A03-00 - RedTeam Software

advertisement
LIGHTING FIXTURES
K
L
M
METRO BATH WALL SCONCE
ISLAND PENDANT (PENTHOUSE) - HENRY PENDANT
LINEAR LED, ACCENT LIGHT TUCKED INTO VERTICAL COVE
N
(PENTHOUSE) - ELECTRA WALL MOUNTED, SINGLE ARM SCONCE
WITH GLASS SHADE
2 - COMMON
A
3.5" SQUARE RECESSED TRIMLESS DOWNLIGHT, REGRESSED
SOLITE LENS, WHITE BEVEL FINISH, 50 DEGREE BEAM
B
LINEAR LED, REGRESSED COVE ILLUMINATING ETCHED
C
LINEAR REGRESSED WALL FIXTURE, WHITE FINISH, UP AND
DOWN LIGHT ENGINE WITH ALUMINUM CHANNEL
D
LINEAR LED COVE
G
WALL MOUNTED INDIRECT CORRIDOR FIXTURES, WHITE
O
P1
P2
P3
4" LINEAR LED, RECESSED
35" STATEMENT PENDANT, POLISHED CHROME & GLASS
26" STATEMENT PENDANT, POLISHED NICKEL
34" STATEMENT PENDANT, WHITE CORDS
P4
24" PENDANT, SATIN NICKEL
R
4" LINEAR LED PENDANT, DIRECT LIGHT
T
4' DIAMETER ROUND PENDANT, DIRECT LIGHT
Z
TRIMLESS RECESSED 2-LIGHT ADJUSTABLE, WHITE HOUSING
3 - EXTERIOR
E
300 LINE ENCLOSED DOWNLIGHT
F
BEVEL, 6" SQUARE COMPACT FLUORESCENT DOWNLIGHT WITH
TRIM
SA
302 UP/DOWN CYLINDER
SB
CUSTOM BENT LED, BACKLIGHTING
3 - EXTERIOR ALTERNATE
F
6" ROUND CYLINDER SURFACE MOUNT DOWNLIGHT, MEDIUM
FLOOD, REGRESSED LENS, WHITE TRIM & HOUSING
SA
LINEAR REGRESSED WALL FIXTURE, WHITE FINISH, UP AND
DOWN LIGHT ENGINE WITH ALUMINUM CHANNEL
4 - SITE
SC
FOUNTAIN LIGHT KIT, SPILLS INTO POOL
REFLECTED CEILING PLAN - LEGEND & DETAILS
UNILUME
TECH
LIGHTING
TECH
LIGHTING
WATERWORKS
LED
INSPIRATIONS
700UCRD-13-9-30-B-LED
700-TD-SARGP-C-W-CF
LED 3000K
COMPACT FLUORESCENT
120V
COMPACT FLUORESCENT
KITCHEN
KITCHEN
X1
INCANDESCENT A19
LED 3000K 4.32 WATTS PER
1FT
E26 T10 BULB
3.
4.
5.
6.
7.
8.
9.
10.
BATHROOM
PENTHOUSE, KITCHEN
PENTHOUSE, ALONG SHOWER WALL, BATHROOM. WET LOCATION (NOT SUBMERSIBLE), CONTRACTOR TO VERIFY
RUN LENGTHS, DRIVER & CABLES REQUIRED
PENTHOUSE, BATHROOM
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
USAi
ECOSENSE
KREON
3311-B1-SOLITE-10-LSLD4-9024-C2-35KS-50-N
C-VOLT
3311-B1-SOLITE-10-LSLD4-9024-C2-35KS-50-N
C-VOLT
KU915401 ENGINE X 2 UP/DOWN; KU715003
CHANNEL; LAMP: MR16-40-B01-12-930-10-2
LED 3500K 24 WATTS
LEASING OFFICE, GYP CEILINGS, UNIT RESTROOMS
LED 3500K 10 WATTS PER 1FT GLASS IN LEASING OFFICE, CONTRACTOR TO VERIFY RUN LENGTHS (1FT OR 4FT) AND CABLES REQUIRED
21.
22.
23.
24.
25.
26.
