Lamp Data

advertisement
Technical Information
Lamp Data - Light tubes
Light tubes
Light tubes produce light when a starter generates an electrical pulse, which starts
a discharge of gas in the tube. This discharge generates ultraviolet light that is
transformed into visible light when it meets the fluorescent coating (light powder) in
the tubes glass wall.
Different light powders dictate the spectral characteristics. A current through the
tube limits/increases the discharge process and so defines the luminous efficacy.
Ljuskälledata – Lysrör
Figure
Type
T5, Tube
Ra>80
Economic lifetime
19000 hr
ILCOS
FDH
ZVEI
T16
Base
G5
T5, Tube for cold
surroundings
Ra>80
Economic lifetime
19000 hr
T5, ”longlife” tube
Ra>80
Economic lifetime
48000 hr
T5, Tube
ECO
21 000 hr
T8, Tube
Ra>80
Economic lifetime
17000 hr (HF)
12000 hr (F)
Miniature tube
Economic lifetime
8000 hr
FDH
FD
FD
T16
T26
T16
G5
G13
G5
Wattage (W) Lumen(lm)*
14
1200
96
21
1900
100
28
2600
104
35
3300
104
49
4300
100
24
1750
83
39
3100
90
54
4450
93
80
6150
80
54
4850
93
80
6800
88
28
2600
104
49
4300
100
54
4450
93
80
6150
88
13
1150
91
20
1650
83
25
2600
103
32
3100
98
45
4100
92
50
4450
92
73
6300
84
15
1000
67
18
1350
75
30
2450
82
36
3350
93
58
5200
90
8
400
50
* Lumen values for T5 at 25ºC. Maximum luminance value is at 35ºC and is 10 - 14% higher.
**Luminous efficacy is at maximum lumen values.
198
Luminous eff.
(lm/W)**
Colour temp. (K)
Item. no.
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
3000
4000
3000
4000
3000
4000
2700
4000
77000336
77000335
77000337
77000338
77000339
77000340
77000342
77000343
77000344
77000346
77000347
77000348
77000391
77000390
77000393
77000351
77000381
77000384
77000385
77000398
77000388
77000395
77000396
3000
77009010
4000
77009009
3000
77009014
4000
77009015
3000
4000
3000
4000
3000
4000
3000
4000
3000
4000
3000
3000
4000
3000
4000
3000
4000
3000
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
77000800
77000805
77000804
77000812
77000813
77000810
77000811
77000809
77000323
77000403
77000400
77000331
77000407
77000333
77000408
77000332
77000409
77000354
77000355
77000417
77000079
77000080
77000081
77000274
77000275
77000276
77000233
77000324
77000322
77000277
77000278
77000279
77000280
77000281
77000282
77000329
3000
77000298
4000
77000299
Technical Information
Lamp Data - Compact light tubes
Compact light tubes
A compact light tube is in reality just an ordinary tube that has been bent around
on itself so you only need one lamp per fitting. There are two principle types. One
has built-in starter (2 pin) and the other does not (4 pin). Note that for HF ballast
or integrated emergency lighting you should always use 4 pin compact tubes as
the HF ballast and emergency light units have their own ”starter” built in.
Lamp data – Compact light tubes
TC-SEL
TC-S
Figure
Type
Compact light tubes
2 limb short
2 pin
Ra>80
Economic lifetime
10000 hr
Compact light tubes
2 limb short
4 pin
Ra>80
Economic lifetime
13000 hr
TC-L
Compact light tubes
2 limb long
Ra>80
4 pin
Economic lifetime
20000 hr (HF)
15000 hr (F)
ILCOS
FSD-I
FSD-E
FSD-E
TC-R
TC-DEL
TC-D
FSDH-L
Compact light tubes
4 limb, 2 pin
Ra>80
Economic lifetime
10000 hr
Compact light tubes
4 limb, 4 pin
Ra>80
Economic lifetime
13000 hr
Compact light tubes
6 limb, 4 pin
Ra>80
Economic lifetime
13000 hr
ZVEI
TC-S
TC-SEL
TC-L
TC-L
Wattage
(W)
Lumen (lm)
Luminous eff.
