Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE 2015 Revision 1.0 Table of Contents Table of Contents About Us - Company Profile 02 Online UPS 04 Professional Series (1P/1P) - Tower 04 Professional Series (1P/1P) - Dual 06 Master Series (1P/1P) - Tower 08 Master E Series (1P/1P) - Tower 12 Master Series (1P/1P) - 2-in-1 Rack/ Tower 14 Master Series (3P/1P) - Tower 19 Master E Series (3P/1P) - Tower 22 Master Series (3P/1P) - Rack Mount 25 Master Series (3P/3P) - Tower 27 Master E Series (3P/3P) - Tower 29 Power Series 31 Power E Series 36 PPM Series 41 PRO-R Series 44 PRO-M Series 46 PRO-EM Series 49 Giant Series 52 Jupiter Series 54 Line Interactive UPS 58 PRO SFC Series 58 PRO SFT Series 60 PRO Series 62 PRO-L Series 64 PRO Rack/ Tower Series 66 Outdoor Line Interactive Series 68 Inverter UPS 70 Inverter Series 70 Auto Voltage Regulator 74 PVR Series 74 DC UPS 75 PDC Series 75 PBU Series 76 Solar UPS 77 Zonne Series 77 PPS Series 79 PCC Series 81 PSI Hybrid Series 83 PSI On-Grid Amnets Series 84 PSI Off-Grid Haus Series 85 PSI Off-Grid Haus MPPT Series 86 Software & Accessories 89 Appendix 94 01 About Us - Company Profile Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in the area of Back-up UPS products. Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively. The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices. Our Mission Accentuate The Best For The E-generation PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace. PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency. Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure. Our Vision Ideas, Innovation and Information PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suitable for their technology advanced environments. The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries. 02 About Us - Company Profile Core Values Secured Information Management With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly. Innovative Design Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in. Superior Service Standards Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product. Total Quality Assurance System Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies. Range of UPS The wide range of our products gives you an infinite range of solutions: 1. Online UPS 2. Line Interactive UPS 3. Inverter UPS 4. DC UPS 4. Solar UPS 03 Online UPS Professional Series (1P/1P) - Tower Online Professional Series 1kVA – 6kVA Small Computer Network Local Area Network (LAN) Work-Stations Servers Professional Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses online double conversion technology. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. This device is able to provide high-efficiency charging with its high input power factor correction. Professional Series is available in capacities ranging from 1000VA to 6000VA. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. Users can also have the option to top-up an additional isolation transformer to obtain pure and clean power for their sensitive devices. • • • • • • • • • True Double-Conversion Online UPS Wide input voltage range (110~300VAC) Input Power Factor correction of 0.98 Output Power Factor of 0.8 Generator compatible LCD User Interface Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface Smart battery charger designed to optimize battery performance Isolation transformer (optional) Rear Panel For 1kVA to 6kVA model 1. 2. 3. 4. 5. 6. 7. 8. 9. Output receptacles AC input Input circuit breaker Network/Fax Modem Surge Protection Intelligent slot for communication port/ SNMP. (standard come with USB port) External battery connection (only available for L model) Output terminal Output circuit breaker Fan 5 5 4 5 6 9 1 PRO901S/L PRO902S/L 3 9 1 7 6 8 8 9 4 3 2 4 6 1 2 7 2 PRO903S/L PRO906S/L 04 Online UPS Options • • • • • RS-232 Port (communication interface) AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection Output Isolation Transformer External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only) Full Specifications MODELS PRO901S/ L PRO902S/ L PRO903S/ L PRO906S/ L Capacity 1000 VA 2000 VA 3000 VA 6000 VA INPUT Voltage Range 110-300 VAC ± 5 % Frequency Range 40 ~ 70Hz (Auto sensing) ≧ 0.98 @ Nominal Voltage (100% load) Power Factor OUTPUT Output Voltage 200/208/220/230/240 VAC or 100/110/115/120/127 VAC Voltage Regulation (Batt. Mode) ±1% 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Synchronized Range) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz Frequency Range (Batt. Mode) Current Crest Ratio 3:1 Harmonic Distortion ≦ 3 % THD (Linear Load), ≦ 7 % THD (Non-linear Load) Transfer Time Zero AC Mode to Batt. Mode 4 ms (Typical) Inverter to Bypass Waveform (Batt. Mode) Pure Sinewave EFFICIENCY Up to 88% AC Mode BATTERY Type Standard Model Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH Recharge Time (Typical) Back to 90% capacity in 9 hours 10AH Charging Current 1.0A (max) Type Long-Run Model Depending on the application Capacity Charging Current Depending on the application 1A / 2A / 4A / 8A (Default) 1A / 2A / 4A / 6A (Default) OVERLOAD 100% < Load < 110% Overload warning only (No shutdown) 110% < Load <130% 30 seconds >130% 1.5 seconds INDICATORS Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions LCD Display PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) 17.2 397×145×220 Dimension (mm) D × W × H Net Weight (kgs) 421 × 190 × 318 397 x 145 x 220 10.8 36.2 421×190×318 426×190×318 13.1 15.2 8.9 5.7 426 × 190 × 318 28.7 ENVIRONMENT Operation Humidity <90% (Non-condensing) Ambient Temperature 0°C - +40°C Noise Level ≤ 45dB @ 1 Meter Regulations Safety: EN62040-1-1; EMI62040-2; EN62040-3 < 55dB @ 1 Meter MANAGEMENT USB Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 05 Online UPS Professional Series (1P/1P) - Dual Online Professional Series 1kVA – 3kVA Small Computer Network Local Area Network (LAN) Work-Stations Servers Professional Series (1P/1P) - Dual is an advanced yet affordable single-phase UPS system that uses on-line double conversion technology with 2 different input voltage ranges. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. Professional Series (1P/1P) – Dual is most suitable to be used in areas that are plagued by voltages that are as low as 100V. With the advanced double-conversion technology, the dual series is able to regulate and maintain consistent output even when it is fully loaded. Also, this device is able to provide full isolation and complete common mode noise rejection from complementary equipment. The Dual Series is available in various capacities, ranging from 1000VA to 3000VA. • True double-conversion • Accepts dual input voltage for special power environment with High Voltage and Low Voltage • Complete galvanic isolation design offers full isolation and complete common mode noise rejection • Wide input voltage range (88-144VAC and 176-288VAC) at full load • Selectable output voltage at 110VAC or 220VAC • ECO mode for energy saving • Input power factor correction 0.99 • Output voltage regulation < ± 1% • Mini slot for USB / RS-232 / AS400 / SNMP communication • Smart battery charger design for optimized battery performance Rear Panel 5 For 1kVA to 3kVA model 1. 2. 3. 4. 5. 6. 7. 8. 9. Output receptacles AC input Input circuit breaker Network/Fax/Modem surge protection Intelligent slot for communication port/SNMP (standard come with USB port) External battery terminal (only available for Long-run model) Output terminal Output circuit breaker Fan 5 4 4 5 6 9 4 6 9 1 9 1 3 9 2 8 6 1 9 2 7 2 9 9 9 PRO901DS/DL PRO902DS/DL PRO903DS/DL 06 Online UPS Options • • • • RS-232 Port (communication interface) AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only) Full Specifications MODELS PRO901DS/DL PRO902DS/DL PRO903DS/DL Capacity 1000 VA 2000 VA 3000 VA INPUT Nominal Voltage 110/115/120/127 VAC or 208/220/230/240 VAC (Auto sensing) Voltage Range 88-144 VAC and 176 - 288 VAC (Auto sensing) Frequency Range 45Hz ~ 55 Hz or 56Hz ~ 65 Hz ≧ 0.99 @ Nominal Voltage (100% Load) Power Factor OUTPUT Output Voltage 110/115/120/127 VAC or 208/220/230/240 VAC AC Voltage Regulation (Static) ± 1% Frequency Range (Synchronized Range) 47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz Frequency Range (Batt. Mode) 50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz Current Crest Ratio 3:1 Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 6 % THD (Non-linear Load) Zero AC Mode to Battery Mode Transfer Time 4 ms (Typical) AC Mode to Bypass Bypass to AC Mode 4 ms (Typical) Waveform (Batt. Mode) Pure Sinewave EFFICIENCY (Peak) AC Mode (@100% RCD load) 76% (Typical); 78% (Peak) 77% (Typical); 79% (Peak) 78% (Typical); 80% (Peak) Battery Mode(@100% RCD load) ECO Mode 84% (Typical); 86% (Peak) 85% 86% (Typical); 88% (Peak) 88% 87% (Typical); 89% (Peak) 90% BATTERY Battery Type Standard Model Battery Numbers 12V / 9Ah 2 4 Recharge Time (Typical) Charging Current Charging Voltage 1.0A (max) 27.4 VDC ± 1% 54.8 VDC ±1% Charging Current Charging Voltage 82.2 VDC ±1% Depending on application Battery Type and Numbers Long-Run Model 6 Back to 90% capacity in 5 hours 4A or 8A 27.4 VDC ± 1% 54.8 VDC ±1% 82.2 VDC ±1% INDICATORS UPS status, Load level, Battery level, Input / Output / battery info, Discharge timer, and Fault conditions LCD Panel ALARM Battery Mode Sounding every 4 seconds Sounding every second Low Battery Sounding twice every second Overload Continously sounding Fault PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) 423 x 145 x 332 26.5 426 x 190 x 448 34 426 x 190 x 448 56 Dimension (mm) D × W × H 423 x 145 x 332 426 x 190 x 448 426 x 190 x 448 21.5 23 41 Net Weight (kgs) ENVIRONMENT Operation Humidity 20-95 % RH @ 0- 40°C (Non-condensing) Noise Level Less than 50dBA @ 1 Meter MANAGEMENT Communication Optional SNMP RS232 Card / Optional USB Card, SNMP Card, or AS400 Card Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 07 Online UPS Master Series (1P/1P) - Tower Online Master Series 1kVA – 10kVA Small Computer Network Local Area Network (LAN) Work-Stations Servers Master Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrial applications. The Master series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Master series (1P/1P) also comes in various capacities ranging from 1kVA to 10kVA to suit your needs. The 6kVA and 10kVA UPS system comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other. • True Double-Conversion Online UPS • Output Power Factor 0.8 • Wide input voltage range (110~300V) • Programmable power management outlets • 50/60 Hz Frequency Converter Mode • ECO mode operation for energy saving • Emergency Power Off (EPO) Function • SNMP/USB+RS-232 multiple communications (SNMP is optional) • DSP technology applied for 6K and up models • Smart battery charger design to optimize battery performance • Maintenance bypass available for 6K and up models • Optional hot standby mode and N+X parallel redundancy available for 6K and up models • Adjustable battery numbers for 6K and up models • Built-in isolation transformer (Option) Rear Panel For 1kVA to 3kVA model 1. Programmable outlets: connect to non-critical loads 2. Output receptacles: connect to mission critical loads 3. AC input 4. Input circuit breaker 5. Network/ Fax/ Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. External battery connection (only available for L model) 11. Output terminal 12. Output circuit breaker 13. Fan 7 7 8 6 13 4 9 7 6 9 5 8 3 PRO801S/L PRO8015S/L 10 5 10 13 12 1 2 9 6 5 13 10 8 13 4 13 2 1 3 4 3 PRO802S/L 2 1 11 PRO803S/L 08 Online UPS For 6kVA to 10kVA model 1 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Input circuit breaker 11. Input/Output terminal 12. Output terminal 1 13. Output terminal 2 14. External battery terminal (only available for Long-run model) 15. Utility input terminal 16. Output IEC Socket 2 3 4 5 5 6 8 7 14 8 9 10 16 12 13 15 11 PRO806S/L PRO810S/L Battery Pack For 1kVA to 3kVA model Model Battery Type Battery Number (max) G6 G12 G18 12V7AH 12V9AH 12V7AH 12V9AH 12V7AH 12V9AH 6 pcs 6 pcs 12 pcs 12 pcs 18 pcs 18 pcs Dimension (DxWxH) mm 397 × 145 × 220 421 × 190 × 318 535 × 190 × 318 Weight (kg) 18 36 55 20 40 61 For 6kVA to 10kVA model Model Battery Type Battery Number (max) Dimension (DxWxH) mm Weight (kg) G40 G60 12V7AH 12V9AH 40 pcs 40 pcs 592 × 250 × 576 109 125 12V7AH / 12V9AH 60 pcs 60 pcs 830 × 250 × 576 166 190 09 Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • Output Isolation Transformer • External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA) Full Specifications MODELS PRO801S/ L PRO8015S/ L PRO802S/ L Phase PRO803S/ L PRO806S/ L PRO810S/ L 6000 VA 10000 VA Single phase with ground Capacity 1000 VA INPUT Nominal Voltage 1500 VA 2000 VA 3000 VA 200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VAC 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load 110-300 VAC at 50% load 176-300 VAC at 100% load Voltage Range Frequency Range 40 ~ 70Hz 46 ~ 54 Hz or 56 ~ 64 Hz ≧ 0.99 @ Nominal Voltage (100% Load) ≧0.99 @ 100% Load 200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VAC Power Factor OUTPUT Output Voltage Voltage Regulation (Batt. Mode) ±1% Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) 47~53 Hz or 57~63 Hz 46 ~ 54 Hz or 56 ~ 64 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 3:1 Current Crest Ratio ≦ 2 % THD (Linear Load) ≦ 4 % THD (Non-linear Load) Harmonic Distortion Transfer Time ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) Zero AC Mode to Batt. Mode 4 ms (Typical) Inverter to Bypass Zero Waveform (Batt. Mode) Pure Sinewave EFFICIENCY AC Mode 87% 90% 89% Battery Mode 83% 87% 88% BATTERY Type 12 V / 7 Ah Number Standard Model 12 V / 9 Ah 12 V / 7 Ah 3 Recharge Time (Typical) 12 V / 7 Ah 12 V / 9 Ah 20 Back to 90% Back to 90% capacity in 7 hours capacity in 9 hours Back to 90% capacity in 4 hours Charging Current 1.0A (max) Charging Voltage 41.0 VDC ± 1% Battery Type Long-Run Model 12 V / 9 Ah 6 Numbers 82.1 VDC ±1% Depending on the application 273.0 VDC ±1% 6 18-20 82.1 VDC ±1% 273.0 VDC ±1% 3 8.0A Charging Current Charging Voltage 4.0A 41.0 VDC ± 1% INDICATORS UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions LCD Display ALARM Battery Mode Sounding every 4 seconds Sounding every second Low Battery Overload Sounding twice every second Fault Continuously sounding PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) 14 26 397×145×220 Dimension (mm) D × W × H Net Weight (kgs) 421 × 190 × 318 397 x 145 x 220 13 7 592 x 250 x 576 28 81 421×190×318 7 13 83 592 x 250 x 576 13 25 27 Less than 55dB@1Meter Less than 58dB@1Meter ENVIRONMENT Operation Humidity Noise Level MANAGEMENT Smart RS-232 USB Optional SNMP 20-90 % RH @ 0- 40°C (Non-condensing) Less than 50dB@1Meter Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 10 Online UPS True double-conversion Online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications. Output Power factor of 0.8 As compared to the online UPS models in the current market, the Master Series (1P/1P) provides better output power factor of up to 0.8. This unit is able to offer higher performance and efficiency for your critical applications. Wide Input Voltage Range (110 V -300 V) Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments. Programmable Power Management Outlets The programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices. Programmable Outlets (P1) - connect to non-critical devices 50/60 Hz Frequency Converter Mode Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments. ECO Mode Operation For Energy Saving Offers efficiency as high as 97% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises. Emergency Power Off (EPO) Function This feature can protect the personnel and the equipment in the case of fire outbreak or other types of emergency. SNMP + USB + RS-232 Multiple Communication port for Models ranging from 1 to 3kVA. This feature allows either the USB or RS-232 communication port to simultaneously operate with the SNMP interface. Higher Accuracy for Output Voltage The advanced control firmware allows the Master Series (1P/1P) to achieve higher accuracy with the output voltage tolerance of +/- 1%. The device is applicable for the use with critical test and IT equipments. Smart Battery Charger Design to Optimise Battery Performance Master Series (1P/1P) 1-3kVA models are equipped with a 2-stage charger design to guarantee precise battery discharge time. The charging voltage is also automatically adjusted according to the ambient temperature, to lengthen the service life of the battery. The 6kVA and 10kVA models come with an additional extendable charger that allows for large-capacity battery charging. DSP Technology (Applies for the above models) A DSP controller improves the performance and efficiency of the UPS. Maintenance Bypass Available For 6kVA And Above Models Internal bypass assures continuous power to critical devices during UPS maintenance. Optional Hot Standby and N+X Parallel Redundant System (Available for Models ranging from 6kVA and above) An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other. 