Technical Information Lamp Data - Light tubes Light tubes Light tubes produce light when a starter generates an electrical pulse, which starts a discharge of gas in the tube. This discharge generates ultraviolet light that is transformed into visible light when it meets the fluorescent coating (light powder) in the tubes glass wall. Different light powders dictate the spectral characteristics. A current through the tube limits/increases the discharge process and so defines the luminous efficacy. Ljuskälledata – Lysrör Figure Type T5, Tube Ra>80 Economic lifetime 19000 hr ILCOS FDH ZVEI T16 Base G5 T5, Tube for cold surroundings Ra>80 Economic lifetime 19000 hr T5, ”longlife” tube Ra>80 Economic lifetime 48000 hr T5, Tube ECO 21 000 hr T8, Tube Ra>80 Economic lifetime 17000 hr (HF) 12000 hr (F) Miniature tube Economic lifetime 8000 hr FDH FD FD T16 T26 T16 G5 G13 G5 Wattage (W) Lumen(lm)* 14 1200 96 21 1900 100 28 2600 104 35 3300 104 49 4300 100 24 1750 83 39 3100 90 54 4450 93 80 6150 80 54 4850 93 80 6800 88 28 2600 104 49 4300 100 54 4450 93 80 6150 88 13 1150 91 20 1650 83 25 2600 103 32 3100 98 45 4100 92 50 4450 92 73 6300 84 15 1000 67 18 1350 75 30 2450 82 36 3350 93 58 5200 90 8 400 50 * Lumen values for T5 at 25ºC. Maximum luminance value is at 35ºC and is 10 - 14% higher. **Luminous efficacy is at maximum lumen values. 198 Luminous eff. (lm/W)** Colour temp. (K) Item. no. 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 3000 4000 3000 4000 3000 4000 2700 4000 77000336 77000335 77000337 77000338 77000339 77000340 77000342 77000343 77000344 77000346 77000347 77000348 77000391 77000390 77000393 77000351 77000381 77000384 77000385 77000398 77000388 77000395 77000396 3000 77009010 4000 77009009 3000 77009014 4000 77009015 3000 4000 3000 4000 3000 4000 3000 4000 3000 4000 3000 3000 4000 3000 4000 3000 4000 3000 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 77000800 77000805 77000804 77000812 77000813 77000810 77000811 77000809 77000323 77000403 77000400 77000331 77000407 77000333 77000408 77000332 77000409 77000354 77000355 77000417 77000079 77000080 77000081 77000274 77000275 77000276 77000233 77000324 77000322 77000277 77000278 77000279 77000280 77000281 77000282 77000329 3000 77000298 4000 77000299 Technical Information Lamp Data - Compact light tubes Compact light tubes A compact light tube is in reality just an ordinary tube that has been bent around on itself so you only need one lamp per fitting. There are two principle types. One has built-in starter (2 pin) and the other does not (4 pin). Note that for HF ballast or integrated emergency lighting you should always use 4 pin compact tubes as the HF ballast and emergency light units have their own ”starter” built in. Lamp data – Compact light tubes TC-SEL TC-S Figure Type Compact light tubes 2 limb short 2 pin Ra>80 Economic lifetime 10000 hr Compact light tubes 2 limb short 4 pin Ra>80 Economic lifetime 13000 hr TC-L Compact light tubes 2 limb long Ra>80 4 pin Economic lifetime 20000 hr (HF) 15000 hr (F) ILCOS FSD-I FSD-E FSD-E TC-R TC-DEL TC-D FSDH-L Compact light tubes 4 limb, 2 pin Ra>80 Economic lifetime 10000 hr Compact light tubes 4 limb, 4 pin Ra>80 Economic lifetime 