(lm/W)
7
400
57
9
600
67
11
900
82
7
400
57
9
600
67
11
900
82
18
1250
69
24
1800
75
28
2700
96
36
2900
81
40
3500
87
55
4850
88
80
6500
81
10
600
60
13
900
69
G24d-2
18
1200
67
G24d-3
26
1800
69
10
600
60
13
900
69
G24q-2
18
1200
67
G24q-3
26
1800
69
14
1050
74
Base
G23
2G7
2G11
2G11
G24d-1
FSQ-I
TC-D
G24q-1
FSQ-E
TC-DEL
TC-R
GR14q
17
1250
74
Colour temp.
(lm/W)
Item no.
2700
3000
3000
4000
2700
3000
2700
4000
2700
4000
3000
4000
2700
3000
4000
2700
3000
4000
3000
4000
2700
3000
4000
3000
4000
3000
4000
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
3000
77000301
77000318
77000317
77000286
77000291
77000316
77000159
77001040
77000160
77000294
77000406
77000295
77000122
77000056
77000120
77000123
77000121
77000058
25103257
25103258
77000124
77000084
77000086
77000095
77000096
77000136
77000137
25103396
25103397
77000015
77000016
77000017
77000022
77000019
77000026
77000009
77000010
77000011
77000221
77000219
77000222
77000097
77000018
77000098
77000099
77000002
77000100
77000012
77000013
77000014
77000220
77000217
77000218
77001208
4000
77001209
3000
77001210
4000
77001211
199
Technical Information
Lamp Data - Compact light tubes
Compact light tubes
A compact light tube is in reality just an
ordinary tube that has been bent around on itself so you only need one lamp per
fitting. There are two principle types. One has built-in starter (2 pin) and the other
does not (4 pin). Note that for HF ballast or integrated emergency lighting you
should always use 4 pin compact tubes as the HF ballast and emergency light
units have their own “starter” built in.
Lamp data – Compact light tube
Figure
Type
TC-T
Compact light tubes
6 limb, 2 pin
Ra>80
Economic lifetime
10000 hr
TC-TEL
Compact light tubes
6 limb, 4 pin
Ra>80
Economic lifetime
13000 hr
TC-DD/E
Compact light tubes
2D, 2 pin
Economic lifetime
12000 hr
Compact light tubes
2D, 4 pin
Economic lifetime
12000 hr
ILCOS
FSM-I
FSM-E
FS-I
FS-E
FS-E
ZVEI
TC-T
TC-TEL
Base
Wattage (W)
Lumen (lm)
Luminous eff.
(lm/W)
GX24d-1
13
900
69
GX24d-2
18
1200
69
G24d-3
26
1800
69
GX24q-2
18
1200
67
GX24q-3
26
1800
69
GX24q-3
32
2400
75
GX24q-4
42
3200
76
GX24q-5
57
4300
75
2G8-1
120
9000
75
GR8
16
1050
GR8
28
2050
GRZ10d
18
1200
GR10q
16
1050
65
GR10q
28
2050
GR10q
38
2850
Colour temp. (K)
Item no.
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
2700
3000
4000
3000
4000
77000252
77000256
77000253
77000255
77000254
77000251
77000431
77000429
77001045
77000169
77000173
77000166
77000170
77000174
77000165
77000171
77000319
77000320
77000365
77000366
77000367
77000379
77000368
77000363
77000361
77000362
65
2700
77000139
73
2700
77000178
2700
77000146
2700
77000140
73
2700
77000184
75
2700
77000183
TC-DD
TC-DD
TC-DD/E
Lamp data – Circular tube
Figure
T16R
200
Type
T5 circular tube
16 mm
Ra>80
Economic lifetime
16000 hr
ILCOS
FCH
ZVEI
T16-R
Base
2GX13
Wattage (W)
Lumen (lm)
22
1800
40
3200
55
4200
Luminous eff.
(lm/W)
Colour temp. (K)
Item no.
2700
3000
4000
2700
3000
4000
2700
3000
4000
77001000
77001001
77001003
77001005
77001007
77001009
77001011
77001013
77001015
Technical Information
Lamp Data - Metal halide
Metal halide
Metal halide lights produce light by starting an electrical discharge in argon
gas between primary and secondary electrodes. This causes ionisation in the
discharge tube so the discharge between the electrodes starts. This requires a
high starting voltage. For this reason an external starter is used that gives start
pulses of 1.5 – 4 kV. It can take up to 10 min. before the light has reached full light
flux. Ceramic versions give more stable colour temperatures and color rendering
throughout their lifetime.
