UltraPly™ TPO Roof Systems - Firestone Building Products

advertisement
UltraPly™ TPO Roof Systems
Underwriters Laboratories (UL)
UL Roof Deck Constructions and “P” Assemblies
Factory Mutual Approvals (FM)
1|P age
February 2014
Table of Contents
Underwriters Laboratories (UL) External Fire Ratings ............................................................ 5
UL assembly numbers change frequently due to the addition of newly approved assemblies.
For this reason the listed assemblies do not have associated assembly numbers, but all are
approved assemblies with UL. Please use the link below or contact your Building Services
Advisors for the associated assembly numbers. You will look for the listed “Type” then the
listed “Class” and search for the associated assembly. ................................................................................ 7
Firestone V-Force Vapor Barrier System ............................................................................................................. 7
Firestone Fully Adhered Systems ........................................................................................................................... 7
Firestone Fully Adhered Systems ........................................................................................................................... 8
Firestone Fully Adhered Systems with UltraPly TPO SA membrane ......................................................... 8
Firestone Fully Adhered Systems with UltraPly TPO XR ................................................................................ 9
Firestone Fully Adhered Systems with UltraPly TPO XR ................................................................................ 9
Firestone Mechanically Attached Systems ........................................................................................................ 10
Firestone Mechanically Attached Systems ........................................................................................................ 10
Firestone Mechanically Attached Recover Systems ...................................................................................... 10
Firestone Mechanically Attached Systems with UltraPly TPO XR ............................................................. 11
UL Internal Fire Ratings .................................................................................................. 11
UL Roof Deck Constructions and “P” Assemblies ........................................................................................... 12
Factory Mutual General Information.................................................................................. 12
Ground Roughness Definitions .............................................................................................................................. 12
Ballasted Systems ...................................................................................................................................................... 13
General Notations ...................................................................................................................................................... 13
Field/Corner/Perimeter Definitions ...................................................................................................................... 13
Perimeter and Corner Treatment of Adjoining Buildings ............................................................................ 14
Prescriptive Enhancement Options: Perimeter and Corner ....................................................................... 15
Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System ................................. 15
Firestone Fully Adhered Uplift Ratings – Standard UltraPly TPO ............................................ 16
New Construction, Concrete Deck, Adhesively Attached Insulation, Without Coverboard............ 16
New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard .................. 16
New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard .................. 16
New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With
Coverboard ................................................................................................................................................................... 18
New Construction, Steel, Vapor Barrier, Adhesively Attached Insulation ............................................ 18
New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard .... 18
New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard .... 19
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 19
2|P age
February 2014
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 20
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard .......... 20
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane ..................................... 21
New Construction, Steel Deck, Mechanically Attached Insulation, Without Coverboard ............... 21
New Construction, Concrete Deck, Mechanically Attached Insulation, Without Coverboard........ 21
New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached
Insulation....................................................................................................................................................................... 22
New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached ....... 22
Insulation....................................................................................................................................................................... 22
New Construction, Steel Deck, Insulation with Mechanically Attached Coverboard ........................ 23
New Construction, Concrete Deck, Insulation with Mechanically Attached Coverboard ................ 23
Re-Roof/New Construction, Concrete and Gypsum, Adhesive Attachment
Insulation/Coverboard.............................................................................................................................................. 24
Recover, Concrete Deck, Mechanically Attached Insulation, Without Coverboard ........................... 25
Recover, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation ..... 25
Recover, Concrete Deck, Mechanically Attached Insulation/Coverboard ............................................. 26
Recover, Steel Deck, Mechanically Attached Insulation/Coverboard..................................................... 26
Recover, Various Deck Types, Adhesive Attachment Insulation/Coverboard .................................... 26
Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane .................... 27
New Construction, Steel or Concrete Deck, Insulation without Coverboard, UltraPly XR
membrane ..................................................................................................................................................................... 27
New Construction, Steel or Concrete Deck, Insulation with Coverboard, UltraPly XR membrane
.......................................................................................................................................................................................... 27
New Construction, Concrete Deck, Adhered Coverboard Only, UltraPly XR membrane ................ 29
New Construction, Concrete Deck, UltraPly XR membrane ....................................................................... 29
New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR
membrane ..................................................................................................................................................................... 30
New Construction, Lightweight Insulated Concrete, UltraPly XR membrane ..................................... 30
Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, Without Coverboard...... 30
Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Coverboard ............ 30
Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane .......... 31
New Construction, Steel, Mechanically Attached Insulation, Single Weld ........................................... 31
New Construction, Steel, Insulation with Coverboard, Single Weld....................................................... 31
New Construction, Concrete, Insulation with Coverboard, Single Weld ............................................... 32
Recover, Metal Building, Insulation with Coverboard .................................................................................. 33
Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld .............................................................. 34
3|P age
February 2014
Recover, Concrete Deck, UltraPly TPO XR membrane, Single Weld ...................................................... 34
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 34
Invisiweld System, Induction Welded ................................................................................................................ 34
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 35
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System ......................... 36
Recover, Metal Building, Invisiweld System, Induction Welded .............................................................. 36
Factory Mutual Ballast Guidelines ..................................................................................... 36
Ground Roughness B ................................................................................................................................................ 36
Ground Roughness C ................................................................................................................................................ 37
Ground Roughness D ................................................................................................................................................ 38
4|P age
February 2014
Underwriters Laboratories (UL) External Fire Ratings
All regional building codes and most local building code officials require that roofing systems meet minimum performance
requirements when exposed to external fire sources. The accepted method for measuring external fire resistance is ASTM E-108.
This test standard, and closely related standards such as Underwriters Laboratories UL-790 and Uniform Building Code 15-2, is
used to determine the ability of a roof system to hinder the horizontal spread or vertical penetration of an external fire source. In
accordance with these standards, all classified roof covering assemblies fall into one of the three following categories.1
•
CLASS A: Includes roof coverings which are effective against severe fire exposures
•
CLASS B: Includes roof coverings which are effective against moderate fire exposures
•
CLASS C: Includes roof coverings which are effective against light fire exposures
For insulated assemblies over non-combustible roof decks, any classified roofing assembly may be installed over a new roof deck, an
existing roof deck or over an existing roofing assembly. Underwriters Laboratories states that “any classified roofing system may be
applied over a pre-existing roof system (Class A, B, C, verifiable or not) of the same deck type and establishes for that roof the
classification of the new system”. Also, an assembly classified over a combustible deck may be installed over an existing noncombustible deck and establish for the assembly the rating of the new system. A non-combustible deck rated assembly must be
tested and classified over a combustible deck in order to obtain the desired classification of the new assembly. Total insulation
thickness of combined existing and new roofing systems may not exceed the total maximum allowable for the new roofing system,
and non-insulated systems are not intended for use over insulated systems.
Noncombustible Roof Decks (NC): Steel, Concrete, Poured Gypsum – require testing for horizontal spread of flame.
Combustible Roof Decks (C): Wood, Plywood, Tectum – require testing for both horizontal spread and vertical penetration of flame.
The class of roof covering required by each regional building code depends upon many factors, including the use and location of the
building and the type of construction. The local building authority should always be consulted as to what the roofing assembly
classification will need to be for each roofing project.
It should be noted that these classifications apply to roofing assemblies, and NOT the roofing membrane. A roofing membrane
that is classified as part of a Class A assembly when installed over a particular insulation may not qualify as part of a Class A
assembly with another insulation.
The “UL Item Number” in the following listings has been added as a service to those who have the UL Building Materials Directory. It
identifies the UL listing from which our Code Approval Guide listing derives (e.g., “A,FA,23” means Class A, Fully Adhered, item
number 23; “B,MA,04” means Class B, Mechanically Attached, item number 04, etc.).
General Notations
•
•
•
•
•
PLEASE NOTE: Not all UL-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield
Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and
attachment for the warranty desired must be followed.
If a discrepancy occurs between this guide and UL Certifications, the published information located in the UL Certifications Directory at
www.ul.com should be adhered and utilized.
Noncombustible decks Classifications are acceptable for use over combustible (15/32” minimum plywood) decks when 1/2” gypsum board or
¼” DensDeck® are used directly over the deck with all joints staggered 6” minimum from plywood joints.
The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for
approval of assembly for warranty purposes.
HailGard Insulation is an acceptable alterative to all insulations in the following Classifications except where DensDeck is stated.
**Water Based Bonding Adhesive –P (WBBA-P) is an equivalent to Water Based Bonding Adhesive-S (WBBA-S).**
Assemblies in red font are recent additions to the Code Approval Guide.
1
Underwriters Laboratories Roofing Materials and Systems Directory, January, 2008, page 1.
5|P age
February 2014
Verify the included assemblies in the charts below with the
associated Firms (UL, FM, etc). Not all of the information
included in the RoofNav assemblies will be listed in the charts
below.
Verify that all assemblies meet Firestone Building Products
warranty requirements with the associated regions technical
team.
UL website:
FM Website:
UL Online Certifications Directory
www.RoofNav.com
6|P age
February 2014
UL assembly numbers change frequently due to the addition of
newly approved assemblies. For this reason the listed assemblies
do not have associated assembly numbers, but all are approved
assemblies with UL. Please use the link below or contact your
Building Services Advisors for the associated assembly numbers.
You will look for the listed “Type” then the listed “Class” and search
for the associated assembly.
http://database.ul.com/cgibin/XYV/template/LISEXT/1FRAME/showpage.html?name=TGFU.R9516&ccnshorttitle=Roofing+Systems&o
bjid=1074351895&cfgid=1073741824&version=versionless&parent_id=1073993597&sequence=1
Firestone V-Force Vapor Barrier System
Adhesive:
UltraPly Bonding Adhesive, Single Ply LVOC Bonding Adhesive or Water Based Bonding
Adhesive S
Construction:
New or Tear-off
Classification:
See Note 1 Below
Deck
Vapor Barrier
Roofing System
Maximum Slope
Class, Type
NC
“V-Force”,
Any Insulated UL Classified modified bitumen system,
(See Note 1)
A/B/C, Mechanically
(See
self adhered
BUR system, EPDM, or TPO membrane system.
Attached or Fully
Note 1)
Insulation may be adhered with Firestone "I.S.O. Twin
Adhered
Pack", “I.S.O Stick" or "I.S.O. Spray S".
Note 1: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system,
currently limited to a noncombustible deck.
