ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO PDL 46-200 Page 1 ISO 9001 Certified Ficha Técnica Single Phase Overhead Distribution Transformers January, 2002 Single Phase Transformers ( ≤ 100 kVA ) ments of ANSI C57.12.28. The multistep process includes an epoxy primer uniformly applied by cationic electrodeposition and a urethane top coat. The following additional features are all standard on self-protected type CSP® units: 16. Primary protective link. 17. Surge arrester. 18. Secondary circuit breaker. 19. Secondary breaker operating handle with emergency overload reset and overload signal light. Construction features Description ABB Distribution Transformers manufactures single-phase, oil type small distribution transformers for pole mounting. These represent an economical option for certain networks. They are suitable for serving residential overhead distribution loads, as well as for lighting, commercial loads, industrial and diversified power applications. ABB’s core design provides Type CSP optimal efficiency and better mechanical, thermal and electrical performance. These transformers are designed for the duties norABB single phase, oil-filled, pole-mounted mally encountered on electric utility power distribution systems.are specifically distribution transformers Options 25 Type S Options andFeatures: accessories Standard 1.Bushings Liftingmounted lugs. on lid or on turrets. 2 or 3 options. Internal HT fuses can be fitted. 2.view Arrester mounting pads. ANSI or DIN bushings. Single or dual ratio. 3.Tap-switch Cover-mounted high voltage porcelain or internal link board. Can be fitted bushing(s) eyebolt terminal with acing hornswith or surge arrestors. (10-100 kVA) or spade terminal. 4.Standard Low voltage insulators are available and type tests Can supplied inreinforced accordance with IETS, IEC in be fiberglass polyester ormaterial ANSI standards. All units have been type and or porcelain (both eyebolt tested according to IEC. spade terminals). Standard features for EATS or ANSI can be 5. Low voltage neutral grounding strap Ratingsprovided. (furnished on 10-50 kVA single HV • 5-833 kVA bushing units). units are supplied • 65 CAlltemperature risewith hot-dip galvanised 6. ANSI support lugs (hanger brackets). tanks including: • 60 hertz standard, 50 hertz optional 7. Cover has 13 mils minimum of - lifting lugs • Low voltages: 120/240, 240/480 and polyester coating providing 15 kV - cover mounted, high voltage porcelain 277 bushing(s) with eyebolt terminal or spade dielectric insulation of tank ground • High voltages: 2400 through 34,400 parts from live parts and increased terminal Volts- fibreglass reinforced polyester or porcelain resistance to corrosion. • Insulation levels: low voltage insulators 8. Self-venting and resealing cover assembly. 9. The core/coil bolt-in pads are 180 Rated Voltage Insulation Basic Impulse apart. Ranges Class Level (kV) Power Technology Products 10.Transformers Embossed low voltageABB leads. 480-600 1.2 3024 - Single Phase 11. Oil filled plug with cover ground strap. 2160-2400 5.0 60 12. Tank ground pad. 4160-4800 8.7 75 13. Laser etched anodized aluminum 7200-12470 15.0 95 nameplate with bar coded serial Optional 125 kV BIL 12000 volts available. number. 13200-14400 18.0 125 14. The paint finish process applies a 19920-22900 25.0 150 durable, corrosion resistant finish to Optional 125 kV BIL 19920 volts available. the product. The finish meets or -34400 34.5 200 exceeds all the performance requiredesigned for servicing residential overhead Ranges distribution loads. They are also suitable 15 kVA to 100loads, kVA with voltages up to a for light commercial industrial maximum of 36 kV. lighting and diversified power applications. These transformers are designed for the Standard features application conditions normally Two types of transformer areencounmanufactured: tered on electric utility power distribution - sealed construction systems. - free breathing construction Tel.: (506) 2251-4100 Fax: (506) 2251-3131 info@elmecsa.com 1. Primary Termination • Cover-mounted high voltage porcelain bushing(s) with spin top terminal. • Side-wall mounted high voltage porcelain bushing(s) with spin top terminal (Standard on all 4800 volts and below). • Primary current limiting backup fuse. 2. Secondary Termination • Low voltage porcelain bushings with NEMA spade terminals (Standard on all units 167 kVA and above). 3. Primary Switching • Externally-operated tap changer. • Externally-operated dual voltage switch or internal terminal board. 4. Overcurrent Protection • Internally-mounted current limiting fuse in series with protective link. 5. Contact the division for voltages and dimensions on 666 through 833 kVA. Optional Accessories 1. High voltage bushings are of two types and are made of wet process porcelain: • Speed wrench operable eyebolt bushing for cover mounting. • Spin-top bushings for either cover or side-wall mount. 2. Tap changers compensate for small voltage variations along the distribution system. The externally-operated tap changer is a single-phase, five-position design for de-energized operation. 3. A dual voltage switch permits use of the same transformer on distribution systems with different system voltages. 4. The CSP® protection package consists of four related components that work together to provide complete selfcontained protection against surge currents, short circuits and overloads: San José, Costa Rica 300m. norte del BCR Plazoleta San Antonio de Desamparados Class Designations 1. Type CSP®, above 5 kV, 10-100 kVA. Class A: Two fully-insulated high voltage bushings, two arresters, two protective links and external breaker handle. Suitable for application on either wye or delta distribution systems. Single-position pole mounting in accordance with latest ANSI standards. CLASS DESIGNATIONS TYPE CSP, HV ABOVE 5 KV, 10-100 KVA 75 - 100 KVA ANSI TYPE ‘B’ LUG 75 - 100 KVA ANSI TYPE ‘B’ LUG Class B-1: Two fully-insulated high voltage bushings, one arrester, two protective links and external breaker handle. Normally applied on solidly grounded systems. Class B-2: One fully-insulated high voltage bushing, one arrester, one protective link and external breaker handle. Suitable only for application on solidly grounded distribution systems. Single-position pole mounting in accordance with latest ANSI standards. Class B-3: Same as class B-2 except with two-position mounting. ABB 2. Type CSP®, 5 kV and below, 10-100 kVA. Similar to Type CSP above 5 KV except: • Sidewall-mounted primary bushings. • Class B-2 and B-3 not available. ABB 1. Type S, above 5 kV, 10-500 kVA. Class A: Two fully-insulated high voltage bushings, suitable for application on either wye or delta distribution systems. Singleposition pole mounting in accordance with the latest ANSI standards. CLASS A CLASS B-3 < 75 KVA CLASS B-2 Class B-2: One fully-insulated high voltage bushing, suitable only for application on solidly grounded distribution systems. Single-position pole mounting in accordance with the latest ANSI standards. 167 KVA ANSI TYPE ‘B’ LUG Class B-3: Same as class B-2 except with two-position mounting. 2. Type S, 5 kV and below, 10-500 kVA. Similar to Type S, above 5 kV, except: • Sidewall-mounted primary bushings. • Only Class A is available. CLASS DESIGNATIONS TYPE S, HV ABOVE 5 KV, 10-500 KVA 75 - 100 KVA ANSI TYPE ‘B’ LUG 75 - 100 KVA ANSI TYPE ‘B’ LUG ABB CLASS A > 100 KVA CLASS A 100 KVA CLASS B-2 100 KVA ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO CLASS B-3 < 75 KVA January, 2002 ISO 9001 Certified Tel.: (506) 2251-4100 Fax: (506) 2251-3131 info@elmecsa.com San José, Costa Rica 300m. norte del BCR Plazoleta San Antonio de Desamparados