Specs - Juno Lighting Group

advertisement
K14.1.3.1
ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT
2X4 LED RECESSED
•The Indy 2x4 Architectural Lay-in Series delivers 3200 to 6100 LUMINAIRE with LAY-IN DIFFUSER
lumens while achieving up to 111 lumens per watt
•Direct/indirect distribution of soft light creates superior brightness S2X4LF, S2X4LI SERIES
control and balanced light
• No harmful ultraviolet or infrared wavelengths
Type
Cat. No.
• Contains no lead or mercury
PRODUCT SPECIFICATIONS
Project:
Optics
Directional optics (center panel): High transmission acrylic diffuser panel delivers main
beam focus while providing excellent control and efficiency • Illusion lens creates unique aesthetic with lighting patterns that appears to change when viewed at different angles
Diffuser Surround (side panels): Two (2) sloping high transmission acrylic diffuser panels
provide contrast and generate soft, even high angle luminance
Notes:
ILLUSION
Electrical
LED Light Engine: High-performance LEDs deliver consistent high-quality white light and
uniform illumination without pixilation • Consistent fixture-to-fixture color temperature within
3 MacAdam ellipses • Light engine/reflector system produces 3200 to 6100 lumens at 80
CRI, and 2600 to 5100 lumens at 90 CRI while using only 36 to 65 watts of energy • 3000K,
3500K, 4100K and 5000K color temperatures • 80 and 90 CRI options available • Easily
replaceable array boards allow for easy maintenance or updating technology
LED Driver: Accommodates 120-277V or 347V input volts AC at 50/60Hz
• Power factor >0.9 • Dimming standard to 10% with 0-10V DC control protocol • Dimmable
to 33% and 66% with optional step dimming • Easy access to driver from below ceiling • For
list of compatible dimmers see LED-DIM
Controls: Integrated open-standards ZigBee® wireless control. Interoperates with Daintree’s
ControlScope™ network wireless control solutions (-WCR Option).
Life: Rated for 50,000 hours at 70% lumen maintenance, 8-12 years commercial use expectancy
FLAT
DIMENSIONS
FLAT
5-3/4″
23-3/4″
ILLUSION
5-3/4″
Housing
23-3/4″
Cold rolled steel • Highly reflective white finish on phosphate-free, multi-staged pretreated
metal
Mounting
Lightweight and easy to install in any standard T-Bar system • Ideal for new construction and
remodel applications • Drywall frame available for plaster/drywall ceilings, see accessories.
•Consult factory for 9/16” grid applications
Labels and Listings
47-3/4″
•
•
•
•
Tested and certified to UL and CSA standards using ETL laboratories
ETL Listed for damp locations
DesignLights Consortium® Qualified as indicated below • I.B.E.W. Union made
ARRA Compliant
ENGINEERING DATA
Voltage
120V - 277V
Warranty:
Fixture Lumens
3200/26005100/42006100/5100
5 years when used in accordance with
CCT
3K/35K/4K/5K3K/35K/4K/5K3K/35K/4K/5K
manufacturing guidelines.
Input Wattage36W53W65W
Product specifications subject to change
Input Frequency50/60Hz50/60Hz50/60Hz
without notice.
Power Factor 0.90.90.9
ORDERING INFORMATION:
S2X4LF-5135U-WH3
Accessories ordered separately
Example:
Cat. #
Diffuser Style
Lumens
Color
Temp.
