DESCRIPTION
A
B
BULLETIN 2-
CROSSROADS SHOPPING CENTER
SHT#
BULLETIN 1-
TENANT IMPROVEMENT:
BULLETIN 1-
SHEET INDEX
1
2
3
GENERAL
G-101
TITLE SHEET
G-102
GENERAL NOTES
G-103
ACCESSIBLE NOTES
G-501
TYPICAL ADA DETAILS
Seal:
ARCHITECTURAL
PLAN CHANGE DELTA
X
LETTERS FOR ADDENDA
NUMBERS FOR BULLETINS
SECTION CUT
IDENTIFIER
0
SECTION NUMBER
SHEET NUMBER
A000
0
DETAIL CALLOUT
IDENTIFIER
DETAIL NUMBER
SHEET NUMBER
A000
LEGAL JURISDICTION:
LEGAL DESCRIPTION:
NUMBER OF STORIES:
BUILDING AREA (EXISTING):
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
ZONING:
OF PLACER COUNTY, CA
APN 052-480-005-000
1 STORY
+/- 6,800 S.F. (GROSS)
M
V-B FULLY SPRINKLER (EXISTING)
CPD-Dc
TENANT CONTACTS:
0
INTERIOR ELEVATION
IDENTIFIER
ELEVATION NUMBER
SHEET NUMBER
A000
D
A
ELEVATION LETTER
0
ELEVATION NUMBER
SHEET NUMBER
A000
B
M - MERCANTILE (STOCK & STORAGE)
BUILDING IDENTIFIER
PRIMARY NAME
SQUARE FOOTAGE
NAME2
SECONDARY NAME
FINISHED FLOOR ELEVATION
FFE ffe
ROOM AND/OR
SPACE IDENTIFIER
ROOM NAME 1
ROOM NAME 2
XXX
DOOR IDENTIFIER
XXX
GLAZING (WINDOW)
IDENTIFIER
XXX
WALL (TYPE)
IDENTIFIER
EQUIPMENT IDENTIFIER
FLOOR FINISH
IDENTIFIER
XXX
XXXXX
PRIMARY NAME
SECONDARY NAME
ROOM AND/OR SPACE NUMBER
FIXTURE AND EQUIPMENT PLAN
A-103
FINISH FLOOR PLAN
A-121
PROPOSED REFLECTED CEILING PLAN
A-141
ROOF PLAN
A-201
EXTERIOR ELEVATIONS
A-401
INTERIOR ELEVATIONS
A-402
INTERIOR ELEVATIONS
A-403
INTERIOR ELEVATIONS
A-501
DETAILS
A-502
DETAILS
A-503
DETAILS
A-601
SCHEDULES
A Project for:
M-1
M-2
KORNWASSER SHOPPING CENTER PROPERTIES, LLC
5670 WILSHIRE BLVD. STE 1250
LOS ANGELES, CA 90036
Tel. No.: 323-965-1511
Contact: SUE JAGODZINSKI, LEED AP
E-Mail: suej@kornwasser.net
M-3
FLOOR PLAN
M-4
ROOF PLAN
TOTAL OCCUPANT LOAD = 189
NUMBER OF EXITS REQUIRED:
2 EXITS
NUMBER OF EXITS PROVIDED:
2 EXITS
TOTAL EXIT WIDTH REQUIRED:
189 x .20 = 37.8 INCHES
ARCHITECT:
TOTAL EXIT WIDTH PROVIDED:
MCG ARCHITECTURE
111 PACIFICA, STE. 280
IRVINE, CA 92618
Tel. No.: (949) 553-1117
Fax. No.: (949) 474-7056
Contact: ROBERT NAVA
E-Mail: RNAVA@MCGARCHITECTURE.COM
3'-1" FEET
D-1 @ 6', D-2 @ 3'
MECHANICAL
PLUMBING:
MECHANICAL BUILDING
SYSTEM ENGINEERING
31332 VIA COLINAS SUITE 112
WESTLAKE VILLAGE, CA 91362
Tel. No.: (818) 735 5551
Fax. No.: (818) 735 5554
Contact: WILL BOOTH
DIM TO FACE OF STUD TYP (UNO)
REFER TO GENERAL NOTES 15 & 16,
SHEET G101.
0 sf
A-102
MECHANICAL
314 SQ. FT. / 300 GROSS = 1 OCC.
= 9'-0" FEET
NAME1
PROPOSED FLOOR PLAN
RUE 21
STORE DESIGN COORDINATOR
BRADLY SCHAEFER
00
DIMENSION
A-101
REGIONAL DIRECTOR OF CONSTRUCTION
DAVE DICARLO
(724) 814-1407
5,653 SQ. FT. / 30 GROSS = 188 OCC.
C
GRID IDENTIFIER
DEMOLITION REFLECTED CEILING PLAN
DIRECTOR OF STORE DESIGN
JEFF LITCHED
(724) 741-9632
OCCUPANT LOAD:
EXTERIOR ELEVATION
IDENTIFIER
D-201
DIRECTORY
OWNER:
M - MERCANTILE (RETAIL)
DEMOLITION FLOOR PLAN
ELECTRICAL:
CODE REGULATIONS
B & A INC.
1106 W. MAGNOLIA BLVD.
BURBANK, CA. 91506
PH: (818) 840-8424
Contact: MEL FAJARDO
E-Mail: mel@avbengineers.com
ELECTRICAL
E-1.0
E-2.0
LIGHTING PLAN
E-2.1
LIGHTING DEMOLITION PLAN
E-2.2
LIGHTING PHOTOMETRIC PLAN
E-3.0
POWER AND SYSTEMS PLAN
E-3.1
POWER AND SYSTEMS DEMOLITION PLAN
E-4.0
SINGLE LINE AND PANEL SCHEDULES
E-5.0
TITLE 24 COMPLIANCE FORMS
PLUMBING
CITY OF PLACER COUNTY ADOPTED CODE
2013 CALIFORNIA BUILDING CODE
2013 CALIFORNIA ELECTRICAL CODE
2013 CALIFORNIA MECHANICAL CODE
2013 CALIFORNIA PLUMBING CODE
2013 CALIFORNIA FIRE CODE
2013 CALIFORNIA ENERGY CODE
P100
WASTE & VENT PLAN
P200
HOT & COLD WATER FLOOR PLAN
P300
PLUMBING DETAILS
P400
PLUMBING SPECS
2580 BELL ROAD
AUBURN, CA 95603
BUILDING DATA
LEGEND
D-101
TENANT IMPROVEMENT
ABBREVIATIONS
SITE PLAN - FOR REFERENCE
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
2580 BELL ROAD
AUBURN, CA 95603
AS-001
Client:
SUITE 3
1,693/ 30 = 56.43 OCC
1-500 OCC = 2 EXITS REQ'D
2 PROVIDED
EXIT WIDTH= 56.43 (.20)
11.26" REQUIRED
72" PROVIDED
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
SUITES 5, 6,
1,258/ 30 = 42 OCC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
XXXX-00
Revisions:
CEILING HEIGHT
IDENTIFIER
CLNG HT 0'-0"
PARKING COUNT
IDENTIFIER
XX
KEY NOTE IDENTIFIER
XXX
REFER TO KEY NOTE LEGEND
INTERIOR WALL
FINISH IDENTIFIER
XX
REFER TO LEGEND
OF WALL FINISHES
EXTERIOR FINISH &
MATERIAL IDENTIFIER
AA
XX
MATERIAL LETTER
FINISH/COLOR NUMBER
(REFER TO EXTERIOR FINISH
SCHEDULE FOR DETAILS)
ELEVATION LABEL
(ROOF HEIGHTS)
ELEVATION LABEL
(DETAILS /
SECTIONS /
ELEVATIONS)
TO-
1ST FLOOR
ELEV. 0'-0" AFF
ELEVATION
TOP OF [SPECIFED OBJECT]
TOP OF [SPECIFED OBJECT]
