MODEL Series 20 Series 20 Series 20 Model SV Model SV VALVES RD5100 RD5200 RD5300 RD5000 RD4100 LVS LVT LVR LS3000 RD2500 FR10-3P RD-100 RD-1900 RD-400 RD-500 RD-200 RD-300 RD-500P RD-1000S RV DRV RD-1800 RD-900 MODEL SS MODEL DS RD-1400 RD-1600 V2 INDEX DESCRIPTION .......................................................................PAGE 20 GPM Stack Type Directional Control Valve ..............................................V3 20 GPM Load Sense Stack Type Direction and Control Valve ....................V13 20 GPM Solenoid Operated Work Section ..................................................V18 12 GPM Stack Type Directional Control Valve ............................................V21 12 GPM Solenoid Operated Work Section ..................................................V32 Stack Valve Assembly Quotation Request Form .........................................V38 30 GPM Single Spool Mono-Block Directional Control Valve......................V39 25 GPM Two Spool Mono-Block Direction Control Valve ............................V39 25 GPM Three Spool Mono-Block Directional Control Valve ......................V39 Solenoid Operated 1, 2, or 3 Spool Mono-Block Valve ...............................V47 15 GPM Single Spool Mono-Block Directional Control Valve......................V48 11 GPM Two Spool Mono-Block Loader Valve ............................................V51 10 GPM Two Spool Mono-Block Loader Valve ...........................................V53 14 GPM Two Spool Mono-Block Loader Valve ...........................................V54 25 GPM Single Spool Log Splitter Control Valve ........................................V56 20 GPM Single Spool Mono-Block Directional Control Valve......................V58 Priority Flow Regulator 15 GPM ..................................................................V60 30 GPM Adjustable Flow Control ................................................................V61 30 GPM Adjustable Flow Control ................................................................V61 30 GPM Priority Divider, Fixed Flow............................................................V63 30 GPM Priority Divider, Adjustable Flow ....................................................V63 30 GPM Proportional Divider, Fixed Ratio...................................................V65 30 GPM Proportional Divider with Reverse Flow ........................................V65 30 GPM Proportional Divider, Adjustable Ratio ...........................................V65 30 GPM Sequence Valve ............................................................................V65 30 GPM Inline Relief Valve..........................................................................V67 30 GPM Double Relief Valve .......................................................................V67 20 GPM Ball/Spring Relief...........................................................................V69 30 GPM Single Selector Valve ....................................................................V69 20 GPM Single Selector Valve ....................................................................V70 40 GPM Double Selector Valve ...................................................................V71 30 GPM Lock Valve, Double Pilot Check ....................................................V72 20 GPM Pilot-Operated Check Valve ..........................................................V72 Design Charts, Hydraulic Formulas, Metric Conversions ............................V73 Valve Quick Reference Guide .....................................................................V74 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 2-07-13-02 Directional Control Valves VALVES SECTIONAL BODY Series “20”” STANDARD FEATURES :RUN6HFWLRQV ([WUD)LQH6SRRO0HWHULQJ 3RZHU%H\RQG&DSDELOLW\ 5HYHUVLEOH+DQGOH /RDG&KHFNVRQ(DFK:RUN3RUW +DUG&KURPH3ODWHG6SRROV $)ORDW6HFWLRQFDQEH,QVWDOOHGLQDQ\/RFDWLRQLQ9DOYH$VVHPEO\ ,QWHUFKDQJHDEOH0RXQWLQJ:LWK2WKHU3RSXODU´µJSP6WDFN9DOYHV 2SWLRQDO:RUN6HFWLRQZLWK3LORW2SHUDWHG&KHFNV SPECIFICATIONS Parallel or Tandem Circuit Foot Mounting Pressure Rating Weight 0D[LPXP2SHUDWLQJ3UHVVXUH ...... SVL ,QOHW&RYHU ........................... $SSUR[OEV 0D[LPXP7DQN3UHVVXUH ................. SVL 2XWOHW&RYHU ..................... $SSUR[OEV :RUN6HFWLRQ ....................... $SSUR[OEV Nominal Flow Rating ...................... 20 gpm 3OHDVH5HIHUWR3UHVVXUH'URS&KDUWV $OORZDEOH3UHVVXUH/RVVWKUX9DOYH 'HWHUPLQHVWKH0D[LPXPÁRZ CATV 3-10-11-01 Maximum Operating Temp ..........180°F Filtration:)RUJHQHUDOSXUSRVHYDOYHV ÁXLGFOHDQOLQHVVVKRXOGPHHWWKH,62 OHYHO)RUH[WHQGHGOLIHRU IRUSLORWRSHUDWHGYDOYHVWKH ÁXLGFOHDQOLQHVVOHYHOLVUHFRPPHQGHG 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V3 ORDERING INFORMATION: The following is a listing of valve sections available from stock on a standard basis. STANDARD SECTIONS AVAILABLE: STANDARD INLET SECTIONS ALL SECTIONS HAVE BOTH TOP AND SIDE INLET AND TANK PORTS PART NO. RELIEF TYPE AND SETTING NO RELIEF 20I2A 20I2C SHIM ADJUSTABLE 1351-1750 PSI, SET AT 1750 PSI @ 10 GPM 20I2D SHIM ADJUSTABLE 1751-2200 PSI, SET AT 2200 PSI @ 10 GPM 20I2E SHIM ADJUSTABLE 2201-3000 PSI, SET AT 2500 PSI @ 10 GPM 20I2G ADJUSTABLE 1351-1750 PSI, SET AT 1750 PSI @ 10 GPM 20I2H ADJUSTABLE 1750-2200 PSI, SET AT 2200 PSI @ 10 GPM 20I2J ADJUSTABLE 2201-3000 PSI, SET AT 2500 PSI @ 10 GPM PORT SIZE #12 SAE ORB #12 SAE ORB #12 SAE ORB #12 SAE ORB #12 SAE ORB #12 SAE ORB #12 SAE ORB STANDARD PARALLEL CIRCUIT WORK SECTIONS ALL WORK SECTIONS HAVE #10 SAE ORB PORTS, LOAD CHECKS, AND STANDARD LEVER HANDLES. MODELS WITH PORT RELIEFS ARE SHIM ADJUSTABLE. PART NO. SPOOL TYPE AND ACTION 20P1AA1AA 3-WAY SINGLE ACTING W/SPRING CENTER 20P1BA1AA 4-WAY DOUBLE ACTING W/SPRING CENTER (WORK PORTS BLOCKED IN NEUTRAL) 20P1BA5AA-S12Q 4-WAY DOUBLE ACTING W/SPRING CENTER, 12VDC SOLENOID OPERATED 20P1BA6AA-S12Q 4-WAY DOUBLE ACTING W/SPRING CENTER, 12VDC SOLENOID OPERATED W/LEVER HANDLE 20P1BB1AA 4-WAY DOUBLE ACTING W/3 POSITION DETENT (WORK PORTS BLOCKED IN NEUTRAL) 20P1CA1AA 4-WAY FREE FLOW MOTOR W/SPRING CENTER (WORK PORTS OPEN TO TANK IN NEUTRAL) 20P1CB1AA 4-WAY FREE FLOW MOTOR W/3 POSITION DETENT (WORK PORTS OPEN TO TANK IN NEUTRAL) 20P1DD1AA 4-WAY 4 POSITION FLOAT W/SPRING CENTER AND FLOAT DETENT 20P1BA1DD 4-WAY DOUBLE ACTING W/SPRING CENTER (WORK PORTS BLOCKED IN NEUTRAL) 20P1DD1DD 4-WAY 4 POSITION FLOAT W/SPRING CENTER AND FLOAT DETENT 20L1CA1 4-WAY 3 POSITION W/SPRING CENTER AND P.O. CHECKS 20LP1JA1AA LOAD SENSE 4-WAY DOUBLE ACTING WITH SPRING CENTER PORT RELIEFS PLUGGED PLUGGED PLUGGED PLUGGED PLUGGED PLUGGED PLUGGED PLUGGED 2200 PSI 2200 PSI NONE PLUGGED STANDARD TANDEM CIRCUIT WORK SECTIONS VALVES PART NO. 20T1BA1AA 20T1BA1DD 20T1CA1AA SPOOL TYPE AND ACTION 4-WAY DOUBLE ACTING W/ SPRING CENTER (WORK PORTS BLOCKED IN NEUTRAL) 4-WAY DOUBLE ACTING W/ SPRING CENTER (WORK PORTS BLOCKED IN NEUTRAL) 4-WAY FREE FLOW MOTOR W/ SPRING CENTER (WORK PORTS OPEN TO TANK IN NEUTRAL) PORT RELIEFS PLUGGED 2200 PSI PLUGGED STANDARD OUTLET SECTIONS ALL SECTIONS HAVE SIDE OUTLET PART NO. EXHAUST OPTION 20E21 OPEN CENTER OUTLET W/ CONVERSION PLUG 20E22 POWER BEYOND OUTLET W/ #10 SAE POWER BEYOND PORT 20E23 CLOSED CENTER OUTLET 20LE21 LOAD SENSE OUTLET WITH #4 LOAD SENSE PORT AND BLEED ORIFICE PORT SIZE #12 SAE ORB #12 SAE ORB #12 SAE ORB #12 SAE ORB TIE-ROD KITS TIE-ROD TORQUE 30-32 ft-lbs PART NO. 660402001 660402002 660402003 660402004 660402005 WORK SECTIONS 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION PART NO. 660402006 660402007 660402008 660402009 660402010 WORK SECTIONS 6 SECTION 7 SECTION 8 SECTION 9 SECTION 10 SECTION PORT RELIEF CARTRIDGES SERIES 20 HARDWARE AND SEAL KITS 660190003 660190004 660190005 660190028 660190001 660190002 660190006 660190007 660190025 660190026 660290004 660290017 660290005 660290006 660585001 660585008 660590030 660585002 660585003 660585004 SPRING CENTER KIT 3 POSITION DETENT KIT FRICTION DETENT KIT SPRING CTR PNEUMATIC ACTUATOR KIT VERTICAL HANDLE, LINK & PINS STD. HANDLE, LINK & PINS COMPLETE VERT. HANDLE KIT COMPLETE STD. HANDLE KIT SEAL RETAINER PLATE HANDLE CLEVIS POWER BEYOND PLUG #10 SAE POWER BEYOND PLUG 3/4” NPTF CLOSED CENTER PLUG OPEN CENTER OUTLET PLUG WORK SECTION SEAL KIT LOCK SECTION SEAL KIT SOLENOID OPERATED SECT SEAL KIT (5.6) INLET SECTION SEAL KIT OUTLET SECTION SEAL KIT SEAL KIT 0-RINGS BETWEEN SECTION ONLY 660585006 660390103 660390107 660290010 660390153 660390157 270006092 660290012 SOLENOID PILOT PASSAGE SEAL KIT 20 WORK SECT COIL & CART ASSY 12VDC/LEADS 20 WORK SECT COIL & CART ASSY 24VDC/LEADS 20 UTIL SECT CONTINUOUS ON PBU CART 20 UTIL SECT PBU COIL & CART ASSY 12VDC/LEADS 20 UTIL SECT PBU COIL & CART ASSY 24VDC/LEADS 20 UTIL SECT PRESSURE REDUCING CART 20 UTIL SECT POWER BEYOND PLUG #10 SAE PORT RELIEF KITS (FOR PRESET CARTRIDGE USE 20 PR-OX PG V16) 660290002 NO RELIEF LOAD CHECK PLUG 660290301 SHIM ADJ. 500 - 1350 PSI 660290303 SHIM ADJ. 1351 - 1750 PSI 660290305 SHIM ADJ. 1751 - 2200 PSI 660290307 SHIM ADJ. 2201 - 3000 PSI 660290401 ADJUSTABLE 500 - 1350 PSI 660290403 ADJUSTABLE 1351 - 1750 PSI 660290405 ADJUSTABLE 1751 - 2200 PSI 660290407 ADJUSTABLE 2201 - 3000 PSI 660290003 ANTI-CAVITATION CARTRIDGE 5(/,()&$575,'*(6$5($/62$9$,/$%/(:,7+67$,1/(6667((/5(/,()635,1*6 V4 INLET RELIEF KITS (FOR PRESET CARTRIDGE USE 20 IR-OX PG V16) 660290001 NO RELIEF PLUG 660290101 SHIM ADJ. 500 - 1350 PSI 660290103 SHIM ADJ. 1351 - 1750 PSI 660290105 SHIM ADJ. 1751 - 2200 PSI 660290107 SHIM ADJ. 2201 - 3000 PSI 660290201 ADJUSTABLE 500 - 1350 PSI 660290203 ADJUSTABLE 1351 - 1750 PSI 660290205 ADJUSTABLE 1751 - 2200 PSI 660290207 ADJUSTABLE 2201 - 3000 PSI RELIEF HARDWARE KITS 660190024 SHIM STYLE TO ADJ STYLE CONVERSION KIT 672000201 .006 SHIM FOR RELIEF 672000202 .010 SHIM FOR RELIEF 672000203 .018 SHIM FOR RELIEF 672000205 .041 SHIM FOR RELIEF 660190043 SHIM ASSORTMENT LOAD SENSE KITS 660290018 LOAD SENSE PLUG W/DRAIN ORIFICE 660290019 LOAD SENSE PLUG W/O DRAIN ORIFICE 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11, 12 & 13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 4-7-13-02 SPECIAL SECTIONS AVAILABLE: Valves other than standard models listed can be made to order. Use order code Matrix below to generate a model number WKDWPHHWV\RXUUHTXLUHPHQWV,I\RXSUHIHUFRQWDFW\RXU6DOHV5HSUHVHQWDWLYHZLWK\RXUVSHFL¿FUHTXLUHPHQWVDQGDPRGHO number will be assigned for you. This model number can then be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. 20XXXXXXX WORK SECTION TYPE PORT RELIEF “B” (LEAVE BLANK FOR 20L) PORT RELIEF “A” (LEAVE BLANK FOR 20L) P-STANDARD PARALLEL T-TANDEM CENTER L-PARALLEL WITH BUILT IN PILOT OPERATED CHECKS** S-SERIES A - NO RELIEF B - SHIM ADJUSTABLE RELIEF 500-1350 PSI SET AT 1350 C - SHIM ADJUSTABLE RELIEF 1351-1750 PSI SET AT 1750 D - SHIM ADJUSTABLE RELIEF 1751-2200 PSI SET AT 2200 E - SHIM ADJUSTABLE RELIEF 2201-3000 PSI SET AT 2500 F - ADJUSTABLE RELIEF 500-1350 PSI SET AT 1350+ G - ADJUSTABLE RELIEF 1351-1750 PSI SET AT 1750+ H - ADJUSTABLE RELIEF 1751-2200 PSI SET AT 2200+ J - ADJUSTABLE RELIEF 2201-3000 PSI SET AT 2500+ K - ANTI-CAVITATION CHECK L - PORT RELIEF/ANTI-CAV SHIM ADJ 500-1350 PSI SET AT 1350 M - PORT RELIEF/ANTI-CAV SHIM ADJ 1351-1750 PSI SET AT 1750 N - PORT RELIEF/ANTI-CAV SHIM ADJ 1751-2200 PSI SET AT 2200 R - PORT RELIEF/ANTI-CAV SHIM ADJ 2201-3000 PSI SET AT 2500 S - PORT RELIEF/ANTI-CAV ADJUSTABLE 500-1350 PSI SET AT 1350+ T - PORT RELIEF/ANTI-CAV ADJUSTABLE 1351-1750 PSI SET AT 1750+ W - PORT RELIEF/ANTI-CAV ADJUSTABLE 1751-2200 PSI SET AT 2200+ Y - PORT RELIEF/ANTI-CAV ADJUSTABLE 2201-3000 PSI SET AT 2500+ PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) 5. 3/8 NPTF (2000 PSI MAX) SPOOL TYPE A - 3 WAY 3 POSITION B - 4 WAY 3 POSITION C - 4 WAY 3 POSITION FREE FLOW MOTOR D - 4 WAY 4 POSITION FLOAT E - 3 WAY 3 POSITION FREE FLOW MOTOR N - 4 WAY 3 POSITION SERIES P - 4 WAY 3 POSITION SERIES MOTOR SPOOL ACTIONS A - SPRING CENTER TO NEUTRAL B - 3 POSITION DETENT C - FRICTION DETENT D - FLOAT DETENT E - SPRING CENTER PNEUMATIC ACTUATOR F - 2 POSITION DETENT NEUTRAL & OUT (NO IN POSITION) H - HYDRAULIC ACTUATOR (USE HANDLE OPTION 7) J - SPRING CENTER W/ MICROSWITCH (SWITCHES ON IN OR OUT)*** K - SPRING CENTER W/ MICROSWITCH (SWTCHES ON SPOOL IN ONLY )*** M - SPRING CENTER DETENT IN N - SPRING CENTER DETENT OUT P - 2 POSITION DETENT NEUTRAL & IN (NO OUT POSITION) + ADJUSTABLE PORT RELIEF CARTRIDGES CANNOT BE USED ON THE “A” PORT END OF WORK SECTION WHEN THE STANDARD LEVER HANDLE IS USED BECAUSE OF INTERFERENCE FOR WORK PORT RELIEF SETTING OTHER THAN STANDARD 20P1BA1DH-18-20 “B” PORT RELIEF PRESSURE IN HUNDREDS EXAMPLE: 20=2000 PSI “A” PORT RELIEF PRESSURE IN HUNDREDS EXAMPLE: 18=1800 PSI VALVES WORK SECTION HANDLE OPTIONS 1 - STANDARD LEVER HANDLE* 2 - LESS HANDLE ONLY 3 - LESS COMPLETE HANDLE 4 - VERTICAL LEVER HANDLE* 7 - BLANK FOR OPTIONAL JOYSTICK HANDLE INLET SECTION * LEVERS ARE COATED WITH BLACK RUBBER ** L WORK SECTION REQUIRES SPOOL TYPE C & PORT RELIEFS NOT AVAILABLE *** MICROSWITCH INCLUDED. 20IXX - XXXX INLET TYPE OUTLET SECTION OUTLET TYPE I - STANDARD INLET E - STANDARD OUTLET PORT SIZE PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #12 SAE (1 1/16-12 THREAD) 3. 3/4 NPTF (2000 PSI MAX) 1. #10 SAE (7/8-14 THREAD) 2. #12 SAE (1 1/16-12 THREAD) 3. 3/4 NPTF (2000 PSI MAX) EXHAUST OPTIONS RELIEF OPTION Blank A B C D E F G H J K - 20EXX LEAVE BLANK FOR INLET WITHOUT RELIEF OR RELIEF PLUG NO RELIEF PLUG SHIM ADJUSTABLE RELIEF 500-1350 PSI SHIM ADJUSTABLE RELIEF 1351-1750 PSI SHIM ADJUSTABLE RELIEF 1751-2200 PSI SHIM ADJUSTABLE RELIEF 2201-3000 PSI ADJUSTABLE RELIEF 500-1350 PSI ADJUSTABLE RELIEF 1351-1750 PSI ADJUSTABLE RELIEF 1751-2200 PSI ADJUSTABLE RELIEF 2201-3000 PSI ADJUSTABLE RELIEF 3001-3500 RELIEF SETTINGS: THE LAST FOUR DIGITS REPRESENT THE RELIEF SETTING IN PSI 1-STANDARD OPEN CENTER OUTLET WITH CONVERSION PLUG 2-POWER BEYOND OUTLET WITH #10 SAE POWER BEYOND PORT 3-CLOSED CENTER OUTLET o 4-STANDARD OPEN CENTER WITH SOLENOID PILOT LINE SEALS o Often used with no relief. Review application VALVE ASSEMBLIES The Series 20 sectional body directional control valve can be ordered as separate sections as outlined or as a complete factory tested assembly. 7KLVZLOOQHHGWREHVSHFLÀHGZLWKHDFKRUGHU$QDVVHPEO\PRGHOQXPEHUZLOOEHDVVLJQHGDWWKHWLPHRIWKHRUGHU7KLVDVVHPEO\QXPEHUFDQWKHQ be used for future orders. ASSEMBLY MODEL NUMBER 20A - X X X X ;;;; 6HTXHQFHRI1XPEHUV7KLVQXPEHUZLOOEHDVVLJQHGWRÀQDOYDOYHWREHDVVHPEOHGDQGWHVWHGDWWKHIDFWRU\(DFKQHZRUGHURU TXRWHZLOOEHDVVLJQHGDQHZDVVHPEO\PRGHOQXPEHU CATV 5-03-16-03 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 12 &13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V5 CROSS SECTION OF 20P1BA1DA PARALLEL WORK SECTION VALVES SPOOLS AND SPOOL ATTACHMENTS B OPTION NDETENT SPOOL-OUT W/ SPRING CENTER SPOOL OPTION 'A' - 3 WAY 3 POSITION FOR USE WITH SINGLE ACTING CYLINDERS OR NON-REVERSIBLE MOTORS. THE 'B' WORK PORT IS BLOCKED IN NEUTRAL. SPOOL OPTION A OPTION ASPRING CENTER TO NEUTRAL SPOOL OPTION 'B' - 4 WAY 3 POSITION FOR USE WITH DOUBLE ACTING CYLINDERS OR REVERSIBLE MOTORS. THE WORK PORTS ARE BLOCKED IN NEUTRAL. SPOOL OPTION B OPTION B3 POSITION DETENT SPOOL OPTION 'C' - 4 WAY 3 POSITION FREE FLOW MOTOR SPOOL. THE WORK PORTS ARE OPEN TO TANK IN NEUTRAL, ALLOWING A MOTOR TO COAST OR A CYLINDER TO FLOAT. SPOOL OPTION C OPTION DFLOAT DETENT WITH SPRING CENTER SPOOL OPTION 'D' - 4 WAY 4 POSITION FLOAT. SAME AS 4 WAY 3 POSITION WITH THE ADDITION OF A FOURTH POSITION FLOAT. THE SPOOL IS DETENTED IN THE FLOAT POSITION AND SPRING CENTERED TO NEUTRAL FROM THE 'A' OR 'B' POWER POSITION SPOOL OPTION D 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 6-10-11-01 CROSS SECTION OF TANDEM WORK SECTION AND LOCK SECTION THE LOCK SECTION BODY HAS AN "L" ON THE LEFT SIDE OF THE "B" WORK PORT B WORK PORT SHOWN WITH MICRO-SWITCH OPTION J A WORK PORT B WORK PORT THE CASTING NUMBER "C-638" IS ON THE RIGHT SIDE OF WORK SECTION BODY THE CASTING NUMBER "C-637" IS ON THE RIGHT SIDE OF WORK SECTION BODY LOCK SECTION TANDEM SECTION MODEL 20P PARALLEL CIRCUIT MODEL 20T TANDEM CIRCUITS 3DUDOOHOFLUFXLWFRQVWUXFWLRQLVWKHPRVWFRPPRQ :KHQDQ\RQHRIWKHVSRROVLQDYDOYHEDQNLV VKLIWHGLWEORFNVRIIWKHRSHQFHQWHUSDVVDJH7KH RLOWKHQÁRZVLQWRWKHSDUDOOHOFLUFXLWFRUHPDNLQJ RLODYDLODEOHWRDOOVSRROV,IPRUHWKDQRQHVSRRO LVIXOO\VKLIWHGWKHQRLOZLOOJRWRWKHVHFWLRQZLWK WKHORZHVWSUHVVXUHUHTXLUHPHQWV,WLVSRVVLEOH KRZHYHU WR PHWHU ÁRZ WR WKH VSRRO ZLWK WKH OHDVW ORDG DQG SRZHU WZR XQHTXDO ORDGV 7KH VFKHPDWLFEHORZVKRZVDWKUHHVHFWLRQSDUDOOHO FLUFXLWVWDFNYDOYH 7DQGHP FLUFXLW FRQVWUXFWLRQ LV DOVR UHIHUUHG WR DVSULRULW\FLUFXLW:KHQWKHVSRRORIDVHFWLRQLV VKLIWHGRLOLVFXWRIIWRDOOGRZQVWUHDPVHFWLRQV 7KXVWKHVHFWLRQQHDUHVWWRWKHLQOHWKDVSULRULW\ RYHUWKHRWKHUVHFWLRQVLQWKHYDOYHEDQN,IPRUH WKDQRQHVSRROLVIXOO\VKLIWHGDOOWKHRLOZLOOJRWR WKHVHFWLRQQHDUHVWWRWKHLQOHW0HWHULQJWKHXS VWUHDPVHFWLRQZLOODOORZWZRVHFWLRQVWRRSHUDWH DWWKHVDPHWLPH7KHVFKHPDWLFEHORZVKRZVD WKUHHVHFWLRQWDQGHPFLUFXLWVWDFNYDOYH THE POWER CORE OF ALL SECTIONS IN THE VALVE STACK ARE CONNECTED TOGETHER BY THE PARALLEL CORE THAT RUNS THROUGH THE LENGTH OF THE VALVE THE POWER CORE OF A WORK SECTION IS FED BY THE OIL EXITING THE OPEN CENTER OF THE ADJACENT UPSTREAM WORK SECTION COMBINED PARALLEL/ TANDEM CIRCUITS 3DUDOOHO DQG WDQGHP FLUFXLW ZRUN VHFWLRQV FDQ EHFRPELQHGLQWKHVDPHYDOYHEDQN%HORZWKH VW DQG ODVW VHFWLRQV DUH SDUDOOHO DQG WKH QG LV WDQGHP 7KH VW SDUDOOHO VHFWLRQ KDV SULRULW\ RYHU WKH RWKHU WZR 7KH QG DQG UG VHFWLRQV DUHLQSDUDOOHOZLWKHDFKRWKHU,IWKHVSRRORIWKH VWVHFWLRQLVVKLIWHGLWZLOOFXWRIIRLOWRWKHRWKHU WZR,IWKHVSRROVRIWKHQGDQGUGVHFWLRQDUH ERWKVKLIWHGRLOZLOOJRWRWKHRQHZLWKWKHOHDVW UHVLVWDQFH,WVKRXOGEHQRWHGWKDWLWLVWKHVHFWLRQ MXVWSULRUWRWKHWDQGHPVHFWLRQWKDWKDVSULRULW\ QRWWKHWDQGHPVHFWLRQ)XUWKHULIDSDUDOOHOVHFWLRQ LVSODFHGMXVWDIWHUDWDQGHPWKHWZRVHFWLRQVZLOO EHLQDSDUDOOHO 20P PARALLEL WORK SECTIONS 20T TANDEM WORK SECTION LOAD CHECK OPEN CENTER APPLICATIONS CLOSED CENTER APPLICATIONS (DFKZRUNSRUWRIWKH6HULHVVWDFNYDOYHKDV DVHSDUDWHORDGFKHFN7KHORDGFKHFNSUHYHQWV WKH IDOO RI D F\OLQGHU DV WKH VSRRO LV VKLIWHG ,W DOVRSUHYHQWVWKHEDFNÁRZRIRLOIURPWKHZRUN SRUWWRWKHLQOHW7KHSXPSPXVWEXLOGXSHQRXJK SUHVVXUHWRRYHUFRPHWKHSUHVVXUHRQWKHZRUN SRUWFDXVHGE\WKHZHLJKWRIWKHORDGEHIRUHWKH F\OLQGHUFDQPRYH 7KH VWDQGDUG 6HULHV VWDFN YDOYH LV RSHQ FHQWHU:KHQWKHVSRROVDUHLQQHXWUDOK\GUDXOLF RLOLVGLUHFWHGIURPWKHLQOHWWRWKHRXWOHWRUSRZHU EH\RQGWKURXJKWKHRSHQFHQWHUFRUH0RYLQJRQH RUPRUHVSRROVFORVHVRIIWKHRSHQFHQWHUFRUHDQG GLUHFWVRLOWRWKHZRUNSRUWV2SHQFHQWHUV\VWHPV PRVWRIWHQFRQWDLQÀ[HGGLVSODFHPHQWSXPSVOLNH 7KH3ULQFH63VHULHVJHDUSXPSV 3/($6(127(WKDWWKHORDGFKHFNKDVQRWKLQJWR GRZLWKKRZZHOOWKHYDOYHZLOOKROGXSDF\OLQGHU ZLWK WKH VSRRO LQ QHXWUDO 7KH ORDG FKHFN LV IXQFWLRQDORQO\ZKHQWKHVSRROLVVKLIWHG 7KH6HULHV VWDFNYDOYH FDQEH FRQYHUWHG WR FORVHGFHQWHUE\DGGLQJWKHFORVHGFHQWHUSOXJ WR WKH RXWOHW VHFWLRQ 7KLV EORFNV RII WKH RSHQ FHQWHU FRUH ZKHQ WKH VSRROV DUH LQ QHXWUDO 7KHVHV\VWHPVRIWHQXVHDYDULDEOHGLVSODFHPHQW SUHVVXUH FRPSHQVDWHG SXPS WKDW OLPLWV WKH PD[LPXPSUHVVXUH:KHQVSRROVDUHLQQHXWUDO V\VWHPSUHVVXUHLVPDLQWDLQHGDWLQOHWRIWKHYDOYH $UHOLHILVQRUPDOO\QRWUHTXLUHGRUPXVWEHVHWDWD KLJKHUSUHVVXUHWKDQWKHSXPSFRPSHQVDWRU 3/($6(127(WKDWWKHPD[LPXPSUHVVXUHLQDQ RSHQFHQWHUV\VWHPLVFRQWUROOHGE\DUHOLHIYDOYH 3/($6( 127( WKDW WKLV FORVHG FHQWHU RSWLRQ 7KH6HULHVLQOHWVHFWLRQVDUHDYDLODEOHZLWKD GRHVQRWSURYLGHIRUWKHGUDLQRIIRIVWDQGE\VSRRO OHDNDJH7KLVFDQDOORZDYHU\VPDOODPRXQWRIRLO EXLOWLQLQOHWUHOLHIIRUWKLVSXUSRVH WRHQWHUWKHZRUNSRUWVZKHQLQQHXWUDO CATV 7-10-11-01 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 VALVES A WORK PORT THE TANDEM SECTION BODY HAS A "T" ON THE LEFT SIDE OF THE "B" WORK PORT SERIES CIRCUIT SERIES 20 WORK SECTIONS CROSS SECTION OF SERIES SECTION ARROW INDICATES DIRECTION OF OIL FLOW & POINTS TOWARDS OUTLET SECTION DIRECTION OF FLOW TOWARDS OUTLET SECTION ‘A’ WORK PORT ‘C-630’ CASTING NO. O-RING GROOVES SHIM ADJUSTABLE RELIEF SHOWN ADJUSTABLE RELIEF SHOWN VALVES HANDLE OPTION 7 SHOWN HERE CLOSED CENTER APPLICATIONS SPOOL ATTACHMENT OPTION ‘A’ SHOWN HERE V8 For solenoid operation with series sections and a 20U utility section, there needs to be a Series 20 WDQGHPVHFWLRQZLWKSLORWSDVVDJHZD\VEHWZHHQ the series section and the utility section. ,QWKHYDOYHDVVHPEO\VKRZQEHORZWKHÀUVWDQG fourth sections are parallel. The second section LVVHULHVWKHWKLUGVHFWLRQLVWDQGHP7KHÀUVW parallel section has priority over all downstream valves. When the spool of the first parallel section is actuated, the return oil from the work SRUWLVGLUHFWHGWRWKHWDQNFRUHWKXVRLOÁRZWR downstream sections is cut off. The second and third sections are in series with each other as well as the second and fourth sections. The third and fourth sections are in parallel with each other. PORT A PORT B PORT A PORT B PORT A PORT B PORT A 20P PARALLEL PORT B 20T TANDEM The Series 20 series sections may be stacked with 20P parallel circuit valve sections. When XVLQJDVHULHVVHFWLRQWKHLPPHGLDWHGRZQVWUHDP section needs to be a series, tandem, or outlet section. 20P sections can be either in front of the Series 20 series sections or behind a combination of series and tandem sections. 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 20S SERIES A series circuit valve is most commonly used to control more than one hydraulic component simultaneously. The entire circuit flow is available to each valve section that is actuated. In a two spool series valve with both spools DFWXDWHG WKH RLO ÁRZV IURP WKH LQOHW WR WKH ZRUNSRUWRIWKHÀUVWVHFWLRQ7KHUHWXUQÁRZRI WKHÀUVWVHFWLRQLVGLUHFWHGWRWKHRSHQFHQWHU core of the second section. (In a parallel valve the return oil from the work port is directed to the tank core.) From the open center core of WKHVHFRQGVHFWLRQWKHRLOÁRZVWRWKHZRUN SRUWZLWKWKHUHWXUQRLOJRLQJWRWKHRXWOHW,Q a series circuit valve, the summation of the pressures required for each work section will equal the total pressure required for the circuit. The total pressure required must not exceed WKHV\VWHPUHOLHIVHWWLQJIRUWKHSXPSSUHVVXUH UDWLQJ,WLVQRWUHTXLUHGWRKDYHD6HULHV series section as the last section, unless series ÁRZLVUHTXLUHGWRDGRZQVWUHDPYDOYH,QWKLV DSSOLFDWLRQDSRZHUEH\RQGSOXJPXVWEHXVHG in the outlet section. COMBINED SERIES/ PARALLEL CIRCUITS 20P PARALLEL MODEL 20S SERIES CIRCUIT The Series 20 Series circuit valve sections cannot be used in a closed center valve assembly. CATV 8-03-16-02 INLET COVER DIMENSIONS TOP INLET WORK SECTIONS DIMENSIONS TOP OUTLET PART NUMBER WILL BE STAMPED IN THIS LOCATION 2.69 .50 .344 DIA 1.44 2.25 IN OUTLET TANK A WORK PORT 2.88 B WORK PORT INLET 1.75 .34 SYSTEM RELIEF 1.13 A WORK PORT RELIEF OPTION B WORK PORT RELIEF OPTION B SPOOL TRAVEL .312 TO WORK .531 TO FLOAT A 3.06 P .81 4.25 IN 1.88 .88 1.75 .88 1.75 1.44 2.56 PART NUMBER WILL BE STAMPED IN THIS LOCATION 2.75 DIMENSIONAL DATA .250 DIA .283 DIA 1.00 1.70 5.50 OUTLET COVER DIMENSIONS 5.38 2.69 5.38 2.69 1.00 .344 DIA (2) LOCATION FOR POWER BEYOND OUTLET OR CLOSED CENTER CONVERSION PLUG OUTLET PORT C- 1.75 VALVES 1.00 63 2 TANK SEE CHART COLUMN A 1.25 B WORK PORT 1.69 1.38 A WORK PORT .50 NUMBER OF WORK SECTIONS 1 4 5 A 2.50 4.25 6.00 7.75 9.50 11.25 13.00 14.75 16.50 18.25 B 4.88 6.63 8.38 10.13 11.88 13.63 15.38 17.13 18.88 20.63 INLET RELIEF TOP OUTLET TOP INLET 2 3 6 7 8 9 10 SIDE OUTLET PORT SIDE INLET PORT TANK IN 8.25 2.25 4.38 .81 1.25 IN .88 .88 12.13 SEE CHART COLUMN B 13.22 CATV-9-11-14-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V9 WORK PORT RELIEF CARTRIDGES INLET RELIEF CARTRIDGES OPTION K ANTI-CAVITATION CHECK This option allows oil to be drawn from the tank core into the work port if there is a vacuum on the work port. This vacuum would be caused by a overrunning motor or cylinder. The check will be open whenever the pressure in the tank core is higher than that in the work port. OPTIONS B, C, D, AND E, SHIM ADJUSTABLE PORT RELIEF A port relief can be installed to limit the pressure at the work port to less than the system pressure. Also, it can be installed to provide spike pressure protection when the spool is in the neutral position. The pressure of these reliefs can be changed by changing shims. OPTION A NO RELIEF When no main inlet relief is required the no relief plug is installed. All inlet sections have the relief cavity machined so a inlet relief can be installed LQWKHÀHOG OPTIONS B, C, D, AND E, SHIM ADJUSTABLE INLET RELIEF These options provide for an internally shim adjustable main inlet relief. The relief is a hydraulically dampened differential poppet design. This provides for smooth quiet operation in a relief that is moderately tolerant to contamination. The pressure of these reliefs can be changed, within the VSHFLÀHGUDQJHE\FKDQJLQJVKLPV7KLVUHOLHILVDOVRDYDLODEOHZLWK stainless steel relief springs, consult factory. OPTIONS F, G, H, AND J, ADJUSTABLE PORT RELIEF This is the same differential poppet type relief as above but externally adjustable ZLWKLQWKHVSHFLÀHG range. OUTLET SECTION OPTIONS OPTIONS F, G, H, AND J, ADJUSTABLE RELIEF This is the same relief as above except it is externally adjustable, ZLWKLQWKHVSHFLÀHGUDQJH HANDLE OPTIONS NOTE: HANDLES ARE COATED WITH BLACK RUBBER VALVES OPTION 1 STANDARD OPEN CENTER WITH CONVERSION PLUG This is the standard outlet option. This option allows for conversion in the ÀHOGIRUSRZHUEH\RQGRUFORVHGFHQWHUDSSOLFDWLRQV:KHQWKHVSRROVDUH in neutral the inlet is unloaded to tank. OPTION 3 CLOSED CENTER OUTLET This option provides for closed center operation. This is typically used with a variable displacement pressure compensated pump or in a system with an unloading valve. When the spools are in neutral the inlet port is blocked. OPTION 2 POWER BEYOND WITH #10 SAE BEYOND PORT This option provides for a high pressure power beyond port. This would be used if a valve is to be added downstream. The outlet must be connected to tank. When the spools are in neutral the inlet is connected to power beyond port. SERIES 20 COMBINATION 3 WAY AND COMBINED FLOW MID-INLET SECTION 3 Way 3 Position Work Port Mid-Inlet Port 20TM 3 A A 1 E A - X X X X PORT SIZE* SPOOL ACTION* HANDLE OPTIONS * MID-INLET RELIEF RELIEF TYPE STANDARD SETTING OPTION NO. 1350 PSI @ 10 GPM 1750 PSI @ 10 GPM 2200 PSI @ 10 GPM 2500 PSI @ 10 GPM B C D E 1350 PSI @ 10 GPM 1750 PSI @ 10 GPM 2200 PSI @ 10 GPM 2500 PSI @ 10 GPM F G H J NO RELIEF Mid-Inlet Relief B A SHIM ADJUSTABLE ADJUSTABLE (not available with handle option 1) T DIGITS SPECIFY A MID INLET NON-STANDARD RELIEF PRESSURE IN PSI. LEAVE BLANK FOR STANDARD SETTING. A WORK PORT RELIEF * For nonstandard settings, add setting in PSI (-XXXX) after mid inlet relief setting. *See Series 20 Tandem Center work section order code for additional options. *See Series 20 Tandem Center work section for dimensional data. V10 Description: This section acts as a combination mid-inlet and 3 way 3 position section. The mid-inlet provides an inlet port for a second pump mid stream in the stack valve. The A port is the mid-inlet port DQGSURYLGHVFRPELQHGÁRZIRUWKLVVHFWLRQDQGDQ\GRZQVWUHDPVHFWLRQV7KH%SRUWDQGWKHUHVW of the section function the same as a 3 way 3 position section. When shifted any upstream sections WDNHSULRULW\RIWKHPDLQLQOHWÁRZRYHUGRZQVWUHDPVHFWLRQV%RWKDQLQOHWUHOLHIDQGDPLGLQOHWUHOLHI are required to provide relief protection when both upstream and downstream sections are shifted. 