Lamp data – Metal halide
Figure
Type
ILCOS
ZVEI
Base
Wattage (W) Lumen (lm)*
35
HITCRI
HITDE
HITDE
HME
Miniature
Single ended
Ceramic
MT
HIT-CRI
G12
HIT-TC-CRI
PGJ5
70
150
Double ended
Ceramic
MD
HIT-DECRI
Double ended
Quartz
MD
HIT-DE
Tube formed
Ceramic
MT
HIT-CRI
Tube formed
Quartz
MT
HIT
E40
Elliptical formed
Diffuse Ceramic**
ME
ME
HIE-CRI
HIE-CRI
E27
E27
Elliptical formed
Diffuse Quartz
ME
HIE
20
70
RX7s
150
70
150
250
70
150
250
400**
400*
400*
1000
1000
2000
2000
2000
70
150
100
100
150
150
400*
400**
RX7s
Fc2
E27
E40
E27
E40
3600
7300
6800
13000
14500
1650
6800
6500
14500
14400
5700
12000
20000
7000
14500
20000
34000
42000
35000
8500
110000
180000
240000
210000
6700
13700
7900
7700
11600
11500
34000
26000
(Ra) Colour
rendering
Colour temp. (K)
Item no.
80+
80+
90+
80+
90+
85
80+
90+
80+
90+
80+
80+
80+
80+
80+
90
60+
65+
90
90
65
90
65
65
80+
90
80
80
70
80+
90
90
3000
3000
4200
3000
4200
3000
3000
4200
3000
4200
4000
4000
4200
3000
3000
5200
4000
3500
5200
7250
3500
7250
4400
3800
3000
3000
2900
4000
2900
4000
5300
5500
77000310
77000264
77000314
77000265
77000309
77001196
77000266
77000312
77000267
77000308
77000182
77000181
77000112
77000106
77001039
77000148
77001047
77001047
77000110
77000118
77000126
77000115
77000119
77001204
77000106
77000108
77000023
77001064
77001060
77001042
77000127
77000127
* Can be used with both Sodium (HS) and Metal Halide (HI) ballast. Lumen values are shown Sodium values. ** With Metal Halide ballast. *** Can be used in open luminaires.
Figure
Type
ILCOS
ZVEI
Base
Wattage (W) Beam angle
35
HIPAR30
PAR 30
MR
HIPAR 30
HIPAR 51
HIPAR 51
E27
70
20
20
GX10
10
30
10
40
25
40
Light strength
(cd)
37000
7000
55000
10000
4000
1700
Colour temp. (K)
Item no.
3000
3000
3000
3000
2910
2910
41886
41887
41621
41620
403141
403140
Supplier definitions – Metal Halide
Figure
ILCOS
ZVEI
Base
HITCRI
HITDE
MT
HIT
G12
MD
HITDE
RX7s
MT
HIT
E40
ME
HIE
HME
Fc2
E27
E40
Wattage
(W)
35
70
150
70
150
250
150
250
400¹
70
100
150
250
400¹
GE
Osram*
Philips**
CMH 35/T
CMH 70 T
ARC 150
CMH 70 TD
ARC 150
ARC 250
HCI-T 35
HCI-T 70
HCI-T 150
HCI-TS 70
HCI-TS
HQI-TS 250
HCI-TT
HQI-T 250
HQI-T 400
HQI-E 70
HQI-E 100
HQI-E 150
HQI-E 250
HQI-E 400
CDM-T 35
CDM-T 70
CDM-T 150
CDM-TD 70
CDM-TD 150
MHN-TD 250
CDO-TT
HPI-T 250
HPI-T plus 400
CDO-ET 70
CDO-ET 100
ARC 250/T
ARC 400/T
MXR 100
ARC 250/D
ARC 400/D
HPI-E 250
HPI-E 400
Iwasaki
Sylvania
MHT 70
HSI-T 70
CMI-T 150
HSI-TD 70
HSI-TD 150
HSI-TD 250
MT 150
MT 250
MT 400
MT 70
MT 150
MT 250
MT 400
HSI-T 250
HSI-T 400
HSI-MP
HSI-MP 100
HSI-S 400
HSI-S 400
*Osram definition with Ceramic burner = HCI with Quartz burner= HQI. ** Philips definition with ceramic burner = CD, with Quartz burner = HPI.