RETROFIT: LED 3000K SORAA LEASING OFFICE, VERTICAL INSTALLATION IN WALLS, CONTRACTOR TO VERIFY CHANNEL LENGTH REQUIRED
MR16 GU5.3 10SP 50W PER
ENGINE, 100W FOR UP/DOWN
ECOSENSE
LCIS-LENGTH-35-VOLT-120 /
LED 3500K 5 WATTS PER 1FT AROUND STATEMENT PENDANTS & UNDER CANOPY DRIVE, CONTRACTOR TO VERIFY RUN LENGTHS (1FT OR
INT3P-A-LDR-120-10
4FT) AND CABLES REQUIRED
KREON
KR915041 / KR15009
FLUORESCENT 3500K (1) 55
PROBABLY USE THE TYPE A DOWNLIGHTS IN SOFFIT ABOVE UNIT DOORWAYS
WATTS 2G11
FINELITE
HP-4-R-LENGTH-SO-3500K-VOLT-SC-MOUNT LED 3500K 18 WATTS PER 4FT BUSINESS CENTER, SPECIFY MOUNTING, CONTRACTOR TO VERIFY RUN LENGTHS
EUROFASE
25636-017
HALOGEN (12) 20 WATT G4
LEASING OFFICE
EUROFASE
25623-017
HALOGEN (5) 60 WATT G9
LEASING OFFICE
EUROFASE
22973-030
HALOGEN (12) 40 WATT
LEASING OFFICE
B10/E12
EUROFASE
20445-027 LAMP: MR16-50-B03-12-930-36
RETROFIT: LED 3000K SORAA BUSINESS CENTER IN COMPUTER NICHES
MR16 GU10 (1) 50 WATTS
FINELITE
HP-4-D-LENGTH-SO-3500K-VOLT-FA-SC-MOU LED 3500K 18 WATTS PER 4FT FITNESS CENTER CONTRACTOR TO VERIFY RUN LENGTHS
NT
HE WILLIAMS RNDP-4-532U-FFA-PMLENGTH-EB3/2-UNV
FLUORESCENT 3500K (5) 32
FITNESS CENTER, CONTRACTOR VERIFY SUSPENSION CABLE DROP
WATT U T8
LF
MF12DN-S-040PR30X-YD-NA-VOLT-WW,
RETROFIT: LED 3000K
LEASING OFFICE / WALL WASHER
ILLUMINATION LAMP: QP30L30NFCWE WHITE
LUMENOVA PAR30 (2) 40W
WATTS
PHILIPS
USAi
300-D-W-LL-32TRF-120-NP
4400-10-F-BL125-A
COMPACT FLUORESCENT
COMPACT FLUORESCENT
PHILIPS
iLIGHT
302-E-W-32TRF-LL-120V-NP
PLEXINEON SIGNAGE WHITE
COMPACT FLUORESCENT
LED 3500K
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
EXTERIOR BALCONIES
MOUNT STRAIGHT TO RECESSED J-BOX IN UNITS; CAN ALSO USE THESE IN CORRIDORS TO ADD MORE LIGHT,
UNDER CANOPY DRIVE
EXTERIOR FAÇADE ALONG STREET, VERTICAL INSTALLATION IN WALLS
SIGNAGE, PROVIDE DRAWINGS TO iLIGHT
ALL ACOUSTICAL AND FIRE-RATED WALL TO EXTEND TO UNDERSIDE OF DECK U.N.O.
REFLECTED CEILING PLAN NOTES, LEGEND & KEY NOTES, AND DETAILS ON THIS SHEET ARE TO BE
USED ON A03 SERIES SHEETS.
PLEASE NOTE, NOT ALL GENERAL REFLECTED CEILING PLAN OR SPECIFIC KEY NOTES WILL BE USED
ON EACH REFLECTED CEILING PLAN SHEET IN THE A03 SHEET SERIES. ANY KEY NOT NOT USED ON
THE SHEET SHOULD BE DISREGARDED FOR THAT FLOOR.
REFERENCE G00-10 FOR STANDARDS, CODE INFORMATION AND ADDITIONAL LEGENDS.
ELECTRICAL CONTRACTOR TO PROVIDE TEMPORARY LIGHTING SERVICE FOR TRADES.
