Cut Sheet

advertisement
PXSS2K Series Compound Barrier Type Cable Connector
Flame Proof
Unarmored, Tray, Shipboard and SO Type Cable.
NEC/CEC:
Class I, Division 1  , Groups
C, D
Class I, Division 2, Groups A ,
B , C, D
NEC/CEC:
Class II, Division 2, Groups F, G
Class I, Zone 1
NEMA 4X
IP66, IP67, IP68
IECEx:
Zone 1
Ex d IIC
Ex e II
Ex nR II, Ex tD
IP66, IP67, IP68
Applications
Standard Materials
NEC/CEC Class/Zone and ATEX/IECEx/NBR IEC Zone 1 Rated Cable Glands
• Flame proof Class I cable connector suitable for unarmored,
extra hard usage, tray (TC) and shipboard cables.
Fittings
NBR IEC:
Zone 1 and 2
Ex d IIC Gb
Ex e IIC Gb
IP66
Features
• Connector provides an environmental seal on the cable jacket
and an explosionproof compound barrier seal around the cable
inner cores.
• The connector is UL Listed for NPT or Metric entry threads.
• Continuous operating temperature -60 °C to +85 °C (-76 °F to
+185 °F).
• Sealing technique - displacement seal concept. Sealing area(s)
- inner compound barrier and outer sheath.
• Connector: brass fully nickel plated
• Seal: SOLO LSF (low smoke fumes) thermoplastic elastomer
• Epoxy putty.
Options
• Aluminum: replace last digit suffix 5 with 1
• 316L stainless steel: replace last digit suffix 5 with 4
• Shroud, locknut, earth tag, entry thread seal, serrated washers,
adaptors and reducers: see Cable Gland Accessories pages.
NEC/CEC Certifications and Compliances
•
•
•
•
UL Standard: 2225
UL Listed: E161256
CSA Standard: C22.2 No. 174
CSA Certified: 101909
Minimum
Thread
Length
mm (in) E
Maximum
Number
of Cores
mm (in)
20S16PX0755
15.0 (0.59)
11.0 (0.43)
3/4
20SPX0755
15.0 (0.59)
11.0 (0.43)
20PX0505
3/4
20PX0755
15.0 (0.59)
11.0 (0.43)
1/2
20LPX0505
3/4
20LPX0755
15 (0.591)
11.0 (0.43)
25PX5
3/4
25PX0755
1
25PX1005
15.0 (0.59)
21.0 (0.83)
1.5
32PX5
1
32PX1005
1-1/4
32PX1255
15.0 (0.59)
38.0 (1.50)
M32
1.5
32LPX5
1
32LPX1005
1-1/4
32LPX1255
15 (0.591)
38.0 (1.50)
40
M40
1.5
40PX5
1-1/4
40PX1255
1-1/2
40PX1505
15.0 (0.59)
59.0 (2.32)
50S
M50
1.5
50SPX5
1-1/2
50SPX1505
50SPX2005
15.0 (0.59)
89.0 (3.50)
50
M50
1.5
50PX5
2
50PX2005
2-1/2
50PX2505
15.0 (0.59)
89.0 (3.50)
63S
M63
1.5
63SPX5
2
63SPX2005
2-1/2
63SPX2505
15.0 (0.59)
115.0 (4.53)
63
M63
1.5
63PX5
2-1/2
63PX2505
3
63PX3005
15.0 (0.59)
115.0 (4.53)
75S
M75
1.5
75SPX5
2-1/2
75SPX2505
3
75SPX3005
15.0 (0.59)
140.0 (5.51)
75
M75
1.5
75PX5
3
75PX3005
3-1/2
75PX3505
15.0 (0.59)
140.0 (5.51)
90
M90
1.5
90PX5
3
90PX3505
4
90PX4005
20.0 (0.79)
200.0 (7.87)
100
M100
2.0
100PX5
4
100PX4005
5
100PX5005
20.0 (0.79)
200.0 (7.87)
Cable
Gland
Size
Catalog Numbers
Metric
Thread C
Thread
Pitch
(mm)
Standard
Metric 
Standard NPT
Thread C
20S16
M20
1.5
20S16PX5
1/2
20S16PX0505
3/4
20S
M20
1.5
20SPX5
1/2
20SPX0505
20
M20
1.5
20PX5
1/2
20L
M20
1.5
20LPX5
25
M25
1.5
32
M32
32L
Standard NPT

Optional NPT
Thread C
2
Optional NPT
Thread 
 Extra hard usage cable cord only
 Increased thread engagement is required for gas groups A and B. Please specify gas group, thread form and size when ordering.