Firestone Fully Adhered Systems
Membrane:
Adhesive:
Construction:
Classification:
Deck
Type
UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum
(80 mil)
UltraPly Bonding Adhesive, Single Ply LVOC Bonding Adhesive or Water Based Bonding Adhesive S
New, Retrofit or Tear-off
Class A
Insulation
Maximum
Insulation Assembly
Minimum
Membranes
Class, Type
Slope
Thickness
Insulation (Optional): Firestone ISO 95+ GL or
Resista
Barrier Board: DensDeck
Any
¼”
2-½”
UltraPly TPO
A, Fully
Adhered
Any Classified LWIC or structural Concrete
Any
2-½”
UltraPly TPO
A, Fully
Adhered
C/NC
Insulation (Optional): Firestone ISO 95+ GL
Barrier Board: DensDeck
Any
¼”
2”
UltraPly TPO
A, Fully
Adhered
Insulation (Optional): Firestone ISO 95+ GL or
Resista or FiberTop B, C, E, or S
Barrier Board: DensDeck
Any
C/NC
1-½”
ReflexEON
A, Fully
Adhered
Any
7/16”
1-¼”
UltraPly TPO
A, Fully
Adhered
--Any
½”
UltraPly TPO
A, Fully
Adhered
--Any
½”
UltraPly TPO
A, Fully
Adhered
Any
½”
½”
Platinum
membrane
w/WBBA only
A, Fully
Adhered
C/NC
NC
NC
C/NC
C/NC
C/NC
Insulation: Firestone ISO 95+ GL or Resista
Coverboard: Oriented Strand Board (OSB)
Slip Sheet: 2 layers VersaShield Underlayment or
VersaShield FB-2S
Insulation: Firestone ISO 95+ GL
Slip Sheet: 2 layers VersaShield FB-1S
Insulation: Firestone ISO 95+ GL, mechanically
attached
Insulation: Firestone ISO 95+ GL
Coverboard: Firestone Resista or Firestone ISOGard
HD
¼”
7|P age
February 2014
Firestone Fully Adhered Systems
Deck
Type
NC
NC
Insulation Assembly
Insulation (Optional): Firestone ISO 95+ GL or
Resista
Coverboard: Firestone FiberTop B, C, E or S
Insulation (Optional): Firestone ISO 95+ GL or
Resista or FiberTop B, C, E, or S, mechanically
fastened
Barrier Board: FiberTop C, E or S
Insulation
Minimum
Thickness
Maximum
Slope
Membranes
Class, Type
Any
½”
½”
UltraPly TPO
A, Fully
Adhered
Any
½”
½”
ReflexEON
A, Fully
Adhered
NC
Insulation (Optional): Firestone ISO 95+ GL or
FiberTop B, C, E or S
Any
¼”
ReflexEON
A, Fully
Adhered
C/NC
Insulation (Optional): Firestone ISO 95+ GL
Cover Board: Firestone ISOGARD HD or Resista
Any
1”
¼”
UltraPly TPO,
ReflexEON
A, Fully
Adhered
NC
Insulation (Optional): Firestone ISO 95+ GL
Any
¼”
UltraPly TPO
A, Fully
Adhered
NC
Insulation (Optional): Firestone ISO 95+ GL or
Resista
Coverboard or Insulation (Top): Firestone ISOGARD
HD or Resista
¼”
UltraPly TPO,
ReflexEON
A, Fully
Adhered
Any
½”
Construction:
Classification:
Recover
Retains Existing UL Classification Rating
Deck
Type
Insulation Assembly
Insulation
Minimum
Thickness
Maximum
Slope
Membranes
Class, Type
C/NC
Existing Class A, B or C BUR (smooth surface or cap
sheet)
Coverboard: Firestone ISOGARD HD
--½”
1/4”
UltraPly TPO,
ReflexEON
A/B/C,
Maintenance /
Repair
Maximum
Slope
Notes
Class, Type
3”
*DensDeck, ¼”
A, Fully
Adhered
Firestone Fully Adhered Systems with UltraPly TPO SA membrane
Membrane:
Adhesive:
Construction:
Classification:
UltraPly TPO SA (45 or 60 mil)
Self Adhered
New, Retrofit or Tear-off
Class A
Deck
Type
Insulation Assembly
NC
C*
Insulation (Optional): Firestone ISO 95+ GL
Barrier Board: DensDeck
Insulation
Minimum
Thickness
Any
¼”
C/NC
Insulation (Optional): Firestone ISO 95+ GL
Barrier Board: DensDeck
Any
¼”
3”
A, Fully
Adhered
C/NC
Insulation (Optional): Firestone ISO 95+ GL
Coverboard: Firestone ISOGard HD
Any
1”
½”
A, Fully
Adhered
NC
C*
Insulation (Optional): Firestone ISO 95+ GL
Coverboard: Firestone ISOGard HD
Any
½”
¾”
*DensDeck, ¼”
A, Fully
Adhered
8|P age
February 2014
Firestone Fully Adhered Systems with UltraPly TPO XR
Membrane:
Adhesive:
Construction:
Classification:
Deck
Type
C/NC
C/NC
UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil)
XR Bonding Adhesive @ 90 sq ft/gal
New, Retrofit or Tear-off
Class A
Insulation
Maximum
Insulation Assembly
Minimum
Slope
Thickness
Insulation (Optional): Firestone ISO 95+ GL
Any
1”
Coverboard: G-P Gypsum DensDeck or DensDeck
Prime
¼”
Any Classified LWIC
2”
1”
Notes
Class, Type
A, Fully
Adhered
A, Fully
Adhered
Firestone Fully Adhered Systems with UltraPly TPO XR
Construction:
Classification:
Deck
Type
C/NC
Recover
Retain Existing Class A, B, or C rating
Insulation
Insulation Assembly
Minimum
Thickness
Existing Class A, B or C BUR (smooth surface or cap
sheet)
---
Maximum
Slope
Notes
Class, Type
A/B/C,
Maintenance
/ Repair
1”
Firestone Fully Adhered (Hot Asphalt) Systems with UltraPly TPO XR
Membrane:
Adhesive:
Construction:
Classification:
Deck
Type
NC
C/NC
UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil)
Hot asphalt
New, Retrofit or Tear-off
Class A
Insulation
Maximum
Insulation Assembly
Minimum
Slope
Thickness
Notes
Class, Type
None
---
1”
A, Fully
Adhered
Insulation (Optional): Firestone ISO 95+ GL
Barrier Board: DensDeck
Any
¼”
1”
A, Fully
Adhered
Firestone Fully Adhered Systems with UltraPly TPO XR
Membrane:
Adhesive:
Construction:
Classification:
NC
C*
UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil)
Firestone ISO Spray S or Firestone XR Stick Adhesive
New, Retrofit or Tear-off
Class A
Insulation
Maximum
Insulation Assembly
Minimum
Slope
Thickness
Insulation (Optional): Firestone ISO 95+ GL,
Any
¼”
Resista, or ISOGARD HD
NC
C*
Structural Concrete or Lightweight Concrete decks
only
---
½”
Insulation (Optional): Firestone ISO 95+ GL
Barrier Board: DensDeck
Any
¼”
½”
Deck
Type
C/NC
Notes
Class, Type
*DensDeck, ¼”
A, Fully
Adhered
*DensDeck, ¼”
A, Fully
Adhered
A, Fully
Adhered
9|P age
February 2014
Firestone Mechanically Attached Systems
Membrane:
UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum
(80 mil)
Construction:
New, Retrofit or Tear-off
Classification:
Class A
Insulation
Deck
Maximum
Insulation Assembly
Minimum
Membrane
Class, Type
Type
Slope
Thickness
A,
Insulation (Optional): Firestone ISO 95+ GL or
Any
Mechanically
Resista
C/NC
4”
Ultraply TPO
¼”
Attached
Coverboard: DensDeck
A,
Any
NC
--4”
UltraPly TPO
Mechanically
¼”
Attached
A,
Insulation (Optional): Firestone ISO 95+ GL or
Any
Mechanically
Resista
NC
2”
UltraPly TPO
½”
Attached
Coverboard: Firestone FiberTop B, C, E, or S
C/NC
Two layers of “VersaShield Underlayment” or
“VersaShield FB-2S
Insulation (Optional): Firestone ISO 95+ GL or
Resista
Coverboard: Firestone ISOGARD HD or Resista
Any
NC
Insulation: Firestone ISO 95+ GL
Coverboard: Firestone ISOGARD HD or Resista
A,
Mechanically
Attached
A,
Mechanically
Attached
1”
UltraPly TPO
¾”
UltraPly TPO and
ReflexEON
Any
1”
½”
UltraPly TPO and
ReflexEON
Insulation: Firestone ISO 95+ GL
Any
½”
UltraPly TPO
C/NC
Two or more layers of Atlas "FR 50", mechanically
fastened
---
½”
UltraPly TPO
C/NC
Two layers “VersaShield Underlayment” or
“VersaShield FB-2S
Insulation: Firestone ISO 95+ GL
½”
UltraPly TPO
Insulation
Minimum
Thickness
Maximum
Slope
Membrane
Class, Type
--Any
½”
UltraPly TPO
A,
Mechanically
Attached
C/NC
NC
---
½”
--Any
A,
Mechanically
Attached
A,
Mechanically
Attached
A,
Mechanically
Attached
A,
Mechanically
Attached
Firestone Mechanically Attached Systems
Deck
Type
C/NC
Insulation Assembly
Two layers “VersaShield FB-1S, preliminary
attachment
Insulation (Optional): Firestone ISO 95+ GL
Firestone Mechanically Attached Recover Systems
Membrane:
UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil), ReflexEON (60 or 80 mil), ReflexEON Platinum
(80 mil)
Construction:
Recover
Classification:
Retain Existing Class A, B, or C rating
Deck Insulation Assembly
Insulation
Maximum
Notes
Type Example: Base Layer
Minimum
Slope
Class, Type
Top Layer
Thickness
C/NC
One layer of Atlas “FR 10” or “FR 11”, one layer
--1”
UltraPly TPO
A/B/C,
C/NC
One layer of “VersaShield Underlayment”
---
1”
UltraPly TPO
C/NC
Existing Class A, B or C BUR (smooth surface or cap
sheet)
Coverboard: Firestone ISOGARD HD
--½”
½”
UltraPly TPO and
ReflexEON
Maintenance
/ Repair
A/B/C,
Maintenance
/ Repair
A/B/C,
Maintenance
/ Repair
10 | P a g e
February 2014
Firestone Mechanically Attached Systems with UltraPly TPO XR
Membrane:
UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil)
Construction:
Recover
Classification:
Retain Existing Class A, B, or C rating
Deck Insulation Assembly
Insulation
Maximum
Type Example: Base Layer
Minimum
Slope
Top Layer
Thickness
Existing: To maintain A, B or C classification, insulated
C/NC
or un-insulated Type G3 mineral surfaced cap sheet,
--½”
or APP modified bitumen membrane roofing system.
Notes
Class, Type
A/B/C,
Maintenance
/ Repair
UL Internal Fire Ratings
In order to determine the resistance of a building to internal sources of fire, Underwriters Laboratories has conducted
extensive testing and classification of wall, floor/ceiling and roof/ceiling assemblies. UL classified assemblies are rated
according to the time in hours the assembly will contain a fire and still maintain structural integrity. Testing is
conducted in accordance with UL Standard 263 (ASTM E-119), which is recognized by all major building codes.
Roof/Ceiling Assemblies are listed in the UL Fire Resistance Directory - Vol. 1 under the prefix “P” and are
classified by hourly fire rating according to the type of protection used to contain a fire:
Assembly
P000 – P099
P200 – P299
P400 – P499
P500 – P599
P600 – P699
P700 – P799
P800 – P899
P900 – P999
Protection Used
Concealed grid suspended ceiling
Exposed grid suspended ceiling
Metal lathe (plaster) ceiling
Gypsum board ceiling
Miscellaneous fireproofing
Spray-Applied Resistive Material
Spray-Applied Resistive Material
Unprotected concrete or composite decks
It should be noted that the roof membrane forms only a small part of the total roof/ceiling assembly. In order for a
structure to qualify for a particular “P” Assembly or Roof Deck Construction, all materials used to construct the
assembly (including roof decking, ceiling materials, light fixtures, duct work and structural support members) must be
UL classified and installed as described in the appropriate UL Directories.
The insulations listed with each of the following “P” Assemblies are not, in most cases, the only UL accepted
insulations for that assembly. Consult the UL Fire Resistance Directory - Vol. 1 for “P” Assembly information and the
UL Roofing Materials and Systems Directory for Roof Deck Construction information, or call Firestone Technical
Services for additional accepted insulations.
UL has indicated on page 8 of the 2008 Fire Resistance Directory - Vol. 1 that "Class A, B or C roof coverings
consisting of hot mopped or cold applied bituminous materials or a roof covering material classified under 'Roofing
Membranes' (CHCI) may be applied directly to the concrete or wood surface of floor designs being used as roofs
without a reduction of fire resistance ratings." They further state on page 8 that "Roof insulation is to be carefully
controlled relative to manufacturer, type and thickness as specified. Less than the specified thickness could result in
higher temperatures on the roof covering while a greater thickness of insulation could cause earlier structural failure.
Classified polystyrene insulation, with a density of 5 pcf or less, may be placed on concrete floors or structural
concrete roofs without reducing the assembly rating. When …polyisocyanurate insulation is used over concrete in D
900 Series Designs, the unrestrained beam rating shall be increased by a minimum of ½ hour."
Roof Deck Constructions are listed in the UL Roofing Materials and Systems Directory and are rated according to
the interior flame spread of the assembly as compared to the flame spread of a typical built-up roof installed over a
metal deck (UL 1256). Roof Deck Constructions may also be classified according to wind uplift performance. The fire
rating of a UL Roof Deck Construction is similar to the Factory Mutual Class I internal fire (calorimeter) rating and they
are deemed equivalent by the Model Building Code Agencies.
11 | P a g e
February 2014
UL Roof Deck Constructions and “P” Assemblies
Deck Constructions (Tested in accordance to UL 1256)
Firestone UltraPly TPO 96/120 roofing systems are classified for use in the following Deck Construction:
1, 2, 9, 14, 120, 123, 158, 200, 219, 237, 260, 276, 289, 292, 325, 374, 411, 412, 413, 419, 421, 440, 441, 444,
457, and 458
Consult Roof Deck Constructions (TGKX) in the UL Roofing Materials and Systems Directory, your regional technical
coordinator or the Firestone Codes Department for an acceptable insulation for use in these constructions.
“P” Assemblies (Designs)
Firestone TPO 96/120 roofing systems are classified for use in the following hourly
P211, P214, P215, P216, P224, P225, P227, P229, P230, P231, P232, P235, P237,
P405, P406, P407, P410, P411, P505, P507, P508, P509, P510, P511, P513, P514,
P711, P712, P713, P717, P718, P719, P720, P722, P723, P724, P725, P726, P727,
P733, P734, P735, P736, P737, P738, P739, P801, P802, P803, P804, P805, P810,
P816, P817, P818, P819, P822, P823, P825, P826, P827, P902, P903, P904, P905,
P911, P912, P913, P914, P915, P916, P917, P918, P919, P920, P921, P922, P923,
P929, P930, P931.
roof / ceiling designs.
P241, P242, P246, P251,
P519, P701, P708, P709,
P728, P729, P730, P731,
P811, P812, P813, P814,
P906, P907, P908, P909,
P924, P925, P926, P927,
P259,
P710,
P732,
P815,
P910,
P928,
Consult Fire Resistance Ratings (BXUV) in the UL Fire Resistance Directory, your regional technical coordinator or the
Firestone Codes Department for an acceptable insulation, thickness and additional requirements.
NOTE: The accepted insulation must be used in a UL Class A, B or C rated roofing assembly. UL acceptable system
(e.g., adhering EPDM to Perlite or Fiberglass) listed for "P" design may not be approved for installation and warranty
by Firestone. Contact Firestone Specifications and/or your Firestone Regional Technical Coordinator concerning
acceptance. Please refer to pages 4 through 6 of this Approval Guide to determine the appropriate
insulation/membrane assembly.