ELEVATION
SCOPE OF WORK
VICINITY MAP
DESCRIPTION
1. INTERIOR TENANT IMPROVEMENT FOR ABOVE ADDRESS.
SCOPE OF WORK TO INCLUDE:
- NEW INTERIOR NON-BEARING WALLS
- NEW ADA RESTROOMS AND PLUMBING FIXTURE
- CASEWORK
- ROOM FINISHES
- LIGHTING
PROJECT
SITE
No.
Description
Project No.:
Drawn By:
Reviewed By:
2. MINOR DEMOLITION OF INTERIOR (NON-BEARING) PARTITIONS
Scale:
Date:
Date
15.083.10
JA
RN
AS NOTED
03-11-15
Filename:
SEPARATE SUBMITTAL
Sheet Title:
1. SIGNAGE
2. SPRINKLER MODIFICATIONS
TITLE SHEET
Sheet #:
G-101
NOT TO SCALE
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
EXISTING PARKING STRIP AND ACCESSIBLE SYMBOL, TO REMAIN
02
EXISTING ACCESSIBILITY ENTRY SIGNAGE TO REMAIN
03
EXISTING CONCRETE CURB RAMP, TO REMAIN
04
EXISTING ACCESSIBLE PARKING SIGNAGE TO REMAIN
05
(E) VAN ACCESSIBLE PARKING SPACE
06
(E) PARKING SPACE FOR OFF STREET PARKING SIGNAGE
07
(E) PARKING STRIP, TO REMAIN
08
(E) LANDSCAPE, TO REMAIN
Seal:
08
03
06
08
08
KEYNOTES
SCALE
-
-
(E)12'-0"
(E)9'-0"
04
(E)20'-0"
02
07
(E)30'-0"
(E)20'-0"
08
7 STALLS @ 9' = 63'-0"
01
08
(E)20'-0"
07
(E)26'-0"
(E)20'-0"
(E)20'-0"
07
Client:
(E)29'-2"
08
8 STALLS @
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
08
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
9' = 72'-1"
Revisions:
07
(E)18'-0"
05
8 STALLS @ 9' = 72'-0"
(E) SLOPE
(E)10'-0"
01
9 STALL @ 9' = 91'-0"
+/-6,800 SQ. FT.
BUILDING A
"M" OCCUPANCY
TYPE V-B (FULLY
SPRINKLED)
(E)5'-0"
(E)9'-0"
03
04
NO
PARKING
(E)5'-0"
TENANT IMPROVEMENT
(E)5'-6"
Q U A R T Z
08
2580 BELL ROAD
AUBURN, CA 95603
(E)28'-7"
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
A Project for:
(E)6'-8"
D R I V E
08
01
EXISTING ACCESSIBLE PATH OF TRAVEL,
No.
EXISTING EGRESS PATH OF TRAVEL,
Description
Project No.:
Drawn By:
Reviewed By:
Scale:
Date:
LEGEND
SCALE
-
-
Date
15.083.10
JA
RN
AS NOTED
03-11-15
Filename:
Sheet Title:
SITE PLAN
(FOR REFERENCE)
N
B E L L
1.
"ALL ACCESSIBILITY REQUIREMENTS IN THE PRIMARY PATH OF TRAVEL FROM THE
PRIMARY ENTRANCE TO THIS ALTERATION AREA HAS BEEN COMPLETED AND APPEAR TO
SUBSTANTIALLY CONFORM TO THE APPLICABLE. CALIFORNIA BUILDING STANDARD
CODE. FIELD VERIFICATIONS IS REQUIRED."
R O A D
SITE PLAN - FOR REFERENCE ONLY
SCALE
1" = 10'
1
GENERAL NOTES
SCALE
-
Sheet #:
AS-001
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
07
04
16
06
11
16
7
TOILET
ROOM
-
TOILET
ROOM
-
15
12
12
12
REMOVE EXISTING PARTITION(S) AS SHOWN DASHED, INCLUDING ANY ELECTRICAL
DEVICES, DOORS, FINISHES, AND OTHER ASSOCIATED ITEMS, VERIFY IN FIELD.
03
REMOVE EXISTING DOOR, FRAME AND HARDWARE (SHOWN DASHED)
IN IT'S ENTIRELY
04
REMOVE ALL EXISTING FINISH IN IT'S ENTIRELY.
05
REMOVE EXISTING INTERIOR GLAZING PARTITIONS (SHOWN DASHED)
IN IT'S ENTIRELY.
06
12
03
07
02
07
03
16
08
03
07
3'-5"
C
(E OL.
)
02
12
6
13
12
16
04
7'-9"
08
04
15
STAFF
AREA
-
REMOVE PORTION OF EXISTING STOREFRONT SYSTEM (SHOWN DASHED) AS
REQUIRED FOR NEW STOREFRONT ENTRY LOCATION.
11
EXISTING STOREFRONT TO REMAIN. CLEAN/REFURBISH AS REQUIRED TO ENSURE
LIKE NEW CONDITION. REMOVE BLOCK KNEE WALL AND INFILL WITH GLAZING TO
MATCH EXISTING.
12
EXISTING PARTITION TO REMAIN. REMOVE EXISTING TENANT FINISHES.
PATCH/REPAIR AND PREP TO RECEIVE NEW TENANT FINISHES.
15
15
16
02
EXISTING STRUCTURAL COLUMN TO REMAIN. REMOVE EXISTING COLUMN
ENCLOSURE IN IT'S ENTIRELY. VERIFY EXISTING CONDITION BEHIND COLUMN
WRAP (IE. ROOF DRAINS) AND REPORT FINDINGS TO REU2I PRIOR TO DEMOLITION.
CLEAN/SAND COLUMNS SMOOTH AND PREP TO RECEIVE NEW FINISHES.