 Entry thread seal not supplied, see Cable Gland Accessories and Tools.
 For Nutsteel NBR IEC Brazilian Certified version with BSP threads, add an N to the beginning of the catalog number and add a B after the PX in the catalog
number, i.e. N20S16PXB0505.
160
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© April 2015
PXSS2K Series Compound Barrier Type Cable Connector
Flame Proof
Unarmored, Tray, Shipboard and SO Type Cable.
NEC/CEC:
Class I, Division 1  , Groups
C, D
Class I, Division 2, Groups A ,
B , C, D
NEC/CEC:
Class II, Division 2, Groups F, G
Class I, Zone 1
NEMA 4X
IP66, IP67, IP68
IECEx:
Zone 1
Ex d IIC
Ex e II
Ex nR II, Ex tD
IP66, IP67, IP68
NBR IEC:
Zone 1 and 2
Ex d IIC Gb
Ex e IIC Gb
IP66
IECEx Certifications and Compliances
NBR IEC Brazilian Certifications and Compliances
•
•
•
•
•
•
•
Dimensions in Millimeters (Inches)
Certification Type PX2K
Zones 1 and 2, Gas
— IEC Marking: Ex d IIC Gb, Ex e IIC Gb
INMETRO Ordinance: 179
INMETRO Certificate: TUV 12.2073-X
Ingress Protection (solid and liquid): IP66
Ex Standards: ABNT NBR IEC 60079-0; 60079-1, 60079-7
Other Standards: ABNT NBR IEC 60529 (IP)
Cable
Gland
Size
Maximum
Diameter Over
Conductors
mm (in) A
20S16
Overall Cable Diameter
mm (in) B
Across
Corners
mm (in) D
Nominal
Protrusion
Length
mm (in) F
PVC
Shroud
Reference
Cable
Connector
Weight
kgs (oz)
Max
12.6 (0.50)
3.1 (0.12)
8.7 (0.34)
30.5 (1.20)
33.6 (1.32)
58.5 (2.30)
PVC04
0.2 (7.05)
20S
12.6 (0.50)
6.1 (0.24)
11.7 (0.46)
30.5 (1.20)
33.6 (1.32)
58.5 (2.30)
PVC04
0.2 (7.05)
20
12.6 (0.50)
6.5 (0.26)
14.0 (0.55)
30.5 (1.20)
33.6 (1.32)
60.5 (2.38)
PVC05
0.25 (8.82)
20L
12.6 (0.50)
6.5 (0.26)
14.0 (0.55)
30.5 (1.20)
33.6 (1.32)
60.5 (2.38)
PVC05
0.25 (8.82)
25
17.5 (0.69)
11.1 (0.44)
20.0 (0.79)
37.5 (1.48)
41.3 (1.63)
67.5 (2.66)
PVC09
0.4 (14.22)
32
23.6 (0.93)
17.0 (0.67)
26.3 (1.04)
46.0 (1.81)
45.5 (1.79)
69.5 (2.74)
PVC10
0.56 (19.58)
32L
23.6 (0.929)
17.0 (0.67)
26.3 (1.04)
46.0 (1.81)
50.6 (1.99)
69.5 (2.74)
PVC10
0.555 (19.58)
40
30.0 (1.18)
22.0 (0.87)
32.1 (1.26)
55.0 (2.17)
60.5 (2.38)
78.0 (3.07)
PVC13
0.6 (21.16)
50S
36.6 (1.44)
29.5 (1.16)
38.2 (1.5)
60.0 (2.36)
66.0 (2.60)
75.5 (2.97)
PVC15
0.61 (21.34)
50
41.0 (1.61)
35.6 (1.40)
44.1 (1.74)
70.0 (2.76)
77.0 (3.03)
80.5 (3.17)
PVC18
0.62 (21.87)
63S
47.9 (1.89)
40.1 (1.58)
50.1 (1.97)
75.0 (2.95)
82.5 (3.25)
91.5 (3.60)
PVC21
0.71 (24.87)
63
53.7 (2.11)
47.2 (1.86)
56.0 (2.20)
