Please note following OPTIONS when ordering Sage HID ballasts
Hot Lamp/Output Short Circuit Protection
Option A
Thermal switch Auto Reset Retry 20-30 minutes NOTE: High voltage is present at any time unless
thermal switch detects high heat and will shut the ballast down or the lamp may re-strike at any time
when it cools down to a reasonable temperature and the output short circuit has been alleviated.
The 20W HID ballasts are not available in Option B
Option B
Programmed I. C.Control with reset. Specify “ R ” at the end of Model #
for 35W/39W ONLY. All higher wattages are available in this option by design
Up to 30 re-strikes for hot lamp, output short circuit condition or recovery from the short circuit on the
output before the ballast will shut down. Retry 30 cycles (Each cycle: for 20W,35W, 39W, 50W,
70W, 150W - 1 KHz 4 seconds high voltage, 2 seconds 0 voltage, 4 seconds high voltage, 2
seconds 0 voltage, 4 seconds high voltage, 44 seconds 0 voltage and for 100W - 5KHz instead of
1KHZ). Ensuing re-strikes will require reset at power source. Ballast output will shutdown after 30
minutes if lamp fails. 70W, 100W and 150W are not available in Option A version.
External Power supply wiring requirement
Specify “ DT ” at the end of Model # When using Sage HID electronic ballast with external power
supply for 120V DC at 30mA constant output at 120V-277V AC input for the ballast. “DT” Models
will be available with two additional leads.
For 50 Watt to 150 Watt ballasts Only
Specify “ TT ” at the end of Model # When using Sage HID electronic ballast with internal thermal
switch and external power supply for 120V DC at 30mA constant output at 120V-277V AC input for
the ballast.
__________________________________________________________________________2/02/09___
1500 Marine Drive, #200 North Vancouver, BC V7P 1T7
TEL: 604-904-9533 FAX: 604-904-9634
EMAIL: sagelighting@shaw.ca
www.sagelighting.com
HID Metal Halide
1x150W
Programmed Pulse Start
Hot Lamp/Output Short Circuit protection: Option B see above. Programmed I. C. (PIC)
Programmed Pulse Start 120V, 220V-240V or 277V, Electronic Metal Halide ballast for one (1)
150W Philips CDM-TD 150W/830, CDM-T 150W/830, CDM-T 150W/942, CDM-TD 150W/942, GE
150W/830, Osram HQI-TS 150W/NDL, HQI-TS 150W/WDL, HQI-TS 150W/WDL, HCI-T 150W/NDL,
HCI-E/P 150W/WDL, Iwaski MT150CE-W/S lamps. ANSI: M102, M142
Technical Specification: Option B
UL Listed, CUL Certified
Surge Protection:
Meets ANSI C62.41
EMI
FCC Parts 18, Subparts C, Class A
Thermal Protection:
CLASS P
Rating:
Type 1 Outdoor , HL
Lamp Current Crest Factor:
< 1.6
Sound Rating:
Class A
Remote Mounting Distance:
50 ft
Min. Starting Temp : - 30o C
Power Factor:
0.99
Input Frequency:
50/60Hz
Max. Case Temp:
90o C
End of Lamp Life Protection Circuit
Lamp Frequency:
170 Hz
THD:
< 10%
Lead Length:
250mm or 9.8 inch
Ballast Factor:
1.0
Ballast output will shut down after 30 mins if lamp fails to ignite
Case Size: Series CH3U or CH7U
For Bottom leads Specify “B” at the end of Model #
Due to continuing efforts to offer improved products all specifications are subject to change without prior notice
NO. OF
LAMPS
INPUT
VOLTAGE