10
14
5
REMOVE EXISTING PLUMBING FIXTURE IN IT'S ENTIRELY AND CAP ALL UNUSED
PLUMBING LINES FLUSH WITH CONCRETE SLAB IN COMPLIANCE WITH THE
APPLICABLE BUILDING CODES. REPAIR ANY HOLES OR DAMAGE TO THE CONCRETE
SLAB TO PROVIDE A SMOOTH AND LEVEL SURFACE - SEE ALSO PLUMBING
DRAWINGS
REMOVE EXISTING STOREFRONT DOORS (SHOWN DASHED) IN IT'S ENTIRELY.
INFILL OPENING TO MATCH EXISTING STOREFRONT WALL/GLAZING SYSTEM.
13
14
EXISTING TELEPHONE PANEL, FIRE ALARM, SERVER, TO BE RELOCATED/ REMOVE,
GC TO COORDINATE W RUE 21 & CONSTRUCTION MANAGER
EXISTING POWER OUTLETS TO BE RELOCATED PER NEW CONSTRUCTION
CANOPY OVERHANG ABOVE
SCALE
-
C
(E OL.
)
08
09
SALES
AREA
-
12
15
09
05
TYP.
15
-
1.
DO NOT SCALE DRAWINGS.
2.
THE GC SHALL BE RESPONSIBLE FOR ALL DEMOLITION DESCRIBED ON THESE
DRAWINGS AND ANY OTHER DEMOLITION THAT MAY BE DIRECTED, IN WRITING BY THE
ARCHITECT, NOT SPECIFICALLY NOTED ON THESE DRAWINGS.
3.
GC SHALL PROVIDE TO RUE2I PHOTOGRAPHS AND ALL FIELD DIMENSIONS AFTER
DEMOLITION IS COMPLETE OF ENTIRE SPACE.
4.
THE GC SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES REQUIRED
FOR COMPLETE INTERIOR DEMOLITION REMOVALS AND RELATED WORK AS INDICATED
AND SPECIFIED HEREIN, AND AS REASONABLY IMPLIED TO COMPLETE THE WORK IN ALL
RESPECTS.
5.
THE GC SHALL REPAIR AT THEIR OWN EXPENSE ANY DAMAGE DONE TO THE OWNERS
PROPERTY, AND ANY OTHER PERSON OR PERSONS ON OR OFF THE PREMISES AS A
RESULT OF THE GC'S WORK DEFINED HEREIN.
6.
SALVAGE: REMOVE, REPAIR, CLEAN & STORE REMOVED ITEMS AS MAY BE DIRECTED
FOR RE-USE BY THE ARCHITECT AND/OR OWNER
7.
REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND/OR SPRINKLER
DRAWINGS FOR ANY ADDITIONAL DEMOLITION NOTES.
8.
REMOVE ALL ABANDONED MATERIALS, DEVICES, FIXTURES, PIPES, CONDUITS, WIRES,
ETC. FROM PREMISES INCLUDING THE AREA OF THE CEILING PLENUM AND CONNECTION
POINTS OUTSIDE OF THE TENANT SPACE. RETURN THE TENANT SPACE TO BASE
BUILDING CONDITIONS.
9.
REMOVE ALL EXISTING STORE FIXTURES AND CASHWRAP(S) COMPLETE.
15
4
A Project for:
REMOVE LADDER/ROOF ACCESS, REFER TO SHEET A-141 FOR MORE INFORMATION
DEMOLITION KEYNOTES
11
05
Seal:
09
11
01
EXISTING DOOR AND FRAME TO REMAIN. REMOVE EXISTING HARDWARE AND
REPLACE WITH NEW AS SPECIFIED ON SHEET A-601. EVALUATE EXISTING
CONDITION. REPORT FINDING TO RUE 2I IF REPLACEMENT IS REQUIRED. SEE
FLOOR PLAN A-101 AND SHEET A-601 FOR ADDITION INFORMATION
16
11'-4"
10. REMOVE ALL EXISTING WALL FIXTURES COMPLETE FOR STORE LAYOUT. PATCH/REPAIR
WALLS TO RECEIVE NEW TENANT FINISHES.
11. REMOVE ALL EXISTING FINISHED FLOOR MATERIALS DOWN TO THE EXISTING CONCRETE
SLAB UNLESS NOTED OTHERWISE.
1
2580 BELL ROAD
AUBURN, CA 95603
04
C
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
B
EXISTING ELECTRICAL EQUIPMENT AND SERVICE TO REMAIN. LANDLORD GC TO
ENSURE EXISTING SERVICE MEETS OR EXCEEDS TENANT ELECTRICAL
REQUIREMENTS. LANDLORD GC MUST ADD SERVICE AS REQUIRED
TENANT IMPROVEMENT
A
01
12. REMOVE EXISTING FINISHES FROM ALL EXISTING PARTITIONS TO REMAIN.
A-201
13. GC TO VISIT SITE PRIOR TO START OF WORK TO DETERMINE EXTENT OF DEMOLITION
REQUIRED TO PROCEED WITH INSTALLATION OF THIS PROJECT AS NOTED. IF ANY
DISCREPANCIES OCCUR, OR POTENTIAL CONFLICTS, CONTACT ARCHITECT AND RUE2I
PROJECT MANAGER
10
14. MAINTAIN ALL FIRE RATINGS AS REQUIRED BY LOCAL CODES, LANDLORD < FIRE
AUTHORITIES. IF EXISTING, REPAIR ANY FIRE PROOFING ON EXISTING STRUCTURAL
STEEL MEMBERS WHETHER IT BE SPRAY-ON OR OTHER AFTER DEMO.
15. COORDINATE THE MOVEMENT OF CONSTRUCTION MATERIALS AND EQUIPMENT, TRASH
REMOVAL, TEMPORARY ELECTRIC, AND REMOVAL OF BARRICADE WITH THE LANDLORD.
11
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
16. PROVIDE ADEQUATE PROTECTION FOR ALL FINISHED FLOORS TO REMAIN DURING
DEMOLITION.
17. DISCONNECT AND REMOVE ALL EXISTING LIGHTING FIXTURES, OUTLETS, WIRING,
OUTLET BOXES, EQUIPMENT AND DEVICES THAT ARE MADE OBSOLETE BY NEW
CONSTRUCTION.
3
Revisions:
18. GC SHALL PATCH ALL SURFACES DISTURBED BY REMOVALS OF EXISTING
CONSTRUCTION OR INSTALLATION OF NEW WORK.
19. ALL MATERIALS AND EQUIPMENT SHALL BE REMOVED IN STRICT ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS.
04
20. PATCHING SHALL MATCH EXISTING ADJACENT FINISHES, MATERIALS, ETC.
21. GC SHALL SHALL NOT LEAVE ANY REMAINING CONSTRUCTION UNSUPPORTED. SECURE,
SUSPEND AND/OR ANCHOR ANY EXISTING CONSTRUCTION AS REQUIRED. DO NOT HANG
FROM ROOF DECK
08
22. PATCH ANY EXISTING HOLES IN ROOF CONSTRUCTION, COORDINATE ALL ROOF WITH
WITH LANDLORD /VERIFY IN FIELD/.