201
Technical Information
Lamp Data - High intensity sodium
High intensity sodium
High intensity sodium lamps do not require secondary electrodes. The Xenon gas
is ionised with the help of an external starting ignitor that also starts the discharge
of sodium vapour. Beyond this starting the operation is as with metal halide lamps.
Lamp data – High intensity sodium
Figure
Type
ILCOS
ZVEI
Base
Wattage (W)
E27
HST
Tube formed
Standard
Ra=25
Clear
ST
HST
E40
E27
HST
HIT-DE
Tube formed
Long life
High Output
Ra=25
Clear
ST
HST
E40
Tube formed
Double ended
SD
HST-DE
Rx7s
E27
HSE
HSE
Elliptical formed
Standard
Ra=25
Diffuse
Elliptical formed
Long life
High Output
Ra=25
Diffuse
CityLight
Ra>50
SE
HSE
E40
E27
SE
HSE
E40
Lumen (lm)
Luminous eff.
(lm/W)
Colour temp.
(K)
Item no.
70
5900
84
2000
77001017
150
14500
97
2000
77001019
250
27000
108
2000
77001021
400
48000
120
2000
77001023
1000
130000
130
2000
77000206
1000
130000
130
2000
77001205
50
4400
88
2000
77000212
70
6500
93
2000
77000213
100
10000
100
2000
77000214
150
17500
117
2000
77000215
250
33000
132
2000
77000216
400
55500
139
2000
77000378
600
90000
150
2000
77000377
70
6800
96
2000
77001070
150
15000
100
2000
77001069
50
3500
70
2000
77001027
70
5600
80
2000
77001029
150
14000
93
2000
77001031
250
25000
100
2000
77001033
400
47000
117
2000
77001035
1000
120000
120
2000
77000116
50
3500
70
2000
77000003
70
5600
80
2000
77000001
100
9500
95
2000
77000226
150
17000
113
2000
77000227
250
32000
128
2000
77000228
400
54000
135
2000
77000225
STM
HST
E27
80
5600
70
3000
77001037
SEM
HSE
PG12-3
80
6000
75
3000
77001036
Supplier definitions – Sodium lamps
Figure
ILCOS
ZVEI
Base
E27
HST
ST
HST
E40
E27
HSE
SE
202
HSE
E40
Wattage
(W)
70
100
150
250
400
1000
50
70
100
150
250
400
1000
GE
Osram
Philips
Iwasaki
LU70/90/T
LU 100/..T
LU150/..T
LU250./T
LU400./T
LU1000/T
LU50/90/D
LU70/90/D
LU 100/..D
LU150/..D
LU250/..D
LU400/..D
LU1000/.D
NAV T 70
NAV T 100
NAV T 150
NAV T 250
NAV T 400
NAV T 1000
NAV E 50
NAV E 70
NAV E 100
NAV E 150
NAV E 250
NAV E 400
NAV E 1000
SON-T 70
SON-T 100
SON-T 150
SON-T 250
SON-T 400
SON-T 1000
SON-E 50
SON-E 70
SON-E 100
SON-E 250
SON-E 250
SON-E 400
SON-E 1000
NHT 100
NHT 150
NHT 250
NHT 400
NHT 1000
NH 50
NH 70./HV/.
NH 100 F
NH 150..
NH 250..
NH 400..
NH 1000
Sylvania
SHP-T 70
SHP-T 100
SHP-T 150
SHP-T 250
SHP-T 400
SHP-T 1000
SHP-S 50
SHP-S 70
SHP-S 100
SHP-S 150
SHP-S 250
SHP 400
Technical Information
Lamp Data - Incandescent halogen lamp
Incandescent halogen lamp
From a light technical point of view halogen lamps function in the same way as
normal incandescent lamps. The difference lies in the fact that a halogen is added
to prevent the vaporised tungsten from settling on the bulb and blackening it, but
instead returns to the electrode. Since the problem of blackening is eliminated,
smaller glass bulbs can be used, which are also stronger. This means that higher
intensity in the lamp is possible. This raised pressure produces less vaporisation of
the filament and so an even higher temperature The result is a significantly higher
luminous efficacy compared to conventional incandescent lamps.
