RF-LAMBDA

advertisement
RF-LAMBDA
RVPT0501GBC
LEADER OF RF BROADBAND SOLUTIONS
Voltage Control Phase Shifter 0.5-1GHz
Features
Wide Band Operation 0.5‐1GHz
360° Phase Shift
Low Insertion Loss and Low Phase Error
Singe Control Operation
Customization available upon request
Electrical Specifications, TA = +25° C, 50 Ohm System
PN:RVPT0501GBC
Description
Voltage Control Phase Shifter
Parameters
Min
Frequency Range
0.5
Typ.
Max
Units
1
GHz
Phase Range
360
deg
Phase Error
±20
deg
Insertion Loss 3.0
Insertion Loss Temperature Coefficient
0.01
dB/ °C
Input Return loss
15
dB
Output Return loss
15
dB
Input Power for 1 dB Compression
23
dBm
15
V
current
5
mA
Impedance
50
Ω
Weight 1.76
ounces
Control Voltage
0
4.0
Input /Output Connector
SMA‐Female
Finishing
Gold Plating
Material Aluminium
Seal
dB
Voltage Control Phase Shifter 0.5-1GHz
•
•
•
•
•
Hermetically Sealed(optional)
RF-LAMBDA USA
Sales: sales@rflambda.com
www.rflambda.com
Technical : support@rflambda.com
RF-LAMBDA
RVPT0501GBC
LEADER OF RF BROADBAND SOLUTIONS
Absolute Maximum Ratings Environment specifications
Control Voltage 0~ 20V
Operational Temperature (°C) ‐45 ~ +85
Altitude
60,000 ft 1.0psi min (Hermetically Seal Un‐controlled environment) (Optional)
Ordering Information
Part No
ECCN
Description
0.5‐1GHz Voltage Control RVPT0501GBC EAR99 Phase Shifter
Vibration
25g rms (15 degree 2KHz) endurance, 1 hour per axis
Humidity
100% RH at 35c, 95%RH at 40 deg c
Shock
20G for 11msc half sin wave,3 axis both directions
Typical performance plots
Insertion Loss vs. Frequency
Input Return Loss vs. Frequency
Insertion Loss vs. Frequency
-1.5
-10
Input Return Loss vs. Frequency (Major Voltages)
-15
-2
Return Loss(dB)
Insertion Loss(dB)
-20
-2.5
-3
-3.5
-25
-30
Voltage Control Phase Shifter 0.5-1GHz
Storage Temperature (°C) ‐50 ~ +125
30,000 ft. (Epoxy Seal Controlled environment)
RF Input power 23dBm
Operating Temperature (°C) ‐45 ~ +85
Storage Temperature (°C) ‐50 ~ +125
-35
-40
-45
-50
-55
-4
0.5
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1
-60
0.5
Frequency(GHz)
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1
0.9
0.95
1
Frequency(GHz)
Output Return Loss vs. Frequency
Phase Shift vs. Frequency Output Return Loss vs. Frequency (Major Voltages)
-10
Phase Shift vs. Frequency
400
350
300
Phase Shift(Degrees)
Return Loss(dB)
-15
-20
-25
250
200
150
100
50
-30
0
-35
0.5
0.55
0.6
0.65
0.7
0.75
0.8
Frequency(GHz)
0.85
0.9
0.95
1
-50
0.5
0.55
0.6
0.65
0.7
0.75
0.8
0.85
Frequency(GHz)
RF-LAMBDA USA
Sales: sales@rflambda.com
www.rflambda.com
Technical : support@rflambda.com
RF-LAMBDA
RVPT0501GBC
LEADER OF RF BROADBAND SOLUTIONS
Phase Shift vs. Voltage Attenuation vs. Frequency
Phase Shift vs. Voltage
400
Attenuation vs. Frequency
0.6
350
0.5
0.4
Attenuation(dB)
250
200
150
100
0.2
0.1
0
50
0.5GHz
0.75GHz
1GHz
0
-50
0.3
0
5
10
-0.1
-0.2
0.5
15
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1
Frequency(GHz)
Voltage(V)
Outline Drawing: All Dimensions in mm(inches)
5 [0.20]
30.5 [1.20]
26.1 [1.03]
10 [0.39]
39.5 [1.55]
79 [3.11]
74.6 [2.94]
RF-Lambda
IN
RVPT0501GBC
F:0.5-1GHz
OUT
SN:XXXXXXXXXXX
VCC GND
Voltage Control Phase Shifter 0.5-1GHz
Phase Shift(Degrees)
300
4- 2.3[0.09]
THRU
Important Notice
The information contained herein is believed to be reliable. RF‐Lambda makes no warranties regarding the information contained herein.
RF‐Lambda assumes no responsibility or liability whatsoever for any of the information contained herein. RF‐Lambda assumes no responsibility
or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and
with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to
change without notice. Customers should obtain and verify the latest relevant information before placing orders for RF‐Lambda products. The
information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or
any other intellectual property rights, whether with regard to such information itself or anything described by such information.
RF‐Lambda products are not warranted or authorized for use as critical components in medical, life‐saving, or life sustaining applications, or
other applications where a failure would reasonably be expected to cause severe personal injury or death.
RF-LAMBDA USA
Sales: sales@rflambda.com
www.rflambda.com
Technical : support@rflambda.com
Download