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV-10-11-14-03 SERIES 20 MID-INLET SECTION Mid-Inlet Port 20IM X X X X -XXXX FLOW OPTION C - COMBINED FLOW S - SPLIT FLOW 1.75 LAST FOUR DIGITS SPECIFY A NONSTANDARD RELIEF PRESSURE IN PSI. LEAVE BLANK FOR STANDARD SETTING. PORT SIZE 1.12 10 - #10 SAE (7/8-14 THREAD) 20 - #12 SAE (1 1/16-12 THREAD) 30 - 1/2-NPTF 40 - 3/4-NPTF Mid-Inlet Relief Cartridge/Plug MID-INLET RELIEF OPTIONS: Install pipe plug in this location for Flow Option 'C' (Combined) OPTION NO. BODY LESS RELIEF CARTRIDGE/PLUG -- A NO-RELIEF PLUG -- B C D E SHIM ADJUSTABLE 500-1350 PSI SHIM ADJUSTABLE 1350-1750 PSI SHIM ADJUSTABLE 1750-2200 PSI SHIM ADJUSTABLE 2200-3000 PSI 1350 PSI 1750 PSI 2200 PSI 2500 PSI F G H J K ADJUSTABLE 500-1350 PSI ADJUSTABLE 1350-1750 PSI ADJUSTABLE 1750-2200 PSI ADJUSTABLE 2200-3000 PSI ADJUSTABLE 3000-3500 PSI 1350 PSI 1750 PSI 2200 PSI 2500 PSI 3250 PSI "BLANK" 5.56 Install pipe plug in this location for Flow Option 'S' (Split) Section can be converted from C to S, or S to C, prior to installing section in the stack valve assy. STD. SETTING @ 10 GPM RELIEF TYPE TEST DATA P T INLET TO OUTLET PRESSURE DROP P 350 T INLET TO OUTLET PRESSURE DROP 350 300 250 4 SECTION 200 8 SECTION 250 6 SECTION PSI PSI 300 8 SECTION 6 SECTION 4 SECTION 200 2 SECTION 2 SECTION 150 150 100 75 50 25 100 75 50 25 5 VALVES LEFT 'IN' TO RIGHT 'OUT' LEFT 'IN' TO LEFT 'OUT' 10 15 20 25 GPM 5 10 15 20 25 GPM ONE WAY WORK PORT RESTRICTOR FOR SERIES 20 SECTIONS This restrictor will restrict oil in one direction and DOORZIUHHÁRZLQWKHRSSRVLWHGLUHFWLRQ7KLVUHVWULFWRU FRQVLVWVRIDQRULÀFHSODWHWKDWVLPSO\GURSVLQWRWKH #8 SAE or #10 SAE work port of a 20P, 20T, or 20L work section. PRESSURE DROP FOR PATH AND 350 NO. OF SECTIONS INDICATED 300 P PSI 250 200 P A OR B A OR B A OR B, 8 SECTION A OR B, 2 SECTION T, 8 SECTION T, 2 SECTION 150 Restricted Flow 100 75 50 25 5 10 15 20 25 GPM Oil 140 SUS at 110 degrees F. The pressure drop curves are representative, but the actual pressure drop will vary some from valve to valve. More detailed test data is available upon request. CATV-11-11-14-02 ORDERING INFORMATION HEX BRASS RESTRICTOR #8 HEX BRASS RESTRICTOR #10 Free Flow 670805XXX 670811000 The last three digits of part number DUHWKHRULÀFHVL]HLQWKRXVDQGWKVRIDQLQFK EXAMPLE: 670805062 .62 ORIFICE 670805125 .125 ORIFICE 670805000 NO ORIFICE 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V11 SERIES 20 FLOW CONTROL INLET SECTION Digits Specify A Non-Standard Relief Pressure in PSI. Leave blank for standard setting. Solenoid Option: 2PLWIRU)ORZ2SW¶0· 12 D – 12VDC Deutsch (DT04-2P) 20IF15 INLET PORT; #12 SAE ORB -XXXX MANUAL FLOW CONTROL CARTRIDGE Flow Control Option: M – Manual Control P – Electro-Proportional ADJ. RELIEF CARTRIDGE Pilot Operated Relief Adjustable From 2000-3500 PSI. 5.00 Standard Relief Setting: 2500 PSI @ 10 GPM MANUAL (OPT ‘M’) DESCRIPTION: This inlet incorporates a manually operated pressure FRPSHQVDWHGÁRZFRQWURO:LWKWKHÁRZFRQWURONQREWXUQHG IXOO\LQFORFNZLVHDOORIWKHLQOHWÁRZLVGLYHUWHGWRWKHWDQN FRUH%\WXUQLQJWKHÁRZFRQWURONQREFRXQWHUFORFNZLVHWKH LQOHWÁRZGLUHFWHGWRWKHSRZHUFRUHZLOOEHSURSRUWLRQDOO\ LQFUHDVHG$SSUR[LPDWHO\WXUQVYDULHVWKHFRQWUROOHGÁRZ IURPQRÁRZWR*300D[LPXPQXPEHURIWXUQVRQÁRZ control is approximately 8 turns.) 1.94 7.00 INLET INLET ELECTRO-PROPORTIONAL (OPT ‘P’) DESCRIPTION: VALVES REF: 20IF15M REF: 20IF15P12D This inlet incorporates a solenoid operated, electrically YDULDEOHSUHVVXUHFRPSHQVDWHGÁRZFRQWURO:LWKQRFXUUHQW JRLQJWKURXJKWKHVROHQRLGDOORIWKHLQOHWÁRZLVGLYHUWHGWR the tank core. By increasing the current through the solenoid, WKHÁRZEHLQJGLUHFWHGWRWKHSRZHUFRUHZLOOEHSURSRUWLRQDOO\ increased. (The current range is 400-1600 mA. At a current RIP$PD[FRQWUROOHGÁRZLVDSSUR[LPDWHO\*30 Control current is provided via a controller card providing a PWM signal. LD. CHECK CORE POWER CORE TANK CORE TEST DATA &XUUHQWYV5HJXODWHG)ORZ 6HULHV(OHFWUR3URSRUWLRQDO)ORZ&RQWURO,QOHW *30,QOHW)ORZ 30.0 30 1R/RDG5HJXODWHG)ORZ*30 1R/RDG5HJXODWHG)ORZ*30 7XUQVYV5HJXODWHG)ORZ 6HULHV0DQXDO)ORZ&RQWURO,QOHW *30,QOHW)ORZ 25 20 15 10 5 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 7XUQVIURP&ORVHG 25.0 20.0 Decreasing Current 15.0 Increasing Current 10.0 5.0 0.0 0 200 400 600 800 1000 1200 1400 1600 &RLO&XUUHQWP$ 3:0VLJQDOZLWK+]GLWKHU )ORZRYHU5HOLHIYV3UHVVXUH 6HULHV)ORZ&RQWURO,QOHW 5HOLHIVHWDWSVL#JSP 3000 ,QOHW3UHVVXUH36, 2500 2000 1500 1000 500 0 0 5 10 15 20 25 30 ,QOHW)ORZ*30 V12 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11 & 13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV-12-11-14-03 Directional Control Valves LOAD SENSE SECTIONS VALVES NEED NEW PIC Series “20”” STANDARD FEATURES ([WHQGHG/HQJWK1RWFKHVIRU9HU\)LQH0HWHULQJ 0DFKLQHG,QWHUQDO/DQGVIRU3UHFLVH Control and reduced Dead Band /RZ6WDQGE\3UHVVXUHV 6SRRO'HVLJQIRUUHGXFHG)ORZ)RUFHV /RZ6SRRO$FWXDWLQJ)RUFHV 8VHRI6WDQGDUG6HULHV,QOHW6HFWLRQV (20I) and Tie Rod Kits 6DPH0RXQWLQJ3DWWHUQDQG(QYHORSHDV 6WDQGDUG6HULHV9DOYH SPECIFICATIONS Pressure Rating 0D[LPXP2SHUDWLQJ3UHVVXUH SVL 0D[LPXP7DQN3UHVVXUH................... SVL Nominal Flow Rating ...........................*30 3OHDVH5HIHUWR3UHVVXUH'URSDQG)ORZ &KDUWVIRU<RXU$SSOLFDWLRQ CATV 13-07-13-02 Foot Mounting Maximum Operating Temp. .....................) /36HFWLRQ:HLJKW ................ $SSUR[,EV /(6HFWLRQ:HLJKW .................. $SSUR[,EV 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 SPECIAL SECTIONS AVAILABLE: Valves other than standard models listed can be made to order. Use order code Matrix below to generate a model number WKDWPHHWV\RXUUHTXLUHPHQWV,I\RXSUHIHUFRQWDFW\RXU6DOHV5HSUHVHQWDWLYHZLWK\RXUVSHFL¿FUHTXLUHPHQWVDQGDPRGHO number will be assigned for you. This model number can then be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. 2 0 XX X X X X X X WORK SECTION WORK SECTION TYPE PORT RELIEF “B” PORT RELIEF “A” LP-STANDARD LOAD SENSE SECTION LPC-LOAD SENSE PRESSURE COMPENSATED A - NO RELIEF B - SHIM ADJUSTABLE RELIEF 500-1350 PSI SET AT 1350 C - SHIM ADJUSTABLE RELIEF 1351-1750 PSI SET AT 1750 D - SHIM ADJUSTABLE RELIEF 1751-2200 PSI SET AT 2200 E - SHIM ADJUSTABLE RELIEF 2201-3000 PSI SET AT 2500 F - ADJUSTABLE RELIEF 500-1350 PSI SET AT 1350* G - ADJUSTABLE RELIEF 1351-1750 PSI SET AT 1750* H - ADJUSTABLE RELIEF 1751-2200 PSI SET AT 2200* J - ADJUSTABLE RELIEF 2201-3000 PSI SET AT 2500* K - ANTI-CAVITATION CHECK° L - PORT RELIEF/ANTI-CAV SHIM ADJ 500-1350 PSI SET AT 1350° M - PORT RELIEF/ANTI-CAV SHIM ADJ 1351-1750 PSI SET AT 1750° N - PORT RELIEF/ANTI-CAV SHIM ADJ 1751-2200 PSI SET AT 2200° R - PORT RELIEF/ANTI-CAV SHIM ADJ 2201-3000 PSI SET AT 2500° S - PORT RELIEF/ANTI-CAV ADJUSTABLE 500-1350 PSI SET AT 1350*° T - PORT RELIEF/ANTI-CAV ADJUSTABLE 1351-1750 PSI SET AT 1750*° W- PORT RELIEF/ANTI-CAV ADJUSTABLE 1751-2200 PSI SET AT 2200*° Y - PORT RELIEF/ANTI-CAV ADJUSTABLE 2201-3000 PSI SET AT 2500*° PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) 5. 3/8 NPTF (2000 PSI MAX) SPOOL TYPE H - 3 WAY 3 POSITION J - 4 WAY 3 POSITION K - 4 WAY 3 POSITION FREE FLOW MOTOR M - 4 WAY 4 POSITION FLOAT (USE WITH D SPOOL ACTION) J05 - 5 GPM PRESSURE COMP (LPC ONLY) J10 - 10 GPM PRESSURE COMP (LPC ONLY) J15 - 15 GPM PRESSURE COMP (LPC ONLY) SPOOL ACTIONS VALVES A - SPRING CENTER TO NEUTRAL B - 3 POSITION DETENT C - FRICTION DETENT D - FLOAT DETENT E - SPRING CENTER PNEUMATIC ACTUATOR F - 2 POSITION DETENT NEUTRAL & OUT (NO IN POSITION) H - HYDRAULIC ACTUATOR (USE HANDLE OPTION 7) J - SPRING CENTER W/MICROSWITCH (SWITCHES ON IN OR OUT)*** K - SPRING CENTER W/MICROSWITCH (SWTCHES ON SPOOL IN ONLY )*** M - SPRING CENTER DETENT IN N - SPRING CENTER DETENT OUT P - 2 POSITION DETENT NEUTRAL & IN (NO OUT POSITION) *ADJUSTABLE PORT RELIEF CARTRIDGES CANNOT BE USED ON THE “A” PORT END OF WORK SECTION WHEN THE STANDARD LEVER HANDLE IS USED BECAUSE OF INTERFERENCE °ANTI-CAVITATION CHECKS AND RELIEFS NOT AVAILABLE WITH LPC SECTIONS. WORK PORT RELIEFS ON 20LPC USE A DIFFERENT CARTRIDGE THAN THE STANDARD SERIES 20P CARTRIDGE FOR WORK PORT RELIEF SETTING OTHER THAN STANDARD 20P1BA1DH-18-20 “B” PORT RELIEF PRESSURE IN HUNDREDS EXAMPLE: 20=2000 PSI “A” PORT RELIEF PRESSURE IN HUNDREDS EXAMPLE: 18=1800 PSI HANDLE OPTIONS 1 - STANDARD LEVER HANDLE* 2 - LESS HANDLE ONLY 3 - LESS COMPLETE HANDLE 4 - VERTICAL LEVER HANDLE* 7 - BLANK FOR OPTIONAL JOYSTICK HANDLE * LEVERS ARE COATED WITH BLACK RUBBER ***MICROSWITCH INCLUDED. SEE PAGE 12 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING LOAD SENSE OUTLET SECTION 2 0 LE X X OUTLET TYPE LE - STANDARD LOAD SENSE OUTLET PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #12 SAE (1 1/16-12 THREAD) 3. 3/4 NPTF (2000 PSI MAX) LOAD SENSE PORT OPTIONS 1. #4 SAE WITH DRAIN ORIFICE 2. #4 SAE WITHOUT DRAIN ORIFICE 3. OUTLET FOR USE WITH 20ILFS INLET (OUTLET SEALS FOR SOLENOID PILOT LINES) 7KH3ULQFH/(RXWOHWLQFOXGHVDORDGVHQVHSRUWLQDFDUWULGJHWKDWLVLQVWDOOHGLQWKHVHFWLRQ7KHUHDUHWZRYHUVLRQVRIWKHFDUWULGJHRQHZLWKDORDG VHQVHOLQHGUDLQRULÀFHDQGRQHZLWKRXWDGUDLQRULÀFH7KHUHLVQRUPDOO\DGUDLQRULÀFHLQHLWKHUWKHYDOYHRUWKHSXPSFRQWUROV&DUWULGJHVFDQEH FKDQJHGLQWKHÀHOGWRFKDQJHWKHFRQÀJXUDWLRQ3RZHUEH\RQGLVQRWDYDLODEOHLQDORDGVHQVHV\VWHP V14 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 12 & 13 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 14-03-16-03 CROSS SECTION OF LOAD SENSE & LOAD SENSE PRESSURE COMPENSATED WORK SECTIONS PARALLEL CORE LOAD CHECK 'B' WORK PORT LOAD SENSE SECTION HAS 'LS' CAST ON THE LEFT SIDE OF THE 'B' WORK PORT CASTING NUMBER C-814 ON THE RIGHT SIDE OF WORK SECTION BODY PARALLEL CORE PRESSURE COMPENSATING SPOOL 'B' WORK PORT LOAD SENSE SECTION HAS 'LS' CAST ON THE LEFT SIDE OF THE 'B' WORK PORT 'A' WORK PORT 'A' WORK PORT LOAD SENSE PASSAGE LOAD SENSE PASSAGE EXTENDED NOTCHES MACHINED INTO SPOOL PROVIDE EXTRA FINE METERING TANK CORE CASTING NUMBER C-814 ON THE RIGHT SIDE OF WORK SECTION BODY MODEL 20LP LOAD SENSE & 20LPC LOAD SENSE PRESSURE COMPENSATED CIRCUITS 7KHUHDUHDQXPEHURIEHQHÀWVWRORDGVHQVHV\VWHPVRQHRIWKHSULPDU\RQHVEHLQJLQWKHPHWHULQJRIWKHÁRZWRWKHZRUNSRUWV 0HWHULQJLVW\SLFDOO\DFFRPSOLVKHGZKHQWKHÁRZSDVVHVWKURXJKPHWHULQJQRWFKHVLQWKHVSRRO,QDORDGVHQVHYDOYHWKHSUHVVXUH WKDWGULYHVWKHÁRZWKURXJKWKHQRWFKHVLVW\SLFDOO\OLPLWHGWRWKHUHODWLYHO\ORZDQGQHDUO\FRQVWDQWGLIIHUHQWLDOSUHVVXUH7KLVUHODWLYHO\ ORZGLIIHUHQWLDOSUHVVXUHPDNHVWKHQRWFKHVPRUHHIIHFWLYHDQGJLYHVPRUHUHVROXWLRQLQUHJDUGWRVSRROWUDYHOYHUVXVÁRZRXWRI WKHZRUNSRUW$OVRWKLV´UHVROXWLRQµUHPDLQVUHODWLYHO\WKHVDPHUHJDUGOHVVRIWKHSUHVVXUHUHTXLUHGDWWKHZRUNSRUW7KHPHWHULQJ QRWFKHVLQWKH3ULQFHORDGVHQVHYDOYHKDYHEHHQRSWLPL]HGWRJLYHH[FHOOHQWPHWHULQJFKDUDFWHULVWLFVRYHUDQH[WHQGHGSRUWLRQRIWKH VSRROWUDYHODQGRYHUWKHIXOOÁRZUDWLQJRIWKHYDOYH7KHLQWHUQDOODQGVRIWKHFDVWLQJKDYHDOVREHHQPDFKLQHGWRJLYHUHSHDWDEOH SUHFLVHFRQWUROWRWKHPHWHULQJFKDUDFWHULVWLFV$QRWKHUEHQHÀWWRORDGVHQVHYDOYHVLVWKDWLQWKHPLQLPXPÁRZVWDQGE\PRGHWKH SXPSRQO\KDVWRJHQHUDWHWKHUDWKHUORZGLIIHUHQWLDOSUHVVXUHWKXVVDYLQJHQHUJ\DVFRPSDUHGWRW\SLFDORSHQFHQWHURUVWDQGDUG closed center systems. 7KH6HULHV/3&ORDGVHQVHSUHVVXUHFRPSHQVDWHGYDOYHLQFRUSRUDWHVDSUHVVXUHFRPSHQVDWRUXSVWUHDPWRWKHPHWHULQJQRWFKHV RQWKHVSRRO´SUHFRPSµ:LWKHLWKHUDIXOO\VKLIWHGRUSDUWLDOO\VKLIWHGVSRROZRUNSRUWÁRZZLOOUHPDLQFRQVWDQWUHJDUGOHVVRIFKDQJLQJ ORDGSUHVVXUHUHTXLUHPHQWV3UHVVXUHFRPSHQVDWHGVHFWLRQVDUHSDUWLFXODUO\XVHIXOLQDSSOLFDWLRQVZKHUHWKHPHWHULQJRIÁRZZLWK YDU\LQJSUHVVXUHDQGÁRZFRQGLWLRQVLVUHTXLUHG7KH/3&VHFWLRQVKDYHÁRZUDWHGVSRROVWKDWGHWHUPLQHWKHPD[LPXPÁRZIURP WKHLQGLYLGXDOZRUNVHFWLRQ)RULQVWDQFHWKHPD[LPXPÁRZIURPDZRUNVHFWLRQVZLWKD-VSRROLVJSP0HWHULQJQRWFKHVH[WHQG WRWKHIXOOWUDYHORIWKHVSRRO7KHORZHUÁRZVSRROVZLOOSURYLGHLQFUHDVHGÁRZYVVSRROWUDYHOUHVROXWLRQ:LWKSDUDOOHOFLUFXLWU\PXOWLSOH VHFWLRQVFDQEHXVHGVLPXOWDQHRXVO\WRPHWHUÁRZ,IWKHVXPRIWKHÁRZUDWLQJRIWKHVKLIWHGVSRROVLVOHVVWKDQWKHÁRZUDWLQJRI WKHSXPSDOOVHFWLRQVZLOOUHFHLYHÁRZ,IWKHFDOOIRUÁRZEDVHGRQVSRROSRVLWLRQIURPDOOZRUNVHFWLRQVFDOOVIRUPRUHÁRZWKDQWKH RXWSXWRIWKHSXPSWKHUHPD\EHVRPHGLYLVLRQRIÁ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ÀFDOO\GHVLJQHGWREHXVHGZLWKDSUHVVXUHÁRZFRPSHQVDWHGSXPSFRPPRQO\ NQRZQDVDORDGVHQVHSXPS7KHYDOYHLVDSDUDOOHOFLUFXLWFORVHGFHQWHUGHVLJQZKHUHÁRZGRHVQRWÁRZWKURXJKWKHYDOYHZKHQ WKHVSRROVDUHFHQWHUHG$ORDGVHQVHVLJQDOOLQHPXVWEHFRQQHFWHGWRWKHORDGVHQVHSRUWRQWKHSXPSDQGWRWKHORDGVHQVHSRUW RQWKH/(RXWOHWVHFWLRQRIWKHYDOYH7KHSUHVVXUHÁRZFRPSHQVDWRUSRUWLRQRIDORDGVHQVHSXPSZLOOPDLQWDLQZLWKLQLWVÁRZ and pressure limitations) an output pressure equal to the pressure at the load sense port plus the load sense differential pressure. 7KHGLIIHUHQWLDOSUHVVXUHLVW\SLFDOO\EHWZHHQDQGSVL7KHYDOYHLVGHVLJQHGVRWKDWZKHQDVSRROLVVKLIWHGWKHSUHVVXUHDW WKHRXWÁRZZRUNSRUWLVSUHVHQWHGWRWKHYDOYHVORDGVHQVHSRUW7KHYDOYHLQFRUSRUDWHVORJLFDQGORDGVHQVHFKHFNYDOYHVVRWKDW ZKHQPXOWLSOHVSRROVDUHVKLIWHGWKHKLJKHVWSUHVVXUHRIDQ\RIWKHZRUNSRUWVLVGLUHFWHGWRWKHORDGVHQVHSRUW$ORDGVHQVHOLQH EOHHGRULÀFHQHHGVWREHSUHVHQWLQHLWKHUWKH3ULQFHORDGVHQVHRXWOHWRUWKHORDGVHQVHSXPSFRQWUROV7KHEOHHGRULÀFHZLOOSUHYHQW KLJKSUHVVXUHIURPEHLQJWUDSSHGLQWKHORDGVHQVHOLQHDQGVHQGLQJIDOVHVLJQDOVWRWKHSXPS LOAD SENSE OUTLET DIMENTIONS LOAD SENSE WORK SECTION DIMENSIONS 5.38 ø.344 (2) 1.38 2.69 1.75 1.00 .34 1.44 2.88 LOAD SENSE PORT OUTLET PORT 4.25 1.25 1.44 2.56 1.69 2.75 5.50 ø.250 1.00 1.70 ø.283 TEST DATA PRESSURE DROP - WORK PORT TO TANK 300 PRESSURE DROP PSI VALVES PRESSURE DROP PSI PRESSURE DROP - INLET TO WORK PORT 250 8 SECTIONS 200 150 100 2 SECTIONS 50 0 120 100 8 SECTIONS 80 60 40 2 SECTIONS 20 0 0 5 10 15 20 25 30 FLOW GPM 0 5 10 15 20 25 30 FLOW GPM WORK PORT FLOW VS. SPOOL POSITION 30 FLOW (GPM) 25 20 15 350 PSI LOAD SENSE DIFFERENTIAL 10 250 PSI LOAD SENSE DIFFERENTIAL 5 0 0.00 0.05 0.10 0.15 0.20 0.25 0.30 SPOOL DISPLACEMENT (IN) 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 16-07-13-02 SERIES 20 LOAD SENSE INLET (FOR FIXED DISPLACEMENT PUMP) HANDLE END (FRONT) OF SECTION 20ILF25 PRESSURE COMPENSATING REGULATOR CARTRIDGE – XXXX COMPENSATOR SETTING: 090 – 90 PSI COMPENSATOR 150 – 150 PSI COMPENSATOR (STANDARD) 230 – 230 PSI COMPENSATOR ADJUSTABLE RELIEF CARTRIDGE INLET PORT; #12 SAE ORB DIGITS SPECIFY A NON-STANDARD RELIEF PRESSURE IN PSI. LEAVE BLANK FOR STANDARD SETTING. INLET 4.00 LOAD CHECK CORE 1.94 TANK CORE LOAD SENSE LINE 6.60 SERIES 20 LOAD SENSE INLET (FOR FIXED DISPLACEMENT PUMP w/SOLENOID OPERATORS) HANDLE END (FRONT) OF SECTION G IN 20ILFS65 FILTER CARTRIDGE COMPENSATOR SETTING: 230 – 230 PSI COMPENSATOR PRESSURE COMPENSATING REGULATOR CARTRIDGE FILTER INLET PORT #16 SAE ORB – XXXX ADJUSTABLE RELIEF CARTRIDGE DIGITS SPECIFY A NON-STANDARD RELIEF PRESSURE IN PSI. LEAVE BLANK FOR STANDARD SETTING. TANK PORT – #16 SAE ORB IN 4.50 G PILOT PILOT LINE LOAD CHECK CORE TANK T 6.60 TANK CORE LOAD SENSE LINE 2.94 APPLICATION NOTES – 20ILF and 20ILFS: 7KHVHLQOHWVDUHIRUXVHZLWKDÀ[HGGLVSODFHPHQWSXPSVXFK DVDJHDUSXPSDQG3ULQFH6HULHVORDGVHQVHVHFWLRQV :KHQDOOVSRROVDUHFHQWHUHGWKHLQOHWDOORZVWKHSXPSÁRZWR be diverted to tank at relatively low pressure. 3. :KHQDVSRROLVVKLIWHGWKHFRPSHQVDWRUGLUHFWVWKHÁRZWRWKH ZRUNSRUWDWDÁRZDQGSUHVVXUHUHODWLYHWRWKHZRUNSRUWORDGVHQVH SUHVVXUH7KHLQOHWUHWDLQVWKHHQKDQFHGPHWHULQJFRQWURORIWKH load sense work sections. 4. For the 20ILF inlet, the 150 psi compensator is standard. It is W\SLFDOO\XVHGZLWKÁRZVXSWRDSSUR[LPDWHO\JSP)RUORZHU ÁRZV D SVL FRPSHQVDWRU FDQ EH XVHG )RU KLJKHU ÁRZV D 230 psi compensator can be used. For the 20ILFS inlet, a 230 psi compensator is standard. In the 20ILFS, the compensator JHQHUDWHVSLORWSUHVVXUHWRLQLWLDWHDVSRROVKLIWZKHQDVROHQRLG LVHQHUJL]HG/RDGLQGXFHGSUHVVXUHLVUHTXLUHGWRFRPSOHWHDQG then maintain the spool shift. )RU WKH ,/)6 WKH ÁRZ WR WKH VROHQRLG FDUWULGJHV LV ÀOWHUHG WKURXJKDMUHSODFHDEOHFDUWULGJHSUHVVXUHÀOWHU2QO\WKHSLORW ÁRZLVÀOWHUHGWKXVSURYLGLQJDORQJÀOWHUOLIH 6. A Series 20 load sense outlet (20LEx1 for the 20ILF or a 20LEx3 for the 20ILFS) must be used in the stack valve assembly. 7KHORDGVHQVHSRUWRQWKHRXWOHWQHHGVWREHSOXJJHGZLWKD VWHHOSOXJ7KHUHLVQRH[WHUQDOORDGVHQVHOLQH TEST DATA 20ILF PRESSURE DROP INLET TO TANK 20ILF RELIEF CURVE 350.0 SET @ 10 GPM 3500 230 PSI COMPENSATOR 300.0 250.0 PRESSURE (PSI) PRESSURE DROP (PSI) LEFT IN TO RIGHT OUT (3 WORK SECTIONS) 150 PSI COMPENSATOR 200.0 150.0 100.0 90 PSI COMPENSATOR 50.0 0.0 0.0 2500 PSI 2500 2000 PSI 2000 1500 1000 500 0 5.0 10.0 15.0 20.0 INLET FLOW (GPM) CATV 17-03-16-03 3000 PSI 3000 25.0 30.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 INLET FLOW (GPM) 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V17 VALVES INLET JOYSTICK HANDLES FOR SERIES “20” A typical handle to spool movement pattern is shown. Different patterns are also available. The Joystick handle can be used ZLWKVWDQGDUGWKUHHSRVLWLRQVSRROVRUZLWKIRXUSRVLWLRQÁRDW spools. If work port reliefs are required on the joystick end of a VHFWLRQWKHUHOLHIFDUWULGJHVPXVWEHWKHVKLPDGMXVWDEOHW\SH When two joysticks are installed on the same valve assembly, it is recommended that there be two standard section between them to prevent handle interference. This is a special handle for the SERIES 20 stack valve that allows the spools of two adjacent sections to be operated by one common handle. The spools can be operated independently or VLPXOWDQHRXVO\GHSHQGLQJRQKDQGOHPRYHPHQW7KHRSWLRQLV W\SLFDOO\XVHGRQVSULQJFHQWHUWRQHXWUDOVHFWLRQV1RUPDOO\WKH handle is installed at the factory on sections ordered with handle RSWLRQ+RZHYHUWKHKDQGOHFDQDOVREHLQVWDOOHGLQWKHÀHOGRQ YDOYHVRULJLQDOO\HTXLSSHGZLWKVWDQGDUGKDQGOHVKDQGOHRSWLRQV WKURXJK7KLVGUDZLQJVKRZVWZRMR\VWLFNVZLWKRIIVHWKDQGOHV installed on a six section valve. :KHQRUGHULQJDYDOYHDVVHPEO\SOHDVHUHIHUWRWKHIROORZLQJ part numbers and indicate which sections the handle is to be installed on. The part numbers refer to the complete joystick assembly required to control two valve sections. Use the same SDUWQXPEHUVWRRUGHUNLWVIRUÀHOGLQVWDOODWLRQ JOYSTICK ASSEMBLY W/ STRAIGHT HANDLE: ASSEMBLED ON VALVE ............................ 20JS KIT ...................................................... JOYSTICK ASSEMBLY W/ OFFSET HANDLE: ASSEMBLED ON VALVE ............................ 20JO KIT ...................................................... SERIES 20 SOLENOID OPERATED WORK SECTIONS VALVES 7KHVROHQRLGRSHUDWHG6HULHVZRUNVHFWLRQVDOORZUHPRWHHOHFWULFDORQRIIFRQWURORUGHSHQGLQJRQWKHPRGHOPDQXDO FRQWURO7KHVROHQRLGRSHUDWHGVHFWLRQVFRQWDLQWZRZD\SRVLWLRQVFUHZLQVW\OHFDUWULGJHYDOYHV7KHVFUHZLQ FDUWULGJHVSURYLGHDUREXVWSODWIRUPIRUWKHKLJKHUWDQNSUHVVXUHVRIWHQVHHQLQPRELOHDSSOLFDWLRQV 3ULQFHVROHQRLGRSHUDWHGYDOYHVDUHSLORWRSHUDWHGYDOYHVZKHUHSLORWSUHVVXUHLVXVHGWRVKLIWWKHVSRRO'HSHQGLQJ on the model, the pilot pressure will be applied either directly to the end of the spool or to a piston that is connected WRWKHVSRRO:KHQERWKVROHQRLGVDUHGHHQHUJL]HGERWKVSRROHQGFDYLWLHVRUSLVWRQFDYLWLHVDUHFRQQHFWHGWRWDQN :KHQWKH´$µVROHQRLGLVHQHUJL]HGSLORWSUHVVXUHLVDSSOLHGWRWKH´$µHQGRIWKHVSRROSLVWRQFDXVLQJWKHVSRROWR VKLIWDJDLQVWVSULQJELDVDQGDOORZÁRZWRWKH´$µZRUNSRUW(QHUJL]LQJWKH´%µVROHQRLGFDXVHVVLPLODUDFWLRQRQWKH ´%µHQG,QWHUQDOSLORWSDVVDJHZD\VFRQYH\SLORWSUHVVXUHWRWKHVROHQRLGDFWXDWRUV Pilot pressure is typically supplied by a utility section, but in the case of load sense sections or closed center assemblies, LWFDQDOVREHSURYLGHGE\DQLQOHWPDQLIROGZKLFKFDQEHSURYLGHGZLWKÀOWHUHGSLORWÁRZ,IDXWLOLW\VHFWLRQLVXVHGLW must be installed between the last work section and the outlet cover. The utility section, or inlet manifold, limit the pilot pressure to approximately 350 psi. )RU DQ RSHQ FHQWHU V\VWHP D SUHVVXUH EXLOG XS FDUWULGJH LV QHHGHG LQ WKH XWLOLW\ VHFWLRQ 7KH SUHVVXUH EXLOG XS section provides pilot pressure to initiate the spool shift. A minimum of approximately 300 psi load induced pressure is UHTXLUHGWRFRPSOHWHWKHVSRROVKLIWDQGKROGWKHVSRROLQWKHVKLIWHGSRVLWLRQ)RURYHUFHQWHURUOLJKWORDGDSSOLFDWLRQV a restrictor installed in the work port line may be required. Manual sections used in the same assembly with solenoid VHFWLRQVPXVWHLWKHUEHXSVWUHDPRIVROHQRLGVHFWLRQVRUEHFXVWRPVHFWLRQVPDFKLQHGZLWKSLORWSDVVDJHZD\VLQDQ DVVHPEO\XVLQJDXWLOLW\VHFWLRQ,QDVVHPEOLHVZLWKDQLQOHWPDQLIROGERWKVROHQRLGDQGPDQXDOVHFWLRQVFDQEHLQWKH VDPHDVVHPEO\EXWPDQXDOVHFWLRQVPD\KDYHWREHPDFKLQHGZLWKSLORWSDVVWKURXJKSDVVDJHZD\V)RUVROHQRLG RSHUDWHGVHULHVVHFWLRQVDWDQGHPVHFWLRQZLWKSLORWSDVVWKURXJKSDVVDJHZD\VPXVWEHEHWZHHQWKHVHULHVVHFWLRQ and the utility section. Consult your sales representative for your application. 3ULFHVROHQRLGRSHUDWRUVDUHRIIHUHGLQERWKDGLYLGHGGHVLJQDVROHQRLGRQHDFKHQGRIWKHVHFWLRQDQGDFRPELQHG GHVLJQERWKVROHQRLGVRQWKHHQGRSSRVLWHWKHKDQGOH:HDOVRFXUUHQWO\RIIHUPRGHOVLQERWKWKUHDGVL]HDQG WKUHDGVL]HVROHQRLGFDUWULGJHV7KHWKUHDGVL]HRIIHUVDPRUHFRPSDFWDVVHPEO\DQGDPRUHHFRQRPLFDOFKRLFH as compared to a 10 thread size. V18 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 18-03-16-04 SERIES 20 (8 SERIES) COMBINED SOLENOID OPERATORS (BOTH OPERATORS ON ONE END) $6HULHVVROHQRLGRSHUDWHGVHFWLRQZLWKDKDQGOHFRGHRIRUZLOOGHVLJQDWHDFRPELQHGFRQÀJXUDWLRQZLWK ERWKVROHQRLGFDUWULGJHVRQRQHHQGRSSRVLWHWKHKDQGOHHQGRIWKHVHFWLRQ7KHFRPELQHGRSHUDWRUFRQÀJXUDWLRQV SURYLGHIRUHLWKHUHOHFWULFRUPDQXDORSHUDWLRQ+DQGOHFRQÀJXUDWLRQVZLOOEHWKHVDPHDVWKHVWDQGDUGPDQXDOVHFWLRQV $´&µSUHÀ[RQWKHVROHQRLGDQGFRLOGHVLJQDWLRQZLOOGHVLJQDWHDQVHULHVGHVLJQDQGZLOOKDYHVFUHZLQVROHQRLGFDUWULGJHV ZLWKDWKUHDGVL]H7KHVL]HFDUWULGJHVDOORZIRUDPRUHFRPSDFWVHFWLRQVL]H$QRSWLRQDOPDQXDORYHUULGHIHDWXUH LVDYDLODEOHIRUWKHVROHQRLGFDUWULGJHV&DUWULGJHVDQGFRLOVRQWKHVHULHVDUHQRWLQWHUFKDQJHDEOHZLWKWKH3ULQFH 10 series solenoid sections or sections manufactured prior to November 2014. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince Series 20 solenoid operated work sections may be used in any combination within a stack valve assembly. 