LF
80 CRI Only
30
Voltage
Finish
Generation
WH
3
U
WH
S2X4
S2X4
2’X4’
Solid State, LED
Flat Lay-In
LI
Illusion
Lay-In
32
120-277V
White
3
Gen3
BR Emergency Battery Pack w/ Remote Test Switch
AM Anti-Microbial Paint (Provides mildew and odor *51
5100 Lumens
35
3
Accessories
2X4DWA
resistance to product)
3500K
347V
NY 20 GA. Housing
51
WCR Wireless Control Ready Interoperates with Daintree
5100 Lumens
40
LDI Lumen Depreciation Indicator (Cannot be used 4100K
61
w/ BR Option or 347V)
6100 Lumen
50
S Step Dimming 33/66/100%
90 CRI Only
5000K
(not available for 5100, 6100 lumen or 347V)
*26
90 90 CRI
2600 Lumens
*Must add -90 suffix to catalog number for 90 CRI option
*42
3200 Lumens
4200 Lumens
11/15
Rev.1
3000K
Options
Related Products:
S2X2LF/LI K14.1.3
2’ X 4’ Drywall Frame
Adapter
DesignLights Consortium Qualified:
Product #
(120-277V)
S2X4LF-(XX)(YY)U-WH3
S2X4LI-(XX)(YY)U-WH3
(347V)
S2X4LF-(XX)(YY)3-WH3
S2X4LI-(XX)(YY)3-WH3
Fixture Configurations = DLC
Lumen Package: XX = 32, 51, 61
CCT: YY = 30, 35, 40, 50
Lumen Package: XX = 32, 51, 61
CCT: YY = 30, 35, 40, 50
1300 South Wolf Rd • Des Plaines, Illinois 60018
PHONE 800-367-5866 • FAX 888-708-6578
www.junolightinggroup.com
K14.1.3.1
PHOTOMETRIC REPORT
Catalog Number:
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0o45o90o
45° 18951793 1705
55° 17321614 1523
CCT MULTIPLIER:
3KX0.957 65° 15561429 1339
35KX0.980 75° 13311204 1115
5KX1.053 85° 966831 719
Zonal Lumen Summary
90º Zone
Lumens
%fixture
1071
31.0
85º 0-30°
0-40°
1698
49.2
0-60°
2821
81.7
75º 0-90°
3453
100.0
90-180°
0
0.0
0-180°
3453
100.0
S2X4LF-3240U-WH3
Total Lumen Output: 3453 Lumens
Luminaire EFFicacy: 98 lm/w
Luminaire Spacing Criteria: End = 1.18
Across = 1.14
Luminaire: 2’ X 4’ Flat Lay-in, White Frosted Diffuser.
CIE-Type: Direct
200
400
600
65º
800
55º
1000
1200
1400
45º
0˚
45˚
90˚
1600
0º 5º
15º
25º
PHOTOMETRIC REPORT
Catalog Number:
35º
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0o45o90o
45° 28852711 2594
55° 26362445 2327
CCT MULTIPLIER:
65° 23682167 2053
3KX0.957
75° 20281830 1715
35KX0.980
85° 14381285 1146
5KX1.053
Zonal Lumen Summary
90º Zone
Lumens
%fixture
1615
30.9
85º 0-30°
0-40°
2562
49.0
0-60°
4265
81.6
0-90°
5229
100.0
75º
90-180°
0
0.0
0-180°
5229
100.0
S2X4LF-5140U-WH3
Total Lumen Output: 5229 Lumens
Luminaire EFFicacy: 100 lm/w
Luminaire Spacing Criteria: End = 1.18
Across = 1.24
Luminaire: 2’ X 4’ Flat Lay-in, White Frosted Diffuser.
CIE-Type: Direct
200
400
600
800
65º
1000
1200
1400
1600
55º
1800
2000
2200
0˚
45˚
90˚
2400
0º 5º
15º
25º
PHOTOMETRIC REPORT
Catalog Number:
45º
35º
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 2188 2188 2188
5° 2174 2173 2176 206
15° 2067
2046 2028
576
25° 1864
1811 1770
834
35° 1584
1511 1457
947
45° 1266
1190 1138
921
55°938 870828783
65°621 568538567
75°326 294275314
85°
78 696282
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0º45º90º
45° 23602218 2122
55° 21572001 1904
CCT MULTIPLIER:
65° 19371773 1680
3KX0.957
75° 16591497 1403
35KX0.980
85° 11761051 938
5KX1.053
Zonal Lumen Summary
Lumens
%fixture
90º Zone
1322
30.9
85º 0-30°
0-40°
2096
49.0
0-60°
3490
81.6
0-90°
4278
100.0
75º
90-180°
0
0.0
0-180°
4278
100.0
S2X4LF-4240U-WH3-90
Total Lumen Output: 4278 Lumens
Luminaire EFFicacy: 82 lm/w
Luminaire Spacing Criteria: End = 1.20
Across = 1.12
Luminaire: 2’ X 4’ Flat Lay-in, White Frosted Diffuser.
