LIGHTING FIXTURES K L M METRO BATH WALL SCONCE ISLAND PENDANT (PENTHOUSE) - HENRY PENDANT LINEAR LED, ACCENT LIGHT TUCKED INTO VERTICAL COVE N (PENTHOUSE) - ELECTRA WALL MOUNTED, SINGLE ARM SCONCE WITH GLASS SHADE 2 - COMMON A 3.5" SQUARE RECESSED TRIMLESS DOWNLIGHT, REGRESSED SOLITE LENS, WHITE BEVEL FINISH, 50 DEGREE BEAM B LINEAR LED, REGRESSED COVE ILLUMINATING ETCHED C LINEAR REGRESSED WALL FIXTURE, WHITE FINISH, UP AND DOWN LIGHT ENGINE WITH ALUMINUM CHANNEL D LINEAR LED COVE G WALL MOUNTED INDIRECT CORRIDOR FIXTURES, WHITE O P1 P2 P3 4" LINEAR LED, RECESSED 35" STATEMENT PENDANT, POLISHED CHROME & GLASS 26" STATEMENT PENDANT, POLISHED NICKEL 34" STATEMENT PENDANT, WHITE CORDS P4 24" PENDANT, SATIN NICKEL R 4" LINEAR LED PENDANT, DIRECT LIGHT T 4' DIAMETER ROUND PENDANT, DIRECT LIGHT Z TRIMLESS RECESSED 2-LIGHT ADJUSTABLE, WHITE HOUSING 3 - EXTERIOR E 300 LINE ENCLOSED DOWNLIGHT F BEVEL, 6" SQUARE COMPACT FLUORESCENT DOWNLIGHT WITH TRIM SA 302 UP/DOWN CYLINDER SB CUSTOM BENT LED, BACKLIGHTING 3 - EXTERIOR ALTERNATE F 6" ROUND CYLINDER SURFACE MOUNT DOWNLIGHT, MEDIUM FLOOD, REGRESSED LENS, WHITE TRIM & HOUSING SA LINEAR REGRESSED WALL FIXTURE, WHITE FINISH, UP AND DOWN LIGHT ENGINE WITH ALUMINUM CHANNEL 4 - SITE SC FOUNTAIN LIGHT KIT, SPILLS INTO POOL REFLECTED CEILING PLAN - LEGEND & DETAILS UNILUME TECH LIGHTING TECH LIGHTING WATERWORKS LED INSPIRATIONS 700UCRD-13-9-30-B-LED 700-TD-SARGP-C-W-CF LED 3000K COMPACT FLUORESCENT 120V COMPACT FLUORESCENT KITCHEN KITCHEN X1 INCANDESCENT A19 LED 3000K 4.32 WATTS PER 1FT E26 T10 BULB 3. 4. 5. 6. 7. 8. 9. 10. BATHROOM PENTHOUSE, KITCHEN PENTHOUSE, ALONG SHOWER WALL, BATHROOM. WET LOCATION (NOT SUBMERSIBLE), CONTRACTOR TO VERIFY RUN LENGTHS, DRIVER & CABLES REQUIRED PENTHOUSE, BATHROOM 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. USAi ECOSENSE KREON 3311-B1-SOLITE-10-LSLD4-9024-C2-35KS-50-N C-VOLT 3311-B1-SOLITE-10-LSLD4-9024-C2-35KS-50-N C-VOLT KU915401 ENGINE X 2 UP/DOWN; KU715003 CHANNEL; LAMP: MR16-40-B01-12-930-10-2 LED 3500K 24 WATTS LEASING OFFICE, GYP CEILINGS, UNIT RESTROOMS LED 3500K 10 WATTS PER 1FT GLASS IN LEASING OFFICE, CONTRACTOR TO VERIFY RUN LENGTHS (1FT OR 4FT) AND CABLES REQUIRED 21. 22. 23. 24. 25. 