Factory Mutual General Information
Factory Mutual Class 1 Approvals cover a wide range of testing of roofing products, including tests for fire resistance,
corrosion resistance, fuel contribution and hail damage, Factory Mutual Approvals are known best for the uplift resistance,
1-60, 1-90, etc. afforded by an FM Approved roofing assembly:
•
•
•
FM 1-60 assemblies have been tested to withstand 60 psf air pressure applied for a period of one minute as well as
one minute at the 30 and 45 psf levels.
FM 1-90 assemblies have been tested to withstand 90 psf air pressure applied for a period of one minute as well
as one minute at the 30, 45, 60 and 75 psf levels.
Higher uplift ratings are possible based on the deck type and its attachment, fastener density and row spacing
where applicable.
When Factory Mutual 1-60 or 1-90 uplift ratings are specified, additional insulation attachment and reduced perimeter and
corner batten (in-seam plate or batten for Reinforced Systems) spacing will/may be required. Consult the current edition of
Factory Mutual Loss Prevention Data Sheets 1-28 and 1-29 for instructions for determining the required corner and
perimeter dimensions and reduced spacing and increased fastener densities.
Ground Roughness Definitions
Ground Roughness B - Urban and suburban areas, well wooded areas or other terrain with numerous closely-spaced
obstructions the size of single family dwellings or larger.
Ground Roughness C - Open terrain with scattered obstructions of heights generally less than 30 ft. (9 m). This includes flat,
open country and grasslands.
Ground Roughness D - flat, unobstructed areas directly exposed to wind blowing over large bodies of water. This category
should be used for areas extending inland from the shore a distance of 1500 ft. (460m) or ten times the height of the
building or structure, whichever is greater.
(1)
Width of perimeter is 10% of the building width or 40% of the building height, whichever is smaller, but not less than
8.5 feet. Corner areas are square with side dimensions equal to the perimeter width, but the 10% lesser building
dimension limit is not applied in determining the corner dimension.
(2)
Wind speeds are taken from Factory Mutual Loss Prevention Data Sheet 1-28 and are based on a 100 year mean
recurrence interval.
(3)
Stone ballast shall be smooth stone, 1" to 2" nominal diameter, which meets the gradation requirements of standard
size No. 3 for coarse aggregate per ASTM D448 (85% larger than 1” diameter).
12 | P a g e
February 2014
Ballasted Systems
Factory Mutual tests and rates only fully adhered and mechanically attached systems; Factory Mutual does accept the use of
Ballasted Roof Systems on a job-to-job basis for FM insured clients. According to Mr. Edward J. Ward, Construction
Standards Manager for Factory Mutual Research, “... the Factory Mutual system windstorm loss experience has been
extremely favorable for single ply ballasted roof systems. When these roofs are installed in accordance with (Factory Mutual)
Loss Prevention Data Sheet 1-29, they are equally acceptable to Factory Mutual approved roofs.”
General Notations
PLEASE NOTE: Not all FM-rated assemblies that use Firestone roofing products are eligible for the Firestone
Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and
specifications regarding roofing system components and attachment for the warranty desired must be followed.
RoofNav® assemblies are summarized in the following tables; however, an assembly search should be conducted in order
to confirm the attachment rates and requirements set for in the approval number. In all occasions, should a discrepancy
occur between this guide and RoofNav, the published information located in the approval at www.roofnav.com should be
adhered and utilized.
Additionally, please be aware that the following assemblies typically are in reference to the field of the roof rating and
attachment. Please refer to FM Global Loss Prevention Data Sheet 1-28 and 1-29 to determine the requirements for
additional fastening requirements in the perimeter and corner.
In all cases, when the project is actually Factory Mutual insured, please consult the FM agent assigned to the review of the
project to ensure compliance.
The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone
Representative for approval of assembly for warranty purposes.
It is acceptable to use multiple layers of FM Approved insulation, mechanically secured through all layers, provided all
of the following are true:
•
All layers are the same insulation;
•
The total insulation thickness is not greater than the maximum FM Approved thickness of the insulation;
•
The mechanical fastening and wind uplift rating are per the FM Approval of the top layer; and,
•
The roof cover/insulation/fastener combination is FM Approved.
**Water Based Bonding Adhesive-P (WBBA-P) is the equivalent to Water Based Bonding Adhesive-S (WBBA-S).**
Assemblies in red font are recent additions to the Code Approval Guide.
Field/Corner/Perimeter Definitions
1.
2.
3.
4.
5.
6.
7.
8.
9.
Zone 1 except Zone 2 if θ> 7°.
Zone 2 except Zone 3 if θ≤ 7° and h > 60 ft (18 m).
Zone 2 except Zone 3 if θ< 7° and h ≤ 60 ft (18 m).
If a parapet height ≥ 3 ft (1 m) is provided around the
perimeter of the roof with θ≤ 7°, treat Zone 3 as Zone 2.
7° = 1-1/2”:12” (125 mm/m); 10° = 2”:12” (167 mm);
27° = 6”:12” (500 mm/m); 45° = 12”;12” (1 m/m).
Partially enclosed building multipliers for roofs are based
only on openings affecting the top story.
Value of “a”:
a)
For h ≤ 60 ft (18 m), “a” is the smaller of 0.1
times the building lesser plan dimension or 0.4
times h, and never less than 4% of the least
horizontal plan dimension, or 3 ft (0.9 m). Zone
3 is a square with dimensions “a”.
b)
For h > 60 ft (18 m), “a” is 0.1 times the building
lesser plan dimension, but not less than 3 ft (0.9
m). Zone 3 is an ell with dimensions “2a”.
Value of “h”:
a)
For slopes ≤ 10°, h = eave height
b)
For slopes > 10°, h = mean roof height
Value of “w” is based on the lesser plan dimension.
13 | P a g e
February 2014
Roof Design Negative Pressure Multipliers Zones 1, 2, 3 for Flat and Gabled Roofs
Apply multipliers to pressure values in Tables 3, 4, and 5, as appropriate.
Partially Enclosed Building⁶
Mean Roof Height, h
Roof Slope
Enclosed Building
Zone 1
Zone 2
Zone 3
Zone 1
Zone 2
Zone 3
h≤ 60 ft (18 m); and when
Θ ≤ 7°
1.0
1.68
2.53
1.31
1.99
2.85
h/w ≤ 1 for 60 < h < 90 ft (18
7° < θ ≤ 27°
0.92
1.59
2.36
1.23
1.91
2.67
< h < 27.4 m)
27° < θ ≤ 45°
1.0
1.17
1.17
1.31
1.48
1.48
When h/w > 1 for 60 ft < h <
Θ ≤ 10°
1.34
2.10
2.86
1.65
2.42
3.18
90 ft (18 < h < 27.4 m)
10° < θ ≤ 27°
0.92
1.59
2.36
1.23
1.91
2.67
See Note 6 below
27° < θ ≤ 45°
1.0
1.17
1.17
1.31
1.48
1.48
h ≥ 90 ft (27.4 m)
Θ ≤ 10°
1.0
1.57
2.14
1.23
1.80
2.37
See Note 6 below
10° < θ ≤ 27°
0.68
1.19
1.76
0.92
1.42
1.99
27° < θ ≤ 45°
0.75
0.87
0.87
0.98
1.11
1.11
Perimeter and Corner Treatment of Adjoining Buildings
14 | P a g e
February 2014
Prescriptive Enhancement Options: Perimeter and Corner
For all deck types, where roof covers are adhered to some combination of mechanically fastened insulation, cover board, or thermal
barriers, prescriptive enhancements may be used for securement of the perimeter and corner areas, as long as one of the conditions
below applies:
The building is in a non-hurricane prone region where the design wind speed does not exceed 90 mph and the roof height
does not exceed 75 ft (23 m). Note the roof height is limited to 30 ft (9.1 m) if the building is located in surface roughness
exposure D (see DS 1-28) and the building is partially enclosed.
•
Or
•
The recommended field of roof rating needed per DS 1-28 does not exceed Class 1-75 (3.6 kPa).
Or
•
The building is located in a non-hurricane prone area and the recommended field of the roof rating per Datasheet 1-28 does
not exceed Class 1-90.
For any of the three conditions above, increase the number of fasteners per board over the FM
Approved field of the roof spacing by the following:
•
•
•
50% minimum in the roof perimeter, but at least one fastener per 2 ft². (1 per 0.19 m²). It is not necessary to install
fasteners closer than one per 1 ft² (1 per 0.09 m²).
One fastener per 1 ft² (1 per 0.09 m2) in corner areas.
Round up to the next whole number of fasteners, if necessary.
Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System
Uplift
Deck
Type
Thermal Barrier
Vapor Barrier
System
Insulation Assembly
Membrane
Options
RoofNav
Assembly
Number
1-90
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
Concrete
(New or
recover)
DensDeck, ¼”
minimum, 8 AP or HD
fasteners and plates
per 4’x8’ board
DensDeck, ¼”
minimum, 8 AP or HD
fasteners and plates
per 4’x8’ board
DensDeck, ¼”
minimum, 8 HD or
Concrete Drive
fasteners and plates
per 4’x8’ board
Primed thermal
barrier with VForce SB Primer
ISO 95+ GL, 1.5” minimum, 4’x4’
boards, adhered with I.S.O. Stick at 12”
on center
UltraPly TPO,
ReflexEON
294762-0-0
Primed thermal
barrier with VForce SB Primer
2 Layers - ISO 95+ GL, 1.5” minimum,
4’x4’ boards, adhered with I.S.O. Stick
at 12” on center
UltraPly TPO,
ReflexEON
294764-0-0
Primed thermal
barrier with VForce SB Primer
UltraPly TPO,
ReflexEON
294593-0-0
1-90
Concrete
(New or
recover)
DensDeck, ¼”
minimum, 8 HD or
Concrete Drive
fasteners and plates
per 4’x8’ board
Primed thermal
barrier with VForce SB Primer
ISO 95+ GL, 1.5” minimum, 4’x4’
boards, adhered with I.S.O. Stick at 12”
on center
FiberTop C, E or S, ½”; or ISOGard HD,
½”; or
DensDeck, 1/4”; or
APA rated OSB, 7/16”,
4’x4’ boards, adhered with I.S.O. Stick
at 12” on center
2 Layers - ISO 95+ GL, 1.5” minimum,
4’x4’ boards, adhered with I.S.O. Stick
at 12” on center
UltraPly TPO,
ReflexEON
294633-0-0
1-525
Concrete
(New or
recover)
None
Primed substrate
with V-Force SB
Primer
ISO 95+ GL, 1.5” minimum, 4’x4’
boards, adhered with I.S.O. Stick at 12”
on center
UltraPly TPO,
ReflexEON
294948-0-0
1-525
Concrete
(New or
recover)
Concrete
(New or
recover)
None
Primed substrate
with V-Force SB
Primer
Primed substrate
with V-Force SB
Primer
2 Layers - ISO 95+ GL, 1.5” minimum,
4’x4’ boards, adhered with I.S.O. Stick
at 12” on center
DensDeck, DensDeck Prime, or
SECUROCK AT ¼” min.
ISO 95+ GL, 1.5” minimum, 4’x4’
boards, adhered with I.S.O. Twin Pack
at 12” on center
UltraPly TPO,
ReflexEON
294949-0-0
UltraPly TPO,
ReflexEON
295522-0-0
1-90
1-90
1-795
None
15 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – Standard UltraPly TPO
New Construction, Concrete Deck, Adhesively Attached Insulation, Without Coverboard
Uplift
Deck Type
Insulation
Insulation
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-555
Concrete
12” o.c. beads of
ISO Spray S
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly Bonding
Adhesive
A
304517-0-0
1-330
Concrete
Tapered ISO 95+
GL, .5” min.