13000 hr Compact light tubes 6 limb, 4 pin Ra>80 Economic lifetime 13000 hr ZVEI TC-S TC-SEL TC-L TC-L Wattage (W) Lumen (lm) Luminous eff. (lm/W) 7 400 57 9 600 67 11 900 82 7 400 57 9 600 67 11 900 82 18 1250 69 24 1800 75 28 2700 96 36 2900 81 40 3500 87 55 4850 88 80 6500 81 10 600 60 13 900 69 G24d-2 18 1200 67 G24d-3 26 1800 69 10 600 60 13 900 69 G24q-2 18 1200 67 G24q-3 26 1800 69 14 1050 74 Base G23 2G7 2G11 2G11 G24d-1 FSQ-I TC-D G24q-1 FSQ-E TC-DEL TC-R GR14q 17 1250 74 Colour temp. (lm/W) Item no. 2700 3000 3000 4000 2700 3000 2700 4000 2700 4000 3000 4000 2700 3000 4000 2700 3000 4000 3000 4000 2700 3000 4000 3000 4000 3000 4000 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 3000 77000301 77000318 77000317 77000286 77000291 77000316 77000159 77001040 77000160 77000294 77000406 77000295 77000122 77000056 77000120 77000123 77000121 77000058 25103257 25103258 77000124 77000084 77000086 77000095 77000096 77000136 77000137 25103396 25103397 77000015 77000016 77000017 77000022 77000019 77000026 77000009 77000010 77000011 77000221 77000219 77000222 77000097 77000018 77000098 77000099 77000002 77000100 77000012 77000013 77000014 77000220 77000217 77000218 77001208 4000 77001209 3000 77001210 4000 77001211 199 Technical Information Lamp Data - Compact light tubes Compact light tubes A compact light tube is in reality just an ordinary tube that has been bent around on itself so you only need one lamp per fitting. There are two principle types. One has built-in starter (2 pin) and the other does not (4 pin). Note that for HF ballast or integrated emergency lighting you should always use 4 pin compact tubes as the HF ballast and emergency light units have their own “starter” built in. Lamp data – Compact light tube Figure Type TC-T Compact light tubes 6 limb, 2 pin Ra>80 Economic lifetime 10000 hr TC-TEL Compact light tubes 6 limb, 4 pin Ra>80 Economic lifetime 13000 hr TC-DD/E Compact light tubes 2D, 2 pin Economic lifetime 12000 hr Compact light tubes 2D, 4 pin Economic lifetime 12000 hr ILCOS FSM-I FSM-E FS-I FS-E FS-E ZVEI TC-T TC-TEL Base Wattage (W) Lumen (lm) Luminous eff. (lm/W) GX24d-1 13 900 69 GX24d-2 18 1200 69 G24d-3 26 1800 69 GX24q-2 18 1200 67 GX24q-3 26 1800 69 GX24q-3 32 2400 75 GX24q-4 42 3200 76 GX24q-5 57 4300 75 2G8-1 120 9000 75 GR8 16 1050 GR8 28 2050 GRZ10d 18 1200 GR10q 16 1050 65 GR10q 28 2050 GR10q 38 2850 Colour temp. (K) Item no. 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 2700 3000 4000 3000 4000 77000252 77000256 77000253 77000255 77000254 77000251 77000431 77000429 77001045 77000169 77000173 77000166 77000170 77000174 77000165 77000171 77000319 77000320 77000365 77000366 77000367 77000379 77000368 77000363 77000361 77000362 65 2700 77000139 73 2700 77000178 2700 77000146 2700 77000140 73 2700 77000184 75 2700 77000183 TC-DD TC-DD TC-DD/E Lamp data – Circular tube Figure T16R 200 Type T5 circular tube 16 mm Ra>80 Economic lifetime 16000 hr ILCOS FCH ZVEI T16-R Base 2GX13 Wattage (W) Lumen (lm) 22 1800 40 3200 55 4200 Luminous eff. (lm/W) Colour temp. (K) Item no. 2700 3000 4000 2700 3000 4000 2700 3000 4000 77001000 77001001 77001003 77001005 77001007 77001009 77001011 77001013 77001015 Technical