11 Online UPS Master Series (1P/1P) - Tower Online Master E Series 6kVA – 10kVA Small Computer Network Local Area Network (LAN) Work-Stations 0.9 Output Power Factor Servers Master E Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrial applications. The Master E Series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The E-Series provides better output power factor of up to 0.9, offering high performance and efficiency for your critical applications. The Master E Series (1P/1P) comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system that allows continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.9 • Wide input voltage range (110-300 VAC) • Active input power factor correction 0.99 • 50Hz/60Hz frequency converter mode • Eco mode operation for energy saving (ECO) • Programmable power management outlets • Emergency power off function (EPO) • Generator compatible • Charger capacity expansion to 8A for long-run models • SNMP/USB/RS-232 communications • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Maintenance bypass available Rear Panel For 6kVA to 10kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Input circuit breaker 11. Input/Output terminal 12. Output terminal 1 13. Output terminal 2 14. External battery terminal (only available for Long-run model) 15. Utility input terminal 16. Output IEC Socket 1 2 3 4 5 5 6 8 8 7 14 9 10 16 12 13 15 11 PRO806ES/EL PRO810ES/EL 12 Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • Output Isolation Transformer Full Specifications MODELS Phase Capacity PRO810ES/EL PRO806ES/EL Single phase with ground 6000 VA 10000 VA INPUT Nominal Voltage 208/220/230/240 VAC 110-300 VAC at 50% load 176-300 VAC at 100% load Voltage Range Frequency Range 46~54 Hz or 56~64 Hz ≧ 0.99 @ full load Power Factor OUTPUT Output Voltage 200/ 208/ 220/ 230/ 240VAC AC Voltage Regulation (Batt. Mode) ±1% Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Current Crest Ratio 3:1 (max) Harmonic Distortion ≦ 3 % THD (Linear Load), ≦ 6 % THD (Non-linear Load) Transfer Time Zero AC Mode to Batt. Mode Zero Inverter to Bypass Waveform (Batt. Mode) Pure Sinewave EFFICIENCY AC Mode 89% Battery Mode 88% BATTERY Type Standard Model 12 V / 7 Ah 12 V / 9 Ah Numbers Recharge Time (Typical) 20 7 hours recover to 90% capacity Charging Current Charging Voltage Depending on the application Type Numbers Long-Run Model 9 hours recover to 90% capacity 1.0 A (max) 273 VDC ± 1% 18-20 Charging Current 4.0 A (max) Charging Voltage 273 VDC ± 1% INDICATORS UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions LCD Display INDICATORS Battery Mode Sounding every 4 seconds Low Battery Sounding every second Sounding twice every second Overload Fault Continously sounding PHYSICAL Standard Model Long-Run Model 592 x 250 x 576 Dimension (mm) D x W × H Net Weight (kgs) 81 83 Dimension (mm) D × W × H Net Weight (kgs) 592 x 250 x 576 25 27 ENVIRONMENT Operation Humidity 20-90 % RH @ 0- 40°C (Non-condensing) Noise Level Less than 55dBA @ 1 Meter MANAGEMENT Smart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC Optional SNMP Less than 58dB @ 1 Meter Power management from SNMP manager and web browser A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 13 Online UPS Master Series (1P/1P) - 2-in-1 Rack/ Tower Online Master Series 1kVA – 10kVA Small Computer Network Local Area Network (LAN) Work-Stations Servers 19” Rack Mount 0.9 Output Power Factor Master Series (1P/1P) – 2-in-1 Rack/Tower is a single-phase UPS system that employs a true online double-conversion technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance and efficiency to meet the requirements of a mission critical environment. This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need. • True Double-Conversion Online UPS • Output Power factor of 0.9 • User-friendly and easy-shift LCD display • Rack/ Tower design • Programmable power management outlets for 1-3K • 50/60 Hz frequency converter mode • ECO and advanced ECO mode for energy saving • Emergency Power Off Function (EPO) • Hot-swappable battery design for all model • DSP technology applied for 6K and up models • Active input power factor correction 0.99 for 6K and up models • N+X parallel redundancy available for 6K and up models 14 Online UPS Rear Panel For 1kVA to 3kVA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. External battery terminal (only available for Long-run model) 11. Output IEC320-C20 connector 12. Fan 1 7 5 12 6 10 3 9 8 2 4 PRO801RS/RL PRO8015RS/RL PRO802RS/RL 1 7 5 12 10 12 8 3 11 9 6 2 4 PRO803RS/RL For 6kVA to 10kVA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. Battery connection 11. Input terminal 12. Fan 13. Parallel port (only available for parallel model) 14. External maintenance by-pass switch connection 15. Output Terminal 16. Ground 13 9 6 7 14 7 4 12 10 11 16 15 PRO806RS/RL PRO810RS/RL Battery Pack For 1kVA to 3kVA model Capacity Battery Type Battery Number (max) Dimension (DxWxH) mm Net Weight (kg) 1K 1.5K 2K 3K 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 4 pcs 6 pcs 8 pcs 12 pcs 380 x 438 x 88 480 x 438 x 88 17.3 24.8 600 x 438 x 88 29.8 42.5 For 6kVA to 10kVA model Capacity Battery Type Battery Number (max) 6K 10K 12 V / 7 Ah 12 V / 9 Ah 20 pcs 20 pcs Dimension (DxWxH) mm Net Weight (kg) 580 x 438 x 133 57 63 15 Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (communication interface) • Universal Rackmount Slider for installation in rack cabinets • External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA) • Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA) • External Automatic Transfer Switch (ATS) Full Specifications MODELS Phase PRO801RS/ RL Capacity 1000 VA PRO8015RS/ RL PRO802RS/ RL Single phase with ground 1500 VA INPUT Nominal Voltage PRO803RS/ RL 2000 VA 3000 VA 100*/110*/115*/120 /127 VAC or 200/208/220/230/240 VAC Voltage Range 55-150 VAC ± 5% or 110-300 VAC ± 5% Frequency Range 40Hz ~ 70Hz ≧ 0.99 @ Nominal Voltage (100% Load) Power Factor OUTPUT Output Voltage 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC ±1% Voltage Regulation (Batt. Mode) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Synchronized Range) 50 Hz ± 0.5% or 60Hz ± 0.5% Frequency Range (Batt. Mode) 5:1 (max.) Current Crest Ratio ≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear load) Harmonic Distortion (Line Mode) Transfer Time Zero Line Mode to Battery Mode 4 ms Inverter to Bypass Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode 87% 88% 89% Battery Mode 85% 86% 87% ECO Mode 94% 95% 97% BATTERY Battery Type Standard Model Number 12 V / 9 Ah 3 2 Recharge Time (Typical) Charging Current (Max.) Charging Voltage Battery Type Long-Run Model 1.0A 41.1 VDC ± 1% 27.4 VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% Depending on the capacity of external batteries Number Recharge Time (Typical) Charging Current (Max.) Charging Voltage 6 4 Back to 90% capacity in 4 hours 1A / 2A / 4A / 8A 41.1 VDC ± 1% 27.4 VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% INDICATORS Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator LCD Display ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Continously sounding Fault PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H 380x438x88 (2U) Net Weight (kgs) Dimension (mm) D × W × H 12.9 380x438x88 (2U) 17.6 8.6 10.7 Net Weight (kgs) 480x438x88 (2U) 600x438x88 (2U) 20.6 28 600x43x88(2U) 11.3 13.8 480x438x88 (2U) ENVIRONMENT Operation Humidity 20-90 % RH @ 0- 40°C (Non-condensing) Noise Level MANAGEMENT Smart RS-232 / USB Optional SNMP Less than 50dBA @ 1 Meter Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model *All specifications, designs and contents are subject to change without prior notice. 16 Online UPS Full Specifications MODELS Phase PRO806RS/ RL Capacity 6000 VA PRO810RS/ RL Single phase with ground 10000 VA INPUT Nominal Voltage 200/208/220/230/240 VAC Voltage Range 110-300 VAC ± 3% at 50% load; 176-300 VAC ± 3% at 100% load Frequency Range 46~54 Hz or 56~64 Hz ≧ 0.99 @ 100% load Power Factor OUTPUT 200/208/220/230/240 VAC Nominal Voltage AC Voltage Regulation 200/208/220/230/240 VAC ±1% ±1% 46~54 Hz or 56~64 Hz Frequency Range (Synchronized Range) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Frequency Range (Batt. Mode) 3:1 (Max.) Current Crest Ratio ≦ 2 % THD (Linear Load), ≦ 4 % THD (Non-linear Load) Harmonic Distortion ≦ 2 % THD (Linear Load), ≦ 4 % THD (Non-linear Load) 0 ms Line Mode to Battery Mode Transfer Time Battery Mode to Line mode 4 ms Inverter to Bypass Bypass to Inverter Waveform (Batt. Mode) Pure Sinewave EFFICIENCY Line Mode 90% 90% Battery Mode 88% 88% ECO Mode 96% 96% BATTERY Nominal Voltage Standard Model Battery Type Numbers Recharge Time (Typical) 240 VDC 12 V / 7 Ah 12 V / 9 Ah 20 (18-20 pcs adjustable)* 20 (18-20 pcs adjustable)* Back to 90% capacity in 7 hours Back to 90% capacity in 9 hours 1.0 A 273 VDC (based on battery numbers at 20 pcs) Charging Current (max.) Float Charging Voltage Depending on the application Battery Type and Numbers Long-Run Model Charging Current (max.) 4.0 A Float Charging Voltage 273 VDC (based on battery numbers at 20 pcs) INDICATORS Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator LCD Display ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continously sounding PHYSICAL UPS Unit: 580 x 438 x 133 (3U) Battery Pack: 580 x 438 x133 (3U) UPS Unit: 668 x 438 x 133 (3U) Battery Pack: 580 x 438 x133 (3U) Net Weight (kgs) UPS Unit: 20 Battery Pack: 57 UPS Unit: 23.5 Battery Pack: 63 Dimension (mm) D x W × H 580 x 438 x 133 668 x 438 x 133 20 23.5 Dimension (mm) D x W × H Standard Model Long-Run Model Net Weight (kgs) ENVIRONMENT Operation Humidity Noise Level MANAGEMENT Smart RS-232 / USB Optional SNMP 0-95 % RH @ 0- 40°C (Non-condensing) Less than 58dBA @ 1 Meter Less than 60dBA @ 1 Meter Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model *All specifications, designs and contents are subject to change without prior notice. 17 Online UPS True Double-conversion Online UPS Output Power Factor 0.9 A true double conversion UPS system will provide clean and high quality electrical power to fully protect mission critical systems such as sensitive networks, small computer centers, servers, telecom applications and industrial applications. Master (1P/1P) 2-in-1 rack/Tower Series is a high-density UPS system with an output power factor of 0.9. With this high power factor, the Master series is able to provide higher performance to critical applications. Programmable Power Management Outlets User-friendly LCD Display The front panel digital display comes with an auto-rotation feature that caters to your installation preference; either vertically or wall mounted. The programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices. Programmable Outlets (P1) - connect to non-critical devices Rack Display Tower Display ECO and Advanced ECO Mode for Energy Saving Rack / Tower Design This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket. It allows the UPS to operate in high efficiency of up to 97% during energy saving ECO mode and 98% in operation mode. In the event of an electrical AC failure, the inverter will automatically step-in and provide electrical supply to the connected systems. Emergency Power Off Function (EPO) This feature provides adequate protection for the user and the equipment against hazards such as fire break-out or other emergencies. 19” Rack-mounting Floor-standing Tower High Output Crest Ratio The Master (1P/1P) 2-in-1 Rack/Tower Series is designed with a high output crest ratio of 5:1 that allows the device to be extremely compatible with equipment such as compressors, generators and motors. Hot-swapping Battery Design The hot-swapping battery feature helps to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down. Output Voltage Regulation (tolerance +/- 1%) The Master (1P/1P) 2-in-1 rack / Tower Series is able to produce extremely stable and clean electrical power with its high efficiency output voltage regulator. This regulator is able to achieve a tolerance of +/- 1%, making it extremely compatible even with sensitive power supplies. Long Battery Runtime Models Available Our Long Battery Runtime Models offers the flexibility to add-on additional external batteries to provide a longer back-up time. 18 Online UPS Master Series (3P/1P) - Tower Online Master Series 10kVA – 30kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Master Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.8 • Wide Input Voltage Range (305-478VAC for 3-Phase/ 100-300VAC for 1-Phase) • Supports Auto Phase Adaptation • Active power factor correction in all phases • Built-in phase auto adapt function simplifies wire installation • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving Rear Panel • Programmable power management outlets • Emergency power off function (EPO) • Generator compatible • SNMP/USB+RS-232 multiple communications (SNMP is optional) • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Maintenance bypass available • Optional N+X parallel redundancy • Optional isolation transformer available For 10kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. External battery connector (Only available for Long-run Model) 1 2 3 4 8 5 6 5 7 14 8 9 10 11 12 13 PRO83110S/L 19 Online UPS For 15kVA to 30kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. Output Terminal: Connect to mission-critical loads 15. Programmable Output terminal: Connect to non-critical loads 16. External battery terminal (only available for Long-run model) 17. Utility input terminal 18. Grounding terminal (only available for parallel system) For 10K model 1 2 3 4 5 8 4 8 5 6 7 5 9 7 5 7 8 1 2 3 6 10 11 8 7 9 10 11 18 PRO83115L PRO83120L PRO83115S PRO83120S PRO83130S/L PRO83130L For 15K & 30K model 18 14 15 17 14 15 16 17 Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer (Available only for Long-run Model) 20 Online UPS Full Specifications MODELS PRO83110S/ L PRO83115S/ L Phase PRO83120S/ L PRO83130S/ L 3-phase in / 1-phase out Capacity 10 kVA 15 kVA 20 kVA 30kVA INPUT Nominal Voltage 3 x 400VAC (3Ph+N) Voltage Range 305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load Frequency Range 46~54Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% Load < 6% @ 100% load THDi OUTPUT Output Voltage 208/220/230/240VAC Voltage Regulation (Batt. Mode) ±1% 46~54Hz or 56~64Hz Frequency Range (Synchronized Range) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Frequency Range (Batt. Mode) 3:1 Current Crest Ratio ≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) Harmonic Distortion Transfer Time AC Mode to Batt. Mode Zero Inverter to Bypass Zero Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode 89% Battery Mode 86% 90% 88% 87% 89% BATTERY Battery Type Numbers Standard Model 12 V / 9 Ah 20 pcs (18 - 20 pcs adjustable)* 20 pcs (18 - 20 pcs adjustable)* x 2 strings Recharge Time (Typical) Charging Current (Max.) Back to 90% capacity in 9 hours 1A 2A Charging Voltage Depending on the application Depending on the application Numbers Charging Current (Max.) 2A 273 VDC ± 1% (Based on 20pcs batteries) Battery Type Long-Run Model 20pcs(18-20pcs adjustable)*x3 strings 4A 8A Charging Voltage 12 A 273 VDC ± 1% (Based on 20pcs batteries) INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continously sounding PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) 592 x 250 x 576 815 × 250 × 826 83 164 234 592 ×250 × 576 592 x 250 x 576 815 × 250 × 826 28 40 64 815 × 300 × 1000 ENVIRONMENT Humidity Noise Level 0-95 % RH @ 0- 40°C (Non-condensing) Less than 58dB @ 1 Meter Less than 60dB @1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 21 Online UPS 0.9 Master Series (3P/1P) - Tower Output Power Factor Online Master E Series 10kVA – 30kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Master E Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. The E-Series provides better output power factor of up to 0.9; offering high performance and efficiency for your critical applications. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.9 • Wide input voltage range (110-300 VAC) • Active power factor correction in all phases • Built-in phase auto adapt function simplifies wire installation • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving • Programmable power management outlets • Emergency power off function (EPO) • Generator compatible • SNMP+USB+RS-232 multiple communications • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Maintenance bypass available • Optional N+X parallel redundancy • Optional isolation transformer available Rear Panel For 10kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. External battery connector (Only available for Long-run Model) 1 2 3 4 8 5 6 5 7 14 8 9 10 11 12 13 PRO83110ES/EL PRO83110ELI 22 Online UPS For 15kVA to 30kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. Output Terminal: Connect to mission-critical loads 15. Programmable Output terminal: Connect to non-critical loads 16. External battery terminal (only available for Long-run model) 17. Utility input terminal 18. Grounding terminal (only available for parallel system) For 10K model 1 2 3 4 5 8 4 8 5 6 7 5 9 7 5 7 8 1 2 3 6 10 11 8 7 9 10 11 18 PRO83115ES/ EL PRO83120ES/ EL PRO83120ELI PRO83130ES/ EL For 15K & 30K model 18 14 15 17 14 15 16 17 Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer (Available only for PRO83110ELI & PRO83120ELI) 23 Online UPS Full Specifications MODELS PRO83110ES/ EL PRO83110ELI PRO83115ES/ EL PRO83120ES/ EL Phase PRO83120ELI PRO83130ES/ EL 20kVA 30kVA 3-phase in / 1-phase out Capacity 10kVA 10kVA 20kVA 15kVA INPUT Nominal Voltage 3 x 400VAC (3Ph+N) Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46 ~ 54Hz or 56 ~ 64Hz ≧ 0.99 @ 100% load Power Factor < 6% @ 100% load THDi OUTPUT 208/220/230/ 240VAC Output Voltage 104/110/115/ 120VAC or 208/ 220/230/240VAC Voltage Regulation (Batt. Mode) 208/220/230/240VAC 208/220/230/ 240VAC ±1% 46~54Hz or 56~64Hz Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 3.1 Current Crest Ratio ≦2 % THD ≦2 % THD (Linear Load) (Linear Load) ≦5 % THD ≦6% THD (Non-linear Load) (Non-linear Load) Harmonic Distortion Transfer Time 104/110/115/ 120VAC or 208/ 220/230/240VAC ≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) ≦2 % THD ≦2 % THD (Linear Load) (Linear Load) ≦7% THD ≦5% THD (Non-linear Load) (Non-linear Load) Zero AC Mode to Batt. Mode Zero Inverter to Bypass Waveform (Batt. Mode) Pure Sinewave EFFICIENCY AC Mode 91% 85% Battery Mode 86% 83% 91% 88% 87% 87% 91% 83% 88% BATTERY Battery Type Numbers Standard Model 12 V / 9 Ah 20 pcs (18 - 20 pcs adjustable)* Recharge Time (Typical) 20 pcs (18 - 20 pcs adjustable)* x 2 strings Back to 90% capacity in 9 hours Charging Current (Max.) Charging Voltage 1A Back to 90% capacity in 9 hours 2A 273 VDC ± 1% (Based on 20pcs batteries) Battery Type 2A Depending on the application Numbers Long-Run Model Not Applicable 20pcs(18-20pcs adjustable) x3 strings Depending on the application 4A Charging Current (Max.) 8A Charging Voltage 12A 273 VDC ± 1% (Based on 20pcs batteries) INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding twice every second Overload Sounding twice every second Continously sounding Fault PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) 592 x 250 x 576 592 x 250 x 826 815 × 250 × 826 83 144 164 592 ×250 × 576 592 x 250 x 826 592 x 250 x 576 28 91 40 Not Applicable 815 × 300 × 1000 234 815 × 250 × 826 141 64 ENVIRONMENT Humidity Noise Level 0 - 95% RH @ 0 - 40°C (Non-condensing) Less than 58dB @ 1 Meter Less than 60dB @ 1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 24 Online UPS Master Series (3P/1P) - Rack Mount Online Master Series 10kVA – 20kVA Local Area Telecommunication Network Devices (LAN) Data Centre 19” Rack Mount Storage PLCS Emergency Alarm Devices Master Series (3P/1P) – Rack three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) – Rack UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.8 • Wide input voltage range (110-300 VAC) • Active power factor correction in all phases • Built-in phase auto adapt function simplifies wire installation • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving • Emergency power off function (EPO) • Generator compatible • SNMP/USB+RS-232 multiple communications (SNMP is optional) • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Optional N+X parallel redundancy Rear Panel For 10kVA to 20kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Parallel port (only available for parallel model) 5. Intelligent slot 6. Fan 7. External maintenance by-pass switch connection 8. Input circuit breaker 9. Input/Output terminal 10. Output terminal 11. Battery terminal 12. Input terminal 4 4 5 11 4 7 8 1 6 6 2 3 9 12 10 PRO83110RS/RL 5 7 1 6 9 6 12 10 2 3 4 8 6 6 4 4 11 PRO83115RS/ RL PRO83120RS/RL 25 Online UPS Options • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Universal Rackmount Slider for installation in rack cabinets • External Maintenance Bypass Switch (Only available with 10kVA model) Full Specifications MODELS PRO83110RS/ RL PRO83115RS/ RL Phase PRO83120RS/ RL 3-phase in / 1-phase out 10kVA Capacity 20kVA 15kVA INPUT Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz ≧ 0.99 @ 100% Load Power Factor < 6% @ 100% Load THDi OUTPUT Output Voltage 208/220/230/240VAC AC Voltage Regulation (Batt. Mode) ±1% 46~54Hz or 56~64Hz Frequency Range (Synchronized Range) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Frequency Range (Batt. Mode) Current Crest Ratio 3:1 Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) Transfer Time Zero AC Mode to Batt. Mode Zero Inverter to Bypass Pure Sinewave Waveform (Batt. Mode) EFFICIENCY 89% AC Mode Battery Mode 86% 88% 87% BATTERY Battery Type Standard Model Numbers 12 V / 9 Ah 20 (18 - 20 adjustable) 20 pcs x 2 strings (18 - 20 adjustable) Recharge Time (Typical) Charging Current (Max.) Back to 90% capacity in 9 hours 1A 2A 273 VDC ± 1% (based on battery numbers at 20 pcs) Charging Voltage Battery Type Long-Run Model Depending on the capacity of external batteries Numbers Charging Current (Max.) 4A Charging Voltage 273 VDC ± 1% (based on battery numbers at 20 pcs) INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions ALARM Battery Mode Sounding every 4 seconds Sounding every second Low Battery Sounding twice every second Overload Fault Continously sounding PHYSICAL Standard Model Dimension (mm) D x W × H Net Weight (kgs) Long-Run Model Dimension (mm) D × W × H Net Weight (kgs) UPS Unit: 668 x 438 x 133 (3U) Battery Pack: 580 x 438 x 133 (3U) UPS Unit: 668 x 438 x 266 (6U) BatteryPack: 580 x 438 x 133 (3U) x 2PCS UPS unit: 22 Battery pack: 63 UPS unit: 45 Battery pack: 63 x 2PCS 668 x 438 x 133 (3U) 668 x 438 x 266 (6U) 22 45 ENVIRONMENT Operation Humidity Noise Level 0-95 % RH @ 0- 40°C (Non-condensing) Less than 60dB @ 1 Meter Less than 65dB @ 1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model *All specifications, designs and contents are subject to change without prior notice. 