ISO 95+ GL, 1”-4”
4’x4’ boards
ISO 95+ GL, 1.5”12”, 4’x4’ boards
12” o.c. beads of
Twin Pack Adhesive
223517-0-0
Concrete
ISO 95+ GL, 1.5”-4”,
4’x4’ boards
ISO Spray S, full
application
A
80684-0-0
1-360
Concrete
ISO 95+ GL, 1.5”-4”,
4’x4’ boards
Asphalt Attached,
full application
A
245813-0-0
1-480
Concrete
ISO 95+ GL, 1.5”12”, 4’x4’ boards
8” o.c. beads of
Twin Pack Adhesive
A
223518-0-0
1-540
Concrete
ISO 95+ GL, 1.5”12”, 4’x4’ boards
A
228481-0-0
1-570
Concrete
ISO 95+ GL, 1.5”12”, 4’x4’ boards
12” o.c. beads of
I.S.O. Stick
Adhesive
4” o.c. beads of
Twin Pack Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
UltraPly or Single Ply
LVOC Bonding
Adhesive
A
1-360
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
A
223523-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard
Uplift
Deck Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-120
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
12” o.c.
beads of
I.S.O. Stick
Adhesive
FiberTop, ½”
minimum, 4’x4’
boards
12” o.c.
beads of
I.S.O. Stick
Adhesive
UltraPly or
ReflexEON
membrane
A
228477-0-0
1-120
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
12” o.c.
beads of
I.S.O. Stick
Adhesive
12” o.c.
beads of
I.S.O. Stick
Adhesive
UltraPly or
ReflexEON
membrane
A
228479-0-0
1-120
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
12” o.c.
beads of
I.S.O. Fix
Adhesive
DensDeck,
DensDeck Prime,
or SECUROCK,
¼” minimum,
4’x4’ boards
ISOGard HD, ½”,
4’x4’ boards
12” o.c.
beads of
I.S.O. Fix
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
Water
Based
Bonding
Adhesive-S
A
233376-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Concrete Deck, Adhesively Attached Insulation, With Coverboard
Uplift
Deck Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-255
Concrete
ISO 95+
GL, 1.5” 12”, 4’x4’
boards
12” o.c.
beads of
Twin Pack
Adhesive
DensDeck Prime
or SECUROCK,
¼” min., 4’x4’
boards
12” o.c.
beads of
Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
A
223524-0-0
16 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
Uplift
Deck Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-495
Concrete
Tapered
ISO 95+
GL, .5”
min, ISO
95+ GL
1.5”-8”
DensDeck Prime,
¼” min., 4’x4’
boards
12” o.c.
beads of
Twin Pack,
Fix II, Spray
S, Stick
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly
Bonding
Adhesive
A
346005-0-0
1-255
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
12” o.c.
beads of
Twin Pack,
Fix II,
Spray S,
Stick
Adhesive
12” o.c.
beads of
Twin Pack
Adhesive
DensDeck Prime
or SECUROCK,
¼” min., 4’x4’
boards
12” o.c.
beads of
Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
A
223524-0-0
1-270
Concrete
A
233376-0-0
A
233380-0-0
1-270
Concrete
12” o.c.
beads of
Twin Pack
Adhesive
12” o.c.
beads of
I.S.O. Stick
Adhesive
ISO Spray
S, full
application
UltraPly or
ReflexEON
membrane
Concrete
12” o.c.
beads of
Twin Pack
Adhesive
12” o.c.
beads of
I.S.O. Stick
Adhesive
ISO Spray
S, full
application
ISOGard HD, ½”,
4’x4’ boards
1-270
ISO 95+
GL, 1.5” 12”, 4’x4’
boards
ISO 95+
GL, 1.5”12”, 4’x4’
boards
ISO 95+
GL, 1.5”-4”
4’x4’
boards
A
80622-0-0
1-270
Concrete
ISO 95+
GL, 1.5”4”, 4’x4’
boards
Asphalt
Attached,
full
application
FiberTop, 1/2”
minimum, 4’x4’
boards
Asphalt
Attached,
full
application
UltraPly or
ReflexEON
membrane
A
245808-0-0
1-375
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
8” o.c.
beads of
Twin Pack
Adhesive
DensDeck Prime
or SECUROCK,
¼” min., 4’x4’
boards
8” o.c.
beads of
Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
A
223525-0-0
1-390
Concrete
Tapered
ISO 95+
GL, 1.5”
minimum
8” o.c.
beads of
Twin Pack
Adhesive
DensDeck or
SECUROCK, ¼”
min., 4’x4’
boards
8” o.c.
beads of
Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
A
113754-0-0
1-390
Concrete
ISO Spray
S, full
application
UltraPly
membrane
A
135967-0-0
Concrete
A
245811-0-0
Concrete
Asphalt
Attached,
full
application
12” o.c.
beads of
I.S.O. Stick
Adhesive
UltraPly or
ReflexEON
membrane
1-495
Asphalt
Attached,
full
application
12” o.c.
beads of
I.S.O. Stick
Adhesive
DensDeck or
SECUROCK, ¼”
minimum, 4’x4’
boards
DensDeck or
SECUROCK, ¼”
minimum, 4’x4’
boards
APA Rated OSB,
7/16” minimum,
4’x4’ boards
ISO Spray
S, full
application
1-390
ISO 95+
GL, 1.5”4”, 4’x4’
boards
ISO 95+
GL, 1.5”4”, 4’x4’
boards
ISO 95+
GL, 1.5”12”, 4’x4’
boards
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
Water
Based
Bonding
Adhesive
Water
Based
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly
Bonding
Adhesive
A
228464-0-0
1-600
Concrete
ISO 95+
GL, 1.5”12”, 4’x4’
boards
12” o.c.
beads of
I.S.O. Stick
Adhesive
A
233379-0-0
ISOGard HD, ½”,
4’x4’ boards
FiberTop, 1/2”
minimum, 4’x4’
boards
ISOGard HD, ½”,
4’x4’ boards
12” o.c.
beads of
I.S.O. Stick
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
Single Ply
Bonding
Adhesive
UltraPly or
Single Ply
LVOC
Bonding
Adhesive
UltraPly or
Bonding
Adhesive
17 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With
Coverboard
Uplift
Deck Type
(Vapor
Retarder)
Insulation and
Attachment
Coverboard and
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Cementitious
Wood Fiber Tectum Plank
ISO 95+ GL, 1.5”4”, 4’x4’ boards,
12” o.c. beads of
I.S.O. Fix Adhesive
UltraPly or
ReflexEON
membrane
112012-0-0
Concrete, SA
Primer (MB
Base SA)
A
202799-0-0
1-465
Concrete, (SBS
Poly/Glass
Torch Base or
SBS Smooth)
ISO 95+ GL, 1.5”12”, 4’x4’ boards,
12” o.c. beads of
Twin Pack Adhesive
Tapered ISO 95+
GL, 1.5” minimum
(Opt. Layer), 12”
o.c. beads of Twin
Pack Adhesive
UltraPly, Water
Based Bonding
Adhesive-S or
Single Ply LVOC
Bonding Adhesive
UltraPly or Single
Ply LVOC Bonding
Adhesive
A
1-240
DensDeck or
SECUROCK, ¼”
minimum, 4’x4’ boards,
12” o.c. beads of I.S.O.
Fix Adhesive
None
DensDeck, DensDeck
Prime, ¼” minimum,
4’x4’ boards, 12” o.c.
beads of Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly Bonding
Adhesive
A
233200-0-0
UltraPly or
ReflexEON
membrane
Firestone Fully Adhered Uplift Ratings
New Construction, Steel, Vapor Barrier, Adhesively Attached Insulation
Uplift
Deck
Type
Vapor
Barrier
Insulation and
Attachment
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Steel,
22-16
gauge,
Grade C
MB
Base SA
ISO 95+ GL,
1.5”-12”,
4’x4’ boards
And
DensDeck
Prime or
SECUROCK,
5/8” thick
12” o.c.
beads of
Twin Pack
Adhesive
DensDeck
Prime or
SECUROCK
¼”
minimum
12” o.c.
beads of
Twin Pack
Adhesive
UltraPly
membrane
UltraPly
Bonding
Adhesive
A
200893-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard
Uplift
Deck Type
Insulation
Insulation Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Steel, 22-16
gauge, Grade
C
Concrete
ISO 95+ GL,
1.5”-12”
12 AP or HD fasteners
per 4’x8’ board
UltraPly or
ReflexEON
membrane
UltraPly, Water Based
Bonding or Single Ply
LVOC Bonding Adhesive
A
2113-0-0
Steel, 22-16
gauge, Grade
C
Steel, 22-18
gauge, Grade
C
ISO 95+ GL,
2”-12”
8 AP or HD fasteners
per 4’x8’ board
ISO 95+ GL,
1.5”-12”
18 AP or HD fasteners
per 4’x8’ board
Steel, 22-18
gauge, Grade
C
Concrete
ISO 95+ GL,
1.5”-4”
24 AP fasteners per
4’x8’ board
ISO 95+ GL,
2”-4”
20 Concrete Drive or
HD fasteners per 4’x8’
board
1-90
1-120
1-180
1-120
HD fasteners only
2106-0-0
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or Single Ply
LVOC Bonding Adhesive
A
191607-0-0
UltraPly or Single Ply
LVOC Bonding Adhesive
A
127787-0-0
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly Bonding
Adhesive
A
233194-0-0
Water Based Bonding
Adhesive (WBBA)
A
296301-0-0
18 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete, Mechanically Attached Insulation without Coverboard
Uplift
Deck Type
Insulation
Insulation Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-150
Steel, 22-18
gauge, Grade
C
Steel, 22-18
gauge, Grade
C
ISO 95+ GL,
2”-4”
20 AP fasteners per
4’x8’ board
UltraPly
membrane
UltraPly Bonding
Adhesive
A
233195-0-0
ISO 95+ GL,
2”-12”
32 AP or HD fasteners
per 4’x8’ board
UltraPly or
ReflexEON
membrane
UltraPly or Single Ply
LVOC Bonding Adhesive
A
228346-0-0
1-225
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-75
Steel,
22-16
gauge,
Grade C
ISO 95+
GL, 1”-12”
Loose Laid
FiberTop
(C,E,S),
1/2”
minimum
12 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
A
2063-0-0
1-75
Concrete
ISO 95+
GL, 1.5”12”
Loose Laid
FiberTop
(C,E,S),
1/2”
minimum
12 HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
A
2061-0-0
1-90
Steel,
22-16
gauge,
Grade C
ISO 95+
GL, 1.5”12”
Loose Laid
DensDeck or
SECUROCK
1/4”
minimum
15 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
A
112795-0-0
1-90
Steel,
22-16
gauge,
Grade C
Loose Laid
DensDeck or
SECUROCK
1/4”
minimum
12 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
A
209896-0-0
1-90
Concrete
ISO 95+
GL, 1.5”-8”
Optional:
Iso 95+ GL
(tapered),
.5”-4”
ISO 95+
GL, 1”-12”
Loose Laid
DensDeck or
SECUROCK
1/4”
minimum
18 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
A
2064-0-0
1-150
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
ISO 95+
GL, 1.5”12”
Loose Laid
A
200412-0-0
Loose Laid
25 AP or HD
fasteners
per 4’x8’
boards
32 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
ISO 95+
GL, 1.5”12”
DensDeck or
SECUROCK
1/4”
minimum
DensDeck or
SECUROCK
1/4”
minimum
A
200414-0-0
1-90
Steel,
20-18
gauge,
Grade C
ISO 95+
GL, 1.5”6.5”
Loose Laid
APA rated
OSB, 7/16”
minimum
12 HailGard
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
A
136153-0-0
1-105
Steel,
22-18
gauge,
Grade C
ISO 95+
GL, 1.5”6.5”
Loose Laid
APA rated
OSB, 7/16”
minimum
20 HailGard
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly or
Single Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
A
136151-0-0
1-210
UltraPly or
ReflexEON
membrane
19 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
1-150
Steel,
22-18
gauge,
Grade C
ISO 95+
GL, 1.5”12”
Loose Laid
1-300
Steel,
22-18
gauge,
Grade C
ISO 95+
GL, 1.5”12”
1-90
Steel,
22-18
gauge,
Grade C
HailGard,
2”-4”
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
APA rated
OSB, 7/16”
minimum
16 AP or HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
A
77830-0-0
Loose Laid
APA rated
OSB, 7/16”
minimum
32 HD
fasteners
per 4’x8’
boards
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
UltraPly or
Single Ply LVOC
Bonding
Adhesive
A
171664-0-0
13 HailGard
fasteners
per 4’x8’
boards
None
None
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
A
136363-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete, Insulation with Mechanically Attached Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-105
Steel,
22-18
gauge,
Grade C
HailGard,
2”-4”
20 HailGard
fasteners
per 4’x8’
boards
None
None
UltraPly or
ReflexEON
membrane
UltraPly, Water
Based or Single
Ply LVOC
Bonding
Adhesive
A
136362-0-0
1-165
Steel,
22-18
gauge,
Grade C
HailGard,
2”-4”
32 HD
fasteners
per 4’x8’
boards
None
None
UltraPly or
ReflexEON
membrane
UltraPly Single
Ply LVOC
Bonding
Adhesive
A
328832-0-0
1-300
Steel,
22-18
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
HailGard,
2”-4”
32 HD
fasteners
per 4’x8’
boards
Loose Laid
None
None
UltraPly or
ReflexEON
membrane
A
171662-0-0
ISOGard
HD, ½”
thickness
12 AP or HD
fasteners
per 4’x8’
boards
12” o.c.
beads of
Twin Pack
Adhesive
12” o.c.
beads of
Twin Pack
Adhesive
12” o.c.