LAMP
WATTS
INPUT
WATTS
AVERAGE
MAX
INPUT
CURRENT
(A)
3/09/08
Model #
Without External Thermal
Case CH3U
Case CH7U
1
120V
150
167
1.38
NMHO1150
NMHO1150-C7
1
277V
150
165
0.60
NMHT1150
NMHT1150-C7
1
220V
150
164
0.75
NMHE1150
NMHE1150-C7
1
347V
150
166
0.475
NMHC1150
NMHC1150-C7
LIMITED WARRANTY
5 YEAR at maximum case temperature 75 deg C. 3 YEAR at maximum case temperature 90 deg C. Manufacturer warrants to the
purchaser: Electronic Ballast will be free from defects in material or workmanship from the date of manufacture conditioned upon proper
storage, installation, use, and maintenance and conformance with any recommendations of Manufacturer
Lead Length
Colour inch cm
Black
Black
9.8
9.8
25
25
Blue
9.8
25
Red
Green
9.8
9.8
25
25
_________________________________________________________________________________
1500 Marine Drive, #200 North Vancouver, BC V7P 1T7
TEL: 604-904-9533 FAX: 604-904-9634
EMAIL: sagelighting@shaw.ca
www.sagelighting.com
HID Metal Halide 1x150W
Programmed Pulse Start
Hot Lamp/Output Short Circuit protection: Option B see above
Programmed I. C. for use with External Thermal Device 120V DC@30mA
Programmed Pulse Start 120V, 220V-240V or 277V, Electronic Metal Halide ballast for one (1) 150W Philips
CDM-TD 150W/830, CDM-T 150W/830, CDM-T 150W/942, CDM-TD 150W/942, GE 150W/830, Osram HQI-TS
150W/NDL, HQI-TS 150W/WDL, HQI-TS 150W/WDL, HCI-T 150W/NDL, HCI-E/P 150W/WDL, Iwaski MT150CEW/S lamps. ANSI: M102, M142
Technical Specification: Option B External Thermal Device 120V DC
UL Listed, CUL Certified
Surge Protection:
Meets ANSI C62.41
EMI
FCC Parts 18, Subparts C, Class A
Thermal Protection:
CLASS P
Rating:
Type 1 Outdoor, HL
Lamp Current Crest Factor:
< 1.6
Sound Rating:
Class A
Remote Mounting Distance:
50 ft
Power Factor:
0.99
Min. Starting Temp : - 30o C
Max. Case Temp:
90o C
Input Frequency:
50/60Hz
End of Lamp Life Protection Circuit
Lamp Frequency:
170 Hz
THD:
< 10%
Lead Length:
250mm or 9.8 inch
Ballast Factor:
1.0
Ballast output will shut down after 30 mins if lamp fails to ignite
Case Size: Series CH3U or CH7U
For Bottom leads Specify “B” at the end of Model #
Due to continuing efforts to offer improved products all specifications are subject to change without prior notice
NO. OF
LAMPS
INPUT
VOLTAGE
LAMP
WATTS
INPUT
WATTS
AVERAGE
MAX
INPUT
CURRENT
(A)
1/09/08
Model #
External Thermal 120VDC@30mA
Case CH3U
Case CH7U
1
120V
150
167
1.38
NMHO1150DT
NMHO1150DT-C7
1
277V
150
165
0.60
NMHT1150DT
NMHT1150DT-C7
1
220V
150
164
0.75
NMHE1150DT
NMHE1150DT-C7
1
347V
150
166
0.475
NMHC1150DT
NMHC1150DT-C7
LIMITED WARRANTY
5 YEAR at maximum case temperature 75 deg C. 3 YEAR at maximum case temperature 90 deg C. Manufacturer warrants to the
purchaser: Electronic Ballast will be free from defects in material or workmanship from the date of manufacture conditioned upon proper
storage, installation, use, and maintenance and conformance with any recommendations of Manufacturer
________________________________________________________________________________
1500 Marine Drive, #200 North Vancouver, BC V7P 1T7
TEL: 604-904-9533 FAX: 604-904-9634
EMAIL: sagelighting@shaw.ca
www.sagelighting.com