > 36” parapet 90 mph 100 mph Roof Height Ballast Roof Height Ballast weights weights >0 ≤ 15 >0 ≤ 15 12/12/12 12/12/15 >15 ≤ 50 >15 ≤ 35 12/12/15 12/15/18 >50 ≤ 89 >35 - ? 12/15/18 See Note 1 >89 - ? See Note 1 110 mph Roof Height Ballast weights N/A See Note 1 Ground Roughness D ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 30 10/12/12 >30 ≤ 89 12/12/15 >89 - ? See Note 1 Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 15 >0 ≤ 15 10/12/12 12/12/15 N/A See Note 1 >15 ≤ 50 >15 ≤ 35 12/12/15 12/15/18 >50 ≤ 89 >35 - ? 12/15/18 See Note 1 >89 - ? See Note 1 Ground Roughness D ≤85 mph Roof Height Ballast (ft) weights >0 ≤ 30 10/10/12 >30 ≤ 89 12/12/12 >89 ≤ 165 15/15/18 >165 - ? See Note 2 Cementitious Wet Fill (Concrete) deck with > 36” parapet 90 mph 100 mph 110 mph Roof Height Ballast Roof Height Ballast Roof Height Ballast weights weights weights >0 ≤ 15 >0 ≤ 15 >0 ≤ 45 10/10/12 12/12/12 15/15/18 >15 ≤ 50 >15 ≤ 35 >45 - ? 12/12/12 12/12/15 See Note 2 >50 ≤ 89 >35 ≤ 89 12/12/15 15/15/18 >89 ≤ 90 >89 - ? 15/15/18 See Note 2 >90 - ? See Note 2 Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater. Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater. 38 | P a g e February 2014