beads of
Twin Pack
Adhesive
UltraPly or
ReflexEON
membrane
UltraPly Single
Ply LVOC
Bonding
Adhesive
UltraPly Single
Ply LVOC
Bonding
Adhesive
UltraPly Single
Ply LVOC
Bonding
Adhesive
UltraPly Single
Ply LVOC
Bonding
Adhesive
UltraPly Single
Ply LVOC
Bonding
Adhesive
A
233370-0-0
A
233373-0-0
A
233196-0-0
A
230423-0-0
1-90
1-90
1-90
1-90
ISO 95+ GL,
1.5”-12”
ISO 95+ GL,
1.5”-12”
ISO 95+ GL,
1.5”-4”
ISO 95+ GL,
1.5”-4”
16 AP or HD
fasteners
per 4’x8’
board
16 AP or HD
fasteners
per 4’x8’
board
16 AP or HD
fasteners
per 4’x8’
board
ISOGard
HD, ½”
thickness
DensDeck or
DensDeck
Prime, ¼”
minimum
ISO 95+ GL
(tapered),
0.5”-4”
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
UltraPly or
ReflexEON
membrane
20 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Steel Deck, Mechanically Attached Insulation, Without Coverboard
Uplift
Deck
Type
Insulation
Insulation Attachment
Membrane
Notes
Exterior
Fire
Rating
RoofNav
Number
1-90
Steel,
22-16
gauge,
Grade C
Firestone ISO
95+ GL, 1.5”-8”
thickness
12 AP or HD fasteners
and plates per 4’x8’
board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Optional: 6 mil
polyethylene vapor
retarder direct to
deck
A
287981-0-0
1-120
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
Firestone ISO
95+ GL, 2”-8”
thickness
18 AP or HD fasteners
and plates per 4’x8’
board
287915-0-0
20 AP or HD fasteners
and plates per 4’x8’
board
A
287937-0-0
Firestone ISO
95+ GL, 1.5”12” thickness
24 AP or HD fasteners
and plates per 4’x8’
board
A
287934-0-0
Firestone ISO
95+ GL, 2”-8”
thickness
32 AP or HD fasteners
and plates per 4’x8’
board
Optional: 6 mil
polyethylene vapor
retarder direct to
deck
Optional: 6 mil
polyethylene vapor
retarder direct to
deck
Optional: 6 mil
polyethylene vapor
retarder direct to
deck
Optional: 6 mil
polyethylene vapor
retarder direct to
deck
A
Firestone ISO
95+ GL, 2”-8”
thickness
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
287929-0-0
1-165
1-165
1-225
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Concrete Deck, Mechanically Attached Insulation, Without Coverboard
Uplift
Deck
Type
Insulation
Insulation Attachment
Membrane
Notes
Exterior
Fire
Rating
RoofNav
Number
1-90
Concrete
Firestone ISO
95+ GL, 1.5”4” thickness
12 HD or Concrete
Drive fasteners and
plates per 4’x8’ board
Optional: Firestone
ISO 95+ GL, 1.5”4” thickness
A
287979-0-0
1-120
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
18 HD or Concrete
Drive fasteners and
plates per 4’x8’ board
Optional: Firestone
ISO 95+ GL, 1.5”4” thickness
A
287910-0-0
1-165
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
20 HD or Concrete
Drive fasteners and
plates per 4’x8’ board
Optional: Firestone
ISO 95+ GL, 1.5”4” thickness
A
287935-0-0
1-165
Concrete
Firestone ISO
95+ GL, 1.5”4” thickness
24 HD or Concrete
Drive fasteners and
plates per 4’x8’ board
Optional: Firestone
ISO 95+ GL, 1.5”4” thickness
A
287931-0-0
1-225
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
32 HD or Concrete
Drive fasteners and
plates per 4’x8’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
Optional: Firestone
ISO 95+ GL, 1.5”4” thickness
A
287925-0-0
21 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation
Uplift
Deck
Type
Insulation
Insulation
Attachment
Insulation
(Top)
Insulation
(Top)
Attachment
Membrane
Notes
Exterior
Fire
Rating
RoofNav
Number
1-60
Steel,
22-16
gauge,
Grade
C
12 AP or
HD
fasteners
and plates
per 4’x8’
board
Firestone ISO
95+ GL, 1.5”4” thickness,
or Optional:
ISO 95+ GL
(tapered), .5”4” thickness
12” o.c.
beads of
Twin Pack
Adhesive,
4’x4’ boards
Firestone
UltraPly TPO SA
(Single-Ply
QuickPrime
Primer to primed
roof insulation)
Optional: 6
mil
polyethylene
A
288098-0-0
1-75
Steel,
22-16
gauge,
Grade
C
8 AP or HD
fasteners
and plates
per 4’x8’
board
Firestone ISO
95+ GL, 1.5”
Thickness
or Optional:
ISO 95+ GL
(tapered), .5”4” thickness
12” o.c.
beads of
Twin Pack
Adhesive,
4’x4’ boards
Firestone
UltraPly TPO SA
(Single-Ply
QuickPrime
Primer to primed
roof insulation)
Optional: 6
mil
polyethylene
A
288104-0-0
1-90
Steel,
22-16
gauge,
Grade
C
Firestone
ISO 95+
GL, 2.0”4”
Thickness
Optional:
ISO 95+
GL 1.5”-4”
thickness
Firestone
ISO 95+
GL, 2.0”4”
Thickness
Optional:
ISO 95+
GL 1.5”-4”
thickness
Firestone
ISO 95+
GL, 1.5”4”
thickness
16 AP or
HD
fasteners
and plates
per 4’x8’
board
12” o.c.
beads of
I.S.O. Spray
S Adhesive,
4’x4’ boards
Firestone
UltraPly TPO SA
(Single-Ply
QuickPrime
Primer to primed
roof insulation)
A
303978-0-0
1-150
Steel,
22-18
gauge,
Grade
C
Firestone ISO
95+ GL, 1.5”
Thickness
or Optional:
ISO 95+ GL
(tapered), .5”4” thickness
Firestone ISO
95+ GL, 1.5”
thickness
12” o.c.
beads of
Twin Pack
Adhesive,
4’x4’ boards
Firestone
UltraPly TPO SA
(Single-Ply
QuickPrime
Primer to primed
roof insulation)
A
287963-0-0
Firestone
ISO 95+
GL, 2.0”4”
Thickness
Optional:
ISO 95+
GL 1.5”-4”
thickness
20 AP or
HD
fasteners
and plates
per 4’x8’
board
Optional: 6
mil
polyethylene
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached
Insulation
Uplift
Deck
Type
Insulation
Insulation
Attachment
Insulation
Insulation (Top)
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-60
Concrete
12 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone ISO
95+ GL, 1.5”
Thickness
or Optional:
ISO 95+ GL
(tapered), .5”
-4” thickness
12” o.c. beads
of Twin Pack
Adhesive, 4’x4’
boards
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
288090-0-0
1-75
Concrete
Firestone ISO
95+ GL, 1.5”4”
Thickness
Optional:
ISO 95+ GL
1.5”-4”
thickness
Firestone ISO
95+ GL, 2”-4”
Thickness
Optional:
ISO 95+ GL
1.5”-4”
thickness
8 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone ISO
95+ GL, 1.5”
Thickness
or Optional:
ISO 95+ GL
(tapered), .5”
-4” thickness
12” o.c. beads
of Twin Pack
Adhesive, 4’x4’
boards
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
288099-0-0
22 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Uplift
Deck
Type
Insulation
Insulation
Attachment
Insulation
Insulation (Top)
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-90
Concrete
Firestone ISO
95+ GL, 1.5”4”
Thickness
16 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
12” o.c. beads
of I.S.O. Spray
S Adhesive,
4’x4’ boards
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
303942-0-0
1-150
Concrete
Firestone ISO
95+ GL, 1.5”4”
Thickness
Optional:
ISO 95+ GL
1.5”-4”
thickness
20 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone ISO
95+ GL, 1.5”
Thickness
or Optional:
ISO 95+ GL
(tapered),
1.5”-4”
thickness
Firestone ISO
95+ GL, 1.5”4
thickness
12” o.c. beads
of Twin Pack
Adhesive, 4’x4’
boards
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
287939-0-0
Exterior
Fire
Rating
RoofNav
Number
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Steel Deck, Insulation with Mechanically Attached Coverboard
Uplift
Deck
Type
Insulation
And Attachment
Coverboard
Coverboard
Attachment
Membrane
1-75
Steel,
22-16
gauge,
Grade C
Firestone ISO 95+
GL, 1.5”-4”
thickness; Loose
Laid
15 AP or HD
fasteners and
plates per 4’x8’
board
1-90
Steel,
22-16
gauge,
Grade C
Firestone ISO 95+
GL, 1.5”
thickness, Loose
Laid
DensDeck,
1/4”
Minimum.
SECUROCK,
½” Minimum
FiberTop C, E
or S, 1”
thickness
1-90
Steel,
22-16
gauge,
Grade C
Firestone ISO 95+
GL, 1.5”-4”
thickness, Loose
Laid
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone
ISOGard HD,
½”-1”
thickness
16 AP or HD
fasteners and
plates per 4’x8’
board
12 AP or HD
fasteners and
plates per 4’x8’
board
Notes
Optional: 6
mil
polyethylene
A
287989-0-0
Optional: 6
mil
polyethylene
A
287998-0-0
Optional: 6
mil
polyethylene
A
287976-0-0
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
New Construction, Concrete Deck, Insulation with Mechanically Attached Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-75
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
Loose Laid
Loose Laid
A
287996-0-0
1-90
Concrete
Firestone ISO
95+ GL, 1.5”-4”
Thickness
Optional:
ISO 95+ GL,
1.5”
thickness
Firestone ISO
95+ GL, 1.5”-4”
thickness
Firestone UltraPly TPO
SA
(Single-Ply
QuickPrime Primer to
primed roof insulation)
Firestone UltraPly TPO
SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
287986-0-0
Concrete
15 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
16 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
A
1-90
DensDeck,
1/4”
Minimum.
SECUROCK,
½” Minimum
FiberTop
C, E or S,
1” thickness
Firestone
ISOGard
HD, ½”-1”
thickness
12 HD or Concrete
Drive fasteners and
plates per 4’x8’
board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
287973-0-0
Loose Laid
23 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Re-Roof/New Construction, Concrete and Gypsum, Adhesive Attachment Insulation/Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-105
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
FiberTop C,
E, and S, .5”1” thickness.
12” o.c. with
Twin Pack
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288014-0-0
1-135
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
None
None
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288018-0-0
1-330
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
DensDeck,
DensDeck
Prime, or
SECUROCK
¼” minimum
12” o.c. with
Twin Pack
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288040-0-0
1-405
Concrete
Firestone ISO
95+ GL, 1”-4”
thickness
ISOGARD HD
½”-1”
thickness
12” o.c. with
I.S.O. Spray S
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
304387-0-0
1-420
Concrete
Firestone ISO
95+ GL, 1”-4”
thickness
ISOGARD HD
½”-1”
thickness
12” o.c. with
I.S.O. Spray S
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
304083-0-0
1-555
Concrete
Firestone ISO
95+ GL, 1”-4”
thickness
None
None
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
304071-0-0
1-585
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
None
None
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288024-0-0
1-90
Gypsum
Firestone ISO
95+ GL, 1.5”-4”
thickness
None
None
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288022-0-0
1-90
Gypsum
Firestone ISO
95+ GL, 1.5”-4”
thickness
Firestone
ISOGard HD,
½”-1”
thickness
12” o.c. with
Twin Pack
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288032-0-0
1-90
Gypsum
Firestone ISO
95+ GL, 1.5”-4”
thickness
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with I.S.O.
Spray S
Adhesive
per 4’x4’
board
12” o.c.
with I.S.O.
Spray S
Adhesive
per 4’x4’
board
12” o.c.
with I.S.O.
Spray S
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
DensDeck,
DensDeck
Prime, or
SECUROCK
¼” minimum
12” o.c. with
Twin Pack
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288044-0-0
24 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Uplift
1-90
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
Gypsum
Firestone ISO
95+ GL, 1.5”-4”
thickness
12” o.c.
with Twin
Pack
Adhesive
per 4’x4’
board
FiberTop C,
E, and S, .5”1” thickness.
12” o.c. with
Twin Pack
Adhesive per
4’x4’ board
Firestone UltraPly TPO
SA (Single-Ply
QuickPrime Primer to
primed roof insulation)
A
288016-0-0
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Recover, Concrete Deck, Mechanically Attached Insulation, Without Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Membrane
Notes
Exterior
Fire
Rating
RoofNav
Number
1-75
Concrete
Firestone ISO
95+ GL, 1”-4”
thickness
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
None
A
287984-0-0
1-90
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
Optional: Firestone
ISO 95+ GL, 1.5”-4”
thickness, direct to
substrate
A
287980-0-0
1-120
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
16 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
12 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
18 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
Optional: Firestone
ISO 95+ GL, 1.5”-4”
thickness, direct to
substrate
A
287912-0-0
1-165
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
20 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
Optional: Firestone
ISO 95+ GL, 1.5”-4”
thickness, direct to
substrate
A
287936-0-0
1-165
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
24 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
Optional: Firestone
ISO 95+ GL, 1.5”-4”
thickness, direct to
substrate
A
287933-0-0
1-225
Concrete
Firestone ISO
95+ GL, 2”-4”
thickness
32 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone UltraPly TPO SA
(Single-Ply QuickPrime
Primer to primed roof
insulation)
Optional: Firestone
ISO 95+ GL, 1.5”-4”
thickness, direct to
substrate
A
287926-0-0
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Recover, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation
Uplift
Deck
Type
Insulation
Insulation
Attachment
Insulation
(Top)
Insulation (Top)
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-150
Concrete
Firestone ISO
95+ GL, 1.5”-8”
thickness
20 HD or
Concrete
Drive
fasteners and
plates per
4’x8’ board
Firestone
ISO 95+ GL,
1.5”-4”
thickness
12” o.c. beads of
Twin Pack
Adhesive, 4’x4’
boards
Firestone UltraPly
TPO SA
(Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
287955-0-0
25 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Recover, Concrete Deck, Mechanically Attached Insulation/Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-75
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
Loose Laid
15 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
287987-0-0
1-90
Concrete
Firestone ISO
95+ GL, 1.5”-8”
thickness
Loose Laid
DensDeck,
1/4”
Minimum.