26 Online UPS Master Series (3P/3P) - Tower Online Master Series 10kVA – 30kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Master Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.8 • Active power factor correction in all phases • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving • Accepts dual-mains inputs (only available for dual input unit) • Emergency power off function (EPO) • Generator compatible • SNMP/USB+RS-232 multiple communications (SNMP is optional) • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Maintenance bypass available • Optional N+X parallel redundancy • Optional isolation transformer offers full isolation and complete common mode noise rejection Rear Panel 1 2 3 4 6 8 For 10kVA to 30kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker 12. Input/Output terminal 13. External battery terminal (only available for Long-run model) 5 7 8 9 7 11 10 13 12 PRO83310S/L PRO83320S/L PRO83330S/L 27 Online UPS Options • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Full Specifications MODELS PRO83310S/ L PRO83315S/ L Phase PRO83320S/ L 10kVA Capacity 15kVA INPUT Nominal Voltage 30kVA 20kVA 3 x 400 VAC (3Ph+N) Input Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% Load OUTPUT Output Voltage 3 x 400 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1% Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Current Crest Ratio 3:1 (Max.) Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) Transfer Time PRO83330S/ L 3-phase in / 3-phase out Zero AC Mode to Batt. Mode Zero Inverter to Bypass Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode Battery Mode 89% 88% 86% 90% 89% 87% BATTERY Battery Type Numbers Standard Model 12 V / 9 Ah 20 pcs (18 - 20 adjustable)* 20 pcs x 2 strings (18 - 20 adjustable)* Recharge Time (Typical) Charging Current (Max.) Back to 90% capacity in 9 hours 2A 1A 4A 273 VDC ± 1% Charging Voltage Battery Type Long-Run Model 20pcs x 3 strings (18-20 adjustable)* Depending on the capacity of external batteries Numbers 4A Charging Current (Max.) 12A 273 VDC ± 1% Charging Voltage INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault ALARM Battery Mode Sounding every 4 seconds Sounding every second Low Battery Overload Sounding twice every second Fault Continously sounding PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) 815 x 250 x 826 109 Dimension (mm) D × W × H Net Weight (kgs) 815 x 300 x 1000 164 592 x 250 x 826 38 233.5 815 x 250 x 826 40 64 ENVIRONMENT Humidity Noise Level 0-95 % RH @ 0- 40°C (Non-condensing) Less than 60dB @ 1 Meter Less than 65dB @ 1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 28 Online UPS 0.9 Master Series (3P/3P) - Tower Output Power Factor Online Master E Series 10kVA – 30kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Master E Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. The Master E Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • DSP technology guarantees high performance • Output power factor 0.9 • Active power factor correction in all phases • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving (ECO) • Accepts dual-mains inputs • Emergency power off function (EPO) • Generator compatible • SNMP+USB+RS-232 multiple communications • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Maintenance bypass available • Optional N+X parallel redundancy Rear Panel 1 2 3 4 6 For 10kVA to 30kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker 12. Input/Output terminal 13. External battery terminal (only available for Long-run model) 5 8 7 8 9 7 11 10 13 12 PRO83310ES/EL PRO83320ES/EL PRO83330ES/EL 29 Online UPS Options • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Full Specifications MODELS PRO83310ES/ EL PRO83315ES/ EL Phase PRO83320ES/ EL 10kVA Capacity 15kVA INPUT Nominal Voltage 30kVA 20kVA 3 x 400 VAC (3Ph+N) Input Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% Load OUTPUT Output Voltage 3 x 400 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1% Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Current Crest Ratio 3:1 (Max.) Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) Transfer Time PRO83330ES/ EL 3-phase in / 3-phase out Zero AC Mode to Batt. Mode Zero Inverter to Bypass Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode Battery Mode 89% 88% 86% 90% 89% 87% BATTERY Battery Type Numbers Standard Model 12 V / 9 Ah 20 pcs (18 - 20 adjustable)* 20 pcs x 2 strings (18 - 20 adjustable)* Recharge Time (Typical) Charging Current (Max.) Back to 90% capacity in 9 hours 2A 1A Charging Voltage 4A 273 VDC ± 1% Battery Type Long-Run Model 20pcs x 3 strings (18-20 adjustable)* Depending on the capacity of external batteries Numbers Charging Current (Max.) 4A Charging Voltage 12A 273 VDC ± 1% INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Continously sounding Fault PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) 815 x 250 x 826 109 Dimension (mm) D × W × H Net Weight (kgs) 815 x 300 x 1000 164 592 x 250 x 826 38 233.5 815 x 250 x 826 40 64 ENVIRONMENT Humidity Noise Level 0-95 % RH @ 0- 40°C (Non-condensing) Less than 60dB @ 1 Meter Less than 65dB @ 1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 30 Online UPS Power Series Online Power Series 15kVA – 120kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Power Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB). Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallel redundant system that allows four UPS models to operate in parallel. An option of an additional isolation transformer is also available to suit your requirements. The Power series is available in models ranging from 15kVA to 120kVA. • Online double conversion technology with DSP control • Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low harmonic distortion • Very low input current distortion (THDi < 1%) • Input power factor 0.99 at 10% load • Output efficiency up to 95% • Space-saving compact design • Front access makes maintenance and replacement easily • Highly flexibility in single phase/three-phase set-ups • Control designed to withstand all kinds of loads • Parallel redundant operation with up to 4 units • Variety of communication options available • Over 60% mateirals recyclable • Remaining backup time calculation • 5.7" graphic LCD panel design with multiple languates for easy-configuration • Optional touch panel design for 5.7" LCD 1 Rear Panel (Internal) For 15kVA to 80kVA model 1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 9. System Terminal 10. Parallel port (only available for parallel model) 3 1 3 2 10 10 2 3 10 1 2 4 4 4 5 6 7 8 5 6 5 6 7 7 8 8 9 9 9 PRO73315S/SI PRO73320S/SI PRO73330S/SI PRO73340S/SI PRO73360S/SI PRO73380S/SI 31 Online UPS 1 For 100kVA to 120kVA model 2 3 1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 9. System Terminal 10. Parallel port (only available for parallel model) 10 4 5 6 7 8 9 PRO733100S PRO733120S Full Specifications MODELS PRO73315S/ SI PRO73320S/ SI PRO73330S/ SI PRO73340S/ SI PRO73360S/ SI PRO73380S/ SI Capacity 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA INPUT Nominal Voltage 3 x 400V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency 50/60 Hz ± 5 % Total Harmonic Distortion (THDi) < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load High overload: PFC Limit (discharging batteries) Current Limitation 1.0 Power Factor INVERTER Nominal Voltage 3 x 400V (3Ph + N) Precision Frequency Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) 50/60 Hz synchronised ±4 % With mains absent ±0.05% ±10 Hz/s Max. Synchronisation Speed Pure Sinewave Waveform <0.5% (Linear Load) ; <1.5% (Non-linear Load) Total Harmonic Distortion (THDv) Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) 10 ms. at 98 % of the static value Dynamic Recovery Time 125% for 10 min., 150% for 60 s Admissible Overload 3.4 : 1 Admissible Crest Factor 3.2 :1 2.8 : 1 0.7 inductive to 0.7 capacitive Admissible Power Factor <1% Imbalance Output Voltage @ 100% Unbalanced Load High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit Current Limit STATIC BYPASS Solid state Type 3x400V (3Ph + N) Voltage Frequency 50/60 Hz Microprocessor control Activation Criterion Zero Transfer Time 400% for 10 sec. Admissible Overload Immediate, for overloads above 150% Transfer to Bypass Automatic after alarm clear Retransfer MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) Frequency 50/60 Hz Overall Efficiency (Line mode) 90.5% 91% 92% 92.5% 12V 4.5Ah 12V 9Ah 12V 12Ah 12V 18Ah 10 9 8 7 93% 94% BATTERY Built-in Battery Type (2x31) Back-up Time (minutes) Max. Charging Current 23.5 A Not Applicable 47 A 70.5 A PHYSICAL Dimensions, D x W x H(mm) 700 x 450 x 1100 Net Weight (W/O batteries) (Kg) Net Weight (w/built-in batteries) (Kg) 805 x 590 x 1320 110 280 180 300 430 210 565 If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 230 Not Applicable 32 Online UPS MODELS PRO733100S PRO733120S Capacity 100kVA 120kVA INPUT Nominal Voltage 3 x 400V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency 50/60 Hz ± 5 % < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load Total Harmonic Distortion (THDi) High overload: PFC Limit (discharging batteries) Current Limitation 1.0 Power Factor INVERTER Nominal Voltage 3 x 400V (3Ph + N) Precision Frequency Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) 50/60 Hz synchronised ±4 % With mains absent ±0.05% ±10 Hz/s Max. Synchronisation Speed Pure Sinewave Waveform <0.5% (Linear Load) ; <1.5% (Non-linear Load) Total Harmonic Distortion (THDv) 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Phase Displacement 10 ms. at 98 % of the static value Dynamic Recovery Time 125% for 10 min., 150% for 60 s Admissible Overload Admissible Crest Factor 3.2 :1 Admissible Power Factor 0.7 inductive to 0.7 capacitive <1% Imbalance Output Voltage @ 100% Unbalanced Load High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit Current Limit STATIC BYPASS Solid state Type 3x400V (3Ph + N) Voltage Frequency 50/60 Hz Microprocessor control Activation Criterion Zero Transfer Time 400% for 10 sec. Admissible Overload Immediate, for overloads above 150% Transfer to Bypass Automatic after alarm clear Retransfer MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) Frequency 50/60 Hz Overall Efficiency (Line mode) 93% 93.3% BATTERY Max. Charging Current 188 A PHYSICAL Dimensions, D x W x H(mm) Net Weight (W/O batteries) (Kg) Net Weight (w/built-in batteries) (Kg) 805 x 590 x 1320 255 Not Applicable Options • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 33 Online UPS The Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power Series is available in capacities ranging from 15 to 120kVA. Online Double Conversion Technology with DSP Control The Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves the performance and efficiency of the UPS. Input Power Factor 0.99 At 10% Load Lower power losses would result in reduced consumption, lower operation and maintenance costs. INPUT POWER FACTOR 1,20 1,00 0,80 PFin The Most Versatile Solution For Power Protection 0,60 0,40 0,20 0,00 0% 25% 50% LOAD Output Efficiency of up to 95% Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses. SERIES TIPICAL EFFICIENCY 100% Advanced Control with Adaptive Feed Forward Cancellation (AFC) Technology By cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity. Low Input Current Distortion (THDi < 1%) AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network. EFFICIENCY 75% 50% 25% 0% 0% 25% 50% LOAD Small Form Factor Utilizes a transformerless technology allows the design of the UPS to be lighter and smaller. 34 Online UPS An important consideration has been given during the UPS design phase to create a system that allows users to access the unit’s electronic cards and power components with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities. Variety Of Available Communications And Option The UPS has provided the following standard communication selections: • Relay interface • RS-232/485 port • 1 × SNMP slot • Modbus RTU / SEC protocol • 2 × connectors for parallel connection Made of 60% Recyclable Materials Versatile Single-Phase / Three-Phase set-ups This highly versatile UPS is designed with different types of setting-up options; • Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I) When it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials. Back-up Time indicator Control Components are designed to with stand all kinds of loads In the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear, high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of environment. With the use of simple algorithms, an estimated remaining back-up time can be calculated and indications will be reflected on a LCD panel. 5.7” Multiple Languages Graphical LCD Display Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. N+1 Redundancy A parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other. 35 Online UPS Power Series Online Power E Series 10kVA – 120kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PROLiNK UPS Power E Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Power E Series give excellent output leading power factor up to 0.9 leading for 100% load. Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB). Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallel redundant system that allows four UPS models to operate in parallel. An option of an additional isolation transformer is also available to suit your requirements. The Power series is available in models ranging from 10kVA to 120kVA. • Online double conversion technology with DSP control • Output power factor 0.9 • Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low • Very low input current distortion (THDi < 1%) • Input power factor 0.99 at 10% load • Output efficiency up to 95% • Space-saving compact design • Over 60% materials recyclable • Remaining backup time calculation • Remaining backup time calculation • Front access makes maintenance and replacement easily • Highly flexibility in single phase/ three-phase set-ups • Parallel redundant operation with up to 4 units • Variety of communications and options available • Flexible battery type configuration by request (only available for Taurus Pro 400V models) • Long-run models available for 400V 10KVA-40KVA and 208V 7.5KVA-20KVA 1 Rear Panel (Internal) 1 For 10kVA to 80kVA model 3 10 1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 9. System Terminal 10. Parallel port (only available for parallel model) 1 2 3 3 10 10 2 2 4 4 4 5 6 7 8 5 6 5 6 7 7 8 8 9 9 9 PRO73310ES PRO73315ES PRO73320ES PRO73330ES PRO73340ES PRO73360ES PRO73380ES 36 Online UPS 1 For 100kVA to 120kVA model 2 3 10 1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 9. System Terminal 10. Parallel port (only available for parallel model) 4 5 6 7 8 9 PRO733100ES PRO733120ES Full Specifications MODELS PRO73310ES PRO73315ES PRO73320ES PRO73330ES PRO73340ES PRO73360ES PRO73380ES 60kVA 80kVA 3-phase in / 3-phase out Phase 10kVA Capacity 15kVA 20kVA 30kVA INPUT Nominal Voltage 40kVA 3 x 400V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency 50 / 60 Hz ±5 % Current Limitation High overload: PFC Limit (discharging batteries) 1.0 Power Factor < 1.5% @ 100% load; < 2.5% @ 50% load; < 6.0% @ 10% load Total Harmonic Distortion (THDi) < 1.0% @ 100% load; < 2.0% @ 50% load; < 5.0% @ 10% load INVERTER Nominal Voltage 3 x 400V (3Ph + N) Precision Frequency Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) 50/60 Hz synchronised ±4 % With mains absent ±0.05% Max. Synchronisation Speed ±10 Hz/s Waveform Pure Sinewave Total Harmonic Distortion (THDv) < 0.5% (Linear Load) ; < 1.5% (Non-linear Load) Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 10 ms. at 98 % of the static value Admissible Overload Admissible Crest Factor Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s Admissible Power Factor 0.7 inductive to 0.7 capacitive Imbalance Output Voltage @ 100%Unbalanced Load <1% 3.4 : 1 3.2 :1 2.8 : 1 High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit Current Limit STATIC BYPASS Type Solid state Voltage 3x400V (3Ph + N) 50/60 Hz Frequency Microprocessor control Activation Criterion Zero Transfer Time 400% for 10 sec. Admissible Overload Immediate, for overloads above 150% Transfer to Bypass Automatic after alarm clear Retransfer MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) 50/60 Hz Frequency Overall Efficiency (Line mode) 90% 90.5% 91% 92% 92.5% 12V 4.5Ah 12V 4.5Ah 12V 7Ah 12V 9Ah 12V 12Ah 5 3 5 93% 94% BATTERY Built-in Battery Type (2x31) Back-up Time (minutes) Max. Charging Current 3 Not Applicable 3 23.5 A 47 A 70.5 A PHYSICAL Dimension (mm) D x W x H 770 x 450 x 1100 805 x 590 x 1320 Net Weight (without batteries) (kgs) 78 86 94 110 122 Net Weight (w/built-in batteries) (kgs) 178 186 249 290 357 If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 162 231 Not Applicable 37 Online UPS MODELS PRO733100ES PRO733120ES 3-phase in / 3-phase out Phase 100kVA Capacity 120kVA INPUT Nominal Voltage 3 x 400V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency 50 / 60 Hz ±5 % Current Limitation High overload: PFC Limit (discharging batteries) 1.0 Power Factor < 1.5% @ 100% load; < 2.0% @ 50% load; < 6.0% @ 10% load Total Harmonic Distortion (THDi) INVERTER Nominal Voltage 3 x 400V (3Ph + N) Precision Frequency Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) 50/60 Hz synchronised ±4 % With mains absent ±0.05% Max. Synchronisation Speed ±10 Hz/s Waveform Pure Sinewave Total Harmonic Distortion (THDv) Phase Displacement < 0.5% (Linear Load) ; < 1.5% (Non-linear Load) 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 10 ms. at 98 % of the static value Admissible Overload Admissible Crest Factor Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s Admissible Power Factor 0.7 inductive to 0.7 capacitive Imbalance Output Voltage @ 100%Unbalanced Load <1% 3.2 :1 High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit Current Limit STATIC BYPASS Type Solid state Voltage 3x400V (3Ph + N) 50/60 Hz Frequency Microprocessor control Activation Criterion Zero Transfer Time 400% for 10 sec. Admissible Overload Immediate, for overloads above 150% Transfer to Bypass Automatic after alarm clear Retransfer MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) Frequency 50/60 Hz Overall Efficiency (Line mode) 93% 93.3% 70.5 A 188 A BATTERY Max. Charging Current PHYSICAL Dimension (mm) D x W x H Net Weight (without batteries) (kgs) Net Weight (w/built-in batteries) (kgs) 805 x 590 x 1320 255 Not Applicable Options • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 38 Online UPS The Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power Series is available in capacities ranging from 15 to 120kVA. Online Double Conversion Technology with DSP Control The Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves the performance and efficiency of the UPS. Input Power Factor 0.99 At 10% Load Lower power losses would result in reduced consumption, lower operation and maintenance costs. INPUT POWER FACTOR 1,20 1,00 0,80 PFin The Most Versatile Solution For Power Protection 0,60 0,40 0,20 0,00 0% 25% 50% LOAD Output Efficiency of up to 95% Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses. SERIES TIPICAL EFFICIENCY 100% Advanced Control with Adaptive Feed Forward Cancellation (AFC) Technology By cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity. Low Input Current Distortion (THDi < 1%) AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network. EFFICIENCY 75% 50% 25% 0% 0% 25% 50% LOAD Small Form Factor Utilizes a transformerless technology allows the design of the UPS to be lighter and smaller. Output Power Factor Nowadays IT installation requirements are driving to power sources able to supply loads with leading power without affecting the power capability. Power E Series UPS are able to supply full power without any derating for all loads from 0.9 lagging to 0.9 leading. This unique characteristic avoids any UPS over sizing in case of unity or leading power factor as for the loads. 