ALL PARTITIONS SCHEDULED TO STOP AT UNDERSIDE OF FINISH CEILING TO HAVE BRACE HEAD
TRACK BACK TO STRUCTURE @ 4'-0" O.C. (MAX).
ALL EXISTING AND NEW PARTITIONS AT RESTROOMS TO EXTEND TO DECK AND BE INSULATED, U.N.O.
C O R G A N
CONTRACTOR TO COORDINATE WORK WITH MANUFACTURER'S RECOMMENDATIONS FOR
INSTALLATION.
JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY ALIGNED WITH EACH OTHER
AND WITH THE RECESSED LIGHTING FIXTURES.
CEILING GRID TO BE CENTERED IN ROOM, U.N.O.
INSTALLATION OF ALL EQUIPMENT IN THE PLENUM SHALL BE COORDINATED WITH TRADES TO
MINIMIZE CONFLICTS. CEILING DIFFUSERS TO BE LOCATED TO MAINTAIN NEW FIXTURE PATTERNS.
PRIOR TO CLOSING UP CEILING PLENUM SYSTEMS, (HVAC, PLUMBING AND ELECTRICAL) SHALL BE
INSPECTED AND TESTED BY CONTRACTOR'S ENGINEERS AND BY AUTHORITIES HAVING JURISDICTION
TO ENSURE PROPER INSTALLATION AND FUNCTION.
PROVIDE AND INSTALL FIRE PROOFING AS REQUIRED, PER LOCAL CODES, IN OPEN PLENUM AREAS.
REF. SPEC. FOR FIREPROOFING MATERIALS.
HVAC CONTRACTOR TO INSPECT SYSTEMS FOR PROPER OPERATIONS AT COMPLETION OF THE JOB.
BALANCING OF HVAC SYSTEM SHALL BE PERFORMED BY A QUALIFIED ENGINEER. SUBMIT WRITTEN
REPORT TO BUILDING MANAGEMENT UPON COMPLETION.
CONTRACTOR TO PROVIDE LIGHTING FIXTURE WORK AS SHOWN ON DRAWINGS AND NOTES.
CONTACT ARCHITECT ON LIGHTING CHANGES OR CONFLICTS IN DIMENSIONS FOR LIGHTING
LOCATIONS.
ALL LIGHT FIXTURES LOCATED IN CEILING TILE SHOULD BE CENTERED IN THE TILE, U.N.O.
WHERE SHOWN, DIMENSIONS ARE TO CENTER LINE OF LIGHT FIXTURE, U.N.O.
REFERENCE MEP DOCUMENTS FOR ADDITIONAL INFORMATION AND THE LIGHT FIXTURE SCHEDULE.
CORGAN
401 N. Houston Street
Dallas, TX 75202
T: 214.748.2000 F: 214.653.8281
ISSUES
1
05/12/2014
SCHEMATIC DESIGN PACKAGE
2
05/20/2014
ADDENDUM 1
3
06/04/2014
SUPER STRUCTURE PACKAGE
4
06/23/2014
DESIGN DEVELOPMENT PACKAGE
5
07/18/2014
ADDENDUM 2
6
08/01/2014
MEPT PROGRESS SET
7
8/29/2014
90% COORDINATION PACKAGE
8
SUBMIT CITY APPROVED FIRE PROTECTION PLAN FOR SPRINKLER LOCATION AND FIRE SAFETY
9
REQUIREMENTS TO BUILDING MANAGER FOR APPROVAL.
10
FIRE PROTECTION CONTRACTOR TO VERIFY REQUIREMENTS AND QUANTITY OF FIRE PROTECTION
DEVICES, INCLUDING SMOKE DETECTORS, FIRE ALARMS, SPEAKERS, STROBES, ETC. INCLUDE
COSTS TO TIE SUCH DEVICES INTO BUILDING PANEL. LIFE SAFETY INSTALLATIONS TO MEET ADAAG
AND TAS REQUIREMENTS.
ALL NEW SPRINKLER HEADS AND ESCUTCHEONS TO MATCH EXISTING SPRINKLER HEADS AND
ESCUTCHEONS. COORDINATE SPEC WITH OWNER.