16
23. IF NOT EXISTING, RUN DRYWALL AND SEAL TO DECK IF NECESSARY ON DEMISING WALLS
AND SOFFITS TO DECK
2
24. EXISTING DATA SERVICE AND EQUIPMENT TO REMAIN, COORDINATE WITH LOCAL
TELECOM COMPANY. DO NOT REMOVE PHONE SERVICE. COMPANY PROPERTY. IF
RELOCATION IS NECESSARY GC MUST COORDINATE WITH WARNER TELECOM PRIOR TO
REMOVAL/RELOCATION. GC IS RESPONSIBLE FOR COORDINATION OF WORK WITH
PHONE COMPANY. GC MUST REVIEW SCOPE OF WORK WITH LOCAL TELECOM CO. AND
PHONE TECHNICIAN WHILE TECH IS ON SITE. GC IS RESPONSIBLE FOR ANY DAMAGE OR
LOSS OF DATA/PHONE EQUIPMENT AND SERVICES.
11
11
25. ALL DOOR HARDWARE MUST BE REPLACE AS SPECIFIED ON SHEET AII0
26. IT IS THE TENANTS INTENT TO REUSE ANY EXISTING DUCTWORK WHERE POSSIBLE.
COORDINATE EXISTING DUCTWORK WITH MECHANICAL PLANS FOR POSSIBLE REUSE
PRIOR TO REMOVAL. CONTACT RUE2I REGIONAL DIRECTOR OF CONSTRUCTION FOR ANY
INQUIRIES.
16
No.
Description
Project No.:
Drawn By:
Reviewed By:
12
12
15
12
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
SITE SPECIFIC DEMOLITION NOTES:
Filename:
A. EXISTING UNITS TO BE REPLACED. EXISTING HVAC, DUCTWORK AND DISTRIBUTION TO
REMAIN TO GREATEST EXTENT POSSIBLE.
1
B. GC TO REMOVE ALL EXISTING CEILINGS GRID/TILE COMPLETE, UNO. GC TO EVALUATE
EXISTING CONDITIONS AND DETERMINE HIGHEST POSSIBLE MOUNTING HEIGHT FOR NEW
LIGHTING SYSTEM. REPORT FINDINGS TO RUE21 REGIONAL DIRECTOR OF CONSTRUCTION
TO DETERMINE APPROPRIATE FINAL HEIGHT.
11
16
D. REMOVE ALL EXISTING LIGHTING COMPLETE, UNLESS NOTED OTHERWISE.
E. RECONFIGURE AND RELOCATE EXISTING HEADS OF SPRINKLER SYSTEM AS REQUIRED
FOR NEW LAYOUT AND PROPER COVERAGE AS REQUIRED BY LOCAL ENFORCEMENT.
SPRINKLER VENDOR TO PROVIDE DETAILS DRAWINGS TO LOCAL MUNICIPALITY AND
LANDLORD'S INSURANCE UNDERWRITER FOR REVIEW AND APPROVAL.
11
DEMO
FLOOR PLAN
C. REMOVE EXISTING CEILING(S), SOFFITS, BULKHEADS AND RELATED CEILING SUPPORT
STRUCTURE COMPLETE, UNO.
N
16
Sheet Title:
DEMO FLOOR PLAN
SCALE
1/4" = 1' - 0"
1
GENERAL NOTES
SCALE
-
Sheet #:
D-101
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
A
B
C
10
7
TOILET
ROOM
-
07
SD
C
(E OL.
)
MS
08
REMOVE ALL EXISTING LIGHTING COMPLETE, UNLESS NOTED OTHERWISE.
SEE ELECTRICAL DRAWINGS
03
REMOVE EXISTING CEILING(S);, SOFFITS, MOTION SENSORS, SMOKE
DETECTORS, SPEAKERS, OTHER EQUIPMENT U.N.O,BULKHEADS AND RELATED
CEILING SUPPORT STRUCTURE COMPLETE, UNO.
04
EXISTING STRUCTURAL COLUMN TO REMAIN. REMOVE EXISTING COLUMN
ENCLOSURE COMPLETE. VERIFY EXISTING CONDITION BEHIND COLUMN WRAP
(I.E. ROOF DRAINS/ AND REPORT FINDINGS TO REU2I PRIOR TO DEMOLITION.
CLEAN/SAND COLUMNS SMOOTH AND PREP TO RECEIVE NEW FINISHES.
05
REMOVE EXISTING SIGN(S). PATCH/REPAIR/REFINISH EXISTING STOREFRONT
SIGN FACADE FOLLOWING DEMOLITION OF EXISTING SIGN(S). PREPARE TO
RECEIVE NEW FINISHES TO MATCH EXISTING.
06
REPLACE ALL EXISTING HVAC DIFFUSER, UNLESS NOTED OTHERWISE.
SEE MECHANICAL DRAWINGS
07
REMOVED EXISTING ACCESS LADDER
08
EXISTING CEILING MOUNTED OUTLET, CAP OFF TO NEAREST J-BOX
09
EXISTING ROOF LINE
10
EXISTING TRELLIS, TO REMAIN
Seal:
A Project for:
6
03
06
06
04
STAFF
AREA
-
5
TENANT IMPROVEMENT
05
SD
MS
KEYNOTES
SCALE
-
-
03
1.
DO NOT SCALE DRAWINGS.
2.
THE GC SHALL BE RESPONSIBLE FOR ALL DEMOLITION DESCRIBED ON THESE
DRAWINGS AND ANY OTHER DEMOLITION THAT MAY BE DIRECTED, IN WRITING BY THE
ARCHITECT, NOT SPECIFICALLY NOTED ON THESE DRAWINGS.
3.
THE GC SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES REQUIRED
FOR COMPLETE INTERIOR DEMOLITION REMOVALS AND RELATED WORK AS INDICATED
AND SPECIFIED HEREIN, AND AS REASONABLY IMPLIED TO COMPLETE THE WORK IN ALL
RESPECTS.
4.
THE GC SHALL REPAIR AT THEIR OWN EXPENSE ANY DAMAGE DONE TO THE OWNERS
PROPERTY, AND ANY OTHER PERSON OR PERSONS ON OR OFF THE PREMISES AS A
RESULT OF THE GC'S WORK DEFINED HEREIN.
5.
SALVAGE: REMOVE, REPAIR, CLEAN < STORE REMOVED ITEMS AS MAY BE DIRECTED
FOR RE-USE BY THE ARCHITECT AND/OR OWNER
6.