8 SERIES SOLENOID OPERATED WORK SECTION 20PXXXXXX-CXXX COIL VOLTAGE & TERMINATION * 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 '9'&,QWHJUDO'HXWVFK 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 '9'&,QWHJUDO'HXWVFK 11H, 120 VAC DIN 43650 WORK SECTION TYPE P - Standard Parallel LP - Load Sense LPC - Load Sense Pressure Compensated S - Series (Use Spool Type N or P) PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) SOLENOID OPERATION &6WDQGDUG6ROHQRLG&DUWULGJH &06ROHQRLG&DUWULGJHZ0DQXDO2YHUULGH SPOOL TYPE A - 3 - Way 3-Position B - 4 - Way 3-Position C - 4 - Way 3-Position Free Flow Motor E - 3 - Way 3-Position Free Flow Motor H - 3 - Way 3-Position 20LP Only J - 4 - Way 3-Position 20LP Only K - 4 - Way 3-Position Free Flow Motor - 20 LP Only N - 4 - Way 3-Position Series P - 4 - Way 3-Position Series Motor J05 - 5 GPM Pressure Comp (LPC Only) J10 - 10 GPM Pressure Comp (LPC Only) J15 - 15 GPM Pressure Comp (LPC Only) PORT RELIEF “B” OPTION PORT RELIEF “A” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 SPOOL ACTION $6SULQJ&HQWHU 1RWH:RUNSRUWUHOLHIFDUWULGJHVRQWKH/3&DQG6DUH GLIIHUHQWWKDQWKHVWDQGDUG6HULHV3FDUWULGJH HANDLE OPTION 1. Standard Lever Handle 2. Less Handle Only VALVES $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 3. Less Complete Handle 4. Vertical Lever Handle 6HHSDJH9IRUFRLOGHWDLOV SERIES 20 (8 SERIES) TYPE C - SOLENOID OR MANUAL WORK SECTION DIMENSIONS SOLENOID OPERATED PRESSURE BUILD-UP VALVE UTILITY OPTION 20UE12F UTILITY OUTLET SECTION G PILOT 20U1 UTILITY SECTION WITH STD. OUTLET SECTION OTHER UTILITY & OUTLET SECTION OPTIONS ARE AVAILABLE “B” SOLENOID “A” SOLENOID “B” WORK PORT “A” WORK PORT IN 5.8 1.75 10.22 TANK 12.97 14.67 CATV 19-03-16-05 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11, 12, 13 & 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 SERIES 20 (8 SERIES) DIVIDED SOLENOID OPERATORS (OPERATORS ON BOTH ENDS) $6HULHVVROHQRLGRSHUDWHGVHFWLRQZLWKDKDQGOHFRGHRIRUZLOOGHVLJQDWHDVSOLWFRQÀJXUDWLRQZLWKDVROHQRLG FDUWULGJHRQHDFKHQGRIWKHVHFWLRQ+DQGOHRSWLRQSURYLGHVHOHFWULFRSHUDWLRQRQO\+DQGOHRSWLRQSURYLGHVDOHYHU handle for either electric or manual operation. $´'µSUHÀ[RQWKHVROHQRLGDQGFRLOGHVLJQDWLRQZLOOGHVLJQDWHDQVHULHVGHVLJQDQGZLOOKDYHVFUHZLQVROHQRLGFDUWULGJHV ZLWKDWKUHDGVL]H7KHVL]HFDUWULGJHVDOORZIRUDPRUHFRPSDFWVHFWLRQVL]H$QRSWLRQDOPDQXDORYHUULGHIHDWXUH LVDYDLODEOHIRUWKHVROHQRLGFDUWULGJHV&DUWULGJHVDQGFRLOVRQWKHVHULHVDUHQRWLQWHUFKDQJHDEOHZLWKWKH3ULQFH 10 series solenoid sections or sections manufactured prior to November 2014. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince Series 20 solenoid operated work sections may be used in any combination within a stack valve assembly. 8 SERIES SOLENOID OPERATED WORK SECTION 20PXXXXXX-DXXX COIL VOLTAGE & TERMINATION * 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 '9'&,QWHJUDO'HXWVFK 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 '9'&,QWHJUDO'HXWVFK 11H, 120 VAC DIN 43650 WORK SECTION TYPE P - Standard Parallel LP - Load Sense LPC - Load Sense Pressure Compensated S - Series (Use Spool Type N or P) PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) SOLENOID OPERATION '6WDQGDUG6ROHQRLG&DUWULGJH '06ROHQRLG&DUWULGJHZ0DQXDO2YHUULGH SPOOL TYPE PORT RELIEF “B” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 PORT RELIEF “A” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 SPOOL ACTION $6SULQJ&HQWHU HANDLE OPTION 5. Solenoid Operated Only (No Lever) 6. Solenoid Operated With Manual Lever 1RWH:RUNSRUWUHOLHIFDUWULGJHVRQWKH/3&DQG6DUH GLIIHUHQWWKDQWKHVWDQGDUG6HULHV3FDUWULGJH 6HHSDJH9IRUFRLOGHWDLOV SERIES 20 (8 SERIES) TYPE D & DP - SOLENOID OR MANUAL WORK SECTION DIMENSIONS 20UE12F UTILITY OUTLET SECTION SOLENOID OPERATED PRESSURE BUILD-UP VALVE UTILITY OPTION G PILOT 20U1 UTILITY SECTION WITH STD. OUTLET SECTION OTHER UTILITY & OUTLET SECTION OPTIONS ARE AVAILABLE “A” SOLENOID “A” WORK PORT “B” SOLENOID “B” WORK PORT 7.90 IN 1.75 9 6.43 TANK C-917 VALVES A - 3 - Way 3-Position B - 4 - Way 3-Position C - 4 - Way 3-Position Free Flow Motor H - 3 - Way 3-Position - 20LP Only J - 4 - Way 3-Position - 20LP Only K - 4 - Way 3-Position Free Flow Motor - 20LP Only N - 4 - Way 3-Position Series P - 4 - Way 3-Position Series Motor J05 - 5 GPM Pressure Comp (LPC Only) J10 - 10 GPM Pressure Comp (LPC Only) J15 - 15 GPM Pressure Comp (LPC Only) 5.97 5.92 (D) 6.41 (DP) 12.86 HANDLE OPTION 5 15.49 HANDLE OPTION 6 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11, 12, 13 & 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 19.1-03-16-02 SERIES 20 (10 SERIES) COMBINED SOLENOID OPERATORS (BOTH OPERATORS ON ONE END) A Series 20 solenoid operated section with a handle code of RU ZLOO GHVLJQDWH D FRPELQHG FRQILJXUDWLRQ ZLWK ERWKVROHQRLGFDUWULGJHVRQRQH end, opposite the handle end of the section. The combined RSHUDWRUFRQÀJXUDWLRQVSURYLGH for either electric or manual RSHUDWLRQ+DQGOHFRQÀJXUDWLRQV will be the same as the standard manual sections. 20UE12F UTILITY OUTLET SECTION OTHER UTILITY & OUTLET SECTION OPTIONS ARE AVAILABLE G PILOT ‘B’ SOLENOID ‘A’ SOLENOID $Q´6µSUHÀ[RQWKHVROHQRLGDQG FRLOGHVLJQDWLRQZLOOGHVLJQDWHD VHULHVGHVLJQDQGZLOOKDYH VFUHZLQVROHQRLGFDUWULGJHVZLWK D WKUHDG VL]H &DUWULGJHV and coils on the 10 series will EH LQWHUFKDQJHDEOH ZLWK WKH components on Prince solenoid operated valves manufactured prior to November 2014 as well as current production 10 series valves. The 10 series sections will have a dimensional envelope the same as Prince solenoid operated sections manufactured prior to November, 2014. ‘A’ WORK PORT ‘B’ WORK PORT 8.85 TANK C-6 34 IN IN 10.62 13.37 15.06 C-6 3 4 VALVES 10 SERIES SOLENOID OPERATED WORK SECTION 20PXXXXXX-SXXX WORK SECTION TYPE P - Standard Parallel LP - Load Sense LPC - Load Sense Pressure Compensated S - Series (Use Spool Type N or P) PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) A - 3 - Way 3-Position B - 4 - Way 3-Position C - 4 - Way 3-Position Free Flow Motor E - 3 - Way 3-Position Free Flow Motor H - 3 - Way 3-Position 20LP Only J - 4 - Way 3-Position 20LP Only K - 4 - Way 3-Position Free Flow Motor - 20 LP Only N - 4 - Way 3-Position Series P - 4 - Way 3-Position Series Motor J05 - 5 GPM Pressure Comp (LPC Only) J10 - 10 GPM Pressure Comp (LPC Only) J15 - 15 GPM Pressure Comp (LPC Only) SPOOL ACTION V20 $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 PORT RELIEF “A” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 1RWH:RUNSRUWUHOLHIFDUWULGJHVRQWKH/3&DQG6DUH GLIIHUHQWWKDQWKHVWDQGDUG6HULHV3FDUWULGJH $6SULQJ&HQWHU 1. Standard Lever Handle 2. Less Handle Only 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11H, 120 VAC DIN 43650 PORT RELIEF “B” OPTION SPOOL TYPE HANDLE OPTION COIL VOLTAGE & TERMINATION * 3. Less Complete Handle 4. Vertical Lever Handle 6HHSDJH9IRUFRLOGHWDLOV 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 12, 13 & 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 20-03-16-05 SERIES 20 (10 SERIES) SPLIT SOLENOID OPERATORS (OPERATORS ON BOTH ENDS) SPECIFICATIONS: 6(&7,216 20 GPM INTERNAL PILOT INTERNAL DRAIN 20UE12F UTILITY OUTLET SECTION OTHER UTILITY & OUTLET SECTION OPTIONS ARE AVAILABLE An “S” prefix on the solenoid and coil GHVLJQDWLRQZLOOGHVLJQDWH D V H U L H V G H V L J Q and will have screw LQ VROHQRLG FDUWULGJHV with a #10 thread size. &DUWULGJHV DQG FRLOV on the 10 series will be LQWHUFKDQJHDEOHZLWKWKH components on Prince solenoid operated valves manufactured prior to November 2014 as well as current production 10 series valves. The 10 series sections will h a ve a d ime nsio n a l envelope the same as Prince solenoid operated sections manufactured prior to November, 2014. G PILOT ‘A’ SOLENOID ‘B’ SOLENOID ‘B’ WORK PORT ‘A’ WORK PORT IN TANK IN 6.44 1.75 10 SERIES SOLENOID OPERATED WORK SECTION 12.88 HANDLE OPTION 5 15.59 HANDLE OPTION 6 20PXXXXXX-SXXX COIL VOLTAGE & TERMINATION * 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11H, 120 VAC DIN 43650 WORK SECTION TYPE P - Standard Parallel LP - Load Sense LPC - Load Sense Pressure Compensated S - Series (Use Spool Type N or P) PORT SIZE 1. #10 SAE (7/8-14 THREAD) 2. #8 SAE (3/4-16 THREAD) 3. #12 SAE (1 1/16-12 THREAD) 4. 1/2 NPTF (2000 PSI MAX) SPOOL TYPE A - 3 - Way 3-Position B - 4 - Way 3-Position C - 4 - Way 3-Position Free Flow Motor H - 3 - Way 3-Position - 20LP Only J - 4 - Way 3-Position - 20LP Only K - 4 - Way 3-Position Free Flow Motor - 20LP Only N - 4 - Way 3-Position Series P - 4 - Way 3-Position Series Motor J05 - 5 GPM Pressure Comp (LPC Only) J10 - 10 GPM Pressure Comp (LPC Only) J15 - 15 GPM Pressure Comp (LPC Only) SPOOL ACTION $6SULQJ&HQWHU HANDLE OPTION 5. Solenoid Operated Only (No Lever) 6. Solenoid Operated With Manual Lever CATV 20.1-03-16-02 7.90 6.75 VALVES A Series 20 solenoid operated section with a handle code of 5 or ZLOO GHVLJQDWH D VSOLW FRQILJXUDWLRQ ZLWK D VROHQRLG FDUWULGJH RQ each end of the section. Handle option 5 provides electric operation only. Handle option 6 provides a lever handle for either electric or manual operation. PORT RELIEF “B” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 PORT RELIEF “A” OPTION $5HOLHI&DYLW\3OXJJHG B - Shim Adjustable Relief 500-1350 PSI Set at 1350 C - Shim Adjustable Relief 1351-1750 PSI Set at 1750 D - Shim Adjustable Relief 1751-2200 PSI Set at 2200 E - Shim Adjustable Relief 2201-3000 PSI Set at 2500 1RWH:RUNSRUWUHOLHIFDUWULGJHVRQWKH/3&DQG6 DUHGLIIHUHQWWKDQWKHVWDQGDUG6HULHV3FDUWULGJH 6HHSDJH9IRUFRLOGHWDLOV 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11, 12, 13 & 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V20.1 SERIES 20 UTILITY SECTIONS (FOR USE WITH SOLENOID OPERATED SECTIONS) UTILITY SECTION 20UX - XXX UTILITY TYPE COIL VOLTAGE & TERMINATION* U - Standard Utility UTILITY OPTION 1. Solenoid On-Off Press. Build-Up Valve 2. Mechanical Continuous On Press. Build-up Valve 3. Closed Center Utility Section (Required with Load Sense Assembly) 4. Power Beyond Utility with #10 SAE Power Beyond Port * 5. External Pilot Supply Utility * Note: With Series 20 solenoid operator assemblies, the power beyond line is connected to the utility section and NOT to a power beyond port in the outlet section. COMBINATION OUTLET/UTILITY SECTION (omit for options 2 thru 5) 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 12D, 12 VDC Deutsch 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, VDC DIN 43650 24D, 24 VDC Deutsch 11C, 120 VAC Conduit 11H, 120 VAC DIN 43650 20UEXXX OUTLET PORT SIZE FILTER OPTIONS 1. #10 SAE ORB (7/8 – 14 UNF) A - Without Filter Element F - With Filter Element (Cavity is always present) PRESSURE BUILD-UP OPTIONS SERIES 20 COMBINATION UTILITY SECTION AND OUTLET Incorporates both the utility and outlet sections into one mainfold. For use in solenoid operatied assemblies (either on/off or proportional). 3URYLGHVUHGXFLQJFDUWULGJHSVLOLPLWVSUHVVXUHWRVROHQRLGV Mechanical pressure build-up (open center or PBY), or closed center. 2SWLRQDOÀOWUDWLRQRISLORWÁRZ ** 0HGLXPSUHVVXUHEXLOGXSVFDQEHFRQVLGHUHGIRUKLJKHUÁRZSURSRUWLRQDO applications. *** Build-up option 7 requires pilot pressure to be provided by downstream function. SERIES 20 SYMBOL SCHEMATIC OF A SOLENOID OPERATOR ASSEMBLY B OUT A IN SOL A SOL B VALVES 2. Mechanical Pressure Build-Up 3. Closed Center 4. Mech. Pressure Build-Up; #12 SAE ORB Power Beyond 5. Mech. Pressure Build-Up, Medium Pressure; #12 SAE Power Beyond** 6. Mech. Pressure Build-Up, Medium Pressure** 7. #12 SAE ORB Power Beyond (No Pressure Build-Up)*** PRESSURE REDUCING CARTRIDGE PRESSURE BUILD-UP CARTRIDGE OUT 20I2J 20U1 20P1BA1GG–C12Q / 20P1BA6GG–D12Q OR 20P1BA1GG–S12Q / 20P1BA6GG–S12Q 20E21 PILOT GAUGE PRESSURE REDUCING CARTRIDGE PRESSURE BUILD-UP CARTRIDGE PRESSURE BUILD-UP PRESSURE REDUCING POWER BEYOND TANK 20UE14F V20.2 20U2 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 11, 12, 13 & 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 20.2-03-16-02 SERIES 20 PRESET RELIEF CARTRIDGES PRESET 20IR - OX - X X X X INLET Setting in PSI - Leave RELIEF CARTRIDGE Blank for Standard PRESET WORK PORT RELIEF CARTRIDGE CARTRIDGE CODE / STYLE B - SHIM ADJ 500-1350 PSI C - SHIM ADJ 1351-1750 PSI D - SHIM ADJ 1751-2200 PSI E - SHIM ADJ 2201-3000 PSI F - SCREW ADJ 500-1350 PSI G - SCREW ADJ 1351-1750 PSI H - SCREW ADJ 1751-2200 PSI J - SCREW ADJ 2201-3000 PSI K - SCREW ADJ 3001-3500 PSI CARTRIDGE CODE / STYLE B - SHIM ADJ 500-1350 PSI C - SHIM ADJ 1351-1750 PSI D - SHIM ADJ 1751-2200 PSI E - SHIM ADJ 2201-3000 PSI F - SCREW ADJ 500-1350 PSI G - SCREW ADJ 1351-1750 PSI H - SCREW ADJ 1751-2200 PSI J - SCREW ADJ 2201-3000 PSI L - ANTI-CAV/SHIM RELIEF 500-1350 PSI M - ANTI-CAV/SHIM RELIEF 1351-1750 PSI N - ANTI-CAV/SHIM RELIEF 1751-2200 PSI R - ANTI-CAV/SHIM RELIEF 2201-3000 PSI S - ANTI-CAV/SCREW RELIEF 500-1350 PSI T - ANTI-CAV/SCREW RELIEF 1351-1750 PSI W - ANTI-CAV/SCREW RELIEF 1751-2200 PSI Y - ANTI-CAV/SCREW RELIEF 2201-3000 PSI Setting in PSI - Leave Blank for Standard STD SETTING 1350 PSI @ 3 GPM 1750 PSI @ 3 GPM 2200 PSI @ 3 GPM 2500 PSI @ 3 GPM 1350 PSI @ 3 GPM 1750 PSI @ 3 GPM 2200 PSI @ 3 GPM 2500 PSI @ 3 GPM 1350 PSI @ 3 GPM 1750 PSI @ 3 GPM 2200 PSI @ 3 GPM 2500 PSI @ 3 GPM 1350 PSI @ 3 GPM 1750 PSI @ 3 GPM 2200 PSI @ 3 GPM 2500 PSI @ 3 GPM VALVES STD SETTING 1350 PSI @ 10 GPM 1750 PSI @ 10 GPM 2200 PSI @ 10 GPM 2500 PSI @ 10 GPM 1350 PSI @ 10 GPM 1750 PSI @ 10 GPM 2200 PSI @ 10 GPM 2500 PSI @ 10 GPM 3250 PSI @ 10 GPM 20PR - OX - X X X X CATV 20.3-03-16-01 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 19 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V20.3 Directional Control Valves VALVES SECTIONAL BODY Model SV STANDARD FEATURES 6HFWLRQV3HU9DOYH%DQN /RDG&KHFNV2Q(DFK6HFWLRQ +DUG&KURPH3ODWHG6SRROV &RPSDFW&RQVWUXFWLRQ (QKDQFHG0HWHULQJ6HFWLRQ$YDLODEOHLQ ERWKWKH+LJKDQG/RZ6HFWLRQV 'LIIHUHQWLDO3RSSHW6W\OH5HOLHI$GMXVWDEOH IURPWRSVL$OVRDYDLODEOHLQ/RZ3UHVVXUH 9HUVLRQ$GMXVWDEOHIURPWRSVL 3RZHU%H\RQG&DSDELOLW\ 5HYHUVLEOH+DQGOH 0LG,QOHWDQG/RFN9DOYH6HFWLRQDYDLODEOH )ORZ&RQWURO,QOHW SPECIFICATIONS Parallel or Series Circuit Construction Pressure Rating 0D[LPXP2SHUDWLQJ3UHVVXUH ........ SVL 0D[LPXP7DQN3UHVVXUH................... SVL Nominal Flow Rating ...........................*30 5HIHUWR3UHVVXUH'URS&XUYHV Filtration:)RUJHQHUDOSXUSRVHYDOYHVÁXLG FOHDQOLQHVVVKRXOGPHHWWKH,62 OHYHO)RUH[WHQGHGOLIHRUIRUSLORWRSHUDWHGYDOYHV WKHÁXLGFOHDQOLQHVVOHYHOLVUHFRPPHQGHG CATV 21-07-13-02 Foot Mounting Maximum Operating Temp. ..........................) Weight Per Section ,QOHW6HFWLRQ .................................... $SSUR[,EV 2XWOHW6HFWLRQ ................................ $SSUR[,EV :RUN6HFWLRQ6WDQGDUG ............... $SSUR[,EV :RUN6HFWLRQ+LJK ...................... $SSUR[,EV 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 ORDERING INFORMATION: The following is a listing of valve sections available from stock on a standard basis. STANDARD SECTIONS AVAILABLE: INLET SECTIONS ALL HAVE BOTH TOP AND SIDE INLET PORTS PART NO. RELIEF TYPE AND SETTING PORT SIZE SVI21 SVI24 SVI15 SVI25 No Relief Adjustable Low Pressure Relief Set at 1000 PSI Adjustable High Pressure Relief Set At 2000 PSI Adjustable High Pressure Relief Set at 2000 PSI #10 SAE ORB (7/8-14 THD) #10 SAE ORB (7/8-14 THD) #8 SAE ORB (3/4-16 THD) #10 SAE ORB (7/8-14 THD) WORK SECTIONS ALL HAVE #8 SAE ORB (3/4-16 THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE PART NO. SPOOL TYPE AND ACTION SVW1AA1 SVW1BA1 SVW1BB1 SVW1CA1 SVW1CB1 SVW1DD1 SVL1CA1 SVM1ES1 3-Way Single Acting w/ Spring Center 4-Way Double Acting w/ Spring Center (Work Ports Blocked in Neutral) 4-Way Double Acting w/ 3 Position Detent (Work Ports Blocked in Neutral) 4-Way Motor Spool w/ Spring Center (Work Ports Open to Tank in Neutral 4-Way Motor Spool w/ 3 Position Detent (Work Ports Open to Tank in Neutral) 4-Way 4 Position Float w/ Spring Center and Float Detent 4-Way Spool w/ Spring Center (with Pilot Operated Checks on Both Work Ports) 4-Way Meter Spool w/ Spring Center (Work Ports Blocked in Neutral) PORT RELIEF WORK SECTIONS ALL HAVE #8 SAE ORB (3/4-16 THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE. MODELS WITH RELIEF FACTORY SET AT 2000 PSI AT 3 GPM. PART NO. SPOOL TYPE AND ACTION PORT RELIEFS SVH1BA1AA SVH1BA1GG SVH1DD1AA SVH1DD1BB SVR1ES1AA SVR1ES1GG SVS1GA1GG SVS1GA1AA 4-Way Double Acting w/ Spring Center 4-Way Double Acting w/ Spring Center 4-Way 4 Position Float w/ Spring Center and Float Detent 4-Way 4 Position Float w/ Spring Center and Float Detent 4-Way Meter Spool w/ Spring Center 4-Way Meter Spool w/ Spring Center 4-Way Double Acting Series w/ Spring Center 4-Way Double Acting Series w/ Spring Center Port Relief Plugged Adjustable 1500-3000 PSI Port Relief Plugged Shim Adjustable 1500-3000 PSI Port Relief Plugged Adjustable 1500-3000 PSI Adjustable 1500-3000 PSI Port Relief Plugged OUTLET SECTIONS ALL HAVE BOTH TOP AND SIDE OUTLET PORTS VALVES PART NO. EXHAUST OPTIONS PORT SIZE SVE11 SVE21 SVE22 SVE23 SVE26 SVE27 Open Center Outlet w/ Conversion Plug Open Center Outlet w/ Conversion Plug Power Beyond Outlet w/ #8 SAE Beyond Port Closed Center Outlet Open Center Outlet Pressure Build-up Valve Power Beyond Pressure Build-up Valve #8 SAE ORB (3/4-16 THD) #10 SAE ORB (7/8-14 THD) #10 SAE ORB (7/8-14 THD) #10 SAE ORB (7/8-14 THD) #10 SAE ORB (7/8-14 THD) #10 SAE ORB (7/8-14 THD) TIE ROD KITS TIE ROD TORQUE 150in-lbs ± 6in-lbs (12 1/2 ft-lbs ±1/2) PART NO. PART NO. 660401001 1 Section* 660401002 2 Sections* 660401003 3 Sections* 660401004 4 Sections* 660401005 5 Sections* *Number of Work Sections 660401006 660401007 660401008 660401009 660401010 6 Sections* 7 Sections* 8 Sections* 9 Sections* 10 Sections* SPECIAL INLET AND OUTLET SECTIONS AVAILABLE: Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales 5HSUHVHQWDWLYHZLWK\RXUVSHFL¿FUHTXLUHPHQWVDQGDPRGHOQXPEHUZLOOEHDVVLJQHGIRU\RX7KLVPRGHOQXPEHUFDQEHXVHGIRUIXWXUH orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. INLET SECTIONS SVIXX-XXXX PORT SIZE 6$(25%7+' 6$(25%7+' $OOLQOHWVHFWLRQVKDYH WRSDQGVLGHLQOHWV RELIEF SETTING (in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ÀHGZLWKHDFKRUGHU$QDVVHPEO\QXPEHUZLOOEHDVVLJQHGDWWKHWLPHRIWKHRUGHU7KLVDVVHPEO\QXPEHUFDQWKHQEHXVHGIRUIXWXUH RUGHUV ASSEMBLY MODEL NUMBER SVA-XXXX ;;;; 6HTXHQFHRI1XPEHUV7KLVQXPEHUZLOOEHDVVLJQHGWRÀQDOYDOYHWREHDVVHPEOHGDQGWHVWHGDWWKHIDFWRU\(DFKQHZRUGHURUTXRWHZLOO EHDVVLJQHGDQHZDVVHPEO\PRGHOQXPEHU3OHDVHXVHTXRWDWLRQVKHHWDWWKHHQGRI69VHFWLRQ 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 14 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 22-07-13-02 SPECIAL WORK SECTIONS AVAILABLE: WORK SECTIONS Work Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales Representative with your VSHFL¿FUHTXLUHPHQWVDQGDPRGHOQXPEHUZLOOEHDVVLJQHGIRU\RX7KLV model number can be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. SVXXXXX :6WG:RUN6HFWLRQ 00HWHULQJ:RUN6HFWLRQ /:RUN6HFWLRQZLWK'RXEOH32&KHFNV ))LQH0HWHULQJ3 6$(25%7+' 6$(25%7+' $:D\3RVLWLRQ %:D\3RVLWLRQ &:D\3RVLWLRQ0RWRU ':D\3RVLWLRQ)ORDW (:D\3RVLWLRQ0HWHULQJ690RQO\ ):D\3RVLWLRQ0HWHULQJ690RQO\ -:D\3RVLWLRQ)LQH0HWHULQJ69)RQO\ .:D\3RVLWLRQ&RXQWHUEDODQFH'UDLQ69: 0:D\3RVLWLRQ&RXQWHUEDODQFH'UDLQ0RWRU690 /RFN9DOYH6HFWLRQDYDLODEOHRQO\ZLWK6SRRO2SWLRQ& 0HWHULQJ6HFWLRQDYDLODEOHRQO\ZLWK6SRRO2SWLRQV(RU) )LQH0HWHULQJDYDLODEOHRQO\ZLWK6SRRO2SWLRQV- PORT SIZE SPOOL TYPE PORT RELIEF WORK SECTIONS SVXXXXXXX SECTION TYPE +3RUW5HOLHI6HFWLRQ 53RUW5HOLHI0HWHULQJ6HFWLRQ 66HULHV&LUFXLW3RUW5HOLHI6HFWLRQ *3RUW5HOLHI)LQH0HWHULQJ6HFWLRQ3 6$(25%7+' 6$(25%7+' $:D\3RVLWLRQ %:D\3RVLWLRQ &:D\3RVLWLRQ0RWRU ':D\3RVLWLRQ)ORDW (:D\3RVLWLRQ0HWHULQJ695RQO\ ):D\3RVLWLRQ0HWHULQJ695RQO\ *:D\3RVLWLRQ6HULHV696RQO\ +:D\3RVLWLRQ0RWRU6HULHV696RQO\ -:D\3RVLWLRQ)LQH0HWHULQJ69*RQO\ .:D\3RVLWLRQ&RXQWHUEDODQFH'UDLQ69+ 0:D\3RVLWLRQ&RXQWHUEDODQFH'UDLQ0RWRU695 $6SULQJ&HQWHU69+696RQO\ %3RVLWLRQ'HWHQW &)ULFWLRQ'HWHQW '6SULQJ&HQWHUZ)ORDW'HWHQW69+RQO\ (/LJKW6SULQJ&HQWHU )3RVLWLRQ'HWHQW1HXWUDODQG2XW1R,Q3RVLWLRQ *3RVLWLRQ1HXWUDODQG2XW6SULQJ2IIVHWWR2XW +3RVLWLRQ1HXWUDODQG,Q6SULQJ2IIVHWWR,Q -6&ZLWK0LFUR6ZLWFK%UDFNHW3RVLWLRQ .6&ZLWK0LFUR6ZLWFK%UDFNHW3RVLWLRQ 06SULQJ&HQWHU'HWHQW,Q 16SULQJ&HQWHU'HWHQW2XW 56SULQJ&HQWHU3QHXPDWLF$FWXDWRU 66SULQJ&HQWHU69569* 0LFUR6ZLWFKQRWSURYLGHG PORT SIZE SPOOL TYPE SPOOL ACTION HANDLE OPTION 6WDQGDUG/HYHU+DQGOH /HVV+DQGOH2QO\ /HVV&RPSOHWH+DQGOH$VVHPEO\ $GMXVWDEOH+DQGOH 7DQJ6SRRO(QG2QO\ &OHYLV6SRRO(QG2QO\ 9HUWLFDO+DQGOH %ODQNIRU2SWLRQDO-R\VWLFN+DQGOH ([WHQGHG(QFORVHG+DQGOH HANDLE OPTION 6WDQGDUG/HYHU+DQGOH /HVV+DQGOH2QO\ /HVV&RPSOHWH+DQGOH$VVHPEO\ $GMXVWDEOH+DQGOH 7DQJ6SRRO(QG2QO\ &OHYLV6SRRO(QG2QO\ 9HUWLFDO+DQGOH 6WUDLJKW+DQGOH %ODQNIRU2SWLRQDO-R\VWLFN+DQGOH (QFORVHG+DQGOH ([WHQGHG(QFORVHG+DQGOH /RFNLQJ+DQGOH SPOOL ACTION $6SULQJ&HQWHU69:69/RQO\ %3RVLWLRQ'HWHQW &)ULFWLRQ'HWHQW '6SULQJ&HQWHUZ)ORDW'HWHQW69:RQO\ (/LJKW6SULQJ&HQWHU )3RVLWLRQ'HWHQW1HXWUDODQG2XW1R,13RVLWLRQ *3RVLWLRQ&HQWHUDQG6SRRO2XW6SULQJ/RDGHG WR6SRRO2XW3UHVVXUHWR%3RUW3RVLWLRQ +3RVLWLRQ&HQWHUDQG6SRROOQ6SULQJ/RDGHG WR6SRRO,Q3UHVVXUHWR$3RUW3RVLWLRQ -6&ZLWK0LFUR6ZLWFK%UDFNHW3RVLWLRQ0LFUR6ZLWFKQRWSURYLGHG .6&ZLWK0LFUR6ZLWFK%UDFNHW3RVLWLRQ0LFUR6ZLWFKQRWSURYLGHG DFWLYDWHVRQVSRRORXWRQO\ 06SULQJ&HQWHU'HWHQW,Q 16SULQJ&HQWHU'HWHQW2XW 56SULQJ&HQWHU3QHXPDWLF$FWXDWRU 66SULQJ&HQWHU69069) PORT RELIEF “B” OPTION $5HOLHI&DYLW\3OXJJHG %1RQ$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, &1RQ$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, '$QWL&DYLWDWLRQ&KHFN ($GMXVWDEOH&RPELQDWLRQ3RUW5HOLHI$QWL&DYLWDWLRQ&KHFN 36, )1RQ$GMXVWDEOH&RPELQDWLRQ3RUW5HOLHI$QWL&DYLWDWLRQ &KHFN36, *$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, +$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, PORT RELIEF “A” OPTION $5HOLHI&DYLW\3OXJJHG %1RQ$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, &1RQ$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, '$QWL&DYLWDWLRQ&KHFN ($GMXVWDEOH&RPELQDWLRQ3RUW5HOLHI$QWL&DYLWDWLRQ&KHFN 36, )1RQ$GMXVWDEOH&RPELQDWLRQ3RUW5HOLHI$QWL&DYLWDWLRQ &KHFN36, *$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, +$GMXVWDEOH'LUHFW$FWLQJ5HOLHI36, &DQQRWEHXVHGRQZRUNVHFWLRQVZLWKÁRDWRSWLRQGXHWR LQWHUIHUHQFHZLWKKDQGOH 'RQRWXVHLQDSSOLFDWLRQVWKDWUHTXLUHORZZRUNSRUWOHDNDJH 0D[DOORZDEOHOHDNDJHLQ3PLQ#SVL For Work Port Relief Settings Other Than Standard SVH1BA1GG-18-25 %32575(/,()35(6685(,1+81'5('6 (;$03/( 36,DW*30 $OO3RUW5HOLHIVVHWDW*30 $32575(/,()35(6685(,1+81'5('6 (;$03/( 36,DW*30 $OO3RUW5HOLHIVVHWDW*30 CUSTOM SECTION)RU2(0DSSOLFDWLRQFXVWRPVHFWLRQVFDQRIWHQEHGHVLJQHGWRPHHW\RXUVSHFLÀFDWLRQV6SHFLDOKDQGOHVVSRRODQG VSRRODFWLRQVDUHRIWHQHDVLO\PDGHEHFDXVHRIWKH69YDOYH·VÁH[LEOHGHVLJQ&RQVXOW\RXUVDOHVUHSUHVHQWDWLYHZLWK\RXUVSHFLÀFDWLRQV CATV 23-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 15 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES SECTION TYPE FIELD CONVERSION KITS, REPAIR KITS AND RELIEF CARTRIDGES SPOOL ATTACHMENT KITS 6SULQJ&HQWHU.LWH[FHSW690 3RVLWLRQ'HWHQW.LW )ULFWLRQ'HWHQW.LW )ORDW'HWHQW.LW 6SULQJ&HQWHU'HWHQW,Q 6SULQJ&HQWHU'HWHQW2XW 6&Z0LFUR6ZLWFK3RVLWLRQ 6&Z0LFUR6ZLWFK3RVLWLRQ HANDLE KITS 6WG+DQGOH.LW &OHYLV6XE$VV\ &RPSOHWH+DQGOH.LW 3LQ.LW 9HUWLFDO+DQGOH.LW 6WUDLJKW+DQGOH.LW &RPSOHWH$GMXVWDEOH+DQGOH.LW $GMXVWDEOH+DQGOH.LW -R\VWLFN+DQGOH.LW/HVV+DQGOH %UDFNHWRQO\0LFUR6ZLWFKLVQRWSURYLGHG SEAL KITS /RFNLQJ+DQGOH.LW %HQW-R\VWLFN+DQGOH.LW 6WUDLJKW-R\VWLFN+DQGOH.LW 2IIVHW-R\VWLFN+DQGOH.LW 69:6905HSODFHPHQW6HDO.LW ,QOHW6HDO.LW 2XWOHW6HDO.LW %HWZHHQ6HFWLRQ6HDO.LW 69+6955HSODFHPHQW6HDO.LW 69/5HSODFHPHQW6HDO.LW 6965HSODFHPHQW6HDO.LW $QWL&DYLWDWLRQ&KHFN $GM3RUW5HOLHI36, $GM3RUW5HOLHI36, 6+,0 6+,0 6+,0 6KLP$VVRUWPHQW INLET RELIEFS ,QOHW5HOLHI3OXJ $GM/RZ3UHVVXUH,QOHW5HOLHI $GM+LJK3UHVVXUH,QOHW5HOLHI OUTLET CARTRIDGES PORT RELIEFS 3RUW5HOLHI3OXJ 6KLP$GM3RUW5HOLHI36, 6KLP$GM3RUW5HOLHI36, $GM&RPELQDWLRQ3RUW 5HOLHI$QWL&DY&KHFN36, 6KLP$GM&RPELQDWLRQ3RUW 5HOLHI$QWL&DY&KHFN36, 2SHQ&HQWHU3OXJ 6$(3RZHU%H\RQG&DUW &ORVHG&HQWHU3OXJ 2SHQ&HQWHU%XLOG8S&DUW 3RZHU%H\RQG%XLOG8S&DUW MISC. KITS /RDG&KHFN.LW PERFORMANCE CURVES 6862,/$7Û) 6 200 5 150 4 3 2 1 100 50 4 6 8 10 12 14 3000 2500 2000 1500 1000 16 2 4 6 FLOW GPM 75 50 25 6 8 10 12 14 PRESSURE DROP PSI 1 100 4 10 12 14 16 PRESSURE DROP A OR B TO T 6 NO. OF WORK SECTIONS PRESSURE DROP PSI PRESSURE DROP P TO A OR B 2 8 FLOW GPM 100 6 4 75 2 50 25 16 2 4 FLOW GPM 6 8 10 12 14 NO. OF WORK SECTIONS 2 RELIEF VALVE CURVES PRESSURE (PSI) 250 NO. OF WORK SECTIONS VALVES PRESSURE DROP PSI PRESSURE DROP P TO T 16 FLOW GPM 6 100 75 3 50 1 25 4 9 6 8 10 12 FLOW GPM 14 16 PRESSURE DROP PSI PRESSURE DROP PSI 125 NO. OF WORK SECTIONS OPEN CENTER PRESSURE DROP P TO T 150 120 SUS OIL AT 100ÛF OPEN CENTER PRESSURE DROP P-A-B-T 300 6 250 3 200 1 150 100 50 4 6 8 10 12 FLOW GPM 14 NO. OF WORK SECTIONS SVS SERIES SECTION TEST DATA 16 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 24-07-13-02 DIMENSIONAL DATA WORK SECTIONS A WORK PORT B WORK PORT OUTLET COVER .25 TYP .75 PART NUMBER WILL BE STAMPED IN THIS LOCATION TYPICAL FLOAT OPTION 1.09 2.18 1.09 CONVERSION PLUG 1.67 SVW SPOOL TRAVEL .250 TO WORK TYP. .468 TO FLOAT TYP. 1.44 .72 TOP OUTLET 1.94 PART NUMBER WILL BE STAMPED IN THIS LOCATION 1.50 SIDE OUTLET 3.25 1.25 2.00 SVEXX 2.91 INLET COVER 1.55 5.34 1.63 1.75 1.88 1.44 .72 SVH/SVR/ SVG 1.50 .75 SIDE INLET 1.09 TOP INLET 3.00 PART NUMBER WILL BE STAMPED IN THIS LOCATION 4.66 3.25 2.00 1.50 5.34 3.56 SVIXX 1.75 1.75 .88 2.52 1.44 .72 SVL .31 4.32 BOTTOM VIEW OF MOUNTING DIMENSIONS 3.00 .81 3/8-16UNC THD 3 PLACES 3.88 4.66 .78 1.44 1.50 5.34 1.63 1.75 1.88 1.44 .72 SVS SEE CHART COLUMN A SEE CHART COLUMN B 3.00 4.66 .78 1.50 1.75 SPOOL TRAVEL .281 TO WORK TYP. 2.50 1.50 1.22 Number of Work Sections 5.34 SVM/SVF 1.44 .72 1.40 3.06 1.50 CATV 25-07-13-02 5.34 1.75 “A” “B*” :LWKSOXJLQLQOHWSRZHUEH\RQGLQRXWOHW 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 VALVES 1.50 TYPICAL STACK DIMENSIONAL DATA 12.50 7.44 2.00 5.58 2.00 SVEXX C-590 9.30 2.60 1.75 1.95 8.59 POWER BEYOND PORT 3.71 SIDE OUTLET TOP OUTLET SVE 1.47 SVL THE ROD TORQUE LQOEVLQOEV IWOEV 1.44 SVH\SVS 1.44 SVM SVW -S12L -T12Q 1.47 VALVES SVI 3.86 3.88 3.06 7.66 5.88 5.00 C-635 SVIXX ENCLOSED HANDLE, OPTIONS 11 AND 12 'XUDEOHGLHFDVWPHWDOKRXVLQJ:HDWKHUDQGRLOUHVLVWDQWUXEEHUERRW5HYHUVLEOHKDQGOHFDQEHPRXQWHGLQHLWKHUD YHUWLFDORUKRUL]RQWDOSRVLWLRQ7KHH[WHQGHGKDQGOHRSWLRQSURYLGHVWKHQHFHVVDU\FOHDUDQFHIRUZRUNSRUWUHOLHIDQG