26. RETROFIT: LED 3000K SORAA LEASING OFFICE, VERTICAL INSTALLATION IN WALLS, CONTRACTOR TO VERIFY CHANNEL LENGTH REQUIRED MR16 GU5.3 10SP 50W PER ENGINE, 100W FOR UP/DOWN ECOSENSE LCIS-LENGTH-35-VOLT-120 / LED 3500K 5 WATTS PER 1FT AROUND STATEMENT PENDANTS & UNDER CANOPY DRIVE, CONTRACTOR TO VERIFY RUN LENGTHS (1FT OR INT3P-A-LDR-120-10 4FT) AND CABLES REQUIRED KREON KR915041 / KR15009 FLUORESCENT 3500K (1) 55 PROBABLY USE THE TYPE A DOWNLIGHTS IN SOFFIT ABOVE UNIT DOORWAYS WATTS 2G11 FINELITE HP-4-R-LENGTH-SO-3500K-VOLT-SC-MOUNT LED 3500K 18 WATTS PER 4FT BUSINESS CENTER, SPECIFY MOUNTING, CONTRACTOR TO VERIFY RUN LENGTHS EUROFASE 25636-017 HALOGEN (12) 20 WATT G4 LEASING OFFICE EUROFASE 25623-017 HALOGEN (5) 60 WATT G9 LEASING OFFICE EUROFASE 22973-030 HALOGEN (12) 40 WATT LEASING OFFICE B10/E12 EUROFASE 20445-027 LAMP: MR16-50-B03-12-930-36 RETROFIT: LED 3000K SORAA BUSINESS CENTER IN COMPUTER NICHES MR16 GU10 (1) 50 WATTS FINELITE HP-4-D-LENGTH-SO-3500K-VOLT-FA-SC-MOU LED 3500K 18 WATTS PER 4FT FITNESS CENTER CONTRACTOR TO VERIFY RUN LENGTHS NT HE WILLIAMS RNDP-4-532U-FFA-PMLENGTH-EB3/2-UNV FLUORESCENT 3500K (5) 32 FITNESS CENTER, CONTRACTOR VERIFY SUSPENSION CABLE DROP WATT U T8 LF MF12DN-S-040PR30X-YD-NA-VOLT-WW, RETROFIT: LED 3000K LEASING OFFICE / WALL WASHER ILLUMINATION LAMP: QP30L30NFCWE WHITE LUMENOVA PAR30 (2) 40W WATTS PHILIPS USAi 300-D-W-LL-32TRF-120-NP 4400-10-F-BL125-A COMPACT FLUORESCENT COMPACT FLUORESCENT PHILIPS iLIGHT 302-E-W-32TRF-LL-120V-NP PLEXINEON SIGNAGE WHITE COMPACT FLUORESCENT LED 3500K 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. EXTERIOR BALCONIES MOUNT STRAIGHT TO RECESSED J-BOX IN UNITS; CAN ALSO USE THESE IN CORRIDORS TO ADD MORE LIGHT, UNDER CANOPY DRIVE EXTERIOR FAÇADE ALONG STREET, VERTICAL INSTALLATION IN WALLS SIGNAGE, PROVIDE DRAWINGS TO iLIGHT ALL ACOUSTICAL AND FIRE-RATED WALL TO EXTEND TO UNDERSIDE OF DECK U.N.O. REFLECTED CEILING PLAN NOTES, LEGEND & KEY NOTES, AND DETAILS ON THIS SHEET ARE TO BE USED ON A03 SERIES SHEETS. PLEASE NOTE, NOT ALL GENERAL REFLECTED CEILING PLAN OR SPECIFIC KEY NOTES WILL BE USED ON EACH REFLECTED CEILING PLAN SHEET IN THE A03 SHEET SERIES. ANY KEY NOT NOT USED ON THE SHEET SHOULD BE DISREGARDED FOR THAT FLOOR. REFERENCE G00-10 FOR STANDARDS, CODE INFORMATION AND ADDITIONAL LEGENDS. ELECTRICAL CONTRACTOR TO PROVIDE TEMPORARY LIGHTING SERVICE FOR TRADES. ALL