TECHNICAL SUMMARY SHEET
HAC240 – Series
Doc ref hac-tss2(240V)
Issue
2
Date
Jan 2005
240V SINGLE PHASE 50/60Hz AC LOAD BANKS
HAC240 Series load banks for single phase gen-set and UPS testing
Type ref
HAC240-5
HAC240-8
HAC240-11
HAC240-14
Max Volts
1 ph 50/60hz
240V
240V
240V
240V
Max
watts
5451W
8251W
11050W
13851W
Max
amps
22A
33A
45A
57A
Case size (mm)
length
width
height
710mm 330mm 425mm
710mm 330mm 425mm
710mm 330mm 425mm
710mm 330mm 425mm
approx.
weight
19 kgs
21 kgs
25 kgs
27 kgs
Notes :
1. The load bank cooling fan is powered from the gen-set or
UPS under test and does not require an external auxiliary
supply.
2. The load bank can operate at 200V, 220V & 230V with
proportional reduction in load current.
3. HAC load banks are for AC operation only
4. The load banks include an earth leakage isolation circuit
breaker, load isolation contactors and fan failure protection.
Hillstone Products Ltd
Unit D2 Greenbrook Business Park
Greenbrook Street
Bury
Lancashire England BL9 6LZ
Tel. +44 (0) 161 763 3100
Fax. +44 (0) 161 763 3158
e-mail sales@hillstone.co.uk
web www.hillstone.co.uk
TECHNICAL SUMMARY SHEET
HAC415 – Series
Doc ref hac-tss5(415V)
Issue
5
Date
Jan 2005
415V THREE PHASE 50/60Hz AC LOAD BANKS
HAC415 Series load banks for three phase gen-set and UPS testing
Type ref
HAC415-10
HAC415-20
HAC415-30
HAC415-40
HAC415-50
HAC415-60
HAC415-70
HAC415-80
HAC415-90
HAC415-100
Max Volts
3ph 50/60hz
415V
415V
415V
415V
415V
415V
415V
415V
415V
415V
Max
watts
10KW
20KW
30KW
40KW
50KW
60KW
70KW
80KW
90KW
100KW
Case size (mm)
length
width
height
900mm 450mm 600mm
900mm 450mm 650mm
900mm 450mm 700mm
900mm 450mm 750mm
1000mm 450mm 1000mm
1000mm 450mm 1000mm
1000mm 450mm 1200mm
1000mm 450mm 1200mm
1000mm 450mm 1500mm
1000mm 450mm 1500mm
approx.
weight
35 kgs
42 kgs
48 kgs
55 kgs
65 kgs
70 kgs
85 kgs
95 kgs
110 kgs
125 kgs
Notes :
1. The load bank cooling fan is powered from the gen-set or
UPS under test and does not require an external auxiliary
supply. Separate aux supply available as optional extra.
2. The load bank can operate at 380V & 400V with
proportional reduction in load current.
3. HAC load banks are for AC operation only
4. The load banks include load isolation contactors and fan
failure protection.