uninterruptible power supply (ups)

advertisement
Your Inspirations. Our Innovations.
UNINTERRUPTIBLE
POWER SUPPLY (UPS)
Protecting Your Data
CATALOGUE
2015 Revision 1.0
Table of Contents
Table of
Contents
About Us - Company Profile
02
Online UPS
04
Professional Series (1P/1P) - Tower
04
Professional Series (1P/1P) - Dual
06
Master Series (1P/1P) - Tower
08
Master E Series (1P/1P) - Tower
12
Master Series (1P/1P) - 2-in-1 Rack/ Tower
14
Master Series (3P/1P) - Tower
19
Master E Series (3P/1P) - Tower
22
Master Series (3P/1P) - Rack Mount
25
Master Series (3P/3P) - Tower
27
Master E Series (3P/3P) - Tower
29
Power Series
31
Power E Series
36
PPM Series
41
PRO-R Series
44
PRO-M Series
46
PRO-EM Series
49
Giant Series
52
Jupiter Series
54
Line Interactive UPS
58
PRO SFC Series
58
PRO SFT Series
60
PRO Series
62
PRO-L Series
64
PRO Rack/ Tower Series
66
Outdoor Line Interactive Series
68
Inverter UPS
70
Inverter Series
70
Auto Voltage Regulator
74
PVR Series
74
DC UPS
75
PDC Series
75
PBU Series
76
Solar UPS
77
Zonne Series
77
PPS Series
79
PCC Series
81
PSI Hybrid Series
83
PSI On-Grid Amnets Series
84
PSI Off-Grid Haus Series
85
PSI Off-Grid Haus MPPT Series
86
Software & Accessories
89
Appendix
94
01
About Us - Company Profile
Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products
manufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professional
experience in the information communications sector, PROLiNK is now renowned as a specialist in its field,
especially in the area of Back-up UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the
South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With
its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to
provide the right solutions to meet the needs of both home and business users within each geographical location
both efficiently and effectively.
The company’s quest for continuous improvement and quality assurance to its customers has earned us the
ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be
assured of they are getting true value - superior quality products at affordable prices.
Our Mission
Accentuate The Best For The E-generation
PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of
modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is
becoming more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind,
our products are crafted to enhance performance whether you are at work or play – our products work harder,
while you work smarter to achieve your desired results with less effort and better efficiency.
Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK.
With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable
solutions for their technological needs, while business users are assured of reliable and secure solutions for their
network infrastructure.
Our Vision
Ideas, Innovation and Information
PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing
and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas
of innovation, change and improvement so as to provide the next generation of users with products that are suitable for their technology advanced environments.
The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us
towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.
02
About Us - Company Profile
Core Values
Secured Information Management
With more than two decades of professional experience in providing backup power solutions to our customers, we
are able to support our customers with superior technological know-how and expertise, as well as advice on
market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to
manage confidential information discreetly.
Innovative Design
Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers.
With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet
functional, and suitable for each dynamic market that we have a presence in.
Superior Service Standards
Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item
meets our strict standards – from the individual components to the actual finished product.
Total Quality Assurance System
Our products go through careful planning and checks at every stage of the production cycle - from the beginning
stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that
our customers receive only the best quality goods – of high reliability and durability. Our total quality system has
been audited and approved by globally recognized bodies.
Range of UPS
The wide range of our products gives you an infinite range of solutions:
1. Online UPS
2. Line Interactive UPS
3. Inverter UPS
4. DC UPS
4. Solar UPS
03
Online UPS
Professional Series (1P/1P) - Tower
Online Professional Series
1kVA – 6kVA
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Servers
Professional Series (1P/1P) is an advanced yet affordable
single-phase UPS system that uses online double conversion
technology. It is designed to protect against power outages,
disturbances and spikes, making them most suitable for voltage
fluctuating environments. This device is able to provide
high-efficiency charging with its high input power factor correction.
Professional Series is available in capacities ranging from 1000VA to
6000VA. High voltage battery chargers and battery extension
assembly are made available for longer runtime applications. Users
can also have the option to top-up an additional isolation
transformer to obtain pure and clean power for their sensitive
devices.
•
•
•
•
•
•
•
•
•
True Double-Conversion Online UPS
Wide input voltage range (110~300VAC)
Input Power Factor correction of 0.98
Output Power Factor of 0.8
Generator compatible
LCD User Interface
Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface
Smart battery charger designed to optimize battery performance
Isolation transformer (optional)
Rear Panel
For 1kVA to 6kVA model
1.
2.
3.
4.
5.
6.
7.
8.
9.
Output receptacles
AC input
Input circuit breaker
Network/Fax Modem Surge Protection
Intelligent slot for communication port/
SNMP. (standard come with USB port)
External battery connection (only available for L model)
Output terminal
Output circuit breaker
Fan
5
5
4
5
6
9
1
PRO901S/L
PRO902S/L
3
9
1
7
6
8
8
9
4
3
2
4
6
1
2
7
2
PRO903S/L
PRO906S/L
04
Online UPS
Options
•
•
•
•
•
RS-232 Port (communication interface)
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection
Output Isolation Transformer
External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only)
Full Specifications
MODELS
PRO901S/ L
PRO902S/ L
PRO903S/ L
PRO906S/ L
Capacity
1000 VA
2000 VA
3000 VA
6000 VA
INPUT
Voltage Range
110-300 VAC ± 5 %
Frequency Range
40 ~ 70Hz (Auto sensing)
≧ 0.98 @ Nominal Voltage (100% load)
Power Factor
OUTPUT
Output Voltage
200/208/220/230/240 VAC or 100/110/115/120/127 VAC
Voltage Regulation (Batt. Mode)
±1%
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Synchronized Range)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Frequency Range (Batt. Mode)
Current Crest Ratio
3:1
Harmonic Distortion
≦ 3 % THD (Linear Load), ≦ 7 % THD (Non-linear Load)
Transfer Time
Zero
AC Mode to Batt. Mode
4 ms (Typical)
Inverter to Bypass
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
Up to 88%
AC Mode
BATTERY
Type
Standard Model
Valve regulated Lead Acid battery (Maintenance free batteries)
Capacity
9AH
Recharge Time (Typical)
Back to 90% capacity in 9 hours
10AH
Charging Current
1.0A (max)
Type
Long-Run Model
Depending on the application
Capacity
Charging Current
Depending on the application
1A / 2A / 4A / 8A (Default)
1A / 2A / 4A / 6A (Default)
OVERLOAD
100% < Load < 110%
Overload warning only (No shutdown)
110% < Load <130%
30 seconds
>130%
1.5 seconds
INDICATORS
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
LCD Display
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
17.2
397×145×220
Dimension (mm) D × W × H
Net Weight (kgs)
421 × 190 × 318
397 x 145 x 220
10.8
36.2
421×190×318
426×190×318
13.1
15.2
8.9
5.7
426 × 190 × 318
28.7
ENVIRONMENT
Operation Humidity
<90% (Non-condensing)
Ambient Temperature
0°C - +40°C
Noise Level
≤ 45dB @ 1 Meter
Regulations
Safety: EN62040-1-1; EMI62040-2; EN62040-3
< 55dB @ 1 Meter
MANAGEMENT
USB
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
05
Online UPS
Professional Series (1P/1P) - Dual
Online Professional Series
1kVA – 3kVA
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Servers
Professional Series (1P/1P) - Dual is an advanced yet affordable
single-phase UPS system that uses on-line double conversion
technology with 2 different input voltage ranges. It is designed to
protect against power outages, disturbances and spikes, making
them most suitable for voltage fluctuating environments.
Professional Series (1P/1P) – Dual is most suitable to be used in
areas that are plagued by voltages that are as low as 100V. With the
advanced double-conversion technology, the dual series is able to
regulate and maintain consistent output even when it is fully loaded.
Also, this device is able to provide full isolation and complete
common mode noise rejection from complementary equipment. The
Dual Series is available in various capacities, ranging from 1000VA
to 3000VA.
• True double-conversion
• Accepts dual input voltage for special power environment with High
Voltage and Low Voltage
• Complete galvanic isolation design offers full isolation and
complete common mode noise rejection
• Wide input voltage range (88-144VAC and 176-288VAC) at full load
• Selectable output voltage at 110VAC or 220VAC
• ECO mode for energy saving
• Input power factor correction 0.99
• Output voltage regulation < ± 1%
• Mini slot for USB / RS-232 / AS400 / SNMP communication
• Smart battery charger design for optimized battery performance
Rear Panel
5
For 1kVA to 3kVA model
1.
2.
3.
4.
5.
6.
7.
8.
9.
Output receptacles
AC input
Input circuit breaker
Network/Fax/Modem surge protection
Intelligent slot for communication port/SNMP
(standard come with USB port)
External battery terminal
(only available for Long-run model)
Output terminal
Output circuit breaker
Fan
5
4
4
5
6
9
4
6
9
1
9
1
3
9
2
8
6
1
9
2
7
2
9
9
9
PRO901DS/DL
PRO902DS/DL
PRO903DS/DL
06
Online UPS
Options
•
•
•
•
RS-232 Port (communication interface)
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection
External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only)
Full Specifications
MODELS
PRO901DS/DL
PRO902DS/DL
PRO903DS/DL
Capacity
1000 VA
2000 VA
3000 VA
INPUT
Nominal Voltage
110/115/120/127 VAC or 208/220/230/240 VAC (Auto sensing)
Voltage Range
88-144 VAC and 176 - 288 VAC (Auto sensing)
Frequency Range
45Hz ~ 55 Hz or 56Hz ~ 65 Hz
≧ 0.99 @ Nominal Voltage (100% Load)
Power Factor
OUTPUT
Output Voltage
110/115/120/127 VAC or 208/220/230/240 VAC
AC Voltage Regulation (Static)
± 1%
Frequency Range (Synchronized Range)
47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz
Current Crest Ratio
3:1
Harmonic Distortion
≦ 2 % THD (Linear Load) ; ≦ 6 % THD (Non-linear Load)
Zero
AC Mode to Battery Mode
Transfer Time
4 ms (Typical)
AC Mode to Bypass
Bypass to AC Mode
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY (Peak)
AC Mode (@100% RCD load)
76% (Typical); 78% (Peak)
77% (Typical); 79% (Peak)
78% (Typical); 80% (Peak)
Battery Mode(@100% RCD load)
ECO Mode
84% (Typical); 86% (Peak)
85%
86% (Typical); 88% (Peak)
88%
87% (Typical); 89% (Peak)
90%
BATTERY
Battery Type
Standard Model
Battery Numbers
12V / 9Ah
2
4
Recharge Time (Typical)
Charging Current
Charging Voltage
1.0A (max)
27.4 VDC ± 1%
54.8 VDC ±1%
Charging Current
Charging Voltage
82.2 VDC ±1%
Depending on application
Battery Type and Numbers
Long-Run Model
6
Back to 90% capacity in 5 hours
4A or 8A
27.4 VDC ± 1%
54.8 VDC ±1%
82.2 VDC ±1%
INDICATORS
UPS status, Load level, Battery level, Input / Output / battery info, Discharge timer, and Fault conditions
LCD Panel
ALARM
Battery Mode
Sounding every 4 seconds
Sounding every second
Low Battery
Sounding twice every second
Overload
Continously sounding
Fault
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
423 x 145 x 332
26.5
426 x 190 x 448
34
426 x 190 x 448
56
Dimension (mm) D × W × H
423 x 145 x 332
426 x 190 x 448
426 x 190 x 448
21.5
23
41
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
20-95 % RH @ 0- 40°C (Non-condensing)
Noise Level
Less than 50dBA @ 1 Meter
MANAGEMENT
Communication
Optional SNMP
RS232 Card / Optional USB Card, SNMP Card, or AS400 Card
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
07
Online UPS
Master Series (1P/1P) - Tower
Online Master Series
1kVA – 10kVA
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Servers
Master Series (1P/1P) is a single-phase UPS system that employs a true
online double-conversion technology. It is designed to deliver clean and
high quality electrical power for devices such as small computer centres,
servers, telecom applications, lab testing equipments and industrial
applications. The Master series (1P/1P) comes with a wide input voltage
range that protects devices against outages, disturbances and spikes. In
addition, this device comes with a smart battery charger that optimizes
the battery performance, ensuring longer lasting battery life. High voltage
battery chargers and battery extension assembly are made available for
longer runtime applications. The Master series (1P/1P) also comes in
various capacities ranging from 1kVA to 10kVA to suit your needs.
The 6kVA and 10kVA UPS system comes with 2 additional features; an
internal bypass system and a parallel redundant system. An internal
bypass system allowing continuous power is integrated for convenience
when maintenance is necessary and a parallel redundant system that
allows two UPS models to operate in parallel as backup for each other.
• True Double-Conversion Online UPS
• Output Power Factor 0.8
• Wide input voltage range (110~300V)
• Programmable power management outlets
• 50/60 Hz Frequency Converter Mode
• ECO mode operation for energy saving
• Emergency Power Off (EPO) Function
• SNMP/USB+RS-232 multiple communications
(SNMP is optional)
• DSP technology applied for 6K and up models
• Smart battery charger design to optimize battery
performance
• Maintenance bypass available for 6K and up models
• Optional hot standby mode and N+X parallel redundancy
available for 6K and up models
• Adjustable battery numbers for 6K and up models
• Built-in isolation transformer (Option)
Rear Panel
For 1kVA to 3kVA model
1. Programmable outlets: connect to non-critical loads
2. Output receptacles: connect to mission critical loads
3. AC input
4. Input circuit breaker
5. Network/ Fax/ Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery connection (only available for L model)
11. Output terminal
12. Output circuit breaker
13. Fan
7
7
8
6
13
4
9
7
6
9
5
8
3
PRO801S/L
PRO8015S/L
10
5
10
13
12
1
2
9
6
5
13
10
8
13
4
13
2
1
3
4
3
PRO802S/L
2
1
11
PRO803S/L
08
Online UPS
For 6kVA to 10kVA model
1
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Input circuit breaker
11. Input/Output terminal
12. Output terminal 1
13. Output terminal 2
14. External battery terminal (only available for Long-run model)
15. Utility input terminal
16. Output IEC Socket
2 3
4
5
5
6
8
7
14
8
9
10
16
12 13 15 11
PRO806S/L
PRO810S/L
Battery Pack
For 1kVA to 3kVA model
Model
Battery Type
Battery Number (max)
G6
G12
G18
12V7AH
12V9AH
12V7AH
12V9AH
12V7AH
12V9AH
6 pcs
6 pcs
12 pcs
12 pcs
18 pcs
18 pcs
Dimension (DxWxH) mm
397 × 145 × 220
421 × 190 × 318
535 × 190 × 318
Weight (kg)
18
36
55
20
40
61
For 6kVA to 10kVA model
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
G40
G60
12V7AH
12V9AH
40 pcs
40 pcs
592 × 250 × 576
109
125
12V7AH / 12V9AH
60 pcs
60 pcs
830 × 250 × 576
166
190
09
Online UPS
Options
• AS-400 Card (External alarm indicator)
• SNMP Card for data communication via network connection
• Output Isolation Transformer
• External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA)
Full Specifications
MODELS
PRO801S/ L
PRO8015S/ L
PRO802S/ L
Phase
PRO803S/ L
PRO806S/ L
PRO810S/ L
6000 VA
10000 VA
Single phase with ground
Capacity
1000 VA
INPUT
Nominal Voltage
1500 VA
2000 VA
3000 VA
200/208/220/230/240 VAC or 100/110/115/120/127 VAC
208/220/230/240 VAC
55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load
80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
110-300 VAC at 50% load
176-300 VAC at 100% load
Voltage Range
Frequency Range
40 ~ 70Hz
46 ~ 54 Hz or 56 ~ 64 Hz
≧ 0.99 @ Nominal Voltage (100% Load)
≧0.99 @ 100% Load
200/208/220/230/240 VAC or 100/110/115/120/127 VAC
208/220/230/240 VAC
Power Factor
OUTPUT
Output Voltage
Voltage Regulation (Batt. Mode)
±1%
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
47~53 Hz or 57~63 Hz
46 ~ 54 Hz or 56 ~ 64 Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
3:1
Current Crest Ratio
≦ 2 % THD (Linear Load)
≦ 4 % THD (Non-linear Load)
Harmonic Distortion
Transfer Time
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Zero
AC Mode to Batt. Mode
4 ms (Typical)
Inverter to Bypass
Zero
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
87%
90%
89%
Battery Mode
83%
87%
88%
BATTERY
Type
12 V / 7 Ah
Number
Standard Model
12 V / 9 Ah
12 V / 7 Ah
3
Recharge Time (Typical)
12 V / 7 Ah
12 V / 9 Ah
20
Back to 90%
Back to 90%
capacity in 7 hours capacity in 9 hours
Back to 90% capacity in 4 hours
Charging Current
1.0A (max)
Charging Voltage
41.0 VDC ± 1%
Battery Type
Long-Run Model
12 V / 9 Ah
6
Numbers
82.1 VDC ±1%
Depending on the application
273.0 VDC ±1%
6
18-20
82.1 VDC ±1%
273.0 VDC ±1%
3
8.0A
Charging Current
Charging Voltage
4.0A
41.0 VDC ± 1%
INDICATORS
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
LCD Display
ALARM
Battery Mode
Sounding every 4 seconds
Sounding every second
Low Battery
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
14
26
397×145×220
Dimension (mm) D × W × H
Net Weight (kgs)
421 × 190 × 318
397 x 145 x 220
13
7
592 x 250 x 576
28
81
421×190×318
7
13
83
592 x 250 x 576
13
25
27
Less than
55dB@1Meter
Less than
58dB@1Meter
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232
USB
Optional SNMP
20-90 % RH @ 0- 40°C (Non-condensing)
Less than 50dB@1Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%).
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
10
Online UPS
True double-conversion Online UPS
A true double conversion UPS will provide clean, high
level quality power to fully protect mission-critical
devices such as sensitive networks, small computer
centers, servers, telecom applications, as well as for
industrial applications.
Output Power factor of 0.8
As compared to the online UPS models in the current
market, the Master Series (1P/1P) provides better output
power factor of up to 0.8. This unit is able to offer higher
performance and efficiency for your critical applications.
Wide Input Voltage Range (110 V -300 V)
Master Series (1P/1P) can still provide stable power to
connected devices under unstable power environments.
Programmable Power Management Outlets
The
programmable
power
management outlets allow users to
easily and independently control the
load segment. In the event of a
power failure, this feature enables
users to manage and extend the
battery time for mission critical
devices by shutting down the
non-critical devices.
Programmable Outlets (P1)
- connect to non-critical devices
50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power
sensitive equipments.
ECO Mode Operation For Energy Saving
Offers efficiency as high as 97% to cut energy usage &
cost. UPS power application via static bypass, timely
returning to online double conversion when the need
arises.
Emergency Power Off (EPO) Function
This feature can protect the personnel and the
equipment in the case of fire outbreak or other types of
emergency.
SNMP + USB + RS-232 Multiple
Communication port for Models ranging from 1
to 3kVA.
This feature allows either the USB or RS-232
communication port to simultaneously operate with the
SNMP interface.
Higher Accuracy for Output Voltage
The advanced control firmware allows the Master Series
(1P/1P) to achieve higher accuracy with the output
voltage tolerance of +/- 1%. The device is applicable for
the use with critical test and IT equipments.
Smart Battery Charger Design to Optimise
Battery Performance
Master Series (1P/1P) 1-3kVA models are equipped with
a 2-stage charger design to guarantee precise battery
discharge time. The charging voltage is also
automatically adjusted according to the ambient
temperature, to lengthen the service life of the battery.
The 6kVA and 10kVA models come with an additional
extendable charger that allows for large-capacity battery
charging.
DSP Technology (Applies for the above
models)
A DSP controller improves the performance and
efficiency of the UPS.
Maintenance Bypass Available For 6kVA And
Above Models
Internal bypass assures continuous power to critical
devices during UPS maintenance.
Optional Hot Standby and N+X Parallel
Redundant System (Available for Models
ranging from 6kVA and above)
An internal bypass system allowing continuous power is
integrated for convenience when maintenance is
necessary and a parallel redundant system that allows
two UPS models to operate in parallel as backup for each
other.
11
Online UPS
Master Series (1P/1P) - Tower
Online Master E Series
6kVA – 10kVA
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
0.9
Output Power
Factor
Servers
Master E Series (1P/1P) is a single-phase UPS system that employs a true online
double-conversion technology. It is designed to deliver clean and high quality
electrical power for devices such as small computer centres, servers, telecom
applications, lab testing equipments and industrial applications. The Master E
Series (1P/1P) comes with a wide input voltage range that protects devices
against outages, disturbances and spikes. In addition, this device comes with a
smart battery charger that optimizes the battery performance, ensuring longer
lasting battery life. High voltage battery chargers and battery extension assembly
are made available for longer runtime applications. The E-Series provides better
output power factor of up to 0.9, offering high performance and efficiency for your
critical applications.
The Master E Series (1P/1P) comes with 2 additional features; an internal bypass
system and a parallel redundant system. An internal bypass system that allows
continuous power is integrated for convenience when maintenance is necessary
and a parallel redundant system that allows two UPS models to operate in
parallel as backup for each other.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.9
• Wide input voltage range (110-300 VAC)
• Active input power factor correction 0.99
• 50Hz/60Hz frequency converter mode
• Eco mode operation for energy saving (ECO)
• Programmable power management outlets
• Emergency power off function (EPO)
• Generator compatible
• Charger capacity expansion to 8A for long-run models
• SNMP/USB/RS-232 communications
• 3-stage extendable charging design for optimized battery
performance
• Adjustable battery numbers
• Maintenance bypass available
Rear Panel
For 6kVA to 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Input circuit breaker
11. Input/Output terminal
12. Output terminal 1
13. Output terminal 2
14. External battery terminal (only available for Long-run model)
15. Utility input terminal
16. Output IEC Socket
1
2 3
4
5
5
6
8
8
7
14
9
10
16
12 13 15 11
PRO806ES/EL
PRO810ES/EL
12
Online UPS
Options
• AS-400 Card (External alarm indicator)
• SNMP Card for data communication via network connection
• Output Isolation Transformer
Full Specifications
MODELS
Phase
Capacity
PRO810ES/EL
PRO806ES/EL
Single phase with ground
6000 VA
10000 VA
INPUT
Nominal Voltage
208/220/230/240 VAC
110-300 VAC at 50% load
176-300 VAC at 100% load
Voltage Range
Frequency Range
46~54 Hz or 56~64 Hz
≧ 0.99 @ full load
Power Factor
OUTPUT
Output Voltage
200/ 208/ 220/ 230/ 240VAC
AC Voltage Regulation (Batt. Mode)
±1%
Frequency Range (Synchronized Range)
46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio
3:1 (max)
Harmonic Distortion
≦ 3 % THD (Linear Load), ≦ 6 % THD (Non-linear Load)
Transfer Time
Zero
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
89%
Battery Mode
88%
BATTERY
Type
Standard Model
12 V / 7 Ah
12 V / 9 Ah
Numbers
Recharge Time (Typical)
20
7 hours recover to 90% capacity
Charging Current
Charging Voltage
Depending on the application
Type
Numbers
Long-Run Model
9 hours recover to 90% capacity
1.0 A (max)
273 VDC ± 1%
18-20
Charging Current
4.0 A (max)
Charging Voltage
273 VDC ± 1%
INDICATORS
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
LCD Display
INDICATORS
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Sounding twice every second
Overload
Fault
Continously sounding
PHYSICAL
Standard Model
Long-Run Model
592 x 250 x 576
Dimension (mm) D x W × H
Net Weight (kgs)
81
83
Dimension (mm) D × W × H
Net Weight (kgs)
592 x 250 x 576
25
27
ENVIRONMENT
Operation Humidity
20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level
Less than 55dBA @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC
Optional SNMP
Less than 58dB @ 1 Meter
Power management from SNMP manager and web browser
A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%).