Information Lamp Data - Metal halide Metal halide Metal halide lights produce light by starting an electrical discharge in argon gas between primary and secondary electrodes. This causes ionisation in the discharge tube so the discharge between the electrodes starts. This requires a high starting voltage. For this reason an external starter is used that gives start pulses of 1.5 – 4 kV. It can take up to 10 min. before the light has reached full light flux. Ceramic versions give more stable colour temperatures and color rendering throughout their lifetime. Lamp data – Metal halide Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm)* 35 HITCRI HITDE HITDE HME Miniature Single ended Ceramic MT HIT-CRI G12 HIT-TC-CRI PGJ5 70 150 Double ended Ceramic MD HIT-DECRI Double ended Quartz MD HIT-DE Tube formed Ceramic MT HIT-CRI Tube formed Quartz MT HIT E40 Elliptical formed Diffuse Ceramic** ME ME HIE-CRI HIE-CRI E27 E27 Elliptical formed Diffuse Quartz ME HIE 20 70 RX7s 150 70 150 250 70 150 250 400** 400* 400* 1000 1000 2000 2000 2000 70 150 100 100 150 150 400* 400** RX7s Fc2 E27 E40 E27 E40 3600 7300 6800 13000 14500 1650 6800 6500 14500 14400 5700 12000 20000 7000 14500 20000 34000 42000 35000 8500 110000 180000 240000 210000 6700 13700 7900 7700 11600 11500 34000 26000 (Ra) Colour rendering Colour temp. (K) Item no. 80+ 80+ 90+ 80+ 90+ 85 80+ 90+ 80+ 90+ 80+ 80+ 80+ 80+ 80+ 90 60+ 65+ 90 90 65 90 65 65 80+ 90 80 80 70 80+ 90 90 3000 3000 4200 3000 4200 3000 3000 4200 3000 4200 4000 4000 4200 3000 3000 5200 4000 3500 5200 7250 3500 7250 4400 3800 3000 3000 2900 4000 2900 4000 5300 5500 77000310 77000264 77000314 77000265 77000309 77001196 77000266 77000312 77000267 77000308 77000182 77000181 77000112 77000106 77001039 77000148 77001047 77001047 77000110 77000118 77000126 77000115 77000119 77001204 77000106 77000108 77000023 77001064 77001060 77001042 77000127 77000127 * Can be used with both Sodium (HS) and Metal Halide (HI) ballast. Lumen values are shown Sodium values. ** With Metal Halide ballast. *** Can be used in open luminaires. Figure Type ILCOS ZVEI Base Wattage (W) Beam angle 35 HIPAR30 PAR 30 MR HIPAR 30 HIPAR 51 HIPAR 51 E27 70 20 20 GX10 10 30 10 40 25 40 Light strength (cd) 37000 7000 55000 10000 4000 1700 Colour temp. (K) Item no. 3000 3000 3000 3000 2910 2910 41886 41887 41621 41620 403141 403140 Supplier definitions – Metal Halide Figure ILCOS ZVEI Base HITCRI HITDE MT HIT G12 MD HITDE RX7s MT HIT E40 ME HIE HME Fc2 E27 E40 Wattage (W) 35 70 150 70 150 250 150 250 400¹ 70 100 150 250 400¹ GE Osram* Philips** CMH 35/T CMH 70 T ARC 150 CMH 70 TD ARC 150 ARC 250 HCI-T 35 HCI-T 70 HCI-T 150 HCI-TS 70 HCI-TS HQI-TS 250 HCI-TT HQI-T 250 HQI-T 400 HQI-E 70 HQI-E 100 HQI-E 150 HQI-E 250 HQI-E 400 CDM-T 35 CDM-T 70 CDM-T 150 CDM-TD 70 CDM-TD 150 MHN-TD 250 CDO-TT HPI-T 250 HPI-T plus 400 CDO-ET 70 CDO-ET 100 ARC 250/T ARC 400/T MXR 100 ARC 250/D ARC 400/D HPI-E 250 HPI-E 400 Iwasaki Sylvania MHT 70 HSI-T 70 CMI-T 150 HSI-TD 70 HSI-TD 150 HSI-TD 250 MT 150 MT 250 MT 400 MT 70 MT 150 MT 250 MT 400 HSI-T 250 HSI-T 400 HSI-MP HSI-MP 100 HSI-S 400 HSI-S 400 *Osram definition with Ceramic burner = HCI with Quartz burner= HQI. ** Philips definition