ORFNFDUWULGJHV7KHH[WHQGHGKDQGOHRSWLRQFDQDOVREHXVHGRQWKH69:DQG690ZRUNVHFWLRQVZKHQLWLVGHVLUHG WRNHHSKDQGOHVDOLJQHGLQDQDVVHPEO\ZLWKERWKORZDQGKLJKVHFWLRQV 2SWLRQHQFORVHGKDQGOHNLW 2SWLRQH[WHQGHGHQFORVHG KDQGOHNLW 12° KDQGOHNLWIRUHQFORVHG KDQGOHRSWLRQVKDQGOHNQRE KH[QXW KDQGOHNLWLVQRWLQFOXGHG LQWKH2SWLRQ RUNLWVDERYH 8.73 STANDARD SECTION SVIXX Handle option 11 (SVW & SVM) 9 23° Float position Alternate parallel handle position 12.03 10.21 PORT RELIEF SECTION SVIXX Handle option 12 (SVH, SVL, SVS & SVR) 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 26-07-13-02 PARALLEL CIRCUIT SVW, SVM, SVF, SVH, SVR, SVG AND SVL WORK SECTIONS 3DUDOOHOFLUFXLWVHFWLRQVDUHE\IDUWKHPRVWFRPPRQ7KH69:69069) OPEN CENTER PASSAGE 69+69569*DQG69/DUHDOORISDUDOOHOFLUFXLWFRQVWUXFWLRQ7KH\FDQ LOAD CHECK EHFRPELQHGWRJHWKHULQDQ\RUGHULQDQDVVHPEO\:KHQDQ\RQHRIWKH PARALLEL CIRCUIT CORE VSRROVLVVKLIWHGLWEORFNVRIIWKHRSHQFHQWHUSDVVDJHWKURXJKWKHYDOYH 7KHRLOWKHQÁRZVLQWRWKHSDUDOOHOFLUFXLWFRUHPDNLQJRLODYDLODEOHWRDOO B B B VSRROV,IPRUHWKDQRQHVSRROLVIXOO\VKLIWHGWKHRLOZLOOJRWRWKHVSRROZLWK WKHORZHVWSUHVVXUHUHTXLUHPHQWV+RZHYHULWLVSRVVLEOHWRPHWHUWKHÁRZ WRWKHVSRROZLWKWKHOHDVHORDGDQGSURYLGHÁRZWRWZRXQHTXDOORDGV (1+$1&('0(7(5,1*6(&7,216 7KH69069)695DQG69*VHFWLRQVKDYHPHWHULQJQRWFKHVPDFKLQHG P LQWRWKHVSRROWRDOORZIRUEHWWHU´IHDWKHULQJµRIDORDG7KHVSRROWUDYHOIRU WKHVH VHFWLRQV LV DOVR D OLWWOH ORQJHU DW µ YV µ IRU WKH VWDQGDUG VHFWLRQV,QDGGLWLRQWRWKHPHWHULQJQRWFKHVLQWKHVSRROWKHODQGVLQWKH 69)DQG69*ERGLHVKDYHEHHQPDFKLQHGWRJLYHPRUHSUHFLVHFRQWURO RYHU WKH ÁRZ 7KH PHWHULQJ QRWFKHV LQ WKH 69) DQG 69* KDYH EHHQ T A A A RSWLPL]HGIRUÁRZVRIJSPRUOHVV)RUHQKDQFHGPHWHULQJRQKLJKHU CONVERSION PLUG ÁRZVLWLVUHFRPPHQGHGWKDWWKH690RU695EHXVHG /2&.6(&7,216 7KH69/VHFWLRQFRPELQHVERWKDZD\GLUHFWLRQDOYDOYHDQGDGRXEOHSLORWRSHUDWHGFKHFNYDOYH7KLVSURYLGHVYHU\ ORZOHDNDJHZKHQWKHVSRROLVLQQHXWUDO:KHQWKHVSRROLVVKLIWHGRLOLVGLUHFWHGWKURXJKDZRUNSRUWFKHFNWRWKH F\OLQGHU3UHVVXUHRQWKHZRUNSRUWDSSOLHVSUHVVXUHWRWKHVKXWWOHVSRRORSHQLQJWKHRSSRVLWHFKHFNYDOYHDQGDOORZLQJ RLOWRUHWXUQLQWRWKHYDOYH'HSHQGLQJRQORDGSUHVVXUHVWKHPHWHULQJRIWKHVSRROPD\EHDIIHFWHG,QVRPHFDVHVD RQHZD\UHVWULFWRULQDZRUNSRUWPD\EHEHQHÀFLDO SERIES CIRCUIT SVS WORK SECTIONS TANK RETURN TANK RETURN PORT B PORT B PORT A PORT A SERIES SECTION VALVES $VHULHVFLUFXLWYDOYHLVPRVWFRPPRQO\XVHGWRFRQWUROPRUHWKDQ RQHK\GUDXOLFFRPSRQHQWVLPXOWDQHRXVO\7KHHQWLUHFLUFXLWÁRZ LVDYDLODEOHWRHDFKYDOYHVHFWLRQWKDWLVDFWXDWHG,QDWZRVSRRO VHULHVYDOYHZLWKERWKVSRROVDFWXDWHGWKHRLOÁRZVIURPWKHLQOHW WR WKH ZRUN SRUW RI WKH ÀUVW VHFWLRQ 7KH UHWXUQ ÁRZ RI WKH ÀUVW VHFWLRQLVGLUHFWHGWRWKHRSHQFHQWHUFRUHRIWKHVHFRQGVHFWLRQ ,QDSDUDOOHOYDOYHWKHUHWXUQRLOIURPWKHZRUNSRUWLVGLUHFWHGWR WKHWDQNFRUH)URPWKHRSHQFHQWHUFRUHRIWKHVHFRQGVHFWLRQ WKHRLOÁRZVWRWKHZRUNSRUWZLWKWKHUHWXUQRLOJRLQJWRWKHRXWOHW ,QDVHULHVFLUFXLWYDOYHWKHVXPPDWLRQRIWKHSUHVVXUHVUHTXLUHG IRUHDFKZRUNVHFWLRQZLOOHTXDOWKHWRWDOSUHVVXUHUHTXLUHGIRUWKH FLUFXLW7KHWRWDOSUHVVXUHUHTXLUHGPXVWQRWH[FHHGWKHV\VWHP UHOLHIVHWWLQJRUWKHSXPSSUHVVXUHUDWLQJ,WLVQRWUHTXLUHGWRKDYHD 696HULHVVHFWLRQDVWKHODVWVHFWLRQXQOHVVVHULHVÁRZLVUHTXLUHG WRDGRZQVWUHDPYDOYH,QWKLVDSSOLFDWLRQDSRZHUEH\RQGSOXJ PXVWEHXVHGLQWKHRXWOHWVHFWLRQ SERIES SECTION &20%,1('6(5,(63$5$//(/&,5&8,76 7KH696HULHVFLUFXLWYDOYHVHFWLRQVPD\EHVWDFNHGZLWK69SDUDOOHOFLUFXLWYDOYHVHFWLRQV7KLVDOORZVERWKVHULHVDQG SDUDOOHOFRQWUROLQWKHVDPHYDOYHDVVHPEO\ ,QWKHYDOYHDVVHPEO\VKRZQEHORZWKHÀUVWWKLUGDQGIRXUWKVHFWLRQVDUHSDUDOOHO7KHVHFRQGVHFWLRQLVVHULHV7KH ÀUVWSDUDOOHOVHFWLRQKDVSULRULW\RYHUDOOGRZQVWUHDPYDOYHV:KHQWKHVSRRORIWKHÀUVWSDUDOOHOVHFWLRQLVDFWXDWHGWKH UHWXUQRLOIURPWKHZRUNSRUWLVGLUHFWHGWRWKHWDQNFRUHWKXVRLOÁRZWRGRZQVWUHDPVHFWLRQVLVFXWRII7KHVHFRQGDQG WKLUGVHFWLRQVDUHLQVHULHVZLWKHDFKRWKHUDVLVWKHVHFRQGDQGIRXUWKVHFWLRQV7KHWKLUGDQGIRXUWKVHFWLRQVDUHLQ SDUDOOHOZLWKHDFKRWKHU 6(5,(6027256322/ 7KH696HULHV0RWRU6SRROSURYLGHVFRQWURORIUHYHUVLEOH K\GUDXOLFPRWRUV%RWKZRUNSRUWVDUHFRQQHFWHGWRWKH RSHQ FHQWHU FRUH LQ WKH QHXWUDO SRVLWLRQ ,W VKRXOG EH QRWHGWKDWLQWKHQHXWUDOSRVLWLRQWKHZRUNSRUWVZLOOEH HTXDOO\SUHVVXUL]HGWRWKHVDPHSUHVVXUHWKDWLVUHTXLUHG RIDQ\GRZQVWUHDPYDOYHVHFWLRQVDQGWKDWDZRUNSRUW UHOLHI LQ WKH VHFWLRQ ZLOO DOVR OLPLW WKH SUHVVXUH RI DQ\ RWKHUVHFWLRQVLQWKHYDOYH7KHVHULHVPRWRUVSRROVKRXOG QRWEHXVHGWRFRQWURODK\GUDXOLFF\OLQGHUDVXQZDQWHG F\OLQGHUGULIWPD\RFFXULQWKHQHXWUDOSRVLWLRQ &/26('&(17(5$33/,&$7,216 7KH696HULHV&LUFXLW9DOYHVHFWLRQVFDQQRWEHXVHGLQ DFORVHGFHQWHUYDOYHDVVHPEO\ CATV 27-07-13-02 TANK RETURN PORT B PORT A PARALLEL SECTION TANK RETURN TANK RETURN TANK RETURN PORT B PORT B PORT B PORT A PORT A PORT A SERIES SECTION PARALLEL SECTION PARALLEL SECTION 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 WORK SECTIONS VALVES SV WORK PORT RELIEF* 69:25.32575(/,()6237,21%&* +&$1%(25'(5('35(7(67('86( 25'(5&2'($75,*+7 PR MODEL NUMBER - PORT SIZE RELIEF TYPE PRESSURE SETTING 0 H- ADJUSTABLE SPECIFY RELIEF PRESSURE. LEAVE BLANK FOR STANDARD SETTINGS. CARTRIDGE ONLY $OVRXVHGDVVWDQGDUGPDLQUHOLHIRQO\PRGHOV DQG5'PRGHOV 9 - O 1500-3000 PSI L- ADJUSTABLE 500-1500 PSI NH- NON-ADJUSTABLE 1500-3000 PSI NL- NON-ADJUSTABLE 500-1500 PSI STANDARD SETTING: 2000 PSI for H and NH 1000 PSI for L and NL 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 17 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 28-07-13-02 SV INLET RELIEF OPTIONS OPTION 1 NO RELIEF TOP INLET 7KLVRSWLRQSURYLGHVQREXLOWLQUHOLHI7KLVLVXVHGZKHQDUHOLHILV SURYLGHGHOVHZKHUHLQWKHV\VWHPRULQDFORVHGFHQWHUDSSOLFDWLRQ 7KLVSOXJFDQEHUHSODFHGZLWKDUHOLHIFDUWULGJHDWDODWHUGDWH OPTION 4 LOW PRESSURE ADJUSTABLE RELIEF 7KLVRSWLRQSURYLGHVIRUDGLIIHUHQWLDOSRSSHWUHOLHIDGMXVWDEOHIURP 36,6HWDW36,#*30 OPTION 5 HIGH PRESSURE ADJUSTABLE RELIEF SVIXX 7KLVRSWLRQSURYLGHVIRUDGLIIHUHQWLDOSRSSHWUHOLHIDGMXVWDEOHIURP 36,6HWDW36,#*307KHGLIIHUHQWLDOSRSSHW UHOLHISURYLGHVVPRRWKTXLHWRSHUDWLRQZLWKKLJKFUDFNLQJSUHVVXUH SIDE INLET 5(/,()&$575,'*(6&$1%(25'(5('35(7(67('6((592;5(/,()3$*(9 SV OUTLET COVER OPTIONS TOP OUTLET POWER BEYOND PORT SIDE OUTLET "CC" STAMPED ON END OF CLOSED CENTER PLUG SVEXX 1.38 OPTION 2 POWER BEYOND OUTLET WITH #8 SAE BEYOND PORT 7KLVRSWLRQSURYLGHVIRUDKLJKSUHVVXUH SRZHUEH\RQGSRUW7KLVZRXOGEHXVHG LIDYDOYHLVWREHDGGHGGRZQVWUHDP 7+(287/(73257086767,//%( &211(&7('727$1.:KHQVSRROV DUHLQQHXWUDOWKHLQOHWLVFRQQHFWHGWR WKHSRZHUEH\RQGSRUW 2.00 OPTION 6 OPEN CENTER OUTLET PRESSURE BUILDUP VALVE FOR SOLENOID OPTION 7KLVRSWLRQGLUHFWVRLOIURPRSHQFHQWHUFRUHWKUXSUHVVXUH EXLOGXSYDOYHDQGWKHQWRWDQN6HHVROHQRLGVHFWLRQIRU GHVFULSWLRQRIRSHUDWLRQ OPTION 7 POWER BEYOND PRESSURE BUILD-UP VALVE FOR SOLENOID OPTION 7KLVRSWLRQGLUHFWVRLOIURPLQOHWWKUXSUHVVXUHEXLOGXSYDOYH DQGWKHQGRZQVWUHDP7KLVSUHVVXUHEXLOGXSYDOYHSURYLGHV D6$(SRZHUEH\RQGSRUW7KHRXWOHWPXVWEHFRQQHFWHG WRWDQN SV MID-INLET SECTION SVIM 1 X X - X X X X MID INLET PORT MID INLET RELIEF POWER CORE BLOCKING PLATE INSTALLS IN POWER CORE BETWEEN MID INLET & UPSTREAM SECTION. /DVW)RXU'LJLWV6SHFLI\ $1RQ6WDQGDUG5HOLHI3UHVVXUH :KHQEODQNUHIHUWRVWDQGDUGVHWWLQJ 1R5HOLHI 6+,0$GMXVWDEOH36,6WG6HWWLQJ36,#*30 6+,0$GMXVWDEOH36,6WG6HWWLQJ36,#*30 $GMXVWDEOH36,6WG6HWWLQJ36,#*30 $GMXVWDEOH36,6WG6HWWLQJ36,#*30 &&RPELQHG)ORZ0LG,QOHW 66SOLW)ORZ0LG,QOHWQRWDYDLODEOHDIWHUDVHULHVVHFWLRQ 6HH6HFWLRQ9LHZDWOHIW1RWH /RFDWLRQRI6SDFHU3DUW1XPEHU 3RUW6L]H6$(25%7+' DESCRIPTION: SPACER SPLIT MID-INLET SHOWN CAN BE CONVERTED TO COMBINED MID-INLET BY MOVING SPACER TO OPPOSITE END CATV 29-07-13-02 $0LG,QOHWSURYLGHVDQLQOHWSRUWIRUDVHFRQGSXPSPLGVWUHDPLQWKHYDOYHVWDFN$ UHOLHIFDQEHSURYLGHGLQWKLVVHFWLRQ:LWKWKHFRPELQHGÁRZWKHÁRZIURPERWKSXPSVLV DYDLODEOHWRWKHGRZQVWUHDPVHFWLRQVZKHQDOOWKHZRUNVHFWLRQVXSVWUHDPDUHLQQHXWUDO 7KHVSOLWÁRZFRPSOHWHO\VHSDUDWHVWKHWZRSXPSÁRZV7KHFRPPRQWDQNSDVVDJHLVDOO WKDWLVVKDUHGEHWZHHQWKHWZRSXPSÁRZVNote:6SOLWÁRZPLGLQOHWLVQRWDYDLODEOHZKHQ XVHGDIWHUDVHULHVVHFWLRQDQGWKHFRUHEORFNSODWHLVQRWXVHGDIWHUDVHULHVVHFWLRQ 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 15 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES PLEASE NOTEWKDWWKLVFORVHGFHQWHURSWLRQGRHVQRW SURYLGHIRUWKHGUDLQRIIRIVWDQGE\VSRROOHDNDJH7KLVFDQ DOORZDYHU\VPDOODPRXQWRIRLOWRHQWHUWKHZRUNSRUWVZKHQ LQQHXWUDO OPTION 1 STANDARD OPEN CENTER OUTLET WITH CONVERSION PLUG 7KLVLVWKHVWDQGDUGRXWOHWRS WLRQ7KLVRSWLRQDOORZVIRUFRQYHUVLRQ LQWKHÀHOGIRUSRZHUEH\RQGRUFORVHG FHQWHUDSSOLFDWLRQV:KHQVSRROVDUHLQ QHXWUDOWKHLQOHWLVXQORDGHGWRWDQN 1.00 OPTION 3 CLOSED CENTER OUTLET 7KLVRSWLRQSURYLGHVIRUFORVHGFHQWHURSHUDWLRQ7KLV LVW\SLFDOO\XVHGZLWKDYDULDEOHGLVSODFHPHQWSUHVVXUH FRPSHQVDWHGSXPSRULQDV\VWHPZLWKDQXQORDGLQJYDOYH :KHQWKHVSRROVDUHLQQHXWUDOWKHLQOHWSRUWLVEORFNHG &ORVHGFHQWHUFDQDOVREHDFFRPSOLVKHGE\SOXJJLQJWKH SRZHUEH\RQGSRUWRIRSWLRQ SV FLOW CONTROL INLET SECTION 7KH69I))ORZ&RQWURO,QOHWLV LQWHUFKDQJHDEOHZLWKWKHVWDQGDUG69 LQOHWVHFWLRQ SVIFXXXXXX PORT SIZE 6LGHDQG(QG,QOHW6$(25% 6LGHDQG(QG,QOHW6$( 25%ZLWK6$(25%([WHUQDO ()&LUFXLW SOLENOID OPTION 2PLWIRU)ORZ&RQWURO2SWLRQ0 49'&'RXEOH6SDGH&RLO 49'&'RXEOH6SDGH&RLO +9'&',1&RLO +9'&',1&RLO /9'&'RXEOH/HDG:LUH&RLO /9'&'RXEOH/HDG:LUH&RLO :9'&'RXEOH/HDG:LUHZ:HDWKHUSDN &RQQHFWRU&RLO :9'&'RXEOH/HDG:LUHZ:HDWKHUSDN &RQQHFWRU&RLO RELIEF VALVE 1R5HOLHI 'LUHFWDFWLQJQRQDGMXVWDEOH SVLVHWDWSVL 'LUHFWDFWLQJQRQDGMXVWDEOH SVLVHWDWSVL 'LUHFWDFWLQJDGMXVWDEOHSVL VHWDWSVL 'LUHFWDFWLQJDGMXVWDEOHSVL VHWDWSVL IRURWKHUVHWWLQJVSOHDVHVSHFLI\LH 69I)34LVVHWDWSVL #10 Rear Inlet Port )/2:&21752/237,216 3237,21LQFRUSRUDWHVDVROHQRLG RSHUDWHGHOHFWULFDOO\YDULDEOHSUHVVXUH FRPSHQVDWHGÁRZFRQWUROFDUWULGJH :LWKWKHVROHQRLGGHHQHUJL]HGDOO RIWKHLQOHWÁRZLVGLYHUWHGWRWKHWDQN FRUH()SRUW%\LQFUHDVLQJWKHFXUUHQW WKURXJKWKHVROHQRLGWKHÁRZGLUHFWHG WRWKHSRZHUFRUHDQGGRZQVWUHDP VHFWLRQVZLOOEHSURSRUWLRQDOO\ LQFUHDVHGWKHPD[LPXPUDWLQJRI WKHFDUWULGJHLVJSPDWP$ &RQWUROFXUUHQWLVQRUPDOO\SURYLGHG YLDDFRQWUROOHUFDUGSURYLGLQJD3:0 VLJQDO FLOW CONTROL OPTION 00DQXDO)ORZ&RQWURO 3(OHFWUR3URSRUWLRQDO 86ROHQRLG8QORDGLQJ 8237,21LQFRUSRUDWHVDVROHQRLG RSHUDWHGXQORDGHUFDUWULGJH:LWKWKH VROHQRLGGHHQHUJL]HGDOORIWKHLQOHW ÁRZLVGLYHUWHGWRWKHWDQNFRUH() SRUW:LWKWKHVROHQRLGHQHUJL]HGDOO WKHLQOHWÁRZLVGLUHFWHGWRWKHSRZHU FRUHDQGGRZQVWUHDPVHFWLRQV #10 Side Inlet Port IN Option P- Proportional flow control with manual override C-760 EF 0237,21LQFRUSRUDWHVDPDQXDOO\ RSHUDWHGSUHVVXUHFRPSHQVDWHGÁRZ FRQWUROFDUWULGJH:LWKWKHFRQWURONQRE WXUQHGIXOO\LQFORFNZLVHDOORIWKH LQOHWÁRZLVGLYHUWHGWRWKHWDQNFRUH ()SRUW%\WXUQLQJWKHÁRZFRQWURO NQREFRXQWHUFORFNZLVHWKHLQOHW ÁRZGLUHFWHGWRWKHSRZHUFRUHDQG GRZQVWUHDPVHFWLRQVLVSURSRUWLRQDOO\ LQFUHDVHG$SSUR[LPDWHO\UHYROXWLRQV YDULHVÁRZIURPQRÁRZWRIXOOÁRZ SVIFXXX-XX 5.18 VALVES 2.00 IN Optional #8 EF Port 3257237,217KHÁRZEHLQJ GLUHFWHGWRWKHWDQNFRUH()SRUWPD\ EHXWLOL]HGE\DVHFRQGFLUFXLWE\ LQVHUWLQJDSLSHSOXJLQWRWKHWDQN FRUHSDVVDJHRQWKHVHDOVLGHRIWKH FDVWLQJDQGWKHQFRQQHFWLQJWKH() SRUWWRWKHVHFRQGFLUFXLW IN IN PRESSURE CORE CONTROL OPTION P CIRCUIT SCHEMATIC PRESSURE CORE PRESSURE CORE CONTROL OPTION U CIRCUIT SCHEMATIC CONTROL OPTION M CIRCUIT SCHEMATIC PROPORTIONAL CONTROLLER BOX (for use with SVI)3ÀRZFRQWUROLQOHW PART NO. 671300048 7KHSURSRUWLRQDOFRQWUROOHUER[LVXVHGWRSURYLGHDQDGMXVWDEOHHOHFWULFDO VLJQDOWRDSURSRUWLRQDOVROHQRLGRQWKH69I)3LQOHW2QFHWKHGLDOLV VHWWKHUHJXODWHGÁRZWKURXJKWKHYDOYHVKRXOGUHPDLQDSSUR[LPDWHO\ FRQVWDQWUHJDUGOHVVRISUHVVXUH:LWKLQWKHRSHUDWLQJUDQJHÁRZYDULHV DSSUR[LPDWHO\OLQHDUO\ZLWKGLDOURWDWLRQ (1.75) 671300048 Prince Manufacturing Corporation SOL Output -Black Power Input RED+ BLACK- OFF ON Power Switch (4.63) Power OK 1 0 2 10 3 9 4 7 6 5 +Red (5.75) 8 CONNECTIONS AND OPERATION: &RQQHFWOHDGVWRWKHSRZHUVXSSO\DQGVROHQRLG3RZHUVXSSO\VKRXOGEH EHWZHHQDQG9'& :LWKWKHSRZHURIIWKHLQOHWÁRZLVGLUHFWHGWRWKHWDQNRUH[FHVVÁRZ SRUW 7RSURYLGHSRZHUWRWKHFRQWUROPRYHWKHSRZHUVZLWFKWR21*UHHQ /('LV21ZKHQFRQWUROLVSRZHUHG 0LQLPXPÁRZLVGLUHFWHGLQWRWKHYDOYHZKHQRQWKHGLDOLVDOLJQHGZLWK WKHFHQWHUPDUN0D[LPXPÁRZLVGLUHFWHGLQWRWKHYDOYHZKHQRQWKH GLDOLVDOLJQHGZLWKWKHFHQWHUPDUN &ORFNZLVHURWDWLRQLQFUHDVHVÁRZ 7\SLFDOO\QRDGMXVWPHQWVDUHQHHGHGIRURSHUDWLRQOPLQDQGOPD[SRWV DUHSUHVHWIRUWKHQRUPDOPD[LPXPDQGPLQLPXPÁRZV To proportional coil. Coil does not have polarity. (5.00) (2.50) (4.88) (.24) Mount using three #10-32 screws (not included) &RQWUROFRPHVZLWKIWRIFDEOHIRUSRZHUOHDGVDQGIWRI FDEOHIRUFRLOOHDGV&RQWUROER[SURWHFWLRQUDWLQJLV,3 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 15 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 30-07-13-02 JOYSTICK HANDLE FOR MODEL SV STACK VALVE HANDLE BACK 5th SPOOL OUT HANDLE LEFT 6th SPOOL IN SEE DETAIL AT LEFT HANDLE RIGHT 6th SPOOL OUT HANDLE VIEWED FROM TOP OFFSET HANDLE SHOWN HANDLE FRONT 5th SPOOL IN 7KLV LV D VSHFLDO KDQGOH IRU WKH PRGHO 69 VWDFN YDOYH WKDW DOORZV WKHVSRROVRIWZRDGMDFHQWVHFWLRQVWREHRSHUDWHGE\RQHFRPPRQ KDQGOH7KHVSRROVFDQEHRSHUDWHGLQGHSHQGHQWO\RUVLPXOWDQHRXVO\ GHSHQGLQJ RQ KDQGOH PRYHPHQW 7KH RSWLRQ LV QRUPDOO\ XVHG RQ VSULQJ FHQWHU WR QHXWUDO VHFWLRQV EXW FDQ DOVR EH XVHG RQ RWKHU VHFWLRQVVXFKDVÁRDWVHFWLRQV7KLVKDQGOHLVQRUPDOO\LQVWDOOHGRQ YDOYHVDVVHPEOHGDWWKHIDFWRU\EXWFDQEHLQVWDOOHGRQZRUNVHFWLRQV WKDWKDYHKDQGOHRSWLRQRU7KHGUDZLQJDWULJKWVKRZVWZRMR\ VWLFNVZLWKRIIVHWKDQGOHVLQVWDOOHGRQDVL[VHFWLRQYDOYH:KHQWZR MR\VWLFNVDUHLQVWDOOHGRQWKHVDPHYDOYHDVVHPEO\LWLVUHFRPPHQGHG WKDWWKHUHEHWZRVWDQGDUGVHFWLRQVEHWZHHQWKHPWRSUHYHQWKDQGOH LQWHUIHUHQFH$WZRVHFWLRQVSDFHULVDYDLODEOHSDUWQR -2<67,&.$66(0%/<:675$,*+7+$1'/( $66(0%/('219$/9( ........................... 69-6 .,7 .................................................... -2<67,&.$66(0%/<:2))6(7+$1'/( $66(0%/('219$/9( ...........................69-2 .,7 ..................................................... -2<67,&.$66(0%/<:%(17+$1'/( $66(0%/('219$/9( ........................... 69-% .,7 ..................................................... ONE WAY WORK PORT RESTRICTOR FOR SVH, SVM, SVR, SVF, SVS, SVG& SVL WORK SECTIONS 7KLVUHVWULFWRUZLOOUHVWULFWRLOLQRQHGLUHFWLRQDQG DOORZIUHHÁRZLQWKHRSSRVLWHGLUHFWLRQ7KLV UHVWULFWRUFRQVLVWVRIDQRULÀFHSODWHWKDWVLPSO\ GURSVLQWRWKH6$(ZRUNSRUWRID69+690 69569)69669*69/ZRUNVHFWLRQ Restricted Flow Free Flow VALVES 3OHDVHUHIHUWRWKHVHSDUWQXPEHUVDQGVWDWHZKLFKVHFWLRQVWKH KDQGOHLVWREHLQVWDOOHGRQZKHQRUGHULQJDYDOYHDVVHPEO\7KLV KDQGOH FDQ EH LQVWDOOHG LQ WKH ÀHOG WR ZRUN VHFWLRQV ZLWK KDQGOH RSWLRQQRKDQGOH $PROGHGUXEEHUERRWLVDYDLODEOHIRUWKHMR\VWLFN ONE WAY WORK PORT RESTRICTOR FOR SVW WORK SECTIONS 7KLVUHVWULFWRUZLOOUHVWULFWRLOLQRQHGLUHFWLRQDQGDOORZIUHH ÁRZLQWKHRSSRVLWHGLUHFWLRQ7KLVUHVWULFWRUFRQVLVWVRIWKH RULÀFHSODWHDVGHVFULEHGDWOHIWDQGDQDGDSWHUÀWWLQJWKDW DOORZXVHLQWKHVWDQGDUG69:6$(ZRUNSRUW Restricted Flow Free Flow ORDERING INFORMATION +(;%5$665(675,&725 #6 SAE 9/16-18 #8 SAE 3/4-16 ;;; 670805XXX ORDERING INFORMATION $'$37(5:+(;%5$665(675,&725 #6 SAE 9/16-18 #8 SAE 3/4-16 ;;; 661180XXX 648$5(67((/5(675,&725 661181XXX &21,&$/635,1* 7KHODVWWKUHHGLJLWVRISDUWQXPEHUDUHWKHRULÀFHVL]HLQ WKRXVDQGWKVRIDQLQFKEXAMPLE: #6 SAE 9/16-18THD #8 SAE 3/4-16THD 25,),&( 25,),&( 1225,),&( $'$37(5:,7+648$5(67((/ 661182XXX 5(675,&725$1'&21,&$/635,1* 7KHODVWWKUHHGLJLWVRISDUWQXPEHUDUHWKHRULÀFHVL]HLQ WKRXVDQGWKVRIDQLQFKEXAMPLE: #6 SAE 9/16-18THD #8 SAE 3/4-16THD 25,),&( 25,),&( 1225,),&( CATV 31-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 17 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 'LUHFWLRQDO&RQWURO9DOYHV SV SOLENOID OPERATED :RUN6HFWLRQV 7\SH³'´DQG³7´6ROHQRLG2SHUDWHG 7\SH³&´DQG³6´6ROHQRLGDQG0DQXDO2SHUDWLRQ VALVES STANDARD FEATURES 2SHQFHQWHURUFORVHGFHQWHUDSSOLFDWLRQV 3RUWUHOLHIRSWLRQVDYDLODEOH ,QWHUQDOSLORWVXSSO\DQGGUDLQ 9'&9'&DQG9$& 3RZHUEH\RQGFDSDELOLW\ /RDGFKHFNVRQHDFKVHFWLRQ 0D\EHVWDFNHGZLWK0DQXDO696HFWLRQV 6HULHV³&´DQG³'´PRUHHFRQRPLFDO DQGFRPSDFW SPECIFICATIONS 3DUDOOHORU6HULHV&LUFXLW&RQVWUXFWLRQ 3UHVVXUH5DWLQJ Maximum Operating Pressure 3000 psi Maximum Tank Pressure 150 psi 1RPLQDO)ORZ5DWLQJ 12 GPM 'LIIHUHQWLDO3UHVVXUH 5HTXLUHGWR$FWXDWRU $SSUR[36, )LOWUDWLRQ)RUJHQHUDOSXUSRVHYDOYHVÁXLG cleanliness should meet the ISO 4406 19/17/14 level. For extended life or for pilot operated valves, WKHÁXLGFOHDQOLQHVVOHYHOLVUHFRPPHQGHG V32 )RRW0RXQWLQJ 0D[LPXP2SHUDWLQJ7HPS ............................180°F :HLJKW3HU6HFWLRQ Inlet Section .................................... Approx. 3.75 Ibs. Outlet Section ................................. Approx. 3.75 Ibs. Solenoid Operated Type “-D” and “-T” Work Section ......Approx. 11.0 Ibs. 7\SH´&µDQG´6µ:RUN6HFWLRQ .... Approx. 14.5 Ibs. 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 32-02-15-03 SV (8 SERIES) SOLENOID OR MANUAL WORK SECTIONS (BOTH SOLENOIDS ON ONE END) DESCRIPTION OF OPERATION 7KH7\SH³&´696ROHQRLG:RUN6HFWLRQ allows remote electrical on-off or manual control. The “-C” sections are 8 series work sections which use screw in cartridges with a #8 thread size. The screw in cartridges provide a robust platform for the higher tank pressures often seen in mobile applications and the #8 size allows for a more compact section size. Cartridges and coils on the 8 series are not interchangeable with the Prince 10 series solenoid sections or sections manufactured prior to November 2014. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince SV solenoid operated work sections may be used in any combination within a stack valve assembly. 7KH7\SH³&´696ROHQRLG6HFWLRQ contains two 3-way 2-position, #8 solenoid cartridge valves and a pilot operated piston attached to the main control spool. When both solenoids are de-energized, both sides of the pilot piston are open to tank pressure and the spool remains spring centered. When solenoid “A” is energized, pilot pressure is applied to one VLGHRIWKHSLORWSLVWRQFDXVLQJWKHVSRROWRVKLIWIURPWKHQHXWUDOSRVLWLRQDQGGLUHFWÁRZWRZRUNSRUW´$µ:KHQVROHQRLG ´%µLVHQHUJL]HGSLORWSUHVVXUHLVDSSOLHGWRWKHRWKHUVLGHRIWKHSLORWSLVWRQFDXVLQJWKHVSRROWRVKLIWDQGGLUHFWÁRZ to work port “B”. An optional manual override feature is available for the solenoid cartridges. ,QWHUQDOSLORWOLQHV provide pilot pressure to the solenoid actuator. Pilot pressure is generated by a “Pressure Build-Up Valve” that is installed in the standard outlet section. Two versions of the pressure build-up valve are offered, the open center pressure build-up valve and power beyond pressure build-up valve. Both versions supply 150-200 PSI pilot pressure to the solenoid actuator. A closed center assembly does not require a pressure build-up valve. For an open FHQWHUV\VWHPWKHSLORWSUHVVXUHFDQDOVREHSURYLGHGE\DQLQLQOHWPDQLIROGZKLFKFDQSURYLGHÀOWHUHGSLORWÁRZ ORDER CODE MATRIX - TYPE “-C” SOLENOID OR MANUAL WORK SECTIONS 6(5,(662/(12,'23(5$7('69:690$1'69/6(&7,21 SVWXXXX–CXXX SECTION TYPE W-Standard Work Section L-Lock Section (Use C Spool) M-Metering Work Section (Use E or F Spool) COIL VOLTAGE & TERMINATION * 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor E-4-Way 3 Psition Metering (SVM only) F-3-Way 3 Psition Metering (SVM only) SPOOL ACTIONS SOLENOID OPERATION A - Spring Center C - Standard Solenoid Cartridge CM - Solenoid Cartridge w/Manual Override HANDLE OPTION 1. Std. Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only 6. Clevis Spool End Only 7. Vertical Handle 8. Straight Handle VALVES PORT SIZE 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 12D, 12VDC Integral Deutsch 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 24D, 24VDC Integral Deutsch 11H, 120 VAC DIN 43650 11. Enclosed Handle 12. Extended Enclosed Handle 8 SERIES SOLENOID OPERATED PORT RELIEF WORK SECTIONS SVHXXX XXX–CXXX SECTION TYPE H-Port Relief Section S-Series Section (Use G Spool) R-Metering Work Section (Use E or F Spool) PORT SIZE 1. #8 SAE SPOOL TYPE A-3-Way 3-Position E-4-Way 3 Position Metering (SVR only) B-4-Way 3-Position F-3-Way 3 Position Metering (SVR only) C-4-Way 3-Position Motor G-4-Way Series SPOOL ACTIONS 12Q,12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 12D, 12VDC Integral Deutsch 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 24D, 24VDC Integral Deutsch 11H, 120 VAC DIN 43650 SOLENOID OPERATION C - Standard Solenoid Cartridge CM - Solenoid Cartridge w/Manual Override PORT RELIEF “B” OPTION A - Spring Center HANDLE OPTION 1. Std. Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only 6. Clevis Spool End Only 7. Vertical Handle 12. Extended Enclosed Handle *See page V38.5 for Coil details CATV 33-02-15-03 COIL VOLTAGE & TERMINATION* A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI PORT RELIEF “A” OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI G-Adjustable Direct Acting Relief 1500-3000 H-Adjustable Direct Acting Relief 500-1500 PSI 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V33 SV (8 SERIES) SOLENOID WORK SECTION (SOLENOID ON BOTH ENDS) DESCRIPTION OF OPERATION 7KH7\SH³'´696ROHQRLG:RUN6HFWLRQ allows remote electrical on-off control. The “-D” sections are 8 series work sections which use screw in cartridges with a #8 thread size. The screw in cartridges provide a robust platform for the higher tank pressures often seen in mobile applications and the #8 size allows for a more compact section size. Cartridges and coils on the 8 series are not interchangeable with the Prince 10 series solenoid sections or sections manufactured prior to November 2014. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince SV solenoid operated work sections may be used in any combination within a stack valve assembly. 7KH7\SH³'´696ROHQRLG6HFWLRQ contains two 3-way 2-position, #8 solenoid cartridge valves, one at each end of the main valve body. When both solenoids are de-energized, both ends of the control valve spool are open to tank pressure and the spool remains spring centered. When solenoid “A” is energized, pilot pressure is applied to one end RIWKHFRQWUROYDOYHVSRROFDXVLQJWKHVSRROWRVKLIWIURPWKHQHXWUDOSRVLWLRQWRIXOOVWURNHZKLFKGLUHFWVÁRZWRZRUNSRUW “A”. When solenoid “B” is energized, pilot pressure is applied to the other end of the control valve spool, causing the VSRROWRVKLIWWRIXOOVWURNHZKLFKGLUHFWVÁRZWRZRUNSRUW´%µ$QRSWLRQDOPDQXDORYHUULGHIHDWXUHLVDYDLODEOHIRUWKH solenoid cartridges. ,QWHUQDOSLORWOLQHVprovide pilot pressure to the solenoid actuator. Pilot pressure is generated by a “Pressure Build-Up Valve” that is installed in the standard outlet section. Two versions of the pressure build-up valve are offered, the open center pressure build-up valve and power beyond pressure build-up valve. Both versions supply 150-200 PSI pilot pressure to the solenoid actuator. A closed center assembly does not require a pressure build-up valve. For an open FHQWHUV\VWHPWKHSLORWSUHVVXUHFDQDOVREHSURYLGHGE\DQLQLQOHWPDQLIROGZKLFKFDQSURYLGHÀOWHUHGSLORWÁRZ ORDER CODE MATRIX - TYPE “-D” SOLENOID OR MANUAL WORK SECTIONS 6(5,(662/(12,'23(5$7('69:690$1'69/:25.6(&7,216 SVWXXX—DXXX SECTION TYPE W-Standard Work Section L-Lock Section (Use C Spool) M-Metering Work Section (Use E or F Spool) COIL VOLTAGE & TERMINATION * VALVES 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 12D 12 VDC Integral Deutsch 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 24D 24 VDC Integral Deutsch 11H, 120 VAC Din 43650 PORT SIZE 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor E-4-Way 3-Position Metering (SVM only) F-3-Way 3-Position Metering (SVM only) SOLENOID OPERATION D - Standard Solenoid Cartridge DM - Solenoid Cartridge w/Manual Override SPOOL ACTIONS A - Spring Center 8 SERIES SOLENOID OPERATED PORT RELIEF WORK SECTION SVH XXXXX—DXXX SECTION TYPE COIL VOLTAGE & TERMINATION * H-Port Relief Section S-Series Section (Use G Spool) R-Metering Work Section (Use E or F Spool) 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 12D 12 VDC Integral Deutsch 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 24D 24 VDC Integral Deutsch 11H, 120 VAC DIN 43650 PORT SIZE 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor G-4-Way Series E-4-Way 3-Position Metering (SVR only) F-3-Way 3-Position Metering (SVR only) SPOOL ACTIONS SOLENOID OPERATION D - Standard Solenoid Cartridge DM - Solenoid Cartridge w/Manual Override A - Spring Center PORT RELIEF “A” OPTION PORT RELIEF “B” OPTION A-Relief Cavity Plugged A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI G-Adjustable Direct Acting Relief 1500-3000 PSI G-Adjustable Direct Acting Relief 1500-3000 PSI H-Adjustable Direct Acting Relief 500-1500 PSI H-Adjustable Direct Acting Relief 500-1500 PSI * See page V38.5 for coil details V34 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 34-02-15-03 SV “8 SERIES” TYPE C SOLENOID OR MANUAL WORK SECTION DIMENSIONS 6.21 4.11 1.50 1.437 PART NUMBER WILL BE STAMPED IN THIS LOCATION 5.45 5.34 1.75 ‘A’ SOLENOID ‘B’ SOLENOID “B” WORK PORT “A” WORK PORT PORT RELIEF OPTIONS “8 SERIES” SOLENOID CARTRIDGE 660263014 VALVES PILOT PISTON TANK CORE PARALLEL POWER CORE LOAD CHECK INTERNAL PIOT LINES SV “8 SERIES” TYPE D SOLENOID WORK SECTION DIMENSIONS 5.85 C-899 1.437 5.34 11.66 3.16 ‘B’ SOLENOID “8 SERIES” SOLENOID CARTRIDGE 660263014 ‘B’ WORK PORT RESTRICTOR ORIFICE CATV 35-02-15-03 ‘A’ SOLENOID ‘A’ WORK PORT LOAD CHECK INTERNAL PILOT LINES 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V35 SV (10 SERIES) SOLENOID OR MANUAL WORK SECTIONS (BOTH SOLENOIDS ON ONE END) DESCRIPTION OF OPERATION 7KH7\SH³6´696ROHQRLG:RUN6HFWLRQ allows remote electrical on-off or manual control. The “-S” sections are 10 series work sections which use screw in cartridges with a #10 thread size. Cartridges and coils on the 10 series will be interchangeable with the components on Prince solenoid operated valves manufactured prior to November 2014 was well as current production 10 series valves. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince SV solenoid operated work sections may be used in any combination within a stack valve assembly. 7KH7\SH³6´696ROHQRLG6HFWLRQ contains two 3-way 2-position, #10 solenoid cartridge valves and a pilot operated piston attached to the main control spool. When both solenoids are de-energized, both sides of the pilot piston are open to tank pressure and the spool remains spring centered. When solenoid “A” is energized, pilot pressure is applied to RQHVLGHRIWKHSLORWSLVWRQFDXVLQJWKHVSRROWRVKLIWIURPWKHQHXWUDOSRVLWLRQDQGGLUHFWÁRZWRZRUNSRUW´$µ:KHQ solenoid “B” is energized, pilot pressure is applied to the other side of the pilot piston, causing the spool to shift and GLUHFWÁRZWRZRUNSRUW´%µ ,QWHUQDOSLORWOLQHV provide pilot pressure to the solenoid actuator. Pilot pressure is generated by a “Pressure Build-Up Valve” that is installed in the standard outlet section. Two versions of the pressure build-up valve are offered, the open center pressure build-up valve and power beyond pressure build-up valve. Both versions supply 150-200 PSI pilot pressure to the solenoid actuator. A closed center assembly does not require a pressure build-up valve. For an open FHQWHUV\VWHPWKHSLORWSUHVVXUHFDQDOVREHSURYLGHGE\DQLQLQOHWPDQLIROGZKLFKFDQSURYLGHÀOWHUHGSLORWÁRZ ORDER CODE MATRIX - TYPE “-S” SOLENOID OR MANUAL WORK SECTIONS 10 SERIES SOLENOID OPERATED SVW AND SVL SECTION SVWXXXX–SXXX SECTION TYPE W-Standard Work Section L-Lock Section (Use C Spool) COIL VOLTAGE & TERMINATION * 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11C, 120 VAC Conduit 11H, 120 VAC DIN 43650 PORT SIZE VALVES 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor SPOOL ACTIONS A - Spring Center SOLENOID AND MANUAL OPERATION HANDLE OPTION 1. Std. Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only 6. Clevis Spool End Only 7. Vertical Handle 8. Straight Handle 11. Enclosed Handle 12. Extended Enclosed Handle 10 SERIES SOLENOID OPERATED PORT RELIEF WORK SECTIONS SVHXXX XXX–SXXX SECTION TYPE COIL VOLTAGE & TERMINATION* H-Port Relief Section S-Series Section (Use G spool) 12Q,12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11C,120 VAC Conduit 11H, 120 VAC DIN 43650 PORT SIZE 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor G-4-Way Series SOLENOID AND MANUAL OPERATION PORT RELIEF “B” OPTION SPOOL ACTIONS A - Spring Center HANDLE OPTION 1. Std. Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only 6. Clevis Spool End Only 7. Vertical Handle 12. Extended Enclosed Handle *See page V38.5 for Coil details V36 A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI PORT RELIEF “A” OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI G-Adjustable Direct Acting Relief 1500-3000 H-Adjustable Direct Acting Relief 500-1500 PSI 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 36-02-15-03 SV (10 SERIES) SOLENOID WORK SECTION (SOLENOID ON BOTH ENDS) DESCRIPTION OF OPERATION 7KH7\SH³7´696ROHQRLG:RUN6HFWLRQ allows remote electrical on-off control. The “-T” sections are 10 series work sections which use screw in cartridges with a #10 thread size. Cartridges and coils on the 10 series will be interchangeable with the components on Prince solenoid operated valves manufactured prior to November 2014 was well as current production 10 series valves. Any of the standard “-S”, “-T”, “-C” or “-D” style Prince SV solenoid operated work sections may be used in any combination within a stack valve assembly. 7KH7\SH³7´696ROHQRLG6HFWLRQ contains two 3-way 2-position, #10 solenoid cartridge valves, one at each end of the main valve body. When both solenoids are de-energized, both ends of the control valve spool are open to tank pressure and the spool remains spring centered. When solenoid “A” is energized, pilot pressure is applied to one end RIWKHFRQWUROYDOYHVSRROFDXVLQJWKHVSRROWRVKLIWIURPWKHQHXWUDOSRVLWLRQWRIXOOVWURNHZKLFKGLUHFWVÁRZWRZRUNSRUW “A”. When solenoid “B” is energized, pilot pressure is applied to the other end of the control valve spool, causing the VSRROWRVKLIWWRIXOOVWURNHZKLFKGLUHFWVÁRZWRZRUNSRUW´%µ ,QWHUQDOSLORWOLQHV provide pilot pressure to the solenoid actuator. Pilot pressure is generated by a “Pressure Build-Up Valve” that is installed in the standard outlet section. Two versions of the pressure build-up valve are offered, the open center pressure build-up valve and power beyond pressure build-up valve. Both versions supply 150-200 PSI pilot pressure to the solenoid actuator. A closed center assembly does not require a pressure build-up valve. For an open FHQWHUV\VWHPWKHSLORWSUHVVXUHFDQDOVREHSURYLGHGE\DQLQLQOHWPDQLIROGZKLFKFDQSURYLGHÀOWHUHGSLORWÁRZ ORDER CODE MATRIX - TYPE “-T” SOLENOID OR MANUAL WORK SECTIONS 10 SERIES SOLENOID OPERATED SVW AND SVL WORK SECTIONS SVWXXX—TXXX SECTION TYPE W-Standard Work Section L-Lock Section (Use C Spool) COIL VOLTAGE & TERMINATION * 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor VALVES 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24 L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11C, 120 VAC Conduit 11H, 120 VAC Din 43650 PORT SIZE SPOOL ACTIONS A - Spring Center SOLENOID OPERATION 10 SERIES SOLENOID OPERATED PORT RELIEF WORK SECTION SVH XXXXX—TXXX SECTION TYPE COIL VOLTAGE & TERMINATION * H-Port Relief Section S-Series Section (Use G spool) 12Q, 12 VDC Double Spade 12L, 12 VDC Double Wire 12H, 12 VDC DIN 43650 24Q, 24 VDC Double Spade 24L, 24 VDC Double Wire 24H, 24 VDC DIN 43650 11C, 120 VAC Conduit 11H, 120 VAC DIN 43650 PORT SIZE 1. #8 SAE SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3-Position Motor G-4-Way Series SPOOL ACTIONS SOLENOID OPERATION A - Spring Center PORT RELIEF “A” OPTION PORT RELIEF “B” OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI G-Adjustable Direct Acting Relief 1500-3000 PSI H-Adjustable Direct Acting Relief 500-1500 PSI A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 1500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-1500 PSI G-Adjustable Direct Acting Relief 1500-3000 PSI H-Adjustable Direct Acting Relief 500-1500 PSI * See page V38.5 for coil details CATV 37-02-15-03 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V37 SV “10 SERIES” TYPE S SOLENOID OR MANUAL WORK SECTION DIMENSIONS C–623 7.47 4.50 1.437 PART NUMBER WILL BE STAMPED IN THIS LOCATION 1.50 5.34 5.94 COIL NUT 671800021 1.75 ‘A’ SOLENOID ‘B’ SOLENOID ‘A’ WORK PORT ‘B’ WORK PORT PORT RELIEF OPTIONS “10 SERIES” TYPE “S” SOLENOID CARTRIDGE 660263002 PILOT PISTON VALVES *WHEN EXTERNAL PILOT OR DRAIN IS USED THE INTERNAL LINES MUST BE PLUGGED EXTERNAL PILOT “TANK” PORT* EXTERNAL PILOT “PRESSURE” PORT* TANK CORE PARALLEL POWER CORE LOAD CHECK INTERNAL PILOT LINES SV “10 SERIES” TYPE T SOLENOID WORK SECTION DIMENSIONS 5.89 C – 635 1.437 3.50 5.34 12.34 COIL NUT 671800021 ‘B’ SOLENOID ‘A’ SOLENOID ‘B’ WORK PORT ‘A’ WORK PORT “10 SERIES” TYPE “T” SOLENOID CARTRIDGE 660263001 RESTRICTOR ORIFICE V38 LOAD CHECK INTERNAL PILOT LINES 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 16, 17 & 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 38-02-15-03 SV SOLENOID OPERATED WORK SECTION - APPLICATION INFORMATION )RURYHUFHQWHURUOLJKWORDGDSSOLFDWLRQV if the required work port load pressure drops below 200 PSI, the pilot pressure to the spool will drop to the same pressure causing the spring to move the control spool back towards the neutral position. The spool will end up in an intermediate position between neutral and fully shifted. $UHVWULFWRULQVWDOOHGLQWKHZRUN SRUWRUOLQHPD\EHUHTXLUHGIRUWKLVW\SHRIDSSOLFDWLRQ )RUFORVHGFHQWHUDSSOLFDWLRQV the Pressure Build-Up Valve is not required. However, a system pressure of 200 PSI must be maintained in the closed center position to actuate the valve properly. Proper operation of the solenoid actuators requires a pressure differential of 150-200 PSI above tank pressure. 7KH PD[LPXPWDQNSRUWSUHVVXUHVKRXOGQRWH[FHHG36, On “C” and “S” solenoid sections, excessive tank pressure will increase “Seal Drag” and may prohibit, the spool from shifting. The solenoid operated SV section may be converted to accept an external hydraulic pilot supply to the solenoid actuators. Please consult a Sales Representative for more information. COIL PART NUMBERS COIL SPECIFICATIONS 12H 12L 12Q 12D 24H 24L 24Q 24D 11H DUTY RATING ...............CONTINUOUS AT 100% VOLTAGE INGRESS PROTECTION RATING ................................. IP65 IP69 FOR INTEGRAL DEUTSCH COIL & CONNECTOR WATTAGE ..............................................................19 WATTS AMPERAGE DRAW (NOMINAL) 12 VOLT ..................... 1.6 AMPS 24 VOLT ................... 0.78 AMPS 110 VOLT.................. 0.19 AMPS LEAD WIRE LENGTH ..... 18 GAUGE 24” LONG AC COILS HAVE INTERNAL FULL WAVE RECTIFIERS RATED FOR 1000 VOLTS MAX REVERSE VOLTAGE DIN STYLE COILS ARE DIN 43650 TYPE A DEUTSCH COILS USE DT04-2P CONNECTORS – 671302168 – 671302160 – 671302165 – 671302163 – 671302169 – 671302167 – 671302166 – 671302164 – 671302170 -12 VDC DIN-43650 -12 VDC DUAL LEAD WIRES - 12 VDC DUAL SPADE - 12 VDC INTEGRAL DEUTSCH - 24 VDC DIN-43650 - 24 VDC DUAL LEAD WIRES - 24 VDC DUAL SPADE - 24 VDC INTEGRAL DEUTSCH - 110 VAC DIN-43650 VALVES SERIES 8 SOLENOID COILS ALL “C” AND “D” WORK SECTIONS SERIES 10 SOLENOID COILS ALL “S” AND “T” WORK SECTIONS COIL PART NUMBERS COIL SPECIFICATIONS 12H 12L 12Q 24H 24L 24Q 11C 11H DUTY RATING ...............CONTINUOUS AT 100% VOLTAGE INGRESS PROTECTION RATING ................................. IP65 WATTAGE ..............................................................20 WATTS STABILIZED TEMPERATURE 217°F WITH 77°F AMBIENT AMP DRAW AT 77° 12VOLT .................... 1.70 AMPS 24 VOLT ..................... .83 AMPS 120 VOLT.................... .18 AMPS LEAD WIRE LENGTH ..... 18 GAUGE 12” LONG AC COILS ARE INTERNALLY RECTIFIED WITH A FULL WAVE BRIDGE (NO IN RUSH CURRENT). DIN STYLE COILS ARE DIN 43650 TYPE A. – 671302002 – 671302003 – 671322004 – 671302006 – 671302007 – 671322008 – 671302009 – 671302010 - 12 VDC COIL DIN 43650 - 12 VDC COIL DOUBLE WIRE - 12 VDC COIL DOUBLE SPADE - 24 VDC COIL DIN 43650 - 24 VDC COIL DOUBLE WIRE - 24 VDC COIL DOUBLE SPADE - 120 VAC COIL CONDUIT - 120 VAC COIL DIN 43650 6<0%2/6&+(0$7,&2)$6(&7,2162/(12,'23(5$7('67$&.9$/9($66(0%/< SVI25 CATV 38.5-02-15-01 SVW1BA1 – C12Q OR SVW1BA1 – S12Q A B SVW1BA – D12Q OR SVW1BA – T12Q A SOL A SOL A SOL B SOL A B SOL B A SOL B B SVH1BA1GB – C12Q OR SVH1BA1GB – S12Q 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 19 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING SVE26 V38.5 RADIO REMOTE OFFERINGS FOR ON/OFF SOLENOID OPERATED VALVES MACRO TRANSMITTERS 4 buttons (2 section valve) #671303111 FEATURES: 6 buttons (3 section valve) #671303112 3DOPVL]HGWUDQVPLWWHU[[W\SLFDO 5HFKDUJHDEOHWUDQVPLWWHUPLFUR86%KURI DFWLYHWUDQVPLWWLQJEDWWHU\OLIH 5DQJHRIXSWRIW 7ZRZD\FRPPXQLFDWLRQZLWKUHDOWLPHIHHGEDFN 8 buttons (4 section valve) #671303113 (DV\V\QFZLWKUHFHLYHU +] ,QJUHVVSURWHFWLRQ,3 5HFHLYHULQSXWYROWDJH9'& VALVES CHARGER (MICRO USB) RECEIVERS 12 VDC car charger #671303003 Wall charger #671303005 4 outputs (up to 2 section valve) #671303001 8 outputs (up to 4 section valve) #671303002 Belly pack type controls available per quote. V38.6 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV-38.6-8-15-01 MODEL RD5000 MONO-BLOCK Directional Control Valves 1, 2, 3 Spool VALVES Model RD5100 Model RD5200 Model RD5300 CATV 39-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 MODEL RD5000 DIMENSIONAL DATA OPTIONAL, TOP OR BOTTOM PORTING (OUTLET PORT) 4.88 3.97 3.62 1.83 .406 DIA. (3) .65 5.00 3.00 B SPOOL TRAVEL .313 EACH WAY FROM NEUTRAL .531 "IN" FOR FLOAT FLOAT OPTION HCI-PRINCE OUT BYD .85 1.56 A STD. INLET PORT LOCATION 8.50 3.30 IN 1.28 6.10 2.20 3.75 OPTIONAL, TOP OR BOTTOM PORTING (INLET PORT) MODEL RD5100 CAPACITY: 30 GPM MAX. PRESSURE: 3000 PSI WEIGHT: 14 LBS. STD. OUTLET PORT LOCATION OR POWER BEYOND OPTIONS WORK PORTS A & B 1.50 9.44 12.63 OPTIONAL, TOP OR BOTTOM PORTING (OUTLET PORT) STD. OUTLET PORT LOCATION OR POWER BEYOND OPTIONS 4.88 3.97 3.62 1.83 .406 DIA. (3) .65 SPOOL TRAVEL .313 EACH WAY FROM NEUTRAL .531 "IN" FOR FLOAT STD. INLET PORT LOCATION OUT BYD .85 MODEL RD5200 CAPACITY: 25 GPM MAX. PRESSURE: 3000 PSI WEIGHT: 23 LBS. 1.56 C 7.25 5.25 2.25 B 3.30 A IN 1.28 6.10 2.20 3.75 OPTIONAL, TOP OR BOTTOM PORTING (INLET PORT) 8.50 1.50 9.44 WORK PORTS A, B, C & D OPTIONAL, TOP OR BOTTOM PORTING (OUTLET PORT) STD. OUTLET PORT LOCATION OR POWER BEYOND OPTIONS 4.88 3.97 3.62 1.83 .406 DIA. (3) 12.63 .65 .85 SPOOL TRAVEL .313 EACH WAY FROM NEUTRAL .531 "IN" FOR FLOAT MODEL RD5300 CAPACITY: 25 GPM MAX. PRESSURE: 3000 PSI WEIGHT: 34 LBS. OUT BYD 1.56 STD. INLET PORT LOCATION F 2.25 E 9.50 7.50 2.25 D A 8.50 3.57 IN 9 FLOAT OPTION C B OPTIONAL, TOP OR BOTTOM PORTING (INLET PORT) HCI-PRINCE VALVES FLOAT OPTION HCI-PRINCE D 2.20 3.75 1.28 6.10 WORK PORTS A, B, C, 1.50 D, E & F 9.44 12.63 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 40-07-13-02 RD5000 ORDER CODE SPECIAL VALVES AVAILABLE: RD5000 Mono-block Valves other than the standard models listed can be made to order. Use the order code matrix EHORZWRJHQHUDWHDPRGHOQXPEHUWKDWPHHWV\RXUUHTXLUHPHQWV6SHFLDOIHDWXUHVQRWOLVWHGFDQRIWHQEHPDGHWR \RXUVSHFLÀFDWLRQV$PLQLPXPRUGHUTXDQWLW\PD\DSSO\WRVSHFLDOYDOYHV3OHDVHFRQVXOW\RXUVDOHVUHSUHVHQWDWLYH MODEL RD5000 ORDER CODE MATRIX: )LOOHDFKER[ZLWKRQHOHWWHURUQXPEHUIURPHDFKFROXPQWRJHQHUDWHDPRGHOQXPEHU 1RWHWKDWÀUVWDOOVSRROVDUHOLVWHGWKHQDOOVSRRODWWDFKPHQWV FIRST SPOOL SECOND SPOOL THIRD SPOOL RD53 RD52 RD51 RD52 Two Spool RD53 Three Spool SPOOL TYPE SPOOL ATTACHMENTS RELIEF VALVE 2 3/4 NPTF In/Out 1/2 NPTF Work A 3 Way, 3 Position Open Center 1 No Relief 3 3/4 NPTF In/Out 3/4 NPTF Work C 4 Way, 3 Position Tandem Center 5 #12 SAE In/Out #12 SAE Work E 4 Way, 3 Position Open Center Motor Spool A 3 Position Spring Center to Neutral B 3 Position Detent (No Centering Spring) C Friction Detent (Detented in Neutral Only) D Rotary Actuator w/Center Detent (only available w/Handle 3 or 4 and Spool J) E Pressure Release Detent 1 Position Detent, Spool "out" Only, Spring Center to Neutral F** Pressure Release Detent 2 Position Detent, Spool "in" and "out", Spring Center to Neutral Spool "C" or "E" Only G** 4 Position, Spring Center to Neutral, Detent Spool In for Float Position H Spring Center Pneumatic Actuator N 1 Position Detent Spool "out" Spring Center to Neutral P 2 Position Detent Spool "in and out", Spring Center to Neutral R 3 Position Spring Center with Micro-Switch and Boot (actuates with spool in or out movement) S 2 Position Detent "Neutral and out", No "in" Position PORT SIZE 6 #12 SAE In/Out #10 SAE Work 9 #10 SAE In/Out #8 SAE Work Other Ports Please Specify G** 4 Way, 4 Position Tandem Center Float Spool J 4 Way, 3 Position Tandem Center Rotary Acuator (Spool Attachment D Only) **Spool option "G", and spool attachment "F", and "G" are available on the first spool only. Spool option "G" must be ordered with spool attachment option "G". *RD532CCCAAA5A4B1-25 2 Differential Poppet Non-Adjustable Set at 1000 PSI 3 Differential Poppet Non-Adjustable Set at 2000 PSI 4 Differential Poppet Adjustable 500-1500 PSI Set at 1000 PSI INLET LOCATION A End B Top C Bolt OUTLET LOCATION 1 END (with Power Beyond Option A) POWER BEYOND A Not Provided (only available with outlet location 1) 2 TOP 4 END (with Power Beyond Option B, C, D, F) Standard 5 Differential Poppet Adjustable 1500-3000 PSI Set at 2000 PSI B Conversion Plug Installed C Power Beyond Plug Installed with 3/4 NPTF HANDLE 1 With Complete Handle Assembly 2 Less Handle Only VALVES MODEL NUMBER RD51 Single Spool 3 Without Handle Assembly 4 Rotary Handle RD5200 o D Closed Center Conversion Plug Installed 5*** Bent Joystick Handle 6*** Straight Joystick Handle F Power Beyond Plug Installed with #12 SAE * For other Relief Settings Please Specify 7 Locking Handle Joystick can be installed on RD5300 on special order 7KHODVWWZRGLJLWVDUH5HOLHISUHVVXUHLQKXQGUHGV ([DPSOH SVLDOOUHOLHIVHWWLQJVDUHDW*30) -R\VWLFNKDQGOHZLOORSHUDWHERWKVSRROVXVLQJRQO\RQHOHYHUKDQGOH7KHWZRVSRROVFDQEHRSHUDWHGHLWKHULQGHSHQGHQWO\RUVLPXOWDQHRXVO\ GHSHQGLQJRQKDQGOHPRYHPHQW 0 Often used with no relief. Review application. CATV 41-03-16-03 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 18 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V41 RD5000 PRESSURE DROP, RELIEF CURVE AND STANDARD FEATURES STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRIKLJKWHQVLOH VWUHQJWKJUD\FDVWLURQ /RDGFKHFNRQHDFKVSRRO +DUGFKURPHSODWHGVSRRO 2SWLRQDO3RVLWLRQ)ORDWRQVWVSRRO 'LIIHUHQWLDOSRSSHWVW\OHUHOLHIDGMXVWDEOHIURP WRSVLDOVRDYDLODEOHLQORZSUHVVXUHYHUVLRQ DGMXVWDEOHIURPWRSVL 3RZHUEH\RQGDQGFORVHGFHQWHUFDSDELOLW\ 5HYHUVLEOHKDQGOH SPECIFICATIONS 3$5$//(/&,5&8,75'5' 0$;,08023(5$7,1*35(6685( ............ 36, 0$;,08023(5$7,1*7(03(5$785( .......... ) 0$;,0807$1.325735(6685( ............... 36, 5(&200(1'('6<67(0),/75$7,21....,62 )/2:5$7,1* ....................................*305' *305' *305' :(,*+7 ............................................... /%65' /%65' /%65' RD5000 RELIEF VALVE 110 SUS OIL AT 115°F RD5100 SINGLE SPOOL VALVE PRESSURE DROP VALUES 110 SUS OIL AT 115°F $ P-PSI INLET TO INLET TO A OR B OUTLET A OR B TO OUTLET 5 2 8 3 10 5 17 6 15 9 35 12 20 21 58 21 25 26 86 34 3000 VALVES PRESSURE (PSI) FLOW (GPM) RD5200 TWO SPOOL VALVE PRESSURE DROP VALUES 2500 2000 1500 1000 500 110 SUS OIL AT 115°F $ P-PSI FLOW (GPM) INLET TO OUTLET INLET TO WORK PORTS A OR B TO OUTLET C OR D TO TO OUTLET 5 3 11 2 2 10 8 22 8 5 15 16 38 15 11 20 28 57 27 19 25 44 83 43 29 0 5 10 15 20 25 FLOW (GPM) PARALLEL CIRCUIT VALVES %RWK WKH 5' 7ZR6SRRO DQG 5' 7KUHH6SRRO 9DOYHVDUHSDUDOOHOFLUFXLWYDOYHV:KHQDQ\RQHRIWKHVSRROV LV VKLIWHG LW EORFNV RII WKH RSHQ FHQWHU SDVVDJH WKUX WKH YDOYH7KHRLOWKHQÁRZVLQWRWKHSDUDOOHOFLUFXLWFRUHPDNLQJ RLO DYDLODEOH WR DOO VSRROV ,I PRUH WKDQ RQH VSRRO LV IXOO\ VKLIWHGWKHQRLOZLOOJRWRWKHVSRROZLWKWKHORZHVWSUHVVXUH UHTXLUHPHQWV+RZHYHULWLVSRVVLEOHWRPHWHUWKHÁRZWRWKH VSRROZLWKWKHOHDVWORDGDQGSRZHUWZRXQHTXDOORDGV OPEN CENTER PASSAGE LOAD CHECK PARALLEL CIRCUIT CORE RD5300 THREE SPOOL VALVE PRESSURE DROP VALUES B D F C E 110 SUS OIL AT 115°F $ P-PSI FLOW (GPM) INLET TO OUTLET INLET TO A OR B INLET TO C OR D INLET TO E OR F A OR B TO OUTLET C OR D TO OUTLET E OR F TO OUTLET 5 2 9 9 11 4 3 2 10 10 18 20 25 14 9 6 15 22 33 41 49 32 22 13 20 37 56 68 78 51 36 21 25 58 83 101 118 76 55 32 9 P A T CONVERSION PLUG 7KHDERYHGUDZLQJVKRZV DV\PEROIRUD7KUHH6SRRO9DOYH 0RGHO1XPEHU5'&&&$$$$% 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 42-07-13-02 RD5000 ORDERING INFORMATION STANDARD VALVES AVAILABLE:$OOVWDQGDUGYDOYHVKDYHHQGLQOHWDQGRXWOHWORFDWLRQVSRZHUEH\RQG FRQYHUVLRQSOXJFRPSOHWHKDQGOHDVVHPEOLHVDQGDGMXVWDEOHGLIIHUHQWLDOSRSSHWUHOLHI SPOOL TYPE VALVE PART NUMBER 3 POSITION 4 WAY2 FLOAT SPOOL1 RD516GG5A4B1 3 POSITION 4 WAY DETENTED3 2nd SPOOL CONFIG. 3rd SPOOL CONFIG. 3 POSITION 4 WAY2 3 POSITION 4 WAY2 IN/OUT PORT SIZE X RD516CA5A4B1 X RD515GG5A4B1 X RD515CA5A4B1 X RD515CB5A4B1 X RD526GCGA5A4B1 X RD526CCAA5A4B1 X RD536GCCGAA5A4B1 X RD536CCCAAA5A4B1 X WORK PORT SIZE #12 SAE RELIEF SETTING #12 SAE #10 SAE X X 2000 PSI @ 10 GPM X X 2000 PSI @ 10 GPM X X 2000 PSI @ 10 GPM X X 2000 PSI @ 10 GPM X X 2000 PSI @ 10 GPM X X X 2000 PSI @ 10 GPM X X X 2000 PSI @ 10 GPM X X X X 2000 PSI @ 10 GPM X X X X 2000 PSI @ 10 GPM )RXUSRVLWLRQIRXUZD\WDQGHPFHQWHUGHWHQWHG´LQµWKHÁRDWSRVLWLRQ6SULQJFHQWHUWRQHXWUDOIURPZRUNSRVLWLRQV :RUNSRUWVEORFNHGLQQHXWUDO 7DQGHPFHQWHU6SULQJFHQWHUWRQHXWUDOIURPZRUNSRVLWLRQV:RUNSRUWVEORFNHGLQQHXWUDO 7DQGHPFHQWHUSRVLWLRQGHWHQW:RUNSRUWVEORFNHGLQQHXWUDO MISC. AND FIELD CONVERSION KITS FOR MODEL RD-5000 VALVES 0$75,; &2'( $ % & 1 3 % & ) 635,1*&(17(5.,7 326,7,21'(7(17.,7 )5,&7,21'(7(17.,7 326,7,21'(7(176322/ 287:635,1*&(17(5 326,7,21'(7(17 :635,1*&(17(5.,7 &219(56,213/8* 32:(5%(<21'3/8* 137) 32:(5%(<21'3/8* 6$( ' 5 B B POWER BEYOND P SYMBOL RD516CA5A4C1 CATV 43-07-13-02 A 0$75,; &2'( T 125(/,()3/8* /2:35(6685($'-867$%/( 5(/,()&$57,'*( +,*+35(6685($'-867$%/( 5(/,()&$575,'*( &/26('&(17(5 &219(56,213/8* /2$'&+(&..,7 635,1*&(17(5:,7+ 0,&526:,7&+.,7 +$1'/(+$5':$5(.,7 5(/,()6+,0$662570(17 SYMBOL RD526CCAA5A4C1 POWER BEYOND A C * + B D P 0$75,; &2'( T 527$5<+$1'/(.,7 +$1'/(&/(9,6 5'6($/.,7 5'6($/.,7 5'6($/.,7 675$,*+7-2<67,&. +$1'/(.,7 %(17-2<67,&. +$1'/(3$576 )/2$7+$5':$5(.,7 $872&<&/(6($/.,7 $,56+,)7.,7 D F POWER BEYOND P A SYMBOL RD536CCCAAA5A4C1 C 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 18 & 19 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING E T V43 VALVES 1st SPOOL CONFIGURATION RD-5000 SERIES STANDARD AND SPECIAL FEATURE DESCRIPTIONS TWO SPOOL “JOYSTICK” HANDLE 12 STANDARD SPOOL ATTACHMENTS CONVERSION PLUG ALLOWS ADDITION OF POWER BEYOND PORT OUTLET RETURN CORE. OIL FLOWS AROUND SPOOL TO OUTLET SPRING CENTER 7KLVKDQGOHZLOORSHUDWHERWKVSRROV XVLQJRQO\RQHOHYHUKDQGOH7KH WZRVSRROVFDQEHRSHUDWHGHLWKHU LQGHSHQGHQWO\RUVLPXOWDQHRXVO\ GHSHQGLQJRQKDQGOHPRYHPHQW TANDEM CENTER SPOOL FLOAT DETENT FLOAT SPOOL 4 STANDARD SPOOLS WORK PORT "B" CORE WORK PORT "A" CORE DIFFERENTIAL POPPET RELIEF INLET "POWER" CORES FROM LOAD CHECK 7KHDERYHGUDZLQJVKRZVDVHFWLRQYLHZRIDVSRROYDOYH0RGHO5'*&*$$% 7KLVLVVKRZQDVDUHSUHVHQWDWLYHYDOYHPRGHO2WKHUPRGHOVZLOOGLIIHULQDSSHDUDQFH VALVES LOAD CHECK: 7KH ORDG FKHFN IHDWXUH LV VWDQGDUG RQ DOO 5' VHULHV YDOYHV (DFK VSRRO KDV D VHSDUDWH ORDG FKHFN 7KH ORDG FKHFN ZLOO SUHYHQW WKH IDOO RI D F\OLQGHU DV WKH VSRRO LV VKLIWHG ,W DOVR SUHYHQWV WKH EDFNÁRZ RI RLOIURPWKHZRUNSRUWWRWKHLQOHW$VVKRZQ EHORZ WKH SXPS PXVW EXLOG XS HQRXJK SUHVVXUH WR RYHUFRPH WKH SUHVVXUH RQ WKH ZRUNSRUWFDXVHGE\WKHZHLJKWRIWKHORDG EHIRUHWKHF\OLQGHUFDQPRYH Please noteWKDWWKHORDGFKHFNKDVQRWKLQJ WRGRZLWKKRZZHOOWKHYDOYHZLOOKROGXSD F\OLQGHUZLWKWKHVSRROLQQHXWUDO7KHORDG FKHFN LV IXQFWLRQDO RQO\ ZKHQ WKH VSRRO LV VKLIWHG CYLINDER LOAD CHECK POPPET WORK PORT "A" SPOOL SHIFTED FULLY "OUT" OIL FROM PUMP 7KHDERYHGUDZLQJVKRZVDVHFWLRQYLHZWKUXZRUN SRUWVRID5'6LQJOH6SRRO9DOYH V44 7KH 6WDQGDUG 5' 6HULHV 9DOYHV DUH RSHQ FHQWHU W\SH YDOYHV )RURSHQFHQWHUYDOYHVWKHK\GUDXOLFRLOLVGLUHFWHGIURPWKHLQOHWWRWKH RXWOHWRUSRZHUEH\RQGWKURXJKWKHRSHQFHQWHUSDVVDJHZKHQWKH VSRROVDUHLQQHXWUDO0RYLQJRQHRUPRUHVSRROVFORVHVRIIWKHRSHQ FHQWHUSDVVDJHDQGGLUHFWVRLOWRWKHZRUNSRUWV 2SHQ FHQWHU V\VWHPV PRVW RIWHQ FRQWDLQ À[HG GLVSODFHPHQW SXPSV 7KH30&K\GUDXOLF372SXPSVDUHÀ[HGGLVSODFHPHQWJHDUSXPSV 7KHPD[LPXPSUHVVXUHLQDQRSHQFHQWHUV\VWHPLVFRQWUROOHGE\D UHOLHIYDOYH7KH5'VHULHVYDOYHVKDYHDEXLOWLQUHOLHIYDOYHIRU WKLVSXUSRVH 5'6HULHVVSRRORSWLRQV$&(DQG*DUHDOORSHQFHQWHUVSRROV ZKHQXVHGZLWKSRZHUEH\RQGRSWLRQV$%&DQG) CLOSED CENTER APPLICATIONS: LOAD WORK PORT "B" OPEN CENTER APPLICATIONS: 5'6HULHV9DOYHVDUHDYDLODEOHDVFORVHGFHQWHUW\SHYDOYHV)RU FORVHGFHQWHUYDOYHVWKHRLOWKURXJKWKHRSHQFHQWHUSDVVDJHLVEORFNHG ZKHQWKHVSRROVDUHLQQHXWUDO &ORVHG FHQWHU V\VWHPV RIWHQ XVH D YDULDEOH GLVSODFHPHQW SUHVVXUH FRPSHQVDWHGSXPS:KHQWKLVW\SHRISXPSLVXVHGLQDFORVHGFHQWHU V\VWHPWKHV\VWHPSUHVVXUHLVFRQWUROOHGE\WKHSUHVVXUHFRPSHQVDWRU :KHQ WKH VSRROV RI 5' VHULHV YDOYH DUH LQ QHXWUDO V\VWHP SUHVVXUHLVPDLQWDLQHGDWWKHLQOHWRIWKHYDOYH)RUWKLVUHDVRQDUHOLHILV QRUPDOO\QRWUHTXLUHGRUPXVWEHVHWDWDKLJKHUSUHVVXUHWKDQWKHSXPS FRPSHQVDWRU5'6HULHVVSRRORSWLRQV&(DQG*DUHFRQYHUWHG WRFORVHGFHQWHUE\LQVWDOOLQJDFORVHGFHQWHUFRQYHUVLRQSOXJSRZHU EH\RQGRSWLRQ' 3/($6(127(WKDWWKLVFORVHGFHQWHURSWLRQGRHVQRWSURYLGHIRUWKH GUDLQRIIRIVWDQGE\VSRROOHDNDJH7KLVFDQDOORZDYHU\VPDOODPRXQW RIRLOWRHQWHUWKHZRUNSRUWVZKHQLQQHXWUDO 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 44-07-13-02 RD-5000 SERIES SPOOL OPTIONS B 3 WAY 3 POSITION OPEN CENTER OPTION A 7KLVVSRRORSWLRQLVXVHGWRFRQWURODVLQJOHDFWLQJF\OLQGHU RUDXQLGLUHFWLRQDOPRWRU,QQHXWUDOWKHZRUNSRUWLVEORFNHG DQGRLOJRHVWKURXJKWKHRSHQFHQWHUSDVVDJHWRWKHQH[W VSRRORIDPXOWLVSRROYDOYHRUWKHSRZHUEH\RQGRIDVLQJOH VSRROYDOYH7KH´$µSRUWLVSOXJJHGIRUWKLVRSWLRQ 4 WAY 3 POSITION OPEN CENTER MOTOR SPOOL OPTION E P-T LOAD CHECK 4 WAY 3 POSITION TANDEM CENTER OPTION C B A 7KLVVSRRORSWLRQLVXVHGWRFRQWURODGRXEOHDFWLQJF\OLQGHU RUDUHYHUVLEOHPRWRU,QQHXWUDOERWKRIWKHZRUNSRUWVDUH EORFNHGDQGRLOJRHVWKURXJKWKHRSHQFHQWHUSDVVDJHWR WKHQH[WVSRRORIDPXOWLVSRROYDOYHRUWKHSRZHUEH\RQGRI DVLQJOHVSRROYDOYH7KLVLVWKHPRVWSRSXODUVSRRORSWLRQ DQGLVXVHGRQPRVWPrince standard valves. B A 7KLVVSRRORSWLRQFDQEHXVHGWRFRQWURODELURWDWLRQDO PRWRURUDGRXEOHDFWLQJF\OLQGHU,QQHXWUDOWKHZRUN SRUWVDUHRSHQWRWKHUHWXUQ7KLVDOORZVDF\OLQGHU WRGULIWRUDPRWRUWRFRDVWWRDVWRS,QQHXWUDOWKHRLO JRHVWKURXJKWKHRSHQFHQWHUSDVVDJHWRWKHQH[W VSRRORIPXOWLVSRROYDOYHRUWKHSRZHUEH\RQGRID VLQJOHVSRROYDOYH P-T 4 WAY 3 POSITION CLOSED CENTER MOTOR SPOOL B A 7KLV RSWLRQ LV VLPLODU WR VSRRO RSWLRQ ( H[FHSW LQ QHXWUDO WKH RSHQ FHQWHU SDVVDJH LV EORFNHG 7KLV IXQFWLRQ LV DFKLHYHG E\ XVLQJ VSRRO RSWLRQ ( ZLWK D FORVHG FHQWHU FRQYHUVLRQ SOXJ 3RZHU EH\RQG RSWLRQ' P-T P-T 4 WAY 4 POSITION OPEN CENTER FLOAT SPOOL OPTION G 4 WAY 3 POSITION CLOSED CENTER B A 