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
13
Online UPS
Master Series (1P/1P) - 2-in-1 Rack/ Tower
Online Master Series 1kVA – 10kVA
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Servers
19” Rack
Mount
0.9
Output Power
Factor
Master Series (1P/1P) – 2-in-1 Rack/Tower is a single-phase UPS system that employs a true online
double-conversion technology. This device comes with a practical 2U universal-mount case that provides an
option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount
bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance
and efficiency to meet the requirements of a mission critical environment.
This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate the
replacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models
with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate
in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made
available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of
capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need.
• True Double-Conversion Online UPS
• Output Power factor of 0.9
• User-friendly and easy-shift LCD display
• Rack/ Tower design
• Programmable power management outlets for 1-3K
• 50/60 Hz frequency converter mode
• ECO and advanced ECO mode for energy saving
• Emergency Power Off Function (EPO)
• Hot-swappable battery design for all model
• DSP technology applied for 6K and up models
• Active input power factor correction 0.99 for 6K and up models
• N+X parallel redundancy available for 6K and up models
14
Online UPS
Rear Panel
For 1kVA to 3kVA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery terminal (only available for Long-run model)
11. Output IEC320-C20 connector
12. Fan
1
7
5
12
6 10
3
9
8
2
4
PRO801RS/RL PRO8015RS/RL PRO802RS/RL
1
7
5
12
10
12
8
3
11
9 6
2
4
PRO803RS/RL
For 6kVA to 10kVA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery connection
11. Input terminal
12. Fan
13. Parallel port (only available for parallel model)
14. External maintenance by-pass switch connection
15. Output Terminal
16. Ground
13
9
6
7
14
7
4
12
10
11 16 15
PRO806RS/RL
PRO810RS/RL
Battery Pack
For 1kVA to 3kVA model
Capacity
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Net Weight (kg)
1K
1.5K
2K
3K
12 V / 9 Ah
12 V / 9 Ah
12 V / 9 Ah
12 V / 9 Ah
4 pcs
6 pcs
8 pcs
12 pcs
380 x 438 x 88
480 x 438 x 88
17.3
24.8
600 x 438 x 88
29.8
42.5
For 6kVA to 10kVA model
Capacity
Battery Type
Battery Number (max)
6K
10K
12 V / 7 Ah
12 V / 9 Ah
20 pcs
20 pcs
Dimension (DxWxH) mm
Net Weight (kg)
580 x 438 x 133
57
63
15
Online UPS
Options
• AS-400 Card (External alarm indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (communication interface)
• Universal Rackmount Slider for installation in rack cabinets
• External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA)
• Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA)
• External Automatic Transfer Switch (ATS)
Full Specifications
MODELS
Phase
PRO801RS/ RL
Capacity
1000 VA
PRO8015RS/ RL
PRO802RS/ RL
Single phase with ground
1500 VA
INPUT
Nominal Voltage
PRO803RS/ RL
2000 VA
3000 VA
100*/110*/115*/120 /127 VAC or 200/208/220/230/240 VAC
Voltage Range
55-150 VAC ± 5% or 110-300 VAC ± 5%
Frequency Range
40Hz ~ 70Hz
≧ 0.99 @ Nominal Voltage (100% Load)
Power Factor
OUTPUT
Output Voltage
100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
±1%
Voltage Regulation (Batt. Mode)
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Synchronized Range)
50 Hz ± 0.5% or 60Hz ± 0.5%
Frequency Range (Batt. Mode)
5:1 (max.)
Current Crest Ratio
≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear load)
Harmonic Distortion (Line Mode)
Transfer Time
Zero
Line Mode to Battery Mode
4 ms
Inverter to Bypass
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
87%
88%
89%
Battery Mode
85%
86%
87%
ECO Mode
94%
95%
97%
BATTERY
Battery Type
Standard Model
Number
12 V / 9 Ah
3
2
Recharge Time (Typical)
Charging Current (Max.)
Charging Voltage
Battery Type
Long-Run Model
1.0A
41.1 VDC ± 1%
27.4 VDC ± 1%
54.7 VDC ±1%
82.1 VDC ±1%
Depending on the capacity
of external batteries
Number
Recharge Time (Typical)
Charging Current (Max.)
Charging Voltage
6
4
Back to 90% capacity in 4 hours
1A / 2A / 4A / 8A
41.1 VDC ± 1%
27.4 VDC ± 1%
54.7 VDC ±1%
82.1 VDC ±1%
INDICATORS
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator
LCD Display
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Continously sounding
Fault
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
380x438x88 (2U)
Net Weight (kgs)
Dimension (mm) D × W × H
12.9
380x438x88 (2U)
17.6
8.6
10.7
Net Weight (kgs)
480x438x88 (2U)
600x438x88 (2U)
20.6
28
600x43x88(2U)
11.3
13.8
480x438x88 (2U)
ENVIRONMENT
Operation Humidity
20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Less than 50dBA @ 1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
*All specifications, designs and contents are subject to change without prior notice.
16
Online UPS
Full Specifications
MODELS
Phase
PRO806RS/ RL
Capacity
6000 VA
PRO810RS/ RL
Single phase with ground
10000 VA
INPUT
Nominal Voltage
200/208/220/230/240 VAC
Voltage Range
110-300 VAC ± 3% at 50% load; 176-300 VAC ± 3% at 100% load
Frequency Range
46~54 Hz or 56~64 Hz
≧ 0.99 @ 100% load
Power Factor
OUTPUT
200/208/220/230/240 VAC
Nominal Voltage
AC Voltage Regulation
200/208/220/230/240 VAC
±1%
±1%
46~54 Hz or 56~64 Hz
Frequency Range (Synchronized Range)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Frequency Range (Batt. Mode)
3:1 (Max.)
Current Crest Ratio
≦ 2 % THD (Linear Load),
≦ 4 % THD (Non-linear Load)
Harmonic Distortion
≦ 2 % THD (Linear Load),
≦ 4 % THD (Non-linear Load)
0 ms
Line Mode to Battery Mode
Transfer Time
Battery Mode to Line mode
4 ms
Inverter to Bypass
Bypass to Inverter
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
Line Mode
90%
90%
Battery Mode
88%
88%
ECO Mode
96%
96%
BATTERY
Nominal Voltage
Standard Model
Battery Type
Numbers
Recharge Time (Typical)
240 VDC
12 V / 7 Ah
12 V / 9 Ah
20 (18-20 pcs adjustable)*
20 (18-20 pcs adjustable)*
Back to 90% capacity in 7 hours
Back to 90% capacity in 9 hours
1.0 A
273 VDC (based on battery numbers at 20 pcs)
Charging Current (max.)
Float Charging Voltage
Depending on the application
Battery Type and Numbers
Long-Run Model
Charging Current (max.)
4.0 A
Float Charging Voltage
273 VDC (based on battery numbers at 20 pcs)
INDICATORS
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator
LCD Display
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continously sounding
PHYSICAL
UPS Unit: 580 x 438 x 133 (3U)
Battery Pack: 580 x 438 x133 (3U)
UPS Unit: 668 x 438 x 133 (3U)
Battery Pack: 580 x 438 x133 (3U)
Net Weight (kgs)
UPS Unit: 20
Battery Pack: 57
UPS Unit: 23.5
Battery Pack: 63
Dimension (mm) D x W × H
580 x 438 x 133
668 x 438 x 133
20
23.5
Dimension (mm) D x W × H
Standard Model
Long-Run Model
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 58dBA @ 1 Meter
Less than 60dBA @ 1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
*All specifications, designs and contents are subject to change without prior notice.
17
Online UPS
True Double-conversion Online UPS
Output Power Factor 0.9
A true double conversion UPS system will provide clean
and high quality electrical power to fully protect mission
critical systems such as sensitive networks, small
computer centers, servers, telecom applications and
industrial applications.
Master (1P/1P) 2-in-1 rack/Tower Series is a
high-density UPS system with an output power factor of
0.9. With this high power factor, the Master series is able
to provide higher performance to critical applications.
Programmable Power Management Outlets
User-friendly LCD Display
The front panel digital display comes with an
auto-rotation feature that caters to your installation
preference; either vertically or wall mounted.
The programmable power management outlets allow
users to easily and independently control the load
segment. In the event of a power failure, this feature
enables users to manage and extend the battery time for
mission critical devices by shutting down the non-critical
devices.
Programmable Outlets (P1)
- connect to non-critical
devices
Rack Display
Tower Display
ECO and Advanced ECO Mode for Energy Saving
Rack / Tower Design
This device comes with a practical 2U universal-mount
case that provides an option for the user to either install
it as a floor-standing tower or in a mounting position
using a 19-inch rack mount bracket.
It allows the UPS to operate in high efficiency of up to
97% during energy saving ECO mode and 98% in
operation mode. In the event of an electrical AC failure,
the inverter will automatically step-in and provide
electrical supply to the connected systems.
Emergency Power Off Function (EPO)
This feature provides adequate protection for the user
and the equipment against hazards such as fire
break-out or other emergencies.
19” Rack-mounting
Floor-standing Tower
High Output Crest Ratio
The Master (1P/1P) 2-in-1 Rack/Tower Series is
designed with a high output crest ratio of 5:1 that allows
the device to be extremely compatible with equipment
such as compressors, generators and motors.
Hot-swapping Battery Design
The hot-swapping battery feature helps to facilitate the
replacement of the existing batteries without the hassle
of having to shut the devices down.
Output Voltage Regulation (tolerance +/- 1%)
The Master (1P/1P) 2-in-1 rack / Tower Series is able to
produce extremely stable and clean electrical power with
its high efficiency output voltage regulator. This regulator
is able to achieve a tolerance of +/- 1%, making it
extremely compatible even with sensitive power
supplies.
Long Battery Runtime Models Available
Our Long Battery Runtime Models offers the flexibility to
add-on additional external batteries to provide a longer
back-up time.
18
Online UPS
Master Series (3P/1P) - Tower
Online Master Series
10kVA – 30kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Master Series (3P/1P) three-phase input / single-phase output, true online double conversion
UPS system guarantees consistent and quality electrical power to protect your mission
critical applications such as mid-sized business servers, telecommunication systems and
industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle
voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to
30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage
switching characteristics during generator operation. An internal bypass system allowing
continuous power is also integrated for convenience when maintenance is necessary. In
addition, this device comes with a parallel redundant system that allows two UPS models to
operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers
the option of adding on an isolation transformer to suit your requirements.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.8
• Wide Input Voltage Range (305-478VAC for 3-Phase/
100-300VAC for 1-Phase)
• Supports Auto Phase Adaptation
• Active power factor correction in all phases
• Built-in phase auto adapt function simplifies wire installation
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
Rear Panel
• Programmable power management outlets
• Emergency power off function (EPO)
• Generator compatible
• SNMP/USB+RS-232 multiple communications
(SNMP is optional)
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer available
For 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. External battery connector (Only available for Long-run Model)
1 2 3
4
8
5
6
5
7
14
8
9
10
11
12
13
PRO83110S/L
19
Online UPS
For 15kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. Output Terminal: Connect to mission-critical loads
15. Programmable Output terminal: Connect to non-critical loads
16. External battery terminal (only available for Long-run model)
17. Utility input terminal
18. Grounding terminal (only available for parallel system)
For 10K model
1 2 3
4 5
8
4
8
5
6
7
5
9
7
5
7
8
1 2 3
6
10
11
8
7
9
10
11
18
PRO83115L
PRO83120L
PRO83115S
PRO83120S
PRO83130S/L
PRO83130L
For 15K & 30K model
18
14 15
17
14 15 16
17
Options
• AS-400 Card (External alarm indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer (Available only for Long-run Model)
20
Online UPS
Full Specifications
MODELS
PRO83110S/ L
PRO83115S/ L
Phase
PRO83120S/ L
PRO83130S/ L
3-phase in / 1-phase out
Capacity
10 kVA
15 kVA
20 kVA
30kVA
INPUT
Nominal Voltage
3 x 400VAC (3Ph+N)
Voltage Range
305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load
Frequency Range
46~54Hz or 56~64Hz
Power Factor
≧ 0.99 @ 100% Load
< 6% @ 100% load
THDi
OUTPUT
Output Voltage
208/220/230/240VAC
Voltage Regulation (Batt. Mode)
±1%
46~54Hz or 56~64Hz
Frequency Range (Synchronized Range)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Frequency Range (Batt. Mode)
3:1
Current Crest Ratio
≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Harmonic Distortion
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Zero
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
89%
Battery Mode
86%
90%
88%
87%
89%
BATTERY
Battery Type
Numbers
Standard Model
12 V / 9 Ah
20 pcs
(18 - 20 pcs adjustable)*
20 pcs (18 - 20 pcs adjustable)* x 2 strings
Recharge Time (Typical)
Charging Current (Max.)
Back to 90% capacity in 9 hours
1A
2A
Charging Voltage
Depending on the application
Depending on the application
Numbers
Charging Current (Max.)
2A
273 VDC ± 1% (Based on 20pcs batteries)
Battery Type
Long-Run Model
20pcs(18-20pcs
adjustable)*x3 strings
4A
8A
Charging Voltage
12 A
273 VDC ± 1% (Based on 20pcs batteries)
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continously sounding
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
Dimension (mm) D × W × H
Net Weight (kgs)
592 x 250 x 576
815 × 250 × 826
83
164
234
592 ×250 × 576
592 x 250 x 576
815 × 250 × 826
28
40
64
815 × 300 × 1000
ENVIRONMENT
Humidity
Noise Level
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 58dB @ 1 Meter
Less than 60dB @1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
21
Online UPS
0.9
Master Series (3P/1P) - Tower
Output Power
Factor
Online Master E Series
10kVA – 30kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Master E Series (3P/1P) three-phase input / single-phase output, true online double conversion
UPS system guarantees consistent and quality electrical power to protect your mission critical
applications such as mid-sized business servers, telecommunication systems and industrial
equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage
fluctuating situations and a high accuracy output voltage to fail-safe your equipment. The
E-Series provides better output power factor of up to 0.9; offering high performance and efficiency
for your critical applications.
By adopting the latest IGBT technology, this device is able offer excellent voltage switching
characteristics during generator operation. In addition, this device comes with a parallel
redundant system that allows two UPS models to operate in parallel and as backup for each other.
The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit
your requirements.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.9
• Wide input voltage range (110-300 VAC)
• Active power factor correction in all phases
• Built-in phase auto adapt function simplifies wire installation
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
• Programmable power management outlets
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer available
Rear Panel
For 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. External battery connector (Only available for Long-run Model)
1 2 3
4
8
5
6
5
7
14
8
9
10
11
12
13
PRO83110ES/EL
PRO83110ELI
22
Online UPS
For 15kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. Output Terminal: Connect to mission-critical loads
15. Programmable Output terminal: Connect to non-critical loads
16. External battery terminal (only available for Long-run model)
17. Utility input terminal
18. Grounding terminal (only available for parallel system)
For 10K model
1 2 3
4 5
8
4
8
5
6
7
5
9
7
5
7
8
1 2 3
6
10
11
8
7
9
10
11
18
PRO83115ES/ EL
PRO83120ES/ EL
PRO83120ELI
PRO83130ES/ EL
For 15K & 30K model
18
14 15
17
14 15 16
17
Options
• AS-400 Card (External alarm indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer (Available only for PRO83110ELI & PRO83120ELI)
23
Online UPS
Full Specifications
MODELS
PRO83110ES/ EL
PRO83110ELI
PRO83115ES/ EL PRO83120ES/ EL
Phase
PRO83120ELI
PRO83130ES/ EL
20kVA
30kVA
3-phase in / 1-phase out
Capacity
10kVA
10kVA
20kVA
15kVA
INPUT
Nominal Voltage
3 x 400VAC (3Ph+N)
Voltage Range
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
46 ~ 54Hz or 56 ~ 64Hz
≧ 0.99 @ 100% load
Power Factor
< 6% @ 100% load
THDi
OUTPUT
208/220/230/
240VAC
Output Voltage
104/110/115/
120VAC or 208/
220/230/240VAC
Voltage Regulation (Batt. Mode)
208/220/230/240VAC
208/220/230/
240VAC
±1%
46~54Hz or 56~64Hz
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
3.1
Current Crest Ratio
≦2 % THD
≦2 % THD
(Linear Load)
(Linear Load)
≦5 % THD
≦6% THD
(Non-linear Load) (Non-linear Load)
Harmonic Distortion
Transfer Time
104/110/115/
120VAC or 208/
220/230/240VAC
≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
≦2 % THD
≦2 % THD
(Linear Load)
(Linear Load)
≦7% THD
≦5% THD
(Non-linear Load) (Non-linear Load)
Zero
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
91%
85%
Battery Mode
86%
83%
91%
88%
87%
87%
91%
83%
88%
BATTERY
Battery Type
Numbers
Standard Model
12 V / 9 Ah
20 pcs (18 - 20 pcs adjustable)*
Recharge Time (Typical)
20 pcs (18 - 20 pcs adjustable)* x 2 strings
Back to 90% capacity in 9 hours
Charging Current (Max.)
Charging Voltage
1A
Back to 90%
capacity in 9 hours
2A
273 VDC ± 1% (Based on 20pcs batteries)
Battery Type
2A
Depending on the application
Numbers
Long-Run Model
Not Applicable
20pcs(18-20pcs
adjustable)
x3 strings
Depending on the application
4A
Charging Current (Max.)
8A
Charging Voltage
12A
273 VDC ± 1% (Based on 20pcs batteries)
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding twice every second
Overload
Sounding twice every second
Continously sounding
Fault
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
Dimension (mm) D × W × H
Net Weight (kgs)
592 x 250 x 576
592 x 250 x 826
815 × 250 × 826
83
144
164
592 ×250 × 576
592 x 250 x 826
592 x 250 x 576
28
91
40
Not Applicable
815 × 300 × 1000
234
815 × 250 × 826
141
64
ENVIRONMENT
Humidity
Noise Level
0 - 95% RH @ 0 - 40°C (Non-condensing)
Less than 58dB @ 1 Meter
Less than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
24
Online UPS
Master Series (3P/1P) - Rack Mount
Online Master Series 10kVA – 20kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
19” Rack
Mount
Storage
PLCS
Emergency
Alarm
Devices
Master Series (3P/1P) – Rack three-phase input / single-phase output, true online double conversion UPS system
guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized
business servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide
input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your
equipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest
IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An
internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary.
In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as
backup for each other. The Master series (3P/1P) – Rack UPS also offers the option of adding on an isolation transformer
to suit your requirements.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.8
• Wide input voltage range (110-300 VAC)
• Active power factor correction in all phases
• Built-in phase auto adapt function simplifies wire
installation
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
• Emergency power off function (EPO)
• Generator compatible
• SNMP/USB+RS-232 multiple communications (SNMP is
optional)
• 3-stage extendable charging design for optimized battery
performance
• Adjustable battery numbers
• Optional N+X parallel redundancy
Rear Panel
For 10kVA to 20kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Parallel port (only available for parallel model)
5. Intelligent slot
6. Fan
7. External maintenance by-pass switch connection
8. Input circuit breaker
9. Input/Output terminal
10. Output terminal
11. Battery terminal
12. Input terminal
4
4
5
11
4
7
8
1
6
6
2
3
9 12 10
PRO83110RS/RL
5
7
1
6
9
6
12
10
2
3
4
8
6
6
4
4
11
PRO83115RS/ RL PRO83120RS/RL
25
Online UPS
Options
• AS-400 Card (External Alarm Indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Universal Rackmount Slider for installation in rack cabinets
• External Maintenance Bypass Switch (Only available with 10kVA model)
Full Specifications
MODELS
PRO83110RS/ RL
PRO83115RS/ RL
Phase
PRO83120RS/ RL
3-phase in / 1-phase out
10kVA
Capacity
20kVA
15kVA
INPUT
Nominal Voltage
3 x 400 VAC (3Ph+N)
Voltage Range
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
46~54 Hz or 56~64Hz
≧ 0.99 @ 100% Load
Power Factor
< 6% @ 100% Load
THDi
OUTPUT
Output Voltage
208/220/230/240VAC
AC Voltage Regulation (Batt. Mode)
±1%
46~54Hz or 56~64Hz
Frequency Range (Synchronized Range)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Frequency Range (Batt. Mode)
Current Crest Ratio
3:1
Harmonic Distortion
≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer Time
Zero
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
89%
AC Mode
Battery Mode
86%
88%
87%
BATTERY
Battery Type
Standard Model
Numbers
12 V / 9 Ah
20 (18 - 20 adjustable)
20 pcs x 2 strings (18 - 20 adjustable)
Recharge Time (Typical)
Charging Current (Max.)
Back to 90% capacity in 9 hours
1A
2A
273 VDC ± 1% (based on battery numbers at 20 pcs)
Charging Voltage
Battery Type
Long-Run Model
Depending on the capacity of external batteries
Numbers
Charging Current (Max.)
4A
Charging Voltage
273 VDC ± 1% (based on battery numbers at 20 pcs)
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Sounding every second
Low Battery
Sounding twice every second
Overload
Fault
Continously sounding
PHYSICAL
Standard Model
Dimension (mm) D x W × H
Net Weight (kgs)
Long-Run Model
Dimension (mm) D × W × H
Net Weight (kgs)
UPS Unit: 668 x 438 x 133 (3U)
Battery Pack: 580 x 438 x 133 (3U)
UPS Unit: 668 x 438 x 266 (6U)
BatteryPack: 580 x 438 x 133 (3U) x 2PCS
UPS unit: 22
Battery pack: 63
UPS unit: 45
Battery pack: 63 x 2PCS
668 x 438 x 133 (3U)
668 x 438 x 266 (6U)
22
45
ENVIRONMENT
Operation Humidity
Noise Level
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 60dB @ 1 Meter
Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
*All specifications, designs and contents are subject to change without prior notice.