PARTITIONS SCHEDULED TO STOP AT UNDERSIDE OF FINISH CEILING TO HAVE BRACE HEAD TRACK BACK TO STRUCTURE @ 4'-0" O.C. (MAX). ALL EXISTING AND NEW PARTITIONS AT RESTROOMS TO EXTEND TO DECK AND BE INSULATED, U.N.O. C O R G A N CONTRACTOR TO COORDINATE WORK WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY ALIGNED WITH EACH OTHER AND WITH THE RECESSED LIGHTING FIXTURES. CEILING GRID TO BE CENTERED IN ROOM, U.N.O. INSTALLATION OF ALL EQUIPMENT IN THE PLENUM SHALL BE COORDINATED WITH TRADES TO MINIMIZE CONFLICTS. CEILING DIFFUSERS TO BE LOCATED TO MAINTAIN NEW FIXTURE PATTERNS. PRIOR TO CLOSING UP CEILING PLENUM SYSTEMS, (HVAC, PLUMBING AND ELECTRICAL) SHALL BE INSPECTED AND TESTED BY CONTRACTOR'S ENGINEERS AND BY AUTHORITIES HAVING JURISDICTION TO ENSURE PROPER INSTALLATION AND FUNCTION. PROVIDE AND INSTALL FIRE PROOFING AS REQUIRED, PER LOCAL CODES, IN OPEN PLENUM AREAS. REF. SPEC. FOR FIREPROOFING MATERIALS. HVAC CONTRACTOR TO INSPECT SYSTEMS FOR PROPER OPERATIONS AT COMPLETION OF THE JOB. BALANCING OF HVAC SYSTEM SHALL BE PERFORMED BY A QUALIFIED ENGINEER. SUBMIT WRITTEN REPORT TO BUILDING MANAGEMENT UPON COMPLETION. CONTRACTOR TO PROVIDE LIGHTING FIXTURE WORK AS SHOWN ON DRAWINGS AND NOTES. CONTACT ARCHITECT ON LIGHTING CHANGES OR CONFLICTS IN DIMENSIONS FOR LIGHTING LOCATIONS. ALL LIGHT FIXTURES LOCATED IN CEILING TILE SHOULD BE CENTERED IN THE TILE, U.N.O. WHERE SHOWN, DIMENSIONS ARE TO CENTER LINE OF LIGHT FIXTURE, U.N.O. REFERENCE MEP DOCUMENTS FOR ADDITIONAL INFORMATION AND THE LIGHT FIXTURE SCHEDULE. CORGAN 401 N. Houston Street Dallas, TX 75202 T: 214.748.2000 F: 214.653.8281 ISSUES 1 05/12/2014 SCHEMATIC DESIGN PACKAGE 2 05/20/2014 ADDENDUM 1 3 06/04/2014 SUPER STRUCTURE PACKAGE 4 06/23/2014 DESIGN DEVELOPMENT PACKAGE 5 07/18/2014 ADDENDUM 2 6 08/01/2014 MEPT PROGRESS SET 7 8/29/2014 90% COORDINATION PACKAGE 8 SUBMIT CITY APPROVED FIRE PROTECTION PLAN FOR SPRINKLER LOCATION AND FIRE SAFETY 9 REQUIREMENTS TO BUILDING MANAGER FOR APPROVAL. 