with ceramic burner = CD, with Quartz burner = HPI. 201 Technical Information Lamp Data - High intensity sodium High intensity sodium High intensity sodium lamps do not require secondary electrodes. The Xenon gas is ionised with the help of an external starting ignitor that also starts the discharge of sodium vapour. Beyond this starting the operation is as with metal halide lamps. Lamp data – High intensity sodium Figure Type ILCOS ZVEI Base Wattage (W) E27 HST Tube formed Standard Ra=25 Clear ST HST E40 E27 HST HIT-DE Tube formed Long life High Output Ra=25 Clear ST HST E40 Tube formed Double ended SD HST-DE Rx7s E27 HSE HSE Elliptical formed Standard Ra=25 Diffuse Elliptical formed Long life High Output Ra=25 Diffuse CityLight Ra>50 SE HSE E40 E27 SE HSE E40 Lumen (lm) Luminous eff. (lm/W) Colour temp. (K) Item no. 70 5900 84 2000 77001017 150 14500 97 2000 77001019 250 27000 108 2000 77001021 400 48000 120 2000 77001023 1000 130000 130 2000 77000206 1000 130000 130 2000 77001205 50 4400 88 2000 77000212 70 6500 93 2000 77000213 100 10000 100 2000 77000214 150 17500 117 2000 77000215 250 33000 132 2000 77000216 400 55500 139 2000 77000378 600 90000 150 2000 77000377 70 6800 96 2000 77001070 150 15000 100 2000 77001069 50 3500 70 2000 77001027 70 5600 80 2000 77001029 150 14000 93 2000 77001031 250 25000 100 2000 77001033 400 47000 117 2000 77001035 1000 120000 120 2000 77000116 50 3500 70 2000 77000003 70 5600 80 2000 77000001 100 9500 95 2000 77000226 150 17000 113 2000 77000227 250 32000 128 2000 77000228 400 54000 135 2000 77000225 STM HST E27 80 5600 70 3000 77001037 SEM HSE PG12-3 80 6000 75 3000 77001036 Supplier definitions – Sodium lamps Figure ILCOS ZVEI Base E27 HST ST HST E40 E27 HSE SE 202 HSE E40 Wattage (W) 70 100 150 250 400 1000 50 70 100 150 250 400 1000 GE Osram Philips Iwasaki LU70/90/T LU 100/..T LU150/..T LU250./T LU400./T LU1000/T LU50/90/D LU70/90/D LU 100/..D LU150/..D LU250/..D LU400/..D LU1000/.D NAV T 70 NAV T 100 NAV T 150 NAV T 250 NAV T 400 NAV T 1000 NAV E 50 NAV E 70 NAV E 100 NAV E 150 NAV E 250 NAV E 400 NAV E 1000 SON-T 70 SON-T 100 SON-T 150 SON-T 250 SON-T 400 SON-T 1000 SON-E 50 SON-E 70 SON-E 100 SON-E 250 SON-E 250 SON-E 400 SON-E 1000 NHT 100 NHT 150 NHT 250 NHT 400 NHT 1000 NH 50 NH 70./HV/. NH 100 F NH 150.. NH 250.. NH 400.. NH 1000 Sylvania SHP-T 70 SHP-T 100 SHP-T 150 SHP-T 250 SHP-T 400 SHP-T 1000 SHP-S 50 SHP-S 70 SHP-S 100 SHP-S 150 SHP-S 250 SHP 400 Technical Information Lamp Data - Incandescent halogen lamp Incandescent halogen lamp From a light technical point of view halogen lamps function in the same way as normal incandescent lamps. The difference lies in the fact that a halogen is added to prevent the vaporised tungsten from settling on the bulb and blackening it, but instead returns to the electrode. Since the problem of blackening is eliminated, smaller glass bulbs can be used, which are also stronger. This means that higher intensity in the lamp is possible. This raised pressure produces less vaporisation of the filament and so an even higher temperature The result is a significantly higher luminous efficacy compared to conventional incandescent lamps. Lamp data – Low voltage reflector