Lamp data – Low voltage reflector lamp
Figure
Type
ILCOS
ZVEI
Base
QRCBC
Cold light lamp
with front glass
4000hr
QRCBC
QRCBC
Miniature
4000hr
Aluminised
Reflector
With front glass
3000hr
HRGI
HRGI
HRGI
QR-CBC
QR-CBC
QR-CBC
GU5,3
51mm
GU4
35mm
GU5,3
51mm
Wattage
(W)
Beam angle
Intensity (cd)
Colour temp. (K)
Item no.
20
10
5000
2900
77000030
20
36
780
2900
77000029
20
60
350
2900
77001043
35
10
8000
3000
77000033
35
24
3100
3000
77000032
35
36
1500
3000
77000031
35
60
700
3000
77001041
50
10
1200
3000
77000037
50
24
4400
3000
77000036
50
36
2200
3000
77000035
50
60
11000
3000
77000034
20
10
4500
2900
77001034
20
36
700
2900
77001032
35
10
8000
2900
77001030
35
36
1350
2900
77001028
20
10
3000
2900
77000460
20
36
480
2900
77000461
35
10
6000
2900
77001050
35
36
1000
3000
77000464
50
36
1450
3000
77000459
Lamp data – 230V reflector lamp
Figure
LEDspot GU10
LEDspot GU10_2
Base
Wattage
(W)
Beam angle
Intensity (cd)
Colour temp.
(K)
Item no.
LED spot light
40 000h
GU10
8
25
1900
3000
77001214
LED spot light
40 000h
GU10
8
40
950
3000
77001217
CFL spot light
15 000h
GU10
7
45
70
2700
3800639
CFL spot light
15 000h
GU10
9
45
110
2700
3800640
CFL spot light
15 000h
GU10
11
45
125
2700
3800672
Type
ILCOS
ZVEI
Lamp data – Low voltage halogen burner
Figure
QT9
QT12
Type
2 pin burner
UV blocked
2 pin burner
UV blocked
ILCOS
HSG
HSG
ZVEI
QT9
QT12
Base
G4
GY6,35
Wattage (W)
Lumen (lm)
Luminous eff.
(lm/W)
Colour temp. (K)
Item no.
5
60
12
2900
77000356
10
130
13
2900
77000186
20
300
15
3000
77000199
20
300
15
2900
77000196
35
600
17
3000
77000194
50
910
18
3000
77000191
75
1450
19
3000
77000189
203
Technical Information
Lamp Data - Incandescent halogen lamp
Incandescent halogen lamps
Incandescent halogen lamps work in exactly the same way as ordinary
incandescent lamps. The difference lies in the fact that a halogen is added, which
prevents the vaporised tungsten from settling on the bulb and blackening it, but
instead returns to the electrode. Since the problem of blackening is eliminated,
smaller glass bulbs can be used which are stronger. This means that pressure is
raised in the lamp. Increased pressure produces less vaporisation of the filament
and so an even higher temperature is possible. The result is a significantly higher
luminous efficacy compared to conventional incandescent lamps.
Lamp data – 230V halogen PAR lamp
Figure
QPAR16
Type
ILCOS
ZVEI
Base
Wattage (W)
Beam angle
Intensity (cd)
Colour temp. (K)
Item no.
Halo PAR16 CB
HAG
QPAR 16
GZ10
50
40
750
3000
77001026
GU10
50
40
800
3000
77001024
Halo PAR16 Al
QPAR20
QPAR20
Halo PAR 20
Cool Beam
HAG
Halo PAR 20
Alu reflektor
HAG
Halo PAR 30
Cool Beam
HAG
Halo PAR30
Alu reflektor
HAG
QPAR 20
QPAR 20
QPAR 30
QPAR 30
E27
E27
E27
E27
50
10
3200
3000
77001022
50
30
1100
3000
77001020
50
10
3000
3000
77000425
50
30
1000
3000
77000426
75
10
7500
3000
77001018
75
30
2400
3000
77001016
75
10
6900
3000
77000142
75
30
2200
3000
77000143
Lamp data – 230V halogen tube
Figure
Type
ILCOS
ZVEI
Base
HIT-DE
Halogen
tube-double ended
204
HDG
QPAR 16
R7s
Wattage
(W)
Length
(mm)
Lumen (lm)
Colour temp. (K)
Item no.
100
74,9
1600
3000
77000411
150
74,9
2500
3000
77000413
200
114,2
3200
3000
77000416
300
114,2
5000
3000
77000414
500
114,2
9500
3000
77000054
Download