10 FIRE PROTECTION CONTRACTOR TO VERIFY REQUIREMENTS AND QUANTITY OF FIRE PROTECTION DEVICES, INCLUDING SMOKE DETECTORS, FIRE ALARMS, SPEAKERS, STROBES, ETC. INCLUDE COSTS TO TIE SUCH DEVICES INTO BUILDING PANEL. LIFE SAFETY INSTALLATIONS TO MEET ADAAG AND TAS REQUIREMENTS. ALL NEW SPRINKLER HEADS AND ESCUTCHEONS TO MATCH EXISTING SPRINKLER HEADS AND ESCUTCHEONS. COORDINATE SPEC WITH OWNER. SPRINKLER HEADS TO BE CENTERED IN TILE, U.N.O. NEW LOCATIONS ARE TO BE BASED ON PREVAILING FIRE AND BUILDING CODES. PROVIDE ALL LIFE SAFETY INSTALLATIONS PER TAS/ADAAG REQUIREMENTS. PROVIDE AND INSTALL EXIT SIGNS AND EMERGENCY LIGHTING. INCLUDE COSTS TO TIE SUCH DEVICES INTO BUILDING PANEL. VERIFY QUANTITY AND LOCATIONS REQUIRED BY CODE. LIFE SAFETY INSTALLATIONS TO MEET ADAAG AND STATE ACCESSIBILITY REQUIREMENTS. (TAS IN THE STATE OF TEXAS). FINAL EXIT SIGN LOCATIONS TO BE COORDINATED WITH ARCHITECT PRIOR TO INSTALLATION. ALL GYP. BD. CEILINGS TO BE PAINTED PNT- U.N.O. CONTRACTOR TO COORDINATE LOCATIONS OF ALL ACCESS PANELS WITH ARCHITECT PRIOR TO INSTALLATION. ALL PERIMETER SLOT DIFFUSER BLANK OFF PLATES SHALL BE SOLID BLANK OFF PLATES. R.C.P.'S WILL TYPICALLY INDICATE LOCATIONS, DIMENSIONS AND HEIGHTS A.F.F. OR FURRDOWNS, VARYING CEILING MATERIALS AND THEIR LOCATIONS, HEIGHTS OF WALLS A.F.F. (FULL HEIGHT AND PARTIAL HEIGHT), REQUIRED FIRE-RATINGS OF WALLS, AND FINAL LOCATIONS OF CEILING MOUNTED FIXTURES/ DEVICES . LIGHT FIXTURES IN MECHANICAL AND EQUIPMENT ROOMS ARE SHOWN FOR QUANTITY ONLY. CONTRACTOR IS TO COORDINATE FIXTURE PLACEMENT WITH ALL MEP ITEMS AND SET FINAL FIXTURE LOCATIONS AS REQUIRED TO EVENLY AND FULLY LIGHT ACCESSIBLE AREAS OF THE ROOM WITH THE QUANTITY OF FIXTURES SHOWN. PROVIDE THREE WAY LIGHT SWITCHES FOR CORRIDOR AND OPEN AREA LIGHT FIXTURES, U.N.O., REF. M.E.P. THE ROOM FINISH SCHEDULE TYPICALLY INDICATES CEILING MATERIALS AND FINISHES. MATERIALS OR FINISHES THAT VARY WITHIN A ROOM WILL BE INDICATED ON THE R.C.P. PROVIDE ADDITIONAL SUPPORT FOR TRACK LIGHTING AS REQUIRED. DO NOT INSTALL CEILING GRID UNTIL WORK ABOVE CEILING IS COORDINATED AND INSTALLED WITHIN AVAILABLE PLENUM SPACE. LIGHT FIXTURES IN MECHANICAL AND EQUIPMENT ROOMS ARE SHOWN FOR QUANTITY ONLY. CONTRACTOR IS TO COORDINATE FIXTURE PLACEMENT WITH ALL MEP ITEMS AND SET FINAL FIXTURE LOCATIONS AS REQUIRED TO EVENLY AND FULLY LIGHT ACCESSIBLE AREAS OF THE ROOM WITH THE QUANTITY OF FIXTURES SHOWN. GYP. CEILINGS AND BULKHEADS TO BE PAINTED PER DETAIL SECTIONS IF AVAILABLE AND/OR ELEVATIONS. ACCENT PAINT ON GYP. BOARD BULKHEADS TO BE ON BOTTOM AND SIDES OF BULKHEAD. COORDINATE MEP / ETC. DRAWINGS FOR