XIX. UL & FM
1.
General Notes
PROPRIETARY
Bilco information for Authorized Personnel
Only. Not to be Reproduced.
Technical
Data Sheet
UL and FM
UL Listed and FM approved units
SIZE
STEEL
STEEL/ALUM
ALL ALUM
POLYCARB
4x4
DSH4848
DSH4848A
DSH4848B
LV4848B
DSH4872
DSH4872A
DSH4872B
DSH4890
DSH4890A
DSH4890B
4x8
DSH4896
DSH4896A
DSH4896B
5x5
DSH6060
DSH6060A
DSH6060B
5x6
DSH6072
DSH6072A
DSH6072B
5x7
DSH6084
DSH6084A
DSH6084B
5x8
DSH6096
DSH6096A
DSH6096B
DSH60120
DSH60120A
DSH60120B
DSH6666
DSH6666A
DSH6666B
56 x 12
DSH66144
DSH66144A
DSH66144B
6x6
DSH7272
DSH7272A
DSH7272B
4x6
4x7
6
5 x 10
6
5 x5
6
LV4896B
LV6096B
The above are the only units that may carry the UL listing. FM labels can be provided for all sizes between
those listed above and some larger sizes.
Options
Electric Release (Electric Thermolatch or Wall Mounted Electric Rigging Release)
-
No UL listing, unless they use an MCABE link.
-
In order to carry the FM label, each vent must be energized separately. This means that if the
units are to be energized by smoke detectors, each vent must have its own smoke detector and
each detector must be located at the vent it is to activate. For panel control each unit must be
individually energized and controlled uniquely.
Motorized Fire Vents and Motorized Acoustical Fire Vents
-
No UL listing
-
FM label would not be affected with the addition of motorized operation for regular FM
approved Fire Vents and Acoustical Fire Vents.
Domed Fire Vents
-
No UL listing.
-
No FM approval.
UL & FM.doc
PROPRIETARY
Bilco information for Authorized Personnel
Only. Not to be Reproduced.
1/4/02
Technical
Data Sheet
UL and FM
Single Leaf Fire Vents
-
No UL or FM approval standards have been developed for single leaf units.
Explosion Vents
-
No UL or FM label.
Acoustical Fire Vents
-
Acoustical Fire Vents are FM approved only. They can not be UL listed.
-
Any 10 psf (0.479 KN/m2) Double Leaf (all steel) Acoustical Smoke Vent can be labeled FM
approved and be called ACDSH.
Rigged Fire Vents and Rigged Acoustical Fire Vents
-
The addition of Winch operation to regular FM approved Fire Vents or Acoustical Fire Vents
does not alter the FM label.
-
There is no UL listing for rigged Fire Vents or Acoustical.
Special Curbs – All UL and FM Approved
1.
Fully Enclosed curbs.
2.
Curbs modified for roof configurations.
3.
Tapered curbs to fit a sloped roof.
PROPRIETARY
Bilco information for Authorized Personnel
Only. Not to be Reproduced.
UL & FM.doc
1/4/02
Technical
Data Sheet
UL and FM
What does UL listed and FM approved Mean?
Both Underwriters Laboratory Inc. (UL) and Factory Manual Research Corporation (FM) are
independent, non-profit organizations that test products to be sure that they meet certain standards. Once
tested and approved (or listed) the manufacturing procedures and processes must not be changed and must
be periodically checked to assure compliance. UL and FM certification is not required by law; however,
customers often look for this certification before they buy.
Requirements and Test Procedures
1.
Bilco submits drawings and calculations for FM engineering review.
2.
Tests
A. Melt Fusible Link.
B. Manual operation using inside and outside manual pull release cables without disturbing
the fusible link.
C. Cycles – Unit operated 60 cycles to evaluate reliability and service life.
D. After opening, hold open arms checked for positive hold open in 90 degrees full open
position.
E. Simulated wind uplift – Covers must withstand 30-psf (1.435KN/m2) uplift for one
minute and remain closed.
F.
Simulated horizontal wind load – Covers must open and remain open when subjected to
45-mph (72Km/hr) wind load (5 psf (0.240KN/m2) horizontal load).
G. Simulated snow load – Covers must open and lock when subjected to 10-psf
(0.479KN/m2) exterior loading on cover.
H. Live load – Covers must structurally support a 40-psf (1.915KN/m2) live load.
I.
Units will be clearly labeled with manufacturer’s name and address, model name, FM
approved symbol, the words “Factory Mutual Approved” and the words “Snow Rated 10psf”.
J.
3.
Each vent shall also be clearly marked “Operate Immediately Following Installation”
Manufacturer’s responsibility is to build according to submitted drawings. Manufacturer
must notify FM of any changes and get permission for those changes.
4.
Inspections – FM will conduct periodic inspections to assure that units are being
manufactured as originally approved.
Note: UL inspects 4 times a year; FM inspects once per year.