26
Online UPS
Master Series (3P/3P) - Tower
Online Master Series
10kVA – 30kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Master Series (3P/3P) – Tower three-phase input / three-phase output, true online
double conversion UPS system guarantees consistent and quality electrical power to
protect your mission critical applications such as small server room, medical devices,
telecommunication facilities and industrial processes. This (3P/3P) UPS is designed
with a wide input voltage range to handle voltage fluctuating situations and a high
accuracy output voltage to fail-safe your equipment.
The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA.
By adopting the latest IGBT technology, this device is able offer excellent
voltage-switching characteristics during generator operation. An internal bypass
system allowing continuous power is also integrated for convenience when
maintenance is necessary. In addition, this device comes with a parallel redundant
system that allows two UPS models to operate in parallel and as backup for each
other. The Tower series UPS also offers the option of adding on an isolation
transformer to suit your requirements.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.8
• Active power factor correction in all phases
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
• Accepts dual-mains inputs (only available for dual input
unit)
• Emergency power off function (EPO)
• Generator compatible
• SNMP/USB+RS-232 multiple communications (SNMP
is optional)
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer offers full isolation and
complete common mode noise rejection
Rear Panel
1 2 3 4
6
8
For 10kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Bypass Input Circuit Breaker (Only available for dual input unit)
11. Input circuit breaker
12. Input/Output terminal
13. External battery terminal (only available for Long-run model)
5
7
8
9
7
11 10 13
12
PRO83310S/L
PRO83320S/L
PRO83330S/L
27
Online UPS
Options
• AS-400 Card (External Alarm Indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer
Full Specifications
MODELS
PRO83310S/ L
PRO83315S/ L
Phase
PRO83320S/ L
10kVA
Capacity
15kVA
INPUT
Nominal Voltage
30kVA
20kVA
3 x 400 VAC (3Ph+N)
Input Voltage Range
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
46~54 Hz or 56~64Hz
Power Factor
≧ 0.99 @ 100% Load
OUTPUT
Output Voltage
3 x 400 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronized Range)
46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio
3:1 (Max.)
Harmonic Distortion
≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer Time
PRO83330S/ L
3-phase in / 3-phase out
Zero
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
89%
88%
86%
90%
89%
87%
BATTERY
Battery Type
Numbers
Standard Model
12 V / 9 Ah
20 pcs
(18 - 20 adjustable)*
20 pcs x 2 strings (18 - 20 adjustable)*
Recharge Time (Typical)
Charging Current (Max.)
Back to 90% capacity in 9 hours
2A
1A
4A
273 VDC ± 1%
Charging Voltage
Battery Type
Long-Run Model
20pcs x 3 strings
(18-20 adjustable)*
Depending on the capacity of external batteries
Numbers
4A
Charging Current (Max.)
12A
273 VDC ± 1%
Charging Voltage
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault
ALARM
Battery Mode
Sounding every 4 seconds
Sounding every second
Low Battery
Overload
Sounding twice every second
Fault
Continously sounding
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
815 x 250 x 826
109
Dimension (mm) D × W × H
Net Weight (kgs)
815 x 300 x 1000
164
592 x 250 x 826
38
233.5
815 x 250 x 826
40
64
ENVIRONMENT
Humidity
Noise Level
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 60dB @ 1 Meter
Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
28
Online UPS
0.9
Master Series (3P/3P) - Tower
Output Power
Factor
Online Master E Series
10kVA – 30kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Master E Series (3P/3P) – Tower three-phase input / three-phase output, true online
double conversion UPS system guarantees consistent and quality electrical power to
protect your mission critical applications such as small server room, medical devices,
telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with
a wide input voltage range to handle voltage fluctuating situations and a high accuracy
output voltage to fail-safe your equipment.
The Master E Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA.
By adopting the latest IGBT technology, this device is able offer excellent
voltage-switching characteristics during generator operation. An internal bypass system
allowing continuous power is also integrated for convenience when maintenance is
necessary. In addition, this device comes with a parallel redundant system that allows
two UPS models to operate in parallel and as backup for each other. The Tower series
UPS also offers the option of adding on an isolation transformer to suit your
requirements.
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.9
• Active power factor correction in all phases
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving (ECO)
• Accepts dual-mains inputs
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
Rear Panel
1 2 3 4
6
For 10kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Bypass Input Circuit Breaker (Only available for dual input unit)
11. Input circuit breaker
12. Input/Output terminal
13. External battery terminal (only available for Long-run model)
5
8
7
8
9
7
11 10 13
12
PRO83310ES/EL
PRO83320ES/EL
PRO83330ES/EL
29
Online UPS
Options
• AS-400 Card (External Alarm Indicator)
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer
Full Specifications
MODELS
PRO83310ES/ EL
PRO83315ES/ EL
Phase
PRO83320ES/ EL
10kVA
Capacity
15kVA
INPUT
Nominal Voltage
30kVA
20kVA
3 x 400 VAC (3Ph+N)
Input Voltage Range
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
46~54 Hz or 56~64Hz
Power Factor
≧ 0.99 @ 100% Load
OUTPUT
Output Voltage
3 x 400 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronized Range)
46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio
3:1 (Max.)
Harmonic Distortion
≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer Time
PRO83330ES/ EL
3-phase in / 3-phase out
Zero
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
89%
88%
86%
90%
89%
87%
BATTERY
Battery Type
Numbers
Standard Model
12 V / 9 Ah
20 pcs
(18 - 20 adjustable)*
20 pcs x 2 strings (18 - 20 adjustable)*
Recharge Time (Typical)
Charging Current (Max.)
Back to 90% capacity in 9 hours
2A
1A
Charging Voltage
4A
273 VDC ± 1%
Battery Type
Long-Run Model
20pcs x 3 strings
(18-20 adjustable)*
Depending on the capacity of external batteries
Numbers
Charging Current (Max.)
4A
Charging Voltage
12A
273 VDC ± 1%
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Continously sounding
Fault
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
815 x 250 x 826
109
Dimension (mm) D × W × H
Net Weight (kgs)
815 x 300 x 1000
164
592 x 250 x 826
38
233.5
815 x 250 x 826
40
64
ENVIRONMENT
Humidity
Noise Level
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 60dB @ 1 Meter
Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
30
Online UPS
Power Series
Online Power Series
15kVA – 120kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Power Series (3P/3P) three-phase input / three-phase output, true online double
conversion UPS system guarantees to supply consistent and quality electrical
power to protect your mission critical applications such as data centres, medical
equipments and call centres. Harmful effects of harmonic injection are
eliminated with the employment of Adaptive Feed Forward Cancellation (AFC)
technology. With a UPS system that reflects low harmonic distortion and high
input power factor, it is able to lower installation costs by utilizing smaller cables
and miniature circuit breakers (MCB).
Our team of specialists has gathered together to revolutionize the UPS usability
by adding in a 5.7” LCD monitor display with all information and alarm
notifications viewable within a single display. To ensure our products are user
centered, our group of specialist has also adopted a front access concept to
create a UPS system that is easy for users to carry out preventative
maintenance and replacement activities. In addition, this device comes with a
parallel redundant system that allows four UPS models to operate in parallel. An
option of an additional isolation transformer is also available to suit your
requirements. The Power series is available in models ranging from 15kVA to
120kVA.
• Online double conversion technology with DSP control
• Advanced control with Adaptive Feed Forward Cancellation
(AFC) technology for very low harmonic distortion
• Very low input current distortion (THDi < 1%)
• Input power factor 0.99 at 10% load
• Output efficiency up to 95%
• Space-saving compact design
• Front access makes maintenance and replacement easily
• Highly flexibility in single phase/three-phase set-ups
• Control designed to withstand all kinds of loads
• Parallel redundant operation with up to 4 units
• Variety of communication options available
• Over 60% mateirals recyclable
• Remaining backup time calculation
• 5.7" graphic LCD panel design with multiple
languates for easy-configuration
• Optional touch panel design for 5.7" LCD
1
Rear Panel (Internal)
For 15kVA to 80kVA model
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
3
1
3
2
10
10
2
3
10
1
2
4
4
4
5
6 7
8
5 6
5 6 7
7
8
8
9
9
9
PRO73315S/SI
PRO73320S/SI
PRO73330S/SI
PRO73340S/SI
PRO73360S/SI
PRO73380S/SI
31
Online UPS
1
For 100kVA to 120kVA model
2
3
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
10
4
5
6
7
8
9
PRO733100S
PRO733120S
Full Specifications
MODELS
PRO73315S/ SI
PRO73320S/ SI
PRO73330S/ SI
PRO73340S/ SI
PRO73360S/ SI
PRO73380S/ SI
Capacity
15kVA
20kVA
30kVA
40kVA
60kVA
80kVA
INPUT
Nominal Voltage
3 x 400V (3Ph + N)
Acceptable Voltage Range
+15% or –20%
Frequency
50/60 Hz ± 5 %
Total Harmonic Distortion (THDi)
< 1.5% @ 100% load
< 2.5% @ 50% load
< 6.0% @ 10% load
< 1.0% @ 100% load
< 2.0% @ 50% load
< 5.0% @ 10% load
High overload: PFC Limit (discharging batteries)
Current Limitation
1.0
Power Factor
INVERTER
Nominal Voltage
3 x 400V (3Ph + N)
Precision
Frequency
Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
50/60 Hz synchronised ±4 % With mains absent ±0.05%
±10 Hz/s
Max. Synchronisation Speed
Pure Sinewave
Waveform
<0.5% (Linear Load) ; <1.5% (Non-linear Load)
Total Harmonic Distortion (THDv)
Phase Displacement
120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)
10 ms. at 98 % of the static value
Dynamic Recovery Time
125% for 10 min., 150% for 60 s
Admissible Overload
3.4 : 1
Admissible Crest Factor
3.2 :1
2.8 : 1
0.7 inductive to 0.7 capacitive
Admissible Power Factor
<1%
Imbalance Output Voltage @ 100% Unbalanced Load
High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit
Current Limit
STATIC BYPASS
Solid state
Type
3x400V (3Ph + N)
Voltage
Frequency
50/60 Hz
Microprocessor control
Activation Criterion
Zero
Transfer Time
400% for 10 sec.
Admissible Overload
Immediate, for overloads above 150%
Transfer to Bypass
Automatic after alarm clear
Retransfer
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 x 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency (Line mode)
90.5%
91%
92%
92.5%
12V 4.5Ah
12V 9Ah
12V 12Ah
12V 18Ah
10
9
8
7
93%
94%
BATTERY
Built-in Battery Type (2x31)
Back-up Time (minutes)
Max. Charging Current
23.5 A
Not Applicable
47 A
70.5 A
PHYSICAL
Dimensions, D x W x H(mm)
700 x 450 x 1100
Net Weight (W/O batteries) (Kg)
Net Weight (w/built-in batteries) (Kg)
805 x 590 x 1320
110
280
180
300
430
210
565
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
230
Not Applicable
32
Online UPS
MODELS
PRO733100S
PRO733120S
Capacity
100kVA
120kVA
INPUT
Nominal Voltage
3 x 400V (3Ph + N)
Acceptable Voltage Range
+15% or –20%
Frequency
50/60 Hz ± 5 %
< 1.0% @ 100% load
< 2.0% @ 50% load
< 5.0% @ 10% load
Total Harmonic Distortion (THDi)
High overload: PFC Limit (discharging batteries)
Current Limitation
1.0
Power Factor
INVERTER
Nominal Voltage
3 x 400V (3Ph + N)
Precision
Frequency
Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
50/60 Hz synchronised ±4 % With mains absent ±0.05%
±10 Hz/s
Max. Synchronisation Speed
Pure Sinewave
Waveform
<0.5% (Linear Load) ; <1.5% (Non-linear Load)
Total Harmonic Distortion (THDv)
120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)
Phase Displacement
10 ms. at 98 % of the static value
Dynamic Recovery Time
125% for 10 min., 150% for 60 s
Admissible Overload
Admissible Crest Factor
3.2 :1
Admissible Power Factor
0.7 inductive to 0.7 capacitive
<1%
Imbalance Output Voltage @ 100% Unbalanced Load
High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit
Current Limit
STATIC BYPASS
Solid state
Type
3x400V (3Ph + N)
Voltage
Frequency
50/60 Hz
Microprocessor control
Activation Criterion
Zero
Transfer Time
400% for 10 sec.
Admissible Overload
Immediate, for overloads above 150%
Transfer to Bypass
Automatic after alarm clear
Retransfer
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 x 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency (Line mode)
93%
93.3%
BATTERY
Max. Charging Current
188 A
PHYSICAL
Dimensions, D x W x H(mm)
Net Weight (W/O batteries) (Kg)
Net Weight (w/built-in batteries) (Kg)
805 x 590 x 1320
255
Not Applicable
Options
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
33
Online UPS
The Power Series is designed with the new state of art
transformerless PWM technology that can be easily
adapted to any kinds of complicated loads such as the
non-linear systems (IT systems), highly inductive/
capacitive loads, high-density discharge lamps and
induction motors. The Power series is designed with 2
important criterions in mind; maximum efficiency and
energy conservation. The unit also comes with a small
form factor to allow for minimum installation effort.
Furthermore, a parallel redundant system is integrated to
allow two UPS models to operate in parallel as backup
for each other. The Power Series is available in
capacities ranging from 15 to 120kVA.
Online Double Conversion Technology with
DSP Control
The Power Series is able provide a higher load up-time
and effective insulation against network disturbance
with its online double conversion technology. A Digital
Signal Processor (DSP) controller improves the
performance and efficiency of the UPS.
Input Power Factor 0.99 At 10% Load
Lower power losses would result in reduced
consumption, lower operation and maintenance costs.
INPUT POWER FACTOR
1,20
1,00
0,80
PFin
The Most Versatile Solution For Power
Protection
0,60
0,40
0,20
0,00
0%
25%
50%
LOAD
Output Efficiency of up to 95%
Designed with a DSP controller and fourth generation
IGBT transistors, the UPS is able to achieve extremely
high efficiency of up to 95%. With such high ratings,
components in the UPS are not only protected but also
prolonged due to the decrease in heat losses.
SERIES TIPICAL EFFICIENCY
100%
Advanced Control with Adaptive Feed Forward
Cancellation (AFC) Technology
By cancelling both the input current and the output
voltage harmonics, the harmful effects of harmonic
injection can be eliminated and this enhances the load
integrity.
Low Input Current Distortion (THDi < 1%)
AFC cells are used to achieve extremely low distortion
values. The Power series is able to obtain a low input
current distortion at THDi < 1% under full load and a THDi
< 5% under smaller load (i.e. 10% of load). This will
prevent distortion of electrical network upstream and
thus, result in the reduction of cable usage and protective
devices in the electrical network.
EFFICIENCY
75%
50%
25%
0%
0%
25%
50%
LOAD
Small Form Factor
Utilizes a transformerless technology allows the design
of the UPS to be lighter and smaller.
34
Online UPS
An important consideration has
been given during the UPS design
phase to create a system that
allows users to access the
unit’s electronic cards and power
components
with
minimum
effort. All electronic boards and
components can be accessed
from the front panel for easy
maintenance and replacement
activities.
Variety Of
Available
Communications
And
Option
The UPS has provided the following standard
communication selections:
• Relay interface
• RS-232/485 port
• 1 × SNMP slot
• Modbus RTU / SEC protocol
• 2 × connectors for parallel connection
Made of 60% Recyclable
Materials
Versatile Single-Phase / Three-Phase set-ups
This highly versatile UPS is designed with different types
of setting-up options;
• Three-phase input / Three-phase output (III/III)
• Three-phase input / Single phase output (III/I)
When it comes to conserving the
environment, PROLiNK is committed to
play a part by designing their UPS
products using recyclable materials.
Back-up Time indicator
Control Components are designed to with
stand all kinds of loads
In the Power Series, the control components are
designed to withstand all types of loads. These include
loads such as; resistive, capacitive, non-linear,
high-density discharge lamps, induction motors, speed
drives etc. This makes the UPS extremely compatible
with many types of electronics. Better yet, the UPS
comes with a wide array of parameters that can be
programmed locally or remotely to fit different types of
environment.
With the use of simple algorithms, an estimated
remaining back-up time can be calculated and
indications will be reflected on a LCD panel.
5.7” Multiple Languages Graphical LCD
Display
Our team of specialists has gathered together to
revolutionize the UPS usability by adding in a 5.7” LCD
monitor display with all information and alarm
notifications viewable within a single display.
N+1 Redundancy
A parallel redundant system allows 4 UPS models to
operate in parallel and as backup for each other.
35
Online UPS
Power Series
Online Power E Series
10kVA – 120kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PROLiNK UPS Power E Series (3P/3P) three-phase input / three-phase output, true online
double conversion UPS system guarantees to supply consistent and quality electrical power
to protect your mission critical applications such as data centres, medical equipments and call
centres. Power E Series give excellent output leading power factor up to 0.9 leading for 100%
load. Harmful effects of harmonic injection are eliminated with the employment of Adaptive
Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic
distortion and high input power factor, it is able to lower installation costs by utilizing smaller
cables and miniature circuit breakers (MCB).
Our team of specialists has gathered together to revolutionize the UPS usability by adding in a
5.7” LCD monitor display with all information and alarm notifications viewable within a single
display. To ensure our products are user centered, our group of specialist has also adopted a
front access concept to create a UPS system that is easy for users to carry out preventative
maintenance and replacement activities. In addition, this device comes with a parallel
redundant system that allows four UPS models to operate in parallel. An option of an
additional isolation transformer is also available to suit your requirements. The Power series is
available in models ranging from 10kVA to 120kVA.
• Online double conversion technology with DSP control
• Output power factor 0.9
• Advanced control with Adaptive Feed Forward
Cancellation (AFC) technology for very low
• Very low input current distortion (THDi < 1%)
• Input power factor 0.99 at 10% load
• Output efficiency up to 95%
• Space-saving compact design
• Over 60% materials recyclable
• Remaining backup time calculation
• Remaining backup time calculation
• Front access makes maintenance and replacement
easily
• Highly flexibility in single phase/ three-phase set-ups
• Parallel redundant operation with up to 4 units
• Variety of communications and options available
• Flexible battery type configuration by request
(only available for Taurus Pro 400V models)
• Long-run models available for 400V 10KVA-40KVA
and 208V 7.5KVA-20KVA
1
Rear Panel (Internal)
1
For 10kVA to 80kVA model
3
10
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
1
2
3
3
10
10
2
2
4
4
4
5
6 7
8
5 6
5 6 7
7
8
8
9
9
9
PRO73310ES
PRO73315ES
PRO73320ES
PRO73330ES
PRO73340ES
PRO73360ES
PRO73380ES
36
Online UPS
1
For 100kVA to 120kVA model
2
3
10
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
4
5
6
7
8
9
PRO733100ES
PRO733120ES
Full Specifications
MODELS
PRO73310ES
PRO73315ES
PRO73320ES
PRO73330ES
PRO73340ES
PRO73360ES
PRO73380ES
60kVA
80kVA
3-phase in / 3-phase out
Phase
10kVA
Capacity
15kVA
20kVA
30kVA
INPUT
Nominal Voltage
40kVA
3 x 400V (3Ph + N)
Acceptable Voltage Range
+15% or –20%
Frequency
50 / 60 Hz ±5 %
Current Limitation
High overload: PFC Limit (discharging batteries)
1.0
Power Factor
< 1.5% @ 100% load;
< 2.5% @ 50% load;
< 6.0% @ 10% load
Total Harmonic Distortion (THDi)
< 1.0% @ 100% load;
< 2.0% @ 50% load;
< 5.0% @ 10% load
INVERTER
Nominal Voltage
3 x 400V (3Ph + N)
Precision
Frequency
Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed
±10 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
< 0.5% (Linear Load) ; < 1.5% (Non-linear Load)
Phase Displacement
120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)
Dynamic Recovery Time
10 ms. at 98 % of the static value
Admissible Overload
Admissible Crest Factor
Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s
Admissible Power Factor
0.7 inductive to 0.7 capacitive
Imbalance Output Voltage
@ 100%Unbalanced Load
<1%
3.4 : 1
3.2 :1
2.8 : 1
High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit
Current Limit
STATIC BYPASS
Type
Solid state
Voltage
3x400V (3Ph + N)
50/60 Hz
Frequency
Microprocessor control
Activation Criterion
Zero
Transfer Time
400% for 10 sec.
Admissible Overload
Immediate, for overloads above 150%
Transfer to Bypass
Automatic after alarm clear
Retransfer
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 x 400V (3Ph + N)
50/60 Hz
Frequency
Overall Efficiency (Line mode)
90%
90.5%
91%
92%
92.5%
12V 4.5Ah
12V 4.5Ah
12V 7Ah
12V 9Ah
12V 12Ah
5
3
5
93%
94%
BATTERY
Built-in Battery Type (2x31)
Back-up Time (minutes)
Max. Charging Current
3
Not Applicable
3
23.5 A
47 A
70.5 A
PHYSICAL
Dimension (mm) D x W x H
770 x 450 x 1100
805 x 590 x 1320
Net Weight (without batteries) (kgs)
78
86
94
110
122
Net Weight (w/built-in batteries) (kgs)
178
186
249
290
357
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
162
231
Not Applicable
37
Online UPS
MODELS
PRO733100ES
PRO733120ES
3-phase in / 3-phase out
Phase
100kVA
Capacity
120kVA
INPUT
Nominal Voltage
3 x 400V (3Ph + N)
Acceptable Voltage Range
+15% or –20%
Frequency
50 / 60 Hz ±5 %
Current Limitation
High overload: PFC Limit (discharging batteries)
1.0
Power Factor
< 1.5% @ 100% load;
< 2.0% @ 50% load;
< 6.0% @ 10% load
Total Harmonic Distortion (THDi)
INVERTER
Nominal Voltage
3 x 400V (3Ph + N)
Precision
Frequency
Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed
±10 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
Phase Displacement
< 0.5% (Linear Load) ; < 1.5% (Non-linear Load)
120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)
Dynamic Recovery Time
10 ms. at 98 % of the static value
Admissible Overload
Admissible Crest Factor
Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s
Admissible Power Factor
0.7 inductive to 0.7 capacitive
Imbalance Output Voltage
@ 100%Unbalanced Load
<1%
3.2 :1
High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit
Current Limit
STATIC BYPASS
Type
Solid state
Voltage
3x400V (3Ph + N)
50/60 Hz
Frequency
Microprocessor control
Activation Criterion
Zero
Transfer Time
400% for 10 sec.