ALL FIXTURES/ DEVICES MOUNTED IN, ABOVE, OR HUNG FROM THE CEILING. FINAL FIXTURE/DEVICE LOCATIONS ARE DETERMINED BY THE ARCHITECTURAL R.C.P. WHERE CONDITIONS DIFFER SIGNIFICANTLY BETWEEN THE PLANS, REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. WHERE FIXTURES/ DEVICES SHOWN OR SPECIFIED ON DRAWINGS OTHER THAN THE ARCHITECTURAL R.C.P.'S ARE VISIBLE AT THE CEILING PLANE, COORDINATE LOCATIONS WITH THE ARCHITECT. REVISIONS This Document was produced by or under the direct supervision of Registered Architect Matthew G. Mooney This document is incomplete and may not be used for regulatory approval, permit or construction. Date of issue: 06/23/2014 RCP KEY NOTES R01 KIRLIN KREON iLIGHT STAIRWELL LIGHT SLF 700BCMET-Y-C-CF 18-47520-83414 / CHROME FINISH INSPIRE-W-3000-24VDC-LENGTH DR-WATT-24VDC-NONDIM STRIPCHAN5FT-OUTDOOR WATERWORKS EELT01 / CHROME FINISH LINEAR LED LIGHT W A03-00 KITCHEN / BEDROOM / BATH / CLOSET SH 5 - GARAGE ALTERNATE SK LINEAR FIXTURE; SURFACE MOUNT 6 - BACK OF HOUSE V 4' STRIP PENDANT, WIRE GUARD, Y-HANGERS 8/29/2014 2:45:40 PM COMPACT FLUORESCENT SUBMERSION LED SPOT LIGHT, ADJUSTABLE SUBMERSION LED SPOT LIGHT, RECESSED SMALL LINEAR LED DOWNLIGHT 4 - SITE ALTERNATE SJ SMALL SQUARE CYLINDER UP/DOWN 5 - GARAGE SK ARCHITECTURAL ROUND GARAGE LIGHT LOCATION 4400-10-F-BL125-A SD SF SG MINISLOT SQUARE WALL LAMP USAi ATLANTIC WATER GARDENS SIMES SIMES SIMES SJ CATALOG NUMBER 1. 2. SISTEMALUX LSR-06201-35K-WHITE KU915901 ENGINE X 2 UP/DOWN KU715903 CHANNEL LAMP: MR16-40-B01-12-930-10-2 COLORFALLS T-24-W35-S-LENGTH-SC-00 LED 3500K 20 WATTS MOUNT STRAIGHT TO RECESSED J-BOX IN UNITS; CAN ALSO USE THESE IN CORRIDORS TO ADD MORE LIGHT, UNDER CANOPY DRIVE RETROFIT: LED 3000K SORAA EXTERIOR FAÇADE ALONG STREET, VERTICAL INSTALLATION IN WALLS, WET LOCATION. CONTRACTOR TO MR16 GU5.3 10SP 50W PER VERIFY CHANNEL LENGTH REQUIRED ENGINE, 100W FOR UP/DOWN LED 3500K POOL FOUNTAIN, SPECIFY LENGTH & COLOR DESIRED, ACCESSORIES REQUIRED R02 R03 R04 R05 R06 1699 HERMANN DRIVE, HOUSTON, TEXAS 77004 TYPE DESCRIPTION 1 - UNIT H BEVEL, 6" SQUARE COMPACT FLUORESCENT DOWNLIGHT WITH TRIM I LED SLIMLINE J ISLAND PENDANT - SARA GRANDE PENDANT MANUFACTUR ER GENERAL RCP NOTES R07 R08 S.3696.19 / S.3672 / S.3670 / S.366? S.3627.19 / S.366? / S.3670 S.7200W / S.34?? S.3842-UNV LED 