SPRINKLER HEADS TO BE CENTERED IN TILE, U.N.O. NEW LOCATIONS ARE TO BE BASED ON
PREVAILING FIRE AND BUILDING CODES.
PROVIDE ALL LIFE SAFETY INSTALLATIONS PER TAS/ADAAG REQUIREMENTS.
PROVIDE AND INSTALL EXIT SIGNS AND EMERGENCY LIGHTING. INCLUDE COSTS TO TIE SUCH
DEVICES INTO BUILDING PANEL. VERIFY QUANTITY AND LOCATIONS REQUIRED BY CODE. LIFE
SAFETY INSTALLATIONS TO MEET ADAAG AND STATE ACCESSIBILITY REQUIREMENTS. (TAS IN THE
STATE OF TEXAS). FINAL EXIT SIGN LOCATIONS TO BE COORDINATED WITH ARCHITECT PRIOR TO
INSTALLATION.
ALL GYP. BD. CEILINGS TO BE PAINTED PNT- U.N.O.
CONTRACTOR TO COORDINATE LOCATIONS OF ALL ACCESS PANELS WITH ARCHITECT PRIOR TO
INSTALLATION.
ALL PERIMETER SLOT DIFFUSER BLANK OFF PLATES SHALL BE SOLID BLANK OFF PLATES.
R.C.P.'S WILL TYPICALLY INDICATE LOCATIONS, DIMENSIONS AND HEIGHTS A.F.F. OR FURRDOWNS,
VARYING CEILING MATERIALS AND THEIR LOCATIONS, HEIGHTS OF WALLS A.F.F. (FULL HEIGHT AND
PARTIAL HEIGHT), REQUIRED FIRE-RATINGS OF WALLS, AND FINAL LOCATIONS OF CEILING MOUNTED
FIXTURES/ DEVICES .
LIGHT FIXTURES IN MECHANICAL AND EQUIPMENT ROOMS ARE SHOWN FOR QUANTITY ONLY.
CONTRACTOR IS TO COORDINATE FIXTURE PLACEMENT WITH ALL MEP ITEMS AND SET FINAL FIXTURE
LOCATIONS AS REQUIRED TO EVENLY AND FULLY LIGHT ACCESSIBLE AREAS OF THE ROOM WITH THE
QUANTITY OF FIXTURES SHOWN.
PROVIDE THREE WAY LIGHT SWITCHES FOR CORRIDOR AND OPEN AREA LIGHT FIXTURES, U.N.O.,
REF. M.E.P.
THE ROOM FINISH SCHEDULE TYPICALLY INDICATES CEILING MATERIALS AND FINISHES. MATERIALS
OR FINISHES THAT VARY WITHIN A ROOM WILL BE INDICATED ON THE R.C.P.
PROVIDE ADDITIONAL SUPPORT FOR TRACK LIGHTING AS REQUIRED.
DO NOT INSTALL CEILING GRID UNTIL WORK ABOVE CEILING IS COORDINATED AND INSTALLED WITHIN
AVAILABLE PLENUM SPACE.
LIGHT FIXTURES IN MECHANICAL AND EQUIPMENT ROOMS ARE SHOWN FOR QUANTITY ONLY.
CONTRACTOR IS TO COORDINATE FIXTURE PLACEMENT WITH ALL MEP ITEMS AND SET FINAL FIXTURE
LOCATIONS AS REQUIRED TO EVENLY AND FULLY LIGHT ACCESSIBLE AREAS OF THE ROOM WITH THE
QUANTITY OF FIXTURES SHOWN.
GYP. CEILINGS AND BULKHEADS TO BE PAINTED PER DETAIL SECTIONS IF AVAILABLE AND/OR
ELEVATIONS.
ACCENT PAINT ON GYP. BOARD BULKHEADS TO BE ON BOTTOM AND SIDES OF BULKHEAD.