REFER TO MECHANICAL, ELECTRICAL, PLUMBING, AND/OR SPRINKLER DRAWINGS FOR
ANY ADDITIONAL DEMOLITION NOTES.
7.
REMOVE ALL ABANDONED MATERIALS, DEVICES, FIXTURES, PIPES, CONDUITS, WIRES,
ETC. FROM PREMISES INCLUDING THE AREA OF THE CEILING PLENUM AND CONNECTION
POINTS OUTSIDE OF THE TENANT SPACE. RETURN THE TENANT SPACE TO BASE
BUILDING CONDITIONS.
8.
H GC TO VISIT SITE PRIOR TO START OF WORK TO DETERMINE EXTENT OF DEMOLITION
REQUIRED TO PROCEED WITH INSTALLATION OF THIS PROJECT AS NOTED. IF ANY
DISCREPANCIES OCCUR, OR POTENTIAL CONFLICTS, CONTACT ARCHITECT AND RUE2I
PROJECT MANAGER
9.
MAINTAIN ALL FIRE RATINGS AS REQUIRED BY LOCAL CODES, LANDLORD AND FIRE
AUTHORITIES. IF EXISTING, REPAIR ANY FIRE PROOFING ON EXISTING STRUCTURAL
STEEL MEMBERS WHETHER IT BE SPRAY-ON OR OTHER AFTER DEMOLITION.
05
ST
C
(E OL.
)
SALES
AREA
-
4
SD
04
02
03
06
SD
03
10. COORDINATE THE MOVEMENT OF CONSTRUCTION MATERIALS AND EQUIPMENT, TRASH
REMOVAL, TEMPORARY ELECTRIC WITH THE LANDLORD.
SD
11. DISCONNECT AND REMOVE ALL EXISTING LIGHTING FIXTURES, OUTLETS, WIRING,
OUTLET BOXES, EQUIPMENT AND DEVICES THAT ARE MADE OBSOLETE BY NEW
CONSTRUCTION.
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
12. GC SHALL PATCH ALL SURFACES DISTURBED BY REMOVALS OF EXISTING
CONSTRUCTION OR INSTALLATION OF NEW WORK.
3
13. ALL MATERIALS AND EQUIPMENT SHALL BE REMOVED IN STRICT ACCORDANCE WITH
MANUF. RECOMMENDATIONS.
2580 BELL ROAD
AUBURN, CA 95603
02
03
02
01
SD
02
EXISTING EXTERIOR LIGHT FIXTURE TO REMAIN. CLEAN AND RE-LAMP
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
TOILET
ROOM
-
01
Revisions:
14. PATCHING SHALL MATCH EXISTING ADJACENT FINISHES, MATERIALS, ETC.
15. GC SHALL SHALL NOT LEAVE ANY REMAINING CONSTRUCTION UNSUPPORTED. SECURE,
SUSPEND AND/OR ANCHOR ANY EXISTING CONSTRUCTION AS REQUIRED. DO NOT HANG
FROM ROOF DECK.
SD
08
MS
16. EXISTING DATA SERVICE AND EQUIPMENT TO REMAIN, COORDINATE WITH WARNER
TELECOM. DO NOT REMOVE PHONE SERVICE. COMPANY PROPERTY. IF RELOCATION IS
NECESSARY GC MUST COORDINATE WITH WARNER TELECOM PRIOR TO
REMOVAL/RELOCATION. GC IS RESPONSIBLE FOR COORDINATION OF WORK WITH
PHONE COMPANY. GC MUST REVIEW SCOPE OF WORK WITH WARNER TELECOM AND
PHONE TECHNICIAN WHILE TECH IS ON SITE. GC IS RESPONSIBLE FOR ANY DAMAGE OR
LOSS OF DATA/PHONE EQUIPMENT AND SERVICES.
04
2
SD
17. IT IS THE TENANTS INTENT TO REUSE ANY EXISTING DUCTWORK WHERE POSSIBLE.
COORDINATE EXISTING DUCTWORK WITH MECHANICAL PLANS FOR POSSIBLE REUSE
PRIOR TO REMOVAL. CONTACT RUE2I REGIONAL DIRECTOR OF CONSTRUCTION FOR ANY
INQUIRIES.
05
SD
05
02
03
06
18. T RECONFIGURE AND RELOCATE EXISTING HEADS OF SPRINKLER SYSTEM AS REQUIRED
FOR NEW LAYOUT AND PROPER COVERAGE AS REQUIRED BY LOCAL ENFORCEMENT.
SPRINKLER VENDOR TO PROVIDE DETAILS DRAWINGS TO LOCAL MUNICIPALITY AND
LANDLORD'S INSURANCE UNDERWRITER FOR REVIEW AND APPROVAL.
Description
Project No.:
01
05
No.
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
05
08
03-11-15
Date:
Filename:
Sheet Title:
1
DEMOLITION
CEILING PLAN
N
10
Sheet #:
D-201
DEMOLITION CEILING PLAN
SCALE
1/4" = 1' - 0"
1
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
A
B
12'-0" WS-1
9"
1'-2"
C
10'-0" WS-1
10'-0" WS-1
12'-0" WS-1
01
MUSIC SYSTEM INSIDE DATA CABINET
02
MUSIC AMPLIFIER ON TOP OF DATA CABINET
03
LINE OF ROOF
7
KEYNOTES
TOILET
ROOM
202
TOILET
ROOM
203
SCALE
-
-
FIXTURE LEGEND
Seal:
REFER TO FIXTURE INSTALLATION GUIDE FROM MILLWORK VENDOR FOR MORE INFORMATION
A-401
RUE +
11"
A
5"
C
(E OL.
)
EXIT
CORRIDOR
200
3
A-402
2
6
A-402
2'-7"
A
6
A
A-401
4'-0" WS-1
12'-0" WS-1
4'-0" WS-1
12'-0" WS-1
02
B
2
A-402
CH
COAT HOOK - PROVIDE BLOCKING AS REQUIRED. REFER TO INSTALLATION GUIDE FOR BLOCKING
LOCATION
CW
CASHWRAP - (2) STRAIGHT FRONT CASHWRAPS, SEE 4/A-403.
DC
DATA CABINET
ER
EQUIPMENT RACK
FM
ANTI-FATIGUE MAT
FT
FOLDING TABLE
GB
HANDICAP FITTING ROOM GRAB BAR. PROVIDE BLOCKING AS REQUIRED. REFER TO
INSTALLATION GUIDE FOR BLOCKING LOCATION. 48" GRAB BAR, BOBRICK - B - 5806X48.