39 Online UPS Front Access concept An important consideration has been given during the UPS design phase to create a system that allows users to access the unit’s electronic cards and power components with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities. Variety Of Available Communications And Option The UPS has provided the following standard communication selections: • Relay interface • RS-232/485 port • 1 × SNMP slot • Modbus RTU / SEC protocol • 2 × connectors for parallel connection Made of 60% Recyclable Materials Versatile Single-Phase / Three-Phase set-ups This highly versatile UPS is designed with different types of setting-up options; • Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I) When it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials. Back-up Time indicator Control Components are designed to with stand all kinds of loads In the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear, high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of environment. With the use of simple algorithms, an estimated remaining back-up time can be calculated and indications will be reflected on a LCD panel. 5.7” Multiple Languages Graphical LCD Display Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. N+1 Redundancy A parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other. 40 Online UPS PPM Series PROLiNK Power Modular (PPM) UPS System Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PROLiNK PPM Series modular three-phase input / three-phase output online double conversion UPS takes scalability to a whole new level. Based on a scalable design, the PPM comes with a wide range of capacity, ranging from as low as 30kVA to as high as 210kVA. The PPM series is designed with a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other. This unit provides an ideal protection for data centers, telecommunication facilities and other critical applications. Up to seven 30kVA modules can be fitted into a standard cabinet to simplify maintenance and replacement activities. The PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery. • High efficiency online double conversion technology • High scalability • Unity output power factor • Modular design lowers MTTR • N+1 or N+X parallel redundancy for power guarantee • Ease of installation and maintenance • Flexible battery configuration adapts different applications • Adjustable charging current • High overload capability • Graphic 5.7” LCD design for easy management High Efficiency Online Double Conversion Technology High Scalability PROLiNK PPM is designed with the latest online double conversion technology that provides a high efficiency rating of 96%. With such a high efficiency rating, the PPM can save you hundreds of dollars each year. Based on a scalable design, the PPM Series simplifies future expansion by making UPS units easily upgradable. This architecture allows you to meet power demands by adding additional modules vertically in a single rack enclosure. Unity Output Power Factor Modular Design Lowers MTTR With a unity output factor (kVA = kW), the PROLiNK PPM UPS system is 100% compatible with today's high power factor loads. It is able to meet the latest server requirements, giving the best value for your IT investments. The modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery. 41 Online UPS N+X Parallel Redundancy Ease Of Installation and Maintenance The PPM series is designed with a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other. With a built-in maintenance bypass feature, the UPS is able to deliver continuous power to the critical load during maintenance. Better yet, the PPS comes with a front access concept to facilitate installation. Adjustable Charging Current PROLiNK PPM comes with a maximum charging current of up to 8A for each individual module. The charging current can be adjusted based on the necessary requirement. High Overload Capability PROLiNK PPM supports 110% overload for 60 minutes, 120% for 10 minutes and 150% for 1 minute. 5.7” LCD Graphic Mimic Panel A multilingual 5.7" graphic LCD screen is integrated as part of the design to provide users with visual information and advanced control abilities. PPM90 The PROLiNK PPM90 is a compact stand alone UPS system that provides the best backup solution for small and medium loads. This unit comes with a standard EIA height of 30U and is able to fit capacities ranging from 30kVA to 90kVA in the same cabinet. With features such as N+1 redundancy and the capability for future expansion, the PROLiNK PPM90 is definitely able to make your backup experience an absolute cinch. No. Of Module Capacity 1 30kVA 2 60kVA 3 90kVA Dimension 600 x 1100 x 1485 (30U) mm Exterior Interior Exterior Interior PPM210 The PROLiNK PPM210 is a standalone UPS system that comes with a standard EIA height of 42U. This unit is able to fit 7 x 30kVA modular redundancy in the same cabinet. Even better, the PPM210 has the capability to manage future capacity expansion of up to 210kVA, making the PPM210 the best backup solution for greater loads. No. Of Module Capacity 1 30kVA 2 60kVA 3 90kVA 4 120kVA 5 150kVA 6 180kVA 7 210kVA Dimension 600 x 1100 x 2030 (42U) mm 42 Online UPS Full Specifications MODELS PPM30 PPM60 PPM90 Phase PPM120 PPM150 PPM180 PPM210 3-phase in/3-phase out Total Capacity* UPS Power Modules 30KW 60KW 90KW 120KW 150KW 180KW 210KW 1 2 3 4 5 6 7 Topology True Double-Conversion Online INPUT Nominal Voltage Voltage Range 3 x 400 VAC (3Ph+N) 305 ~ 477 Vac @Full load, 208 ~ 477 Vac @ <70% load 50/60Hz (auto-selectable) Nominal Frequency 40Hz ~70Hz Frequency Range > 0.99 @ 100% Load , >0.98 @ 50% Load Power Factor < 3% @ 100% load Harmonic Distortion (THDi) OUTPUT Nominal Voltage Voltage Regulation (Steady state) 3 x 400 VAC (3Ph+N) ≦± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load) ≦± 5% Typical Voltage Regulation (Transient) Nominal Frequency 50/60Hz Frequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz Overload Capability 1 hour for 110%, 10 mins for 120%, ; 1 min for 150%, 200ms for >150% Harmonic Distortion ≦1.5% THD (Linear Load) ; ≦ 4% THD (Non-linear Load) Efficiency >94.5% BATTERY / CHARGER Nominal Voltage +/- 216V (12V x 36 pcs) Maximum Voltage +/- 240V (12V x 40 pcs) Minimum Voltage +/- 192V (12V x 32 pcs) Float Charging Voltage 2.25V / Cell Boost Charging Voltage 2.35V / Cell Temperature Compensation Yes Maximum Charging Current 8A (User-adjustable) PHYSICAL Medium Size (mm) D x W x H Full Size (mm) D x W x H 1100 x 600 x 1485 (30U) Not Applicable 1100 x 600 x 2030 (42U) ENVIRONMENT Operation Temperature Relative Humidity 0 ~ 40°C 0 ~ 95% non-condensing Altitude <1000m for Nominal power IP Class IP 20 MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser STANDARDS Safety EMC IEC/EN 60950-1; IEC/EN 62040-1 IEC/EN 62040-2 Category C3 When temperature above 30°C, the system output power factory will become 0.8 One power module provides 30kW power capacity. One battery module contains 10 pcs of 12V7Ah, 12V9Ah or 12V10Ah (subject to requirement) Valve Regulated Lead Acid batteries. All specifications, designs and contents are subjected to changes without prior notice. 43 Online UPS PRO-R Series 1U Online UPS 1000VA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PROLiNK PRO-R is a transformerless Online UPS that is designed with a small footprint. Despite being thinner and lighter, the PRO-R is able to provide similar performance as any other online UPS. Built with a true online double-conversion technology, it guarantees consistent and clean electrical power to fully protect your mission-critical devices. In addition, the UPS comes with a built-in master and slave feature to conserve energy when the master device is no longer drawing current. PROLiNK PRO-R works with a variety of applications such as servers, networking and IP telephone systems. • True double conversion online topology • Microprocessor control optimizes reliability • Output power factor 0.8 • Input power factor correction • ECO mode for energy saving • Built-in serial communication port/Dry contact Rear Panel For PRO1000RS 1. 2. 3. 4. 5. Ac Input Output Receptacles: Connect to Mission-critical Loads USB/ RS-232 Serial Communication Port ROO/ PRO Function Connector SNMP Intelligent Slot 1 2 4 3 5 IPS1000RS For PRO1000RL 1. 2. 3. 4. 5. 6. 7. Ac Input Output Receptacles: Connect to Mission-critical Loads USB/ RS-232 Serial Communication Port ROO/ PRO Function Connector SNMP Intelligent Slot Dry Contact External Battery Connector 5 6 7 2 1 4 IPS1000RL 44 Online UPS Full Specifications MODELS PRO1000RS PRO1000RL Capacity 1000 VA 1000 VA 110/120 VAC or 220/230/240 VAC 220/230/240 VAC 55-150 VAC or 110-300 VAC @ 50% load 80-150 VAC or 160-300 VAC @ 100% load 110-300 VAC INPUT Voltage Acceptable Voltage Range Frequency Range 60/50 Hz (Auto sensing) OUTPUT Output Voltage 110/120 VAC or 220/230/240 VAC Voltage Regulation Frequency Range 50/60 ± 0.5% Hz Frequency Range (Batt. Mode) 5:1 (110/120 VAC) 3:1 (220/230/240 VAC) Current Crest Ratio 3:1 ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) Harmonic Distortion Transfer Time 220/230/240 VAC ±1% 40-70 Hz (50/60Hz Auto sensing) AC Mode to Batt. Mode 0ms Inverter to Bypass 4 ms (Typical) Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode 86% Battery Mode 83% BATTERY Battery Type Sealed Lead-acid battery Battery Spec & Numbers Typical Recharge Time INDICATORS 6 V / 7 Ah x 4 Back to 90% capacity in 4 hours LED Lithium-ion battery or Sealed Lead-acid battery Battery Spec & Numbers (Battery voltage: 48VDC) Depending on external battery capacity AC mode, Battery mode, and fault indicators ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) ENVIRONMENT 477 x 438 x 44 300 x 440 x 44 13 6 Humidity 20-90 % RH @ 0- 40°C (Non-condensing) Noise Level Less than 50dBA @ 1 Meter MANAGEMENT USB or RS-232 Dry Contact (Option) Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Signal for AC Power Normal, Battery OK and Fault Alarm L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 45 Online UPS PRO-M Series Online UPS 1kVA - 6kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PRO-M Series is a true online double-conversion UPS system that provides clean and consistent electrical power to those who experience underserved power supply. It is designed with a wide input voltage range to handle voltage fluctuating situations to fail-safe your equipment. The PRO-M Series is noticeably compact in size and is ideal for ATMs, banking and other business critical applications. Users can also adjust the charging current from 1A to 6A to suit their requirements. • • • • • • • • • True double-conversion Microprocessor control optimizes reliability Output power factor 0.8 Wide input voltage (110 V – 300 V) Converter mode available ECO mode for energy saving (Only available for 1-3KVA) Generator compatible Smart SNMP works well with either USB or RS-232 Comprehensive display allows easy monitoring and access of UPS status 3 4 Rear Panel AC input Input circuit breaker USB communication port RS-232 communication port SNMP intelligent slot (optional) External battery connection (only available for EML model) Output receptacles Output circuit breaker Output terminal 5 4 6 For 1kVA to 2kVA model 1. 2. 3. 4. 5. 6. 7. 8. 9. 3 5 7 2 2 1 7 1 PRO801M 5 3 PRO801ML 4 3 5 4 7 2 2 1 7 1 PRO802M PRO802ML 46 Online UPS For 3kVA model 1. 2. 3. 4. 5. 6. 7. 8. 9. 3 AC input Input circuit breaker USB communication port RS-232 communication port SNMP intelligent slot (optional) External battery connection (only available for EML model) Output receptacles Output circuit breaker Output terminal 4 5 3 7 9 2 7 2 9 1 1 PRO803M For 5kVA to 10kVA model 1. 2. 3. 4. 5. External battery connector RS-232 communication port Intelligent slot USB communication Emergency power off function connector (EPO connector) 6. Cooling fan 7. Input circuit breaker 8. Input/ Output terminal (Refer to diagram 3 for the details) 9. Maintenance bypass switch (option) 10. Output terminal 11. Grounding terminal 12. Utility input terminal 5 4 4 2 1 6 PRO803ML 3 5 9 4 2 6 7 1 3 5 6 9 8 6 7 8 11 10 PRO805M / PRO806M / PRO810M 12 PRO805ML / PRO806ML / PRO810ML 47 Online UPS Full Specifications MODELS Phase PRO801M/ ML PRO802M/ ML Capacity 1000 VA 2000 VA INPUT Nominal Voltage Input Voltage Range PRO803M/ ML PRO805M/ ML Single phase with ground 3000 VA PRO806M/ ML PRO810M/ ML 6000 VA 10000 VA 5000 VA 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC 55-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC or 160-280VAC (Based on load at 100%) 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) 40 Hz ~ 70 Hz 46~54 Hz or 56~64 Hz Frequency Range ≧ 0.99 @ Nominal Voltage (100% load) Power Factor OUTPUT Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC Voltage Regulation 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz or 60Hz ± 0.1 Hz Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) 3:1 Current Crest Ratio ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) Harmonic Distortion Transfer Time 208/220/230/240VAC ±1% ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) Zero AC to DC 4 ms (Typical) Inverter to Bypass Zero Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode 88% Battery Mode 90% 83% 85% 2 4 89% 88% 92% 93% 90% 91% BATTERY Battery Type 12 V / 9 Ah Numbers Standard Model 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 115.2 VDC ±1% 273VDC ±1% 218.4 VDC ±1% Depending on the capacity of external batteries 2 3 4 Charging Current Charging Voltage 20 1A/2A Battery Type Long-Run Model 16 Back to 90% capacity in 9 hours 1A Charging Current Numbers 8 Back to 90% capacity in 4 hours Recharge Time (Typical) Charging Voltage 6 6 8 6 8 1A/2A/4A/6A (Adjustable) 27.4 VDC ± 1% 41.0 VDC ± 1% 54.7 82.1 109.4 VDC VDC VDC ±1% ±1% ±1% 82.1 VDC ±1% 109.4 VDC ±1% 115.2 VDC ±1% 16 20 1A/2A/4A/6A (Adjustable) 1A/2A/4 (Adjustable) 218.4 VDC ±1% 273 VDC ±1% INDICATORS LCD Display Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 442 x 190 x 688 369 x 190 x 688 Net Weight (kgs) 9.8 17 Dimension (mm) D × W × H 282 x 145 x 220 Net Weight (kgs) 4.1 27.6 397 x 145 x 220 6.8 7.4 43 61 442 x 190 x 318 369 x 190 x 318 15 12 442 x 190 x 688 66 75 442 x 190 x 318 16 18 ENVIRONMENT Humidity Noise Level 20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH@0-40°C 0-95% RH@0-50°C (Non-condensing) (Non-condensing) 0-95% RH @ 0-40°C (Non-condensing) Less than 50dBA @ 1 Meter Less than 58dBA Less than 55dBA @ 1 Meter @ 1 Meter Less than 58dBA @ 1 Meter MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 48 Online UPS PRO-EM Series Online UPS 1kVA - 10kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PRO-EM Series is a true online double-conversion UPS system that provides clean and consistent electrical power to those who experience underserved power supply. It is designed with a wide input voltage range to handle voltage fluctuating situations to fail-safe your equipment. Also, the UPS provides better output factor of up to 0.9 and is ideal for ATMs, banking and other business critical applications. PRO-EM Series comes with standard USB and RS-232 communication ports and a built-in intelligent slot for additional options such as adapters, protocol converters and relay contact cards. • True double-conversion • Microprocessor control optimizes reliability • Input power factor correction • Output power factor 0.9 • Wide input voltage • Converter mode available • ECO mode for energy saving only available for 1-3KVA models • Generator compatible • Smart SNMP works well with either USB or RS-232 • Comprehensive display allows easy monitoring and access of UPS status Rear Panel For 1kVA model 1. 2. 3. 4. 5. 6. 7. AC input Input circuit breaker USB communication port RS-232 communication port SNMP intelligent slot (optional) External battery connection (only available for EML model) Output receptacles 5 3 4 3 5 4 6 7 2 2 1 1 PRO801EM 7 PRO801EML 49 Online UPS For 2kVA to 3kVA model 1. 2. 3. 4. 5. 6. 7. 8. 9. 5 AC input Input circuit breaker USB communication port RS-232 communication port SNMP intelligent slot (optional) External battery connection (only available for EML model) Output receptacles Output circuit breaker Output terminal 4 3 3 5 4 6 7 2 2 7 1 1 PRO802EM 4 3 PRO802EML 3 5 4 5 6 7 9 2 9 2 7 1 1 PRO803EM PRO803EML For 6kVA to 10kVA model 1. 2. 3. 4. 