COORDINATE MEP / ETC. DRAWINGS FOR ALL FIXTURES/ DEVICES MOUNTED IN, ABOVE, OR HUNG
FROM THE CEILING. FINAL FIXTURE/DEVICE LOCATIONS ARE DETERMINED BY THE ARCHITECTURAL
R.C.P. WHERE CONDITIONS DIFFER SIGNIFICANTLY BETWEEN THE PLANS, REQUEST CLARIFICATION
FROM THE ARCHITECT BEFORE PROCEEDING. WHERE FIXTURES/ DEVICES SHOWN OR SPECIFIED ON
DRAWINGS OTHER THAN THE ARCHITECTURAL R.C.P.'S ARE VISIBLE AT THE CEILING PLANE,
COORDINATE LOCATIONS WITH THE ARCHITECT.
REVISIONS
This Document was
produced by or under the
direct supervision of
Registered Architect
Matthew G. Mooney
This document is
incomplete and may not be
used for regulatory
approval, permit or
construction.
Date of issue:
06/23/2014
RCP KEY NOTES
R01
KIRLIN
KREON
iLIGHT
STAIRWELL LIGHT SLF
700BCMET-Y-C-CF
18-47520-83414 / CHROME FINISH
INSPIRE-W-3000-24VDC-LENGTH
DR-WATT-24VDC-NONDIM
STRIPCHAN5FT-OUTDOOR
WATERWORKS EELT01 / CHROME FINISH
LINEAR LED LIGHT
W
A03-00
KITCHEN / BEDROOM / BATH / CLOSET
SH
5 - GARAGE ALTERNATE
SK
LINEAR FIXTURE; SURFACE MOUNT
6 - BACK OF HOUSE
V
4' STRIP PENDANT, WIRE GUARD, Y-HANGERS
8/29/2014 2:45:40 PM
COMPACT FLUORESCENT
SUBMERSION LED SPOT LIGHT, ADJUSTABLE
SUBMERSION LED SPOT LIGHT, RECESSED
SMALL LINEAR LED DOWNLIGHT
4 - SITE ALTERNATE
SJ
SMALL SQUARE CYLINDER UP/DOWN
5 - GARAGE
SK
ARCHITECTURAL ROUND GARAGE LIGHT
LOCATION
4400-10-F-BL125-A
SD
SF
SG
MINISLOT SQUARE WALL
LAMP
USAi
ATLANTIC
WATER
GARDENS
SIMES
SIMES
SIMES
SJ
CATALOG NUMBER
1.
2.
SISTEMALUX
LSR-06201-35K-WHITE
KU915901 ENGINE X 2 UP/DOWN KU715903
CHANNEL LAMP: MR16-40-B01-12-930-10-2
COLORFALLS
T-24-W35-S-LENGTH-SC-00
LED 3500K 20 WATTS
MOUNT STRAIGHT TO RECESSED J-BOX IN UNITS; CAN ALSO USE THESE IN CORRIDORS TO ADD MORE LIGHT,
UNDER CANOPY DRIVE
RETROFIT: LED 3000K SORAA EXTERIOR FAÇADE ALONG STREET, VERTICAL INSTALLATION IN WALLS, WET LOCATION. CONTRACTOR TO
MR16 GU5.3 10SP 50W PER
VERIFY CHANNEL LENGTH REQUIRED
ENGINE, 100W FOR UP/DOWN
LED 3500K
POOL FOUNTAIN, SPECIFY LENGTH & COLOR DESIRED, ACCESSORIES REQUIRED
R02
R03
R04
R05
R06
1699 HERMANN DRIVE,
HOUSTON, TEXAS 77004
TYPE
DESCRIPTION
1 - UNIT
H
BEVEL, 6" SQUARE COMPACT FLUORESCENT DOWNLIGHT WITH
TRIM
I
LED SLIMLINE
J
ISLAND PENDANT - SARA GRANDE PENDANT
MANUFACTUR
ER
GENERAL RCP NOTES
R07
R08
S.3696.19 / S.3672 / S.3670 / S.366?
S.3627.19 / S.366? / S.3670
S.7200W / S.34??