7KLVVSRRORSWLRQLVVLPLODUWRVSRRORSWLRQ&DERYHH[FHSW LQQHXWUDOWKHRSHQFHQWHUSDVVDJHLVEORFNHG7KLVIXQFWLRQ LVDFKLHYHGE\XVLQJVSRRORSWLRQ&ZLWKDFORVHGFHQWHU FRQYHUVLRQSOXJ3RZHUEH\RQGRSWLRQ' P-T 7KLVRSWLRQLVWKHVDPHDVVSRRORSWLRQ&ZD\SRVLWLRQ WDQGHP FHQWHU ZLWK DQ DGGHG IRXUWK ´ÁRDWµ SRVLWLRQ ,Q QHXWUDO WKH ZRUN SRUWV DUH EORFNHG WKLV ZLOO KROG XS D F\OLQGHUDQGWKHRLOJRHVWKURXJKWKHRSHQFHQWHUSDVVDJH WRWKHQH[WVSRRORUSRZHUEH\RQG,QWKHÁRDWSRVLWLRQWKH ZRUNSRUWVDUHRSHQWRWKHUHWXUQWKLVZLOODOORZDF\OLQGHU WRGULIWRU´ÁRDWµDQGWKHRLOJRHVWRQH[WVSRRORUSRZHU EH\RQG7KHÁRDWSRVLWLRQLVUHDFKHGE\SXVKLQJWKHVSRRO DVIDUDVLWZLOOJRDQG,VKHOGLQSODFHE\DGHWHQW7KLV RSWLRQPXVWEHRUGHUHGZLWKVSRRODFWLRQRSWLRQ* B A P-T RD-5000 SERIES SPOOL ATTACHMENT OPTIONS 7KLVRSWLRQKDVSRVLWLRQVDQGDVSULQJWKDWUHWXUQV WKH VSRRO WR QHXWUDO ZKHQ WKH KDQGOH LV UHOHDVHG 7KLVRSWLRQLVFRQVLGHUHGVWDQGDUGRQPDQ\3ULQFH YDOYHPRGHOV 7KLVRSWLRQFDQEHFRQYHUWHGLQWKHÀHOGWRSRVLWLRQ GHWHQWE\RUGHULQJ.LW,WFDQEHFRQYHUWHG WRIULFWLRQGHWHQWE\RUGHULQJ.LW 3 POSITION DETENT OPTION B 7KLV RSWLRQ SURYLGHV WKUHH GHWHQWHG SRVLWLRQV 7KH VSRROZLOOUHPDLQLQDQ\RIWKHWKUHHSRVLWLRQVLQZKLFK LWLVPDQXDOO\SODFHG1RFHQWHULQJVSULQJLVSURYLGHG 1RWH7KLVRSWLRQGRHVQRWSRVLWLYHO\ORFNWKHVSRRO LQ SODFH ([FHVVLYH YLEUDWLRQ RU VKRFN ORDGV PD\ HIIHFWRSHUDWLRQ 7KLV RSWLRQ FDQ EH FRQYHUWHG LQ WKH ÀHOG WR VSULQJ FHQWHUE\RUGHULQJ.LW,WFDQEHFRQYHUWHG WRIULFWLRQGHWHQWE\RUGHULQJ.LW 670300001 670500004 7KLV RSWLRQ FDQ EH FRQYHUWHG LQ WKH ÀHOG WR VSULQJ FHQWHUE\RUGHULQJ.LWDQGWRSRVLWLRQ GHWHQWE\RUGHULQJ.LW 4 POSITION SPRING CENTER TO NEUTRAL DETENT SPOOL ‘IN’ FOR FLOAT POSITION OPTION G CATV 45-07-13-02 670300002 (2) 170003018 (4) 670700008 PRESSURE RELEASE DETENT, DETENT SPOOL ‘OUT ONLY, SPRING CENTER TO NEUTRAL OPTION E 7KLVRSWLRQSURYLGHVDSUHVVXUHUHOHDVHGHWHQWIRU WKHVSRRO¶2XW·SRVLWLRQ:KHQWKHVSRROLVPDQXDOO\ SODFHGLQWKHGHWHQWSRVLWLRQRLOLVGLUHFWHGWRWKH¶%· ZRUN SRUW WKH SRUW DZD\ IURP WKH KDQGOH :KHQ WKH SUHVVXUH LQ WKH ¶%· SRUW UHDFKHV D SUHVHW OHYHO WKHGHWHQWZLOOUHOHDVHDQGWKHVSRROZLOOFHQWHU7KH GHWHQW UHOHDVH SUHVVXUH LV IDFWRU\ VHW DW SVL 7KLVSUHVVXUHLVDGMXVWDEOHIURPWRSVL 7KHGHWHQWUHOHDVHSUHVVXUHLVDGMXVWHGE\WXUQLQJWKH DGMXVWLQJVFUHZFORFNZLVHWRLQFUHDVHWKHSUHVVXUH DQGFRXQWHUFORFNZLVHWRGHFUHDVHWKHSUHVVXUH7KH VSRROLVVSULQJFHQWHUHGWRQHXWUDOIURPWKHVSRRO¶,Q· SRVLWLRQ7KLVRSWLRQFDQEHXVHGZLWKVSRRORSWLRQV $&RU( DETENT RELEASE PRESSURE ADJUSTING SCREW 7KLV RSWLRQ can not EH DGGHG WR D YDOYH LQ WKH ÀHOG 670700002 230009009 (4) 670700008 230009009 (4) 670700007 670500005 670300002 (2) 671200002 670500005 670300002 (2) 170003018 (4) 670700001 230009009 (4) 7KLVDWWDFKPHQW,VXVHGZLWKVSRRORSWLRQ¶*·7KLV RSWLRQSURYLGHVIRUVSULQJFHQWHUWRQHXWUDOIURPHLWKHU ZRUN SRVLWLRQ ,W DOVR SURYLGHV D WK SRVLWLRQ ÁRDW GHWHQW 7KH ÁRDW GHWHQW LV UHDFKHG E\ SXVKLQJ WKH VSRROLQDVIDUDVLWZLOOJR,QWKHÁRDWSRVLWLRQERWK ZRUNSRUWVDUHRSHQWRUHWXUQ7KLVDOORZVDF\OLQGHU 670700003 WRGULIWRU´ÁRDWµ 7KLVRSWLRQLVDYDLODEOHRQO\ZLWKVSRRORSWLRQ¶*·DQG FDQQRWEHDGGHGWRDYDOYHLQWKHÀHOG 670500005 170003008 (4) 170003008 (4) FRICTION DETENT OPTION C 7KLVRSWLRQSURYLGHVIRUDGHWHQWLQWKHQHXWUDOSRVLWLRQ RQO\$VWKHVSRROLVPDQXDOO\PRYHGDZD\IURPWKH QHXWUDOSRVLWLRQLWZLOOEHKHOGLQSODFHE\WKHIULFWLRQRI WKHGHWHQWEDOOVRQWKHGHWHQWVOHHYH1RWH%HFDXVH WKHVSRROLVKHOGLQSODFHE\IULFWLRQRQO\H[FHVVLYH YLEUDWLRQPD\FDXVHVSRROWRPRYHZKHQQRWLQWKH QHXWUDOGHWHQWHGSRVLWLRQ 671400001 670500003 170003007 671400011 VALVES 3 POSITION SPRING CENTER TO NEUTRAL OPTION A 671200002 670500005 170003019 (4) 671200001 670300003 670500003 670500007 670500008 670500009 PRESSURE RELEASE DETENT, DETENT SPOOL ‘IN’ AND ‘OUT’ SPRING CENTER TO NEUTRAL OPTION F 7KLVRSWLRQLVVLPLODUWRRSWLRQ¶(·DERYHH[FHSWWKH SUHVVXUHUHOHDVHGHWHQWIXQFWLRQLVRQERWKWKHVSRRO ¶,Q· DQG ¶2XW· SRVLWLRQV7KLV RSWLRQ LV DYDLODEOH RQ 5'YDOYHDQGQXPEHUVSRRORI5'DQG 5'YDOYHV 7KLV RSWLRQ FDQ EH XVHG ZLWK VSRRO RSWLRQV & RU (7KLVRSWLRQcan notEHDGGHGWRDYDOYHLQWKH ÀHOG 1 POSITION DETENT SPOOL ‘OUT’ SPRING CENTER TO NEUTRAL OPTION N 7KLVRSWLRQXVHVWKHVDPHSDUWVDVRSWLRQ(DERYHEXWLVQRWSUHVVXUHUHOHDVHG 7KHKDQGOHPXVWEHPDQXDOO\UHPRYHGIURPWKHGHWHQWSRVLWLRQ7KHGHWHQWKROGLQJ IRUFHLVDGMXVWDEOH 2 POSITION DETENT SPOOL ‘IN’ AND ‘OUT’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ÀHOG POWER BEYOND NOT PROVIDED OPTION A 7KLV RSWLRQ SURYLGHV GHWHQWHG SRVLWLRQ QHXWUDO DQG VSRRORXW7KHVSRROLVSUHYHQWHGIURPJRLQJLQWRWKH ´VSRROLQµSRVLWLRQ7KHVSRROZLOOUHPDLQLQWKHGHWHQWHG SRVLWLRQLQZKLFKLWLVPDQXDOO\SODFHG7KHRSWLRQGRHV QRW SRVLWLYHO\ ORFN WKH VSRRO LQ SODFH DQG H[FHVVLYH YLEUDWLRQRUVKRFNORDGVPD\DIIHFWWKHRSHUDWLRQ7KH WKUHHSRVLWLRQGHWHQWNLWFDQEHFRQYHUWHGLQWRWKLVRSWLRQ E\RUGHULQJSDUW1R RETURN CORE 7KLV RSWLRQ SURYLGHV DQ RXWOHW OPEN END OUTLET RQO\ ZLWK QR SURYLVLRQ IRU SRZHU CENTER CORE (TO TANK) EH\RQG7KLVRSWLRQFDQEHXVHG ZLWKDQ\RSHQFHQWHUVSRROVZKHUH WKHUH LV QR QHHG IRU D SRZHU EH\RQG SRU W 7KH HQG RXWOHW RETURN VKRZQ DW ULJKW LV FRQVLGHUHG CORE VWDQGDUGEXWDWRSRUERWWRPRXWOHW FDQDOVREHVSHFLÀHG :KHQDOOWKHYDOYHVVSRROVDUHLQQHXWUDORLOJRHVWKURXJKWKH RSHQFHQWHUFRUHWRWKHRXWOHW 7KLVRSWLRQFDQQRWEHFRQYHUWHGLQWKHÀHOGWRKDYHSRZHUEH\RQG ,WDOVRFDQQRWEHFRQYHUWHGIURPRSHQWRFORVHGFHQWHU RETURN CORE END OUTLET (TO TANK) 7KLV RSWLRQ LV VLPLODU LQ IXQFWLRQ OPEN CENTER WR 2SWLRQ ¶$· DERYH H[FHSW WKH CORE FRQYHUVLRQ SOXJ LV LQVWDOOHG LQ WKH SRZHU EH\RQG ORFDWLRQ DQG WKH HQG RXWOHW LV UHORFDWHG 7KLV RSWLRQ VKRXOG EH XVHG ZLWK WKH RETURN CONVERSION RSHQ FHQWHU VSRRO RSWLRQV DQG CORE PLUG (660312003) DOORZVWKHYDOYHWREHFRQYHUWHGWR KDYHSRZHUEH\RQGIXQFWLRQRUEH FRQYHUWHGIURPRSHQWRFORVHGFHQWHU7KLVRSWLRQLVFRQVLGHUHG WKHPMC StandardSRZHUEH\RQGRSWLRQEHFDXVHRIWKHÁH[LELOLW\ LWDGGVWRWKHYDOYH :KHQDOOWKHYDOYHVSRROVDUHLQQHXWUDORLOJRHVWKURXJKRSHQ FHQWHUFRUHWRUHWXUQFRUHDQGWKHQWRRXWOHW 7RFRQYHUWDYDOYHLQWKHÀHOGWRKDYHSRZHUEH\RQGUHPRYH WKHFRQYHUVLRQSOXJDQGUHSODFHLWZLWKRQHRIWKHSRZHUEH\RQG SOXJVOLVWHG7RFRQYHUWYDOYHWRFORVHGFHQWHUUHSODFHFRQYHUVLRQ SOXJZLWKFORVHGFHQWHUSOXJ RETURN CORE END OUTLET (TO TANK) OPEN CENTER CORE POWER BEYOND 7KLV RSWLRQ SURYLGHV ERWK DQ RXWOHW DQG PORT (CONNECT TO DOWNSTREAM D SRZHU EH\RQG SRUW DOVR UHIHUUHG WR VALVE) DVDKLJKSUHVVXUHFDUU\RYHUSRUW7KLV RETURN DOORZV DQRWKHU YDOYH WR EH FRQQHFWHG CORE GRZQVWUHDP :KHQ DOO WKH VSRROV RI D 237,21&3OXJ1R 5'VHULHVYDOYHDUHLQQHXWUDOKLJK 237,21)3OXJ1R SUHVVXUH RLO FDQ JR WKURXJK WKH RSHQ FHQWHUFRUHDQGRXWWKHSRZHUEH\RQGSRUW WRWKHLQOHWRIGRZQVWUHDPYDOYH7KHGRZQVWUHDPYDOYHRQO\UHFHLYHVRLOZKHQ DOOVSRROVRIWKHÀUVWYDOYHDUHLQQHXWUDO7KLVRSWLRQPXVWEHXVHGZLWKRSHQ FHQWHUVSRROVDQGWKHRXWOHWRIYDOYHPXVWEHFRQQHFWHGWRWDQN ,IWKHSRZHUEH\RQGSRUWLVQRWXVHGRQDYDOYHLQDQRSHQFHQWHUV\VWHPWKH SRZHUEH\RQGSRUWPXVWEHFRQQHFWHGWRWDQNRUWKHSRZHUEH\RQGSOXJUHSODFHG ZLWKFRQYHUVLRQSOXJ $YDOYHZLWKSRZHUEH\RQGFDQEHFRQYHUWHGWRFORVHGFHQWHUE\SOXJJLQJWKH SRZHUEH\RQGSRUWRULQVWDOOLQJFORVHGFHQWHUSOXJ CLOSED CENTER CONVERSION PLUG INSTALLED OPTION D RETURN CORE END OUTLET 7KLV RSWLRQ FRQYHUWV DQ RWKHUZLVH RSHQ (TO TANK) FHQWHU YDOYH WR FORVHG FHQWHU RSHUDWLRQ OPEN 7KH RSHQ FHQWHU FRUH LV EORFNHG E\ WKH CENTER CORE FRQYHUVLRQSOXJ2LOFDQQRWSDVVWKURXJKWKH BLOCKED YDOYHZKHQWKHVSRROVDUHLQQHXWUDO&ORVHG FHQWHUV\VWHPVDUHQRUPDOO\DVVRFLDWHGZLWK YDULDEOH GLVSODFHPHQW SXPSV RU DQ\ RWKHU RETURN CLOSED CENTER V\VWHP ZKHUH WKH SXPS ÁRZ LV XQORDGHG CORE CONVERSION PLUG ZKHQV\VWHPSUHVVXUHLVUHDFKHG (660312005) 1RWH,IWKHFORVHGFHQWHUSOXJLVLQVWDOOHGLQ DYDOYHWKDWKDVDUHOLHILWPD\EHQHFHVVDU\WRLQVWDOOWKHQRUHOLHISOXJRUDGMXVW WKHUHOLHISUHVVXUHDERYHWKHFRPSHQVDWRUVHWWLQJ $OVRWKLVFORVHGFHQWHURSWLRQGRHVQRWSURYLGHIRUWKHGUDLQRIIRIVWDQGE\VSRRO OHDNDJH7KLVFDQDOORZDYHU\VPDOODPRXQWRIRLOWRHQWHUWKHZRUNSRUWVZKHQ LQQHXWUDO RD-5000 2 SPOOL SPECIAL APPLICATION VALVE 7KLVYDOYHLVDPRGLÀHG5'WZRVSRROYDOYHWKDWFDQEHXVHGWRDXWRPDWLFDOO\ F\FOHDK\GUDXOLFF\OLQGHU7KHVSRROVDQGWKHYDOYHERG\KDYHEHHQPRGLÀHGWR SURYLGHWKLVIXQFWLRQ%RWKVSRROVKDYHWKHSUHVVXUHUHOHDVHGHWHQWVSRRODWWDFKPHQW 7KHYDOYHLVVKRZQFRQQHFWHGWRDF\OLQGHULQWKHVNHWFKEHORZ7KH´%µSRUWLV FRQQHFWHGWRWKHEDVHRIWKHF\OLQGHU7KH´$µDQG´'µSRUWVDUHWLHGWRJHWKHUDQG FRQQHFWHGWRWKHURGHQGRIWKHF\OLQGHU7KH´&µSRUWLVSOXJJHG$WWKHEHJLQQLQJ RIWKHF\FOHWKHF\OLQGHULVIXOO\UHWUDFWHG7REHJLQWKHF\FOHERWKKDQGOHVDUHSXOOHG EDFN2LOLVGLUHFWHGWRWKH´%µSRUWDQGWKHF\OLQGHUZLOOH[WHQGXQWLOLWUHDFKHVWKHHQG RILWVVWURNH$WWKLVSRLQWWKHSUHVVXUHZLOOEXLOGWRWKHGHWHQWUHOHDVHSUHVVXUHDQG WKHÀUVWVSRROZLOOFHQWHUWRQHXWUDO1RZWKHRLOZLOOJRWKURXJKWKHRSHQFHQWHUFRUH WRWKHVHFRQGVSRRODQGLVGLUHFWHGRXWWKH´'µSRUWWRUHWUDFWWKHF\OLQGHU:KHQWKH F\OLQGHUUHDFKHVWKHIXOOUHWUDFWSRVLWLRQWKHSUHVVXUHZLOOEXLOGWRWKHGHWHQWUHOHDVH SUHVVXUHDQGWKHVHFRQGVSRROZLOOFHQWHUWRQHXWUDO7KLVFRPSOHWHVWKHF\FOH7R EHJLQWKHQH[WF\FOHERWKKDQGOHVDUHDJDLQPDQXDOO\SXOOHGEDFN3OHDVHQRWHWKLV YDOYHGRHVQRWKDYHWKHORDGFKHFNIHDWXUHRIWKHVWDQGDUG5'YDOYH$OVRWKH ´%µSRUWLVRSHQWRWDQNLQQHXWUDO0D[LPXPGHWHQWSUHVVXUHVHWWLQJLV36, 9 Model Number RD525MMEE5A4B1 D B BYD “AUTO-CYCLE” TWO SPOOL VALVE OUT VALVES CONVERSION PLUG INSTALLED OPTION B POWER BEYOND PLUG INSTALLED OPTION C 3/4 NPTF POWER BEYOND PORT OPTION F #12 SAE POWER BEYOND PORT C A IN 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 46-07-13-02 5'3523257,21$/23(5$7259$/9( 5'6(5,(69$/9( WITH PROPORTIONAL OPERATORS B The RD5000 valve is available with proportional solenoid operators. The valve will allow controlled starts and stops of the ZRUNSRUWÁRZDVZHOODVFRQWURORIWKHZRUNSRUWÁRZUDWHRYHU a limited metered range. Pilot pressure to initiate spool shift is provided internally by means of a pressure build-up cartridge in the power beyond port. Once the spool shift is initiated, load induced pressure is required to regulate the spool position and ÁRZ%\LQFUHDVLQJWKHFXUUHQWWKURXJKRQHRIWKHVROHQRLGV increasing pressure is applied to a spool end, causing the spool to shift against spring bias. Full spool shift is at approximately 1200 mA - 12 VDC (600 mA - 24 VDC). A OUT BYD IN HCI-PRINCE RD5000 Valve with Proportional Operators WORKPORT FLOW VS. AMPERAGE 35 WORK PORT FLOW (GPM) 30 GPM INLET FLOW 30 25 32° 20 GPM INLET FLOW 32° 20 15 10 GPM INLET FLOW 10 2.520 5 GPM INLET FLOW 8.413 5 0 50° 400 500 600 700 800 900 1000 1100 1200 .354 AMPERAGE (mA) 1.811 PIN 1 Thumb Control Joystick VALVES The RD5000 proportional operators are typically controlled with a thumb or handle control and a PWM control module. Prince offers a small thumb control joystick (671300076) and a larger handle control joystick (671300077). A PWM control module (671300075) that can be used in conjunction with these joysticks is also offered by Prince. The control module provides a performance enhancing dither to the current. The minimum and maximum current from the module can also be set to minimize WKHGHDGEDQGEHIRUHZRUNSRUWÁRZVWDUWVDQGWRPD[LPL]HWKHFRQWURO resolution. Additional controls are available. Please contact sales at Prince Manufacturing for additional information. The connector on the thumb joystick is a Molex #CGRID/SL (7 male pins). The connector on the handle joystick is a Deutsch #HD14-9-16P (9 male pins). The connector on the PWM control module is a Deutsch #DT04-8P (8 male pins). A harness is needed to connect the joystick, PWM module, and coils. 1.9 .83 2.464 Handle Control Joystick 4.53 PM Control Module RD51 MODEL NUMBER RD51 Single Spool PORT SIZE SPOOL TYPE 6 #12 SAE In/Out #10 SAE Work C 4 Way, 3 Position Tandem Center SPOOL ATTACHMENTS A 3 Position, Spring Center to Neutral * For other non-standard relief settings, please specify: * RD516CA5A4H–DP12H–25 The last two digits are relief pressure in hundreds (example: 25=2500 PSI). All relief settings are at 10 gpm & 105°F. ** Often used with no relief. Review application The RD5000 proportional operated valve is offered in two standard models as shown below. Additional options as well as two and three spool versions are available. Please contact sales at Prince Manufacturing Corp. for additional information RELIEF VALVE 1 No Relief 5 * Differential Poppet Adjustable 1500-3000 PSI Set at 2000 PSI INLET LOCATION A End OUTLET LOCATION 4 END POWER BEYOND H Open Center Pressure Build-up D ** Closed Center Conversion Plug Installed PROPORTIONAL SOLENOID COIL DP12Q 12VDC Dual Spades DP12L 12VDC Dual Lead Wires DP12H 12DVC DIN-43650 DP12D 12VDC Integral Deutsch DP24Q 24VDC Dual Spades DP24L 24VDC Dual Lead Wires DP24H 24VDC DIN-43650 RD516CA5A4H–DPxxx DP24D 24VDC Integral Deutsch RD516CA1A4D–DPxxx DP11H 110VAC DIN-43650 CATV-46.5-2-15-03 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V46.5 SOLENOID OPERATED RD5000 DIRECTIONAL CONTROL VALVE SPECIFICATIONS VALVES 0$;,08035(6685( ...............................36, 0$;,0807$1.35(6685( .......................36, 0$;,080)/2: .......................................... *30 0,1,080),/75$7,21 .......................... 0,&521 0$;,08023(5$7,1*7(03(5$785( .......) 6HHGUDZLQJVWKURXJKIRU VDPSOHELOOVRIPDWHULDOV The Solenoid Operated RD5000 Directional Control ValveDOORZVUHPRWHHOHFWULFDORQRIIRUPDQXDOFRQWURO7KLV IHDWXUHFDQEHLQVWDOOHGRQWKH5'5'RU5',WFDQEHLQVWDOOHGRQRQHRUDOOVSRROVRIWKH5'RU 5'7KLVRSWLRQFDQEHSXUFKDVHGDVNLWVDQGLQVWDOOHGE\FXVWRPHU&RPSOHWHYDOYHVDUHDYDLODEOHVSHFLDORUGHU RQO\PLQTW\&RQVXOW\RXUVDOHVUHSUHVHQWDWLYH ITEM 1 2 3 4 5 6 7 8 9 QTY 1 2 1 1 1 1 1 1 1 PART NUMBER 660150030 SEE CHART 660150037 660150033 660150035 660150036 660150046 660150047 SEE CHART DESCRIPTION BASE ACTUATOR KIT SOLENOID COIL END MANIFOLD KIT MID SECTION MANIFOLD KIT MANIFOLD TUBE KIT (SHORT) MANIFOLD TUBE KIT (LONG) PRES. RED. MAN. KIT (MULTI-SPOOL) PRES. RED. MAN. KIT (SINGLE-SPOOL) PRES. BUILD-UP CART. DESCRIPTION PRES, BUILD-UP CART. OPEN CENTER PRES. BUILD-UP POWER BEYOND CART (#12 SAE) 12 VDC LEAD WIRE COIL 12 VDC DOUBLE SPADE COIL 12 VDC WEATHER PACK 12 VDC DIN 43650 COIL 24 VDC LEAD WIRE COIL 24 VDC DOUBLE SPADE COIL 24 VDC DIN 43650 COIL 120 VAC CONDUIT COIL 120 VAC DIN 43650 COIL CATV 47-07-13-02 PART NUMBER 660312012 660312014 671302003 671322004 671302013 671302002 671302007 671322008 671302006 671302009 671302010 The Solenoid Operated RD5000FRQWDLQVWZRZD\ SRVLWLRQVROHQRLGFDUWULGJHYDOYHVDQGDSLORWRSHUDWHG SLVWRQDWWDFKHGWRWKHPDLQFRQWUROVSRRO:KHQERWK VROHQRLGVDUHGHHQHUJL]HGERWKVLGHVRIWKHSLORWSLVWRQ DUHRSHQWRWDQNSUHVVXUHDQGWKHVSRROUHPDLQVVSULQJ FHQWHUHG:KHQVROHQRLG$LVHQHUJL]HGSLORWSUHVVXUH LVDSSOLHGWRRQHVLGHRIWKHSLORWSLVWRQFDXVLQJWKH VSRROWRVKLIWIURPWKHQHXWUDOSRVLWLRQWRZRUNSRUW$ :KHQVROHQRLG´%µLVHQHUJL]HGSLORWSUHVVXUHLVDSSOLHG WRWKHRWKHUVLGHRIWKHSLORWSLVWRQFDXVLQJWKHVSRROWR VKLIWWRZRUNSRUW´%µ,QFDVHVZKHUHWKHSLORWSUHVVXUH LVSURYLGHGE\WKHLQOHWOLQHRU6$(SRUWRQYDOYHD ´3UHVVXUH%XLOG8S9DOYHµPXVWEHLQVWDOOHGLQWKHRXWOHW SRUW7ZRYHUVLRQVRIWKHSUHVVXUHEXLOGXSYDOYHDUH RIIHUHG7KHRSHQFHQWHUSUHVVXUHEXLOGXSYDOYHDQG WKHSRZHUEH\RQGSUHVVXUHEXLOGXSYDOYH%RWKYHU VLRQVVXSSO\36,SLORWSUHVVXUHWRWKHVROH QRLGDFWXDWRU:KHQUHPRWHSLORWLVXVHGWKHSUHVVXUH EXLOGXSLVQRWUHTXLUHG%HFDXVHWKHYDOYHLVLQWHUQDOO\ SLORWHGRYHUFHQWHURUOLJKWORDGVFDQEHDSUREOHP7KH LQOHWSUHVVXUHPXVWEHDWOHDVWSVLGXULQJRSHUDWLRQ 5HVWULFWRUVFDQEHDGGHGWRHOLPLQDWHWKLVSUREOHP 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 19 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 MODEL RD4100 SINGLE SPOOL MONO-BLOCK VALVE RD4100 SPECIFICATIONS 0$;,08023(5$7,1*35(6685( ............................. 36, 0$;,0807$1.35(6685( ........................................... 36, 0$;,08023(5$7,1*7(03(5$785( ........................... ) 5(&200(1'('6<67(0),/75$7,21 ........,62 )/2:5$7,1* ...................................................................*30 STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRIKLJKWHQVLOHVWUHQJWKJUD\ FDVWLURQ /RDGFKHFN +DUGFKURPHSODWHGVSRRO $GMXVWDEOHFDUWULGJHUHOLHI 2SHQFHQWHUFORVHGFHQWHUDQGSRZHUEH\RQGDYDLODEOH )RUXVHZLWKV\VWHPÁRZVXSWRJSP )RUXVHZLWKV\VWHPSUHVVXUHVXSWR36, 2SWLRQDOWRSLQOHWRXWOHWSRUWORFDWLRQV RD41 VALVES MODEL NUMBER PORT SIZE SPOOL TYPE SPOOL ACTIONS RELIEF VALVE RD41 Single Spool 2 #10 SAE in & out #8 SAE work A 3 Way 3 Position Tandem Center A Spring Center 1 No Relief B 3 Position Detent 4 Direct Acting Adjustable 500-1500 PSI Set at 1000 PSI B 4 Way 3 Position Tandem Center *RD412BA5A1A1-25 C Friction Detent C 4 Way 3 Position Open Center Motor Spool THE LAST TWO DIGITS ARE RELIEF PRESSURE IN HUNDREDS. EX: 25=2500 psi. ALL RELIEFS ARE SET AT 10 GPM & 105°F ** OFTEN USED WITH NO RELIEF. REVIEW APPLICATION. D 4 Way 4 Position Tandem Center Float Spool INLET LOCATION A End B Top OUTLET LOCATION 1 End W/Power Beyond Option A 2 Top W/Power Beyond Options B, C & D 5 Direct Acting Adjustable 1500-3000 PSI Set at 2000 PSI D Float Detent See SVW Section for Additional Spool Actions POWER BEYOND A Not Provided B Conversion Plug Installed C Power Beyond Plug Installed with #8 SAE D** Closed Center Conversion Plug Installed For other relief settings please specify* HANDLE 1 Std. Lever Handle 2 Less Handle Only 3 Less Complete Handle Assembly 5 Tang Spool End Only 6 Clevis Spool End Only 11 Enclosed Handle STANDARD VALVES AVAILABLE: All standard valves have a load check, a complete lever handle assembly, and an adjustable relief, see table below for settings. For other relief settings, please specify. SPOOL ACTION SPOOL TYPE VALVE PART NUMBER SPRING CENTER 3 POSITION TO DETENT NEUTRAL FLOAT DETENT IN/OUT PORT SIZE WORK PORT SIZE RELIEF SETTING CONVERTIBLE FROM OPEN CENTER TO CLOSED CENTER RD412BA5A1A1 X X #10 SAE #8 SAE 2000 PSI AT 10 GPM NO RD412BA5A2B1 X X #10 SAE #8 SAE 2000 PSI AT 10 GPM YES RD412BB5A2B1 X #10 SAE #8 SAE 2000 PSI AT 10 GPM YES #10 SAE #8 SAE 2000 PSI AT 10 GPM YES #10 SAE #8 SAE 2000 PSI AT 10 GPM YES RD412CA5A2B1 RD412DD5A2B1 9 4 WAY 4 WAY 4 WAY 3 POSITION 4 POSITION 3 POSITION FLOAT MOTOR X X X X X X 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 19 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 48-07-13-02 RD-4100 KITS, RELIEF CURVE, & PRESSURE DROP RD-4100 RELIEF VALVE CURVES 3000 RD-4100 SINGLE SPOOL PRESSURE DROP 2500 FLOW (GPM) 110 SUS OIL AT 115°F $ P-PSI INLET TO INLET TO A OR B OUTLET A OR B TO OUTLET 5 3 10 3 10 11 42 12 15 26 85 32 PSI 2000 1500 1000 0 NO RELIEF PLUG 2 4 6 8 GPM 10 12 14 16 OPEN CENTER CONVERSION PLUG SPRING CENTER FLOAT DETENT HIGH PRESSURE RELIEF CART. VALVES POWER BEYOND CART. (#8 SAE) CLOSED CENTER PLUG 3.70 POWER BEYOND OPTIONS 2.48 OUTLET PORT LOCATION .80 OUT .343 DIA. (2) PLEASE NOTE: This closed center option does not provide for the drain off of standby spool leakage. This can allow a very small amount of oil to enter the work ports when in neutral. SPRING CENTER WORK PORTS A & B 1.64 1.40 IN B A 3.00 2.48 3.75 3 POSITION DETENT .56 5.34 9.65 STANDARD INLET PORT LOCATION 2.65 1.12 7.34 8.84 12.41 CATV 49-07-13-02 3$57180%(5 '(6&5,37,21 6($/.,7 /2$'&+(&..,7 32:(5%(<21'6($/.,7 635,1*&(17(5.,7 326,7,21'(7(17.,7 326,7,21'(7(17.,7 635,1*&(17(5)/2$7.,7 &203/(7(+$1'/(.,7 +$1'/(.,7 &/(9,668%$66< 3,1.,7 5(/,()3/8* 5(/,()&$5736, 5(/,()&$5736, 23(1&(17(53/8* 32:(5%(<21'&$576$( &/26('&(17(53/8* 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 17, 19 & 21 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 MODEL LV MONO-BLOCK Directional Control Valves Especially Suited for Front Loader Market LVS Series Circuit 7RS3RUWHGRU6HPL5HDU3RUWHG VALVES LVT Parallel Circuit 7RS3RUWHG LVR Parallel Circuit 5HDU3RUWHG 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 50-07-13-02 MODEL LVS SERIES LOADER VALVE LVS SPECIFICATIONS SERIES CIRCUIT (multifunction operation, simultaneous operation of both boom and bucket) MAXIMUM OPERATING PRESSURE ................................. 3000 PSI MAXIMUM TANK PRESSURE ............................................... 500 PSI MAXIMUM OPERATING TEMPERATURE ............................... ) RECOMMENDED SYSTEM FILTRATION ............,62 FLOW RATING .......................................................................11 GPM WEIGHT .................................................................................. 18.5lbs STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRIKLJKWHQVLOHVWUHQJWKJUD\FDVWLURQ /RDGFKHFNRQHDFKVSRRO +DUGFKURPHSODWHGVSRROV 1RIDFHVHDOVRQVSRROV $GMXVWDEOHFDUWULGJHUHOLHI 3RZHUEH\RQGDYDLODEOH 3RVLWLRQ6HULHV)ORDW6SRROIRUORDGHUERRP 3RVLWLRQ5HJHQ6SRROIRUORDGHUEXFNHW 0ROGHGUXEEHUERRW 3DWHQWHGGXDOVSRROORFNMR\VWLFNDYDLODEOH LVS MODEL NUMBER INLET & TANK PORT OPTION WORK PORT OPTION SPOOL & ACTION RELIEF OPTIONS POWER BEYOND OPTIONS HANDLE OPTIONS LVS Two spool loader valve Series circuit 1 Rear inlet & tank port #8 SAE ORB A A & C work ports on top and B & D work ports on rear, #6 SAE ORB GR Standard A-B 4 way 4 position float, spring center with float detent C-D 4 way 4 position selective regen, spring center with soft stop 1 No Relief A Standard open center (field convertible to #8 SAE ORB top power beyond) 1 Joystick & boot w/ dual spool lock, mounting feet down/to rear *LVS1AGR5B1-25 THE LAST TWO DIGITS ARE THE RELIEF SETTING IN HUNDREDS. EX: 25=2500 PSI @ 10 GPM ALL RELIEFS ARE SET AT 10 GPM. C Work ports on top, #8 SAE ORB B #8 SAE rear power beyond 5 Standard: Adjustable direct acting relief 1500-3000 PSI (set at 2000 PSI) GB A-B 4 way 4 position float, spring center with float detent C-D 4 way 3 position spring center 2 Joystick & boot w/ dual spool lock, mounting feet to the left VALVES B Work ports on top, #6 SAE ORB 4 Direct acting adjustable 500-1500 PSI set at 1000 PSI 3 Joystick & boot without spool lock, mounting feet down/to rear 4 Joystick & boot without spool lock, mounting feet to the left 6 Pilot relief 500-3000 PSI (set at 2000 PSI) Note: Not for use with closed center sytems 8 No joystick or handle (tang ends on spool only) *For other relief settings please specify (see example on the left) LVS PRESSURE DROP 110 SUS OIL AT 115°F $ P-PSI FLOW (GPM) BOOM FLOAT BOOM LOWER BOOM FLOAT N BOOM LOWER BUCKET ROLLBACK N BUCKET ROLLBACK BUCKET TIP BUCKET REGEN RAPID TIP BUCKET TIP BUCKET REGEN RAPID TIP BOOM RAISE BOOM RAISE JOYSTICK HANDLE OPERATION LOOKING AT HANDLE KNOB REF HANDLE OPTION 1 CATV 51-03-16-03 JOYSTICK HANDLE OPERATION LOOKING AT HANDLE KNOB REF HANDLE OPTION 2 INLET TO OUTLET INLET TO WORK WORK PORTS TO OUTLET 4 6 22 4 6 18 44 19 10 64 100 60 PART NUMBER DESCRIPTION 660180170 671400252 660180154 6($/.,7 SPRING CENTER FLOAT KIT 635,1*&(17(55(*(1.,7 ROD END 52'(1':678' 6/,',1*6322/678' SPOOL LOCK HARDWARE 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 20 & 21 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V51 LVS SERIES LOADER VALVE DIMENSIONAL DATA #8 SAE ORB TOP POWER BEYOND PORT OPTION A (CONVERTIBLE TO STANDARD OPEN CENTER) #8 SAE ORB REAR OUTLET PORT 1.94 #8 SAE ORB REAR POWER BEYOND PORT OPTION B .75 2.54 1.16 2.81 5.25 5/16-18UNC-2B (3) 2.94 .27 3.17 C (5.53 REF) B 1.75 4.84 1.75 A 1.50 .20 D 1.00.05 1.31 1.44 (.66 REF) .87 2.08 WORK PORT OPTION A REAR PORT LOCATION (.34 REF) #8 SAE ORB REAR INLET PORT 1.22 2.75 (1.80 REF) (2.61 REF) (.82 REF) (7.5 REF) REMOTE CABLE CONTROL +HDY\GXW\UHPRWHFDEOHFRQWUROVDUHDYDLODEOHIRUPRVW3ULQFHGLUHFWLRQDOFRQWUROYDOYHV7KHFRPSDFWFRQWUROOHU ERGLHVDUHRIGLHFDVWPHWDOFRQVWUXFWLRQDQGDUHDYDLODEOHLQHLWKHUGXDOD[LVRUVLQJOHD[LVFRQÀJXUDWLRQV'XDO D[LVMR\VWLFNVDUHFRQVWUXFWHGZLWKVWHHOVZLYHOVDQGDQWLZHDUEXVKLQJV7KHKLJKVWUHQJWKÁH[LEOHFRQWUROFDEOHV DUHMDFNHWHGDQGKDYHTXLFNDWWDFKFRQQHFWLRQV 3ULQFH3DUW1R REMOTE CONTROLLERS 'XDO$[LV-R\VWLFNZLWKORFN 6LQJOH$[LV CONTROL CABLES LQFKHVORQJ0 LQFKHVORQJ0 LQFKHVORQJ0 LQFKHVORQJ0 LQFKHVORQJ0 VALVE CONNECTION KITS 5'VHULHVNLW /96/95RU/97NLWORDGHUYDOYHV 69VWDFNYDOYHRU5'NLW 6HULHVVWDFNYDOYHNLW 6,1*/(6322/&21752/ +DQGOHFDQEH DWWDFKHGYHUWLFDODV VKRZQRUKRUL]RQWDO 15.55 1.88 2.53 .32 dia.(4) 2.37 1.31 1RWH2QHFRQWUROFDEOHDQGRQHFRQQHFWLRQNLWLVUHTXLUHGIRU HDFKVSRROFRQWUROOHG2UGHUWKHUHPRWHFRQWUROOHUWKHFRQWURO FDEOHVDQGWKHFRQQHFWLRQNLWVDVQHFHVVDU\WRFRPSOHWHWKH UHPRWHFDEOHFRQWURODVVHPEO\ LOCK .25 dia.(2) 1.85 '8$/$;,6&21752//(5 10.00 1.57 .91 1.98 .25 dia.(2) 2.77 1.38 8" MIN BEND RADIUS )LHOGFRQYHUWLEOHRURUGHURSWLRQOHVVKDQGOHDVVHPEO\ C A )LHOGFRQYHUWLEOHIURPVWDQGDUGKDQGOHRURUGHURSWLRQ FOHYLVVSRROHQGRQO\ D 2UGHUORDGHUYDOYHKDQGOHRSWLRQWDQJHQGRQO\ B VALVES REMOTE CABLE CONTROLS FOR PRINCE VALVES )LHOGFRQYHUWLEOHRURUGHURSWLRQOHVVFRPSOHWHKDQGOH 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 21 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 52-07-13-02 MODEL LVT TWO SPOOL MONO-BLOCK LOADER VALVE LVT SPECIFICATIONS 3$5$//(/&,5&8,7 0$;,08023(5$7,1*35(6685( ................................ 36, 0$;,0807$1.35(6685( .............................................. 36, 0$;,08023(5$7,1*7(03(5$785( ............................. ) 5(&200(1'('6<67(0),/75$7,21 ...........,62 )/2:5$7,1* ......................................................................*30 :(,*+7 ............................................................................../%6 STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRIKLJK WHQVLOHVWUHQJWKJUD\FDVWLURQ /RDGFKHFNRQHDFKVSRRO +DUGFKURPHSODWHGVSRRO $GMXVWDEOHFDUWULGJHUHOLHI 2SHQFHQWHUDQGSRZHUEH\RQGDYDLODEOH 3RVLWLRQ)ORDW6SRROIRUORDGHUERRP 3RVLWLRQ5HJHQ6SRROIRUORDGHUEXFNHW 81&02817,1*+2/(621%27+723$1'%277202)9$/9( 127(1(875$/326,7,216322//2&.