Admissible Overload
Immediate, for overloads above 150%
Transfer to Bypass
Automatic after alarm clear
Retransfer
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 x 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency (Line mode)
93%
93.3%
70.5 A
188 A
BATTERY
Max. Charging Current
PHYSICAL
Dimension (mm) D x W x H
Net Weight (without batteries) (kgs)
Net Weight (w/built-in batteries) (kgs)
805 x 590 x 1320
255
Not Applicable
Options
• SNMP Card for data communication via network connection
• MODBUS Card (Communication interface)
• Output Isolation Transformer
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
38
Online UPS
The Power Series is designed with the new state of art
transformerless PWM technology that can be easily
adapted to any kinds of complicated loads such as the
non-linear systems (IT systems), highly inductive/
capacitive loads, high-density discharge lamps and
induction motors. The Power series is designed with 2
important criterions in mind; maximum efficiency and
energy conservation. The unit also comes with a small
form factor to allow for minimum installation effort.
Furthermore, a parallel redundant system is integrated to
allow two UPS models to operate in parallel as backup
for each other. The Power Series is available in
capacities ranging from 15 to 120kVA.
Online Double Conversion Technology with
DSP Control
The Power Series is able provide a higher load up-time
and effective insulation against network disturbance
with its online double conversion technology. A Digital
Signal Processor (DSP) controller improves the
performance and efficiency of the UPS.
Input Power Factor 0.99 At 10% Load
Lower power losses would result in reduced
consumption, lower operation and maintenance costs.
INPUT POWER FACTOR
1,20
1,00
0,80
PFin
The Most Versatile Solution For Power
Protection
0,60
0,40
0,20
0,00
0%
25%
50%
LOAD
Output Efficiency of up to 95%
Designed with a DSP controller and fourth generation
IGBT transistors, the UPS is able to achieve extremely
high efficiency of up to 95%. With such high ratings,
components in the UPS are not only protected but also
prolonged due to the decrease in heat losses.
SERIES TIPICAL EFFICIENCY
100%
Advanced Control with Adaptive Feed Forward
Cancellation (AFC) Technology
By cancelling both the input current and the output
voltage harmonics, the harmful effects of harmonic
injection can be eliminated and this enhances the load
integrity.
Low Input Current Distortion (THDi < 1%)
AFC cells are used to achieve extremely low distortion
values. The Power series is able to obtain a low input
current distortion at THDi < 1% under full load and a THDi
< 5% under smaller load (i.e. 10% of load). This will
prevent distortion of electrical network upstream and
thus, result in the reduction of cable usage and protective
devices in the electrical network.
EFFICIENCY
75%
50%
25%
0%
0%
25%
50%
LOAD
Small Form Factor
Utilizes a transformerless technology allows the design
of the UPS to be lighter and smaller.
Output Power Factor
Nowadays IT installation requirements are driving to
power sources able to supply loads with leading power
without affecting the power capability. Power E Series
UPS are able to supply full power without any derating
for all loads from 0.9 lagging to 0.9 leading. This unique
characteristic avoids any UPS over sizing in case of unity
or leading power factor as for the loads.
39
Online UPS
Front Access concept
An important consideration has
been given during the UPS design
phase to create a system that
allows users to access the
unit’s electronic cards and power
components
with
minimum
effort. All electronic boards and
components can be accessed
from the front panel for easy
maintenance and replacement
activities.
Variety Of
Available
Communications
And
Option
The UPS has provided the following standard
communication selections:
• Relay interface
• RS-232/485 port
• 1 × SNMP slot
• Modbus RTU / SEC protocol
• 2 × connectors for parallel connection
Made of 60% Recyclable
Materials
Versatile Single-Phase / Three-Phase set-ups
This highly versatile UPS is designed with different types
of setting-up options;
• Three-phase input / Three-phase output (III/III)
• Three-phase input / Single phase output (III/I)
When it comes to conserving the
environment, PROLiNK is committed to
play a part by designing their UPS
products using recyclable materials.
Back-up Time indicator
Control Components are designed to with
stand all kinds of loads
In the Power Series, the control components are
designed to withstand all types of loads. These include
loads such as; resistive, capacitive, non-linear,
high-density discharge lamps, induction motors, speed
drives etc. This makes the UPS extremely compatible
with many types of electronics. Better yet, the UPS
comes with a wide array of parameters that can be
programmed locally or remotely to fit different types of
environment.
With the use of simple algorithms, an estimated
remaining back-up time can be calculated and
indications will be reflected on a LCD panel.
5.7” Multiple Languages Graphical LCD
Display
Our team of specialists has gathered together to
revolutionize the UPS usability by adding in a 5.7” LCD
monitor display with all information and alarm
notifications viewable within a single display.
N+1 Redundancy
A parallel redundant system allows 4 UPS models to
operate in parallel and as backup for each other.
40
Online UPS
PPM Series
PROLiNK Power
Modular (PPM)
UPS System
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PROLiNK PPM Series modular three-phase input / three-phase output online
double conversion UPS takes scalability to a whole new level. Based on a scalable
design, the PPM comes with a wide range of capacity, ranging from as low as
30kVA to as high as 210kVA. The PPM series is designed with a N+X parallel
redundancy system that allows two or more UPS modules to operate in parallel
and as back-up for each other. This unit provides an ideal protection for data
centers, telecommunication facilities and other critical applications. Up to seven
30kVA modules can be fitted into a standard cabinet to simplify maintenance and
replacement activities. The PPM Series guarantees a low mean-time-to-repair
(MTTR), giving users a shorter elapsed time between the point of repair and the
point of equipment recovery.
• High efficiency online double conversion technology
• High scalability
• Unity output power factor
• Modular design lowers MTTR
• N+1 or N+X parallel redundancy for power guarantee
• Ease of installation and maintenance
• Flexible battery configuration adapts different applications
• Adjustable charging current
• High overload capability
• Graphic 5.7” LCD design for easy management
High Efficiency Online Double Conversion
Technology
High Scalability
PROLiNK PPM is designed with the latest online double
conversion technology that provides a high efficiency
rating of 96%. With such a high efficiency rating, the PPM
can save you hundreds of dollars each year.
Based on a scalable design, the PPM Series simplifies
future expansion by making UPS units easily upgradable.
This architecture allows you to meet power demands by
adding additional modules vertically in a single rack
enclosure.
Unity Output Power Factor
Modular Design Lowers MTTR
With a unity output factor (kVA = kW), the PROLiNK
PPM UPS system is 100% compatible with today's high
power factor loads. It is able to meet the latest
server requirements, giving the best value for your IT
investments.
The modular design ensures uninterrupted power supply
during UPS maintaining and replacing activities. Also, the
PPM Series guarantees a low mean-time-to-repair
(MTTR), giving users a shorter elapsed time between the
point of repair and the point of equipment recovery.
41
Online UPS
N+X Parallel Redundancy
Ease Of Installation and Maintenance
The PPM series is designed with a N+X parallel
redundancy system that allows two or more UPS
modules to operate in parallel and as back-up for each
other.
With a built-in maintenance bypass feature, the UPS is
able to deliver continuous power to the critical load
during maintenance. Better yet, the PPS comes with a
front access concept to facilitate installation.
Adjustable Charging Current
PROLiNK PPM comes with a maximum charging current
of up to 8A for each individual module. The charging
current can be adjusted based on the necessary
requirement.
High Overload Capability
PROLiNK PPM supports 110% overload for 60 minutes,
120% for 10 minutes and 150% for 1 minute.
5.7” LCD Graphic Mimic Panel
A multilingual 5.7" graphic
LCD screen is integrated as
part of the design to provide
users with visual information
and
advanced
control
abilities.
PPM90
The PROLiNK PPM90 is a compact stand alone UPS system that provides the
best backup solution for small and medium loads. This unit comes with a
standard EIA height of 30U and is able to fit capacities ranging from 30kVA to
90kVA in the same cabinet. With features such as N+1 redundancy and the
capability for future expansion, the PROLiNK PPM90 is definitely able to make
your backup experience an absolute cinch.
No. Of Module
Capacity
1
30kVA
2
60kVA
3
90kVA
Dimension
600 x 1100 x 1485 (30U) mm
Exterior
Interior
Exterior
Interior
PPM210
The PROLiNK PPM210 is a standalone UPS system that comes with a standard
EIA height of 42U. This unit is able to fit 7 x 30kVA modular redundancy in the
same cabinet. Even better, the PPM210 has the capability to manage future
capacity expansion of up to 210kVA, making the PPM210 the best backup
solution for greater loads.
No. Of Module
Capacity
1
30kVA
2
60kVA
3
90kVA
4
120kVA
5
150kVA
6
180kVA
7
210kVA
Dimension
600 x 1100 x 2030 (42U) mm
42
Online UPS
Full Specifications
MODELS
PPM30
PPM60
PPM90
Phase
PPM120
PPM150
PPM180
PPM210
3-phase in/3-phase out
Total Capacity*
UPS Power Modules
30KW
60KW
90KW
120KW
150KW
180KW
210KW
1
2
3
4
5
6
7
Topology
True Double-Conversion Online
INPUT
Nominal Voltage
Voltage Range
3 x 400 VAC (3Ph+N)
305 ~ 477 Vac @Full load, 208 ~ 477 Vac @ <70% load
50/60Hz (auto-selectable)
Nominal Frequency
40Hz ~70Hz
Frequency Range
> 0.99 @ 100% Load , >0.98 @ 50% Load
Power Factor
< 3% @ 100% load
Harmonic Distortion (THDi)
OUTPUT
Nominal Voltage
Voltage Regulation (Steady state)
3 x 400 VAC (3Ph+N)
≦± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)
≦± 5% Typical
Voltage Regulation (Transient)
Nominal Frequency
50/60Hz
Frequency Range (Synchronized)
46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability
1 hour for 110%, 10 mins for 120%, ; 1 min for 150%, 200ms for >150%
Harmonic Distortion
≦1.5% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Efficiency
>94.5%
BATTERY / CHARGER
Nominal Voltage
+/- 216V (12V x 36 pcs)
Maximum Voltage
+/- 240V (12V x 40 pcs)
Minimum Voltage
+/- 192V (12V x 32 pcs)
Float Charging Voltage
2.25V / Cell
Boost Charging Voltage
2.35V / Cell
Temperature Compensation
Yes
Maximum Charging Current
8A (User-adjustable)
PHYSICAL
Medium Size (mm) D x W x H
Full Size (mm) D x W x H
1100 x 600 x 1485 (30U)
Not Applicable
1100 x 600 x 2030 (42U)
ENVIRONMENT
Operation Temperature
Relative Humidity
0 ~ 40°C
0 ~ 95% non-condensing
Altitude
<1000m for Nominal power
IP Class
IP 20
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
STANDARDS
Safety
EMC
IEC/EN 60950-1; IEC/EN 62040-1
IEC/EN 62040-2 Category C3
When temperature above 30°C, the system output power factory will become 0.8
One power module provides 30kW power capacity. One battery module contains 10 pcs of 12V7Ah, 12V9Ah or 12V10Ah (subject to requirement) Valve Regulated Lead Acid batteries.
All specifications, designs and contents are subjected to changes without prior notice.
43
Online UPS
PRO-R Series
1U Online UPS 1000VA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PROLiNK PRO-R is a transformerless Online UPS that is designed with a small footprint. Despite being thinner and
lighter, the PRO-R is able to provide similar performance as any other online UPS. Built with a true online
double-conversion technology, it guarantees consistent and clean electrical power to fully protect your mission-critical
devices.
In addition, the UPS comes with a built-in master and slave feature to conserve energy when the master device is no
longer drawing current. PROLiNK PRO-R works with a variety of applications such as servers, networking and IP
telephone systems.
• True double conversion online topology
• Microprocessor control optimizes reliability
• Output power factor 0.8
• Input power factor correction
• ECO mode for energy saving
• Built-in serial communication port/Dry contact
Rear Panel
For PRO1000RS
1.
2.
3.
4.
5.
Ac Input
Output Receptacles: Connect to Mission-critical Loads
USB/ RS-232 Serial Communication Port
ROO/ PRO Function Connector
SNMP Intelligent Slot
1
2
4
3
5
IPS1000RS
For PRO1000RL
1.
2.
3.
4.
5.
6.
7.
Ac Input
Output Receptacles: Connect to Mission-critical Loads
USB/ RS-232 Serial Communication Port
ROO/ PRO Function Connector
SNMP Intelligent Slot
Dry Contact
External Battery Connector
5
6
7
2
1
4
IPS1000RL
44
Online UPS
Full Specifications
MODELS
PRO1000RS
PRO1000RL
Capacity
1000 VA
1000 VA
110/120 VAC or 220/230/240 VAC
220/230/240 VAC
55-150 VAC or 110-300 VAC @ 50% load
80-150 VAC or 160-300 VAC @ 100% load
110-300 VAC
INPUT
Voltage
Acceptable Voltage Range
Frequency Range
60/50 Hz (Auto sensing)
OUTPUT
Output Voltage
110/120 VAC or 220/230/240 VAC
Voltage Regulation
Frequency Range
50/60 ± 0.5% Hz
Frequency Range (Batt. Mode)
5:1 (110/120 VAC)
3:1 (220/230/240 VAC)
Current Crest Ratio
3:1
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Harmonic Distortion
Transfer Time
220/230/240 VAC
±1%
40-70 Hz (50/60Hz Auto sensing)
AC Mode to Batt. Mode
0ms
Inverter to Bypass
4 ms (Typical)
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
86%
Battery Mode
83%
BATTERY
Battery Type
Sealed Lead-acid battery
Battery Spec & Numbers
Typical Recharge Time
INDICATORS
6 V / 7 Ah x 4
Back to 90% capacity in 4 hours
LED
Lithium-ion battery or Sealed Lead-acid battery
Battery Spec & Numbers (Battery voltage: 48VDC)
Depending on external battery capacity
AC mode, Battery mode, and fault indicators
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
ENVIRONMENT
477 x 438 x 44
300 x 440 x 44
13
6
Humidity
20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level
Less than 50dBA @ 1 Meter
MANAGEMENT
USB or RS-232
Dry Contact (Option)
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Signal for AC Power Normal, Battery OK and Fault Alarm
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
45
Online UPS
PRO-M Series
Online UPS
1kVA - 6kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PRO-M Series is a true online double-conversion UPS system that
provides clean and consistent electrical power to those who experience
underserved power supply. It is designed with a wide input voltage range
to handle voltage fluctuating situations to fail-safe your equipment.
The PRO-M Series is noticeably compact in size and is ideal for ATMs,
banking and other business critical applications. Users can also adjust the
charging current from 1A to 6A to suit their requirements.
•
•
•
•
•
•
•
•
•
True double-conversion
Microprocessor control optimizes reliability
Output power factor 0.8
Wide input voltage (110 V – 300 V)
Converter mode available
ECO mode for energy saving (Only available for 1-3KVA)
Generator compatible
Smart SNMP works well with either USB or RS-232
Comprehensive display allows easy monitoring and access of UPS status
3
4
Rear Panel
AC input
Input circuit breaker
USB communication port
RS-232 communication port
SNMP intelligent slot (optional)
External battery connection (only available for EML model)
Output receptacles
Output circuit breaker
Output terminal
5
4
6
For 1kVA to 2kVA model
1.
2.
3.
4.
5.
6.
7.
8.
9.
3
5
7
2
2
1
7
1
PRO801M
5
3
PRO801ML
4
3
5
4
7
2
2
1
7
1
PRO802M
PRO802ML
46
Online UPS
For 3kVA model
1.
2.
3.
4.
5.
6.
7.
8.
9.
3
AC input
Input circuit breaker
USB communication port
RS-232 communication port
SNMP intelligent slot (optional)
External battery connection (only available for EML model)
Output receptacles
Output circuit breaker
Output terminal
4
5
3
7
9
2
7
2
9
1
1
PRO803M
For 5kVA to 10kVA model
1.
2.
3.
4.
5.
External battery connector
RS-232 communication port
Intelligent slot
USB communication
Emergency power off function connector
(EPO connector)
6. Cooling fan
7. Input circuit breaker
8. Input/ Output terminal
(Refer to diagram 3 for the details)
9. Maintenance bypass switch (option)
10. Output terminal
11. Grounding terminal
12. Utility input terminal
5
4
4
2
1
6
PRO803ML
3
5
9
4
2
6
7
1
3
5
6
9
8
6
7
8
11
10
PRO805M / PRO806M /
PRO810M
12
PRO805ML /
PRO806ML /
PRO810ML
47
Online UPS
Full Specifications
MODELS
Phase
PRO801M/ ML
PRO802M/ ML
Capacity
1000 VA
2000 VA
INPUT
Nominal Voltage
Input Voltage Range
PRO803M/ ML PRO805M/ ML
Single phase with ground
3000 VA
PRO806M/ ML
PRO810M/ ML
6000 VA
10000 VA
5000 VA
100/110/115/120/127VAC or 200/208/220/230/240VAC
208/220/230/240VAC
55-150 VAC or 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%)
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
40 Hz ~ 70 Hz
46~54 Hz or 56~64 Hz
Frequency Range
≧ 0.99 @ Nominal Voltage (100% load)
Power Factor
OUTPUT
Output Voltage
100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation
47~ 53 Hz or 57 ~ 63 Hz
46~54 Hz or 56~64 Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
50 Hz or 60Hz ± 0.1 Hz
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
3:1
Current Crest Ratio
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Harmonic Distortion
Transfer Time
208/220/230/240VAC
±1%
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Zero
AC to DC
4 ms (Typical)
Inverter to Bypass
Zero
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
88%
Battery Mode
90%
83%
85%
2
4
89%
88%
92%
93%
90%
91%
BATTERY
Battery Type
12 V / 9 Ah
Numbers
Standard Model
27.4VDC ± 1%
54.7 VDC ±1%
82.1 VDC ±1%
115.2 VDC ±1%
273VDC
±1%
218.4 VDC ±1%
Depending on the capacity of external batteries
2
3
4
Charging Current
Charging Voltage
20
1A/2A
Battery Type
Long-Run Model
16
Back to 90% capacity in 9 hours
1A
Charging Current
Numbers
8
Back to 90% capacity in 4 hours
Recharge Time (Typical)
Charging Voltage
6
6
8
6
8
1A/2A/4A/6A (Adjustable)
27.4
VDC
± 1%
41.0
VDC
± 1%
54.7 82.1 109.4
VDC VDC VDC
±1% ±1% ±1%
82.1
VDC
±1%
109.4
VDC
±1%
115.2 VDC ±1%
16
20
1A/2A/4A/6A (Adjustable)
1A/2A/4
(Adjustable)
218.4 VDC ±1%
273 VDC
±1%
INDICATORS
LCD Display
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 442 x 190 x 688 369 x 190 x 688
Net Weight (kgs)
9.8
17
Dimension (mm) D × W × H 282 x 145 x 220
Net Weight (kgs)
4.1
27.6
397 x 145 x 220
6.8
7.4
43
61
442 x 190 x 318 369 x 190 x 318
15
12
442 x 190 x 688
66
75
442 x 190 x 318
16
18
ENVIRONMENT
Humidity
Noise Level
20-90 % RH @ 0- 40°C (Non-condensing)
0-95% RH@0-40°C 0-95% RH@0-50°C
(Non-condensing) (Non-condensing)
0-95% RH @ 0-40°C
(Non-condensing)
Less than 50dBA @ 1 Meter
Less than 58dBA Less than 55dBA
@ 1 Meter
@ 1 Meter
Less than 58dBA
@ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
48
Online UPS
PRO-EM Series
Online UPS
1kVA - 10kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PRO-EM Series is a true online double-conversion UPS system that
provides clean and consistent electrical power to those who experience
underserved power supply. It is designed with a wide input voltage range
to handle voltage fluctuating situations to fail-safe your equipment.
Also, the UPS provides better output factor of up to 0.9 and is ideal for
ATMs, banking and other business critical applications. PRO-EM Series
comes with standard USB and RS-232 communication ports and a
built-in intelligent slot for additional options such as adapters, protocol
converters and relay contact cards.
• True double-conversion
• Microprocessor control optimizes reliability
• Input power factor correction
• Output power factor 0.9
• Wide input voltage
• Converter mode available
• ECO mode for energy saving only available for 1-3KVA models
• Generator compatible
• Smart SNMP works well with either USB or RS-232
• Comprehensive display allows easy monitoring and access of UPS status
Rear Panel
For 1kVA model
1.
2.
3.
4.
5.
6.
7.
AC input
Input circuit breaker
USB communication port
RS-232 communication port
SNMP intelligent slot (optional)
External battery connection (only available for EML model)
Output receptacles
5
3
4
3
5
4
6
7
2
2
1
1
PRO801EM
7
PRO801EML
49
Online UPS
For 2kVA to 3kVA model
1.
2.
3.
4.
5.
6.
7.
8.
9.
5
AC input
Input circuit breaker
USB communication port
RS-232 communication port
SNMP intelligent slot (optional)
External battery connection (only available for EML model)
Output receptacles
Output circuit breaker
Output terminal
4
3
3
5
4
6
7
2
2
7
1
1
PRO802EM
4
3
PRO802EML
3
5
4
5
6
7
9
2
9
2
7
1
1
PRO803EM
PRO803EML
For 6kVA to 10kVA model
1.
2.
3.
4.
5.
