HID Metal Halide Electronic Ballasts Options Please note following OPTIONS when ordering Sage HID ballasts Hot Lamp/Output Short Circuit Protection Option A Thermal switch Auto Reset Retry 20-30 minutes NOTE: High voltage is present at any time unless thermal switch detects high heat and will shut the ballast down or the lamp may re-strike at any time when it cools down to a reasonable temperature and the output short circuit has been alleviated. The 20W HID ballasts are not available in Option B Option B Programmed I. C.Control with reset. Specify “ R ” at the end of Model # for 35W/39W ONLY. All higher wattages are available in this option by design Up to 30 re-strikes for hot lamp, output short circuit condition or recovery from the short circuit on the output before the ballast will shut down. Retry 30 cycles (Each cycle: for 20W,35W, 39W, 50W, 70W, 150W - 1 KHz 4 seconds high voltage, 2 seconds 0 voltage, 4 seconds high voltage, 2 seconds 0 voltage, 4 seconds high voltage, 44 seconds 0 voltage and for 100W - 5KHz instead of 1KHZ). Ensuing re-strikes will require reset at power source. Ballast output will shutdown after 30 minutes if lamp fails. 70W, 100W and 150W are not available in Option A version. External Power supply wiring requirement Specify “ DT ” at the end of Model # When using Sage HID electronic ballast with external power supply for 120V DC at 30mA constant output at 120V-277V AC input for the ballast. “DT” Models will be available with two additional leads. For 50 Watt to 150 Watt ballasts Only Specify “ TT ” at the end of Model # When using Sage HID electronic ballast with internal thermal switch and external power supply for 120V DC at 30mA constant output at 120V-277V AC input for the ballast. __________________________________________________________________________2/02/09___ 1500 Marine Drive, #200 North Vancouver, BC V7P 1T7 TEL: 604-904-9533 FAX: 604-904-9634 EMAIL: sagelighting@shaw.ca www.sagelighting.com HID Metal Halide 1x150W Programmed Pulse Start Hot Lamp/Output Short Circuit protection: Option B see above. Programmed I. C. (PIC) Programmed Pulse Start 120V, 220V-240V or 277V, Electronic Metal Halide ballast for one (1) 150W Philips CDM-TD 150W/830, CDM-T 150W/830, CDM-T 150W/942, CDM-TD 150W/942, GE 150W/830, Osram HQI-TS 150W/NDL, HQI-TS 150W/WDL, HQI-TS 150W/WDL, HCI-T 150W/NDL, HCI-E/P 150W/WDL, Iwaski MT150CE-W/S lamps. ANSI: M102, M142 Technical Specification: Option B UL Listed, CUL Certified Surge Protection: Meets ANSI C62.41 EMI FCC Parts 18, Subparts C, Class A Thermal Protection: CLASS P Rating: Type 1 Outdoor , HL Lamp Current Crest Factor: < 1.6 Sound Rating: Class A Remote Mounting Distance: 50 ft Min. Starting Temp : - 30o C Power Factor: 0.99 Input Frequency: 50/60Hz Max. Case Temp: 90o C End of Lamp Life Protection Circuit Lamp Frequency: 170 Hz THD: < 10% Lead Length: 250mm or 9.8 inch Ballast Factor: 1.0 Ballast output will shut down after 30 mins if lamp fails to ignite Case Size: Series CH3U or CH7U For Bottom leads Specify “B” at the end of Model # Due to continuing efforts to offer improved products all specifications are subject to change without prior notice NO. OF LAMPS INPUT VOLTAGE LAMP WATTS INPUT WATTS AVERAGE MAX INPUT CURRENT (A) 3/09/08 Model # Without External Thermal Case CH3U Case CH7U 1 120V 150 167 1.38 NMHO1150 NMHO1150-C7 1 277V 150 165 0.60 NMHT1150 NMHT1150-C7 1 220V 150 164 0.75 NMHE1150 NMHE1150-C7 1 347V 150 166 0.475 NMHC1150 NMHC1150-C7 LIMITED WARRANTY 5 YEAR at maximum case temperature 75 deg C. 3 YEAR at maximum case temperature 90 deg C. Manufacturer warrants to the purchaser: Electronic Ballast will be free from defects in material or workmanship from the date of manufacture conditioned upon proper storage, installation, use, and maintenance and conformance with any recommendations of Manufacturer Lead Length Colour inch cm Black Black 9.8 9.8 25 25 Blue 9.8 25 Red Green 9.8 9.8 25 25 _________________________________________________________________________________ 1500 Marine Drive, #200 North Vancouver, BC V7P 1T7 TEL: 604-904-9533 FAX: 604-904-9634 EMAIL: sagelighting@shaw.ca www.sagelighting.com HID Metal Halide 1x150W Programmed Pulse Start Hot Lamp/Output Short Circuit protection: Option B see above Programmed I. C. for use with External Thermal Device 120V DC@30mA Programmed Pulse Start 120V, 220V-240V or 277V, Electronic Metal Halide ballast for one (1) 150W Philips CDM-TD 150W/830, CDM-T 150W/830, CDM-T 150W/942, CDM-TD 150W/942, GE 150W/830, Osram HQI-TS 150W/NDL, HQI-TS 150W/WDL, HQI-TS 150W/WDL, HCI-T 150W/NDL, HCI-E/P 150W/WDL, Iwaski MT150CEW/S lamps. ANSI: M102, M142 Technical Specification: Option B External Thermal Device 120V DC UL Listed, CUL Certified Surge Protection: Meets ANSI C62.41 EMI FCC Parts 18, Subparts C, Class A Thermal Protection: CLASS P Rating: Type 1 Outdoor, HL Lamp Current Crest Factor: < 1.6 Sound Rating: Class A Remote Mounting Distance: 50 ft Power Factor: 0.99 Min. Starting Temp : - 30o C Max. Case Temp: 90o C Input Frequency: 50/60Hz End of Lamp Life Protection Circuit Lamp Frequency: 170 Hz THD: < 10% Lead Length: 250mm or 9.8 inch Ballast Factor: 1.0 Ballast output will shut down after 30 mins if lamp fails to ignite Case Size: Series CH3U or CH7U For Bottom leads Specify “B” at the end of Model # Due to continuing efforts to offer improved products all specifications are subject to change without prior notice NO. OF LAMPS INPUT VOLTAGE LAMP WATTS INPUT WATTS AVERAGE MAX INPUT CURRENT (A) 1/09/08 Model # External Thermal 120VDC@30mA Case CH3U Case CH7U 1 120V 150 167 1.38 NMHO1150DT NMHO1150DT-C7 1 277V 150 165 0.60 NMHT1150DT NMHT1150DT-C7 1 220V 150 164 0.75 NMHE1150DT NMHE1150DT-C7 1 347V 150 166 0.475 NMHC1150DT NMHC1150DT-C7 LIMITED WARRANTY 5 YEAR at maximum case temperature 75 deg C. 3 YEAR at maximum case temperature 90 deg C. Manufacturer warrants to the purchaser: Electronic Ballast will be free from defects in material or workmanship from the date of manufacture conditioned upon proper storage, installation, use, and maintenance and conformance with any recommendations of Manufacturer ________________________________________________________________________________ 1500 Marine Drive, #200 North Vancouver, BC V7P 1T7 TEL: 604-904-9533 FAX: 604-904-9634 EMAIL: sagelighting@shaw.ca www.sagelighting.com