$9$,/$%/( MODEL NUMBER PORT SIZE SPOOL & ACTION RELIEF VALVE IN/OUT PORT POWER BEYOND HANDLE LVT Top Ported Two Spool Loader Valve 1 #8 SAE In & Out #6 SAE work ports GR Standard: A1-B1 4 Way 4 Position Float, Spring Center with Float Detent A2-B2 4 Way 4 Position Regen, Spring Center with Soft Stop RG A1-B1 4 Way 4 Position Regen, Spring Center with Soft Stop A2-B2 4 Way 4 Position Float, Spring Center with Float Detent GB A1-B1 4 Way 4 Position Float, Spring Center with Float Detent A2-B2 4 Way 3 Position Spring Centered BG A1-B1 4 Way 3 Position Spring Centered A2-B2 4 Way 4 Position Float, Spring Center with Float Detent BB A1-B1 4 Way 3 Position Spring Centered A2-B2 4 Way 3 Position Spring Centered 1 No Relief 4 Direct Acting Adjustable 500-1500 PSI Set at 1000 PSI 5 Standard: Direct Acting Adjustable 1500-3000 PSI Set at 2000 PSI 6 Pilot Operated Adjustable 500-3000 PSI Set at 2000 PSI A Standard: Top In, Out and Power Beyond B Standard: Open Center (Power Beyond Port Plugged) 1 Standard Handles 2 Clevis Spool End Only 3 Joystick for ports on bottom (Use with GR, GB, BG or BB) 4 Joystick for ports on left (Use with GR, GB or BB) 5 Joystick for ports on top (Use with RG, GB, BG or BB) 6 Joystick for ports on right (Use with RG, BG or BB) 7 Universal joystick contains parts and instructions for all mountings 8 Tang Spool End Only *LVT1GR5AB7-25 THE LAST TWO DIGITS ARE THE RELIEF SETTING IN HUNDREDS. EX: 25=2500 PSI @ 10 GPM. ALL RELIEFS ARE SET AT 10 GPM. B Side Inlet, Top Out & Power Beyond C #8 SAE Power Beyond D ** Closed Center (Often Used With No Relief. Review Application.) Note: Valve can be converted in the field. *For other relief settings please specify (see example on the left) 3/($6(127(WKDWWKLVFORVHGFHQWHURSWLRQGRHVQRWSURYLGHIRUWKHGUDLQRIIRIVWDQGE\VSRROOHDNDJH7KLVFDQDOORZDYHU\VPDOODPRXQWRI RLOWRHQWHUWKHZRUNSRUWVZKHQLQQHXWUDO&ORVHGFHQWHURSWLRQLVRIWHQXVHGZLWKQRUHOLHI5HYLHZDSSOLFDWLRQ STANDARD VALVES AVAILABLE: LVT PRESSURE DROP $OOVWDQGDUGYDOYHVKDYHDORDGFKHFNDFRPSOHWH KDQGOHDVVHPEO\DQGDQDGMXVWDEOHUHOLHI 6322/7<3( 9$/9(3$57 180%(5 4 WAY 4 POSITION FLOAT SPOOL LVT1BB5AB1 4 WAY 3 POSITION SPOOL 4 WAY 4 POSITION REGEN SPOOL LVT1GB5AB1 X X LVT1GB5AB3 X X LVT1GR5AB3 X X LVT1RG5AB5 X X LVT1BG5AB5 X CATV 53-07-13-02 $ P-PSI 6322/$&7,21 X X 110 SUS OIL AT 115°F A1-B1 SPOOL A2-B2 SPOOL 635,1* &(17(5 )/2$7 '(7(17 )/2$7 '(7(17 )/2$7 '(7(17 5(*(1 326,7,21 635,1* &(17(5 635,1* &(17(5 635,1* &(17(5 635,1* &(17(5 5(*(1 326,7,21 )/2$7 '(7(17 )/2$7 '(7(17 FLOW (GPM) INLET TO OUTLET INLET TO WORK PORTS A OR B TO OUTLET 4 15 20 8 6 35 34 20 10 95 72 50 PART NUMBER DESCRIPTION 6($/.,7 635,1*&(17(5.,7 635,1*&(17(5)/2$7.,7 635,1*&(17(55(*(1.,7 &203/(7(+$1'/(.,7 +$1'/(.,7 &/(9,668%$66< 5(/,()3/8* 5(/,()&$57237,21 3,/275(/,()&$57237,21 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 20 & 21 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V53 VALVES LVT MODEL LVR TWO SPOOL MONO-BLOCK LOADER VALVE LVR SPECIFICATIONS 3$5$//(/&,5&8,7 0$;,08023(5$7,1*35(6685( ......................... 36, 0$;,0807$1.35(6685( ....................................... 36, 0$;,08023(5$7,1*7(03(5$785( ....................... ) 5(&200(1'('6<67(0),/75$7,21 ....,62 )/2:5$7,1* ...............................................................*30 :(,*+7 ....................................................................... /%6 STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRI KLJKWHQVLOHVWUHQJWKJUD\FDVWLURQ /RDGFKHFNRQHDFKVSRRO +DUGFKURPHSODWHGVSRRO $GMXVWDEOHFDUWULGJHUHOLHI 2SHQFHQWHUDQGSRZHUEH\RQGDYDLODEOH 3RVLWLRQ)ORDW6SRROIRUORDGHUERRP 3RVLWLRQ5HJHQ6SRROIRUORDGHUEXFNHW 81&02817,1*+2/(621%27+723$1'%277202)9$/9( 127(1(875$/326,7,216322//2&.$9$,/$%/( LVR A MODEL NUMBER PORT SIZE SPOOL & ACTION RELIEF VALVE LVR Rear Ported Two Spool Loader Valve 1 Standard: #10 SAE in/out #8 SAE work ports GR Standard: A-B 4 Way 4 Position Float, Spring Center with Float Detent C-D 4 Way 4 Position Regen, Spring Center with Soft Stop 1 No Relief 2 #8 SAE in/out #6 SAE work ports VALVES *LVR1GB5AB7-25 THE LAST TWO DIGITS ARE THE RELIEF SETTING IN HUNDREDS. EX: 25=2500 PSI @ 10 GPM ALL RELIEFS ARE SET AT 10 GPM. IN/OUT PORT POWER BEYOND A All Ports On End of Valve B Standard: Open Center (Power Beyond Port Plugged) 4 Direct Acting Adjustable 500-1500 PSI Set at 1000 PSI RG A-B 4 Way 4 Position Regen, Spring Center with Soft Stop C-D 4 Way 4 Position Float, Spring Center with Float Detent C #8 SAE Power Beyond D ** Closed Center 5 Standard: Direct Acting Adjustable 1500-3000 PSI Set at 2000 PSI GB A-B 4 Way 4 Position Float, Spring Center with Float Detent C-D 4 Way 3 Position Spring Centered Note: Valve can be converted in the field. 6 Pilot Operated Adjustable 500-3000 PSI Set at 2000 PSI BG A-B 4 Way 3 Position Spring Centered C-D 4 Way 4 Position Float, Spring Center with Float Detent BB A-B 4 Way 3 Position Spring Centered C-D 4 Way 3 Position Spring Centered (no float, no regen) *For other relief settings please specify (see example on the left) 110 SUS OIL AT 115°F $ P-PSI 3/($6(127(WKDWWKLVFORVHGFHQWHURSWLRQGRHVQRWSURYLGHIRUWKHGUDLQRIIRIVWDQGE\VSRRO OHDNDJH7KLVFDQDOORZDYHU\VPDOODPRXQWRIRLOWRHQWHUWKHZRUNSRUWVZKHQLQQHXWUDO&ORVHG FHQWHURSWLRQLVRIWHQXVHGZLWKQRUHOLHI5HYLHZDSSOLFDWLRQ STANDARD VALVES AVAILABLE: $OOVWDQGDUGYDOYHVKDYHDORDGFKHFNDFRPSOHWH KDQGOHDVVHPEO\DQGDQDGMXVWDEOHUHOLHI SPOOL ACTION SPOOL TYPE VALVE PART NUMBER 4 WAY 4 POSITION FLOAT C-D SPOOL /95*%$% ; /95%*$% ; ; V54 1 Standard Handles 2 Clevis Spool End Only 3 Joystick for power beyond on Right (Use with GR, GB, BG or BB) 4 Joystick for power beyond on Bottom (Use with RG, BG or BB) 5 Joystick for power beyond on Left (Use with RG, BG, GB or BB) 6 Joystick for power beyond on Top (Use with GR, GB or BB) 7 Universal joystick contains parts and instructions for all mounting options 8 Tang Spool End Only LVR PRESSURE DROP FLOW (GPM) 4 WAY 4 POSITION 4 WAY FLOAT 3 POSITION A-B A-B SPOOL SPOOL HANDLE 4 Way 3 POSITION C-D SPOOL ; A-B SPOOL )/2$7 '(7(17 635,1* &(17(5 C-D SPOOL 635,1* &(17(5 )/2$7 '(7(17 INLET TO OUTLET INLET TO A OR B A OR B TO OUTLET 4 4 14 4 8 21 31 15 14 64 72 46 PART NUMBER DESCRIPTION 6($/.,7 32:(5%(<21' 6($/.,7 635,1*&(17(5.,7 635,1*&(17(5 )/2$7.,7 635,1*&(17(5 5(*(1.,7 &203/(7(+$1'/(.,7 +$1'/(.,7 &/(9,668%$66< 5(/,()3/8* 5(/,()&$57237,21 3,/275(/,()&$57 237,21 23(1&(17(53/8* 32:(5%(<21'&$57 6$( 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 20 & 21 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 54-07-13-02 MODEL LVT/LVR MOUNTING DIMENSIONS AND OPERATIONS 13.95 9.32 3.64 1.06 4.13 .40 9.06 .38 B2 A2 1.44 4.70 .72 A1 1.81 B1 2.69 T P 1.31 PB 5/16-18UNC (6) POWER BEYOND 1.03 .63 2.06 3.47 INLET OUTLET SPOOL TRAVEL: .203 TO WORK .437 TO FLOAT AND REGEN 4.89 7.44 14.42 7.88 3.66 .44 2.53 POWER BEYOND C #10 OUTLET 1.44 1.55 3.19 B 4.58 6.34 #8 WORK PORTS .95 1.56 3.25 5/16-18UNC (6) VALVES .88 A 1.77 .11 1.57 #10 INLET HCI-PRINCE D 3.20 SPOOL TRAVEL: .203 TO WORK .396 TO REGEN .425 TO FLOAT 4 WAY 4 POSITION REGEN SPOOL OPERATION 7KLVVSRRORSWLRQDOORZVIRUWKHVHIRXUIXQFWLRQVRIWKHORDGHUEXFNHWF\OLQGHUV´1(875$/µF\OLQGHUSRUWVEORFNHGWRKROGEXFNHW LQSODFH´%8&.(752//%$&.µGLUHFWVRLOWRKRVHWRUHWUDFWEXFNHWF\OLQGHU´%8&.(77,3µGLUHFWVRLOWRKRVHWRH[WHQGWKH EXFNHWF\OLQGHUZLWKIXOOSUHVVXUH3OHDVH1RWHWKHUHLVDVRIWVWRSDWWKLVKDQGOHSRVLWLRQ´%8&.(75(*(1µFRPELQHVWKHRLOIURP WKHWUDFWRUSXPSZLWKWKHRLOUHWXUQLQJIURPKRVHDQGLWGLUHFWVLWWRKRVHWRWLSWKHEXFNHWIDVWHUUHIHUUHGWRDV5(*(1(5$7,21 RU´5(*(1µ,WLVQHFHVVDU\WRSXVKWKHKDQGOHSDVWWKHVRIWVWRSDWWKHQRUPDOEXFNHWWLSSRVLWLRQWRJHWWRWKHUHJHQSRVLWLRQ$OVR 3OHDVH1RWHWKDWWKHF\OLQGHUIRUFHZLOOEHUHGXFHGZKHQLQWKHUHJHQSRVLWLRQ 4 WAY 4 POSITION FLOAT SPOOL OPERATION 7KLVVSRRORSWLRQDOORZVIRUWKHVHIRXUIXQFWLRQVRIWKHORDGHUERRPF\OLQGHUV´1(875$/µF\OLQGHUSRUWVEORFNHGWRKROGERRPLQSODFH ´%2205$,6(µGLUHFWVRLOWRKRVHWRH[WHQGERRPF\OLQGHUV´%220/2:(5µGLUHFWVRLOWRKRVHWRUHWUDFWWKHERRPF\OLQGHUV ZLWKIXOOSUHVVXUH3OHDVH1RWHWKHUHLVDVRIWVWRSDWWKLVKDQGOHSRVLWLRQ´%220)/2$7µFRQQHFWVDOOERRPF\OLQGHUSRUWVWRWDQN DOORZLQJWKHERRPWRIDOOWRWKHJURXQG,WLVQHFHVVDU\WRSXVKWKHKDQGOHSDVWWKHVRIWVWRSDWWKHQRUPDOERRPGRZQSRVLWLRQ7KHUH LVDGHWHQWWKDWZLOOKROGKDQGOHLQWKHÁRDWSRVLWLRQ:KLOHLQWKHÁRDWSRVLWLRQWKHORDGHUERRPF\OLQGHUVZLOOPRYHXSDQGGRZQRU ´)/2$7µWRPDWFKWKHJURXQGOHYHODVWKHWUDFWRUPRYHVIRUZDUGRUEDFNZDUG Joystick Handle 1 ROLL BACK CATV 55-07-13-02 2 TIP 3 RAISE 4 LOWER 7KHMR\VWLFNKDQGOHZLOORSHUDWH ERWK VSRROV XVLQJ RQH OHYHU KDQGOH7KHWZRVSRROVFDQEH RSHUDWHG LQGHSHQGHQWO\ RU DW WKHVDPHWLPHGHSHQGLQJXSRQ KDQGOHPRYHPHQW%HFDXVHZH DOORZ IRU PD[LPXP PRXQWLQJ ÁH[LELOLW\ZHKDYHRSWLRQVIRU WKH /97 RSWLRQV IRU WKH /96 DQGRSWLRQVIRUWKH/957KH KDQGOH VKLIW SDWWHUQ IRU DOO LV VKRZQDWULJKW BOOM FLOAT BOOM LOWER N BUCKET ROLLBACK BUCKET TIP BUCKET REGEN RAPID TIP BOOM RAISE JOYSTICK HANDLE OPERATION LOOKING AT HANDLE KNOB 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V55 Directional Control Valves LOG SPLITTER CONTROL VALVE VALVES Model LS3000 SINGLE SPOOL MONO-BLOCK 20GPM Model RD2500 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 56-07-13-02 MODEL LS3000 DIMENSIONAL DATA 2Q/60RGHOVSUHVVXUHUHOHDVHGHWHQWLVLQWKHVSRRO RXWSRVLWLRQ 2Q/60RGHOVSUHVVXUHUHOHDVHGHWHQWLVLQWKHVSRRO LQSRVLWLRQ OUTLET PORT SPECIFICATIONS: 0D[GHVLJQDQGWHVWSUHVVXUH36, 0D[WDQNSRUWSUHVVXUH36, )ORZUDWLQJ*30PD[ 5HOLHIYDOYHVHWWLQJ36, 7KLVYDOYHKDVRQHSRVLWLRQSUHVVXUH UHOHDVHGHWHQWZLWKVSULQJFHQWHUWRQHXWUDO :HLJKWOEV 5HFRPPHQGHGÀOWUDWLRQ,62 0D[RSHUDWLRQWHPS) ,QH[SRVHGHQYLURQPHQWVGRQRWPRXQW ZLWKVSRROYHUWLFDODQGKDQGOHHQGGRZQ 4.62 2.51 .343 DIA. (3) A & B WORK PORTS 1.05 1.25 OUT .44 1.42 A B 3.25 8.25 INLET PORT 1.84 5.12 IN 2.93 1.13 7.80 4.12 12.31 PARTS LIST - LOG SPLITTER VALVES ITEM PART NUMBER DESCRIPTION +$1'/(.,7 5(/,().,7 635,1*&(17(5.,7 '(7(176/((9(3,62168%$66< '(7(17$'-867,1*&$575,'*( &203/(7(35(6685(5(/($6( '(7(17.,7 6($/.,7&217$,166($/6)25 6322/$1''(7(17 MODEL LSR-3060 RAPID EXTEND LOG SPLITTER VALVE STANDARD FEATURES +\GUDXOLFDOO\EDODQFHGKDUGFKURPHSODWHGVSRRO +DQGOHFDQEHLQVWDOOHGLQ´XSµRU´GRZQµSRVLWLRQ ([WHQGÁRZVRIXSWR*30ZLWKLQOHWÁRZVRI*30 5HOLHIYDOYHDGMXVWDEOHXSWR36, 7DQGHPFHQWHUVSRRO 0DQXDOVKLIWIURPKLJKVSHHGPRGHWRKLJKIRUFHPRGH 6SULQJFHQWHUSRVLWLRQVSRROZLWKVRIWVWRS 3UHVVXUHUHOHDVHGHWHQWRQUHWUDFW FUNCTION: 7KH3ULQFH/65ORJVSOLWWHUYDOYHIHDWXUHVDQH[ WUHPHO\ IDVW ´5DSLG ([WHQGµ KLJKVSHHGPRGH7KH/65 KDVEHHQVSHFLÀFDOO\GHVLJQHGWRUHGXFHV\VWHPFRVWVE\ DOORZLQJDVLQJOHVWDJHSXPSWREHXVHGLQV\VWHPVFXU UHQWO\XVLQJWZRVWDJHKLORZSXPSV:KHQH[WUDVSOLWWLQJ IRUFHLVUHTXLUHGWKH/65DOORZVWKHXVHUWRPDQXDOO\VKLIW IRUP KLJK VSHHGPRGH WR KLJK IRUFHPRGH$´VRIWVWRSµ GLIIHUHQWLDWHVEHWZHHQKLJKIRUFHDQGKLJKVSHHGPRGHV /DERUDWRU\WHVWLQJKDVQRWVKRZQDVLJQLÀFDQWGLIIHUHQFH LQZRUNLQJF\FOHWLPHVEHWZHHQVLQJOHVWDJHUDSLGH[WHQG V\VWHPV DQG WZR VWDJH V\VWHPV :RUNLQJ F\FOH LV WKH DYHUDJHWLPHEHWZHHQH[WHQGLQJWKHF\OLQGHUWRVSOLWWKH ÀUVWORJDQGH[WHQGLQJWRVSOLWWKHQH[WORJDIWHUWKHVSOLW ZRRGKDVEHHQUHPRYHGDQGDQHZORJKDVEHHQSODFHG RQWKHORJVSOLWWHU CATV 57-07-13-02 SPECIFICATIONS: 0D[GHVLJQDQGWHVWSUHVVXUH36, 0D[WDQNSRUWSUHVVXUH36, 1RPLQDOLQOHWÁRZUDWLQJJSP 6WDQGDUGUHOLHIYDOYHVHWWLQJ²SVL 7KLVYDOYHKDVDSUHVVXUHUHOHDVHGHWHQWIURPVSRROLQ ZVSULQJFHQWHUWRQHXWUDO 7KHYDOYHKDVDSRVLWLRQVSRROZLWKQRUPDOH[WHQGDQG UHWUDFWSRVLWLRQVDQGDWKUDSLGH[WHQGSRVLWLRQ 0D[RSHUDWLQJWHPSHUDWXUH) ,QH[SRVHGHQYLURQPHQWVGRQRWPRXQWZLWKVSRROLQWKH YHUWLFDOSRVLWLRQ 'LPHQVLRQDOO\VLPLODUWRWKH/6YDOYH ,QFHQWHUSRVLWLRQ%SRUWFRQQHFWHGWRWDQN A-Rod end of Cylinder B-Base end of Cylinder P 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 22 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES STANDARD FEATURES +\GUDXOLFDOO\EDODQFHGKDUGFKURPHSODWHGVSRRO +DQGOHFDQEHLQVWDOOHGLQ´XSµRU´GRZQµSRVLWLRQ 'HWHQWUHOHDVHSUHVVXUHDGMXVWDEOHIURPWR36, )RUXVHZLWKV\VWHPÁRZVXSWR*30 5HOLHIYDOYHDGMXVWDEOHXSWR36, 7DQGHPFHQWHUVSRROLQQHXWUDOSRVLWLRQERWKZRUNSRUWV EORFNHGSXPSXQORDGHGWRWDQN ,GHDOIRUORJVSOLWWHUDSSOLFDWLRQV$YDLODEOHZLWKµ 137)ZRUNSRUWVIRUKLJKHUÁRZDSSOLFDWLRQV 9.19 MODEL RD2500 DIMENSIONAL DATA STANDARD FEATURES (FRQRPLFDOPRQREORFNFRQVWUXFWLRQRIKLJKWHQVLOH VWUHQJWKJUD\FDVWLURQ /RDGFKHFN +DUGFKURPHSODWHGVSRRO $GMXVWDEOHEDOOVSULQJUHOLHI36,WR36, 2SHQFHQWHUWRFORVHGFHQWHUFRQYHUVLRQDYDLODEOHRQ VRPHPRGHOV )RUXVHZLWKV\VWHPÁRZVWR*30 )RUXVHZLWKV\VWHPSUHVVXUHVWR36, SPECIFICATIONS: 0D[GHVLJQDQGWHVWSUHVVXUH36, 0D[WDQNSRUWSUHVVXUH36, )ORZUDWLQJ*30PD[ 5HOLHIYDOYHVHWWLQJ36, :HLJKW,EV 5HFRPPHQGHGÀOWUDWLRQ,62 0D[RSHUDWLRQWHPS) ,QH[SRVHGHQYLURQPHQWVGRQRWPRXQW ZLWKVSRROYHUWLFDODQGKDQGOHHQGGRZQ 4.88 OUTLET PORT 3.75 1.18 .90 .46 8.25 OUT 3.00 2.13 B A 1.50 4.25 3.00 3.06 IN 2.13 1.06 3.09 7.75 12.00 .343 DIA. (3) 9.06 A & B WORK PORTS INLET PORT A B 2 3 ( 1 7 2 & / 2 6 ( ' & ( 1 7 ( 5 &219(56,21 7KLV IHDWXUH DOORZV DQRWKHUZLVHRSHQFHQWHUYDOYHWREH FRQYHUWHGWRFORVHGFHQWHURSHUDWLRQ $V VKRZQ D 137) SLSH SOXJ LV LQVWDOOHGLQWKHERWWRPRIWKHRXWOHWSRUW WREORFNRSHQFHQWHUSDVVDJH$SLSH WKUHDG VHDODQW VKRXOG EH XVHG 7KLV IHDWXUH LV VWDQGDUG RQ DOO YDOYHV ZLWK 137) LQOHW DQG RXWOHW SRUWV 7KH SLSHSOXJLVLQFOXGHGZLWKWKHVHPRGHOV 'LVFDUG WKH SLSH SOXJ LI WKH YDOYH LV XVHG RQ DQ RSHQ FHQWHU DSSOLFDWLRQ 3/($6(127(WKDWWKLVFORVHGFHQWHU RSWLRQ GRHV QRW SURYLGH IRU WKH GUDLQ RIIRIVWDQGE\VSRROOHDNDJH7KLVFDQ DOORZDYHU\VPDOODPRXQWRIRLOWRHQWHU WKHZRUNSRUWVZKHQLQQHXWUDO OUTLET PORT OUT VALVES RD-2555-T4-ESA 1 PARTS BREAKDOWN 1 4 3 2 3/8 NPTF PIPE PLUG PART NO. 200018002 NOTE:7KH6SRROLV VHOHFWÀWWRWKHYDOYH ERG\DWWKHIDFWRU\ DQGWKHUHIRUHERG\ DQGVSRRODUHQRW DYDLODEOHDVUHSDLU SDUWV 5 12167$1'$5'5(/,()6(77,1*6 5'7(6$ 7+(/$677:2',*,76$5(7+(5(/,()6(77,1* ,1+81'5('6([ 36,#*30$// 5(/,()6$5(6(7$7*30 9 ITEM PART NUMBER 6 3 POSITION DETENT DESCRIPTION +$1'/(.,7 5(/,().,7 6($/.,7 635,1*&(17(5.,7 /2$'&+(&..,7 326,7,21'(7(17.,7 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 22 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 58-07-13-02 LS-3000, RD-2500 PRESSURE DROP, RELIEF CURVE AND STANDARD MODELS PRESSURE DROP 110 SUS OIL AT 115° LS-3000/RD-2500 RELIEF VALVE CURVES AT VARIOUS SET POINTS 110 SUS OIL AT 115°F $ P-PSI RD-2500 INLET TO OUTLET LS-3000 INLET TO A OR B INLET TO A OR B TO OUTLET OUTLET INLET TO A OR B A OR B TO OUTLET 5 5 20 8 3 5 4 10 9 39 15 5 11 13 15 19 60 32 7 23 24 20 31 90 54 11 40 42 3000 PRESSURE (PSI) FLOW (GPM) 2500 2000 1500 1000 STANDARD VALVES AVAILABLE All standard valves have a load check (except LS3000 models), a complete lever handle assembly, and an adjustable ball-spring relief, see below for settings. For other relief settings, please specify. RD-2555-T4-ESA1 X X RD-2575-T4-ESA1 X X RD-2575-T4-EDA1 X X X RD-2575-M4-ESA1 RD-2508-T4-ESA1 X X RD-2575-M4-EDA1 LS-3000-1 (detent spool out) LS-3000-9 (detent spool out) LS-3000-2 (detent spool out) LS-3060-1 (detent spool in) LS-3060-9 (detent spool in) LS-3040-1 X X X X X X X X X X X X X X X LSR-3060-3 (detent spool in) LSR-3060-8 (detent spool in) X 4 WAY 4 POSITION W/ MANUAL RAPID EXTEND 4 WAY 4 POSITION W/ MANUAL RAPID EXTEND 4 WAY SPOOL WORK PORT SIZE 8 12 16 FLOW (GPM) X X 20 RELIEF CONVERTIBLE SETTING FROM OPEN To Specify CENTER Other Settings See Previous TO CLOSED CENTER Page 1/2 NPTF 1/2 NPTF 1500 PSI @ 12 GPM 1500 PSI @ 3/4 NPTF 1/2 NPTF 12 GPM 3/4 NPTF 1/2 NPTF 1500 PSI @ 12 GPM 1500 PSI @ 3/4 NPTF 1/2 NPTF 12 GPM 1500 PSI @ 3/4 NPTF 1/2 NPTF 12 GPM 1500 PSI @ #10 SAE #8 SAE 12 GPM 3/4 NPTF 1/2 NPTF 1500 PSI @ 12 GPM 2250 PSI @ 3/4 NPTF 1/2 NPTF 3 GPM 3/4 BSPP 3/4 BSPP 2250 PSI @ 3 GPM 2250 PSI @ 3/4 NPTF 3/4 NPTF 3 GPM 2250 PSI @ 3/4 NPTF 1/2 NPTF 3 GPM 3/4 BSPP 3/4 BSPP 2250 PSI @ 3 GPM 2250 PSI @ 3/4 NPTF 1/2 NPTF 12 GPM 2250 PSI @ 1/2 NPTF 3/4 NPTF 3 GPM 2250 PSI @ 1/2 BSPP 3/4 BSPP 3 GPM X RD-2575-T3-ESA1 4 SPOOL ACTION PRESSURE RELEASE SPRING 4 WAY IN/OUT 3 WAY 4 WAY DETENT CENTER 3 POSITION 3 POSITION PORT SIZE DETENT 3 POSITION 3 POSITION SPRING TO MOTOR CENTER TO NEUTRAL NEUTRAL VALVE PART NUMBER NO YES YES YES YES YES YES NO NO NO NO NO NO NO NO 3 WAY SPOOL 4 WAY MOTOR SPOOL LOAD CHECK B A This spool option is used to control a single acting cylinder or a uni-directional motor. In neutral the work port is blocked and oil goes through the open center passage to the outlet. The “B” work port is plugged for this option. A This spool option is used to control a reversing motor or a double acting cylinder. In neutral the work ports are connected to tank and oil goes through the open center passage to the outlet. This allows a motor to free-wheel or a F\OLQGHUWRÁRDWLQWKHQHXWUDOSRVLWLRQ B A The load check feature is standard on all RD-2500 valve models. The load check will prevent the fall of a cylinder as the spool is shifted. It does this by preventing WKHEDFNÁRZRIRLOIURPZRUNSRUW to inlet. The pump must build up enough pressure to overcome the pressure on the work port and lift the load check poppet. The load check has nothing to do with holding a cylinder when the spool is in neutral. P-T P-T This spool option is used to control a double acting cylinder. In neutral both of the work ports are blocked and oil goes through the open center passage to the outlet. This is the most popular spool option. CATV 59-01-16-03 0 VALVES SPOOL TYPE 500 P-T 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 22 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V59 PRIORITY FLOW REGULATOR PRIMARY 7/8-14UNF-2A SECONDARY IN .747 DIA. .745 DESCRIPTION: 7KLV YDOYH LV D VFUHZLQ FDUWULGJH VW\OH SUHVVXUH FRPSHQVDWHG À[HGÁRZ SULRULW\ ÁRZ UHJXODWRU 7KH YDOYH GHOLYHUV D FRQVWDQW IORZ WR WKH SULRULW\ SRUW UHJDUGOHVV RI SUHVVXUH RQ WKH VHFRQGDU\ RU SULPDU\ FLUFXLW$OOSRUWVFDQEHIXOO\SUHVVXUL]HG .685 DIA. .683 2.062 - FR10-3P - - BASIC CARTRIDGE MODEL NUMBER .766 PRIORITY FLOW SETTING PORTS B O BUNA-N CARTRIDGE ONLY V 3P VITON 3/8 NPTF 6S #6 SAE 8S #8 SAE SPECIFICATIONS 0$;,08035(6685( .............................. 36, 0$;,080,1/(7)/2:...............................*30 0$;,080&21752/)/2: .........................*30 )/2:$&&85$&<WR*30 .................... 0$;,0807(03(5$785( ............................ ) 5(&200(1'('),/75$7,21 ...,62 7+(&$575,'*(,6$//67((/&216758&7,21 7+(9$/9(%2',(6$5(+,*+675(1*7+ $/80,180 ,167$//$7,2172548()7/%6 VALVES 1.5 GPM PRIORITY FLOW 2.0 GPM PRIORITY FLOW 2.5 GPM PRIORITY FLOW 3.0 GPM PRIORITY FLOW 3.5 GPM PRIORITY FLOW 4.0 GPM PRIORITY FLOW 4.5 GPM PRIORITY FLOW 5.0 GPM PRIORITY FLOW IN REG. FLOW SEC. FOR PRIORITY FLOW SETTINGS OR PORT SIZES NOT LISTED, CONTACT YOUR SALES REPRESENTATIVE. PRIORITY IN PMC CAVITY PMC10-3L .281 .75 .810 DIA. .814 .750 .752 DIA. .688 DIA. .690 1.25 #10 SAE PORT TAP 7/8-14UNF-2B .312 DIA. MAX 2.50 2.00 .920 .25 30° .63 .719 1.469 1.810 1.50 2.88 2.125 3.25 30° SECONDARY 30° .438 DIA. MAX .75 1.50 .563 DIA. 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 24 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 60-07-13-02 PRESSURE COMPENSATED ADJUSTABLE FLOW CONTROL VALVES MODEL RD-100 7233257)/2:&21752/ 7KH35,1&(YDOYHPRGHOV5'DQG5'DUHSUHVVXUHFRPSHQ VDWHGDGMXVWDEOHÁRZFRQWUROYDOYHV%\URWDWLQJWKHKDQGOHWKHÁRZRXW WKH´&)µRUFRQWUROOHGÁRZSRUWFDQEHYDULHGIURPDSSUR[LPDWHO\WR WKHPD[LPXPFRQWUROOHGÁRZVKRZQLQWKHFKDUWEHORZ$Q\UHPDLQLQJ ÁRZLVE\SDVVHGWRWKH´()µRUH[FHVVÁRZSRUW7KLVÁRZFDQEHXVHGWR SRZHUDQRWKHUFLUFXLWRUFDQEHUHWXUQHGWRWDQN2QFHWKHFRQWUROOHGÁRZ LVVHWLWZLOOUHPDLQQHDUO\FRQVWDQWZLWKYDULDWLRQVLQSUHVVXUHRQHLWKHU WKHFRQWUROOHGRUH[FHVVÁRZSRUWV 3OHDVHQRWH,IGXULQJRSHUDWLRQWKHFRQWUROOHGÁRZSRUWLVEORFNHGWKH YDOYHZLOOFRPSHQVDWHLQVXFKDZD\DVWRVKXWRIIÁRZWRWKHH[FHVVSRUW 7KHVHYDOYHVFDQDOVREHXVHGDVDUHVWULFWLYHÁRZFRQWUROE\SOXJJLQJ WKHH[FHVVÁRZSRUW MODEL RD-1900 6,'(3257)/2:&21752/ 7KH35,1&(YDOYHPRGHOV5'56DQG5'56KDYHDEXLOWLQ DGMXVWDEOHSUHVVXUHUHOLHI)RUWKHVHPRGHOVWKHH[FHVVÁRZSRUWmust EHFRQQHFWHGWRWDQN ,WVKRXOGEHQRWHGWKDWZKHQHYHUWKHVHRUDQ\YDOYHLVXVHGWRE\SDVV RUUHVWULFWÁRZKHDWZLOOEHJHQHUDWHG6WHSVPD\EHUHTXLUHGWRNHHSRLO WHPSHUDWXUHIURPEHFRPLQJWRRKLJK STANDARD MODELS AVAILABLE MODEL NUMBER PORT SIZES CONTROLLED FLOW RANGE RD-137-8 RD-1937-8 137) *30 RD-150-8 RD-1950-8 137) *30 RD-150-16 RD-1950-16 137) *30 RD-175-16 RD-1975-16 137) *30 RD-175-30 RD-1975-30 137) *30 RD-108-8 RD-1908-8 6$( *30 RD-112-30 RD-1912-30 6$( *30 RDRS-150-16 RDRS-1950-16 137) *30 RDRS-175-30 RDRS-1975-30 137) *30 FIELD REPAIR KITS: +DQGOHKDUGZDUH 6HDO.LW )RU2WKHU5HOLHI6HWWLQJV3OHDVH6SHFLI\ 5'56 5HOLHI3UHVVXUHLQ +XQGUHGV([DPSOH 36, 5'56 5HOLHI3UHVVXUHLQ +XQGUHGV([DPSOH 36, These models have built in relief set at 1500 psi @ 10 GPM. 6SHFLDOFRPELQDWLRQVRISRUWVL]HDQGFRQWUROOHGÁRZUDQJHDUHDYDLODEOHLQ2(0TXDQWLWLHV 3OHDVHFRQVXOW\RXUVDOHVUHSUHVHQWDWLYH SYMBOL CF EF CF EF IN RD-100 & RD-1900 CATV 61-07-13-02 IN RDRS-100 & RDRS-1900 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 22 & 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES VALVE SPECIFICATIONS: &DSDFLW\ JSPPD[LQOHWÁRZ 3UHVVXUH SVLPD[ :HLJKW 5'OEV 5'OEV MODEL RD-100 AND RD-1900 PARTS BREAKDOWN AND DIMENSIONS MODEL RD-100 CONTROL FLOW PORT 1.75 .88 .38 670400005 EXCESS FLOW PORT 670300008 3.88 2.05 .88 .265 DIA (2) 190100018 1.00 240000912 PART NUMBER WILL BE STAMPED IN THIS LOCATION 670400004 4.13 RDRS MODEL RELIEF VALVE PARTS 230005093 2.38 671600002 670400006 671800010 671500004 671800002 ROTARY SPOOL 220000762 2.88 3.34 .13 1.18 5.00 240000116 240016072 MODEL RD-1900 670801001 2.31 1.75 .88 INLET MAIN SPOOL 670300008 CONTROL FLOW PORT .38 670400005 670300011 230009014 EXCESS FLOW PORT 3.88 ADJUSMENT SCREW 671900001 190100018 1.69 4.81 .265 DIA (2) .88 PART NUMBER WILL BE STAMPED IN THIS LOCATION 670400004 230005093 240000912 2.16 671600002 VALVES 670400006 ROTARY SPOOL .13 2.88 3.34 240000116 1.18 2.31 220000762 670801001 5.00 240016072 INLET MAIN SPOOL APPLICATIONS: $V LOOXVWUDWHG LQ WKH FLUFXLW EHORZ WKH 5'5' DGMXVWDEOHÁRZFRQWUROYDOYHVFDQEHXVHGWRFRQWUROWKH VSHHGRIDK\GUDXOLFPRWRU,QWKLVFLUFXLWRLOIURPDVRXUFHLV GLUHFWHGLQWRWKHLQOHWRIWKHYDOYH%\PRYLQJWKHKDQGOHWKH ÁRZFDQEHYDULHGIURPDSSUR[LPDWHO\]HURZKHQKDQGOHLV YHUWLFDOWRPD[LPXPZKHQWKHKDQGOHLVKRUL]RQWDO2LOQRW JRLQJWRWKHFRQWUROOHGÁRZSRUWLVE\SDVVHGWRWKHH[FHVV ÁRZ SRUW ZKHUH LW FDQ EH XVHG WR VXSSO\ DQRWKHU FLUFXLW BYPASS FLOW CIRCUIT RU UHWXUQHG WR WDQN ,QVWHDG RI WKH FRQWURO ÁRZ GLUHFWO\ VXSSO\LQJDPRWRULWFDQEHXVHGDVDDGMXVWDEOHSULRULW\ GLYLGHUDQGSURYLGHDGMXVWDEOHSULRULW\ÁRZWRDGLUHFWLRQDO FRQWUROYDOYHEDQN$OVRDVLOOXVWUDWHGWKH5'5' FDQEHXVHGDVDUHVWULFWLYHW\SHÁRZFRQWURO,QWKLVFLUFXLW WKHH[FHVVÁRZSRUWLVEORFNHG7KLVZRXOGQRUPDOO\EH XVHGZLWKDSUHVVXUHFRPSHQVDWHGSXPSRULQDFORVHG FHQWHUV\VWHP RESTRICTIVE FLOW CIRCUIT MOTOR MOTOR TO TANK OR SECONDARY CIRCUIT (EXCESS FLOW PORT) (CONTROLLED FLOW PORT) (CONTROLLED FLOW PORT) (EXCESS FLOW PORT PLUGGED) RD-100 (INLET) 9 RD-100 (INLET) 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 62-07-13-02 CONSTANT VOLUME PRIORITY DIVIDERS MODEL RD-400 ),;(')/2:35,25,7< ',9,'(5 7KH35,1&(PRGHO5'LVDFRQVWDQWYROXPHSULRULW\GLYLGHU,WFDQ EHXVHGLQDSSOLFDWLRQVZKHUHWZRFLUFXLWVDUHWREHVXSSOLHGE\DVLQJOH SXPSVXFKDVSRZHUVWHHULQJV\VWHPV,QRSHUDWLRQWKHÁRZRIRLOVXSSOLHG WRWKHLQOHWLVGLYLGHGLQWRWZRÁRZVWKHSULRULW\ÁRZDQGWKHH[FHVVÁRZ 7KHSULRULW\ÁRZZLOOUHPDLQQHDUO\FRQVWDQWZLWKYDULDWLRQVLQSUHVVXUHRQ HLWKHUWKHSULRULW\RUH[FHVVÁRZSRUWDQGZLOODOVRUHPDLQQHDUO\FRQVWDQW ZLWKYDULDWLRQVLQWKHLQOHWÁRZ 7KHSULRULW\ÁRZ*30LVGHWHUPLQHGE\DÀ[HGRULÀFHLQVLGHWKHPDLQ VSRRO7KHGHVLUHGSULRULW\*30PXVWEHVSHFLÀHGZLWKPRGHOQXPEHU VHHEHORZ7KH35,1&(PRGHO5'5SURYLGHVWKHVDPHIXQFWLRQDV GHVFULEHGDERYHZLWKWKHDGGLWLRQRIDEXLOWLQSUHVVXUHUHOLHIIRUWKHSULRULW\ SRUWRQO\7KLVUHOLHILVLQWHUQDOO\DGMXVWDEOHDQGUHTXLUHVDVHSDUDWHOLQH WRWDQN7KHUHOLHILVIDFWRU\VHWDW36, MODEL RD-400 R ),;(')/2:35,25,7< ',9,'(5:,7+35,25,7< 35(6685(5(/,() :HLJKW 5' ,EV 5'5,EV STANDARD MODELS AVAILABLE 32576,=( 9$/9( 02'(/180%(5 RD-400- ___ RD-405- ___ RD-412- ___ RD-450- ___ RD-455- ___ RD-477- ___ RD-400RRD-405RRD-412RRD-450RRD-455RRD-477R- ,1/(7$1' (;&(663257 __ __ __ __ __ __ 137) 137) 6$( 137) 137) 137) 35,25,7< 3257 137) 137) 6$( 137) 137) 137) 7RFRPSOHWHWKHPRGHOQXPEHUÀOOLQWKHEODQNZLWKWKH GHVLUHGSULRULW\*30IURPWKHOLVWDWULJKW EX:5'3IRU3 GPMSULRULW\ÁRZ5'56IRU6 GPM SULRULW\ÁRZ MODEL RD-500 $'-867$%/()/2: 35,25,7<',9,'(5 PRIORITY GPM 3 4 5 VALVES VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ 7KH35,1&(PRGHO5'LVDQDGMXVWDEOHFRQVWDQWYROXPHSULRULW\ GLYLGHU7KLV YDOYH SURYLGHV WKH VDPH IXQFWLRQ DV WKH 35,1&( PRGHO 5'H[FHSWWKHSULRULW\ÁRZLVDGMXVWDEOHIURP*30WR*30 7KHSULRULW\ÁRZLVVHWXVLQJWKHDGMXVWLQJVFUHZDQGLVWKHQORFNHGLQ SODFHWRPDLQWDLQVHWWLQJ7KLVDOORZVVHWWLQJWREHÀQHWXQHGLQWKHÀHOG WRWKHH[DFWÁRZQHHGHG VALVE SPECIFICATIONS &DSDFLW\ JSPPD[LQOHWÁRZ 3UHVVXUH SVLPD[ :HLJKW ,EV STANDARD MODELS AVAILABLE CATV 63-07-13-02 VALVE MODEL NUMBER PORT SIZE RD-537 RD-550 RD-575 137) 137) 137) 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 MODEL RD-400, RD-400R AND RD-500 PARTS BREAKDOWN AND DIMENSIONS RD-400 4.63 3.88 PRIORITY FLOW 2.05 .38 1.75 .88 EXCESS FLOW SYMBOL .91 .265 DIA (2) 1.00 CF EF 240000912 671600002 4.13 IN RD-400 VALVE BODY 670300008 SPOOL ORIFICE PLUG INLET 2.31 SEAL KIT NO. 660504001 RD-400R 1.75 4.63 3.88 PRIORITY FLOW 2.05 .38 .88 SYMBOL EXCESS FLOW .91 CF EF .265 DIA (2) 1.00 240000912 671600002 VALVES ADJUSTMENT SCREW 4.13 RD-400R VALVE BODY 3/8 NPTF TANK PORT ALL MODELS INLET 2.31 660204001 RELIEF CARTRIDGE ORIFICE PLUG SPOOL 670300008 RD-500 4.63 3.88 PRIORITY FLOW 2.05 .38 1.75 IN T .88 SEAL KIT NO. 660504002 EXCESS FLOW SYMBOL .91 .265 DIA (2) 1.00 CF EF 240000912 671600002 4.13 IN ADJUSTMENT SCREW RD-500 VALVE BODY INLET 2.31 660305001 PLUG SPOOL SEAL KIT NO. 660505001 670300008 NOTE: VSRROVDUHQRWDYDLODEOHVHSDUDWHO\ 9 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 64-07-13-02 PRESSURE COMPENSATED PROPORTIONAL FLOW DIVIDERS MODEL RD-200 3523257,21$/',9,'(5 7KH 35,1&( PRGHO 5' YDOYH LV D SUHVVXUH FRPSHQVDWHG SURSRUWLRQDO ÁRZ GLYLGHU7KHVWDQGDUGPRGHOVRIWKLVYDOYHZLOOWDNHRQHLQOHWÁRZDQGVSOLWLWLQWRWZR QHDUO\HTXDORXWOHWÁRZV7KHYDOYHLVDOVRDYDLODEOHZLWKVSHFLDOUDWLRVSRROVZKLFK ZLOOVSOLWWKHÁRZLQWRWZRÁRZVSURSRUWLRQDOWRWKHUDWLRVSHFLÀHG%HFDXVHWKHYDOYH LVSUHVVXUHFRPSHQVDWHGWKHYDOYHZLOOPDLQWDLQWKHGLYLGHUUDWLRZLWKTXLWHGLIIHUHQW ORDGVRQWKHRXWOHWSRUWVDVORQJDVWKHLQOHWÁRZLVZLWKLQWKHUDQJHJLYHQLQWKHFKDUW EHORZFlow through the RD-200 cannot be reversed. 