External battery connector
RS-232 communication port
Intelligent slot
USB communication
Emergency power off function connector
(EPO connector)
6. Cooling fan
7. Input circuit breaker
8. Input/ Output terminal
9. Maintenance bypass switch (optional)
10. Output terminal
11. Grounding terminal
12. Utility input terminal
4
2
1
3
5
9
6
6
7
8
4
2
3
1
5
9
6
6
7
8
11
10
PRO810EM
12
PRO810EML
50
Online UPS
Full Specifications
MODELS
Phase
PRO801EM/ EML
PRO802EM/ EML
Capacity
1000 VA
2000 VA
INPUT
Nominal Voltage
PRO803EM/ EML
PRO806EM/ EML
Single phase with ground
3000 VA
PRO810EM/ EML
10000 VA
6000 VA
100/110/115/120/127VAC or 200/208/220/230/240VAC
208/220/230/240VAC
60-150 VAC or 120-300 VAC at 50% load
90-140 VAC or 180-280 VAC at 100% load
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
40 Hz ~ 70 Hz
46~54 Hz or 56~64 Hz
Input Voltage Range
Frequency Range
≧ 0.99 @ Nominal Voltage (100% load)
Power Factor
OUTPUT
Output Voltage
100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
47~ 53 Hz or 57 ~ 63 Hz
46~54 Hz or 56~64 Hz
50 Hz or 60Hz ± 0.5%
50 Hz or 60Hz ± 0.1 Hz
3:1
Current Crest Ratio
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Harmonic Distortion
Transfer Time
208/220/230/240VAC
±1%
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Zero
AC to DC
4 ms (Typical)
Inverter to Bypass
Zero
Pure Sinewave
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
88%
89%
90%
Battery Mode
83%
85%
88%
2
4
94%
90%
91%
16
20
BATTERY
Battery Type
Numbers
Standard Model
12 V / 9 Ah
Recharge Time (Typical)
Back to 90% capacity in 9 hours
1.0A
1A, 2A (Adjustable)
Charging Current
Charging Voltage
27.4VDC ± 1%
Battery Type
Long-Run Model
Numbers
Charging Current
Battery Type
6
Back to 90% capacity in 4 hours
2
27.4VDC ± 1%
54.7 VDC ±1%
82.1 VDC ±1%
218.4 VDC ±1%
Depending on the capacity of external batteries
4
1A/2A/4A/6A
54.7 VDC ±1%
6
82.1 VDC ±1%
273 VDC ±1%
16
20
1A, 2A, 4A (Adjustable)
218.4 VDC ±1%
273 VDC ±1%
INDICATORS
LCD Display
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W × H
Net Weight (kgs)
Dimension (mm) D × W × H
Net Weight (kgs)
282 x 145 x 220
397 x 145 x 220
421 x 190 x 318
369 x 190 x 688
9.8
17
27.6
61
76
282 x 145 x 220
397 x 145 x 220
397 x 145 x 220
369 x 190 x 318
442 x 190 x 318
4.1
6.8
7.4
12
16
20-90 % RH @ 0- 40°C (Non-condensing)
0-95% RH@0-50°C
(Non-condensing)
0-95% RH @ 0-40°C
(Non-condensing)
Less than 50dBA @ 1 Meter
Less than 55dBA
@ 1 Meter
Less than 58dBA
@ 1 Meter
442 x 190 x 688
ENVIRONMENT
Humidity
Noise Level
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
51
Online UPS
Giant Series
Online UPS
30kVA - 80kVA
Local Area Telecommunication
Network
Devices
(LAN)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
PROLiNK Giant Series (3P/3P) three-phase input/ three-phase output,
true online double conversion UPS system guarantees to supply
consistent and quality electrical power to protect your mission critical
applications. The front access design makes it easy for users to perform
maintenance and replacement activities.
A parallel redundant system is implemented in the Giant Series to provide
adequate power supply in the event where a single module fails or needed
to be taken offline for service. The Giant Series (3P/3P) also comes with a
built-in transformer to provide 100% protection against unexpected AC
power problems.
• True double-conversion
• Microprocessor control optimizes reliability
• Input power factor correction
• Output power factor 0.9
• Wide input voltage
• Converter mode available
• Generator compatible
• Smart SNMP works well with either USB or RS-232
• Comprehensive display allows easy monitoring and access of UPS status
1
Rear Panel
For 30kVA to 80kVA model
Intelligent slot
Output circuit breaker
Input circuit breaker
Emergency power off function connector
(EPO connector)
5. USB communication
6. RS-232 communication port
7. RS-485 communication port
8. Parallel connection
9. AC input
10. Bypass
11. Maintenance bypass
12. AC output
13. Battery
2
3
5 4
6
7
1
2
3
5 4
6
7
1.
2.
3.
4.
8
8
9
9
10
10
11
12 13
11 12 13
PRO633030S / PRO633040S
PRO633060S / PRO633080S
52
Online UPS
Full Specifications
MODELS
PRO633030S
PRO633040S
PRO633060S
PRO633080S
Capacity
30 kVA
40 kVA
60 kVA
80 kVA
INPUT
Nominal Voltage
Acceptable Voltage Range
3 x 380VAC/400VAC (3Ph + N)
304VAC ~ 440VAC
50/60 Hz ± 10 %
Frequency
INVERTER
Nominal Voltage
3 x 380VAC/400VAC (3Ph + N)
Precision
Stationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency
50/60 Hz synchronised ±1 %
With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)
Phase Displacement
1 cycle at 98 % of the static value
Dynamic Recovery Time
Admissible Overload
110% for 60min,125% for 10 min, 150% for 60s
Admissible Crest Factor
3:1
Admissible Power Factor
0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
High overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
Current Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
Transfer to Bypass
200% for 10 sec
Immediate, for overloads above 150%
Automatic after alarm clear
Retransfer
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 x 400V (3Ph + N)
50/60 Hz
Frequency
Overall Efficiency
Overall Efficiency
90%
Low Battery
95%
BATTERY & CHARGER
Battery Type and Numbers
12V x 30 pcs, sealed lead acid battery
360 VDC
Nominal Battery Voltage
Charging Method
CC/CV
Precision
±1%
Charging Current
40 A
Charging Voltage
405 VDC
PHYSICAL
Dimensions, D x W x H(mm)
Net Weight (Kgs)
847.5 x 432.4 x 1134.5
271.5
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specifications, designs and contents are subject to change without prior notice.
1054 x 508 x 1287
298
462
532
53
Online UPS
Jupiter Series (3P/3P)
Online Jupiter Series
10kVA - 320kVA
Key Features
• True Galvanic Isolation technology designed to provide full protection against high voltage surges, noise and leakage
current etc
• Plug and Play modular design allows users to carry out maintenance and repair works effortlessly
• Cold start function
• Multi-CPU design
• Hot-swappable battery design
• Temperature compensation for battery charging
• Wide input voltage range
• Output power factor of 0.80
• Software and Hardware redundant design
• EMI suppression provides approximately 200dB noise reduction
• Static Bypass Switch provides automatic transfer to a back-up power source in the event of a failure within the UPS
• Maintenance Bypass Switch
• Smart battery charger designed to optimize battery performance
• LCD User Interface
Options
• Remote control panel
• PC monitoring software
• Auto dialling module
• SNMP/ HTTP network card
• Emergency Power Off switch (EPO)
54
Online UPS
Full Specifications
10KVA ~ 60KVA UPS 3-Phase Input / 3-Phase Output
MODELS
PRO533010S
PRO533020S
PRO533030S
PRO533040S
PRO533050S
PRO533060S
Capacity
10kVA
20kVA
30kVA
40kVA
50kVA
60kVA
INPUT
Input Voltage
380 / 400 / 415VAC 3 Phase 4 Wire
Input Range
307 – 520V
Input Frequency
50 / 60Hz +/- 7%
Input Power Factor
0.8
Normal Input Current(A)
18
36
54
72
90
108
Maximum Input Current(A)
24
45
68
90
113
136
135
162
25
30
Power Walk In
0% - 100% : 20 sec
Efficiency
99%
1%
Voltage Regulation
27
Current Limit(A)
54
81
Ripple Voltage
108
0.5%
BATTERY
Type
Seal Lead Acid / NiCd
No. Of Cells
174 / 271
Voltage Range
Maximum Charge Current (Adc)
5
10
295 – 410VDC / 285-415VDC
15
20
Battery Low Voltage
320VDC / 305VDC
Battery Low Stop
295VDC / 285VDC
Boost Charge
402VDC / 415VDC
Float Charge
390VDC / 410VDC
INVERTER
285 – 420VDC
Dc Input Range
Wave Form
Sinusoid
Output Voltage
380 / 400 / 415 VAC 3 Phase 4 Wire
Output Power Factor
0.8
+/-1%
Voltage Regulation 100% Unbalance Load
Frequency Lock Range
45 – 55Hz / 55 – 65Hz
50 / 60Hz + / - 0.1Hz
Output Frequency (Free Running)
Phase Shift Under 100% Unbalance Load
120 % + / - 0.5°
<2%
THD (Linear Load)
Overload
<110%
110 - 125%
Continuous
15 min
125 - 150%
>150%
10 min
60 sec
Efficiency (100% Load)
93%
Maximum Output Peak Current(A)
43
87
93.5%
130
174
94%
218
260
STATIC SWITCH
Voltage Range
173 – 277 VAC (Line To Neutral)
Frequency Range
45 – 55Hz / 55 – 65Hz
Efficiency
Transfer Time
Overload
99.5%
Mains > Inverter
0 ms
0 ms
Inverter > Mains
100%
30 sec
300%
1 sec
Yes
Isolation With Output
OVERALL CHARACTERISTICS
91%
Overall Efficiency
91.5%
92%
OPERATING ENVIRONMENT
Temperature
0 – 40°F ( 32 – 104°F )
0% - 90% ( Non–condensing )
Humidity
<1500m Above Sea Level
Altitude
Maximum Heat Dissipation(Kw)
0.65
1.3
1.9
2.6
3
3.5
Weight(Kg) (No Battery)
270
300
400
480
550
680
Dimension (mm) D x W x H
800 x 550 x 1600
Audible Noise
< 65 dBA (@ 1 m)
Standards
Protections
En50091-1,-2
Yes
Short Circuit
Rectifier, Reserve, Bypass Nfb
Lightning
Mov
Emc Filter
Input & Output
Galvanic Isolation
Between Input & Output
Yes
Data Display By Lcd
Indications & Alarms
Yes
Fcc Class A
LED,LCD,BUZZER
Yes
Dry Contact
Yes
Battery Start
Yes
55
Online UPS
80KVA ~ 160KVA UPS 3-Phase Input / 3-Phase Output
MODELS
PRO533080S
PRO533100S
PRO533120S
PRO533160S
Capacity
80kVA
100kVA
120kVA
160kVA
INPUT
Input Voltage
380 / 400 / 415VAC 3 Phase 4 Wire
Input Range
307 – 520V
Input Frequency
50 / 60Hz +/- 7%
Input Power Factor
0.8
Normal Input Current(A)
144
180
216
288
Maximum Input Current(A)
180
225
270
360
324
432
295 – 410VDC / 285-415VDC
50
60
80
Power Walk In
0% - 100% : 20 sec
Efficiency
99%
Voltage Regulation
1%
216
Current Limit(A)
270
Ripple Voltage
0.5%
BATTERY
Type
Seal Lead Acid / NiCd
No. Of Cells
174 / 271
Voltage Range
Maximum Charge Current (Adc)
40
Battery Low Voltage
320VDC / 305VDC
Battery Low Stop
295VDC / 285VDC
Boost Charge
402VDC / 415VDC
Float Charge
390VDC / 410VDC
INVERTER
285 – 420VDC
Dc Input Range
Wave Form
Sinusoid
Output Voltage
380 / 400 / 415 VAC 3 Phase 4 Wire
Output Power Factor
0.8
+/-1%
Voltage Regulation 100% Unbalance Load
Frequency Lock Range
45 – 55Hz / 55 – 65Hz
50 / 60Hz + / - 0.1Hz
Output Frequency (Free Running)
Phase Shift Under 100% Unbalance Load
120 % + / - 0.5°
<2%
THD (Linear Load)
Overload
<110%
110 - 125%
Continuous
15 min
125 - 150%
>150%
10 min
60 sec
Efficiency (100% Load)
94.5%
Maximum Output Peak Current(A)
348
95%
432
520
693
STATIC SWITCH
Voltage Range
173 – 277 VAC (Line To Neutral)
Frequency Range
45 – 55Hz / 55 – 65Hz
Efficiency
Transfer Time
Overload
99.5%
Mains > Inverter
0 ms
0 ms
Inverter > Mains
100%
30 sec
300%
1 sec
Yes
Isolation With Output
OVERALL CHARACTERISTICS
92.5%
Overall Efficiency
93%
OPERATING ENVIRONMENT
Temperature
0 – 40°F ( 32 – 104°F )
0% - 90% ( Non–condensing )
Humidity
<1500m Above Sea Level
Altitude
Maximum Heat Dissipation(Kw)
4.6
5.4
6.5
8.7
Weight(Kg) (No Battery)
820
950
1180
1450
Dimension (mm) D x W x H
800 x 1100 x 1600
Audible Noise
< 65 dBA (@ 1 m)
Standards
Protections
En50091-1,-2
Yes
Short Circuit
Rectifier, Reserve, Bypass Nfb
Lightning
Mov
Emc Filter
Input & Output
Galvanic Isolation
Between Input & Output
Yes
Data Display By Lcd
Indications & Alarms
Yes
Fcc Class A
LED,LCD,BUZZER
Yes
Dry Contact
Yes
Battery Start
Yes
56
Online UPS
200KVA ~ 320KVA UPS 3-Phase Input / 3-Phase Output
MODELS
PRO533200S
PRO533240S
PRO533300S
PRO533320S
Capacity
200kVA
240kVA
300kVA
320kVA
INPUT
Input Voltage
380 / 400 / 415VAC 3 Phase 4 Wire
Input Range
307 – 520V
Input Frequency
50 / 60Hz +/- 7%
Input Power Factor
0.8
Normal Input Current(A)
350
420
525
560
Maximum Input Current(A)
437
525
656
700
788
840
295 – 410VDC / 285-415VDC
120
150
160
Power Walk In
0% - 100% : 20 sec
Efficiency
99%
Voltage Regulation
1%
525
Current Limit(A)
630
Ripple Voltage
0.5%
BATTERY
Type
Seal Lead Acid / NiCd
No. Of Cells
174 / 271
Voltage Range
Maximum Charge Current (Adc)
100
Battery Low Voltage
320VDC / 305VDC
Battery Low Stop
295VDC / 285VDC
Boost Charge
402VDC / 415VDC
Float Charge
390VDC / 410VDC
INVERTER
285 – 420VDC
Dc Input Range
Wave Form
Sinusoid
Output Voltage
380 / 400 / 415 VAC 3 Phase 4 Wire
Output Power Factor
0.8
+/-1%
Voltage Regulation 100% Unbalance Load
Frequency Lock Range
45 – 55Hz / 55 – 65Hz
50 / 60Hz + / - 0.1Hz
Output Frequency (Free Running)
Phase Shift Under 100% Unbalance Load
120 % + / - 0.5°
<5%
THD (Linear Load)
Overload
<110%
110 - 125%
Continuous
15 min
125 - 150%
>150%
10 min
60 sec
Efficiency (100% Load)
95%
Maximum Output Peak Current(A)
800
1000
1250
1300
STATIC SWITCH
Voltage Range
173 – 277 VAC (Line To Neutral)
Frequency Range
45 – 55Hz / 55 – 65Hz
Efficiency
99.5%
Mains > Inverter
Transfer Time
0 ms
0 ms
Inverter > Mains
Overload
100%
30 sec
300%
1 sec
Yes
Isolation With Output
OVERALL CHARACTERISTICS
93%
Overall Efficiency
OPERATING ENVIRONMENT
Temperature
0 – 40°F ( 32 – 104°F )
0% - 90% ( Non–condensing )
Humidity
<1500m Above Sea Level
Altitude
Maximum Heat Dissipation(Kw)
11.5
13
16.3
17.4
Weight(Kg) (No Battery)
2500
2700
3000
3100
Dimension (mm) D x W x H
800 x 2200 x 1600
Audible Noise
< 65 dBA (@ 1 m)
Standards
Protections
En50091-1,-2
Yes
Short Circuit
Rectifier, Reserve, Bypass Nfb
Lightning
Mov
Emc Filter
Input & Output
Galvanic Isolation
Between Input & Output
Yes
Data Display By Lcd
Indications & Alarms
Yes
Fcc Class A
LED,LCD,BUZZER
Yes
Dry Contact
Yes
Battery Start
Yes
*All specifications, designs and contents are subject to change without prior notice.
57
Line Interactive UPS
PRO SFC Series
Super Fast Charging
Line Interactive Series
650VA - 1200VA
PC
Printer
Work-Stations
PROLiNK SFC series is a single-phase input/ single-phase output
Line-Interactive UPS system with PROLiNK’s latest Super-Fast
Charging technology. This cutting-edge technology is able to
recharge the battery back to 90% of its capacity within 2-4 hours,
and is ideal for providing stable backup power to home/ small
office applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1 buck to
regulate output voltage. This prevents under voltage brownouts
and over voltage surges. The unit also comes with universal
sockets to provide better compatibility with a wider range of
devices.
• Built-in super fast charger, battery can be recharged to 90% of
its capacity within 2-4 hours
• Excellent microprocessor control guarantees high reliability
• Boost and buck AVR for voltage stabilization
• Auto restart while AC is recovering
• Simulated sine wave
• Off-mode charging
• Cold start function
• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection
Rear Panel
For 650VA to 1200VA model
1.
2.
3.
4.
5.
AC Input
Backup Output
Bypass Output (without battery back up)
USB Port (Only available in SFCU series)
RJ11
4
4
4
5
5
1
2
1
2
2
1
2
2
PRO700SFC/ SFCU
PRO850SFCU
2
3
PRO1200SFC/ SFCU
58
Line Interactive UPS
Full Specifications
MODELS
Capacity
VA
PRO700SFC/ SFCU
PRO850SFCU
PRO1200SFC/ SFCU
650
850
1200
INPUT
Nominal Voltage
220/ 230/ 240VAC
Voltage Range
140-300VAC
Nominal Frequency
50 or 60Hz (Auto Sensing)
OUTPUT
Output Voltage Regulation (Battery Mode)
±10%
Frequency
50Hz or 60Hz ±1Hz
Transfer Time (Typical)
Typical 2-6 ms
2 - 6ms, 10ms (max)
Waveform
Simulated Sinewave
BATTERY
Number of Battery
1 x 12V8.2AH
Recharge Time (Typical)
1 x 12V10AH
2 x 12V8.2AH
Back to 90% capacity in 2-4 hours
PROTECTION
Full Protection
Short Circuit, Overload, Discharge and Overcharge Protection
INDICATION
AC Mode – Green Lighting
Battery Mode – Yellow Lighting
LED Display
Charging Mode – Green Flashing every 2 seconds
Overload – Red Flashing every 0.5 seconds
Fault – Red Lighting
ALARM
Battery Mode – Sounding every 10 seconds
Low Battery – Sounding every second
Overload – Sounding every 0.5 seconds
Sounding
Battery Replacement Alarm – Sounding every 2 seconds
Fault – Continuously Sounding
PHYSICAL
287 x 100 x 142
Dimension (mm) D x W × H
Net Weight (kgs)
4.25
350 x 146 x 160
4.9
8
ENVIRONMENT
Humidity
0-90% relative Humidity, 0°C - +40°C
Noise Level
Less than 40dB
MANAGEMENT
USB/ RS-232
*All specifications, designs and contents are subject to change without prior notice.
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
59
Line Interactive UPS
PRO SFT Series
Super Fast Charging
Line Interactive With
Touch Screen Panel
650VA - 1200VA
PC
Printer
Work-Stations
The PRO SFT series is a single-phase input/ single-phase output
Line-Interactive UPS system with PROLiNK's latest Super-Fast
Charging technology. It allows for the battery to be recharged back
to 90% of its capacity within 2-4 hours, and is ideal for providing
stable backup power to home/ small office applications.
A wide input voltage range is supported due to the integrated
3-Step AVR which features 2 boosts and 1 buck to regulate output
voltage. This helps prevent under voltage brownouts and over
voltage surges. The unit also comes with a LCD user interface that
provides valuable information such as output voltage, input
voltage, load level, battery voltage and overload warning signals.
• Built-in super fast charger, battery can be recharged to 90% of
its capacity within 2-4 hours
• Excellent microprocessor control guarantees high reliability
• Boost and buck AVR for voltage stabilization
• Auto restart while AC is recovering
• Simulated sine wave
• Off-mode charging
• Cold start function
• LCD User Interface
Rear Panel
4
For 650VA to 1200VA model
1.
2.
3.
4.
5.
AC Input
Backup Output
Bypass Output (without battery back up)
USB Port (Only available in SFTU series)
RJ11
4
4
5
5
1
2
1
2
2
1
2
2
PRO700SFT/ SFTU
PRO850SFTU
2
3
PRO1200SFT/ SFTU
60
Line Interactive UPS
Full Specifications
MODELS
Capacity
VA
PRO700SFT/ SFTU
PRO850SFTU
PRO1200SFT/ SFTU
650
850
1200
INPUT
Nominal Voltage
230VAC
Voltage Range
140-300VAC
Nominal Frequency
50 or 60Hz (Auto Sensing)
OUTPUT
Output Voltage Regulation (Battery Mode)
+/ -10%
Frequency
50Hz or 60Hz +/ -1 Hz
Transfer Time (Typical)
Typical 2-6 ms
2 - 6ms, 10ms (max)
Simulated Sinewave
Waveform
BATTERY
Number of Battery
1 x 12V8.2AH
Recharge Time (Typical)
1 x 12V10AH
2 x 12V8.2AH
Back to 90% capacity in 2-4 hours
PROTECTION
Full Protection
Short Circuit, Overload, Discharge and Overcharge Protection
Display
LCD Display
Input voltage, output voltage, battery level, load level and UPS status
ALARM
Battery Mode – Sounding every 10 seconds
Low Battery – Sounding every second
Overload – Sounding every 0.5 seconds
Sounding
Battery Replacement Alarm – Sounding every 2 seconds
Fault – Continuously Sounding
PHYSICAL
300 x 101 x 142
Dimension (mm) D x W × H
Net Weight (kgs)
4.4
350 x 146 x 160
5
8
ENVIRONMENT
Humidity
0-90% relative Humidity, 0°C - 40°C (Non -condensing)
Noise Level
Less than 40dB
MANAGEMENT
USB/ RS-232
*All specifications, designs and contents are subject to change without prior notice.
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
61
Line Interactive UPS
PRO Series
Line Interactive Series
650VA – 1200VA
PC
Printer
Work-Stations
PRO Series is a single-phase input / single-phase output
line-interactive UPS system. It is able to provide clean
electrical power and is ideal for home / small office
applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1
buck to regulate output voltage. This prevents under voltage
brownouts and over voltage surges. The unit also comes
with universal sockets to provide better compatibility with a
wider range of devices.
• Built-in super smart charger, shorten 50% of charging time
• Excellent microprocessor control guarantees high reliability
• Boost and buck AVR for voltage stabilization
• Auto restart while AC is recovering
• Simulated sine wave
• Off-mode charging
• Cold start function
• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection
• Offering LED and LCD panels for selections
Rear Panel
For 650VA to 1200VA model
1.
2.
3.
4.
5.