12'-0" WS-1
MC
MICROWAVE
PH
POSTER HOLDER
PT
PROCESSING TABLE
R
REFRIGERATOR
RETRIEVER HOOK - MOUNTED AT 90" TO CENTER AFF WITH FASTENAL WALL TOGGLE 50955
RESTROOM SHELVING. REFER TO A10 FOR INFORMATION
SP
FALCON SYSTEM CLEAR ACRYLIC SECURITY PEDESTALS. 6'-0" SYSTEM
ST*
GUYS SAWTOOTH DISPLAY WITH ILLUMINATED SIGN
SW1*
SLATWALL 1 - BLACK
SW2*
SLATWALL 2 - FROSTY WHITE
2
SW3*
SLATWALL 3 - DROPS SILVER
A-201
WS-1*
WALL STANDARDS - WHITE WALL STANDARDS, PAINT SCREW HEADS WHITE.
WS-2*
WALL STANDARDS - BLACK WALL STANDARDS
5
A-401
JUNIORS
4
A-401
* ITEM NOTED ON PLAN IN DIMENSION STRINGS
10'-0" WS-1
2'-9"
SAFE
SH
12'-0" WS-1
C
A
A Project for:
MIRROR W/ 1/4" ALUMINUM J MOLD/CHANNEL AT TOP AND BOTTOM OF MIRROR ACROSS ENTIRE
WIDTH. APPLY DAP CLEAR CAULK AT ALL EXPOSED EDGES. REFER TO SHEET A-401/A-402 FOR
SIZES AND LOCATION
S
STOCK
201
FIXTURE LEGEND
SCALE
-
12'-0" WS-1
B
12'-0" WS-1
3
STORE
CHARACTERISTICS:
THIS STORE:
rue+ 70x100 PROTO v7.1:
TYP.
SALES AREA:
JUNIORS (SF)
TAREA (SF)
rue PLUS (SF)
GUYS (SF)
ETC! (SF)
FITTING (SF)
STOCK/CORRIDOR/RRs (SF)
TOTAL AREA (SF)
2793 SF (41%)
154 SF (2%)
1220 SF (18%)
1034 SF (15%)
779 SF (12%)
229 SF (3%)
591 SF (9%)
6800 SF (100%)
2421 SF (35%)
154 SF (2%)
1500 SF (21%)
1074 SF (15%)
880 SF (13%)
265 SF (4%)
706 SF (10%)
7000 SF (100%)
JUNIORS STANDARDS (LF)
TAREA STANDARDS (LF)
rue PLUS STANDARDS (LF)
GUYS STANDARDS (LF)
GUYS ACCESSORIES (LF)
ETC SLATWALL (LF)
110 LF
8 LF
90 LF
68 LF
13 LF
69 LF
126 LF
8 LF
114 LF
76 LF
12 LF
81 LF
4
A-402
A
C
(E OL.
)
3
A-401
A
4
4'-5"
B
SALES AREA
100
A-402
1'-0"
A
A-401
3'-0"
D
1
2
AUBURN, CA (STRIP)
VERSION 3.3 02-04-15
3'-0"
10'-0" WS-1
4
A-402
-
A-402
C
B
ACCESSIBLE FITTING ROOM BENCH (24"W x 48"L x 18"H)
RH
2
TAREA
B2
M
12'-0" WS-1
16'-0" WS-2
01
FITTING ROOM BENCH
4'-4"
17'-7" SW1
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
4
C
2
A-401
10'-0" WS-1
17'-6" SW2
A-403
B
2580 BELL ROAD
AUBURN, CA 95603
5
B1
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
10'-0" WS-1
A
TENANT IMPROVEMENT
8'-0" WS-1
FIXTURE TAG DESCRIPTION
A
C
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
3
A-402
3
ETC
Revisions:
2
A-201
A
D
A-402
6"
6"
C
18'-9" SW2
7'-6"
3
A-403
B
4'-0" WS-2
D
8
2'-0"
SW1
23'-3"
B
C
4'-6" SW1
A
7
A-402
9
A-402
A-402
C
B
4'-0"
WS-1
B
15
A-503
FITTING
AREA
101
D
C
B
C
1
A-403
C
B
ADA
FITTING
4'-0"
WS-1
D
1
GUYS
A-401
A
A
D
6
A-402
2.
REFER TO SHEET G-102 FOR RESPONSIBILITIES.
3.
WALL FINISHES TO BE INSTALLED PRIOR TO WALL FIXTURE INSTALLATION.
4.
PRIOR TO FIXTURE INSTALLATION, REFER TO THE FIXTURE HANDBOOK FOR INFORMATION
ON ASSEMBLY AND INSTALLATION OF THE FIXTURES. IF THE HANDBOOK IS NOT AVAILABLE,
CALL RUE21 REGIONAL DIRECTOR OF CONSTRUCTION (SEE COVER SHEET) FOR A
REPLACEMENT.
5.
SLATWALL FIXTURE TO BE GLUED (USING LIQUID NAILS) AND SCREWED INTO EVERY STUD
EVERY 12" IN SLAT RECESS. SCREW IN PRIOR TO INSTALLING PLASTIC COVER. PAINT ANY
EXPOSED SCREW HEADS AS REQUIRED. SEE INSTALLATION GUIDE FOR MORE
INFORMATION.
6.
WALL STANDARDS TO BE MOUNTED AT EVERY 24" OC. CENTER BETWEEN ADJACENT WALLS,
UNO. MOUNT AT 12" AFF TO BOTTOM, TOP TO 11'-0" AFF. INSTALL WITH TOGGLE 50955 AND
SCREWS 0149015 BY FASTENAL. ALL MOUNTING HARDWARE BY GC INSTALL (1)
TOGGLE/SCREW IN EVERY HOLE IN EACH WALL STANDARD (12 TOTAL) AND USE SCREWS
WITH FLAT HEAD (NOT ROUNDED).
1
A-401
3
A-402
10'-0" WS-1
D
D
D
13'-612"
A
5
DO NOT SCALE DRAWINGS.
2
12'-0" WS-1
A
1.
7.
A
B
8.
C
ALIGN
9.
WHERE WALL STANDARDS ARE TO BE INSTALLED ON A MASONRY WALL; PROVIDE (4) 1X4
FIRE RATED HORIZONTAL WOOD STRAPPING. RUN AT 12'-0" AFF, 10'-0" AFF, 8'-0"AFF, AND 3'-0"
AFF. SECURE WITH 2" TAPCONS AT 24" OC USE 2" TAPCONS FOR STANDARDS.
CLEAR CAULK EDGES OF ALL FITTING ROOM FIXTURES INCLUDING BUT NOT LIMITED TO
BENCH, COAT HOOK, BASE, TRI, ETC.
No.
Description
Project No.:
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
REFER TO 2/A2 FOR ADDITIONAL BACK OF HOUSE EQUIPMENT.
Sheet Title:
10. PROVIDE AND INSTALL ALL ADA COMPLIANT IDENTIFICATION /TACTILE SIGN(S) AT ALL EXITS,
HANDICAPPED FITTING ROOMS, AND TOILET ROOMS IN COMPLIANCE WITH IBC 1011.3 AND
ICC ANSI A117.1.