80.0 (3.15)
88.0 (3.46)
92.0 (3.62)
PVC23
0.73 (25.75)
75S
59.9 (2.36)
52.8 (2.08)
62.0 (2.44)
89.0 (3.50)
97.9 (3.85)
99.0 (3.90)
PVC24
1.15 (40.57)
75
64.3 (2.53)
59.1 (2.33)
68.0 (2.68)
99.0 (3.90)
108.9 (4.29)
102.0 (4.02)
PVC26
1.15 (40.57)
90
75.3 (2.96)
66.6 (2.62)
79.4 (3.13)
114.0 (4.49)
125.4 (4.94)
120.0 (4.72)
PVC31
2.7 (95.24)
100
85.6 (3.37)
80.0 (3.15)
90.9 (3.58)
133.0 (5.24)
146.3 (5.76)
135.0 (5.31)
LSF33
3.4 (119.93)
 Extra hard usage cable cord only
 Increased thread engagement is required for gas groups A and B. Please specify gas group, thread form and size when ordering.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© April 2015
161
Fittings
Min
Across
Flats
mm (in) D
NEC/CEC Class/Zone and ATEX/IECEx/NBR IEC Zone 1 Rated Cable Glands
• Ingress Protection: IP66, IP67 and IP68, NEMA 4X
• Deluge Protection: To DTS01: 91
• Code of protection category: Ex e II, Ex nR II, Ex tD A21 IP66,
Equipment Zone I, Zone 2, Zone 21 and Zone 22 – Gas Groups
IIA, IIB, IIC
PXSS2K-REX Series Liquid Resin Barrier Type Cable Connector
Flame Proof
Unarmored, Tray, Shipboard and SO Type Cable.
NEC/CEC:
Class I, Division 1, Groups C, D
Class I, Division 2, Groups A ,
B , C, D
Class II, Division 2, Groups F, G
NEC/CEC:
Class I, Zone 1
NEMA 4X
IP66, IP67, IP68
IECEx:
Zone 1
Ex d IIC
Ex e II
Ex nR II, Ex tD
IP66, IP67, IP68
Applications
Standard Materials
NEC/CEC Class/Zone and ATEX/IECEx/NBR IEC Zone 1 Rated Cable Glands
• Flame proof Class I cable connector suitable for unarmored,
extra hard usage, tray (TC) and shipboard cables.
Fittings
NBR IEC:
Zone 1 and 2
Ex d IIC Gb
Ex e IIC Gb
IP66
• Connector: brass fully nickel plated
• Seal: SOLO LSF (low smoke fumes) thermoplastic elastomer
• High speed liquid resin sealing compound.
Features
• Utilizes RapidEx high speed liquid resin sealing compound
included with each gland.
• The gland utilizes a liquid pour resin seal that vastly reduces
installation time and associated costs. This solution is
particularly effective on multicore cables where traditional
compound is difficult and time consuming to apply.
• Connector provides an environmental seal on the cable jacket
and an explosionproof liquid resin barrier seal around the cable
inner cores.
• Continuous operating temperature -60 °C to +100 °C (-76 °F to +212 °F).
• Sealing technique - displacement seal concept. Sealing area(s) - inner liquid resin barrier and outer sheath.