AC Input
Backup Output
Bypass Output (without battery back up)
USB Port (Only available in VU and SVU series)
RJ11
4
4
4
5
1
1
2
1
2
5
3
2
1
2
2
2
PRO700V/ VU
PRO850VU
2
PRO850SU
2
3
PRO1200SV/ SVU
62
Line Interactive UPS
Full Specifications
MODELS
Capacity
VA
PRO700V/ VU
PRO850VU/ SU
PRO1200SV/ SVU
650
850
1200
INPUT
Nominal Voltage
220/ 230/ 240VAC
Voltage Range
140-300VAC
Nominal Frequency
50 or 60Hz (Auto Sensing)
OUTPUT
Output Voltage Regulation (Battery Mode)
±10%
Frequency
50Hz or 60Hz ±1Hz
Transfer Time (Typical)
Typical 2-6 ms
2 - 6ms, 10ms (max)
Simulated Sinewave
Waveform
BATTERY
Number of Battery
1 x 12V8.2AH
Recharge Time (Typical)
1 x 12V10AH
2 x 12V8.2AH
Back to 90% capacity in 4-6 hours
PROTECTION
Full Protection
Overload, discharge, and overcharge protection
INDICATION
AC Mode – Green Lighting
Battery Mode – Yellow Lighting
LED Display
Charging Mode – Green Flashing every 2 seconds
Overload – Red Flashing every 0.5 seconds
Fault – Red Lighting
ALARM
Battery Mode – Sounding every 10 seconds
Low Battery – Sounding every second
Overload – Sounding every 0.5 seconds
Sounding
Battery Replacement Alarm – Sounding every 2 seconds
Fault – Continuously Sounding
PHYSICAL
287 x 100 x 142
Dimension (mm) D x W × H
Net Weight (kgs)
4.25
350 x 146 x 160
4.9
8
ENVIRONMENT
Humidity
0-90% relative Humidity, 0°C - +40°C
Noise Level
Less than 40dB
MANAGEMENT
USB/ RS-232
*All specifications, designs and contents are subject to change without prior notice.
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
63
Line Interactive UPS
PRO-L Series
Line Interactive Series
600VA – 2000VA
PC
Printer
Work-Stations
PRO-L Series is a single-phase input / single-phase output
line-interactive UPS system that provides clean and reliable
back-up power for longer periods of time. It is able to provide
clean electrical power and is ideal for home / small office
applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1
buck to regulate output voltage. High voltage battery
chargers and battery extension assembly are made
available for longer runtime applications. The PRO-L Series
with capacities of up to 850VA also comes with universal
sockets to provide better compatibility with a wider range of
devices.
• Excellent microprocessor control guarantees high reliability
• Boost and buck AVR for voltage stabilization
• Adjustable battery charging current
• Auto restart while AC is recovering
• Off-mode charging
• Cold start function
• Simulated sine wave
Rear Panel
For 600VA to 2000VA model
1.
2.
3.
4.
5.
AC input
Input protection
Output outlet
Battery Connection
Fan
1
4
4
5
2
1
5
2
3
3
3
PRO700L
PRO1000L/
PRO2000L
64
Line Interactive UPS
Battery Pack
For 600VA to 2000VA model
Model
G6
Battery Type
G12
G18
G60
12V7AH/ 12V9AH/ 12V10AH
Battery Number
Dimension (DxWxH) mm
6 pcs
12 pcs
18 pcs
60 pcs
397 × 145 × 220
421 × 190 × 318
535 × 190 × 318
830 x 250 x 576
Full Specifications
MODELS
Capacity
VA
PRO700L
PRO1000L
PRO2000L
600
1000
2000
INPUT
Nominal Voltage
220/ 230/ 240VAC
Voltage Range
140 - 300VAC
Nominal Frequency
50Hz
OUTPUT
Output Voltage Regulation (Battery Mode)
±10%
Frequency
50 Hz ±1 Hz
Typical 4-8 ms
Transfer Time (Typical)
Simulated Sinewave
Waveform
BATTERY
Battery Voltage
Battery Capacity
Charging Current (max.)
12VDC
24VDC
Depending on the application
2.5A/ 6A/ 10A (adjustable)
5A/ 10A/ 15A/ 20A (adjustable)
PROTECTION
Full Protection
Overload, discharge, and overcharge protection
INDICATION
AC Mode – Green Lighting
LED Display
Battery Mode – Yellow Lighting
Fault – Red Lighting
ALARM
Low Battery – Sounding every second
Overload – Sounding every 0.5 seconds
Sounding
Battery Replacement Alarm – Sounding every 2 seconds
Fault – Continuously Sounding
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
358.5 x 96.8 x 146.5
5.8
395 x 145 x 220
9.0
13.55
ENVIRONMENT
Humidity
0-90% relative Humidity, 0°C - +40°C
Noise Level
*All specifications, designs and contents are subject to change without prior notice.
Less than 40dB
65
Line Interactive UPS
PRO Rack/ Tower Series
Line Interactive Series 800VA – 3000VA
PC
Printer
Work-Stations
19” Rack
Mount
PRO Rack / Tower series is a single-phase input / single-phase output UPS that employs a line-interactive technology.
This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a
floor-standing tower or in a mounting position using a 19-inch rack mount bracket. With its high density output power
factor of 0.8, this device is able to provide outstanding performance and efficiency for any home / small office
applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1
buck to regulate output voltage.
• Microprocessor-based line interactive design
• Pure sine wave output online mode and battery mode
• User-friendly and easy-shift LCD display
• Rack/Tower design
• Built-in boost and buck AVR
• Output Power Factor 0.8
• Hot swappable battery design
• Programmable power management outlets
• Emergency Power Off Function (EPO)
• Long-run models available
• Multiple communication available
• Option for SNMP communication.
Rear Panel
9
For 800VA to 3000VA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model)
11. Output terminal (IEC320-14)
12. Fan
13. External battery pack numbers detection port
8
6
7 13
1
5
12
4
3
4
3
2
PRT800S
9
8
6
7 13
12
1
5
10
2
PRT1100S/ PRT1100L/ PRT2000S/ PRT2000L
5
12
12
10
7
8
9
6
13
3
1
11
2
4
PRT3000S/ PRT3000L
66
Line Interactive UPS
Battery Pack
For 1.1kVA to 3kVA model
Model
G8R
Battery Type
G12R
G20R
12V7AH/ 12V9AH/ 12V10AH
Battery Number
Dimension (DxWxH) mm
8 pcs
12 pcs
20 pcs
480 x 438 x 88
600 x 438 x 88
580 x 438 x 133
Full Specifications
MODELS
PRT800S
PRT1100S/ L
PRT2000S/ L
PRT3000S/ L
Capacity
800 VA
1100 VA
2000 VA
3000 VA
INPUT
Nominal Voltage
208/ 220/ 230/ 240VAC
Voltage Range
162 ~ 290VAC
Nominal Frequency
50 or 60Hz
OUTPUT
Voltage Regulation (Batt. Mode)
±3%
Frequency
50Hz or 60Hz ±1Hz
Power Factor
0.8
3:1
Current Crest Ratio
Voltage Distortion
≦ 8% THD
Liner Load
≦ 15% THD
Non-Liner Load
Pure Sinewave
Waveform
EFFICIENCY
AC Mode
Up to 97%
BATTERY
Type
Standard Model
Capacity
Value regulated Lead Acid battery (Maintenance free batteries)
7AH
9AH
Recharge Time (Typical)
Back to 90% capacity in 4 hours
Charging Current
Type
Long-Run Model
1.0 A (max.)
Depending on the application
Capacity
Charging Current
INDICATORS
LCD Display
Depending on the application
N/A
4A / 8A
AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D × W × H
Net Weight (kgs)
Dimension (mm) D x W × H
Net Weight (kgs)
480 x 438 x 88
380 x 438 x 88
12.9
N/A
600 x 438 x 88
14.23
23.1
32.24
380 x 438 x 88
480 x 438 x 88
600 x 438 x 88
10.8
14
18
ENVIRONMENT
Operation Humidity
Ambient Temperature
Noise Level
0-90% (Non-condensing)
0°C - +40°C
≤ 45dB @ 1 Meter
MANAGEMENT
USB/ RS-232
*All specifications, designs and contents are subject to change without prior notice.
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
67
Line Interactive UPS
Outdoor Line Interactive UPS
Outdoor Line Interactive Series
PC
Work-Stations
CCTV
Traffic Light
Control System
The PROLiNK® PRO2000LD is a single-phase input/ single-phase output Outdoor UPS system. A wide operating
temperature range of -40°C to 80°C makes it ideal for outdoor usage. Designed to put up the best performance under the
harshest environment, the PRO2000LD is able to supply continuous power to critical loads during a blackout or power
outage.
Equipped with dry contacts, the PRO2000LD is able to program safety-oriented signals to meet the requirements of
different applications. As such, users are able to monitor UPS events that are most concerned to them. The PRO2000LD
comes in a capacity of 2000VA.
• Selectable transfer time for normal or generator mode
• User-adjustable charging current
• Adjustable input threshold voltage
• Provides programmable signals for dry contacts
• Battery compensation design
• RS-232, USB and SNMP intelligent port interface
Front Panel
For 2000VA model
1. AC input terminal block
2. AC input breaker
3. AC output terminal block
4. AC output breaker
5. Input contact
6. Dry contact
7. Internal fan
8. GND
9. Battery connector
10. Battery temperature sensor
11. External FAN connector
12. PTS control connector
13. Battery breaker
14. Battery voltage test points
15. Function keys
16. Liquid Crystal Display (LCD)
17. Indicator LEDs
18. USB connector
19. RS232 connector
20. Intelligent slot (optional)
14
19 18
20
1
2
4
3
16
17
5
15
6
7
13
12
11
10
8
9
PRO2000LD
68
Line Interactive UPS
Full Specifications
MODELS
PRO2000LD
2000 VA
Rated Power
INPUT
Nominal Voltage
230VAC
Acceptable Voltage Range
Frequency Range
170-300VAC
50 Hz/60 Hz (Auto sensing)
OUTPUT
Nominal Voltage
230VAC
Voltage Regulation (Batt. Mode)
230VAC ± 5%
Output Frequency
50Hz/60Hz ± 0.1%
THD (Batt. Mode)
<3% @ Full resistive load
Efficiency
Liner Mode
95%
AVR Mode
90%
Battery Mode
Transfer Time
Normal Mode (max.)
Generator Mode (max.)
Waveform
BATTERY
90%
12ms
25ms
Pure Sinewave
Nominal DC Voltage
Low DC Warning Voltage
Battery Type
Charging Current
INDICATORS
48VDC
46VDC ± 0.4VDC @ no load
AGM/Gel
2A/4A/6A/8A/10A (Adjustable)
Depending on the application
Bypass Mode
Green LED On
Battery Mode
Green LED Flashing
Green LED Off
No Output
Warning with Output
Yellow LED On
Fault without Output
Red LED On
MANAGEMENT
Communication
Dry Contact Rating
RS-232/USB and SNMP
3A @ 250Vac
PHYSICAL
Dimension (mm) D × W × H
400 x 240 x 133
Net Weight (kgs)
12.5
Type of Mechanical Protection
IP 20
ENVIRONMENT
Operation Humidity
Operating Temperature
Noise Level
5% to 95% Relative Humidity (Non-condensing)
-40°C to 80°C
< 48dB
COMPLIANCE
EMI Compliance
Class A FCC/CISPR [EN50091-2: 1995]
Surge Protection
IEEE/ANSI C.62.41 & 2KV, L-N
*All specifications, designs and contents are subject to change without prior notice.
69
Inverter UPS
IPS Series
Inverter Series
PROLiNK IPS Series is a compact home inverter system that delivers high efficiency conversion from DC to AC power.
This economically ideal system provides clean and stable power for home appliances and generator related devices. In
cases where the electrical utility is down, the home inverter system is able to draw DC current from the battery and supply
power to all the AC loads connected to it. Covering a wide selection of sizes, the IPS Series is available in capacities as
low as 600VA to as high as 5000VA.
• Selectable Voltage Range (Except for IPS600)
• Advanced Protection
• Auto restart while AC is recovering
• Comes with a built-in transformer (Only applies to IPS600, IPS850 & IPS1500)
• LCD and/or LED panel (Refer to the specifications)
4
Rear Panel
1
For IPS600
1.
2.
3.
4.
4
AC input
Output receptacles
Circuit breaker
External battery connector
3
2
IPS600
For IPS700 and IPS1201
1.
2.
3.
4.
5.
6.
Input voltage range selector
AC input
Input breaker
External battery connector
Charge current selector
Output receptacles
1 5
3
2
6
4
IPS700/ IPS1201
4
70
Inverter UPS
For IPS850 and IPS1500
1.
2.
3.
4.
5.
6.
Input voltage range selector
AC input
Input breaker
External battery connector
Charge current selector
Output receptacles
1 5
3
6
2
4
4
IPS850/ IPS1500
For IPS1200 and IPS2400
1.
2.
3.
4.
5.
6.
6
Operation mode selector
AC input
Input breaker
External battery connectors
Charge current selector
Output receptacles
1
2
5
3
4
IPS1200/ IP2400
For IPS3000 and IPS5000
1.
2.
3.
4.
Battery connector
Input protector
AC input
Inverter output
2
3
4
2
3
1
4
IPS3000
1
IPS3001
2
3
4
1
IPS5000
71
Inverter UPS
Full Specifications
Simulated Sinewave Inverter
MODELS
Capacity
VA
INPUT
Nominal Voltage
Voltage Range
IPS600
IPS850
IPS1200
IPS1500
IPS2400
600VA/ 360W
850VA/ 600W
1200VA
1500VA/ 1050W
2400VA
230 VAC
120 VAC or 230 VAC
220/ 230/ 240 VAC
120 VAC or 230 VAC
220/ 230/ 240 VAC
100 – 290 VAC
90-145 VAC/
90-145 VAC/
180-260 VAC
170-280 VAC
180-260 VAC
170-280 VAC
(For Personal Computers) (For Personal Computers) (For Personal Computers) (For Personal Computers)
50-160 VAC/
90-280 VAC
50-160 VAC/
90-280 VAC
100-300 VAC
(For Home Appliances)
100-300 VAC
(For Home Appliances)
(For Home Appliances)
(For Home Appliances)
Frequency Range
50/60 Hz (Auto Sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)
Transfer Time
200 ~ 230VAC ± 5%
120VAC ± 10% or
230VAC ± 10%
230VAC ± 10%
120VAC ± 10% or
230VAC ± 10%
230VAC ± 10%
13 ms (Typical)
20 ms (max)
10 ms (Typical)
20 ms (max)
20 ms (max)
10 ms (Typical)
20 ms (max)
>95%
Not Applicable
>95%
13.7 VDC ± 0.25 VDC
Not Applicable
27.4 VDC ± 2%
20.4 VDC ± 2%
27.4 VDC ± 0.5 VDC
Not Applicable
Not Applicable
Waveform (Batt. Mode)
Simulated Sinewave
>95% @ Rated R load
and battery full charged
Peak Efficiency
Not Applicable
BATTERY
Battery Voltage
12 VDC
24 VDC
Floating Charge Voltage
Low Battery Alarm Voltage
3.7 VDC ± 2%
10.8 VDC ± 2%
10.2 VDC ± 2%
Shutdown Voltage
10.0 VDC ± 2%
9.9 VDC ± 2%
Not Applicable
19.8 VDC ± 2%
Overcharge Protection
14.5 VDC ± 2%
15 VDC ± 2%
15 VDC
30 VDC ± 2%
30 VDC
13A
10A or 20A
10A or 20A (Selectable)
10A or 20A
10A or 20A (Selectable)
Maximum Charge Current
PROTECTION
Overload, deep
discharge, overcharge
and short circuit
protection
Full Protection
Overload and short circuit protection
INDICATORS
AC Mode, Battery Mode,
Load Level, Battery Level,
Input Voltage,
Output Voltage,
Overload, Fault and
Low Battery
LCD Display
LED Display
Not Applicable
Input Voltage,
Output Voltage,
Load level, Battery level
and Fault alarm
Not Applicable
Input Voltage,
Output Voltage,
Load level, Battery level
and Fault alarm
Line Mode
Fault
Green Lighting
Red Lighting
Not Applicable
Red Lighting
Green Lighting
Red Lighting
Not Applicable
Red Lighting
Battery Mode
Low Battery
Yellow Flashing
Not Applicable
Yellow Flashing
Yellow Flashing
Yellow Flashing
Not Applicable
Yellow Flashing
Yellow Flashing
Shutdown Mode
Charging Mode
Yellow Flashing
Yellow Flashing
Not Applicable
Overload
Green Flashing
Red Flashing
Not Applicable
Green Flashing
Red Flashing
Sounding every
2 seconds
Sounding every
second
Sounding every
2 seconds
ALARM
Low Battery
Sounding every second
Overload
Sounding every 0.5 second
Continuously sounding
Fault
Battery Replacement
Not Applicable
Sounding every
2 seconds
Not Applicable
Sounding every
2 seconds
Not Applicable
358.5 x 96.8 x 146.5
4.6
289 x 290 x 127
6.99
293 x 231.5 xx 82.5
2.35
289 x 290 x 127
10
293 x 231.5 xx 82.5
2.55
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
ENVIRONMENT
Humidity
0 to 90% Relative Humidity (Non-condensing)
Operating Temperature
Storage Temperature
0°C to 40°C
-15°C to 50°C
*All specifications, designs and contents are subject to change without prior notice.
-15°C to 70°C
Not Applicable
-15°C to 70°C
Not Applicable
72
Inverter UPS
Full Specifications
Pure Sinewave Inverter
MODELS
Capacity
VA
IPS700
IPS1201
IPS3000
IPS3001
IPS5000
700VA/ 500W
1200VA/ 840W
3000VA/ 2400W
3000VA/ 2400W
5000VA/ 4200W
INPUT
Nominal Voltage
Voltage Range
230 VAC
170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
180-270 VAC
(Normal Range)
100-270 VAC
(Wide Range)
170-280 VAC (Normal Range)
90-280 VAC (Wide Range)
Frequency Range
50/60 Hz (Auto Sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)
230VAC ± 5%
230VAC ± 10%
10 ms (For Personal Computers)
20 ms (For Home Appliances)
Transfer Time
Waveform (Batt. Mode)
Pure Sinewave
Peak Efficiency
90%
95%
90%
BATTERY
Battery Voltage
12 VDC
24 VDC
48 VDC
Floating Charge Voltage
Low Battery Alarm Voltage
13.5 VDC
11.5 VDC
21 VDC
53.6 VDC
42 VDC
Shutdown Voltage
10.5 VDC
20 VDC
40 VDC
15 VDC
30 VDC
58 VDC
10A or 15A (Selectable)
10A or 20A (Selectable)
20A or 35A (Selectable)
Overcharge Protection
Maximum Charge Current
27 VDC
27.4 VDC
PROTECTION
Full Protection
Not Applicable
Overload and short circuit protection
Protection against
misconnection
and improper usage
Not Applicable
INDICATORS
LCD Display
ALARM
Low Battery
Line Mode, Line mode with charging battery,
battery mode, off-mode charging, fault mode,
Low Battery, Overload, Power limitation,
Fan lock and Overcharge
AC Mode, Inverter Mode, Charger Mode
Load Level, Fault
Sounding every second
Sounding every 2 seconds
Sounding every 0.5 second
Continuously sounding
Overload
Fault
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
289 x 290 x 127
4.5
4.8
268 x 330 x 76
4.9
330 x 268 x 76
5
350 x 110 x 407
9
ENVIRONMENT
Humidity
0 to 90% Relative Humidity (Non-condensing)
Operating Temperature
Storage Temperature
5 to 95% (Non-condensing)
0°C to 50°C
0°C to 45°C
-15°C to 70°C
-15°C to 60°C
*All specifications, designs and contents are subject to change without prior notice.
73
Auto Voltage Regulator
PROLiNK PVR
PVR Series
PROLiNK PVR Series is designed to automatically maintain a
constant voltage level to protect sensitive electronics from
brownouts, under voltages and over voltages. The PROLiNK PVR
takes efficiency to a new level with its microprocessor controller
tailored to allow extremely fast response for detecting and
regulating voltage. Equipped with a time-delay function, the PVR
is able to protect connected devices from power-back surges.
This high performance AVR comes with the versatility to fit all
kinds of equipment with its wide input voltage range selection.
The PROLiNK PVR provides you with the optimum solution for
your everyday needs.
• Microprocessor control
• Accepts wide input voltage range
• Time delay function eliminates transient that can affect
connected equipment
• Provides stable output voltage
• Provides under-voltage, over-voltage, over-heat and over
current protection
• High voltage cut off
Full Specifications
MODELS
Capacity
VA
PVR500 D/M
PVR1000 D/M
PVR2000 D/M
PVR3000 D/M
500
1000
2000
3000
INPUT
Norminal Voltage
Voltage Range
220VAC
110VAC ~ 270VAC or 140VAC ~ 260VAC (selectable)
Nominal Frequency
50 or 60Hz (Auto Sensing)
OUTPUT
Voltage
220VAC
Output Voltage Regulation
± 10%
EFFICIENCY
Normal Mode
95%
AVR Mode
92%
PROTECTION
10 seconds
Delay Time
Full Protection
Over-voltage, under-Voltage, over-heat and over current Protection
INDICATION
LED Display
Normal indicator, AVR indicator, delay time setting and Fault indicator
Input and Output voltage
LCD/Meter Display
PHYSICAL
Dimension, D X W X H (mm)
Net Weight (kgs)
196.8 x 110 x 123.5
2.4
233.6 x 134 x 181
6.55
3.91
297.1 x 150 x 199
8.56
ENVIRONMENT
Operating Temperature
0°C - +40°C
0-90% relative Humidity (Non-condensing)
Humidity
D = LCD display, M = Analogue display
*All specifications, designs and contents are subject to change without prior notice.
74
DC UPS
PROLiNK DC UPS
PDC Series - DC UPS
PROLiNK PDC series is a compact DC UPS system that
converts AC to DC power. This device comes with a built-in
dynamic voltage regulator that ensures the voltage from
the power source is kept within acceptable limits. The PDC
Series is ideal for devices such as switches, hubs, routers
and modems. With the built-in DC start function, the PDC
UPS can be started up with the absence of AC power. The
PROLiNK PDC series is definitely your number one choice
for back-up power solution.