CIE-Type: Direct
200
400
600
800
1000
65º
1200
1400
55º
1600
1800
2000
2200
0˚
45˚
90˚
2400
0º 5º
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 1447 1447 1447
5° 1436 1438 1440 136
15° 1363
1356 1347
381
25° 1232
1203 1178
553
35° 1043
1003
966
627
45°831 787748608
55°616 574542515
65°408 375351373
75°214 193179206
85°
52 453953
15º
25º
35º
45º
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 1791 1791 1791
5° 1778 1777 1780 168
15° 1691
1674 1659
471
25° 1525
1482 1448
682
35° 1296
1237 1192
775
45°
1036973931753
55°768 712678640
65°508 464440464
75°266 240225257
85°
64 575167
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
145
99
68
6’ x 6’
101
69
47
7’ x 7’
74
51
35
8’ x 8’
57
39
26
9’ x 9’
45
31
21
10’ x 10’
36
25
17
11’ x 11’
30
21
14
12’ x 12’
25
17
12
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110106102 99 107 104100 97 99 96 94 9593 91 929088
2 101 9488 83 99 9287 82 89 84 80 8682 78 838077
3 93 8477 71 91 8276 70 80 74 69 7772 68 747067
4 86 7668 62 84 7467 61 72 66 61 7064 60 686359
5 80 6860 54 78 6759 53 65 58 53 6357 52 615652
6 74 6153 47 72 6053 47 59 52 46 5751 46 565046
7 68 5547 41 67 5547 41 53 46 41 5145 40 504540
8 63 5042 37 62 5042 37 48 41 36 4741 36 464036
9 59 4638 33 57 4538 33 44 37 32 4337 32 423632
10 55 4234 29 54 4234 29 41 34 29 4033 29 393329
0
0
100
86
75
65
57
50
44
38
34
30
27
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
220
151
102
6’ x 6’
153
105
71
7’ x 7’
112
77
52
8’ x 8’
86
59
40
9’ x 9’
68
46
32
10’ x 10’
55
38
26
11’ x 11’
45
31
21
12’ x 12’
38
26
18
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110106102 99 107 104100 97 99 96 94 9593 91 929088
2 101 9488 83 99 9287 82 89 84 80 8682 78 838077
3 93 8477 71 91 8276 70 80 74 69 7772 68 747067
4 86 7668 62 84 7467 61 72 65 60 7064 60 686359
5 80 6860 54 78 6759 53 65 58 53 6357 52 615652
6 74 6153 47 72 6052 47 59 52 46 5751 46 565046
7 68 5547 41 66 5447 41 53 46 41 5145 40 504440
8 63 5042 37 62 5042 36 48 41 36 4741 36 464036
9 59 4638 33 57 4538 33 44 37 32 4337 32 423632
10 55 4234 29 54 4134 29 40 34 29 4033 29 393328
0
0
100
86
75
65
57
50
44
38
34
30
27
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
181
130
86
6’ x 6’
126
90
59
7’ x 7’
93
66
44
8’ x 8’
71
51
33
9’ x 9’
56
40
26
10’ x 10’
45
33
21
11’ x 11’
37
27
18
12’ x 12’
31
23
15
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110106102 99 107 104100 97 99 96 94 9593 91 929088
2 101 9488 83 99 9287 82 89 84 80 8682 78 838077
3 93 8477 71 91 8276 70 80 74 69 7772 68 747067
4 86 7668 62 84 7467 61 72 65 60 7064 60 686359
5 80 6860 54 78 6759 53 65 58 53 6357 52 615652
6 74 6153 47 72 6052 47 59 52 46 5751 46 565046
7 68 5547 41 66 5447 41 53 46 41 5145 40 504440
8 63 5042 37 62 5042 36 48 41 36 4741 36 464036
9 59 4638 33 57 4538 33 44 37 32 4337 32 423632
10 55 4234 29 54 4134 29 40 34 29 4033 29 393328
0
0
100
86
75
65
57
50
44
38
34
30
27
Fixture photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08.
IESNA LM-79-08 specifies the entire luminaire as the source resulting in a fixture efficiency of 100%.
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578
Visit us at www.junolightinggroup.com
Printed in U.S.A. ©2016 Acuity Brands Lighting, Inc.