Cable
Gland
Size
Metric
Thread C
Thread
Pitch
(mm)
20S/16
M20
1.5
20S
M20
20
Options
• Aluminum: replace last digit 5 with 1
• 316L stainless steel: replace last digit 5 with 4 (available by
quote only)
• Shroud, locknut, earth tag, entry thread seal, serrated washers,
adaptors and reducers: see Cable Gland Accessories pages
NEC/CEC Certifications and Compliances
• UL Standard: 2225
• CSA Standard: C22.2 No. 174
• CSA Certified: 101909
Replacement
Sealing
Resin
Maximum
Diameter Over
Conductors
mm (in) A
Standard NPT
Thread C
Standard NPT

Optional NPT
Thread C
2016SPXREX5X
1/2
20S16PXREX0505X
3/4
20S16PXREX0755X RAPIDEX30
12.6 (0.50)
1.5
20SPXREX5X
1/2
20SPXREX0505X
3/4
20SPXREX0755X
RAPIDEX30
12.6 (0.50)
M20
1.5
20PXREX5X
1/2
20PXREX0505X
3/4
20PXREX0755X
RAPIDEX30
12.6 (0.50)
20L
M20
1.5
20LPXREX5X
1/2
20LPXREX0505X
3/4
20LPXREX0755X
RAPIDEX30
12.6 (0.50)
25
M25
1.5
25PXREX5X
3/4
25PXREX0755X
1
25PXREX1005X
RAPIDEX30
17.5 (0.69)
32
M32
1.5
32PXREX5X
1
32LPXREX1005X
1-1/4
32LPXREX1255X
RAPIDEX30
23.6 (0.93)
32L
M32
1.5
32LPXREX5X
1
32PXREX1005X
1-1/4
32PXREX1255X
RAPIDEX30
23.6 (0.93)
40
M40
1.5
40PXREX5X
1-1/4
40PXREX1255X
1-1/2
40PXREX1505X
RAPIDEX30
30.0 (1.18)
50S
M50
1.5
50SPXREX5X
1-1/2
50SPXREX1505X
50SPXREX2005X
RAPIDEX80
36.6 (1.44)
50
M50
1.5
50PXREX5X
2
50PXREX2005X
2-1/2
50PXREX2505X
RAPIDEX80
41.0 (1.61)
63S
M63
1.5
63SPXREX5X
2
63SPXREX2005X
2-1/2
63SPXREX2505X
2RAPIDEX80
47.9 (1.89)
63
M63
1.5
63PXREX5X
2
63PXREX2005X
2-1/2
63PXREX2505X
2RAPIDEX80
53.7 (2.11)
75S
M75
1.5
75SPXREX5X
75SPXREX3005X
3RAPIDEX80
59.9 (2.36)
75
M75
1.5
75PXREX5X
3
75PXREX3005X
3-1/2
75PXREX3505X
3RAPIDEX80
64.3 (2.53)
90
M90
2.0
90PXREX5X
3-1/2
90PXREX3505X
4
90PXREX4005X
3RAPIDEX80
75.3 (2.96)
Standard Metric

2-1/2
75SPXREX2505X
2
3
Optional NPT

 Increased thread engagement is required for gas groups A and B. Please specify gas group, thread form and size when ordering.
 Entry thread seal not supplied, see Cable Gland Accessories and Tools.
 For Nutsteel NBR IEC Brazilian Certified version with BSP threads, add an N to the beginning of the catalog number and add a B after the PX in the catalog number, i.e.
N20S16PXB0505.
162
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© April 2015
PXSS2K-REX Series Liquid Resin Barrier Type Cable Connector
Flame Proof
Unarmored, Tray, Shipboard and SO Type Cable.