SECUROCK,
½”
minimum
FiberTop C,
E or S, 1”
thickness
287997-0-0
Concrete
Firestone ISO
95+ GL, 1.5”-4”
thickness
Loose Laid
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
1-90
16 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
12 HD or
Concrete Drive
fasteners and
plates per 4’x8’
board
A
287974-0-0
Firestone
ISOGard
HD, ½”-1”
thickness
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Recover, Steel Deck, Mechanically Attached Insulation/Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
1-75
Steel,
22-18
gauge,
Grade C
Firestone ISO
95+ GL, .5”-1”
minimum
16 AP or HD
fasteners and
plates per
4’x8’ board
None
None
A
287982-0-0
1-75
Steel,
22-18
gauge,
Grade C
None
None
15 AP or HD
fasteners and
plates per 4’x8’
board
A
287990-0-0
1-90
Steel,
22-18
gauge,
Grade C
None
None
DensDeck,
1/4”
Minimum.
SECUROCK,
½”
minimum
FiberTop C,
E or S, .5”1” thickness
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
287999-0-0
1-90
Steel,
22-18
gauge,
Grade C
None
None
A
287977-0-0
Firestone
ISOGard
HD, ½”-1”
thickness
16 AP or HD
fasteners and
plates per 4’x8’
board
12 AP or HD
fasteners and
plates per 4’x8’
board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Recover, Various Deck Types, Adhesive Attachment Insulation/Coverboard
Uplift
1-90
Deck Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
Gypsum
None
None
Firestone
ISOGard
HD, ½”
thickness
12” o.c. with Twin
Pack Adhesive per
4’x4’ board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
288036-0-0
Cementitious
Woodfiber
288037-0-0
26 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane
Uplift
1-90
Deck Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Exterior
Fire
Rating
RoofNav
Number
Gypsum
None
None
DensDeck or
SECUROCK,
1/4”
Minimum.
12” o.c. with Twin
Pack Adhesive per
4’x4’ board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
288053-0-0
Firestone
ISOGard
HD, ½”
thickness
12” o.c. with Twin
Pack Adhesive per
4’x4’ board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
DensDeck or
SECUROCK,
1/4”
Minimum.
12” o.c. with Twin
Pack Adhesive per
4’x4’ board
Firestone UltraPly
TPO SA (Single-Ply
QuickPrime Primer
to primed roof
insulation)
A
Cementitious
Woodfiber
1-315
1-315
Steel, 22-18
gauge,
Grade C
Concrete
None
Steel, 22-18
gauge,
Grade C
Concrete
None
None
None
288054-0-0
288034-0-0
288033-0-0
288052-0-0
288051-0-0
Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane
New Construction, Steel or Concrete Deck, Insulation without Coverboard, UltraPly XR membrane
Uplift
Deck
Type
Insulation
Insulation Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Steel,
22-16
gauge,
Grade C
Concrete
ISO 95+ GL,
1.5”-4”
thickness
16 AP or HD fasteners
per 4’x8’ board
UltraPly XR
100, 115, 135
membrane
ISO Spray S or XR
Stick, 12” on center
A
289254-0-0
ISO 95+ GL,
1.5”-4”
thickness
ISO 95+ GL,
2”-4”
thickness
16 HD or Concrete
fasteners per 4’x8’
board
20 AP or HD fasteners
per 4’x8’ board
UltraPly XR
100, 115, 135
membrane
UltraPly XR
100, 115, 135
membrane
ISO Spray S or XR
Stick, 12” on center
A
289250-0-0
ISO Spray S or XR
Stick, 6” on center
A
292119-0-0
ISO 95+ GL,
2”-4”
thickness
ISO 95+ GL,
2”-4”
thickness
ISO 95+ GL,
2”-4”
thickness
20 HD or Concrete
fasteners per 4’x8’
board
32 HD or Concrete
fasteners per 4’x8’
board
32 AP or HD fasteners
per 4’x8’ board
UltraPly XR
100, 115, 135
membrane
UltraPly XR
100 or 115 membrane
ISO Spray S or XR
Stick, 6” on center
A
289292-0-0
ISO Spray S or XR
Stick, 4” on center
A
289295-0-0
UltraPly XR
100, 115, 135
membrane
ISO Spray S or XR
Stick, 4” on center
A
292137-0-0
1-90
1-165
1-165
Steel,
22-18
gauge,
Grade C
Concrete
1-285
Concrete
1-285
Steel,
22-18
gauge,
Grade C
Firestone Fully Adhered Uplift Ratings
New Construction, Steel or Concrete Deck, Insulation with Coverboard, UltraPly XR membrane
Uplift
Deck
Type
Insulation And
Attachment
1-60
Steel,
22-16
gauge,
Grade C
ISO 95+ GL,
1.5”-12”, 16 AP
or HD fasteners
per 4’x8’ boards
Coverboard
FiberTop
(C,E,S), 1/2”1” Thickness
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
Hot asphalt, full
application
UltraPly TPO
XR 100 or 115
membrane
XR Bonding
Adhesive
A
243484-0-0
27 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
Uplift
Deck
Type
Insulation And
Attachment
1-75
Steel,
22-16
gauge,
Grade C
ISO 95+ GL,
1.5”-12”, Loose
Laid
1-90
Steel,
22-16
gauge,
Grade C
ISO 95+ GL, 1”12”, Loose Laid
1-90
Concrete
ISO 95+ GL,
1.5”-4”, Loose
Laid
1-90
Steel,
22-16
gauge,
Grade C
ISO 95+ GL,
1.5”-12”, Loose
Laid
1-90
Concrete
ISO 95+ GL,
1.5”-4”, Loose
Laid
FiberTop E
1/2” minimum
1-90
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
ISO 95+ GL,
1.5”-12”, Loose
Laid
ISOGard HD,
½” minimum
ISO 95+ GL,
1.5”-4”, 4’x8’
board
OSB, 7/16”
thickness
16 AP or HD
fasteners per
4’x8’ boards
1-90
Concrete
ISO 95+ GL,
1.5”-4”, 4’x8’
boards,
OSB, 7/16”
thickness
1-120
Concrete
ISO 95+ GL,
2.0”-12”, 20 AP
or HD fasteners
per 4’x8’ boards
DensDeck
Prime or
SECUROCK,
½”
minimum
1-120
Steel,
22-18
gauge,
Grade C
ISO 95+ GL,
1.5”-4”, 20 AP or
HD fasteners per
4’x8’ boards
DensDeck
Prime or
SECUROCK,
½”
minimum
16 HD or
concrete Drive
fasteners per
4’x8’ boards
Firestone I.S.O.
Fix or Fix II,
I.S.O. Spray S,
I.S.O. Twin
Pack, or I.S.O.
Stick Insulation
Adhesive, 6” on
center, 4’x4’
board
Firestone I.S.O.
Fix or Fix II,
I.S.O. Spray S,
I.S.O. Twin
Pack, or I.S.O.
Stick Insulation
Adhesive, 6” on
center, 4’x4’
board
1-90
Coverboard
DensDeck,
1/4”
Minimum or
SECUROCK,
1/2”
Minimum.
DensDeck
Prime, 1/4”
Minimum.
SECUROCK,
½”
minimum
DensDeck
Prime or
SECUROCK,
1/4”
Minimum.
FiberTop
(C,E,S), 1/2”
minimum
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
15 AP or HD
fasteners per
4’x8’ boards
UltraPly TPO
XR 100 or 115
membrane
Water Based
Bonding
Adhesive - S
A
243485-0-0
12 AP fasteners
per 4’x8’ boards
UltraPly TPO
XR 100 or 115
membrane
ISO Spray S or
XR Stick, 12” on
center
A
243482-0-0
16 HD or
concrete Drive
fasteners per
4’x8’ boards
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 12” on
center
A
292001-0-0
16 AP fasteners
per 4’x8’ boards
UltraPly TPO
XR 100 or 115
membrane
XR Bonding
Adhesive
A
243483-0-0
16 HD or
concrete Drive
fasteners per
4’x8’ boards
15 AP or HD
fasteners per
4’x8’ boards
UltraPly TPO
XR 100, 115,
or 135
membrane
UltraPly TPO
XR 100, 115,
or 135
membrane
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 12” on
center
A
291988-0-0
ISO Spray S or
XR Stick, 12” on
center
A
320509-0-0
ISO Spray S or
XR Stick, 12” on
center
A
291981-0-0
UltraPly TPO
XR 100, 115,
or 135
membrane
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 12” on
center
A
289274-0-0
ISO Spray S or
XR Stick, 6” on
center
A
289300-0-0
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 6” on
center
A
292145-0-0
28 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
Uplift
Deck
Type
Insulation And
Attachment
Coverboard
1-165
Steel,
22-18
gauge,
Grade C
ISO 95+ GL,
2.0”-12”, 20 HD
or AP fasteners
per 4’x8’ boards
ISOGard HD,
½” minimum
1-165
Concrete
ISO 95+ GL,
2.0”-12”, 20 HD
or Concrete
fasteners per
4’x8’ boards
ISOGard HD,
½” minimum
1-255
Concrete
ISO 95+ GL, 2”–
4”, 32 HD or
Concrete
fasteners per
4’x8’ boards
DensDeck
Prime or
SECUROCK,
½”
minimum
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
Firestone I.S.O.
Fix, I.S.O.
Spray S, I.S.O.
Twin Pack, or
I.S.O. Stick
Insulation
Adhesive, 6” on
center, 4’x4’
board
Firestone I.S.O.
Fix, I.S.O.
Spray S, I.S.O.
Twin Pack, or
I.S.O. Stick
Insulation
Adhesive, 6” on
center, 4’x4’
board
Firestone I.S.O.
Fix or Fix II,
I.S.O. Spray S,
I.S.O. Twin
Pack, or I.S.O.
Stick Insulation
Adhesive, 4” on
center, 4’x4’
board
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 6” on
center
A
320536-0-0
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 6” on
center
A
320464-0-0
UltraPly TPO
XR 100, 115,
or 135
membrane
ISO Spray S or
XR Stick, 4” on
center
A
289296-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Concrete Deck, Adhered Coverboard Only, UltraPly XR membrane
Uplift
Deck
Type
1-465
Concrete
1-720
Concrete
Coverboard
DensDeck Prime or
SECUROCK, ¼”
thickness, 4’x4’
boards
ISOGard HD, ½”
thickness, 4’x4’
boards
Coverboard Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
Hot Asphalt
UltraPly TPO XR 100
or 115 membrane
XR Bonding
Adhesive
A
243447-0-0
4” o.c. bead spacing with
ISO Fix/Fix II or ISO
Stick/Stick Green
UltraPly TPO XR 100
or 115 membrane
XR Bonding
Adhesive
A
261317-0-0
Firestone Fully Adhered Uplift Ratings
New Construction, Concrete Deck, UltraPly XR membrane
Uplift
Deck Type
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-840
1-720
1-945
1-975
Concrete
Concrete
Concrete
Concrete
UltraPly TPO XR 115
Ultraply TPO XR 115 or 135
UltraPly TPO XR 100, 115, or 135
UltraPly TPO XR 115 or 135
Water Based Bonding Adhesive-S
XR Bonding Adhesive
XR Spray S, full coverage
Hot Asphalt
A
A
A
A
242960-0-0
242966-0-0
293219-0-0
243438-0-0
29 | P a g e
February 2014
Firestone Fully Adhered Uplift Ratings
New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR membrane
Uplift
Deck Type,
Vapor
Barrier
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-345
Concrete,
with
mopped
vapor
barrier*
ISOGard HD, ½”-1”
thickness, 4’x4’ boards
Firestone I.S.O. Fix or Fix II,
I.S.O. Spray S, I.S.O. Twin
Pack, or I.S.O. Stick
Insulation Adhesive, 12” on
center, 4’x4’ board
UltraPly TPO
XR 100,
115, 135
ISO Spray S or
XR Stick, full
coverage
A
292419-0-0
DensDeck Prime or
292418-0-0
SECUROCK, ¼”
thickness, 4’x4’ boards
*One or two plies of Firestone Type IV (4)M or Type VI(6)M Ply Felt or one ply of MB Base, SBS Base, SBS Polybase or SBS Premium Base
fully adhered to structural deck with a full mopping of hot asphalt.