K14.1.3.1
PHOTOMETRIC REPORT
Catalog Number:
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0o45o90o
45° 33803168 3036
55° 31102868 2726
CCT MULTIPLIER:
3KX0.957 65° 28072547 2407
35KX0.980 75° 24012134 2006
5KX1.053 85° 16981426 1276
S2X4LF-6140U-WH3
Total Lumen Output: 6231 Lumens
Luminaire EFFicacy: 94 lm/w
Luminaire Spacing Criteria: End = 1.20
Across = 1.14
Luminaire: 2’ X 4’ Flat Lay-in, White Frosted Diffuser.
CIE-Type: Direct
90º
85º
200
400
600
75º
800
1000
1200
65º
1400
1600
1800
2000
55º
0˚
45˚
90˚
2200
2400
0º 5º
15º
25º
45º
35º
PHOTOMETRIC REPORT
Catalog Number:
S2X4LI-3240U-WH3
Total Lumen Output: 3680 Lumens
Luminaire EFFicacy: 104 lm/w
Luminaire Spacing Criteria: End = 1.18
Across = 1.26
Luminaire: 2’ X 4’ Illusion, White Frosted Diffuser.
CIE-Type: Direct
CCT MULTIPLIER:
3KX0.957
35KX0.980
5KX1.053
200
90º
85º
400
75º
600
65º
800
55º
1000
1200
1400
0˚
45˚
90˚
1600
0º 5º
15º
25º
PHOTOMETRIC REPORT
Catalog Number:
45º
35º
Summary
Lumens
1922
3051
5083
6231
0
6231
%fixture
30.8
49.0
81.6
100.0
0.0
100.0
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 2596 2596 2596
5° 2568 2572 2589 244
15° 2444
2427 2417
684
25° 2208
2153 2116
993
35°1884 180017421129
45°1708 141313541097
55° 1125
1038
986
935
65°748 679642679
75°392 348328375
85°
93 787095
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0o45o90o
45° 18992048 2040
55° 16311737 1620
65° 13141374 1216
75° 8991148 1003
85° 5021117 624
Zonal Lumen
Zone
0-30°
0-40°
0-60°
0-90°
90-180°
0-180°
Summary
Lumens
1168
1879
3096
3680
0
3680
%fixture
31.7
51.1
84.1
100.0
0.0
100.0
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 1514 1514 1514
5° 1502 1510 1515 143
15° 1437
1458 1470
410
25° 1296
1344 1365
614
35° 1084
1149 1172
711
45°833 898895680
55°581 618576537
65°345 360319347
75°144 184161184
85°
27 603453
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0o45o90o
45° 29053110 3012
55° 24832634 2406
CCT MULTIPLIER:
3KX0.957 65° 19952093 1825
35KX0.980 75° 13481732 1467
5KX1.053 85° 7111685 1117
S2X4LI-5140U-WH3
Total Lumen Output: 5583 Lumens
Luminaire EFFicacy: 107 lm/w
Luminaire Spacing Criteria: End = 1.18
Across = 1.24
Luminaire: 2’ X 4’ Illusion, White Frosted Diffuser.
CIE-Type: Direct
90º
85º
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
75º
65º
55º
0˚
45˚
90˚
0º 5º
Zonal Lumen
Zone
0-30°
0-40°
0-60°
0-90°
90-180°
0-180°
15º
25º
35º
45º
Zonal Lumen
Zone
0-30°
0-40°
0-60°
0-90°
90-180°
0-180°
Summary
Lumens
1789
2870
4705
5583
0
5583
%fixture
32.0
51.4
84.3
100.0
0.0
100.0
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 2334 2334 2334
5° 2317 2326 2333 221
15° 2219
2238 2250
630
25° 1992
2052 2069
938
35°1662 175317601081
45°1274 136513221026
55°884 937856809
65°523 549479525
75°217 278236274
85°
38 916080
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
262
179
122
6’ x 6’
182
125
85
7’ x 7’
134
92
62
8’ x 8’
102
70
48
9’ x 9’
81
55
38
10’ x 10’
65
45
31
11’ x 11’
54
37
25
12’ x 12’
45
31
21
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 109105101 97 107 10299 95 98 95 92 9492 90 918987
2 100 9285 80 97 9084 79 86 81 77 8379 75 807774
3 91 8173 67 89 8072 66 77 70 65 7469 64 716763
4 84 7264 57 82 7163 57 68 62 56 6660 55 645955