6000K 34 WATTS LED 6000K 34 WATTS LED 3000K 12.5 WATTS IN FOUNTAIN CONTRACTOR TO VERIFY JUNTION BOX REQUIRED IN POOL CONTRACTOR TO VERIFY JUNTION BOX REQUIRED TUCKED ALONG LIP EDGE OF SHORT WALLS, FIREPIT, BARBEQUE & POOL AREAS CONTRACTOR TO VERIFY DRIVER & WATTAGE REQUIRED LED 3000K 2.59 WATTS PER TUCKED UNDER LOW WALL LEDGE, OR UNDERNEATH SEATING AREAS, FIREPIT, BARBEQUE & POOL AREA , 1FT CONTRACTOR TO VERIFY RUN LENGTHS & DRIVERS STAIGHT OR BENDABLE IN FIELD 35W FOR 2 LAMPS T4.5 METAL SURFACE MOUNT TO BARBEQUE AREA COLUMNS HALIDE, G8.5 BASE R09 RCP PARTITION SYMBOLS UNRATED PARTITION ASSEMBLY TO EXTEND TO UNDERSIDE OF CEILING OF CEILING GRID A.F.F. ACOUSTICALLY ATTENUATED PARTITION TO UNDERSIDE OF DECK A.F.F. SIMES S.3852W LED 3200K 32 WATTS SURFACE MOUNT TO BARBEQUE AREA COLUMNS 30 MIN. SMOKE SEAL PARTITION TO UNDERSIDE OF DECK A.F.F. WILLIAMS OUTDOOR LIGHTING ARD-PSMH-150-MED-OPTIONS-120 COMPACT FLUORESCENTS GARAGE 1 HOUR PARTITION ASSEMBLY TO UNDERSIDE OF DECK A.F.F. 2 HOUR PARTITION ASSEMBLY TO UNDERSIDE OF DECK A.F.F. UNRATED PARTITION ASSEMBLY TO EXTEND 6" ABOVE CEILING GRID A.F.F. DAYBRITE DWAE-42L-835-4-UNV / TBK LED 3500K 40 WATTS GARAGE HE WILLIAMS GLN-4-232-UP-VBY-WG11-EB2-UNV FLUORESCENT (2) 32W T8 3500K FLUORESECENT (2) 24-WATT T5HO BACK OF HOUSE WILLIAMS SLF-4-2-54T5H-HIA-OPTIONS-EB2-UNV FLUORESCENT LIGHTING EELP UR-EDGR-1-R-C-A-EM RECESSED EDGE LIT, SINGLE SIDED, RED LETTERS, CLEAR, EM NiCAD BATTERY, ALUMINUM TRIM X2 RECESSED EDGE LIT, DOUBLE SIDED, RED LETTERS, CLEAR WITH EELP SILVER INSERT, EM NiCAD BATTERY, ALUMINUM TRIM 6 - BACK OF HOUSE ALTERNATE W 2' WALL MOUNTED, 50% BI-LEVEL LAMAR LIGHTING LED STAIRWELL FIXTURE REFLECTED CEILING PLAN LEGEND 2X2 LAY-IN CEILING LINEAR SUSPENDED GYP. BD. CEILING LINEAR COVE LIGHT SCONCE FIXTURE 2X4 LAY-IN EXIT 1X4 HUNG PARABOLIC STRIP 2X2 SUSPENDED SUPPLY AIR DIFFUSER 2X2 LAY-IN UR-EDGR-2-R-S-A-EM LED EXIT RETURN AIR DIFFUSER SQUARE RECESSED DOWN LIGHT EMERGENCY EXIT FIXTURE RECESSED LED DLIRL-24-L-RA-W-35-W-2C-HBX LED 3500K 15W PER 2FT STAIRWELL FIXTURE SPECIFY OCCUPANCY SENSOR SUSPENDED DOWN LIGHT DECORATIVE PENDANT 1' - 0" C FINISHED CEILING HEIGHT A.F.F. PG NOTE: ALL CEILING HEIGHTS ARE TO BE 9'-0" A.F.F. U.N.O. B A REFLECTED CEILING PLAN LEGEND & DETAILS JOB DATE SHEET 13157.0300 06/23/2014 A03-00