5. External battery connector RS-232 communication port Intelligent slot USB communication Emergency power off function connector (EPO connector) 6. Cooling fan 7. Input circuit breaker 8. Input/ Output terminal 9. Maintenance bypass switch (optional) 10. Output terminal 11. Grounding terminal 12. Utility input terminal 4 2 1 3 5 9 6 6 7 8 4 2 3 1 5 9 6 6 7 8 11 10 PRO810EM 12 PRO810EML 50 Online UPS Full Specifications MODELS Phase PRO801EM/ EML PRO802EM/ EML Capacity 1000 VA 2000 VA INPUT Nominal Voltage PRO803EM/ EML PRO806EM/ EML Single phase with ground 3000 VA PRO810EM/ EML 10000 VA 6000 VA 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC 60-150 VAC or 120-300 VAC at 50% load 90-140 VAC or 180-280 VAC at 100% load 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) 40 Hz ~ 70 Hz 46~54 Hz or 56~64 Hz Input Voltage Range Frequency Range ≧ 0.99 @ Nominal Voltage (100% load) Power Factor OUTPUT Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC Voltage Regulation Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz 50 Hz or 60Hz ± 0.5% 50 Hz or 60Hz ± 0.1 Hz 3:1 Current Crest Ratio ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) Harmonic Distortion Transfer Time 208/220/230/240VAC ±1% ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) Zero AC to DC 4 ms (Typical) Inverter to Bypass Zero Pure Sinewave Waveform (Batt. Mode) EFFICIENCY AC Mode 88% 89% 90% Battery Mode 83% 85% 88% 2 4 94% 90% 91% 16 20 BATTERY Battery Type Numbers Standard Model 12 V / 9 Ah Recharge Time (Typical) Back to 90% capacity in 9 hours 1.0A 1A, 2A (Adjustable) Charging Current Charging Voltage 27.4VDC ± 1% Battery Type Long-Run Model Numbers Charging Current Battery Type 6 Back to 90% capacity in 4 hours 2 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% Depending on the capacity of external batteries 4 1A/2A/4A/6A 54.7 VDC ±1% 6 82.1 VDC ±1% 273 VDC ±1% 16 20 1A, 2A, 4A (Adjustable) 218.4 VDC ±1% 273 VDC ±1% INDICATORS LCD Display Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369 x 190 x 688 9.8 17 27.6 61 76 282 x 145 x 220 397 x 145 x 220 397 x 145 x 220 369 x 190 x 318 442 x 190 x 318 4.1 6.8 7.4 12 16 20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH@0-50°C (Non-condensing) 0-95% RH @ 0-40°C (Non-condensing) Less than 50dBA @ 1 Meter Less than 55dBA @ 1 Meter Less than 58dBA @ 1 Meter 442 x 190 x 688 ENVIRONMENT Humidity Noise Level MANAGEMENT Smart RS-232 / USB Optional SNMP Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 51 Online UPS Giant Series Online UPS 30kVA - 80kVA Local Area Telecommunication Network Devices (LAN) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) PROLiNK Giant Series (3P/3P) three-phase input/ three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications. The front access design makes it easy for users to perform maintenance and replacement activities. A parallel redundant system is implemented in the Giant Series to provide adequate power supply in the event where a single module fails or needed to be taken offline for service. The Giant Series (3P/3P) also comes with a built-in transformer to provide 100% protection against unexpected AC power problems. • True double-conversion • Microprocessor control optimizes reliability • Input power factor correction • Output power factor 0.9 • Wide input voltage • Converter mode available • Generator compatible • Smart SNMP works well with either USB or RS-232 • Comprehensive display allows easy monitoring and access of UPS status 1 Rear Panel For 30kVA to 80kVA model Intelligent slot Output circuit breaker Input circuit breaker Emergency power off function connector (EPO connector) 5. USB communication 6. RS-232 communication port 7. RS-485 communication port 8. Parallel connection 9. AC input 10. Bypass 11. Maintenance bypass 12. AC output 13. Battery 2 3 5 4 6 7 1 2 3 5 4 6 7 1. 2. 3. 4. 8 8 9 9 10 10 11 12 13 11 12 13 PRO633030S / PRO633040S PRO633060S / PRO633080S 52 Online UPS Full Specifications MODELS PRO633030S PRO633040S PRO633060S PRO633080S Capacity 30 kVA 40 kVA 60 kVA 80 kVA INPUT Nominal Voltage Acceptable Voltage Range 3 x 380VAC/400VAC (3Ph + N) 304VAC ~ 440VAC 50/60 Hz ± 10 % Frequency INVERTER Nominal Voltage 3 x 380VAC/400VAC (3Ph + N) Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz Max. Synchronisation Speed ±1 Hz/s Waveform Pure Sinewave Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load) 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Phase Displacement 1 cycle at 98 % of the static value Dynamic Recovery Time Admissible Overload 110% for 60min,125% for 10 min, 150% for 60s Admissible Crest Factor 3:1 Admissible Power Factor 0.6~1 (inductive or capacitive) Imbalance Output Voltage @ 100% Unbalanced Load <1% High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit Current Limit STATIC BYPASS Type Solid state Voltage 3 x 380VAC/400VAC (3Ph + N) Frequency 50/60 Hz Activation Criterion Microprocessor control Transfer Time Zero Admissible Overload Transfer to Bypass 200% for 10 sec Immediate, for overloads above 150% Automatic after alarm clear Retransfer MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) 50/60 Hz Frequency Overall Efficiency Overall Efficiency 90% Low Battery 95% BATTERY & CHARGER Battery Type and Numbers 12V x 30 pcs, sealed lead acid battery 360 VDC Nominal Battery Voltage Charging Method CC/CV Precision ±1% Charging Current 40 A Charging Voltage 405 VDC PHYSICAL Dimensions, D x W x H(mm) Net Weight (Kgs) 847.5 x 432.4 x 1134.5 271.5 L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice. 1054 x 508 x 1287 298 462 532 53 Online UPS Jupiter Series (3P/3P) Online Jupiter Series 10kVA - 320kVA Key Features • True Galvanic Isolation technology designed to provide full protection against high voltage surges, noise and leakage current etc • Plug and Play modular design allows users to carry out maintenance and repair works effortlessly • Cold start function • Multi-CPU design • Hot-swappable battery design • Temperature compensation for battery charging • Wide input voltage range • Output power factor of 0.80 • Software and Hardware redundant design • EMI suppression provides approximately 200dB noise reduction • Static Bypass Switch provides automatic transfer to a back-up power source in the event of a failure within the UPS • Maintenance Bypass Switch • Smart battery charger designed to optimize battery performance • LCD User Interface Options • Remote control panel • PC monitoring software • Auto dialling module • SNMP/ HTTP network card • Emergency Power Off switch (EPO) 54 Online UPS Full Specifications 10KVA ~ 60KVA UPS 3-Phase Input / 3-Phase Output MODELS PRO533010S PRO533020S PRO533030S PRO533040S PRO533050S PRO533060S Capacity 10kVA 20kVA 30kVA 40kVA 50kVA 60kVA INPUT Input Voltage 380 / 400 / 415VAC 3 Phase 4 Wire Input Range 307 – 520V Input Frequency 50 / 60Hz +/- 7% Input Power Factor 0.8 Normal Input Current(A) 18 36 54 72 90 108 Maximum Input Current(A) 24 45 68 90 113 136 135 162 25 30 Power Walk In 0% - 100% : 20 sec Efficiency 99% 1% Voltage Regulation 27 Current Limit(A) 54 81 Ripple Voltage 108 0.5% BATTERY Type Seal Lead Acid / NiCd No. Of Cells 174 / 271 Voltage Range Maximum Charge Current (Adc) 5 10 295 – 410VDC / 285-415VDC 15 20 Battery Low Voltage 320VDC / 305VDC Battery Low Stop 295VDC / 285VDC Boost Charge 402VDC / 415VDC Float Charge 390VDC / 410VDC INVERTER 285 – 420VDC Dc Input Range Wave Form Sinusoid Output Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire Output Power Factor 0.8 +/-1% Voltage Regulation 100% Unbalance Load Frequency Lock Range 45 – 55Hz / 55 – 65Hz 50 / 60Hz + / - 0.1Hz Output Frequency (Free Running) Phase Shift Under 100% Unbalance Load 120 % + / - 0.5° <2% THD (Linear Load) Overload <110% 110 - 125% Continuous 15 min 125 - 150% >150% 10 min 60 sec Efficiency (100% Load) 93% Maximum Output Peak Current(A) 43 87 93.5% 130 174 94% 218 260 STATIC SWITCH Voltage Range 173 – 277 VAC (Line To Neutral) Frequency Range 45 – 55Hz / 55 – 65Hz Efficiency Transfer Time Overload 99.5% Mains > Inverter 0 ms 0 ms Inverter > Mains 100% 30 sec 300% 1 sec Yes Isolation With Output OVERALL CHARACTERISTICS 91% Overall Efficiency 91.5% 92% OPERATING ENVIRONMENT Temperature 0 – 40°F ( 32 – 104°F ) 0% - 90% ( Non–condensing ) Humidity <1500m Above Sea Level Altitude Maximum Heat Dissipation(Kw) 0.65 1.3 1.9 2.6 3 3.5 Weight(Kg) (No Battery) 270 300 400 480 550 680 Dimension (mm) D x W x H 800 x 550 x 1600 Audible Noise < 65 dBA (@ 1 m) Standards Protections En50091-1,-2 Yes Short Circuit Rectifier, Reserve, Bypass Nfb Lightning Mov Emc Filter Input & Output Galvanic Isolation Between Input & Output Yes Data Display By Lcd Indications & Alarms Yes Fcc Class A LED,LCD,BUZZER Yes Dry Contact Yes Battery Start Yes 55 Online UPS 80KVA ~ 160KVA UPS 3-Phase Input / 3-Phase Output MODELS PRO533080S PRO533100S PRO533120S PRO533160S Capacity 80kVA 100kVA 120kVA 160kVA INPUT Input Voltage 380 / 400 / 415VAC 3 Phase 4 Wire Input Range 307 – 520V Input Frequency 50 / 60Hz +/- 7% Input Power Factor 0.8 Normal Input Current(A) 144 180 216 288 Maximum Input Current(A) 180 225 270 360 324 432 295 – 410VDC / 285-415VDC 50 60 80 Power Walk In 0% - 100% : 20 sec Efficiency 99% Voltage Regulation 1% 216 Current Limit(A) 270 Ripple Voltage 0.5% BATTERY Type Seal Lead Acid / NiCd No. Of Cells 174 / 271 Voltage Range Maximum Charge Current (Adc) 40 Battery Low Voltage 320VDC / 305VDC Battery Low Stop 295VDC / 285VDC Boost Charge 402VDC / 415VDC Float Charge 390VDC / 410VDC INVERTER 285 – 420VDC Dc Input Range Wave Form Sinusoid Output Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire Output Power Factor 0.8 +/-1% Voltage Regulation 100% Unbalance Load Frequency Lock Range 45 – 55Hz / 55 – 65Hz 50 / 60Hz + / - 0.1Hz Output Frequency (Free Running) Phase Shift Under 100% Unbalance Load 120 % + / - 0.5° <2% THD (Linear Load) Overload <110% 110 - 125% Continuous 15 min 125 - 150% >150% 10 min 60 sec Efficiency (100% Load) 94.5% Maximum Output Peak Current(A) 348 95% 432 520 693 STATIC SWITCH Voltage Range 173 – 277 VAC (Line To Neutral) Frequency Range 45 – 55Hz / 55 – 65Hz Efficiency Transfer Time Overload 99.5% Mains > Inverter 0 ms 0 ms Inverter > Mains 100% 30 sec 300% 1 sec Yes Isolation With Output OVERALL CHARACTERISTICS 92.5% Overall Efficiency 93% OPERATING ENVIRONMENT Temperature 0 – 40°F ( 32 – 104°F ) 0% - 90% ( Non–condensing ) Humidity <1500m Above Sea Level Altitude Maximum Heat Dissipation(Kw) 4.6 5.4 6.5 8.7 Weight(Kg) (No Battery) 820 950 1180 1450 Dimension (mm) D x W x H 800 x 1100 x 1600 Audible Noise < 65 dBA (@ 1 m) Standards Protections En50091-1,-2 Yes Short Circuit Rectifier, Reserve, Bypass Nfb Lightning Mov Emc Filter Input & Output Galvanic Isolation Between Input & Output Yes Data Display By Lcd Indications & Alarms Yes Fcc Class A LED,LCD,BUZZER Yes Dry Contact Yes Battery Start Yes 56 Online UPS 200KVA ~ 320KVA UPS 3-Phase Input / 3-Phase Output MODELS PRO533200S PRO533240S PRO533300S PRO533320S Capacity 200kVA 240kVA 300kVA 320kVA INPUT Input Voltage 380 / 400 / 415VAC 3 Phase 4 Wire Input Range 307 – 520V Input Frequency 50 / 60Hz +/- 7% Input Power Factor 0.8 Normal Input Current(A) 350 420 525 560 Maximum Input Current(A) 437 525 656 700 788 840 295 – 410VDC / 285-415VDC 120 150 160 Power Walk In 0% - 100% : 20 sec Efficiency 99% Voltage Regulation 1% 525 Current Limit(A) 630 Ripple Voltage 0.5% BATTERY Type Seal Lead Acid / NiCd No. Of Cells 174 / 271 Voltage Range Maximum Charge Current (Adc) 100 Battery Low Voltage 320VDC / 305VDC Battery Low Stop 295VDC / 285VDC Boost Charge 402VDC / 415VDC Float Charge 390VDC / 410VDC INVERTER 285 – 420VDC Dc Input Range Wave Form Sinusoid Output Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire Output Power Factor 0.8 +/-1% Voltage Regulation 100% Unbalance Load Frequency Lock Range 45 – 55Hz / 55 – 65Hz 50 / 60Hz + / - 0.1Hz Output Frequency (Free Running) Phase Shift Under 100% Unbalance Load 120 % + / - 0.5° <5% THD (Linear Load) Overload <110% 110 - 125% Continuous 15 min 125 - 150% >150% 10 min 60 sec Efficiency (100% Load) 95% Maximum Output Peak Current(A) 800 1000 1250 1300 STATIC SWITCH Voltage Range 173 – 277 VAC (Line To Neutral) Frequency Range 45 – 55Hz / 55 – 65Hz Efficiency 99.5% Mains > Inverter Transfer Time 0 ms 0 ms Inverter > Mains Overload 100% 30 sec 300% 1 sec Yes Isolation With Output OVERALL CHARACTERISTICS 93% Overall Efficiency OPERATING ENVIRONMENT Temperature 0 – 40°F ( 32 – 104°F ) 0% - 90% ( Non–condensing ) Humidity <1500m Above Sea Level Altitude Maximum Heat Dissipation(Kw) 11.5 13 16.3 17.4 Weight(Kg) (No Battery) 2500 2700 3000 3100 Dimension (mm) D x W x H 800 x 2200 x 1600 Audible Noise < 65 dBA (@ 1 m) Standards Protections En50091-1,-2 Yes Short Circuit Rectifier, Reserve, Bypass Nfb Lightning Mov Emc Filter Input & Output Galvanic Isolation Between Input & Output Yes Data Display By Lcd Indications & Alarms Yes Fcc Class A LED,LCD,BUZZER Yes Dry Contact Yes Battery Start Yes *All specifications, designs and contents are subject to change without prior notice. 57 Line Interactive UPS PRO SFC Series Super Fast Charging Line Interactive Series 650VA - 1200VA PC Printer Work-Stations PROLiNK SFC series is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNK’s latest Super-Fast Charging technology. This cutting-edge technology is able to recharge the battery back to 90% of its capacity within 2-4 hours, and is ideal for providing stable backup power to home/ small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universal sockets to provide better compatibility with a wider range of devices. • Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours • Excellent microprocessor control guarantees high reliability • Boost and buck AVR for voltage stabilization • Auto restart while AC is recovering • Simulated sine wave • Off-mode charging • Cold start function • Optional USB/RS-232 communication port and RJ-11/RJ-45 protection Rear Panel For 650VA to 1200VA model 1. 2. 3. 4. 5. AC Input Backup Output Bypass Output (without battery back up) USB Port (Only available in SFCU series) RJ11 4 4 4 5 5 1 2 1 2 2 1 2 2 PRO700SFC/ SFCU PRO850SFCU 2 3 PRO1200SFC/ SFCU 58 Line Interactive UPS Full Specifications MODELS Capacity VA PRO700SFC/ SFCU PRO850SFCU PRO1200SFC/ SFCU 650 850 1200 INPUT Nominal Voltage 220/ 230/ 240VAC Voltage Range 140-300VAC Nominal Frequency 50 or 60Hz (Auto Sensing) OUTPUT Output Voltage Regulation (Battery Mode) ±10% Frequency 50Hz or 60Hz ±1Hz Transfer Time (Typical) Typical 2-6 ms 2 - 6ms, 10ms (max) Waveform Simulated Sinewave BATTERY Number of Battery 1 x 12V8.2AH Recharge Time (Typical) 1 x 12V10AH 2 x 12V8.2AH Back to 90% capacity in 2-4 hours PROTECTION Full Protection Short Circuit, Overload, Discharge and Overcharge Protection INDICATION AC Mode – Green Lighting Battery Mode – Yellow Lighting LED Display Charging Mode – Green Flashing every 2 seconds Overload – Red Flashing every 0.5 seconds Fault – Red Lighting ALARM Battery Mode – Sounding every 10 seconds Low Battery – Sounding every second Overload – Sounding every 0.5 seconds Sounding Battery Replacement Alarm – Sounding every 2 seconds Fault – Continuously Sounding PHYSICAL 287 x 100 x 142 Dimension (mm) D x W × H Net Weight (kgs) 4.25 350 x 146 x 160 4.9 8 ENVIRONMENT Humidity 0-90% relative Humidity, 0°C - +40°C Noise Level Less than 40dB MANAGEMENT USB/ RS-232 *All specifications, designs and contents are subject to change without prior notice. Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC 59 Line Interactive UPS PRO SFT Series Super Fast Charging Line Interactive With Touch Screen Panel 650VA - 1200VA PC Printer Work-Stations The PRO SFT series is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNK's latest Super-Fast Charging technology. It allows for the battery to be recharged back to 90% of its capacity within 2-4 hours, and is ideal for providing stable backup power to home/ small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This helps prevent under voltage brownouts and over voltage surges. The unit also comes with a LCD user interface that provides valuable information such as output voltage, input voltage, load level, battery voltage and overload warning signals. • Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours • Excellent microprocessor control guarantees high reliability • Boost and buck AVR for voltage stabilization • Auto restart while AC is recovering • Simulated sine wave • Off-mode charging • Cold start function • LCD User Interface Rear Panel 4 For 650VA to 1200VA model 1. 2. 3. 4. 5. AC Input Backup Output Bypass Output (without battery back up) USB Port (Only available in SFTU series) RJ11 4 4 5 5 1 2 1 2 2 1 2 2 PRO700SFT/ SFTU PRO850SFTU 2 3 PRO1200SFT/ SFTU 60 Line Interactive UPS Full Specifications MODELS Capacity VA PRO700SFT/ SFTU PRO850SFTU PRO1200SFT/ SFTU 650 850 1200 INPUT Nominal Voltage 230VAC Voltage Range 140-300VAC Nominal Frequency 50 or 60Hz (Auto Sensing) OUTPUT Output Voltage Regulation (Battery Mode) +/ -10% Frequency 50Hz or 60Hz +/ -1 Hz Transfer Time (Typical) Typical 2-6 ms 2 - 6ms, 10ms (max) Simulated Sinewave Waveform BATTERY Number of Battery 1 x 12V8.2AH Recharge Time (Typical) 1 x 12V10AH 2 x 12V8.2AH Back to 90% capacity in 2-4 hours PROTECTION Full Protection Short Circuit, Overload, Discharge and Overcharge Protection Display LCD Display Input voltage, output voltage, battery level, load level and UPS status ALARM Battery Mode – Sounding every 10 seconds Low Battery – Sounding every second Overload – Sounding every 0.5 seconds Sounding Battery Replacement Alarm – Sounding every 2 seconds Fault – Continuously Sounding PHYSICAL 300 x 101 x 142 Dimension (mm) D x W × H Net Weight (kgs) 4.4 350 x 146 x 160 5 8 ENVIRONMENT Humidity 0-90% relative Humidity, 0°C - 40°C (Non -condensing) Noise Level Less than 40dB MANAGEMENT USB/ RS-232 *All specifications, designs and contents are subject to change without prior notice. Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC 61 Line Interactive UPS PRO Series Line Interactive Series 650VA – 1200VA PC Printer Work-Stations PRO Series is a single-phase input / single-phase output line-interactive UPS system. It is able to provide clean electrical power and is ideal for home / small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universal sockets to provide better compatibility with a wider range of devices. • Built-in super smart charger, shorten 50% of charging time • Excellent microprocessor control guarantees high reliability • Boost and buck AVR for voltage stabilization • Auto restart while AC is recovering • Simulated sine wave • Off-mode charging • Cold start function • Optional USB/RS-232 communication port and RJ-11/RJ-45 protection • Offering LED and LCD panels for selections Rear Panel For 650VA to 1200VA model 1. 2. 3. 4. 5. AC Input Backup Output Bypass Output (without battery back up) USB Port (Only available in VU and SVU series) RJ11 4 4 4 5 1 1 2 1 2 5 3 2 1 2 2 2 PRO700V/ VU PRO850VU 2 PRO850SU 2 3 PRO1200SV/ SVU 62 Line Interactive UPS Full Specifications MODELS Capacity VA PRO700V/ VU PRO850VU/ SU PRO1200SV/ SVU 650 850 1200 INPUT Nominal Voltage 220/ 230/ 240VAC Voltage Range 140-300VAC Nominal Frequency 50 or 60Hz (Auto Sensing) OUTPUT Output Voltage Regulation (Battery Mode) ±10% Frequency 50Hz or 60Hz ±1Hz Transfer Time (Typical) Typical 2-6 ms 2 - 6ms, 10ms (max) Simulated Sinewave Waveform BATTERY Number of Battery 1 x 12V8.2AH Recharge Time (Typical) 1 x 12V10AH 2 x 12V8.2AH Back to 90% capacity in 4-6 hours PROTECTION Full Protection Overload, discharge, and overcharge protection INDICATION AC Mode – Green Lighting Battery Mode – Yellow Lighting LED Display Charging Mode – Green Flashing every 2 seconds Overload – Red Flashing every 0.5 seconds Fault – Red Lighting ALARM Battery Mode – Sounding every 10 seconds Low Battery – Sounding every second Overload – Sounding every 0.5 seconds Sounding Battery Replacement Alarm – Sounding every 2 seconds Fault – Continuously Sounding PHYSICAL 287 x 100 x 142 Dimension (mm) D x W × H Net Weight (kgs) 4.25 350 x 146 x 160 4.9 8 ENVIRONMENT Humidity 0-90% relative Humidity, 0°C - +40°C Noise Level Less than 40dB MANAGEMENT USB/ RS-232 *All specifications, designs and contents are subject to change without prior notice. Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC 63 Line Interactive UPS PRO-L Series Line Interactive Series 600VA – 2000VA PC Printer Work-Stations PRO-L Series is a single-phase input / single-phase output line-interactive UPS system that provides clean and reliable back-up power for longer periods of time. It is able to provide clean electrical power and is ideal for home / small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PRO-L Series with capacities of up to 850VA also comes with universal sockets to provide better compatibility with a wider range of devices. • Excellent microprocessor control guarantees high reliability • Boost and buck AVR for voltage stabilization • Adjustable battery charging current • Auto restart while AC is recovering • Off-mode charging • Cold start function • Simulated sine wave Rear Panel For 600VA to 2000VA model 1. 2. 3. 4. 5. AC input Input protection Output outlet Battery Connection Fan 1 4 4 5 2 1 5 2 3 3 3 PRO700L PRO1000L/ PRO2000L 64 Line Interactive UPS Battery Pack For 600VA to 2000VA model Model G6 Battery Type G12 G18 G60 12V7AH/ 12V9AH/ 12V10AH Battery Number Dimension (DxWxH) mm 6 pcs 12 pcs 18 pcs 60 pcs 397 × 145 × 220 421 × 190 × 318 535 × 190 × 318 830 x 250 x 576 Full Specifications MODELS Capacity VA PRO700L PRO1000L PRO2000L 600 1000 2000 INPUT Nominal Voltage 220/ 230/ 240VAC Voltage Range 140 - 300VAC Nominal Frequency 50Hz OUTPUT Output Voltage Regulation (Battery Mode) ±10% Frequency 50 Hz ±1 Hz Typical 4-8 ms Transfer Time (Typical) Simulated Sinewave Waveform BATTERY Battery Voltage Battery Capacity Charging Current (max.) 12VDC 24VDC Depending on the application 2.5A/ 6A/ 10A (adjustable) 5A/ 10A/ 15A/ 20A (adjustable) PROTECTION Full Protection Overload, discharge, and overcharge protection INDICATION AC Mode – Green Lighting LED Display Battery Mode – Yellow Lighting Fault – Red Lighting ALARM Low Battery – Sounding every second Overload – Sounding every 0.5 seconds Sounding Battery Replacement Alarm – Sounding every 2 seconds Fault – Continuously Sounding PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 358.5 x 96.8 x 146.5 5.8 395 x 145 x 220 9.0 13.55 ENVIRONMENT Humidity 0-90% relative Humidity, 0°C - +40°C Noise Level *All specifications, designs and contents are subject to change without prior notice. Less than 40dB 65 Line Interactive UPS PRO Rack/ Tower Series Line Interactive Series 800VA – 3000VA PC Printer Work-Stations 19” Rack Mount PRO Rack / Tower series is a single-phase input / single-phase output UPS that employs a line-interactive technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket. With its high density output power factor of 0.8, this device is able to provide outstanding performance and efficiency for any home / small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. • Microprocessor-based line interactive design • Pure sine wave output online mode and battery mode • User-friendly and easy-shift LCD display • Rack/Tower design • Built-in boost and buck AVR • Output Power Factor 0.8 • Hot swappable battery design • Programmable power management outlets • Emergency Power Off Function (EPO) • Long-run models available • Multiple communication available • Option for SNMP communication. Rear Panel 9 For 800VA to 3000VA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. Battery Compartment (only available for Standard model) 11. Output terminal (IEC320-14) 12. Fan 13. External battery pack numbers detection port 8 6 7 13 1 5 12 4 3 4 3 2 PRT800S 9 8 6 7 13 12 1 5 10 2 PRT1100S/ PRT1100L/ PRT2000S/ PRT2000L 5 12 12 10 7 8 9 6 13 3 1 11 2 4 PRT3000S/ PRT3000L 66 Line Interactive UPS Battery Pack For 1.1kVA to 3kVA model Model G8R Battery Type G12R G20R 12V7AH/ 12V9AH/ 12V10AH Battery Number Dimension (DxWxH) mm 8 pcs 12 pcs 20 pcs 480 x 438 x 88 600 x 438 x 88 580 x 438 x 133 Full Specifications MODELS PRT800S PRT1100S/ L PRT2000S/ L PRT3000S/ L Capacity 800 VA 1100 VA 2000 VA 3000 VA INPUT Nominal Voltage 208/ 220/ 230/ 240VAC Voltage Range 162 ~ 290VAC Nominal Frequency 50 or 60Hz OUTPUT Voltage Regulation (Batt. Mode) ±3% Frequency 50Hz or 60Hz ±1Hz Power Factor 0.8 3:1 Current Crest Ratio Voltage Distortion ≦ 8% THD Liner Load ≦ 15% THD Non-Liner Load Pure Sinewave Waveform EFFICIENCY AC Mode Up to 97% BATTERY Type Standard Model Capacity Value regulated Lead Acid battery (Maintenance free batteries) 7AH 9AH Recharge Time (Typical) Back to 90% capacity in 4 hours Charging Current Type Long-Run Model 1.0 A (max.) Depending on the application Capacity Charging Current INDICATORS LCD Display Depending on the application N/A 4A / 8A AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery PHYSICAL Standard Model Long-Run Model Dimension (mm) D × W × H Net Weight (kgs) Dimension (mm) D x W × H Net Weight (kgs) 480 x 438 x 88 380 x 438 x 88 12.9 N/A 600 x 438 x 88 14.23 23.1 32.24 380 x 438 x 88 480 x 438 x 88 600 x 438 x 88 10.8 14 18 ENVIRONMENT Operation Humidity Ambient Temperature Noise Level 0-90% (Non-condensing) 0°C - +40°C ≤ 45dB @ 1 Meter MANAGEMENT USB/ RS-232 *All specifications, designs and contents are subject to change without prior notice. Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC 67 Line Interactive UPS Outdoor Line Interactive UPS Outdoor Line Interactive Series PC Work-Stations CCTV Traffic Light Control System The PROLiNK® PRO2000LD is a single-phase input/ single-phase output Outdoor UPS system. A wide operating temperature range of -40°C to 80°C makes it ideal for outdoor usage. Designed to put up the best performance under the harshest environment, the PRO2000LD is able to supply continuous power to critical loads during a blackout or power outage. Equipped with dry contacts, the PRO2000LD is able to program safety-oriented signals to meet the requirements of different applications. As such, users are able to monitor UPS events that are most concerned to them. The PRO2000LD comes in a capacity of 2000VA. • Selectable transfer time for normal or generator mode • User-adjustable charging current • Adjustable input threshold voltage • Provides programmable signals for dry contacts • Battery compensation design • RS-232, USB and SNMP intelligent port interface Front Panel For 2000VA model 1. AC input terminal block 2. AC input breaker 3. AC output terminal block 4. AC output breaker 5. Input contact 6. Dry contact 7. Internal fan 8. GND 9. Battery connector 10. Battery temperature sensor 11. External FAN connector 12. PTS control connector 13. Battery breaker 14. Battery voltage test points 15. Function keys 16. Liquid Crystal Display (LCD) 17. Indicator LEDs 18. USB connector 19. RS232 connector 20. Intelligent slot (optional) 14 19 18 20 1 2 4 3 16 17 5 15 6 7 13 12 11 10 8 9 PRO2000LD 68 Line Interactive UPS Full Specifications MODELS PRO2000LD 2000 VA Rated Power INPUT Nominal Voltage 230VAC Acceptable Voltage Range Frequency Range 170-300VAC 50 Hz/60 Hz (Auto sensing) OUTPUT Nominal Voltage 230VAC Voltage Regulation (Batt. Mode) 230VAC ± 5% Output Frequency 50Hz/60Hz ± 0.1% THD (Batt. Mode) <3% @ Full resistive load Efficiency Liner Mode 95% AVR Mode 90% Battery Mode Transfer Time Normal Mode (max.) Generator Mode (max.) Waveform BATTERY 90% 12ms 25ms Pure Sinewave Nominal DC Voltage Low DC Warning Voltage Battery Type Charging Current INDICATORS 48VDC 46VDC ± 0.4VDC @ no load AGM/Gel 2A/4A/6A/8A/10A (Adjustable) Depending on the application Bypass Mode Green LED On Battery Mode Green LED Flashing Green LED Off No Output Warning with Output Yellow LED On Fault without Output Red LED On MANAGEMENT Communication Dry Contact Rating RS-232/USB and SNMP 3A @ 250Vac PHYSICAL Dimension (mm) D × W × H 400 x 240 x 133 Net Weight (kgs) 12.5 Type of Mechanical Protection IP 20 ENVIRONMENT Operation Humidity Operating Temperature Noise Level 5% to 95% Relative Humidity (Non-condensing) -40°C to 80°C < 48dB COMPLIANCE EMI Compliance Class A FCC/CISPR [EN50091-2: 1995] Surge Protection IEEE/ANSI C.62.41 & 2KV, L-N *All specifications, designs and contents are subject to change without prior notice. 69 Inverter UPS IPS Series Inverter Series PROLiNK IPS Series is a compact home inverter system that delivers high efficiency conversion from DC to AC power. This economically ideal system provides clean and stable power for home appliances and generator related devices. In cases where the electrical utility is down, the home inverter system is able to draw DC current from the battery and supply power to all the AC loads connected to it. Covering a wide selection of sizes, the IPS Series is available in capacities as low as 600VA to as high as 5000VA. • Selectable Voltage Range (Except for IPS600) • Advanced Protection • Auto restart while AC is recovering • Comes with a built-in transformer (Only applies to IPS600, IPS850 & IPS1500) • LCD and/or LED panel (Refer to the specifications) 4 Rear Panel 1 For IPS600 1. 2. 3. 4. 4 AC input Output receptacles Circuit breaker External battery connector 3 2 IPS600 For IPS700 and IPS1201 1. 2. 3. 4. 5. 6. Input voltage range selector AC input Input breaker External battery connector Charge current selector Output receptacles 1 5 3 2 6 4 IPS700/ IPS1201 4 70 Inverter UPS For IPS850 and IPS1500 1. 2. 3. 4. 5. 6. Input voltage range selector AC input Input breaker External battery connector Charge current selector Output receptacles 1 5 3 6 2 4 4 IPS850/ IPS1500 For IPS1200 and IPS2400 1. 2. 3. 4. 5. 6. 6 Operation mode selector AC input Input breaker External battery connectors Charge current selector Output receptacles 1 2 5 3 4 IPS1200/ IP2400 For IPS3000 and IPS5000 1. 2. 3. 4. Battery connector Input protector AC input Inverter output 2 3 4 2 3 1 4 IPS3000 1 IPS3001 2 3 4 1 IPS5000 71 Inverter UPS Full Specifications Simulated Sinewave Inverter MODELS Capacity VA INPUT Nominal Voltage Voltage Range IPS600 IPS850 IPS1200 IPS1500 IPS2400 600VA/ 360W 850VA/ 600W 1200VA 1500VA/ 1050W 2400VA 230 VAC 120 VAC or 230 VAC 220/ 230/ 240 VAC 120 VAC or 230 VAC 220/ 230/ 240 VAC 100 – 290 VAC 90-145 VAC/ 90-145 VAC/ 180-260 VAC 170-280 VAC 180-260 VAC 170-280 VAC (For Personal Computers) (For Personal Computers) (For Personal Computers) (For Personal Computers) 50-160 VAC/ 90-280 VAC 50-160 VAC/ 90-280 VAC 100-300 VAC (For Home Appliances) 100-300 VAC (For Home Appliances) (For Home Appliances) (For Home Appliances) Frequency Range 50/60 Hz (Auto Sensing) OUTPUT AC Voltage Regulation (Batt. Mode) Transfer Time 200 ~ 230VAC ± 5% 120VAC ± 10% or 230VAC ± 10% 230VAC ± 10% 120VAC ± 10% or 230VAC ± 10% 230VAC ± 10% 13 ms (Typical) 20 ms (max) 10 ms (Typical) 20 ms (max) 20 ms (max) 10 ms (Typical) 20 ms (max) >95% Not Applicable >95% 13.7 VDC ± 0.25 VDC Not Applicable 27.4 VDC ± 2% 20.4 VDC ± 2% 27.4 VDC ± 0.5 VDC Not Applicable Not Applicable Waveform (Batt. Mode) Simulated Sinewave >95% @ Rated R load and battery full charged Peak Efficiency Not Applicable BATTERY Battery Voltage 12 VDC 24 VDC Floating Charge Voltage Low Battery Alarm Voltage 3.7 VDC ± 2% 10.8 VDC ± 2% 10.2 VDC ± 2% Shutdown Voltage 10.0 VDC ± 2% 9.9 VDC ± 2% Not Applicable 19.8 VDC ± 2% Overcharge Protection 14.5 VDC ± 2% 15 VDC ± 2% 15 VDC 30 VDC ± 2% 30 VDC 13A 10A or 20A 10A or 20A (Selectable) 10A or 20A 10A or 20A (Selectable) Maximum Charge Current PROTECTION Overload, deep discharge, overcharge and short circuit protection Full Protection Overload and short circuit protection INDICATORS AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery LCD Display LED Display Not Applicable Input Voltage, Output Voltage, Load level, Battery level and Fault alarm Not Applicable Input Voltage, Output Voltage, Load level, Battery level and Fault alarm Line Mode Fault Green Lighting Red Lighting Not Applicable Red Lighting Green Lighting Red Lighting Not Applicable Red Lighting Battery Mode Low Battery Yellow Flashing Not Applicable Yellow Flashing Yellow Flashing Yellow Flashing Not Applicable Yellow Flashing Yellow Flashing Shutdown Mode Charging Mode Yellow Flashing Yellow Flashing Not Applicable Overload Green Flashing Red Flashing Not Applicable Green Flashing Red Flashing Sounding every 2 seconds Sounding every second Sounding every 2 seconds ALARM Low Battery Sounding every second Overload Sounding every 0.5 second Continuously sounding Fault Battery Replacement Not Applicable Sounding every 2 seconds Not Applicable Sounding every 2 seconds Not Applicable 358.5 x 96.8 x 146.5 4.6 289 x 290 x 127 6.99 293 x 231.5 xx 82.5 2.35 289 x 290 x 127 10 293 x 231.5 xx 82.5 2.55 PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) ENVIRONMENT Humidity 0 to 90% Relative Humidity (Non-condensing) Operating Temperature Storage Temperature 0°C to 40°C -15°C to 50°C *All specifications, designs and contents are subject to change without prior notice. -15°C to 70°C Not Applicable -15°C to 70°C Not Applicable 72 Inverter UPS Full Specifications Pure Sinewave Inverter MODELS Capacity VA IPS700 IPS1201 IPS3000 IPS3001 IPS5000 700VA/ 500W 1200VA/ 840W 3000VA/ 2400W 3000VA/ 2400W 5000VA/ 4200W INPUT Nominal Voltage Voltage Range 230 VAC 170-280 VAC (For Personal Computers) 90-280 VAC (For Home Appliances) 180-270 VAC (Normal Range) 100-270 VAC (Wide Range) 170-280 VAC (Normal Range) 90-280 VAC (Wide Range) Frequency Range 50/60 Hz (Auto Sensing) OUTPUT AC Voltage Regulation (Batt. Mode) 230VAC ± 5% 230VAC ± 10% 10 ms (For Personal Computers) 20 ms (For Home Appliances) Transfer Time Waveform (Batt. Mode) Pure Sinewave Peak Efficiency 90% 95% 90% BATTERY Battery Voltage 12 VDC 24 VDC 48 VDC Floating Charge Voltage Low Battery Alarm Voltage 13.5 VDC 11.5 VDC 21 VDC 53.6 VDC 42 VDC Shutdown Voltage 10.5 VDC 20 VDC 40 VDC 15 VDC 30 VDC 58 VDC 10A or 15A (Selectable) 10A or 20A (Selectable) 20A or 35A (Selectable) Overcharge Protection Maximum Charge Current 27 VDC 27.4 VDC PROTECTION Full Protection Not Applicable Overload and short circuit protection Protection against misconnection and improper usage Not Applicable INDICATORS LCD Display ALARM Low Battery Line Mode, Line mode with charging battery, battery mode, off-mode charging, fault mode, Low Battery, Overload, Power limitation, Fan lock and Overcharge AC Mode, Inverter Mode, Charger Mode Load Level, Fault Sounding every second Sounding every 2 seconds Sounding every 0.5 second Continuously sounding Overload Fault PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 289 x 290 x 127 4.5 4.8 268 x 330 x 76 4.9 330 x 268 x 76 5 350 x 110 x 407 9 ENVIRONMENT Humidity 0 to 90% Relative Humidity (Non-condensing) Operating Temperature Storage Temperature 5 to 95% (Non-condensing) 0°C to 50°C 0°C to 45°C -15°C to 70°C -15°C to 60°C *All specifications, designs and contents are subject to change without prior notice. 73 Auto Voltage Regulator PROLiNK PVR PVR Series PROLiNK PVR Series is designed to automatically maintain a constant voltage level to protect sensitive electronics from brownouts, under voltages and over voltages. The PROLiNK PVR takes efficiency to a new level with its microprocessor controller tailored to allow extremely fast response for detecting and regulating voltage. Equipped with a time-delay function, the PVR is able to protect connected devices from power-back surges. This high performance AVR comes with the versatility to fit all kinds of equipment with its wide input voltage range selection. The PROLiNK PVR provides you with the optimum solution for your everyday needs. • Microprocessor control • Accepts wide input voltage range • Time delay function eliminates transient that can affect connected equipment • Provides stable output voltage • Provides under-voltage, over-voltage, over-heat and over current protection • High voltage cut off Full Specifications MODELS Capacity VA PVR500 D/M PVR1000 D/M PVR2000 D/M PVR3000 D/M 500 1000 2000 3000 INPUT Norminal Voltage Voltage Range 220VAC 110VAC ~ 270VAC or 140VAC ~ 260VAC (selectable) Nominal Frequency 50 or 60Hz (Auto Sensing) OUTPUT Voltage 220VAC Output Voltage Regulation ± 10% EFFICIENCY Normal Mode 95% AVR Mode 92% PROTECTION 10 seconds Delay Time Full Protection Over-voltage, under-Voltage, over-heat and over current Protection INDICATION LED Display Normal indicator, AVR indicator, delay time setting and Fault indicator Input and Output voltage LCD/Meter Display PHYSICAL Dimension, D X W X H (mm) Net Weight (kgs) 196.8 x 110 x 123.5 2.4 233.6 x 134 x 181 6.55 3.91 297.1 x 150 x 199 8.56 ENVIRONMENT Operating Temperature 0°C - +40°C 0-90% relative Humidity (Non-condensing) Humidity D = LCD display, M = Analogue display *All specifications, designs and contents are subject to change without prior notice. 74 DC UPS PROLiNK DC UPS PDC Series - DC UPS PROLiNK PDC series is a compact DC UPS system that converts AC to DC power. This device comes with a built-in dynamic voltage regulator that ensures the voltage from the power source is kept within acceptable limits. The PDC Series is ideal for devices such as switches, hubs, routers and modems. With the built-in DC start function, the PDC UPS can be started up with the absence of AC power. The PROLiNK PDC series is definitely your number one choice for back-up power solution. • Dual DC Outputs • Microprocessor control guarantees high reliability • Compact size for standing and mounting flexibility • Supports solar powered devices and communication applications • Auto restart while AC is recovering • Off-mode charging • Overload protection and short circuit protection Full Specifications MODELS INPUT Nominal Voltage Voltage Range Frenquency PDC50 220VAC 160 - 280VAC 50 or 60Hz OUTPUT Nominal Voltage Output Voltage Regulation Transfer Time 12VDC 10V ~ 13.7V 0ms EFFICIENCY AC Mode Battery Mode >75% at Nominal Voltage (Battery Fully Charged) >95% at Full Load BATTERY Battery Type Charging Voltage Charging Current Typical Recharge Time 12V9AH x 1 13.7V ±0.25V 2.8A or 2.3A at Nominal Voltage without Load Back to 90% capacity in 4-6 hours INDICATION AC Mode Green Lighting Battery Mode Yellow Lighting Low Battery Yellow Flashing Fault PROTECTION Full Protection Red Lighting Short Circuit and Overload Protection PHYSICAL Dimension (mm) D x W × H @ Vertically Stand Net Weight (kgs) 228 x 82.5 x 207 3 ENVIRONMENT Humidity Temperature 0 ~ 90% 0°C ~ 40°C 75 DC UPS PROLiNK DC BACK-UP UNIT PBU Series PROLiNK Back-Up (PBU) unit is a user-friendly lighting power supply unit that is suitable for home/ outdoor settings. This portable-sized unit is compact in size but it comes with a powerful 230VDC output that can be used for powering up energy saving light bulbs of up to 11W. The unit is designed with the flexibility to be powered by regular AC supply or via the supplied battery. The PROLiNK PBU unit’s potential is best realized for users that commonly experience power blackouts. The unit is also brilliantly designed to allow a range of flexible display methods: vertically or horizontally standing, wall-mounted or as a portable display; as well as a choice to select between a B22 or E27 light bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective solution for your lighting requirements. • DC-powered outlets for 11watts energy saving bulb • 3 sets DC-powered outlets for energy saving light bulbs • Off mode charging • Overload protection in battery mode and short circuit protection • LED indication • 3-step charging design for extended battery life Backup Time Table: 11W Safe Energy Light Bulb x 1 no Up to 6 hours 11W Safe energy light bulb x 2 nos Up to 3 hours 11W Safe energy light bulb x 3 nos Up to 2 hours 11W Safe energy light bulb x 4 nos Up to 1.5 hours Full Specifications MODELS PBU5022 / PBU5027 Rated Power 50VA INPUT Voltage Voltage Range 220VAC 100VAC – 300VAC OUTPUT Output Voltage (AC Mode) 2-pin Sockets Output Voltage (Batt. Mode) Waveform BATTERY & CHARGER Battery Type and Number Battery Voltage Typical Recharge Time 230VDC 160-230VDC ± 10% DC Output 230 VAC 12V 7Ah x 1 12VDC Back to 90% capacity in 6 hours INDICATORS AC Mode – Green Lighting Battery Mode – Yellow Lighting LED Display Output Short-circuited – Red Lighting Charging Mode – Green flashing every 2 seconds Low Battery – Yellow flashing every second Overload – Red Flashing every 0.5 seconds Red LED staying on for one second and off for 4 seconds PROTECTION Full Protection Overload Protection and short circuit protection PHYSICAL Dimension, D X W X H (mm) Net Weight (kgs) 209 x 87 x 200 2.7 OPERATING ENVIRONMENT Operating Temperature Humidity 0°C to 40°C 0-90% relative Humidity (Non-condensing) PBU5022 = for B22 light bulb terminal. PBU5027 = for E27 light bulb terminal. *All specifications, designs and contents are subject to change without prior notice. B22 Connector E27 Connector 76 Solar PROLiNK Solar Inverter Zonne Series PROLiNK Zonne 450 unit is a compact and user-friendly solar power unit that is suitable for use in home like settings. The Zonne series is designed with a built-in charger controller that facilitates proper charging of the battery; enhancing the overall lifespan of the battery. Also, the PROLiNK Portable Solar unit comes with the flexibility to be powered by regular AC supply, solar PV modules or via the supplied battery. The Zonne unit is capable of supporting up to one block of 100AH battery, giving users ample amount of power supply to operate multiple home appliances. • 450W Inverter • PWM technology solar charger • Off mode charging • Overload protection and short circuit protection in battery mode • Universal socket Home Appliance External Battery Utility Supply Solar Panel Backup Time Table: Battery Type 1 block x 12V40AH Battery Type 1 block x 12V65AH Effective Sunshine Duration 5 hours Effective Sunshine Duration 5 hours Application / Load Battery back-up 2 x energy saving light bulb 8 hours per day 1 x energy saving light bulb 1 x Fan 2 x energy saving light bulb 1x Fan 6 hours per day 4 hours per day Application / Load Battery back-up 2 x energy saving light bulb 10 hours per day 1 x energy saving light bulb 1 x Fan 2 x energy saving light bulb 1x Fan 8 hours per day All specifications, designs and contents are subjected to changes without prior notice. The above Battery back-up calculation is based on estimated values and will be subject to change (Variables include; load consumption, sunshine duration and PV panel peak power supply). 