NEC/CEC:
Class I, Division 1, Groups C, D
Class I, Division 2, Groups A ,
B , C, D
Class II, Division 2, Groups F, G
NEC/CEC:
Class I, Zone 1
NEMA 4X
IP66, IP67, IP68
IECEx:
Zone 1
Ex d IIC
Ex e II
Ex nR II, Ex tD
IP66, IP67, IP68
NBR IEC:
Zone 1 and 2
Ex d IIC Gb
Ex e IIC Gb
IP66
IECEx Certifications and Compliances
NBR IEC Brazilian Certifications and Compliances
•
•
•
•
•
•
•
Certification Type PX2K
Zones 1 and 2, Gas
— IEC Marking: Ex d IIC Gb, Ex e IIC Gb
INMETRO Ordinance: 179
INMETRO Certificate: TUV 12.2073-X
Ingress Protection (solid and liquid): IP66
Ex Standards: ABNT NBR IEC 60079-0; 60079-1, 60079-7
Other Standards: ABNT NBR IEC 60529 (IP)
Cable
Gland
Size
Maximum
Cable Bedding
Diameter
mm (in) G
Minimum
Thread
Length
mm (in) E
20S/16
13.0 (0.51)
20S
Cable Bedding Diameter
mm (in) B
Dimensions in Millimeters (Inches)
Across
Corners
mm (in) D
Protrusion
Length
mm (in) F
PVC
Shroud
Reference
Cable
Connector
Weight
kg (oz)
Max
15.0 (0.59)
3.2 (0.13)
8.7 (0.34)
30.5 (1.20)
30.5 (1.20)
58.5 (2.30)
PVC04
0.2 (7.05)
13.0 (0.51)
15.0 (0.59)
6.1 (0.24)
11.7 (0.46)
30.5 (1.20)
30.5 (1.20)
58.5 (2.30)
PVC04
0.2 (7.05)
20
13.0 (0.51)
15.0 (0.59)
6.5 (0.26)
14.0 (0.55)
30.5 (1.20)
30.5 (1.20)
60.5 (2.38)
PVC05
0.25 (8.82)
20L
14.1 (0.56)
15 (0.59)
9.9 (0.39)
16.0 (0.63)
30.5 (1.20)
33.6 (1.30)
60.5 (2.38)
PVC05
0.2 (7.09)
25
18.0 (0.71)
15.0 (0.59)
11.1 (0.44)
20.0 (0.79)
37.5 (1.48)
37.5 (1.48)
67.5 (2.66)
PVC09
0.4 (14.22)
32
24.0 (0.94)
15.0 (0.59)
17.0 (0.67)
26.3 (1.04)
45.5 (1.79)
45.5 (1.79)
69.5 (2.74)
PVC10
0.56 (19.58)
32L
26.4 (1.04)
15 (0.59)
20.0 (0.79)
27.4 (1.08)
46.0 (1.81)
50.6 (1.99)
69.5 (2.74)
PVC10
0.45 (15.75)
40
30.4 (1.2)
15.0 (0.59)
22.0 (0.87)
32.1 (1.26)
55.0 (2.17)
55.0 (2.17)
78.0 (3.07)
PVC13
0.6 (21.16)
50S
37.0 (1.46)
15.0 (0.59)
29.5 (1.16)
38.2 (1.5)
60.0 (2.36)
60.0 (2.36)
60.0 (2.36)
PVC15
0.61 (21.34)
50
41.4 (1.63)
15 (0.59)
35.6 (1.4)
44.1 (1.74)
70.0 (2.76)
70.0 (2.76)
80.5 (3.17)
PVC18
0.62 (21.87)
63S
48.5 (1.91)
15.0 (0.59)
40.1 (1.58)
50.1 (1.97)
75.0 (2.95)
75.0 (2.95)
91.5 (3.60)
PVC21
0.71 (24.87)
63
54.2 (2.13)
15.0 (0.59)
47.2 (1.86)
56.0 (2.2)
80.0 (3.15)
80.0 (3.15)
92.0 (3.62)
PVC23
0.73 (25.75)
75S
60.3 (2.37)
15 (0.59)
52.8 (2.08)
62.0 (2.44)
89.0 (3.50)
89.0 (3.50)
99.0 (3.90)
PVC24
1.15 (40.57)
75
64.7 (2.55)
20.0 (0.79)
59.1 (2.33)
68.0 (2.68)
99.0 (3.90)
99.0 (3.90)
102.0 (4.02)
PVC26
1.15 (40.57)
90
75.7 (2.98)
20.0 (0.79)
66.6 (2.62)
80.0 (3.15)
114.0 (4.49)
114.0 (4.49)
120.0 (4.72)
PVC31
2.70 (95.24)
 Increased thread engagement is required for gas groups A and B. Please specify gas group, thread form and size when ordering.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© April 2015
163
Fittings
Min
Across
Flats
mm (in) D
NEC/CEC Class/Zone and ATEX/IECEx/NBR IEC Zone 1 Rated Cable Glands
• Ingress Protection: IP66, IP67 and IP68, NEMA 4X
• Deluge Protection: To DTS01: 91
• Code of protection category: Ex e II, Ex nR II, Ex tD A21 IP66,
Equipment Zone I, Zone 2, Zone 21 and Zone 22 – Gas Groups
IIA, IIB, IIC
Download