Firestone Fully Adhered Uplift Ratings
New Construction, Lightweight Insulated Concrete, UltraPly XR membrane
Uplift
Deck Type
Lightweight Manufacturer
Membrane
1-60
Concrete
1-420
Concrete
1-210
Concrete
1-180
Concrete
Range II Elastizell Lightweight
Insulating Concrete
Range II Elastizell Lightweight
Insulating Concrete
Celcore MF Cellular Concrete with
Celcore- HS Rheology Modifying
Admixer, Wet cast 40 lbs/ft³
Celcore- HS Rheology Modifying
Admixer, Wet cast 40 lbs/ft³
UltraPly
or 115
UltraPly
or 115
UltraPly
or 115
TPO XR 100
membrane
TPO XR 100
membrane
TPO XR 100
membrane
UltraPly TPO XR 100
or 115 membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav Assembly
Number
Water Based Bonding
Adhesive - S
XR Bonding Adhesive
A
244666-0-244657
A
244665-0-244657
Water Based Bonding
Adhesive - S
A
244650-0-244646
XR Bonding Adhesive
A
244648-0-244646
Firestone Fully Adhered Uplift Ratings
Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, Without Coverboard
Uplift
Deck
Type
Insulation
Insulation Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Gypsum
ISO 95+ GL, 1” thickness,
4’x4’ boards
12” o.c. beads of Twin Pack
Adhesive
UltraPly TPO
membrane
UltraPly or
Single Ply
LVOC Bonding
Adhesive
A
319860-0-0
Firestone Fully Adhered Uplift Ratings
Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Coverboard
Uplift
Deck
Type
Insulation
Insulation
Attachment
Coverboard
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Gypsum
None
None
DensDeck or
SECUROCK,
¼” minimum,
4’x4’ boards
12” o.c.
beads of
Twin Pack
Adhesive
UltraPly
TPO
membrane
A
113400-0-0
1-90
Gypsum
ISO 95+
GL, .5”12”, 4’x4’
boards
12” o.c.
beads of
I.S.O.
Stick/Stick
Green
Adhesive
DensDeck or
DensDeck
Prime, ¼”
minimum,
4’x4’ boards
12” o.c.
beads of
I.S.O.
Stick/Stick
Green
Adhesive
UltraPly
TPO
membrane
UltraPly, Water
Based Bonding
Adhesive-S/P or
Single Ply LVOC
Bonding
Adhesive
UltraPly, Water
Based Bonding
Adhesive-S/P or
Single Ply LVOC
Bonding
Adhesive
A
115286-0-0
30 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane
New Construction, Steel, Mechanically Attached Insulation, Single Weld
Uplift
Deck
Type
Insulation and Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Steel,
22-18
gauge,
Grade E
Steel,
22-16
gauge,
Grade C
Steel,
22-18
gauge,
Grade E
Steel,
22-18
gauge,
Grade E
Steel,
20-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
Steel,
22-18
gauge,
Grade E
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
UltraPly TPO or
ReflexEON
membrane, 10’ Sheet
12” o.c. HD fastener and HD or
Barbed Seam Plate, Single weld
A
3080-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
UltraPly TPO
membrane, 10’ Sheet
12” o.c. HD fastener and HD Seam
Plate, Single weld
A
170476-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
UltraPly TPO or
ReflexEON
membrane, 8’ Sheet
12” o.c. HD fastener and HD Seam
Plate, Single weld
A
76731-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement or
ISO 95+ GL (Tapered) 1.5”-4”
UltraPly TPO or
ReflexEON
membrane, 10’ Sheet
12” o.c. HD+ fastener and HD+
Seam Plate, Single weld
A
76911-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
UltraPly TPO
membrane, 10’ Sheet
6” o.c. HD fastener and HD or
Barbed Seam Plate, Single weld
A
166431-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
UltraPly TPO or
ReflexEON
membrane, 8’ Sheet
12” o.c. HD+ fastener and HD+
Seam Plate, Single weld
A
213747-0-0
ISO 95+ GL, 1.5”-12”,
Preliminary Securement or
ISO 95+ GL (Tapered) 1.5”-4”
UltraPly TPO or
ReflexEON
membrane, 10’ Sheet
6” o.c. HD fastener and HD or
Barbed Seam Plate, Single weld
A
3081-0-0
ISO 95+ GL, 1”-12”,
Preliminary Securement
UltraPly TPO or
ReflexEON
membrane, 6’ 6”
Sheet
UltraPly TPO
membrane, 8’ Sheet
6” o.c. HD fastener and HD Plate,
Single weld
A
3074-0-0
6” o.c. HD+ fastener and HD+
Seam Plate, Single weld
A
343455-0-0
UltraPly TPO 120
membrane, 10’ Sheet
6” o.c. HD+ fastener and HD+
Seam Plate, Single weld
A
343459-0-0
1-60
1-90
1-90
1-90
1-90
1-105
1-105
1-135
1-135
Steel,
22-18
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO 95+
GL (tapered) .5”-4”
Preliminary Securement
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO 95+
GL (tapered) .5”-4”
Preliminary Securement
Firestone Mechanically Attached Systems Uplift Ratings
New Construction, Steel, Insulation with Coverboard, Single Weld
Uplift
Deck
Type
Insulation and Attachment
Coverboard and
Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Steel,
22-16
gauge,
Grade C
ISO 95+ GL, 1”-12”,
Preliminary Securement
DensDeck,
DensDeck Prime,
or SECUROCK,
¼” min.
UltraPly TPO or
ReflexEON
membrane, 10’
Sheet
A
264245-0-0
1-60
Steel,
22-16
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
ISOGard HD, ½”
thickness
UltraPly TPO or
ReflexEON
membrane, 10’
Sheet
12” o.c. HD fastener
and HD Seam Plate or
UltraPly TPO Barbed
Seam Plate, Single
weld
12” o.c. HD fastener
and HD Seam Plate,
Single weld
A
266089-0-0
31 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings
Uplift
Deck
Type
Insulation and Attachment
Coverboard and
Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-75
Steel,
22-18
gauge,
Grade C
DensDeck or
SECUROCK, ¼”
min.
UltraPly TPO or
ReflexEON
membrane, 8’
Sheet
12” o.c. HD fastener
and HD Seam Plate,
Single weld
A
339004-0-0
1-75
Steel,
22-18
gauge,
Grade C
ISOGard HD, ½”
thickness
UltraPly TPO or
ReflexEON
membrane, 8’
Sheet
12” o.c. HD fastener
and HD Seam Plate,
Single weld
A
338538-0-0
1-90
Steel,
22-18
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO
95+ GL (tapered) .5”-4”
Preliminary Securement
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO
95+ GL (tapered) .5”-4”
Preliminary Securement
ISO 95+ GL, 1”-12”,
Preliminary Securement
DensDeck or
SECUROCK, ¼”
min.
UltraPly TPO
membrane, 6’ 6”
Sheet
A
339174-0-0
1-90
Steel,
22-18
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement
ISOGard HD, ½”
thickness.
UltraPly TPO
membrane, 6’ 6”
Sheet
6” o.c. HD fastener
and HD Seam Plate or
UltraPly TPO Barbed
Seam Plate, Single
weld
12” o.c. HD fastener
and HD Seam Plate,
Single weld
A
339172-0-0
1-105
Steel,
22-18
gauge,
Grade C
DensDeck or
SECUROCK, ¼”
min.
UltraPly TPO
membrane,10’
Sheet
6” o.c. HD fastener
and HD Seam Plate,
Single weld
A
343411-0-0
1-105
Steel,
22-18
gauge,
Grade C
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO
95+ GL (tapered) .5”-4”
Preliminary Securement
ISO 95+ GL, 1.5”-12”,
Preliminary Securement.
Optional top layer of ISO
95+ GL (tapered) .5”-4”
Preliminary Securement
ISOGard HD, ½”
thickness.
UltraPly TPO
membrane,10’
Sheet
6” o.c. HD fastener
and HD Seam Plate,
Single weld
A
343408-0-0
Firestone Mechanically Attached Systems Uplift Ratings
New Construction, Concrete, Insulation with Coverboard, Single Weld
Uplift
Deck
Type
Insulation and
Attachment
Coverboard and
Attachment
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Concrete
ISO 95+ GL, 1.5”12”, Loose Laid
FiberTop C,E or S,½”
min.
DensDeck or SECUROCK,
¼” min.
ISOGard HD, ½”
thickness
FiberTop C,E or S,½”
min.
DensDeck or SECUROCK,
¼” min.
ISOGard HD, ½”
thickness
UltraPly TPO
ReflexEON
membrane, 10’
Sheet
12” o.c. HD fastener
and HD Seam Plate or
UltraPly TPO Barbed
Seam Plate, Single
weld
A
269752-0-0
6” o.c. HD fastener
and HD Seam Plate or
UltraPly TPO Barbed
Seam Plate, Single
weld
A
1-75
Concrete
ISO 95+ GL, 1.5”12”, Loose Laid
UltraPly TPO 120
or ReflexEON
membrane, 10’
Sheet
269751-0-0
269750-0-0
269743-0-0
269742-0-0
269741-0-0
32 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings
Recover, Metal Building, Insulation with Coverboard
Uplift
Deck Type
Flute Filler
Insulation
and
Attachment
Coverboard and
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Standing/L
ap Seam
Roof
(Insulated)
ISO 95+ GL, 1”
ISO 95+
GL, .5”-1”
thickness
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
DensDeck/DensDeck
Prime or
SECUROCK, ¼” min.
Preliminary
Attachment
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
DensDeck/DensDeck
Prime or
SECUROCK, ¼” min.
Preliminary
Attachment
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
DensDeck/DensDeck
Prime or
SECUROCK, ¼” min.
Preliminary
Attachment
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
DensDeck/DensDeck
Prime or
SECUROCK, ¼” min.
Preliminary
Attachment
ISOGard HD, ½”
min. Preliminary
Attachment
FiberTop (C,E or S),
½” min. Preliminary
Attachment
DensDeck/DensDeck
Prime or
SECUROCK, ¼” min.
Preliminary
Attachment
UltraPly
TPO or
ReflexEON
membrane,
10’ sheet
12” o.c. with
Firestone Purlin
Fasteners and HD
Seam Plates, Single
Weld
A
305074-0-0
1-60
1-90
1-90
1-105
1-105
Standing/L
ap Seam
Roof
(Insulated)
ISO 95+ GL, 1”
minimum
Standing/L
ap Seam
Roof
(Insulated)
ISO 95+ GL, 1”
minimum
Standing/L
ap Seam
Roof
(Insulated)
ISO 95+ GL, 1”
minimum
Standing/L
ap Seam
Roof
(Insulated)
Standing/L
ap Seam
Roof
(Insulated)
ISO 95+ GL, 1”
minimum
ISO 95+ GL, 1”
minimum
ISO 95+
GL, .5”-1”
thickness
ISO 95+
GL, .5”-1”
thickness
ISO 95+
GL, .5”-1”
thickness
ISO 95+
GL, 1”-4”
thickness
ISO 95+
GL, .5”-1”
thickness
305078-0-0
305080-0-0
UltraPly
TPO or
ReflexEON
membrane,
6’ 6” sheet
12” o.c. with
Firestone Purlin
Fasteners and Metal
Batten Strip, Wide
Weld
A
305058-0-0
305059-0-0
305060-0-0
UltraPly
TPO or
ReflexEON
membrane,
8’ sheet
12” o.c. with
Firestone Purlin
Fasteners and HD
Seam Plates, Single
Weld
A
UltraPly
TPO or
ReflexEON
membrane,
10’ sheet
UltraPly QuickSeam
RMA Strips secured
to purlins at 6” o.c.
with Firestone
Purlin Fasteners
and Metal Batten
Strip, Single Weld
A
6” o.c. with
Firestone Purlin
Fasteners and HD
Seam Plates, Single
Weld
A
UltraPly
TPO 148 or
ReflexEON
membrane,
12’4” sheet
305221-0-0
305222-0-0
305226-0-0
305227-0-0
305228-0-0
265291-0-0
265293-0-0
265296-0-0
UltraPly
TPO 148 or
ReflexEON
membrane,
12’4” sheet
6” o.c. with
Firestone Purlin
Fasteners and HD
Seam Plates, Single
Weld
A
305233-0-0
305234-0-0
305237-0-0
33 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings – UltraPly XR 100 and XR 115
Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld
Uplift
Deck Type
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Steel, Any
thickness/class,
Recover
Steel, Any
thickness,
Class E,
Recover
Steel, Any
thickness/class,
Recover
Steel, Any
thickness/class,
Recover
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
12” o.c. HD fastener and HD Seam Plate,
Single weld
A
242937-0-0
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
12” o.c. HD+ fastener and HD+ Seam
Plate, Single weld
A
242946-0-0
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
6” o.c. HD fastener and HD+ Seam Plate,
Single weld
A
242950-0-0
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
6” o.c. HD+ fastener and HD+ Seam
Plate, Single weld
A
242951-0-0
1-90
1-90
1-135
Firestone Mechanically Attached Systems Uplift Ratings
Recover, Concrete Deck, UltraPly TPO XR membrane, Single Weld
Uplift
Deck Type
Membrane
Membrane Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-60
Concrete, Recover
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
12” o.c. HD fastener and HD Seam Plate,
Single weld
A
242935-0-0
1-90
Concrete, Recover
UltraPly TPO XR 100, 115, 135
membrane, 10’ Sheet
6” o.c. HD fastener and HD Seam Plate,
Single weld
A
242949-0-0
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System
Invisiweld System, Induction Welded
Uplift
Deck
Type
Insulation and
Attachment
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-90
Steel,
22-16
gauge,
Grade C
Steel,
22-16
gauge,
Grade C
ISO 95+ GL,
1.5”-12”
Thickness
None
A
250651-0-0
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck or
SECUROCK, ¼”
min.