• Dual DC Outputs
• Microprocessor control guarantees high reliability
• Compact size for standing and mounting flexibility
• Supports solar powered devices and communication applications
• Auto restart while AC is recovering
• Off-mode charging
• Overload protection and short circuit protection
Full Specifications
MODELS
INPUT
Nominal Voltage
Voltage Range
Frenquency
PDC50
220VAC
160 - 280VAC
50 or 60Hz
OUTPUT
Nominal Voltage
Output Voltage Regulation
Transfer Time
12VDC
10V ~ 13.7V
0ms
EFFICIENCY
AC Mode
Battery Mode
>75% at Nominal Voltage (Battery Fully Charged)
>95% at Full Load
BATTERY
Battery Type
Charging Voltage
Charging Current
Typical Recharge Time
12V9AH x 1
13.7V ±0.25V
2.8A or 2.3A at Nominal Voltage without Load
Back to 90% capacity in 4-6 hours
INDICATION
AC Mode
Green Lighting
Battery Mode
Yellow Lighting
Low Battery
Yellow Flashing
Fault
PROTECTION
Full Protection
Red Lighting
Short Circuit and Overload Protection
PHYSICAL
Dimension (mm) D x W × H @ Vertically Stand
Net Weight (kgs)
228 x 82.5 x 207
3
ENVIRONMENT
Humidity
Temperature
0 ~ 90%
0°C ~ 40°C
75
DC UPS
PROLiNK DC BACK-UP UNIT
PBU Series
PROLiNK Back-Up (PBU) unit is a user-friendly lighting power supply
unit that is suitable for home/ outdoor settings. This portable-sized unit
is compact in size but it comes with a powerful 230VDC output that can
be used for powering up energy saving light bulbs of up to 11W. The unit
is designed with the flexibility to be powered by regular AC supply or via
the supplied battery. The PROLiNK PBU unit’s potential is best realized
for users that commonly experience power blackouts.
The unit is also brilliantly designed to allow a range of flexible display
methods: vertically or horizontally standing, wall-mounted or as a
portable display; as well as a choice to select between a B22 or E27 light
bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective
solution for your lighting requirements.
• DC-powered outlets for 11watts energy saving bulb
• 3 sets DC-powered outlets for energy saving light bulbs
• Off mode charging
• Overload protection in battery mode and short circuit protection
• LED indication
• 3-step charging design for extended battery life
Backup Time Table:
11W Safe Energy Light Bulb x 1 no
Up to 6 hours
11W Safe energy light bulb x 2 nos
Up to 3 hours
11W Safe energy light bulb x 3 nos
Up to 2 hours
11W Safe energy light bulb x 4 nos
Up to 1.5 hours
Full Specifications
MODELS
PBU5022 / PBU5027
Rated Power
50VA
INPUT
Voltage
Voltage Range
220VAC
100VAC – 300VAC
OUTPUT
Output Voltage (AC Mode)
2-pin Sockets
Output Voltage (Batt. Mode)
Waveform
BATTERY & CHARGER
Battery Type and Number
Battery Voltage
Typical Recharge Time
230VDC
160-230VDC ± 10%
DC Output
230 VAC
12V 7Ah x 1
12VDC
Back to 90% capacity in 6 hours
INDICATORS
AC Mode – Green Lighting
Battery Mode – Yellow Lighting
LED Display
Output Short-circuited – Red Lighting
Charging Mode – Green flashing every 2 seconds
Low Battery – Yellow flashing every second
Overload – Red Flashing every 0.5 seconds
Red LED staying on for one second and off for 4 seconds
PROTECTION
Full Protection
Overload Protection and short circuit protection
PHYSICAL
Dimension, D X W X H (mm)
Net Weight (kgs)
209 x 87 x 200
2.7
OPERATING ENVIRONMENT
Operating Temperature
Humidity
0°C to 40°C
0-90% relative Humidity (Non-condensing)
PBU5022 = for B22 light bulb terminal.
PBU5027 = for E27 light bulb terminal.
*All specifications, designs and contents are subject to change without prior notice.
B22 Connector
E27 Connector
76
Solar
PROLiNK Solar Inverter
Zonne Series
PROLiNK Zonne 450 unit is a compact and
user-friendly solar power unit that is suitable for use
in home like settings. The Zonne series is designed
with a built-in charger controller that facilitates
proper charging of the battery; enhancing the overall
lifespan of the battery.
Also, the PROLiNK Portable Solar unit comes with the
flexibility to be powered by regular AC supply, solar
PV modules or via the supplied battery. The Zonne
unit is capable of supporting up to one block of
100AH battery, giving users ample amount of power
supply to operate multiple home appliances.
• 450W Inverter
• PWM technology solar charger
• Off mode charging
• Overload protection and short circuit protection in battery mode
• Universal socket
Home Appliance
External Battery
Utility Supply
Solar Panel
Backup Time Table:
Battery Type
1 block x 12V40AH
Battery Type
1 block x 12V65AH
Effective Sunshine Duration
5 hours
Effective Sunshine Duration
5 hours
Application / Load
Battery back-up
2 x energy saving light bulb
8 hours per day
1 x energy saving light bulb
1 x Fan
2 x energy saving light bulb
1x Fan
6 hours per day
4 hours per day
Application / Load
Battery back-up
2 x energy saving light bulb
10 hours per day
1 x energy saving light bulb
1 x Fan
2 x energy saving light bulb
1x Fan
8 hours per day
All specifications, designs and contents are subjected to changes without prior notice.
The above Battery back-up calculation is based on estimated values and will be subject to change (Variables include; load consumption, sunshine duration and PV panel peak power supply).
6 hours per day
77
Solar
Full Specifications
MODELS
Zonne 450
Rated Power
AC INPUT
Voltage
450W
220/ 230/ 240VAC
Voltage Range
162 - 290VAC (UPS Mode)
90 or 280VAC (INV. Mode)
OUTPUT
Output Voltage
Voltage Regulation (Batt.Mode)
Waveform
BATTERY & CHARGER
Battery Voltage
Floating Voltage
Maximum Charge Current
230VAC
±10%
Simulated Sinewave
12VDC
13.4VDC ± 1.5%
10Amp
PROTECTION
Full Protection
Overload and Short Circuit Protection
INDICATORS
Line Mode
Battery Mode
Green Lighting
Yellow Lighting
Low Battery
Yellow Flashing every 2 seconds
Shutdown Mode
Yellow Flashing every 5 seconds
Charging Mode at Power On
Green Flashing every 2 seconds
Charging Mode at Power Off
Overload
Green Flashing every 5 seconds
Red Flashing for 0.5sec. every seconds
Overcharging
Fault
Red Flashing every 5 seconds
Red lighting
SOLAR CHARGER
Charging Current
10Amp
System Voltage
12VDC
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
*All specifications, designs and contents are subjected to changes without prior notice.
*Above mentioned Back-up timetable is for reference purpose only.
293 x 231.5 x 82.5
2.35
78
Solar
PROLiNK PORTABLE SOLAR
PPS Series
PROLiNK Portable Solar (PPS) unit is a compact and
user-friendly lighting solar power supply unit that is
suitable for use in home / outdoor settings. This
portable-sized unit is compact in size but it can be used
for powering up energy saving light bulbs of up to 11W. In
addition, there is also a 5VDC USB port for charging your
mobile devices and a 12VDC round pin connector for
equipment such as DC fans.
PROLiNK Portable Solar unit provides you the option of
doubling up your backup duration by adding another
block of 7AH battery on top of the existing supplied
battery. The PPS is the perfect device for users living in
rural locations where the power supply is often
inconsistent and unstable.
PPS70M
PPS70
PPS70
• DC-powered outlets for 11watts energy
saving bulb
• 3 x 5V USB charging ports for mobile phones
• PWM technology solar charger
• Off mode charging
• Overload and short circuit protection in
battery mode
• 12VDC round pin connector output for 12VDC
equipment
• Option for lamp holder with 2m cable
• Option for 24W Solar PV panel
3 Outlet For Energy Saving Bulb
12VDC Supply
Mobile Phone
Utility Supply
Solar
External Battery
PPS70M
• 11W DC UPS
• Built-in 3 watts LED.
• 12VDC-powered outlets for 11watts energy saving bulb
• 1 x 5V USB charging ports for mobile phones
• PWM technology solar charger
• Off mode charging
• Overload and short circuit protection
in battery mode
• Lamp holder with 5m cable
• 16W Solar PV panel
1 Outlet For 3watt LED Light Bulb
Solar
Mobile Phone
79
Solar
Full Specifications
MODELS
PPS70M
PPS70
PV INPUT
Maximum PV Array Open Circuit Voltage
Maximum Solar Charging Current
30VDC
1A
2A
AC INPUT
Voltage
230VAC
Frequency Range
Not Applicable
50 Hz or 60 Hz (auto sensing)
OUTPUT
Output Voltage (AC Mode)
2-pin Sockets
Output Voltage (Batt. Mode)
230VDC
Not Applicable
160-230VDC ± 10%
Waveform
12VDC
DC Output
DC Connector
USB Charger
12VDC 2A x 1 pc
Not Applicable
5VDC 1A x 3 pcs
5VDC 1A x 1 pc
Not Applicable
3W
LED LIGHT (Built-in)
Power
BATTERY & CHARGER
Battery Type and Number
Battery Voltage
Typical Recharge Time
12V 7Ah x 1 (Optional external battery)
Not Applicable
12VDC
Back to 90% capacity in 8 hours
Back to 90% capacity in 4-6 hours
PROTECTION
Full Protection
Overload Protection and short circuit protection
PHYSICAL
Dimension, D X W X H (mm)
Net Weight (kgs)
229 x 110 x 123.5
3.8
OPERATING ENVIRONMENT
Operating Temperature
0°C to 40°C
0-90% relative Humidity (Non-condensing)
Humidity
*All specifications, designs and contents are subject to change without prior notice.
80
Solar
PROLiNK Solar System
PCC Series
PCC Series is a Solar Installation System that combines the
benefits of both the Maximum Power Point Tracking (MPPT)
technology and DSP controller system. The MPPT enhances the
PCC Series by transferring the most power from its PV solar
modules and the DSP controller system provides a high level of
computational performance for real-time signal processing in the
solar power inverters. This allows your solar panels to operate at
their optimum power output voltage, thereby increasing the level of
efficiency to 97.7% and at the same time lowering power loss.
Users can start generating green energy for their home applications
by integrating the PCC Series with solar panels, inverter and
external battery packs. Batteries are compatible with up to 4 types;
sealed lead acid, vented, gel and NiCad.
• Intelligent Maximum Power Point Tracking technology
• Built-in DSP controller with high performance
• Automatic battery voltage detection
• Multi-functional LCD
• Reverse polarity protection for solar panel and battery
• Overcharge and overload protection
• Suitable for battery types such as sealed lead acid, vented Gel and NiCd
• Standard RJ45 port or optional RS-485 communication port for remote monitoring
PCC300
Solar Panel
Inverter
External Battery Packs
Home Appliances
*All specifications, designs and contents are subject to change without prior notice.
81
Solar
Full Specifications
MODELS
INPUT
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
PCC300
PCC600
15 ~ 33V @ 12V
30 ~ 66V @ 24V
50V
75V
Maximum Array
PCC3000
60 VDC ~ 115 VDC
145VDC
Maximum PV Array Power
Maximum Current
800W
18A
1600W
3200W
50A
OUTPUT
Nominal Battery Voltage
12V
24V
Connected Battery Type
Maximum Charging Current
12V
24V
48V
Sealed Lead Acid, Vented, Gel, MiCd Battery
25A
60A
Ripple Voltage
<±1V
Maximum Efficiency
Stanby Power Consumption
98%
98%
1W
2W
Charging Method
Three Stages: Bulk, Absorption & Floating
PROTECTIONS
Overload Protection
>110%: Audiable Alarm
INDICATION
LCD Panel
Yes
Yes
Yes
Overcharge Protection
Polarity Reversal Protection @ Solar Cell & Battery
LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions
Three indicators: Solar, Charging & Load Status
LED Display
Three indiators: Solar, Battery &
Wiring Fault
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
Connector
135 x 170 x 57.5
0.92
220 x 170 x 57.5
1.85
Input or Output Terminal Block
315 x 165 x 128
4.5
IP43
IP31
0~90% Relative Humidity (Non-condensing)
5~95% Relative Humidity
(Non-condensing)
Type of Mechanical Protection
ENVIRONMENT
Humidity
Operating Temperature
-20°C to 55°C
Storage Temperature
-40°C to 75°C
Altitude
0 ~ 3000m
*All specifications, designs and contents are subject to change without prior notice.
82
Solar
PROLiNK Solar System
PSI Hybrid
HYBRID Series
PSI Hybrid Series is a hybrid inverter that combines the solar power system, AC
utility and battery power source to supply continuous power to your home / office
applications. This device is most suitable for rural areas where electrical supply is
unstable and inconsistent. The PSI Hybrid series comes with a grid-tie operation
mode where surplus electricity can be fed back to the main grid, making it an
economic and cost-effective power option. If gaining access on the grid is not
possible, the PSI Hybrid Series also comes with an off-grid operation mode where
power can be stored directly to the back-up battery; making the Hybrid series one
of most versatile solar inverters in the market.
• Works as an On-grid inverter during the day
• Works as an Off-grid inverter during the night or rainy conditions
• Pure sine wave output
• Multiple operations: Grid tie, Off grid, and grid-tie with backup
• Built-in MPPT solar charger
• LCD display panel for comprehensive information
Full Specifications
MODELS
HYBRID 3K
HYBRID PRO 3K
Single Phase
Phase
PV INPUT
Maximum DC Voltage
MPP Voltage Range
DC Nominal Voltage
Start-up Voltage / Initial Feeding Voltage
Maximum Input Current
HYBRID 10K
Three Phase
500VDC
900VDC
250 VDC ~ 450VDC
400 ~ 800VDC
360VDC
720VDC
116VDC / 150VDC
320VDC / 350VDC
13A
18A
18.6A x 2
GRID/ UTILITY INPUT (AC)
Phase
Single Phase
Nominal AC Voltage/ Range
Acceptable Voltage Range
Maximum Input Current
Three Phase
208/ 220/ 230/ 240VAC
400VAC
170 ~ 280VAC
170 - 280VAC
30A
25A
GRID OUTPUT (AC)
Nominal AC Voltage/ Range
220VAC / 184~265VAC
AC Grid Frequency Range
Nominal Output Current
Power Factor
BATTERY MODE OUTPUT (AC)
Output Voltage
13A
14.5A
>0.99
-
202/ 208/ 220/ 230/ 240VAC
400VAC
50Hz / 60Hz (auto sensing)
Output Frequency
Pure Sinewave
Output Waveform
Efficiency (DC to AC)
400VAC / 320~460VAC
47.5 ~ 50.2Hz
93%
96%
BATTERY & CHARGE
Nominal DC Voltage
Maximum Charging Current
25A
200A
PHYSICAL
Dimension (mm) D x W × H
107 x 438 x 480
622 x 500 x 167.5
15.5
45
Net Weight (kgs)
48VDC
INTERFACE
Communication Port
Intelligent Slot
RS-232 / USB
Optional SNMP, Modbus and AS-400 cards available
ENVIRONMENT
Operation Humidity
Operating Temperature
0~90% (Non-condensing)
0°C~40°C
Altitude
-10°C to 55°C
0 ~ 1000m
** Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details.
*All specifications, designs and contents are subject to change without prior notice.
83
Solar
PROLiNK Solar System
PSI On-Grid
AMNETZ Series
PSI On-Grid Series is a grid-connected photovoltaic power system that is
designed to operate at its optimum power output voltage even under
unfavourable weather conditions. This device uses high quality Amnetz
PV inverters to convert DC to AC power at a maximum conversion
efficiency of up to 96%. On top of that, this user-friendly device is bundled
with a monitoring software kit that allows users to observe from a
graphical overview of the module voltage/current and temperature.
• 1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter
• Advanced DSP control technology delivers accurate data
• Smart MPPT technology enhances overall efficiency
• Modular design for easy maintenance
• Industrial-grade components used for robust operation
• Up to 15 years of data logging
• Ingress Protection rated 65 (good for any type of environmental conditions)
• Comprehensive LCD monitor for easy-reading
• Free monitoring software
Full Specifications
MODELS
Phase
AMNETZ 1500
INPUT (DC)
Maximum DC Voltage
MPP Voltage Range
450VDC
500VDC
150 ~ 400VDC
200 ~ 450VDC
Nominal DC Voltage
Start-up Voltage/ Initial Feeding Voltage
Maximum Input Current/ Per String
OUTPUT (AC)
Nominal AC Voltage
AMNETZ 2000
AMNETZ 3000
1 Phase-In 1 Phase-Out
AMNETZ 10K**
3 Phase-In 3 Phase-Out
500VDC
500VDC
900VDC
320 ~ 800VDC
150 ~ 500VDC
360VDC
370VDC
600VDC
120/ 150VDC
125/ 150VDC
250/ 250VDC
11A
230VAC
230VAC
13A
2 x 15A
2 x 17A / 17A
230VAC
230VAC
3/ N/ PE, 230/ 400VAC
AC Voltage Range
184 - 264VAC*
AC Grid Frequency
50Hz / 60Hz
Nominal Output Current
AMNETZ 5000
6.6A
8.7A
Power Factor
-20% ~ +15%*
20A
13A
14.5A
>0.99
EFFICIENCY
Maximum Efficiency
96.0%
97%
98.0%
PROTECTION
DC Reverse-Polarity Protection
Yes
Ground Fault Monitoring
Grid Monitoring
Yes
Yes
AC Short Circuit Protection
Yes
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
136.5 x 268.5 x 410
160 x 270 x 450
182 x 308 x 515
171.2 x 503.5 x 653.3
11.5
15
20
40
INTERFACE
Intelligent Slot
ENVIRONMENT
Humidity
USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards
0 ~ 100% Relative Humidity (nNon-condensing)
Operating Temperature
Altitude
-25 ~ 60°C
-25 ~ 60°C
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)
COMPLIANCE
Standard
CE, VDE-AR-N 4105, VDE-0126-1-1, IEC62109
*All specifications, designs and contents are subject to change without prior notice.
**Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details.
84
Solar
PROLiNK Solar System
PSI Off-Grid
HAUS Series
The PSI HAUS Series is a wall-mounted off grid PV inverter that
employs a PWM technology. It is best used in remote locations
without utility services. The device is able to supply generous
amount of electrical power to the load via PV modules, battery
sources and AC powered sources. The HAUS Series is able to fully
utilize the energy from the sun to convert stable electrical power to
any home / commercial applications. In the event where it is
inapplicable to draw power from PV modules and battery sources,
an AC power source can still be supplied by a generator to get you
through a rainy day.
• Pure sine wave inverter
• Selectable input voltage range
• Selectable charging current
• Utility or Solar input priority configuration via LCD setting
• Generator compatible
• Auto restart while AC is recovering
• Overload and short circuit protection
• Cold start function
• Optional N+1 parallel redundancy
Full Specifications
MODELS
HAUS 1000
HAUS 2000
HAUS 3000
HAUS 4000
HAUS 5000
Rated Power
1kVA / 800W
2kVA / 1.6kW
3kVA / 2.4kW
4kVA / 3.2kW
5kVA / 4kW
INPUT
Voltage
230VAC
170 - 280VAC (For Personal Computers)
90 - 280VAC (For Home Applicances)
Selectable Voltage Range
Frequency Range
50 Hz / 60 Hz (Auto Sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)
Surge Power
230VAC ± 5 %
2000VA
4000VA
6000VA
Efficiency (Peak)
8000VA
10000VA
93%
Transfer Time
10 ms (For Personal Computers)
Waveform
Pure sine wave
BATTERY
Battery Voltage
Floating Charge Voltage
Overcharge Protection
Maximum Charge Current
12VDC
24VDC
48VDC
13.5VDC
15VDC
10A or 20A
27VDC
30VDC
20A or 30A
54VDC
60VDC
20A or 30A
30VDC
60VDC
SOLAR CHARGER (OPTION)
50A
Charging Current
Maximum PV Array Open Circuit Voltage
90VDC
PHYSICAL
Dimension, D X W X H (mm)
Net Weight (kgs)
95 x 240 x 316
5.0
100 x 272 x 355
6.4
6.9
120 x 295 x 468
9.8
OPERATING ENVIRONMENT
Humidity
5% to 95% Relative Humidity (Non-condensing)
Operating Temperature
Storage Temperature
*All specifications, designs and contents are subject to change without prior notice.
0°C to 55°C
-15°C to 60°C
85
Solar
PROLiNK Solar System
PSI Off-Grid
HAUS MPPT Series
HAUS
1KM/ 1KMHDC/ 2KM/ 3KM/ 3KMHDC
HAUS
4KMHDC/ 5KMHDC
HAUS PLUS
2KM/ 2KMHDC/
3KM/ 3KMHDC
The PSI HAUS MPPT Series is a wall-mounted off grid PV inverter that employs a MPPT technology. It is best used in
remote locations without utility services. The device is able to supply generous amount of electrical power to the load via
PV modules, battery sources and AC powered sources. The HAUS MPPT Series is able to fully utilize the energy from the
sun to convert stable electrical power to any home / commercial applications. In the event where it is in applicable to
draw power from PV modules and battery sources, an AC power source can still be supplied by a generator to get you
through a rainy day.
• Pure sine wave inverter
• Built-in MPPT solar charge controller
• Selectable input voltage range for home appliances and personal computers
• Selectable charging current based on applications
• Configurable AC/Solar input priority via LCD setting
• Compatible to mains voltage or generator power
• Auto restart while AC is recovering
• Overload and short circuit protection
• Smart battery charger design for optimized battery performance
• Cold start function
• Parallel operation with up to 6 units only available for 4KVA/5KVA
• Optional Remote Control Panel available
86
Solar
Full Specifications
MODELS
Capacity
HAUS
1KM
HAUS
1KMHDC
HAUS
2KM
HAUS
3KM
HAUS
3KMHDC
HAUS
4KMHDC
HAUS
5KMHDC
1000VA/ 800W 1000VA/ 800W 2000VA/ 1600W 3000VA/ 2400W 3000VA/ 2400W 4000VA/ 3200W 5000VA/ 4000W
INPUT
Voltage
230 VAC
170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
Selectable Voltage Range
Frequency Range
50/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)
230VAC ± 5%
Surge Power
2000 VA
Efficiency (Peak)
4000 VA
6000 VA
90% - 93%
Transfer Time
8000 VA
10000 VA
93%
10 ms (For Personal Computers); 20 ms (For Home Appliances)
Waveform
Pure sine wave
BATTERY & AC CHARGER
Battery Voltage
24 VDC
48 VDC
24 VDC
48 VDC
Floating Charge Voltage
27 VDC
54 VDC
27 VDC
54 VDC
Overcharge Protection
31 VDC
62 VDC
31 VDC
600 W
900 W
62 VDC
60 VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Power
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum Solar Charge Current
Maximum AC Charge Current
Maximum Charge Current
30VDC ~ 66VDC 60VDC ~ 88VDC
600 W
900 W
3000 W
30VDC ~ 66VDC
60VDC ~ 88VDC
60VDC ~115VDC
75 VDC
102 VDC
75 VDC
102 VDC
145 VDC
25A
20A
18A
15A
25A
30A
18A
15A
60A
60A
18A
30A
18A
120A
25A
AC charger and solar charger can’t work at the same time.