5 77 6556 50 75 6456 49 62 54 49 6053 48 585248
6 72 5950 44 70 5849 43 56 49 43 5448 43 534742
7 67 5345 39 65 5344 39 51 44 38 5043 38 484238
8 62 4940 35 60 4840 35 47 40 34 4639 34 443834
9 58 4537 31 57 4437 31 43 36 31 4236 31 413531
10 55 4234 29 53 4134 29 40 33 28 3933 28 383228
0
0
100
85
71
61
52
46
40
36
32
29
26
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
155
107
74
6’ x 6’
107
75
51
7’ x 7’
79
55
38
8’ x 8’
60
42
29
9’ x 9’
48
33
23
10’ x 10’
39
27
18
11’ x 11’
32
22
15
12’ x 12’
27
19
13
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110106103 99 108 104101 98 10097 95 9694 92 929189
2 102 9589 84 100 9388 83 90 85 81 8783 80 848178
3 94 8578 72 92 8377 72 81 75 70 7873 69 767268
4 87 7769 63 85 7669 63 73 67 62 7166 61 696460
5 81 6961 55 79 6860 55 66 59 54 6458 54 625753
6 75 6354 49 73 6254 48 60 53 48 5852 47 575147
7 69 5648 43 67 5648 42 54 47 42 5346 42 514641
8 64 5143 38 63 5043 38 49 42 37 4842 37 474137
9 59 4739 33 58 4639 33 45 38 33 4438 33 433733
10 55 4335 30 54 4235 30 41 34 30 4034 29 393429
0
0
100
87
76
66
58
51
45
39
35
31
28
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
234
165
112
6’ x 6’
163
115
78
7’ x 7’
120
84
57
8’ x 8’
92
65
44
9’ x 9’
72
51
34
10’ x 10’
59
41
28
11’ x 11’
48
34
23
12’ x 12’
41
29
19
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110106103 99 108 104101 98 10097 95 9694 92 939189
2 102 9590 84 100 9388 83 90 85 82 8783 80 848178
3 94 8578 72 92 8477 72 81 75 71 7874 69 767268
4 87 7769 63 85 7669 63 73 67 62 7166 61 696461
5 81 7061 55 79 6861 55 66 60 55 6458 54 635853
6 75 6355 49 73 6254 48 60 53 48 5852 48 575147
7 69 5748 43 68 5648 42 54 47 42 5346 42 524642
8 64 5144 38 63 5143 38 49 43 38 4842 37 474137
9 60 4739 34 58 4639 34 45 38 33 4438 33 433733
10 55 4335 30 54 4235 30 41 35 30 4034 30 403429
0
0
100
87
76
66
59
52
45
40
35
31
28
Fixture photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08.
IESNA LM-79-08 specifies the entire luminaire as the source resulting in a fixture efficiency of 100%.
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578
Visit us at www.junolightinggroup.com
Printed in U.S.A. ©2016 Acuity Brands Lighting, Inc.
K14.1.3.1
PHOTOMETRIC REPORT
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
Catalog Number:
in Degrees
0o45o90o
Total Lumen Output: 6731 Lumens
45° 34403657 3596
Luminaire EFFicacy: 102 lm/w
55°
29663125
2922
Luminaire Spacing Criteria: End = 1.20
CCT MULTIPLIER:
Across = 1.24
3KX0.957 65° 23972516 2215
Luminaire: 2’ X 4’ Illusion Lay-in, White Frosted Diffuser. 35KX0.980 75° 16202107 1895
5KX1.053 85° 8532094 1382
CIE-Type: Direct
S2X4LI-6140U-WH3
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
90º
85º
75º
65º
55º
0˚
45˚
90˚
0º 5º
15º
25º
45º
35º
Zonal Lumen
Zone
0-30°
0-40°
0-60°
0-90°
90-180°
0-180°
Summary
Lumens
2137
3433
5650
6731
0
6731
%fixture
31.7
51.0
83.9
100.0
0.0
100.0
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 2785 2785 2785
5° 2753 2766 2790 263
15° 2642
2667 2684
752
25°2382 244024671121
35°1996 209221131296
45°1534 163116041234
55° 1073
1131 1057
983
65°639 671590642
75°265 344309339
85°47 11576100
PHOTOMETRIC REPORT
Luminance Data (Candela/M)
Angle Avg.Avg. Avg.