S.3842-UNV
LED 6000K 34 WATTS
LED 6000K 34 WATTS
LED 3000K 12.5 WATTS
IN FOUNTAIN CONTRACTOR TO VERIFY JUNTION BOX REQUIRED
IN POOL CONTRACTOR TO VERIFY JUNTION BOX REQUIRED
TUCKED ALONG LIP EDGE OF SHORT WALLS, FIREPIT, BARBEQUE & POOL AREAS CONTRACTOR TO VERIFY
DRIVER & WATTAGE REQUIRED
LED 3000K 2.59 WATTS PER
TUCKED UNDER LOW WALL LEDGE, OR UNDERNEATH SEATING AREAS, FIREPIT, BARBEQUE & POOL AREA ,
1FT
CONTRACTOR TO VERIFY RUN LENGTHS & DRIVERS STAIGHT OR BENDABLE IN FIELD
35W FOR 2 LAMPS T4.5 METAL SURFACE MOUNT TO BARBEQUE AREA COLUMNS
HALIDE, G8.5 BASE
R09
RCP PARTITION SYMBOLS
UNRATED PARTITION ASSEMBLY TO EXTEND TO UNDERSIDE OF CEILING OF
CEILING GRID A.F.F.
ACOUSTICALLY ATTENUATED PARTITION TO UNDERSIDE OF DECK A.F.F.
SIMES
S.3852W
LED 3200K 32 WATTS
SURFACE MOUNT TO BARBEQUE AREA COLUMNS
30 MIN. SMOKE SEAL PARTITION TO UNDERSIDE OF DECK A.F.F.
WILLIAMS
OUTDOOR
LIGHTING
ARD-PSMH-150-MED-OPTIONS-120
COMPACT FLUORESCENTS
GARAGE
1 HOUR PARTITION ASSEMBLY TO UNDERSIDE OF DECK A.F.F.
2 HOUR PARTITION ASSEMBLY TO UNDERSIDE OF DECK A.F.F.
UNRATED PARTITION ASSEMBLY TO EXTEND 6" ABOVE CEILING GRID A.F.F.
DAYBRITE
DWAE-42L-835-4-UNV / TBK
LED 3500K 40 WATTS
GARAGE
HE WILLIAMS
GLN-4-232-UP-VBY-WG11-EB2-UNV
FLUORESCENT (2) 32W T8
3500K
FLUORESECENT (2) 24-WATT
T5HO
BACK OF HOUSE
WILLIAMS
SLF-4-2-54T5H-HIA-OPTIONS-EB2-UNV
FLUORESCENT
LIGHTING
EELP
UR-EDGR-1-R-C-A-EM
RECESSED EDGE LIT, SINGLE SIDED, RED LETTERS, CLEAR, EM
NiCAD BATTERY, ALUMINUM TRIM
X2
RECESSED EDGE LIT, DOUBLE SIDED, RED LETTERS, CLEAR WITH EELP
SILVER INSERT, EM NiCAD BATTERY, ALUMINUM TRIM
6 - BACK OF HOUSE ALTERNATE
W
2' WALL MOUNTED, 50% BI-LEVEL
LAMAR
LIGHTING
LED
STAIRWELL FIXTURE
REFLECTED CEILING PLAN LEGEND
2X2 LAY-IN CEILING
LINEAR SUSPENDED
GYP. BD. CEILING
LINEAR COVE LIGHT
SCONCE FIXTURE
2X4 LAY-IN
EXIT
1X4 HUNG PARABOLIC STRIP
2X2 SUSPENDED
SUPPLY AIR DIFFUSER
2X2 LAY-IN
UR-EDGR-2-R-S-A-EM
LED
EXIT
RETURN AIR DIFFUSER
SQUARE RECESSED DOWN LIGHT
EMERGENCY EXIT FIXTURE
RECESSED LED
DLIRL-24-L-RA-W-35-W-2C-HBX
LED 3500K 15W PER 2FT
STAIRWELL FIXTURE SPECIFY OCCUPANCY SENSOR
SUSPENDED DOWN LIGHT
DECORATIVE PENDANT
1' - 0"
C
FINISHED CEILING HEIGHT A.F.F.
PG
NOTE:
ALL CEILING HEIGHTS ARE TO BE 9'-0" A.F.F. U.N.O.
B
A
REFLECTED
CEILING PLAN LEGEND &
DETAILS
JOB
DATE
SHEET
13157.0300
06/23/2014
A03-00
Download