1
PROPOSED
FIXTURE & EQUIPMENT
PLAN
11.
10'-0" WS-1
3'-212" ST
8'-1112" SW1
14'-0" WS-1
SALES AND FITTING AREA. WALL PROTEX OR EQUAL. DO NOT INSTALL ON WOOD END CAPS.
14'-0" WS-1
12. REFER TO FIXTURE INSTALLATION GUIDE PROVIDED BY MILLWORK VENDOR FOR COMPLETE
SPECIFICATIONS AND INSTALLATION GUIDE FOR FITTING ROOM ELEMENTS.
N
Sheet #:
PROPOSED EQUIPMENT & FIXTURE PLAN
SCALE
1/4" = 1' - 0"
1
GENERAL NOTES
SCALE
-
A-102
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
A
B
12'-2" WC-1
C
5'-8" PT-9
16'-0" WF-7
PROVIDED/INSTALLED BY
TENANT SIGN VENDOR
10'-2" PT-2
7
10'-4" WC-1
A
5
A-402
6
4'-6" WC-1
12'-2" WC-1
2
PT-9
9
12
2
PT-4
3'-8"
12'-4" WC-1
B
5'-0"
10'-5" PT-2
3
C
DESCRIPTION
GR-1
WALL GRAPHIC
TENANT VENDOR
GR-2
WALL GRAPHIC
TENANT VENDOR
GR-3
WALL GRAPHIC
TENANT VENDOR
GR-4
WALL GRAPHIC
TENANT VENDOR
GR-5
WALL GRAPHIC
TENANT VENDOR
GR-6
WALL GRAPHIC
TENANT VENDOR
PT-1
PAINT
BENJAMIN MOORE
DOVE WING (LIGHT GRAY)
PT-2
PAINT
BENJAMIN MOORE
SNOW WHITE (WHITE)
PT-3
PAINT
BENJAMIN MOORE
KENDALL CHARCOAL (DARK GRAY)
A-402
PT-4
PAINT
SHERWIN WILLIAMS
FUSION (GREEN)
A
PT-5
PAINT
SHERWIN WILLIAMS
FORSYTHIA (YELLOW)
PT-6
PAINT
TUTTI FRUTTI (PINK)
PT-7
PAINT
GLIDDEN
PROFESSIONAL
BENJAMIN MOORE
BLACK
PT-8
PAINT
BENJAMIN MOORE
BABY FAWN (MEDIUM GRAY)
PT-9
PAINT
SHERWIN WILLIAMS
TEMPO TEAL (TEAL)
RUE+ ONLY
WC-1 WALL COVERING
RJF/KOROSEAL
RJF9565 - SILVER
CUSTOM VINYL WALLCOVERING. TYPE
2 - CLASS A FIRE RATING
WD-1 WOOD END CAP
TIMELINE
WD-2 WOOD END CAP
TIMELINE
WD-3 WOOD END CAP
TIMELINE
WD-4 WOOD END CAP
TIMELINE
WF-1
TENANT VENDOR
12'-4" GR-1 TO 11'-0" AFF
12'-4" PT-2
3
A-402
4
PT-4
9
C
(E OL.
)
WD-1
SALES AREA
100
4
9
B
PT-4
4
6'-0" WF-1
IN TRANSOM ABOVE
80'-0" PT-2
CF-1
2
A-401
1
A-402
A
TYPICAL
THIS PARTITION
WF-2WINDOW FILM
WF-6
NOT USED
WF-7
TENANT VENDOR
2
10'-4" PT-2
A-401
ETC
10'-4" GR-1 TO 11'-0" AFF
A-403
A
WINDOW FILM
C
7
A-402
B
2
4'-0" PT-3
B
8
2
D
GR-4
C
5
A-402
PT-4
C
A
D
1
A-403
C
PT-2
B
4'-2" PT-2
8
PT-3
8
GR-2
PT-2
Revisions:
FINISH SCHEDULE
SCALE
-
-
WD-3
WD-3
PT-5
WD-3
TO DECK
1.
DO NOT SCALE DRAWINGS.
2.
REFER TO SHEET G-102 FOR RESPONSIBILITIES.
3.
REFER TO SHEET G-102 FOR FINISH LEGEND AND SPECIFICATIONS.
4.
5.
REFER TO ELEVATIONS ON SHEET A-401/A-402 FOR ADDITIONAL FINISH INFORMATION.
DIMENSIONS ON PLANS MAY NOT REPRESENT FIELD CONDITIONS, IT IS REQUIRED THAT TENANT VENDOR VERIFY
ALL GRAPHIC LENGTHS WITH GC PRIOR TO ORDERING GRAPHICS. INCLUDE ADDITIONAL 6" MINIMUM TO TOTAL
GRAPHIC LENGTH.
6.
ALL WALLS TO BE PRIMED FROM FINISH FLOOR TO CEILING/DECK.
7.
ALL CEILINGS AND SOFFITS TO BE PAINTED PT-1, UNO.
8.
SALES AND FITTING AREA DECK AND ALL EXPOSED ELEMENTS (INCLUDING BUT NOT LIMITED TO; DUCTWORK,
STRUCTURE, CONDUIT, PIPES, ALL-THREAD, UNISTRUT, HANGARS, ETC) TO BE PAINTED PT-1.
9.
ALL EXPOSED COLUMNS IN SALES AND FITTING AREA TO BE PAINTED PT-3, UNO.
2
13
3
D
1
A-402
A-401
PT-5
9
3
C
TYPICAL
THIS
PARTITION
2
B
1
6
A-402
B
7
GUYS
TYPICAL
THIS
PARTITION
A-401
A
PT-5
PT-5
TYPICAL
11. ALL SALES AREA WALLS TO RECEIVE WT-1 AS SHOWN DASHED ON 1/A121. GC TO PATCH, REPAIR AND PAINT TRIM
PT-8 AFTER INSTALLATION. REFER TO ELEVATIONS ON A6 FOR FURTHER CLARIFICATION.
14'-4" PT-2
WD-4
PT-5
Description
Project No.:
Drawn By:
A-503
WD-4
No.
10. WALL COVERING AND GRAPHICS TO BE INSTALLED FROM FINISHED FLOOR TO BOTTOM OF WT-1, UNO. ALL WALLS
TO BE PAINTED PT-1 ABOVE WT-1 TO DECK,UNO. REFER TO IS1 FOR TRIM HEIGHT.
17
14'-4" WC-1
A
PT-3
D
GR-3
Client:
12'-6" WC-1
PT-3
8
ADA
FITTING
PT-2
B
FITTING
AREA PT-5
101
B
GC TO PAINT BACKSIDE PT-7 (BLACK)
2
7
D
4'-2" WC-1
A
GC TO PAINT BACKSIDE PT-7 (BLACK)
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
PT-3
2
PT-3
PT-3
A-402
2
5
FITTING AREA
CF-1
WB-1A
GC TO PAINT BACKSIDE PT-2 (WHITE)
A-402
GR-5
GR-6
GC TO PAINT BACKSIDE PT-2 (WHITE)
3
WD-1
TO DECK
PT-2
PT-3
9
3
A-403
TYPICAL
7
C
D
TYPICAL
THIS PARTITION
16
A-503
3'-6" PT-5
8
WHITE WHITE PINE; 5-1/2" WIDE.