7KH35,1&(PRGHO5'SURYLGHVWKHVDPHIXQFWLRQDVWKH5'ZLWKWKHDGGHG IHDWXUHRIIUHHUHYHUVHFKHFNV7KLVDOORZVWKHUHYHUVHÁRZRIRLOIURPWKHRXWOHWSRUWV WRWKHLQOHWSRUW7KHUHYHUVHÀRZLVQRWSUHVVXUHFRPSHQVDWHG MODEL RD-300 3523257,21$/',9,'(5 :,7+)5((5(7851&+(&.6 VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ :HLJKW5',EV 5',EV STANDARD MODELS AVAILABLE MODEL NUMBER RD-237-8 RD-250-16 RD-275-30 RD-208-8 RD-212-30 RD-337-8 RD-350-16 RD-375-30 RD-308-8 RD-312-30 DIVIDER RATIO PORT SIZE INLET FLOW RANGE 137) 137) 137) 6$( 6$( *30 *30 *30 *30 *30 RD-350-AB-16 RD-375-AB-30 MODEL RD-500P 3523257,21$/',9,'(5 :,7+$'-867$%/(25,),&( 7KH 35,1&( PRGHO 5'3 LV D SUHVVXUH FRPSHQVDWHG SURSRUWLRQDO ÁRZ GLYLGHU YDOYHZLWKRQHÀ[HGDQGRQHDGMXVWDEOHRULÀFH7KLVYDOYHSURYLGHVWKHVDPHIXQFWLRQ DVWKH5'H[FHSWWKHGLYLGHUUDWLRFDQEHFKDQJHGLQWKHÀHOG VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ :HLJKW5'3,EV STANDARD MODELS AVAILABLE MODEL NUMBER RD-537P-8 RD-550P-16 RD-575P-30 MODEL RD-1000S ,17(51$//<3,/27(' 6(48(1&(9$/9(:,7+ (;7(51$/'5$,1 PORT SIZE 137) 137) 137) INLET FLOW RANGE *30 *30 *30 7KH35,1&(YDOYHPRGHO5'6LVDQLQWHUQDOO\SLORWHGDGMXVWDEOHVHTXHQFHYDOYH 7KLVYDOYHZLOOSUHYHQWWKHÁRZRIRLOIURPJRLQJWRWKHVHTXHQFHSRUWXQWLOWKHSUHVVXUH RQWKHLQOHWSRUWUHDFKHVWKHVHTXHQFHSUHVVXUH7KHVHTXHQFHSUHVVXUHLVDGMXVWDEOH ZLWKLQWKHUDQJHJLYHQLQFKDUWEHORZ$EXLOWLQFKHFNYDOYHDOORZVÁRZIURPVHTXHQFH SRUWWRLQOHW7RRSHUDWHSURSHUO\WKHdrain port must be connected to tank.7KLV YDOYHLVDVSRROW\SHVHTXHQFHYDOYHDQGZLOOSURYLGHVPRRWKRSHUDWLRQEXWVKRXOGQRW EHXVHGLQDSSOLFDWLRQVWKDWUHTXLUHORZOHDNDJH VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ :HLJKW,EV STANDARD MODELS AVAILABLE MODEL NUMBER RD-1050S___ RD-1075S___ PORT SIZE INLET AND SEQUENCE DRAIN PORT 137) 137) 137) 137) 635,1* 6(48(1&( 35(6685( / 0 + 36, 36, 36, 7RFRPSOHWHWKHPRGHOQXPEHUÀOOLQWKHEODQNZLWKWKHVSULQJOHWWHUWKDWFRUUHVSRQGVWRGHVLUHGFRXQWHU EDODQFHSUHVVXUHUDQJHEXAMPLE:5'60IRUSVLVSULQJUDQJH 6WDQGDUGVHWWLQJVDUHSVLSVLDQGSVLIRUUDQJHV/0DQG+UHVSHFWLYHO\ CATV 65-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 22 & 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES ,Q2(0TXDQWLWLHVWKH5'DQG5'YDOYHVDUHDYDLODEOHZLWKVSHFLDOGLYLGHUUDWLRV5DWLRVDYDLODEOH DUHDQGRWKHUVDVUHTXLUHG:KHQRUGHULQJVSHFLI\WKHGLYLGHUUDWLRDIWHUWKHPRGHO QXPEHU(;$03/(5' MODEL RD-200, RD-300, RD-300AB, RD-500P, AND RD-1000S PARTS BREAKDOWN AND DIMENSIONS .38 OUTLET P (PSI) 210 180 150 6 120 0-1 /30 90 0 20 60 RD 30 0 0 3 6 9 12 15 18 21 24 27 30 FLOW (GPM) .912 .265 DIA (2) 1.00 240000912 SYMBOL 00 1.75 .88 4.63 3.88 OUTLET 2.05 -30 RD-200 OUT 20 0/3 OUT RD 4.13 RD 20 0/3 00 -8 671600002 IN VALVE BODY INLET 2.31 DIVIDER SPOOL SEAL KIT NO. 660502001 RD-300 SEE DETAIL AT RIGHT 200018001 670804001 670300010 230009016 240000912 OUT SYMBOL OUT RD 300 AB ONLY 671600002 The RD-300AB valve has a built-in automatic bypass. This allows oil to crossover from one outlet to the other when the pressure difference between the two outlet reaches 750 PSI. 660203001 VALVES INLET RD-200 VALVE BODY DIVIDER SPOOL IN SEAL KIT NO. 660503001 RD-300 & RD-300-AB RD-500P SYMBOL 240000912 OUT 671600002 OUT IN RD-500P 660305001 INLET RD-1000S VALVE BODY DIVIDER SPOOL 660310003 SEAL KIT NO. 660505001 SYMBOL SECONDARY PORT TANK PORT IN 240000912 240000015 671100007 ADJUSTMENT SCREW 671800001 220000765 220001302 METERING SPRING 9 T 671000011 VALVE BODY SPOOL INLET RD-1000S SECONDARY 660203001 SEAL KIT NO. 660510001 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 66-07-13-02 DIFFERENTIAL POPPET STYLE RELIEF VALVES - RV AND DRV SERIES MODEL RV ',))(5(17,$/3233(7 ,1/,1(5(/,() 7KH35,1&(YDOYHPRGHO59LVDGLIIHUHQWLDOSRSSHWW\SHLQOLQHUHOLHI 7KHYDOYHLVPDGHXSRIDUHOLHIFDUWULGJHDQGDFDVWLURQYDOYHERG\7KH GLIIHUHQWLDOSRSSHWW\SHUHOLHISURYLGHVVPRRWKTXLHWSHUIRUPDQFHZLWKD PLQLPXPYDULDWLRQEHWZHHQFUDFNLQJDQGIXOOÁRZSUHVVXUHV7KLVW\SH UHOLHILVDOVROHVVVHQVLWLYHWRV\VWHPFRQWDPLQDWLRQ7KHPRGHO59LV ZHOOVXLWHGDVDV\VWHPUHOLHIXSWR*30DQGSVL,WLVDYDLODEOH LQ WZR SUHVVXUH UDQJHV DQG ERWK DQ H[WHUQDOO\ DGMXVWDEOH DQG VKLP DGMXVWDEOHYHUVLRQ VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ:HLJKW,EV 3UHVVXUHSVLPD[ MODEL DRV ',))(5(17,$/3233(7 '28%/(5(/,() VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ MODEL RV-O ',))(5(17,$/3233(7 5(/,()&$575,'*( VALVES 7KH35,1&(YDOYHPRGHO'59LVDGLIIHUHQWLDOSRSSHWW\SHGRXEOHUHOLHI 7KLVYDOYHXVHVWKHVDPHUHOLHIFDUWULGJHDVWKHPRGHO597KHGRXEOH UHOLHILVXVHGLQV\VWHPVWKDWUHTXLUHFURVVRYHUUHOLHISURWHFWLRQVXFKD UHYHUVLEOHK\GUDXOLFPRWRURUV\VWHPVWKDWUHTXLUHDFXVKLRQYDOYHVXFK DVGRXEOHDFWLQJF\OLQGHUV :HLJKWOEV 7KH35,1&(YDOYHPRGHO59LVWKHGLIIHUHQWLDOSRSSHWUHOLHIFDUWULGJH XVHGLQPDQ\YDOYHPRGHOV,WLVDYDLODEOHSUHVHWWRLQVWDOOLQWR59YDOYHVLQ WKHÀHOGRULQWRDFXVWRPDSSOLFDWLRQ7KLVUHOLHIFDUWULGJHFDQDOVREHXVHG LQWKH5'5'5'DQG69VWDFNYDOYHLQOHWVHFWLRQ VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ STANDARD MODELS AVAILABLE MODEL NUMBER MODEL NUMBER VALVE TYPE RELIEF SETTING PORT SIZE RV-1H DRV-1HH $'-867$%/(36, 36,#*30 6$( RV-2H DRV-2HH $'-867$%/(36, 36,#*30 µ137) RV-4H DRV-4HH $'-867$%/(36, 36,#*30 µ137) RV-2L DRV-2LL $'-867$%/(36, 36,#*30 µ137) CATV 67-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 & 24 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 MODEL RV AND DRV SPECIAL MODELS AND MOUNTING DIMENSIONS RV SPECIAL MODEL RV RELIEF VALVES 2WKHUUHOLHIYDOYHPRGHOVQRWOLVWHGRQSUHYLRXV SDJHDUHDYDLODEOHLQ2(0TXDQWLWLHV7RVHOHFWD PRGHOQXPEHUXVHWKHRUGHUFRGHPDWUL[VKRZQ DWULJKW&RQVXOWDVDOHVUHSUHVHQWDWLYHLIRSWLRQV RWKHUWKDQWKRVHOLVWHGDUHUHTXLUHG MODEL NUMBER PORT SIZE RELIEF TYPE PRESSURE SETTING RV 1 - #12 SAE 2 - 3/4 NPTF 3 - #10 SAE 4 - 1/2 NPTF 5 - #8 SAE H- Adjustable 1500-3000 PSI L- Adjustable 500-1500 PSI NH- Non-Adjustable 1500-3000 PSI NL- Non-Adjustable 500-1500 PSI Specify Relief Pressure in PSI. Leave Blank for Standard Setting O - Cartridge Only. No Body. SPECIAL MODEL DRV RELIEF VALVES 2WKHUUHOLHIYDOYHPRGHOVQRWOLVWHG RQSUHYLRXVSDJHDUHDYDLODEOHLQ 2(0TXDQWLWLHV7RVHOHFWDPRGHO QXPEHU XVLQJ WKH RUGHU FRGH PDWUL[ DW ULJKW &RQVXOW D VDOHV UHSUHVHQWDWLYH LI RSWLRQV RWKHU WKDQWKRVHOLVWHGDUHUHTXLUHG DRV XX MODEL NUMBER PORT SIZE DRV 1 - #12 SAE 2 - 3/4 NPTF 3 - #10 SAE 4 - 1/2 NPTF 5 - #8 SAE RELIEF TYPE Port A/B #1 H- Adjustable 1500-3000 PSI L- Adjustable 500-1500 PSI NH- Non-Adjustable 1500-3000 PSI NL- Non-Adjustable 500-1500 PSI Relief Settings: The two digits represent the relief settings in 100s to the nearest 100 PSI for the respective ports. EXAMPLE: 08 = 800 PSI 17 = 1700 PSI AT VARIOUS SET POINTS. 110 SUS OIL AT 115°F. 1.50 1.25 PRESSURE 2.50 2.78 3000 0.94 1.22 2500 TANK PORT PRESSURE PORT (2) PRESSURE (PSI) VALVES RV-SERIES RELIEF CURVES 0.28 DIA. (2) 1.62 XX RELIEF SETTINGS (PSI) Port A/B Port C/D Port C/D #2 H- Adjustable 1500-3000 PSI L- Adjustable 500-1500 PSI NH- Non-Adjustable 1500-3000 PSI NL- Non-Adjustable 500-1500 PSI RV-SERIES MOUNTING DIMENSIONS 3.25 STANDARD SETTING 2000 PSI for H and NH 1000 PSI for L and NL 5.06 DRV-SERIES MOUNTING DIMENSIONS RELIEF CARTRIDGE FOR A/B PASSAGE RELIEF CARTRIDGE FOR C/D PASSAGE 0.343 DIA. (2) 2000 1500 1000 B D 500 4.50 3.50 2.88 1.63 2.00 A C 1.13 0 0.50 3.44 5 25 NO. 10 SAE PORT 7/8-14 UNF-2B X .625 DEEP TANK CAVITY 1.280 1.13 DIA .687 DIA. .690 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 24 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 1.637 PRESSURE 30° 127(7+(6(&$575,'*(6$5(7+(6$0(21%27+59$1''599$/9(6 9 20 MACHINING DIMENSIONS FOR RELIEF VALVE CARTRIDGE 7.00 FIELD CONVERSION KITS: $'-5(/,()&$575,'*(36,5921/< $'-5(/,()&$575,'*(36, 121$'-867$%/(5(/,()&$575,'*(36,5921/< 121$'-867$%/(5(/,()&$575,'*(36, $'-5(/,()&$575,'*(36,'5921/< 121$'-867$%/(5(/,()&$575,'*('5921/< 596($/.,7 '596($/.,7 36,5(/,()635,1* 36,5(/,()635,1* 10 15 FLOW (GPM) CATV 68-07-13-02 MODEL RD-1800 PRESSURE RELIEF MODEL RD-900 SELECTOR VALVE MODEL RD-1800 %$//635,1*7<3( ',5(&7$&7,1*5(/,() 7KH35,1&(YDOYHPRGHO5'LVDGLUHFWDFWLQJEDOOVSULQJW\SHSUHVVXUH UHOLHI 7KH YDOYH LV FRPSDFW DQG VLPSOH LQ GHVLJQ 7KLV W\SH UHOLHI LV IDVW RSHQLQJDQGLVZHOOVXLWHGIRUSUHVVXUHVSLNHSURWHFWLRQ7KHSHUIRUPDQFH FXUYHVEHORZLQGLFDWHWKHORZFUDFNLQJSUHVVXUHW\SLFDOWREDOOVSULQJUHOLHIV 3OHDVHUHIHUWRWKHPRGHO59UHOLHIIRUDV\VWHPSUHVVXUHUHOLHI7KHYDOYHLV DYDLODEOHZLWKDVWDQGDUGVWHHOVHDWPRGHO5'6RUZLWKDKDUGHQHG VHDWPRGHO5'+%RWKPRGHOVDUHH[WHUQDOO\DGMXVWDEOH SYMBOL VALVE SPECIFICATIONS: &DSDFLW\JSPPD[LQOHWÁRZ 3UHVVXUHSVLPD[ :HLJKW,E $GMXVWPHQW5DQJH36,WR36, RELIEF VALVE CURVE P RD-1800 AT VARIOUS SET POINTS 110 SUS OIL AT 115°F. 2000 T 1800 1600 4.56 PRESSURE PORT (2) .69 1200 1000 TANK 1.50 800 600 RD-1800H 400 2.13 RD-1800S 200 0 4 8 12 16 20 FLOW (GPM) 671500004 671800002 671900001 24 1.50 671800010 670300011 230009014 STANDARD MODELS AVAILABLE MODEL # PORT SIZES MAX FLOW RD-1837S RD-1850H RD-1850S RD-1875S 137) 137) 137) 137) *30 *30 *30 *30 MODEL RD-900 6(/(&7259$/9( NOTE:5HOLHIVHWWLQJVDUH36,#*30 )RUQRQVWDQGDUGUHOLHIVHWWLQJVVSHFLI\36,LQ KXQGUHGVDQG*30DIWHUPRGHOQXPEHU EX:5'612-10IRU1200 PSI @ 10 GPM 7KH 35,1&( YDOYH PRGHO 5' LV D PDQXDO ZD\ SRVLWLRQ VHOHFWRUYDOYH7KLVYDOYHZLOODOORZRQHSXPSVRXUFHWRVXSSO\WZR VHSDUDWHFLUFXLWV3XVKLQJWKHKDQGOHLQGLYHUWVRLOÁRZWRSRUWDZD\ IURP KDQGOH 3XOOLQJ WKH KDQGOH RXW GLYHUWV RLO ÁRZ WR SRUW QHDUHVW KDQGOH VALVE SPECIFICATIONS &DSDFLW\ JSPPD[LQOHWÁRZ 3UHVVXUH SVLPD[ :HLJKW OEV .87 STANDARD MODELS 02'(/ 32576,=(6 5' 5' 137) 137) SYMBOL 4.49 3.88 2.05 OUTLETS .31 1.75 RD-900 .91 .265 DIA (2) 4.13 230017018 240016074 240016071 INLET 2.25 6($/.,7 CATV 69-07-13-02 VALVES PRESSURE (PSI) 1400 190100019 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 SINGLE SELECTOR VALVE MODEL SS SELECTOR 7KH35,1&(YDOYHPRGHO66LVDPDQXDOZD\SRVLWLRQVHOHFWRUYDOYH7KLV YDOYHZLOODOORZRQHSXPSVRXUFHWRVXSSO\WZRFLUFXLWV:LWKWKHVWDQGDUGVHOHFWRU VSRROSXOOLQJWKHVSRRORXWGLYHUWVRLOWRSRUWQHDUHVWKDQGOHSXVKLQJWKHVSRRO LQGLYHUWVRLOWRWKHSRUWDZD\IURPWKHKDQGOH7KHYDOYHKDVDQLQOHWRQERWKWKH ERWWRPDQGIURQWRIWKHYDOYHERG\6SHFLDORSWLRQVLQFOXGHOHYHUKDQGOHDQGD ÁRDWVSRRO7KHÁRDWVSRROFRQQHFWVWKHLQOHWWRERWKRXWOHWVZKHQWKHVSRROLV SXVKHGLQDQGEORFNVERWKRXWOHWVZKHQVSRROLVSXOOHGRXW VALVE SPECIFICATIONS: &DSDFLW\ 3UHVVXUH :HLJKW KITS: (1'&$3.,7 /(9(5+$1'/(.,7 6($/.,7 .12%3$5712 61$35,1*3$5712 &/(9,63$5712 635,1*2))6(7.,7 JSPPD[LQOHWÁRZ SVLPD[ OEV SYMBOL STANDARD MODELS AVAILABLE MODEL NUMBER PORT SIZE SS-2A1D SS-3A1D SS-2A1A SS-2A1E SS-2A1B SS SELECTOR SPOOL 137) 6$( 137) 137) 137) DESCRIPTION 6(/(&725:,7+.12%+$1'/( 6(/(&725:,7+.12%+$1'/( 6(/(&725:,7+287$77$&+0(176 6(/(&725:,7+/(9(5+$1'/( 6(/(&725:,7+&/(9,6 SS VALVES SS FLOAT SPOOL SPECIAL MODEL SS SELECTOR VALVES 2WKHU VHOHFWRU YDOYHV QRW OLVWHG DV VWDQGDUG DERYH DUHDYDLODEOHLQOEM quantities7RVHOHFWDPRGHO QXPEHUXVHWKHRUGHUFRGHPDWUL[DWULJKW&RQVXOWD VDOHVUHSUHVHQWDWLYHLIRSWLRQVRWKHUWKDQWKRVHOLVWHG DUHUHTXLUHG MODEL PORT SIZE SPOOL SPOOL ATTACHMENTS HANDLE SS 1-3/8 NPTF 2-1/2 NPTF (standard) A SELECTOR (standard) 3-#8 SAE 4-#10 SAE B FLOAT 1-NONE (standard) 2-END CAP ONLY 3-SPRING OFFSET, SPOOL OUT 4-HEAVY SPRING OFFSET, SPOOL OUT A-NONE B-CLEVIS ONLY C-CLEVIS W/ PINS AND LINK D-KNOB (standard) E-LEVER HANDLE R-ROLLER (use w/attachment 4) PARTS BREAKDOWN AND DIMENSIONS 3.56 1.63 MODEL SS LEVER HANDLE OPTION E 5.32 .,712 .97 .25 WIDE CLEVIS 3.25 2.25 1.00 1.63 OPTION 'D' (KNOB) 1.19 .343 DIA (2) BOTTOM INLET LOCATION 1.06 2.13 .38 SPOOL TRAVEL .187 DIA PINS ROLLER MAY BE MOUNTED VERTICAL OR HORIZONTAL FRONT INLET LOCATION 2.08 KNOB OPTION D 3$5712 OPTION 'R' (ROLLER) 'A' REF 1.98 SPOOL OUT 1.65 SPOOL IN (1.60 MAX SPOOL IN); 15° APPROACH ANGLE @ SPOOL IN 9 1.45 5.10 'A' 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 & 24 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 70-07-13-02 MODEL DS DOUBLE SELECTOR VALVE 7KH 35,1&( YDOYH PRGHO '6 LV D PDQXDO ZD\ SRVLWLRQ GRXEOH VHOHFWRU YDOYH 7KLV YDOYH ZLOO GLYHUW WKH Á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ÁRZ 3UHVVXUH SVL :HLJKW OEV STANDARD MODELS AVAILABLE PORT SIZE '6$( 137) '28%/(6(/(&725:,7+/(9(5+$1'/( '6$( 6$( '28%/(6(/(&725:,7+/(9(5+$1'/( '6$' 137) '28%/(6(/(&725:,7+.12%+$1'/( '6$$ 137) '28%/(6(/(&725:,7+287$77$&+0(176 '6$( 137) '28%/(6(/(&725:,7+/(9(5+$1'/( DESCRIPTION 63(&,$/ 02'(/ '6 6(/(&725 9$/9(6 2WKHU GRXEOH VHOHFWRU YDOYHV QRW OLVWHG DV VWDQGDUG DUH DYDLODEOHLQ2(0TXDQWLWLHV7RVHOHFWDPRGHOQXPEHU XVH WKH RUGHU FRGH PDWUL[ EHORZ &RQVXOW D VDOHV UHSUHVHQWDWLYH LI RSWLRQV RWKHU WKDQ WKRVH OLVWHG DUH UHTXLUHG DS 2 POSITION DETENT OPTION 4 SPRING OFFSET (SPOOL OUT) OPTION 3 MODEL PORT SIZE SPOOL TYPE DS 1 - 1/2 NPTF 2 - #8 SAE 3 - #10 SAE 4 - 3/4 NPTF (standard) 5 - #12 SAE 6 - 1 NPTF A SELECTOR (standard) KNOB OPTION D 2.13 B SERIES/ PARALLEL SPOOL ATTACHMENTS 1 - NONE (standard) 2 - END CAP ONLY 3 - SPRING OFFSET SPOOL OUT 4 - 2 POSITION DETENT HANDLE A - NONE B - CLEVIS ONLY C - CLEVIS W/ PINS AND LINK D - KNOB E - LEVER HANDLE (standard) CYLINDER #1 PORTS .38 A 2.13 4.25 INLET PORTS E C SYMBOL SELECTOR SPOOL D BAFE 3.25 .406 DIA. (2) CD B CYLINDER #2 PORTS CIRCUIT SELECTOR F 2.75 5.50 .187 DIA. PIN .25 WIDE CLEVIS 3.25 1.13 CATV 71-07-13-02 CIRCUIT SELECTOR SERIES/PARALLEL 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 & 24 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING 9 VALVES MODEL # KITS: /(9(5+$1'/( 635,1*2))6(7.,7 326,7,21'(7(17.,7 (1'&$3.,7 6($/.,7 .12%3$5712 61$35,1*3$5712 &/(9,63$5712 PILOT-OPERATED CHECK VALVES 7KH35,1&(YDOYHPRGHO5'LVDGRXEOHSLORWRSHUDWHGORFNYDOYH 7KLVYDOYHZLOOORFNDF\OLQGHULQSODFHZKHQDGLUHFWLRQDOFRQWUROYDOYHLV LQWKHQHXWUDOSRVLWLRQ,QRSHUDWLRQRLOLVGLUHFWHGWRRQHRIWKHYDOYHSRUWV DQGRLOFDQIUHHÁRZWRWKHFRUUHVSRQGLQJF\OLQGHUSRUW7KHSUHVVXUHRQ WKLVYDOYHSRUWZLOOVKLIWWKHSLORWVSRRORSHQLQJWKHRSSRVLWHFKHFNYDOYH 7KLVZLOODOORZRLOWRUHWXUQWKURXJKWKHRSSRVLWHFKHFNYDOYH7KLVYDOYHKDV DKDUGHQHGVWHHOVHDWDQGVWHHOEDOODQGWKHUHIRUHVKRXOGQRWEHXVHGLQ DSSOLFDWLRQVUHTXLULQJDEVROXWHO\]HUROHDNDJH:KHQXVLQJDSLORWRSHUDWHG FKHFNWRORZHUDKHDY\ORDGWKHYDOYHPD\FKDWWHU$QRULÀFHLQWKHOLQHLQ VRPHFDVHVPD\EHEHQHÀFLDO MODEL RD-1400 /2&.9$/9('28%/( 3,/2723(5$7(' 5.88 3.50 1.81 TO CYLINDER CYLINDER PORTS 3.11 2.00 660214001 TO CONTROL VALVE .266 DIA (3) RD-1400 1.56 1.94 STANDARD MODELS AVAILABLE VALVES MODEL NUMBER PORT SIZE RD-1450 RD-1475 137) 137) VALVE PORTS 3.88 VALVE SPECIFICATIONS: &DSDFLW\ JSPPD[LQOHWÁRZ 3UHVVXUH SVLPD[ :HLJKW OEV 3LORW5DWLR 7KH35,1&(YDOYHPRGHO5'LVDSLORWRSHUDWHGFKHFNYDOYH7KLVYDOYH EORFNVRLOIURPÁRZLQJIURPWKHF\OLQGHUSRUWWRWKHYDOYHSRUWXQWLOVXIÀFLHQW SUHVVXUHLVDSSOLHGWRWKHSLORWSRUW2LOFDQIUHHÁRZIURPWKHYDOYHSRUWWR WKHF\OLQGHUSRUW7KHYDOYHKDVDWZRVWDJHSRSSHWDOORZLQJVPRRWKFKDWWHU IUHHRSHUDWLRQ MODEL RD-1600 3,/2723(5$7(' &+(&.9$/9( 5.81 240000016 240019016 PILOT PORT 240000018 240019018 670200004 670300012 CYLINDER PORT CYLINDER 2.50 1.31 PILOT PRESSURE IN RD-1600 VALVE PORT VALVE SPECIFICATIONS: &DSDFLW\ JSPPD[LQOHWÁRZ 3UHVVXUH SVLPD[ :HLJKW OEV 3LORW5DWLR 'HFRPSUHVVLRQ5DWLR 9 .281 DIA. (2) 2.91 1.50 671100014 670100006 180900147 STANDARD MODELS AVAILABLE MODEL NUMBER VALVE AND CYL. PORT PILOT PORT RD-1637 137) 137) RD-1650 137) 137) RD-1608 6$( 6$( 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; SEE PAGE 23 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 72-07-13-02 MISCELLANEOUS INFORMATION +\GUDXOLF)OXLG²$JRRGTXDOLW\PLQHUDOEDVHGK\GUDXOLFÁXLGLVUHFRPPHQGHG$Q\ÁXLGXVHG PXVWEHFRPSDWLEOHZLWKWKH%81$16HDOVW\SLFDOO\XVHGLQWKHVWDQGDUGYDOYHV )LOWUDWLRQ ² )RU JHQHUDO SXUSRVH YDOYHV ÁXLG FOHDQOLQHVV VKRXOG PHHW WKH ,62 OHYHO)RUH[WHQGHGOLIHRUIRUSLORWRSHUDWHGYDOYHVWKHÁXLGFOHDQOLQHVV LVUHFRPPHQGHG 7KUHDG6HDODQW²8VHRIDTXDOLW\QRQ7HÁRQWKUHDGVHDODQWLVUHFRPPHQGHGIRUWDSHUHG SLSHWKUHDGVXVHRI7HÁRQWDSHLVQRWUHFRPPHQGHG MISC. HYDRAULIC FORMULA AND DESIGN INFORMATION F\OLQGHUDUHDVTLQ F\OLQGHUGLDLQFKHV[ F\OLQGHUIRUFHOEV F\OLQGHUDUHDVTLQ[SVL F\OLQGHUVSHHGLQVHF [JSPF\OLQGHUDUHD K\GUDXOLFKRUVHSRZHU SVL[JSP KSWRGULYHDSXPS SVL[JSP[SXPSHIÀFLHQF\ K\GUDXOLFPRWRUKS WRUTXHLQOEV[USP K\GUDXOLFPRWRUWRUTXH KRUVHSRZHU[USP K\GUDXOLFPRWRUVSHHGUSP [JSPFXELFLQSHUUHY KRUVHSRZHULVHTXLYDOHQWWR ZDWWVRUNLORZDWWV %78KRXURU%78PLQ IWOEVVHFRUIWOEVPLQ PRESSURE DROP ACROSS AN ORIFICE ,QWKHFKDUWEHORZJLYHVWKHDSSUR[LPDWHSUHVVXUHGURSLQSVLDFURVVDQRULÀFH7KLV FKDUWFDQEHXVHGIRUK\GUDXOLFRLORQO\ 2UL¿FH6L]H ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² GPM HYDRAULIC CYLINDER FORCE (lbs.) CYL. 500 1000 AREA PSI PSI 1500 2000 PSI PSI PSI 100 IRUFHOEV F\OLQGHUDUHDVTLQ[SUHVVXUHSVL 7RGHWHUPLQHIRUFHGHYHORSHGE\DF\OLQGHULQ H[WHQVLRQXVHFKDUWEHORZ7RGHWHUPLQHIRUFH GHYHORSHGLQUHWUDFWVXEWUDFWWKHIRUFHWKDW FRUUHVSRQGVWRF\OLQGHUSLVWRQURGGLDPHWHU CYL. DIA ² ² 2500 3000 PSI PSI ² ² ² ² ² ² ² PSI PSI 200 250 LQWR LQFKHV LQFKHV LQFKHV PHWHUV FHQWLPHWHUV PLOOLPHWHUV JDOORQV OLWHUV SVL EDU DWP NJFP EDU DWP LQKJ SVL NJFP DWP FXELFLQFKHV JDOORQV NJP IWOEV PXOWLSO\E\ MOTOR HORSEPOWER TO DRIVE A HYDRAULIC PUMP 3XPS(IÀFLHQF\)RUPXOD+3 *30[36,[(IÀFLHQF\ PSI 300 PSI 400 PSI 500 PSI 750 PSI 1000 PSI 1250 PSI 1500 PSI 2000 PSI 2500 PSI 3000 PSI 4000 HYDRAULIC CYLINDER SPEED (inches/second) F\OLQGHUVSHHGLQFKHVVHFRQG [*30F\OLQGHUDUHDVTLQ 7KHFKDUWEHORZJLYHVF\OLQGHUVSHHGLQLQFKHVSHUVHFRQGIRUH[WHQGDQGUHWUDFWIRUDJLYHQURGGLDPHWHU7RGHWHUPLQHWKHQXPEHURIVHFRQGVLWZLOOWDNHWR H[WHQGRUUHWUDFWWKHF\OLQGHUGLYLGHWKHVWURNHOHQJWKLQFKHVE\WKHF\OLQGHUVSHHG(;IRUD[F\OLQGHUZLWKJSPVSHHGLVLQFKHVVHF 7KHWLPHWRH[WHQGLQFKHVZLOOEHVHFRQGV *30 ',$ ',$ ',$ ',$ ',$ ',$ ',$ ',$ ',$ ',$ (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 (;7 5(7 52' 52' 52' 52' 52' 52' 52' 52' 52' 52' ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² CATV 73-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; 9 VALVES GPM 7RFRQYHUW PHWHUV FHQWLPHWHUV PLOOLPHWHUV LQFKHV LQFKHV LQFKHV OLWHUV JDOORQV NJFP NJFP NJFP SVL SVL SVL SVL EDU EDU EDU JDOORQV FXELFLQFKHV IWOEV NJP KVakZFj^X`GZ[ZgZcXZ<j^YZ EVg`Zg$<gZhZcidEg^cXZBVcj[VXijg^c\ Parker/Gresen Models: V20, V10, SP, SPK, 300, 400 & Accessory PARKER/GRESEN V20 Parallel Work Sections 20-10-4 With K-20-VH-B Handle 20-50-4 With K-20-VH-B Handle 20-10-4 With K-20-VH-B Handle and Two RC-2550 Work Port Reliefs 20-50-K4 With K-20-VH-B Handle VALVES 20-10-DF4 With K-20-VH-B Handle Tandem Work Sections 20T-10-04 With K-20-VH-B Handle Parallel Lock Sections With Pilot Operated Checks 20-10-L04 With K-20-VH-B Handle Inlet Sections (Left Cover) 20-LC-12 With WH-2550 Relief 20-LC-75 With WH-2550 Relief and K-WH-A Adjusted Kit Outlet Sections (Right Cover) 20-RC-12-E 20-RC-75-E-MY With K-20-50-Y Power Beyond Kit PARKER/GRESEN V10 Parallel Work Sections V10 Is Not Available With Economical Handle 10-8N-04 With K-10-VH Handle 10-8-04 With K-10-VH Handle and Two RP10A-3000 Adjustable Work Port Reliefs 10-8N-K4 With K-10-VH Handle 10-8N-F4 With K-10-VH Handle 10-08-03-SOL-I-12 and Two Solenoid Cartridges and Coils Series Work Sections V10 Does Not Have a Standard Series Work Section Parallel Lock Sections With Pilot Operated Checks V10 Does Not Have a Standard Lock Section With Pilot Operated Checks Inlet Sections (Left Cover) 10-LC10 With RCMA-3000 Relief Outlet Sections (Right Cover) 10-RC-10-EY 9 Prince Manufacturing Models: Series 20, SV, RD5000, RD2500 & Accessory PRINCE SERIES 20 STACKABLE VALVE Parallel Work Sections 20 GPM 3500 PSI 20P1BA1AA 4 Way 3 Position, #10 SAE Ports 20P4BA1AA 4 Way 3 Position, 1/2” NPTF Ports 20P1BA1EE 4 Way 3 Position, #10 SAE Ports With 2500 PSI Work Port Reliefs Float Work Sections 20P4DD1AA 4 Way 4 Position With Float, 1/2” NPTF Ports Motor Spool Work Sections 20P1CB1AA 4 Way 3 Position, #10 SAE Ports Tandem Work Sections 20T1BA1AA 4 Way 3 Position, #10 SAE Ports Parallel Lock Sections With Pilot Operated Checks 20L1CA1 4 Way 3 Position, #10 SAE Ports Inlet Sections (Left Cover) 20I2E #12 SAE Ports, Non Adjusted Relief 20I3J 3/4” NPTF Ports, Adjusted Relief Outlet Sections (Right Cover) 20E21 #12 SAE Ports 20E32 3/4” NPTF Ports, Power Beyond See Series 20 Valve In Catalog, or on www.princehyd.com PRINCE SV STACKABLE VALVE Parallel Work Sections 12 GPM 3000 PSI SVW1BA1 4 Way 3 Position, #8 SAE Ports, Standard Handle SVW1BA11 4 Way 3 Position, #8 SAE Ports, Enclosed Handle SVH1BA11GG 4 Way 3 Position, #8 SAE Ports, Enclosed Handle, Work Port Reliefs Float Work Sections SVW1DD11 4 Way 4 Position, With Float #8 SAE Ports, Enclosed Handle Motor Spool Sections SVW1CA11 4 Way 3 Position, #8 SAE Ports, Enclosed Handle Solenoid Sections (On-Off Operation) SVW1BA-T12Q 4 Way 3 Position, #8 SAE Ports, 12 Volt Solenoid Coils Series Work Sections SVS1GA1AA 4 Way 3 Position, #8 SAE Ports, Series Circuit, Work Port Relief Plugs Parallel Lock Sections With Pilot Operated Checks SLV1CA1 Double P.O. Checks, #8 SAE Ports, 4 Way 3 Position Motor, Spring Center Inlet Sections (Left Cover) SV125 #10 SAE Ports, Adjusted Relief Outlet Sections (Right Cover) SVE21 #10 SAE Ports, Convertible to Power Beyond or Closed Center See SV Valve In Catalog, or on www.princehyd.com 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; CATV 74-07-13-02 PARKER/GRESEN SP Series PRINCE VALVE RD5000 Series 1,2,3 SPOOL MONO-BLOCK 30 GPM – 3000 PSI SP-4-HP, SPX-4-HP RD512CA5A4B1 SPK-4-HP RD512GC5A4B1 SP-4-4-HP, SPX-4-4-HP RD522CCAA5A4B1 SPK-4-4-HP RD522GCGA5A4B1 SP-4-4-4-HP, SPX-4-4-4-HP RD532CCCAAA5A4B1 SPK-4-4-4-HP RD532GCCGAA5A4B1 4 Way 3 Position, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 4 Position with Float Detent, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 3 Position, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 4 Position with 1st Spool Float Detent, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 3 Position, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 4 Position with 1st Spool Float Detent, 3/4” In & Out, 1/2” Work Ports, Spring Center 300/400 Series RD2500 Series 300 400 410 RD2575-T3-ESA1 RD2575-T4-ESA1 RD2575-T4-EDA1 410-40 RD2575-M4-EDA1 3 Way 3 Position, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 3 Position, 3/4” In & Out, 1/2” Work Ports, Spring Center 4 Way 3 Position Detent, 3/4” In & Out, 1/2” Work Ports 4 Way 3 Position Detent, Motor Spool, 3/4” In & Out, 1/2” Work Ports CFD-10-5-NR CFD-10-6-HP CFD-50-3-HP CFD-50-4 CFD-50-8 CFD-50-10-HP CFD-75-2-HP CFD-75-3-HP CFD-75-3-NR CFD-75-5-NR CFD-75-10-NR CFD-A-50 CFD-A-75 CFQ-A-50 CFQ-A-75R DC25A-75-0-NR DS-12 DS-75 DWV-12-25 DWV-50-A-12 DWV-50-20 DWV-75-A DWV-75-20 HM-50 JT-50-HP, JL-50-HP LD1-50-1S LO-50-D PD-12-50 PD-50-50-50 PD-50-60-40 PD-75-50-50 S-50 S-75 SM-50, S-50 SM-8 WJL-10-A WJL-50-13 WJL-50-20 RD-412-5 RD-412-R-6 RD-400-R-3 RD-400-R-4 RD-450-R-8 RD-400-R-10 RD-405-R-2 RD-405-R-3 RD-405-3 RD-405-5 RD-405-10 RD-550 RD-575 RD-150-16, RD-1950-16 RDRS-175-30, RDRS-1975-30 RD-575-P-30 DS-4A1D DS-5A1D DRV-1NHNH-2500 DRV-4LL-12-12 DRV-4NHNH-2000 DRV-2HH DRV-2NHNH-2000 SS-2B1B RD-1850H RD-1650 RD-1450 RD-212-30 RD-250-16 RD-250-16(60/40) RD-275-30 RD-950 RD-975 SS-2A1D, RD-950 SS-3A1D RV-3H RV-4L RV-4H Constant Volume Priority Flow Divider, #12 Ports Constant Volume Priority Flow Divider, #12 Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 1/2” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Constant Volume Priority Flow Divider, 3/4” Ports Screw Adjust Priority Flow Control, 1/2” Ports Screw Adjust Priority Flow Control, 3/4” Ports Lever Adjust Priority Flow Control, 1/2” Ports Lever Adjust Priority Flow Control, 3/4” Ports, Adjustable Relief Screw Adjust Priority Flow Control, 3/4” Ports Double Selector, 3/4” Ports Double Selector, #12 Ports Double Cross-Over Relief (Cushion), #12 Ports Double Cross-Over Relief (Cushion), 1/2” Ports Double Cross-Over Relief (Cushion), 1/2” Ports Double Cross-Over Relief (Cushion), 3/4” Ports Double Cross-Over Relief (Cushion), 3/4” Ports Two Position Float Valve, 1/2” Ports Adjustable Relief (Ball Spring), 1/2” Ports Single Lock Valve, 1/2” Ports Double Lock Valve, 1/2” Ports Proportional Flow Divider, #12 Ports Proportional Flow Divider, 1/2” Ports Proportional Flow Divider, 1/2” Ports Proportional Flow Divider, 3/4” Ports Selector Valve, 1/2” Ports Selector Valve, 3/4” Ports Single Selector 1/2” Work Ports Single Selector #8 Work Ports Adjustable Relief (Differential Poppet ), #10 Ports Adjustable Relief (Differential Poppet ), 1/2” Ports Adjustable Relief (Differential Poppet ), 1/2” Ports Prince Manufacturing Corporation 612 N. Derby Lane P.O. Box 7000 North Sioux City, SD 57049-7000 G`gf]Û¤¤~ÛÝÛ=8OÛ¤¤~ LICÛooohjaf[]`q\[geÛÝÛ<¤eYadÛhjaf[]³hjaf[]`q\[ge CATV 75-07-13-02 35,1&(0$18)$&785,1*&25325$7,2132%2;1257+6,28;&,7<6287+'$.27$ 85/ZZZSULQFHK\GFRP(0$,/SULQFH#SULQFHK\GFRP 2(0&86720(56(59,&()$;',675,%8725&86720(56(59,&(3+21()$; V75 VALVES Accessory Valves