None
UltraPly TPO or
ReflexEON
membrane, Single
weld
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
ISO 95+ GL,
1.5”-12”
Thickness
6 HD fasteners
and Invisiweld
Plates per 4’x8’
board
6 HD fasteners
and Invisiweld
Plates per 4’x8’
board
Invisiweld
System
A
277975-0-0
1-90
1-90
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
1-90
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
277978-0-0
277977-0-0
6 HD or Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
6 HD Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
250819-0-0
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
251831-0-0
251817-0-0
251833-0-0
34 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System
Uplift
Deck
Type
Insulation and
Attachment
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-120
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
ISO 95+ GL,
1.5”-12”
Thickness
None
A
254071-0-0
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
None
UltraPly TPO or
ReflexEON
membrane, Single
weld
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
ISO 95+ GL,
1.5”-12”
Thickness
8 HD fasteners
and Invisiweld
Plates per 4’x8’
board
8 HD fasteners
and Invisiweld
Plates per 4’x8’
board
Invisiweld
System
A
278050-0-0
1-120
1-120
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
1-120
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
1-150
1-150
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
ISO 95+ GL,
1.5”-12”
Thickness
ISO 95+ GL,
1.5”-12”
Thickness
1-150
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
1-150
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
1-210
1-210
Steel,
22-18
gauge,
Grade C
Steel,
22-18
gauge,
Grade C
ISO 95+ GL,
1.5”-12”
Thickness
ISO 95+ GL,
1.5”-12”
Thickness
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
None
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
None
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
None
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck or
SECUROCK, ¼”
min.
278052-0-0
278051-0-0
8 HD or Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
8 HD Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254075-0-0
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254077-0-0
12 HD fasteners
and Invisiweld
Plates per 4’x8’
board
12 HD fasteners
and Invisiweld
Plates per 4’x8’
board
UltraPly TPO or
ReflexEON
membrane, Single
weld
UltraPly TPO or
ReflexEON
membrane, Single
weld
254076-0-0
254078-0-0
Invisiweld
System
A
253954-0-0
Invisiweld
System
A
254054-0-0
254053-0-0
254055-0-0
12 HD or
Concrete Drive
fasteners and
Invisiweld Plates
per 4’x8’ board
12 HD Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
16 HD fasteners
and Invisiweld
Plates per 4’x8’
board
16 HD fasteners
and Invisiweld
Plates per 4’x8’
board
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254056-0-0
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254058-0-0
254057-0-0
254059-0-0
UltraPly TPO or
ReflexEON
membrane, Single
weld
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254090-0-0
Invisiweld
System
A
278065-0-0
278067-0-0
278066-0-0
35 | P a g e
February 2014
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System
Uplift
Deck
Type
Insulation and
Attachment
Coverboard
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-210
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
None
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254112-0-0
1-210
Concrete
– New
and
Recover
ISO 95+ GL,
1.5”-12”
Thickness
FiberTop (C,E
or S), ½” min.
ISOGard HD,
½” min.
DensDeck/Dens
Deck Prime, or
SECUROCK, ¼”
min.
16 HD or
Concrete Drive
fasteners and
Invisiweld Plates
per 4’x8’ board
16 HD Concrete
Drive fasteners
and Invisiweld
Plates per 4’x8’
board
UltraPly TPO or
ReflexEON
membrane, Single
weld
Invisiweld
System
A
254117-0-0
254115-0-0
254119-0-0
Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System
Recover, Metal Building, Invisiweld System, Induction Welded
Uplift
Deck
Type
Flute Filler
Insulation
Attachment
Membrane
Membrane
Attachment
Exterior
Fire
Rating
RoofNav
Assembly
Number
1-105
Steel –
Standing
Seam
ISO 95+ GL,
1”-4”
thickness
ISO 95+ GL, 1.5”-4”
thickness, 5 HD
fasteners and Insulation
Plates per 4’x8’ board
UltraPly TPO
or ReflexEON
membrane,
Single weld
Induction
Welded
A
253893-0-0
1-105
Steel –
Standing
Seam
ISO 95+ GL,
1”-4”
thickness
ISOGard HD, ½”
thickness, 5 HD
fasteners and Insulation
Plates per 4’x8’ board
UltraPly TPO
or ReflexEON
membrane,
Single weld
Induction
Welded
A
253890-0-0
1-105
Steel –
Standing
Seam
ISO 95+ GL,
1”-4”
thickness
FiberTop, ½”-1”
thickness, 5 HD
fasteners and Insulation
Plates per 4’x8’ board
UltraPly TPO
or ReflexEON
membrane,
Single weld
Induction
Welded
A
253897-0-0
1-105
Steel –
Standing
Seam
ISO 95+ GL,
1”-4”
thickness
DensDeck/DensDeck
Prime, or SECUROCK,
¼” min., 5 HD fasteners
and Insulation Plates
per 4’x8’ board
6” on center
Purlin fastener
and Invisiweld
Plate, 120” row
spacing
6” on center
Purlin fastener
and Invisiweld
Plate, 120” row
spacing
6” on center
Purlin fastener
and Invisiweld
Plate, 120” row
spacing
6” on center
Purlin fastener
and Invisiweld
Plate, 120” row
spacing
UltraPly TPO
or ReflexEON
membrane,
Single weld
Induction
Welded
A
253900-0-0
Factory Mutual Ballast Guidelines
FM RECOMMENDED BALLAST WEIGHT (LB/SQ FT) FOR ROOF FIELD/PERIMETERS/CORNERS
Ground Roughness B
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 89
10/12/15
>89 ≤ 130
12/15/18
>130 - ?
See Note 1
Steel or pre-cast panel deck with ≤ 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 60
>0 ≤ 60
10/12/15
12/15/15
>60 ≤ 89
>60 ≤ 89
12/15/15
12/15/18
>89 - ?
>89 - ?
See Note 1
See Note 1
110 mph
Roof Height
Ballast
weights
>0 ≤ 30
12/15/15
>30 ≤ 55
12/15/18
>55 - ?
See Note
36 | P a g e
February 2014
Ground Roughness B
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 89
10/10/12
>89 ≤ 130
12/12/15
>130 ≤ 220
12/15/18
>220 -?
See Note 1
Steel or pre-cast panel deck with > 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 60
>0 ≤ 60
10/10/12
12/12/12
>60 ≤ 89
>60 ≤ 89
12/12/12
12/12/15
>89 ≤ 150
> 89 - ?
12/15/18
See Note 1
>150 - ?
See Note 1
110 mph
Roof Height
Ballast
weights
>0 ≤ 30
12/12/12
>30 ≤ 55
12/12/15
>55 ≤ 89
12/15/18
> 89 - ?
See Note 1
Ground Roughness B
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 89
10/10/10
>89 ≤ 130
12/12/15
>130 ≤ 220
12/15/18
>220 - ?
See Note 1
Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 60
>0 ≤ 60
>0 ≤ 30
10/10/10
10/12/12
10/12/12
>60 ≤ 89
>60 ≤ 89
>30 ≤ 55
10/12/12
12/12/15
12/12/15
>89 ≤ 140
>89 - ?
>55 ≤ 89
12/15/18
See Note 1
12/15/18
>140 - ?
>89 - ?
See Note 1
See Note 1
Ground Roughness B
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 89
10/10/10
>89 ≤ 130
12/12/12
>130 ≤ 220
12/12/15
>220 -500
15/15/18
Cementitious Wet Fill (Concrete) deck with > 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 60
>0 ≤ 60
>0 ≤ 30
10/10/10
10/10/12
10/10/12
>60 ≤ 89
>60 ≤ 89
>30 ≤ 55
10/10/12
12/12/12
12/12/12
>89 ≤ 140
> 89 ≤ 165
>55 ≤ 89
12/12/15
15/15/18
12/12/15
>140 - 350
>165 - ?
> 89 - ?
15/15/18
See Note 2
See Note 2
Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater.
Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater.
Ground Roughness C
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 25
10/12/15
>25 ≤ 75
12/15/15
>75 ≤ 89
12/15/18
>89 - ?
See Note 1
Steel or pre-cast panel deck with ≤ 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 15
>0 ≤ 15
10/12/15
12/15/15
>15 ≤ 45
>15 ≤ 35
12/15/15
12/15/18
>45 ≤ 89
>35 - ?
12/15/18
See Note 1
>89 - ?
See Note 1
110 mph
Roof Height
Ballast
weights
>0 ≤ 15
12/12/15
>15 - ?
See Note 1
Ground Roughness C
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 25
10/10/12
>25 ≤ 75
12/12/12
>75 ≤ 89
12/12/15
>89 ≤ 90
12/15/18
>90 - ?
See Note 1
Steel or pre-cast panel deck with > 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 15
>0 ≤ 15
10/10/12
12/12/12
>15 ≤ 45
>15 ≤ 35
12/12/12
12/12/15
>45 ≤ 89
>35 ≤ 70
12/12/15
12/15/18
>89 - ?
>70 - ?
See Note 1
See Note 1
110 mph
Roof Height
Ballast
weights
>0 ≤ 15
12/12/15
>15 ≤ 30
12/15/18
>30 - ?
See Note 1
Ground Roughness C
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 25
10/10/10
>25 ≤ 75
10/12/12
>75 ≤ 89
12/12/15
>89 ≤ 90
12/15/18
Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 15
>0 ≤ 15
>0 ≤ 15
10/10/10
10/12/12
12/12/15
>15 ≤ 45
>15 ≤ 35
>15 ≤ 30
10/12/12
12/12/15
12/15/18
>45 ≤ 89
>35 ≤ 70
>30 - ?
12/12/15
12/15/18
See Note 1
>89 - ?
>70 - ?
See Note 1
See Note 1
37 | P a g e
February 2014
Ground Roughness C
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 25
10/10/10
>25 ≤ 75
10/10/12
>75 ≤ 89
12/12/12
>89 ≤ 90
12/12/15
>90 ≤ 275
15/15/18
Cementitious Wet Fill (Concrete) deck with > 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 15
>0 ≤ 15
>0 ≤ 15
10/10/10
10/10/12
12/12/12
>15 ≤ 45
>15 ≤ 35
>15 ≤ 30
10/10/12
12/12/12
12/12/15
>45 ≤ 89
>35 ≤ 70
>30 ≤ 89
12/12/12
12/12/16
15/15/18
>89 ≤ 165
>70 ≤ 89
>89 - ?
15/15/18
15/15/18
See Note 2
>165 - ?
>89 - ?
See Note 2
See Note 2
Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater.
Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater.
Ground Roughness D
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 30
12/15/15
>30 ≤ 89
12/15/18
>89 - ?
See Note 1
Steel or pre-cast panel deck with ≤ 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 15
>0 ≤ 15
12/15/15
12/15/18
>15 ≤ 50
>15 - ?
12/15/18
See Note 1
>50 - ?
See Note 1
110 mph
Roof Height
Ballast
weights
N/A
See Note 1
Ground Roughness D
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 30
12/12/12
>30 ≤ 89
12/12/15
>89 - ?
See Note 1
Steel or pre-cast panel deck with > 36” parapet
90 mph
100 mph
Roof Height
Ballast
Roof Height
Ballast
weights
weights
>0 ≤ 15
>0 ≤ 15
12/12/12
12/12/15
>15 ≤ 50
>15 ≤ 35
12/12/15
12/15/18
>50 ≤ 89
>35 - ?
12/15/18
See Note 1
>89 - ?
See Note 1
110 mph
Roof Height
Ballast
weights
N/A
See Note 1
Ground Roughness D
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 30
10/12/12
>30 ≤ 89
12/12/15
>89 - ?
See Note 1
Cementitious Wet Fill (Concrete) deck with ≤ 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 15
>0 ≤ 15
10/12/12
12/12/15
N/A
See Note 1
>15 ≤ 50
>15 ≤ 35
12/12/15
12/15/18
>50 ≤ 89
>35 - ?
12/15/18
See Note 1
>89 - ?
See Note 1
Ground Roughness D
≤85 mph
Roof Height
Ballast
(ft)
weights
>0 ≤ 30
10/10/12
>30 ≤ 89
12/12/12
>89 ≤ 165
15/15/18
>165 - ?
See Note 2
Cementitious Wet Fill (Concrete) deck with > 36” parapet
90 mph
100 mph
110 mph
Roof Height
Ballast
Roof Height
Ballast
Roof Height
Ballast
weights
weights
weights
>0 ≤ 15
>0 ≤ 15
>0 ≤ 45
10/10/12
12/12/12
15/15/18
>15 ≤ 50
>15 ≤ 35
>45 - ?
12/12/12
12/12/15
See Note 2
>50 ≤ 89
>35 ≤ 89
12/12/15
15/15/18
>89 ≤ 90
>89 - ?
15/15/18
See Note 2
>90 - ?
See Note 2
Note 1: Use an Adhered or Mechanically attached system that is rated for 90 psf or greater.
Note 2: Use an Adhered or Mechanically attached system that is rated for 105 psf or greater.
38 | P a g e
February 2014
Download