lamp Figure Type ILCOS ZVEI Base QRCBC Cold light lamp with front glass 4000hr QRCBC QRCBC Miniature 4000hr Aluminised Reflector With front glass 3000hr HRGI HRGI HRGI QR-CBC QR-CBC QR-CBC GU5,3 51mm GU4 35mm GU5,3 51mm Wattage (W) Beam angle Intensity (cd) Colour temp. (K) Item no. 20 10 5000 2900 77000030 20 36 780 2900 77000029 20 60 350 2900 77001043 35 10 8000 3000 77000033 35 24 3100 3000 77000032 35 36 1500 3000 77000031 35 60 700 3000 77001041 50 10 1200 3000 77000037 50 24 4400 3000 77000036 50 36 2200 3000 77000035 50 60 11000 3000 77000034 20 10 4500 2900 77001034 20 36 700 2900 77001032 35 10 8000 2900 77001030 35 36 1350 2900 77001028 20 10 3000 2900 77000460 20 36 480 2900 77000461 35 10 6000 2900 77001050 35 36 1000 3000 77000464 50 36 1450 3000 77000459 Lamp data – 230V reflector lamp Figure LEDspot GU10 LEDspot GU10_2 Base Wattage (W) Beam angle Intensity (cd) Colour temp. (K) Item no. LED spot light 40 000h GU10 8 25 1900 3000 77001214 LED spot light 40 000h GU10 8 40 950 3000 77001217 CFL spot light 15 000h GU10 7 45 70 2700 3800639 CFL spot light 15 000h GU10 9 45 110 2700 3800640 CFL spot light 15 000h GU10 11 45 125 2700 3800672 Type ILCOS ZVEI Lamp data – Low voltage halogen burner Figure QT9 QT12 Type 2 pin burner UV blocked 2 pin burner UV blocked ILCOS HSG HSG ZVEI QT9 QT12 Base G4 GY6,35 Wattage (W) Lumen (lm) Luminous eff. (lm/W) Colour temp. (K) Item no. 5 60 12 2900 77000356 10 130 13 2900 77000186 20 300 15 3000 77000199 20 300 15 2900 77000196 35 600 17 3000 77000194 50 910 18 3000 77000191 75 1450 19 3000 77000189 203 Technical Information Lamp Data - Incandescent halogen lamp Incandescent halogen lamps Incandescent halogen lamps work in exactly the same way as ordinary incandescent lamps. The difference lies in the fact that a halogen is added, which prevents the vaporised tungsten from settling on the bulb and blackening it, but instead returns to the electrode. Since the problem of blackening is eliminated, smaller glass bulbs can be used which are stronger. This means that pressure is raised in the lamp. Increased pressure produces less vaporisation of the filament and so an even higher temperature is possible. The result is a significantly higher luminous efficacy compared to conventional incandescent lamps. Lamp data – 230V halogen PAR lamp Figure QPAR16 Type ILCOS ZVEI Base Wattage (W) Beam angle Intensity (cd) Colour temp. (K) Item no. Halo PAR16 CB HAG QPAR 16 GZ10 50 40 750 3000 77001026 GU10 50 40 800 3000 77001024 Halo PAR16 Al QPAR20 QPAR20 Halo PAR 20 Cool Beam HAG Halo PAR 20 Alu reflektor HAG Halo PAR 30 Cool Beam HAG Halo PAR30 Alu reflektor HAG QPAR 20 QPAR 20 QPAR 30 QPAR 30 E27 E27 E27 E27 50 10 3200 3000 77001022 50 30 1100 3000 77001020 50 10 3000 3000 77000425 50 30 1000 3000 77000426 75 10 7500 3000 77001018 75 30 2400 3000 77001016 75 10 6900 3000 77000142 75 30 2200 3000 77000143 Lamp data – 230V halogen tube Figure Type ILCOS ZVEI Base HIT-DE Halogen tube-double ended 204 HDG QPAR 16 R7s Wattage (W) Length (mm) Lumen (lm) Colour temp. (K) Item no. 100 74,9 1600 3000 77000411 150 74,9 2500 3000 77000413 200 114,2 3200 3000 77000416 300 114,2 5000 3000 77000414 500 114,2 9500 3000 77000054