BFOU (c) 150/250(300)V S4/S8 MGT/EPR/EPR/TCWB/EVA Fire resistant, flame retardant halogen-free instrumentation cable Mud resistant Applicable standards: NEK TS 606 Code S4/S8, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC 60332-1, IEC 60332-3-22 Flame retardant, IEC 60331 Fire resistant IEC 60754-1,2 Halogen free, IEC 61034-1,2 Low Smoke CONSTRUCTION Code Letter Conductors Insulation Tinned annealed circular stranded copper according to IEC 60228 class 2 B Mica tape EP rubber thermosetting compound ,IEC 60092-351 (EPR) Inner covering F Color coded cores twisted together and wrapped with polyester tape. Pairs/ Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire .Pairs/ triples are identified by numbers printed directly on the insulated conductors. Flame retardand and halogen free thermosetting compound Armour/screen O Tinned annealed copper wire braid Pair, Triple, Quad twisting Separator Outer sheath Separator, suitable tape between the braid and outer sheath U Flame retardand, halogen free and mud resistant thermosetting compound SHF2 (IEC 60092-359) Colour of outer sheath Grey or Blue Standard marking E.g. TF KABLE 3 BFOU (c) 250V S4/S8 2 PAIR 0,75mm2 IEC 60331-21 IEC 603323-22 IEC 60092-376 TELE-FONIKA Kable S.A. www.tfkable.com BFOU_C_250V_AJ/KHB 04-02-15 BFOU (c) 150/250(300)V S4/S8 MGT/EPR/EPR/TCWB/EVA FEATURES Maximum conductor operating temperature: +90°C Maximum conductor temperature during short circuit: +250oC Lowest ambient temperature for fixed installation: -40°C Lowest installation temperature: -15°C Minimum bending radius: 6 D D – overall diameter of cable Flame retardant: IEC 60332-3-22 (Category A) Fire resistant: IEC 60331 Smoke emission: IEC 61034-2 Corrosive gas emission: IEC 60754-1 Oil resistance: IEC 60092-359 SHF2, IRM 902 (100⁰C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) APPLICATIONS Fixed installation for instrumentation ,communication, control and alarm system in both EX -and safe areas emergency and critical systems where requirements for fire resistance exists. Meets the MUD resistance requirement in NEK TS 606 Other industrial applications Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request TELE-FONIKA Kable S.A. www.tfkable.com BFOU_C_250V_AJ/KHB 04-02-15 BFOU (c) 150/250(300)V S4/S8 MGT/EPR/EPR/TCWB/EVA Size N x 2 x mm2 2x2x0,75 4x2x0,75 8x2x0,75 12x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 N x 3 x mm2 2x3x0,75 4x3x0,75 8x3x0,75 12x3x0,75 16x3x0,75 N x 2 x mm2 3x2x1,0 4x2x1,0 N x 2 x mm2 2x2x1,5 4x2x1,5 8x2x1,5 12x2x1,5 16x2x1,5 N x 3 x mm2 2x3x1,5 4x3x1,5 8x3x1,5 12x3x1,5 N x 2 x mm2 2x2x2,5 4x2x2,5 8x2x2,5 16x2x2,5 N x 3 x mm2 4x3x2,5 8x3x2,5 Class of conductor Insulation Thickness Thickness of inner sheath Thickness of outer sheath Approximate Approximate overall net weight diameter of cable 2 2 2 2 2 2 2 mm 0,6 0,6 0,6 0,6 0,6 0,6 0,6 mm 1,1 1,1 1,1 1,4 1,9 1,9 2,3 mm 1,3 1,4 1,5 1,6 1,7 1,8 2 mm 13,7 19,0 23,4 28,0 32,3 34,6 39,0 kg/km 258 416 612 842 1104 1247 1561 2 2 2 2 2 0,6 0,6 0,6 0,6 0,6 1,1 1,1 1,1 1,4 2,1 1,3 1,4 1,6 1,8 1,9 18,2 20,5 22,7 31,5 36,8 372 497 703 1091 1463 2 2 0,7 0,7 1,1 1,1 1,4 1,4 19,0 20,6 418 482 2 2 2 2 2 0,7 0,7 0,7 0,7 0,7 1,1 1,1 1,1 1,4 1,9 1,4 1,4 1,7 1,8 1,9 15,5 21,8 27,5 32,9 38,0 337 551 868 1207 1580 2 2 2 2 0,7 0,7 0,7 0,7 1,1 1,1 1,1 1,4 1,4 1,5 1,8 1,9 21,0 23,8 31,4 36,9 492 687 1139 1578 2 2 2 2 0,7 0,7 0,7 0,7 1,1 1,1 1,1 2,3 1,4 1,5 1,8 2,1 16,6 23,7 30,1 42,9 402 683 1103 2228 2 2 0,7 0,7 1,1 1,1 1,6 1,9 26,0 34,4 929 1472 TELE-FONIKA Kable S.A. www.tfkable.com BFOU_C_250V_AJ/KHB 04-02-15 BFOU (c) 150/250(300)V S4/S8 MGT/EPR/EPR/TCWB/EVA All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time TELE-FONIKA Kable S.A. www.tfkable.com BFOU_C_250V_AJ/KHB 04-02-15