6 hours per day 77 Solar Full Specifications MODELS Zonne 450 Rated Power AC INPUT Voltage 450W 220/ 230/ 240VAC Voltage Range 162 - 290VAC (UPS Mode) 90 or 280VAC (INV. Mode) OUTPUT Output Voltage Voltage Regulation (Batt.Mode) Waveform BATTERY & CHARGER Battery Voltage Floating Voltage Maximum Charge Current 230VAC ±10% Simulated Sinewave 12VDC 13.4VDC ± 1.5% 10Amp PROTECTION Full Protection Overload and Short Circuit Protection INDICATORS Line Mode Battery Mode Green Lighting Yellow Lighting Low Battery Yellow Flashing every 2 seconds Shutdown Mode Yellow Flashing every 5 seconds Charging Mode at Power On Green Flashing every 2 seconds Charging Mode at Power Off Overload Green Flashing every 5 seconds Red Flashing for 0.5sec. every seconds Overcharging Fault Red Flashing every 5 seconds Red lighting SOLAR CHARGER Charging Current 10Amp System Voltage 12VDC PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) *All specifications, designs and contents are subjected to changes without prior notice. *Above mentioned Back-up timetable is for reference purpose only. 293 x 231.5 x 82.5 2.35 78 Solar PROLiNK PORTABLE SOLAR PPS Series PROLiNK Portable Solar (PPS) unit is a compact and user-friendly lighting solar power supply unit that is suitable for use in home / outdoor settings. This portable-sized unit is compact in size but it can be used for powering up energy saving light bulbs of up to 11W. In addition, there is also a 5VDC USB port for charging your mobile devices and a 12VDC round pin connector for equipment such as DC fans. PROLiNK Portable Solar unit provides you the option of doubling up your backup duration by adding another block of 7AH battery on top of the existing supplied battery. The PPS is the perfect device for users living in rural locations where the power supply is often inconsistent and unstable. PPS70M PPS70 PPS70 • DC-powered outlets for 11watts energy saving bulb • 3 x 5V USB charging ports for mobile phones • PWM technology solar charger • Off mode charging • Overload and short circuit protection in battery mode • 12VDC round pin connector output for 12VDC equipment • Option for lamp holder with 2m cable • Option for 24W Solar PV panel 3 Outlet For Energy Saving Bulb 12VDC Supply Mobile Phone Utility Supply Solar External Battery PPS70M • 11W DC UPS • Built-in 3 watts LED. • 12VDC-powered outlets for 11watts energy saving bulb • 1 x 5V USB charging ports for mobile phones • PWM technology solar charger • Off mode charging • Overload and short circuit protection in battery mode • Lamp holder with 5m cable • 16W Solar PV panel 1 Outlet For 3watt LED Light Bulb Solar Mobile Phone 79 Solar Full Specifications MODELS PPS70M PPS70 PV INPUT Maximum PV Array Open Circuit Voltage Maximum Solar Charging Current 30VDC 1A 2A AC INPUT Voltage 230VAC Frequency Range Not Applicable 50 Hz or 60 Hz (auto sensing) OUTPUT Output Voltage (AC Mode) 2-pin Sockets Output Voltage (Batt. Mode) 230VDC Not Applicable 160-230VDC ± 10% Waveform 12VDC DC Output DC Connector USB Charger 12VDC 2A x 1 pc Not Applicable 5VDC 1A x 3 pcs 5VDC 1A x 1 pc Not Applicable 3W LED LIGHT (Built-in) Power BATTERY & CHARGER Battery Type and Number Battery Voltage Typical Recharge Time 12V 7Ah x 1 (Optional external battery) Not Applicable 12VDC Back to 90% capacity in 8 hours Back to 90% capacity in 4-6 hours PROTECTION Full Protection Overload Protection and short circuit protection PHYSICAL Dimension, D X W X H (mm) Net Weight (kgs) 229 x 110 x 123.5 3.8 OPERATING ENVIRONMENT Operating Temperature 0°C to 40°C 0-90% relative Humidity (Non-condensing) Humidity *All specifications, designs and contents are subject to change without prior notice. 80 Solar PROLiNK Solar System PCC Series PCC Series is a Solar Installation System that combines the benefits of both the Maximum Power Point Tracking (MPPT) technology and DSP controller system. The MPPT enhances the PCC Series by transferring the most power from its PV solar modules and the DSP controller system provides a high level of computational performance for real-time signal processing in the solar power inverters. This allows your solar panels to operate at their optimum power output voltage, thereby increasing the level of efficiency to 97.7% and at the same time lowering power loss. Users can start generating green energy for their home applications by integrating the PCC Series with solar panels, inverter and external battery packs. Batteries are compatible with up to 4 types; sealed lead acid, vented, gel and NiCad. • Intelligent Maximum Power Point Tracking technology • Built-in DSP controller with high performance • Automatic battery voltage detection • Multi-functional LCD • Reverse polarity protection for solar panel and battery • Overcharge and overload protection • Suitable for battery types such as sealed lead acid, vented Gel and NiCd • Standard RJ45 port or optional RS-485 communication port for remote monitoring PCC300 Solar Panel Inverter External Battery Packs Home Appliances *All specifications, designs and contents are subject to change without prior notice. 81 Solar Full Specifications MODELS INPUT MPPT Range @ Operating Voltage Maximum PV Array Open Circuit Voltage PCC300 PCC600 15 ~ 33V @ 12V 30 ~ 66V @ 24V 50V 75V Maximum Array PCC3000 60 VDC ~ 115 VDC 145VDC Maximum PV Array Power Maximum Current 800W 18A 1600W 3200W 50A OUTPUT Nominal Battery Voltage 12V 24V Connected Battery Type Maximum Charging Current 12V 24V 48V Sealed Lead Acid, Vented, Gel, MiCd Battery 25A 60A Ripple Voltage <±1V Maximum Efficiency Stanby Power Consumption 98% 98% 1W 2W Charging Method Three Stages: Bulk, Absorption & Floating PROTECTIONS Overload Protection >110%: Audiable Alarm INDICATION LCD Panel Yes Yes Yes Overcharge Protection Polarity Reversal Protection @ Solar Cell & Battery LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions Three indicators: Solar, Charging & Load Status LED Display Three indiators: Solar, Battery & Wiring Fault PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) Connector 135 x 170 x 57.5 0.92 220 x 170 x 57.5 1.85 Input or Output Terminal Block 315 x 165 x 128 4.5 IP43 IP31 0~90% Relative Humidity (Non-condensing) 5~95% Relative Humidity (Non-condensing) Type of Mechanical Protection ENVIRONMENT Humidity Operating Temperature -20°C to 55°C Storage Temperature -40°C to 75°C Altitude 0 ~ 3000m *All specifications, designs and contents are subject to change without prior notice. 82 Solar PROLiNK Solar System PSI Hybrid HYBRID Series PSI Hybrid Series is a hybrid inverter that combines the solar power system, AC utility and battery power source to supply continuous power to your home / office applications. This device is most suitable for rural areas where electrical supply is unstable and inconsistent. The PSI Hybrid series comes with a grid-tie operation mode where surplus electricity can be fed back to the main grid, making it an economic and cost-effective power option. If gaining access on the grid is not possible, the PSI Hybrid Series also comes with an off-grid operation mode where power can be stored directly to the back-up battery; making the Hybrid series one of most versatile solar inverters in the market. • Works as an On-grid inverter during the day • Works as an Off-grid inverter during the night or rainy conditions • Pure sine wave output • Multiple operations: Grid tie, Off grid, and grid-tie with backup • Built-in MPPT solar charger • LCD display panel for comprehensive information Full Specifications MODELS HYBRID 3K HYBRID PRO 3K Single Phase Phase PV INPUT Maximum DC Voltage MPP Voltage Range DC Nominal Voltage Start-up Voltage / Initial Feeding Voltage Maximum Input Current HYBRID 10K Three Phase 500VDC 900VDC 250 VDC ~ 450VDC 400 ~ 800VDC 360VDC 720VDC 116VDC / 150VDC 320VDC / 350VDC 13A 18A 18.6A x 2 GRID/ UTILITY INPUT (AC) Phase Single Phase Nominal AC Voltage/ Range Acceptable Voltage Range Maximum Input Current Three Phase 208/ 220/ 230/ 240VAC 400VAC 170 ~ 280VAC 170 - 280VAC 30A 25A GRID OUTPUT (AC) Nominal AC Voltage/ Range 220VAC / 184~265VAC AC Grid Frequency Range Nominal Output Current Power Factor BATTERY MODE OUTPUT (AC) Output Voltage 13A 14.5A >0.99 - 202/ 208/ 220/ 230/ 240VAC 400VAC 50Hz / 60Hz (auto sensing) Output Frequency Pure Sinewave Output Waveform Efficiency (DC to AC) 400VAC / 320~460VAC 47.5 ~ 50.2Hz 93% 96% BATTERY & CHARGE Nominal DC Voltage Maximum Charging Current 25A 200A PHYSICAL Dimension (mm) D x W × H 107 x 438 x 480 622 x 500 x 167.5 15.5 45 Net Weight (kgs) 48VDC INTERFACE Communication Port Intelligent Slot RS-232 / USB Optional SNMP, Modbus and AS-400 cards available ENVIRONMENT Operation Humidity Operating Temperature 0~90% (Non-condensing) 0°C~40°C Altitude -10°C to 55°C 0 ~ 1000m ** Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details. *All specifications, designs and contents are subject to change without prior notice. 83 Solar PROLiNK Solar System PSI On-Grid AMNETZ Series PSI On-Grid Series is a grid-connected photovoltaic power system that is designed to operate at its optimum power output voltage even under unfavourable weather conditions. This device uses high quality Amnetz PV inverters to convert DC to AC power at a maximum conversion efficiency of up to 96%. On top of that, this user-friendly device is bundled with a monitoring software kit that allows users to observe from a graphical overview of the module voltage/current and temperature. • 1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter • Advanced DSP control technology delivers accurate data • Smart MPPT technology enhances overall efficiency • Modular design for easy maintenance • Industrial-grade components used for robust operation • Up to 15 years of data logging • Ingress Protection rated 65 (good for any type of environmental conditions) • Comprehensive LCD monitor for easy-reading • Free monitoring software Full Specifications MODELS Phase AMNETZ 1500 INPUT (DC) Maximum DC Voltage MPP Voltage Range 450VDC 500VDC 150 ~ 400VDC 200 ~ 450VDC Nominal DC Voltage Start-up Voltage/ Initial Feeding Voltage Maximum Input Current/ Per String OUTPUT (AC) Nominal AC Voltage AMNETZ 2000 AMNETZ 3000 1 Phase-In 1 Phase-Out AMNETZ 10K** 3 Phase-In 3 Phase-Out 500VDC 500VDC 900VDC 320 ~ 800VDC 150 ~ 500VDC 360VDC 370VDC 600VDC 120/ 150VDC 125/ 150VDC 250/ 250VDC 11A 230VAC 230VAC 13A 2 x 15A 2 x 17A / 17A 230VAC 230VAC 3/ N/ PE, 230/ 400VAC AC Voltage Range 184 - 264VAC* AC Grid Frequency 50Hz / 60Hz Nominal Output Current AMNETZ 5000 6.6A 8.7A Power Factor -20% ~ +15%* 20A 13A 14.5A >0.99 EFFICIENCY Maximum Efficiency 96.0% 97% 98.0% PROTECTION DC Reverse-Polarity Protection Yes Ground Fault Monitoring Grid Monitoring Yes Yes AC Short Circuit Protection Yes PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 136.5 x 268.5 x 410 160 x 270 x 450 182 x 308 x 515 171.2 x 503.5 x 653.3 11.5 15 20 40 INTERFACE Intelligent Slot ENVIRONMENT Humidity USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards 0 ~ 100% Relative Humidity (nNon-condensing) Operating Temperature Altitude -25 ~ 60°C -25 ~ 60°C 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m) COMPLIANCE Standard CE, VDE-AR-N 4105, VDE-0126-1-1, IEC62109 *All specifications, designs and contents are subject to change without prior notice. **Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details. 84 Solar PROLiNK Solar System PSI Off-Grid HAUS Series The PSI HAUS Series is a wall-mounted off grid PV inverter that employs a PWM technology. It is best used in remote locations without utility services. The device is able to supply generous amount of electrical power to the load via PV modules, battery sources and AC powered sources. The HAUS Series is able to fully utilize the energy from the sun to convert stable electrical power to any home / commercial applications. In the event where it is inapplicable to draw power from PV modules and battery sources, an AC power source can still be supplied by a generator to get you through a rainy day. • Pure sine wave inverter • Selectable input voltage range • Selectable charging current • Utility or Solar input priority configuration via LCD setting • Generator compatible • Auto restart while AC is recovering • Overload and short circuit protection • Cold start function • Optional N+1 parallel redundancy Full Specifications MODELS HAUS 1000 HAUS 2000 HAUS 3000 HAUS 4000 HAUS 5000 Rated Power 1kVA / 800W 2kVA / 1.6kW 3kVA / 2.4kW 4kVA / 3.2kW 5kVA / 4kW INPUT Voltage 230VAC 170 - 280VAC (For Personal Computers) 90 - 280VAC (For Home Applicances) Selectable Voltage Range Frequency Range 50 Hz / 60 Hz (Auto Sensing) OUTPUT AC Voltage Regulation (Batt. Mode) Surge Power 230VAC ± 5 % 2000VA 4000VA 6000VA Efficiency (Peak) 8000VA 10000VA 93% Transfer Time 10 ms (For Personal Computers) Waveform Pure sine wave BATTERY Battery Voltage Floating Charge Voltage Overcharge Protection Maximum Charge Current 12VDC 24VDC 48VDC 13.5VDC 15VDC 10A or 20A 27VDC 30VDC 20A or 30A 54VDC 60VDC 20A or 30A 30VDC 60VDC SOLAR CHARGER (OPTION) 50A Charging Current Maximum PV Array Open Circuit Voltage 90VDC PHYSICAL Dimension, D X W X H (mm) Net Weight (kgs) 95 x 240 x 316 5.0 100 x 272 x 355 6.4 6.9 120 x 295 x 468 9.8 OPERATING ENVIRONMENT Humidity 5% to 95% Relative Humidity (Non-condensing) Operating Temperature Storage Temperature *All specifications, designs and contents are subject to change without prior notice. 0°C to 55°C -15°C to 60°C 85 Solar PROLiNK Solar System PSI Off-Grid HAUS MPPT Series HAUS 1KM/ 1KMHDC/ 2KM/ 3KM/ 3KMHDC HAUS 4KMHDC/ 5KMHDC HAUS PLUS 2KM/ 2KMHDC/ 3KM/ 3KMHDC The PSI HAUS MPPT Series is a wall-mounted off grid PV inverter that employs a MPPT technology. It is best used in remote locations without utility services. The device is able to supply generous amount of electrical power to the load via PV modules, battery sources and AC powered sources. The HAUS MPPT Series is able to fully utilize the energy from the sun to convert stable electrical power to any home / commercial applications. In the event where it is in applicable to draw power from PV modules and battery sources, an AC power source can still be supplied by a generator to get you through a rainy day. • Pure sine wave inverter • Built-in MPPT solar charge controller • Selectable input voltage range for home appliances and personal computers • Selectable charging current based on applications • Configurable AC/Solar input priority via LCD setting • Compatible to mains voltage or generator power • Auto restart while AC is recovering • Overload and short circuit protection • Smart battery charger design for optimized battery performance • Cold start function • Parallel operation with up to 6 units only available for 4KVA/5KVA • Optional Remote Control Panel available 86 Solar Full Specifications MODELS Capacity HAUS 1KM HAUS 1KMHDC HAUS 2KM HAUS 3KM HAUS 3KMHDC HAUS 4KMHDC HAUS 5KMHDC 1000VA/ 800W 1000VA/ 800W 2000VA/ 1600W 3000VA/ 2400W 3000VA/ 2400W 4000VA/ 3200W 5000VA/ 4000W INPUT Voltage 230 VAC 170-280 VAC (For Personal Computers) 90-280 VAC (For Home Appliances) Selectable Voltage Range Frequency Range 50/60 Hz (Auto sensing) OUTPUT AC Voltage Regulation (Batt. Mode) 230VAC ± 5% Surge Power 2000 VA Efficiency (Peak) 4000 VA 6000 VA 90% - 93% Transfer Time 8000 VA 10000 VA 93% 10 ms (For Personal Computers); 20 ms (For Home Appliances) Waveform Pure sine wave BATTERY & AC CHARGER Battery Voltage 24 VDC 48 VDC 24 VDC 48 VDC Floating Charge Voltage 27 VDC 54 VDC 27 VDC 54 VDC Overcharge Protection 31 VDC 62 VDC 31 VDC 600 W 900 W 62 VDC 60 VDC SOLAR CHARGER & AC CHARGER Maximum PV Array Power MPPT Range @ Operating Voltage Maximum PV Array Open Circuit Voltage Maximum Solar Charge Current Maximum AC Charge Current Maximum Charge Current 30VDC ~ 66VDC 60VDC ~ 88VDC 600 W 900 W 3000 W 30VDC ~ 66VDC 60VDC ~ 88VDC 60VDC ~115VDC 75 VDC 102 VDC 75 VDC 102 VDC 145 VDC 25A 20A 18A 15A 25A 30A 18A 15A 60A 60A 18A 30A 18A 120A 25A AC charger and solar charger can’t work at the same time. Maximum Efficiency 98% Standby Power Consumption 2W 120A PHYSICAL 100 x 272 x 355 Dimension, D x W x H (mm) Net Weight (kgs) 6.8 120 x 295 x 468 7.0 7.4 11 ENVIRONMENT Humidity 5% to 95% Relative Humidity(Non-condensing) Operating Temperature 0°C - 55°C Storage Temperature MODELS Inverter Power Pmax. Generated From Solar Charger Best Panel Configuration -15°C - 60°C HAUS 1KM HAUS 1KMHDC HAUS 2KM HAUS 3KM HAUS 3KMHDC 800W 1000W 1600W 2400W 2400W 25Amp, 600W 20Amp, 900W 25Amp, 600W 25Amp, 600W 20Amp, 900W HAUS 4KMHDC HAUS 5KMHDC 3200W 4000W 60Amp, 3000W 60Amp, 3000W 500Wp 1000Wp 500Wp 500Wp 1500Wp 3000Wp 3000Wp (250Wp x 2pcs) (250Wp x 4pcs) (250Wp x 2pcs) (250Wp x 2pcs) (250Wp x 6pcs) (250Wp x 12pcs) (250Wp x 12pcs) 87 Solar MODELS HAUS PLUS 2KM HAUS PLUS 2KMHDC HAUS PLUS 3KM HAUS PLUS 3KMHDC Capacity 2000VA/ 800W 2000VA/ 1000W 2000VA/ 1600W 3000VA/ 2400W INPUT Voltage Selectable Voltage Range 120 VAC or 230 VAC 230 VAC 95-140 or 170-280 VAC (For Personal Computers) 65-140 or 90-280 VAC (For Home Appliances) 