in Degrees
0º45º90º
Total Lumen Output: 5513 Lumens
45° 28172995 2945
Luminaire EFFicacy: 83 lm/w
55° 24292559 2393
Luminaire Spacing Criteria: End = 1.20
CCT MULTIPLIER:
Across = 1.24
3KX0.957 65° 19632060 1814
Luminaire: 2’ X 4’ Illusion Lay-in, White Frosted Diffuser. 35KX0.980 75° 13271725 1552
5KX1.053 85° 6981715 1132
CIE-Type: Direct
Catalog Number:
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
S2X4LI-5140U-WH3-90
90º
85º
75º
65º
55º
0˚
45˚
90˚
0º 5º
15º
25º
35º
45º
Zonal Lumen
Zone
0-30°
0-40°
0-60°
0-90°
90-180°
0-180°
Summary
Lumens
1750
2811
4626
5513
0
5513
%fixture
31.7
51.0
83.9
100.0
0.0
100.0
Candlepower Distribution (Candelas)
Candela
Angle
Lumens
0.0 45.0 90.0
0° 2281 2281 2281
5° 2255 2265 2285 216
15° 2163
2185 2198
616
25° 1951
1999 2020
918
35°1635 171317301062
45°1257 133613141011
55°879 926866805
65°523 549484526
75°217 282253278
85°
38 946282
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
283
197
135
6’ x 6’
196
136
93
7’ x 7’
144
100
69
8’ x 8’
110
77
53
9’ x 9’
87
61
42
10’ x 10’
71
49
34
11’ x 11’
58
41
28
12’ x 12’
49
34
23
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110105101 98 107 10399 96 99 96 93 9592 90 918988
2 100 9386 81 98 9185 80 87 82 78 8480 76 817875
3 92 8274 68 90 8173 68 78 72 67 7570 65 726864
4 85 7365 59 82 7264 58 70 63 57 6761 57 656056
5 78 6657 51 76 6557 51 63 56 50 6155 50 595349
6 72 6051 45 71 5951 45 57 50 44 5549 44 544844
7 67 5446 40 66 5345 40 52 45 39 5144 39 494339
8 63 5041 36 61 4941 36 48 41 35 4640 35 453935
9 59 4638 32 57 4537 32 44 37 32 4337 32 423632
10 55 4235 29 54 4234 29 41 34 29 4034 29 393329
0
0
100
85
73
62
54
47
42
37
33
30
27
AVERAGE INITIAL FOOTCANDLES
Reflectances: 80% Ceiling, 50% Walls, 30% Floors
Luminaire
Room Cavity Ratio
Spacing
RCR1RCR4RCR8
5’ x 5’
232
161
110
6’ x 6’
161
112
77
7’ x 7’
118
82
56
8’ x 8’
90
63
43
9’ x 9’
71
50
34
10’ x 10’
58
40
28
11’ x 11’
48
33
23
12’ x 12’
40
28
19
COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method)
Effective Floor Reflectance 20%
PCC
80
70 503010
PW 70 5030 10 70 5030 10 50 30 10 5030 10 503010
0 119 119119 119 116 116116 116 111 111 111 106106 106 102102102
1 110105101 98 107 10399 96 99 96 93 9592 90 918988
2 100 9386 81 98 9185 80 87 82 78 8480 76 817875
3 92 8274 68 90 8173 68 78 72 67 7570 65 726864
4 85 7365 59 82 7264 58 70 63 57 6761 57 656056
5 78 6657 51 76 6557 51 63 56 50 6155 50 595349
6 72 6051 45 71 5951 45 57 50 44 5549 44 544844
7 67 5446 40 66 5345 40 52 45 39 5144 39 494339
8 63 5041 36 61 4941 36 48 41 35 4640 35 453935
9 59 4638 32 57 4537 32 44 37 32 4337 32 423632
10 55 4235 29 54 4234 29 41 34 29 4034 29 393329
0
0
100
85
73
62
54
47
42
37
33
30
27
Fixture photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08.
IESNA LM-79-08 specifies the entire luminaire as the source resulting in a fixture efficiency of 100%.
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578
Visit us at www.junolightinggroup.com
Printed in U.S.A. ©2016 Acuity Brands Lighting, Inc.
Download