Maximum Efficiency
98%
Standby Power Consumption
2W
120A
PHYSICAL
100 x 272 x 355
Dimension, D x W x H (mm)
Net Weight (kgs)
6.8
120 x 295 x 468
7.0
7.4
11
ENVIRONMENT
Humidity
5% to 95% Relative Humidity(Non-condensing)
Operating Temperature
0°C - 55°C
Storage Temperature
MODELS
Inverter Power
Pmax. Generated From Solar Charger
Best Panel Configuration
-15°C - 60°C
HAUS
1KM
HAUS
1KMHDC
HAUS
2KM
HAUS
3KM
HAUS
3KMHDC
800W
1000W
1600W
2400W
2400W
25Amp, 600W
20Amp, 900W
25Amp, 600W
25Amp, 600W
20Amp, 900W
HAUS
4KMHDC
HAUS
5KMHDC
3200W
4000W
60Amp, 3000W 60Amp, 3000W
500Wp
1000Wp
500Wp
500Wp
1500Wp
3000Wp
3000Wp
(250Wp x 2pcs) (250Wp x 4pcs) (250Wp x 2pcs) (250Wp x 2pcs) (250Wp x 6pcs) (250Wp x 12pcs) (250Wp x 12pcs)
87
Solar
MODELS
HAUS PLUS
2KM
HAUS PLUS
2KMHDC
HAUS PLUS
3KM
HAUS PLUS
3KMHDC
Capacity
2000VA/ 800W
2000VA/ 1000W
2000VA/ 1600W
3000VA/ 2400W
INPUT
Voltage
Selectable Voltage Range
120 VAC or 230 VAC
230 VAC
95-140 or 170-280 VAC (For Personal Computers)
65-140 or 90-280 VAC (For Home Appliances)
170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
Frequency Range
50/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)
110/120 VAC ± 5% (User Selectable) or 230VAC ± 5%
230VAC ± 5%
4000 VA
6000 VA
Surge Power
Efficiency (Peak)
90% - 93%
Transfer Time
10 ms (For Personal Computers); 20 ms (For Home Appliances)
Waveform
Pure sine wave
BATTERY & AC CHARGER
Battery Voltage
24 VDC
48 VDC
24 VDC
48 VDC
Floating Charge Voltage
27 VDC
54 VDC
27 VDC
54 VDC
Overcharge Protection
31 VDC
62 VDC
31 VDC
62 VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Power
MPPT Range @ Operating Voltage
1500 W
3000 W
1500 W
3000 W
30~115 VDC or 60~115 VDC
60~115 VDC
30~115 VDC or 60~115 VDC
60~115VDC
Maximum PV Array Open Circuit Voltage
145 VDC
Maximum Solar Charge Current
Maximum AC Charge Current
60A
20A or 20A / 30A
10A or 10A / 15A
20A 30A
Maximum Efficiency
98%
Standby Power Consumption
2W
10A / 15A
PHYSICAL
140 x 295 x 479
Dimension, D x W x H (mm)
Net Weight (kgs)
11.5
ENVIRONMENT
Humidity
5% to 95% Relative Humidity(Non-condensing)
Operating Temperature
0°C - 55°C
Storage Temperature
-15°C - 60°C
HAUS PLUS
2KM
MODELS
Inverter Power
HAUS PLUS
2KMHDC
HAUS PLUS
3KM
60Amp, 3000W
1500Wp (250Wp x 6pcs)
60Amp, 1500W
1600W
Pmax. Generated From Solar Charger
Best Panel Configuration
60Amp, 1500W
There are charging current selection only available for 230VAC system.
*All specifications, designs and contents are subject to change without prior notice.
HAUS PLUS
3KMHDC
1600W
60Amp, 3000W
3000Wp (250Wp x 12pcs)
88
Software & Accessories
PROLiNK Online UPS Accessories
External Battery Charger (PEC)
PROLiNK External Charger (PEC) is an additional external smart
charger for PROLiNK Online UPS system. It designed with
isolation structure and operated in parallel with several units for
charging capability expandable.
• Input PFC control
• Back feed protection
• Three-stage smart charging
• Short circuit and over voltage protection
• Maximum current restriction
• Redundancy operation
With PROLiNK External Battery Cabinet
UPS
Expandable
Charger units
With External Battery Bank
Expandable PROLiNK
battery cabinets
UPS
Expandable
Charger units
Expandable
battery units
Full Specifications
MODELS
PEC20-24
PEC15-36
PEC15-48
INPUT
Nominal Voltage
PEC12-72
PEC10-96
PEC24-240
230VAC
170~280VAC
Voltage Range
Nominal Frequency
110~300VAC
50/60Hz
8A
Input Current (max) @ full load
60A
OUTPUT
Nominal Voltage
Output Current (max)
Floating Charging Voltage
24VDC
36VDC
20A
48VDC
72VDC
96VDC
12A
10A
24A
82.2VDC
109.6VDC
273.6VDC
15A
27.3VADC
41.1VDC
54.8VDC
240VDC
EFFICIENCY
AC Mode
Up to 85%
PROTECTION
Full Protection
Over-voltage, Thermal control, Over current, Short circuit, Reversal polarity
INDICATION
Charger ON – Green LED
LED Display
Boost Charging Status – Yellow LED
Floating Charging Status – Green LED
N/A
Low Charging Voltage – Red LED
PHYSICAL
Dimension (mm) D x W × H
Net Weight (kgs)
300 x 177 x 90
570 x 250 x 215
3.1
14
ENVIRONMENT
Relative Humidity
Operation Temperature
Noise Level
IP Class
<95% (Non-condensing)
0 ~ 40°C
<50dB
IP20
All specifications, designs and contents are subjected to changes without prior notice.
89
Software & Accessories
PROLiNK Online UPS Accessories
Automatic Transfer Switch
PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the
connected load. In the event where the primary power source fails, the ATS automatically transfers the backup
connection to the secondary power source without any interruption, providing seamless electrical power and the highest
protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection back to the
primary power source once it has detected restored power.
• 16A maximum input current
• Powered by two separate independent power sources
• Dual power supply for redundancy
• Provides seamless power switch for IT equipment
• Preferred source selection on front panel
• 19” rack-mount design (1U)
• Built-in USB and RS-232 interface
Full Specifications
MODELS
ATS16-R
Current Rating
INPUT
Input Voltage
Acceptable Input Voltage
Input Frequency
16A
230VAC
207 ~ 253VAC
50Hz/ 60Hz
OUTPUT
Output Voltage
Maximum Output Current
230VAC
10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets
CONNECTION
2xIEC-C20 Inlets
Input
Output
8xIEC-C13; 1xIEC-C19
Communication
Transfer Time
PHYSICAL
Dimension (mm) D x W x H
Net Weight (kgs)
USB/ RS-232
9 ~ 12ms (Typical)
310 x 430 x 44
3.65
ENVIRONMENT
Operating Temperature
*All specifications, designs and contents are subject to change without prior notice.
20 ~ 95% Relative Humidity @ -5°C ~ 45°C (Non-condensing)
90
Software & Accessories
PROLiNK Online UPS Accessories
PDU & Maintenance
Bypass Switch
The PDU & Maintenance Bypass Switch is an external power
distribution unit used in conjunction with UPS systems or
large-scale voltage regulators. This device enables the UPS to be
isolated for scheduled maintenance or replacement without
interrupting the power to the load. Designed with a
master-controller concept, the PROLiNK PDU is able to handle
both the maintenance bypass function and power saving function
effectively.
• 16A for 208/220/230/240 VAC
• Provides continuous power to connecting equipment during UPS maintenance
• Easy operation with simple rotary switch and indicators
• Master-slave function for energy saving
• Multiple sockets to support more devices
• Choose between a rack or tower design to fit into any working environment
• Simple installation with plug-and-play socket type
• Suitable for all UPSs up to 3kVA
IEC
UK
Schuko NEMA
Full Specifications
MODELS
MBS16-R (I/U/S/N) (*)
MBS16-T (I/U/S/N) (*)
Current Rating
16A
Voltage Rating
208/ 220/ 230/ 240/VAC
Master/ Slave Function
Yes. When power consumption in Master Outlet is lower
than 20W (±5W), it will shut off the power for slave outlets.
NA
CONNECTION
1 x IEC (16A) Connector & 1 x Customized Plug Cable
AC Power
Input
UPS Input
UPS Output
IEC
Output
1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)
5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers) 8 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)
Schuko
4 x Schuko 16A Sockets
4 x UK 13A Sockets
UK
5 x NEMA 20A Sockets
6 x NEMA 20A Sockets
IEC
80 x 438 x 50
180 x 160 x 50
Schuko
UK
80 x 438 x 60
180 x 200 x 50
NEMA
80 x 438 x 50
180 x 160 x 50
1.50
1.30
NEMA
PHYSICAL
Dimension (mm)
DxWxH
Net Weight (kgs)
ENVIRONMENT
Operating Temperature
I = IEC, U = UK, S = EU, N = Nema
*All specifications, designs and contents are subject to change without prior notice.
20 ~ 95% Relative Humidity @ -0°C ~ 40°C (Non-condensing)
91
Software & Accessories
PROLiNK Online UPS Accessories
SNMP Card
Integrated with our latest ViewPower software, the SNMP manager operates as an enhanced
communication solution for your UPS system. It allows you to remotely manage and monitor
your UPS system via internet connectivity. Once connected to the internet, the ViewPower
software provides you access to remotely program or even shut down your UPS system.
• Allows control and monitoring of multiple UPSs through RJ-45 network connection
• Real-time dynamic graphs reflecting UPS data (Voltage, frequency, load level and
battery level)
• Warning notifications via audible alarm, broadcast, mobile messenger,
e-mail and SNMP traps
• Historical data logging
• One click easy firmware upgrade
• Password security protection and remote access management
• Supports optional environmental monitoring detector for temperature, humidity and smoke
Modbus Card
The ModBus Card provides UPS and PV inverter systems with the functionality to
communicate with PCs through the ModBus Protocol.
• Adopts ModBus RTU Protocol
• Comes with functions that includes read Holding Registers and write Registers
• RS232 and RS485 interface
AS-400 Card
The AS-400 communication card is designed with a high quality contact closure board that
accurately converts UPS signals into dry contacts for users to monitor UPS events that are
most concerned to them. By setting the jumper, the AS-400 communication card allows you to
select various status indicators such as; UPS alarm, UPS failure, Bypass, Low Battery etc.
• Capable of selecting the status of the dry-contact signal by setting the jumper to meet
different application requirements
• Suitable applications include; IBM Server, Personal PC & Workstations equipments,
Auto-controlled industrial equipment & communication applications
Rack Mount Slider
The PROLiNK Rack-mount slider kit offers you the best solution to install a PROLiNK UPS
system into a 19” server rack enclosure. This kit comes with a pair of heavy duty sliders that
are attached with quality assured ball bearings to ensure that your server can slide effortlessly
into and out of the rack. Furthermore, the PROLiNK Rack-mount slider kit includes a superior
quality front and rear mounting brackets to withstand the weight of your UPS.
• Simple and easy installation
• Suitable for PROLiNK Rack Mount Online UPS system
• Slider length available in 700mm and 1100mm to suit different types of cabinet
92
Software & Accessories
PROLiNK Online UPS Software
Viewpower – UPS Management Software
ViewPower is an advanced UPS management software that is designed for users to remotely monitor and manage
multiple UPS units in a networked environment, either by LAN or INTERNET. The ViewPower software is able to protect
your important data by executing a safety OS shutdown during power failure. Better yet, this software gives users the
ability to store programming data and also scheduled a UPS shutdown when necessary.
• Allows control and monitoring of multiple UPSs via
LAN and INTERNET
• User-friendly power analysis graphs
• Real-time dynamic graphs of UPS data
• Safety OS shutdown to prevent data losses during
power failure
• Warning notifications via audible alarm, broadcast,
mobile messenger, and e-mail
• Scheduled UPS on/off, battery test, programmable
outlet control, and audible alarm control
• Password security protection and remote access
management
• Supports multiple OS and local languages
Solar Power Management Software
SolarPower Pro is a solar inverter monitoring software that is capable of monitoring up to 247 devices via a modbus
interface. When connected to a networking environment, users are able to monitor the Solar inverter via a web browser. The
SolarPower Pro comes with a variety of features including; data logging, ability to generate statistical data, alarm
notifications, prompting fault messages and parameter control for devices.
• Allows control and monitoring of multiple devices
via LAN and INTERNET
• Automatic and real-time data acquisition
• Secure data logging
• Graphic display of device data for quick and easy
reading
• Warning notifications or fault alarms via audible
alarm, pop-up screen, broadcast, mobile messenger,
tray message and e-mail
• Easy diagnosis from event statistics and amount
calculation for energy saving
• Maximum data log up to 10 billion records
• Supports online upgrade and manually upgrade
• Supports multiple languages: English, Chinese,
French, German, Spanish, Russian, Portuguese,
Ukrainian, Italian, Polish
93
Appendix
PROLiNK UPS Battery Backup Configuration List
1. Professional Series (1P/1P) - Tower
BACK UP
TIME
POWER
RATING
BATTERY
GROUP
DC BUS
(VDC)
15 MINUTES
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
C6*1
12V65AH*6
PEC20-24*1
C8*1
12V65AH*8
PEC20-24*1
C12*1
12V65AH*12
PEC15-48*1
C20*1
12V65AH*18
PEC12-72*1
C16*1
12V65AH*16
PEC15-48*1
C24*1
12V65AH*24
PEC12-72*1
C32*1
12V65AH*32
PEC10-96*2
C20*2
12V65AH*40
PEC10-96*3
PRO901L
2/24VDC
C1*1
12V26AH*2
C1*1
12V17AH*4
C2*1
12V65AH*2
C3*1
12V100AH*2
PRO902L
4/48VDC
C2*1
12V26AH*4
C2*1
12V17AH*8
C4*1
12V65AH*4
C4*1
12V100AH*4
PRO903L
6/72VDC
C3*1
12V26AH*6
C3*1
12V17AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
PRO906L
8/96VDC
C4*1
12V17AH*16
C8*1
12V26AH*16
C8*1
12V100AH*8
C24*1
12V65AH*24
PC96*1
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
2. Master Series (1P/1P) - Tower
BACK UP
DC BUS
TIME
(VDC)
POWER
BATTERY
RATING
GROUP
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO801L
3/36VDC
C1*1
12V17AH*3
C1*1
12V26AH*3
C3*1
12V26AH*6
C3*1
12V65AH*3
C6*1
12V65AH*6
PEC15-36*1
C6*1
12V100AH*6
PEC15-36*1
PRO8015L
3/36VDC
C1*1
12V26AH*3
C2*1
12V17AH*6
C3*1
12V65AH*3
C3*1
12V100AH*3
C6*1
12V100AH*6
PEC15-36*1
C12*1
12V65AH*12
PEC15-36*2
PRO802L
6/72VDC
C2*1
12V17AH*6
C3*1
12V26AH*6
C6*1
12V26AH*12
C6*1
12V65AH*6
C20*1
12V26AH*36
PEC12-72*1
C12*1
12V100AH*12
PEC12-72*1
PRO803L
6/72VDC
C3*1
12V26AH*6
C3*1
12V17AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
PEC12-72*1
C12*1
12V100AH*12
PEC12-72*1
C20*1
12V65AH*18
PEC12-72*1
PRO806L
20/240VDC
C6*1
12V17AH*20
C12*1
12V26AH*20
C4*2
12V18AH*40
C20*1
12V26AH*40
PEC24-240*1
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V65AH*40
PEC24-240*1
PRO810L
20/240VDC
C12*1
12V26AH*20
C6*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*2
C20*3
12V65AH*60
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
3. Master Series (1P/1P) - 2-in-1 Rack/ Tower
BACK UP
TIME
POWER
RATING
BATTERY
GROUP
DC BUS
(VDC)
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO801RL
2/24VDC
G8R*1
12V7AH*8
C1*1
12V17AH*4
C2*1
12V65AH*2
C3*1
12V100AH*2
PEC20-24*1
C6*1
12V65AH*6
PEC20-24*1
C8*1
12V65AH*8
PEC20-24*1
PRO8015RL
3/36VDC
G12R*1
12V7AH*12
C2*1
12V17AH*6
C3*1
12V65AH*3
C3*1
12V100AH*3
PEC15-36*1
C6*1
12V100AH*6
PEC15-36*1
C12*1
12V65AH*12
PEC15-36*2
PRO802RL
4/48VDC
G20R*1
12V7AH*16
C2*1
12V17AH*8
C4*1
12V65AH*4
C4*1
12V100AH*4
PEC15-48*1
C12*1
12V65AH*12
PEC15-48*1
C16*1
12V65AH*16
PEC15-48*2
PRO803RL
6/72VDC
G12R*2
12V7AH*24
C3*1
12V17AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
PEC12-72*1
C20*1
12V65AH*18
PEC12-72*1
C24*1
12V65AH*24
PEC12-72*2
PRO806RL
20/240VDC
G20R*2
12V9AH*40
C12*1
12V26AH*20
C20*1
12V26AH*40
PEC24-240*1
C20*1
12V65AH*20
PEC24-240*1
C20*2
12V65AH*40
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
PRO810RL
20/240VDC
G20R*4
12V7AH*80
C20*1
12V26AH*40
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
The above battery backup configuration list is only applicable to the isolation transformer UPS version.
All specifications, designs and contents are subjected to changes without prior notice.
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
94
Appendix
4. Master Series (3P/1P) - Tower
BACK UP
TIME
POWER
RATING
BATTERY
GROUP
DC BUS
(VDC)
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83110L
20
C12*1
12V26AH*20
C6*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
PRO83115L
20
C6*2
12V17AH*40
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V100AH*40
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
PRO83120L
20
C12*2
12V26AH*40
C12*3
12V26AH*60
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
C20*4
12V100AH*80
PEC24-240*2
PRO83130L
20
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*5
12V100AH*100
PEC24-240*2
C20*7
12V100AH*140
PEC24-240*3
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
5. Master Series (3P/1P) - Rack Mount
BACK UP
TIME
POWER
RATING
BATTERY
GROUP
DC BUS
(VDC)
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83110RL
20
G20R*3
12V9AH*60
C4*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
PRO83120RL
20
C12*2
12V26AH*40
C12*3
12V26AH*60
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
C20*4
12V100AH*80
PEC24-240*2
REMARK
1. Without cable from UPS
system to battery bank.
2. All batteries supply are
without battery cables.
6. Master Series (3P/3P) - Tower
BACK UP
DC BUS
TIME
(VDC)
BATTERY
POWER
GROUP
RATING
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83310L
20
C12*1
12V26AH*20
C4*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
PRO83315L
20
C6*2
12V17AH*40
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V100AH*40
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
PRO83320L
20
C12*2
12V26AH*40
C12*3
12V26AH*60
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
C20*4
12V100AH*80
PEC24-240*2
PRO83330L
20
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*5
12V100AH*100
PEC24-240*2
C20*7
12V100AH*140
PEC24-240*3
The above battery backup configuration list is only applicable to the isolation transformer UPS version.
*All specifications, designs and contents are subject to change without prior notice.
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
95
Appendix
7. Power Series (3P/3P)
BACK UP
TIME
POWER
RATING
BATTERY
GROUP
DC BUS
(VDC)
15 MINUTES
30 MINUTES
1 HOURS
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
C16*2
12V17AH*124
C32*2
12V26AH*124
C32*2
12V100AH*62
C32*4
12V65AH*124
C16*1
12V17AH*62
PRO73315S
62
PRO73320S
62
C16*1
12V17AH*62
C32*1
12V26AH*62
C16*2
12V17AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*4
12V65AH*124
PRO73330S
62
C32*1
12V26AH*62
C16*2
12V17AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*4
12V100AH*124
PRO73340S
62
C16*2
12V17AH*124
C32*2
12V26AH*124
C32*2
12V100AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*8
12V65AH*248
PRO73360S
62
C32*2
12V26AH*124
C32*2
12V65AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*6
12V100AH*186
C32*8
12V100AH*248
PRO73380S
62
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*8
12V65AH*248
C32*8
12V100AH*248
C32*10
12V100AH*310
PRO733100S
62
C32*2
12V100AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*6
12V100AH*186
C32*10
12V100AH*310
C32*14
12V100AH*434
PRO733120S
62
C32*2
12V100AH*62
C32*4
12V100AH*124
C32*8
12V65AH*248
C32*8
12V100AH*248
C32*12
12V100AH*372
C32*16
12V100AH*496
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
Battery Configurations
CABINET WEIGHT
Available Battery Quantity
CABINET
DIMENSION
(D * W * H)
100AH
65AH
38AH
24AH
17AH
CI
C2
435*210*270
450*470*320
1
1
1
2
2
4
3
4
5
10
12V7AH or
12V9AH or 10Ah
/
/
C3
585*470*320
3
3
6
6
14
/
8kg
C4
C6
450*470*615
585*470*615
4
6
4
6
8
12
8
12
20
28
/
/
18kg
22kg
C8
780*470*615
8
8
16
16
36
/
25kg
C12
C16
780*470*900
780*470*1190
12
16
12
16
24
32
24
32
/
62
/
/
32kg
45kg
C20
950*470*1190
20
20
40
40
/
/
45kg
C24
C32
1150*470*1190
780*880*1190
24
32
24
32
/
62
/
62
/
/
/
/
75kg
95kg
MODEL NO
REMARK
3.5kg
6kg
1. Option for DC
switch/protection
2. Option for battery
cable inter
connection.
For Power Series
Included cables,
without switch
G6
6
Completed assembled
G12
12
Completed assembled
G18
G60
18
60
Completed assembled
completed assembled
G8R
8
Completed assembled
G12R
12
Completed assembled
G20R
20
Completed assembled
The above battery backup configuration list is only applicable to the isolation transformer UPS version.
*All specifications, designs and contents are subject to change without prior notice.
96
SINGAPORE
FIDA INTERNATIONAL (S) PTE LTD
Block 16 Kallang Place
#06-02, Singapore 339156
Tel: (65) 6357 0668
MALAYSIA
FIDA SYSTEMS (M) SDN BHD
Tel: (60) 3 8024 9151
INDONESIA
PROLiNK INDONESIA
Tel: (62) 21 3483 1777
Technical Support Hotline:
Singapore (65) 6357 0666
Malaysia (60) 3 8023 9151
Indonesia (62) 21 3483 1717
Operating Hours
Monday - Friday: 9.00am - 6.00pm
Closed on Saturdays, Sundays & Public Holidays