170-280 VAC (For Personal Computers) 90-280 VAC (For Home Appliances) Frequency Range 50/60 Hz (Auto sensing) OUTPUT AC Voltage Regulation (Batt. Mode) 110/120 VAC ± 5% (User Selectable) or 230VAC ± 5% 230VAC ± 5% 4000 VA 6000 VA Surge Power Efficiency (Peak) 90% - 93% Transfer Time 10 ms (For Personal Computers); 20 ms (For Home Appliances) Waveform Pure sine wave BATTERY & AC CHARGER Battery Voltage 24 VDC 48 VDC 24 VDC 48 VDC Floating Charge Voltage 27 VDC 54 VDC 27 VDC 54 VDC Overcharge Protection 31 VDC 62 VDC 31 VDC 62 VDC SOLAR CHARGER & AC CHARGER Maximum PV Array Power MPPT Range @ Operating Voltage 1500 W 3000 W 1500 W 3000 W 30~115 VDC or 60~115 VDC 60~115 VDC 30~115 VDC or 60~115 VDC 60~115VDC Maximum PV Array Open Circuit Voltage 145 VDC Maximum Solar Charge Current Maximum AC Charge Current 60A 20A or 20A / 30A 10A or 10A / 15A 20A 30A Maximum Efficiency 98% Standby Power Consumption 2W 10A / 15A PHYSICAL 140 x 295 x 479 Dimension, D x W x H (mm) Net Weight (kgs) 11.5 ENVIRONMENT Humidity 5% to 95% Relative Humidity(Non-condensing) Operating Temperature 0°C - 55°C Storage Temperature -15°C - 60°C HAUS PLUS 2KM MODELS Inverter Power HAUS PLUS 2KMHDC HAUS PLUS 3KM 60Amp, 3000W 1500Wp (250Wp x 6pcs) 60Amp, 1500W 1600W Pmax. Generated From Solar Charger Best Panel Configuration 60Amp, 1500W There are charging current selection only available for 230VAC system. *All specifications, designs and contents are subject to change without prior notice. HAUS PLUS 3KMHDC 1600W 60Amp, 3000W 3000Wp (250Wp x 12pcs) 88 Software & Accessories PROLiNK Online UPS Accessories External Battery Charger (PEC) PROLiNK External Charger (PEC) is an additional external smart charger for PROLiNK Online UPS system. It designed with isolation structure and operated in parallel with several units for charging capability expandable. • Input PFC control • Back feed protection • Three-stage smart charging • Short circuit and over voltage protection • Maximum current restriction • Redundancy operation With PROLiNK External Battery Cabinet UPS Expandable Charger units With External Battery Bank Expandable PROLiNK battery cabinets UPS Expandable Charger units Expandable battery units Full Specifications MODELS PEC20-24 PEC15-36 PEC15-48 INPUT Nominal Voltage PEC12-72 PEC10-96 PEC24-240 230VAC 170~280VAC Voltage Range Nominal Frequency 110~300VAC 50/60Hz 8A Input Current (max) @ full load 60A OUTPUT Nominal Voltage Output Current (max) Floating Charging Voltage 24VDC 36VDC 20A 48VDC 72VDC 96VDC 12A 10A 24A 82.2VDC 109.6VDC 273.6VDC 15A 27.3VADC 41.1VDC 54.8VDC 240VDC EFFICIENCY AC Mode Up to 85% PROTECTION Full Protection Over-voltage, Thermal control, Over current, Short circuit, Reversal polarity INDICATION Charger ON – Green LED LED Display Boost Charging Status – Yellow LED Floating Charging Status – Green LED N/A Low Charging Voltage – Red LED PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 300 x 177 x 90 570 x 250 x 215 3.1 14 ENVIRONMENT Relative Humidity Operation Temperature Noise Level IP Class <95% (Non-condensing) 0 ~ 40°C <50dB IP20 All specifications, designs and contents are subjected to changes without prior notice. 89 Software & Accessories PROLiNK Online UPS Accessories Automatic Transfer Switch PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the connected load. In the event where the primary power source fails, the ATS automatically transfers the backup connection to the secondary power source without any interruption, providing seamless electrical power and the highest protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection back to the primary power source once it has detected restored power. • 16A maximum input current • Powered by two separate independent power sources • Dual power supply for redundancy • Provides seamless power switch for IT equipment • Preferred source selection on front panel • 19” rack-mount design (1U) • Built-in USB and RS-232 interface Full Specifications MODELS ATS16-R Current Rating INPUT Input Voltage Acceptable Input Voltage Input Frequency 16A 230VAC 207 ~ 253VAC 50Hz/ 60Hz OUTPUT Output Voltage Maximum Output Current 230VAC 10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets CONNECTION 2xIEC-C20 Inlets Input Output 8xIEC-C13; 1xIEC-C19 Communication Transfer Time PHYSICAL Dimension (mm) D x W x H Net Weight (kgs) USB/ RS-232 9 ~ 12ms (Typical) 310 x 430 x 44 3.65 ENVIRONMENT Operating Temperature *All specifications, designs and contents are subject to change without prior notice. 20 ~ 95% Relative Humidity @ -5°C ~ 45°C (Non-condensing) 90 Software & Accessories PROLiNK Online UPS Accessories PDU & Maintenance Bypass Switch The PDU & Maintenance Bypass Switch is an external power distribution unit used in conjunction with UPS systems or large-scale voltage regulators. This device enables the UPS to be isolated for scheduled maintenance or replacement without interrupting the power to the load. Designed with a master-controller concept, the PROLiNK PDU is able to handle both the maintenance bypass function and power saving function effectively. • 16A for 208/220/230/240 VAC • Provides continuous power to connecting equipment during UPS maintenance • Easy operation with simple rotary switch and indicators • Master-slave function for energy saving • Multiple sockets to support more devices • Choose between a rack or tower design to fit into any working environment • Simple installation with plug-and-play socket type • Suitable for all UPSs up to 3kVA IEC UK Schuko NEMA Full Specifications MODELS MBS16-R (I/U/S/N) (*) MBS16-T (I/U/S/N) (*) Current Rating 16A Voltage Rating 208/ 220/ 230/ 240/VAC Master/ Slave Function Yes. When power consumption in Master Outlet is lower than 20W (±5W), it will shut off the power for slave outlets. NA CONNECTION 1 x IEC (16A) Connector & 1 x Customized Plug Cable AC Power Input UPS Input UPS Output IEC Output 1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k) 5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers) 8 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers) Schuko 4 x Schuko 16A Sockets 4 x UK 13A Sockets UK 5 x NEMA 20A Sockets 6 x NEMA 20A Sockets IEC 80 x 438 x 50 180 x 160 x 50 Schuko UK 80 x 438 x 60 180 x 200 x 50 NEMA 80 x 438 x 50 180 x 160 x 50 1.50 1.30 NEMA PHYSICAL Dimension (mm) DxWxH Net Weight (kgs) ENVIRONMENT Operating Temperature I = IEC, U = UK, S = EU, N = Nema *All specifications, designs and contents are subject to change without prior notice. 20 ~ 95% Relative Humidity @ -0°C ~ 40°C (Non-condensing) 91 Software & Accessories PROLiNK Online UPS Accessories SNMP Card Integrated with our latest ViewPower software, the SNMP manager operates as an enhanced communication solution for your UPS system. It allows you to remotely manage and monitor your UPS system via internet connectivity. Once connected to the internet, the ViewPower software provides you access to remotely program or even shut down your UPS system. • Allows control and monitoring of multiple UPSs through RJ-45 network connection • Real-time dynamic graphs reflecting UPS data (Voltage, frequency, load level and battery level) • Warning notifications via audible alarm, broadcast, mobile messenger, e-mail and SNMP traps • Historical data logging • One click easy firmware upgrade • Password security protection and remote access management • Supports optional environmental monitoring detector for temperature, humidity and smoke Modbus Card The ModBus Card provides UPS and PV inverter systems with the functionality to communicate with PCs through the ModBus Protocol. • Adopts ModBus RTU Protocol • Comes with functions that includes read Holding Registers and write Registers • RS232 and RS485 interface AS-400 Card The AS-400 communication card is designed with a high quality contact closure board that accurately converts UPS signals into dry contacts for users to monitor UPS events that are most concerned to them. By setting the jumper, the AS-400 communication card allows you to select various status indicators such as; UPS alarm, UPS failure, Bypass, Low Battery etc. • Capable of selecting the status of the dry-contact signal by setting the jumper to meet different application requirements • Suitable applications include; IBM Server, Personal PC & Workstations equipments, Auto-controlled industrial equipment & communication applications Rack Mount Slider The PROLiNK Rack-mount slider kit offers you the best solution to install a PROLiNK UPS system into a 19” server rack enclosure. This kit comes with a pair of heavy duty sliders that are attached with quality assured ball bearings to ensure that your server can slide effortlessly into and out of the rack. Furthermore, the PROLiNK Rack-mount slider kit includes a superior quality front and rear mounting brackets to withstand the weight of your UPS. • Simple and easy installation • Suitable for PROLiNK Rack Mount Online UPS system • Slider length available in 700mm and 1100mm to suit different types of cabinet 92 Software & Accessories PROLiNK Online UPS Software Viewpower – UPS Management Software ViewPower is an advanced UPS management software that is designed for users to remotely monitor and manage multiple UPS units in a networked environment, either by LAN or INTERNET. The ViewPower software is able to protect your important data by executing a safety OS shutdown during power failure. Better yet, this software gives users the ability to store programming data and also scheduled a UPS shutdown when necessary. • Allows control and monitoring of multiple UPSs via LAN and INTERNET • User-friendly power analysis graphs • Real-time dynamic graphs of UPS data • Safety OS shutdown to prevent data losses during power failure • Warning notifications via audible alarm, broadcast, mobile messenger, and e-mail • Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control • Password security protection and remote access management • Supports multiple OS and local languages Solar Power Management Software SolarPower Pro is a solar inverter monitoring software that is capable of monitoring up to 247 devices via a modbus interface. When connected to a networking environment, users are able to monitor the Solar inverter via a web browser. The SolarPower Pro comes with a variety of features including; data logging, ability to generate statistical data, alarm notifications, prompting fault messages and parameter control for devices. • Allows control and monitoring of multiple devices via LAN and INTERNET • Automatic and real-time data acquisition • Secure data logging • Graphic display of device data for quick and easy reading • Warning notifications or fault alarms via audible alarm, pop-up screen, broadcast, mobile messenger, tray message and e-mail • Easy diagnosis from event statistics and amount calculation for energy saving • Maximum data log up to 10 billion records • Supports online upgrade and manually upgrade • Supports multiple languages: English, Chinese, French, German, Spanish, Russian, Portuguese, Ukrainian, Italian, Polish 93 Appendix PROLiNK UPS Battery Backup Configuration List 1. Professional Series (1P/1P) - Tower BACK UP TIME POWER RATING BATTERY GROUP DC BUS (VDC) 15 MINUTES 30 MINUTES 1 HOUR 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY C6*1 12V65AH*6 PEC20-24*1 C8*1 12V65AH*8 PEC20-24*1 C12*1 12V65AH*12 PEC15-48*1 C20*1 12V65AH*18 PEC12-72*1 C16*1 12V65AH*16 PEC15-48*1 C24*1 12V65AH*24 PEC12-72*1 C32*1 12V65AH*32 PEC10-96*2 C20*2 12V65AH*40 PEC10-96*3 PRO901L 2/24VDC C1*1 12V26AH*2 C1*1 12V17AH*4 C2*1 12V65AH*2 C3*1 12V100AH*2 PRO902L 4/48VDC C2*1 12V26AH*4 C2*1 12V17AH*8 C4*1 12V65AH*4 C4*1 12V100AH*4 PRO903L 6/72VDC C3*1 12V26AH*6 C3*1 12V17AH*12 C6*1 12V65AH*6 C6*1 12V100AH*6 PRO906L 8/96VDC C4*1 12V17AH*16 C8*1 12V26AH*16 C8*1 12V100AH*8 C24*1 12V65AH*24 PC96*1 REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 2. Master Series (1P/1P) - Tower BACK UP DC BUS TIME (VDC) POWER BATTERY RATING GROUP 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY PRO801L 3/36VDC C1*1 12V17AH*3 C1*1 12V26AH*3 C3*1 12V26AH*6 C3*1 12V65AH*3 C6*1 12V65AH*6 PEC15-36*1 C6*1 12V100AH*6 PEC15-36*1 PRO8015L 3/36VDC C1*1 12V26AH*3 C2*1 12V17AH*6 C3*1 12V65AH*3 C3*1 12V100AH*3 C6*1 12V100AH*6 PEC15-36*1 C12*1 12V65AH*12 PEC15-36*2 PRO802L 6/72VDC C2*1 12V17AH*6 C3*1 12V26AH*6 C6*1 12V26AH*12 C6*1 12V65AH*6 C20*1 12V26AH*36 PEC12-72*1 C12*1 12V100AH*12 PEC12-72*1 PRO803L 6/72VDC C3*1 12V26AH*6 C3*1 12V17AH*12 C6*1 12V65AH*6 C6*1 12V100AH*6 PEC12-72*1 C12*1 12V100AH*12 PEC12-72*1 C20*1 12V65AH*18 PEC12-72*1 PRO806L 20/240VDC C6*1 12V17AH*20 C12*1 12V26AH*20 C4*2 12V18AH*40 C20*1 12V26AH*40 PEC24-240*1 C20*1 12V100AH*20 PEC24-240*1 C20*2 12V65AH*40 PEC24-240*1 PRO810L 20/240VDC C12*1 12V26AH*20 C6*2 12V17AH*40 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*2 C20*3 12V65AH*60 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 3. Master Series (1P/1P) - 2-in-1 Rack/ Tower BACK UP TIME POWER RATING BATTERY GROUP DC BUS (VDC) 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY PRO801RL 2/24VDC G8R*1 12V7AH*8 C1*1 12V17AH*4 C2*1 12V65AH*2 C3*1 12V100AH*2 PEC20-24*1 C6*1 12V65AH*6 PEC20-24*1 C8*1 12V65AH*8 PEC20-24*1 PRO8015RL 3/36VDC G12R*1 12V7AH*12 C2*1 12V17AH*6 C3*1 12V65AH*3 C3*1 12V100AH*3 PEC15-36*1 C6*1 12V100AH*6 PEC15-36*1 C12*1 12V65AH*12 PEC15-36*2 PRO802RL 4/48VDC G20R*1 12V7AH*16 C2*1 12V17AH*8 C4*1 12V65AH*4 C4*1 12V100AH*4 PEC15-48*1 C12*1 12V65AH*12 PEC15-48*1 C16*1 12V65AH*16 PEC15-48*2 PRO803RL 6/72VDC G12R*2 12V7AH*24 C3*1 12V17AH*12 C6*1 12V65AH*6 C6*1 12V100AH*6 PEC12-72*1 C20*1 12V65AH*18 PEC12-72*1 C24*1 12V65AH*24 PEC12-72*2 PRO806RL 20/240VDC G20R*2 12V9AH*40 C12*1 12V26AH*20 C20*1 12V26AH*40 PEC24-240*1 C20*1 12V65AH*20 PEC24-240*1 C20*2 12V65AH*40 PEC24-240*1 C20*3 12V65AH*60 PEC24-240*1 PRO810RL 20/240VDC G20R*4 12V7AH*80 C20*1 12V26AH*40 C20*1 12V100AH*20 PEC24-240*1 C20*2 12V65AH*40 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*4 12V65AH*80 PEC24-240*1 The above battery backup configuration list is only applicable to the isolation transformer UPS version. All specifications, designs and contents are subjected to changes without prior notice. REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 94 Appendix 4. Master Series (3P/1P) - Tower BACK UP TIME POWER RATING BATTERY GROUP DC BUS (VDC) 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY PRO83110L 20 C12*1 12V26AH*20 C6*2 12V17AH*40 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*1 C20*3 12V65AH*60 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 PRO83115L 20 C6*2 12V17AH*40 C20*1 12V26AH*40 C20*1 12V100AH*20 C20*2 12V100AH*40 PEC24-240*1 C20*4 12V65AH*80 PEC24-240*1 C20*3 12V100AH*60 PEC24-240*1 PRO83120L 20 C12*2 12V26AH*40 C12*3 12V26AH*60 C20*2 12V65AH*40 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*6 12V65AH*120 PEC24-240*2 C20*4 12V100AH*80 PEC24-240*2 PRO83130L 20 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*3 12V100AH*60 PEC24-240*1 C20*5 12V100AH*100 PEC24-240*2 C20*7 12V100AH*140 PEC24-240*3 REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 5. Master Series (3P/1P) - Rack Mount BACK UP TIME POWER RATING BATTERY GROUP DC BUS (VDC) 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY PRO83110RL 20 G20R*3 12V9AH*60 C4*2 12V17AH*40 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*1 C20*3 12V65AH*60 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 PRO83120RL 20 C12*2 12V26AH*40 C12*3 12V26AH*60 C20*2 12V65AH*40 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*6 12V65AH*120 PEC24-240*2 C20*4 12V100AH*80 PEC24-240*2 REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 6. Master Series (3P/3P) - Tower BACK UP DC BUS TIME (VDC) BATTERY POWER GROUP RATING 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY PRO83310L 20 C12*1 12V26AH*20 C4*2 12V17AH*40 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*1 C20*3 12V65AH*60 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 PRO83315L 20 C6*2 12V17AH*40 C20*1 12V26AH*40 C20*1 12V100AH*20 C20*2 12V100AH*40 PEC24-240*1 C20*4 12V65AH*80 PEC24-240*1 C20*3 12V100AH*60 PEC24-240*1 PRO83320L 20 C12*2 12V26AH*40 C12*3 12V26AH*60 C20*2 12V65AH*40 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*6 12V65AH*120 PEC24-240*2 C20*4 12V100AH*80 PEC24-240*2 PRO83330L 20 C20*1 12V65AH*20 C20*1 12V100AH*20 PEC24-240*1 C20*2 12V100AH*40 PEC24-240*1 C20*3 12V100AH*60 PEC24-240*1 C20*5 12V100AH*100 PEC24-240*2 C20*7 12V100AH*140 PEC24-240*3 The above battery backup configuration list is only applicable to the isolation transformer UPS version. *All specifications, designs and contents are subject to change without prior notice. REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. 95 Appendix 7. Power Series (3P/3P) BACK UP TIME POWER RATING BATTERY GROUP DC BUS (VDC) 15 MINUTES 30 MINUTES 1 HOURS 2 HOURS 3 HOURS 4 HOURS QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY C16*2 12V17AH*124 C32*2 12V26AH*124 C32*2 12V100AH*62 C32*4 12V65AH*124 C16*1 12V17AH*62 PRO73315S 62 PRO73320S 62 C16*1 12V17AH*62 C32*1 12V26AH*62 C16*2 12V17AH*124 C32*2 12V65AH*62 C32*2 12V100AH*62 C32*4 12V65AH*124 PRO73330S 62 C32*1 12V26AH*62 C16*2 12V17AH*124 C32*2 12V65AH*62 C32*2 12V100AH*62 C32*6 12V65AH*186 C32*4 12V100AH*124 PRO73340S 62 C16*2 12V17AH*124 C32*2 12V26AH*124 C32*2 12V100AH*62 C32*4 12V65AH*124 C32*4 12V100AH*124 C32*8 12V65AH*248 PRO73360S 62 C32*2 12V26AH*124 C32*2 12V65AH*62 C32*4 12V65AH*124 C32*4 12V100AH*124 C32*6 12V100AH*186 C32*8 12V100AH*248 PRO73380S 62 C32*2 12V65AH*62 C32*2 12V100AH*62 C32*6 12V65AH*186 C32*8 12V65AH*248 C32*8 12V100AH*248 C32*10 12V100AH*310 PRO733100S 62 C32*2 12V100AH*62 C32*4 12V65AH*124 C32*4 12V100AH*124 C32*6 12V100AH*186 C32*10 12V100AH*310 C32*14 12V100AH*434 PRO733120S 62 C32*2 12V100AH*62 C32*4 12V100AH*124 C32*8 12V65AH*248 C32*8 12V100AH*248 C32*12 12V100AH*372 C32*16 12V100AH*496 REMARK 1. Without cable from UPS system to battery bank. 2. All batteries supply are without battery cables. Battery Configurations CABINET WEIGHT Available Battery Quantity CABINET DIMENSION (D * W * H) 100AH 65AH 38AH 24AH 17AH CI C2 435*210*270 450*470*320 1 1 1 2 2 4 3 4 5 10 12V7AH or 12V9AH or 10Ah / / C3 585*470*320 3 3 6 6 14 / 8kg C4 C6 450*470*615 585*470*615 4 6 4 6 8 12 8 12 20 28 / / 18kg 22kg C8 780*470*615 8 8 16 16 36 / 25kg C12 C16 780*470*900 780*470*1190 12 16 12 16 24 32 24 32 / 62 / / 32kg 45kg C20 950*470*1190 20 20 40 40 / / 45kg C24 C32 1150*470*1190 780*880*1190 24 32 24 32 / 62 / 62 / / / / 75kg 95kg MODEL NO REMARK 3.5kg 6kg 1. Option for DC switch/protection 2. Option for battery cable inter connection. For Power Series Included cables, without switch G6 6 Completed assembled G12 12 Completed assembled G18 G60 18 60 Completed assembled completed assembled G8R 8 Completed assembled G12R 12 Completed assembled G20R 20 Completed assembled The above battery backup configuration list is only applicable to the isolation transformer UPS version. *All specifications, designs and contents are subject to change without prior notice. 96 SINGAPORE FIDA INTERNATIONAL (S) PTE LTD Block 16 Kallang Place #06-02, Singapore 339156 Tel: (65) 6357 0668 MALAYSIA FIDA SYSTEMS (M) SDN BHD Tel: (60) 3 8024 9151 INDONESIA PROLiNK INDONESIA Tel: (62) 21 3483 1777 Technical Support Hotline: Singapore (65) 6357 0666 Malaysia (60) 3 8023 9151 Indonesia (62) 21 3483 1717 Operating Hours Monday - Friday: 9.00am - 6.00pm Closed on Saturdays, Sundays & Public Holidays