SQUARE EDGE.
WHITE WHITE PINE; CUSTOM 7-1/2"
WIDE. SQUARE EDGE.
BLACK BLACK PINE; 5-1/2" WIDE.
SQUARE EDGE.
BLACK BLACK PINE; CUSTOM 7-1/2"
WIDE. SQUARE EDGE.
CUSTOM STREET MAP GRAPHIC ON
CLEAR FILM
13
C
A
D
7
BLACK SCHEME FOR ACCESSORY
FIXTURES*
BLACK SCHEME FOR ACCESSORY
SKATER FITTING ROOM SCHEME
FIXTURES*
RUNWAY MODEL FITTING ROOM
GRAY SCHEME FOR ACCESSORY
SCHEME
FIXTURES*
BLACK SCHEME FOR ACCESSORY
ROCK STAR FITTING ROOM SCHEME
FIXTURES*
WHITE SCHEME FOR ACCESSORY
PRINCESS FITTING ROOM SCHEME
FIXTURES*
CLUB 21 FITTING ROOM SCHEME
3
A
A-402
LOFT GRAPHIC
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
A-201
D
NOTES
4
C
B
WINDOW FILM
PRODUCT DESCRIPTION
CUSTOM LOFT GRAPHIC WITH
APPLIED ON EXTERIOR OF
LARGE RUE21 TEXT
GLAZING
* FITTING ROOM ACCESSORY FIXTURES (TRIM, DOOR, HOOK BOARD, BENCH) COLOR SCHEME AS NOTED IN
CORRESPONDING GRAPHIC'S NOTE SECTION. INSTALLATION DETAILS AND INSTRUCTIONS PROVIDED BY MILLWORK VENDOR.
3
WD-1
TYPICAL
THIS
PARTITION
MANUFACTURER
A-402
SALES
AREA
CF-1
WB-1
3
-
LABEL
11
TYPICAL
THIS
PARTITION
D
SCALE
REFER TO IS1 FOR ALL FINISHES AND SPECIFICATIONS
WD-1
A
CONTINUOUS (17'-1") LOFT GRAPHIC TO BE DIVIDED AS DIMENSIONED AND INSTALLED
ON FLOATING WALLS. SEE A6 FOR LAYOUT.
2
A-401
A-401
3
13
ABBREVIATED FINISH LEGEND
A-201
A-401
PAINT WALLS PT-9 (TEAL) FROM WT-1 TO DECK ABOVE.
5
PT-4
B
12
WD-1
TO DECK
WD-2
4
A
CONTINUOUS (19'-1") LOFT GRAPHIC TO BE DIVIDED AS DIMENSIONED AND INSTALLED
ON FLOATING WALLS. SEE A6 FOR LAYOUT
-
2
TYPICAL
THIS
PARTITION
11
KEYNOTES
WD-1
TAREA
FLOOR TAPING/STRIPING. U-LINE #S-383. 2"X36 YARDS. YELLOW/BLACK HEAVY DUTY
VINYL SAFETY TAPE.
PT-4
PT-4
C
10
2
B
2
VINYL GRAPHICS PROVIDED AND INSTALLED BY TENANT SIGN VENDOR.
A-402
WD-2
PT-4
13'-6" WC-1
9
12'-4" PT-2
JUNIORS
4'-3"
2
PT-4
PT-4
PRIME WALLS
ONLY TO 12'-0"
AFF, DO NOT
PAINT.
PT-9
4
PT-4
A-401
2
PT-9
TO DECK
STOCK
201
AREA BETWEEN WT-1 AND WT-2 TO BE PAINTED NOTED PAINT COLOR. REFER TO
ELEVATIONS FOR FURTHER CLARIFICATION.
11
WD-1
TO DECK
12'-4" PT-2
4'-6" WC-1
PT-9
3'-0"
6
8
3
A
WD-1
WD-2
12'-4" WC-1
WD-1
A
PAINT WALLS PT-6 (PINK) FROM WT-1 TO DECK ABOVE.
L.
C
O
WD-1
TO DECK
10
CF-2
WB-1
6
SLATWALL DISPLAY TO 11'-0" AFF, REFER TO SHEET A2 FOR LOCATIONS.
PT-9
A
5'-6"
PAINT WALLS PT-5 (YELLOW) FROM WT-1 TO DECK ABOVE.
9
2
CF-2
3'-0"
5
A Project for:
)
(E
A-402
TYPICAL
PAINT WALLS PT-4 (GREEN) FROM WT-1 TO DECK ABOVE.
2580 BELL ROAD
AUBURN, CA 95603
1
4'-7" PT-9
CF-1
4
7
12'-4" PT-2
21
A-503
CF-2
WB-1
PAINT WALLS PT-3 (DARK GRAY) FROM WT-1 TO DECK ABOVE.
Seal:
RUE +
EXIT
CORRIDOR
200
3
PT-3
WD-2
WD-2
A-401
21
A-503
PAINT WALLS PT-1 (LIGHT GRAY) FROM WT-1 TO DECK ABOVE.
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
1
2
TENANT IMPROVEMENT
1
PT-3
TYPICAL
THIS
PARTITION
PT-9
ALL EXPOSED WALL SURFACES TO BE PAINTED PT-2 UNO.
PT-9
10'-9" WC-1
VT-1
WB-2
WP-1
2
CF-1
8'-7" PT-2
VT-1
WB-2
WP-1
PT-9
PT-9
6'-9" GR-1 TO 11'-0" AFF
TOILET
ROOM
202
TOILET
ROOM
203
1
12. ALL FITTING AREA WALLS TO RECEIVE WT-1. WALL TYPE D TO RECEIVE WT-2. GC TO PATCH, REPAIR AND PAINT TRIM
PT-8 AFTER INSTALLATION.
PT-3
PT-5
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
13. WHERE EXISTING FINISHES TO REMAIN, CLEAN/REPAIR AS REQUIRED TO LIKE NEW CONDITION.
Sheet Title:
C
10'-4" PT-2
ALIGN
3'-212" PT-3
ABOVE ST
14. WALL FINISHES ARE TO BE INSTALLED PRIOR TO INSTALLATION OF WALL STANDARDS. WHERE FINISHES MEET,
ALIGN WITH CENTERLINE OF WALL STANDARD.
1
PROPOSED
FINISH FLOOR
PLAN
15. REFER TO DETAILS 14/A-503 THROUGH 20/A-503 FOR WOOD END CAP INSTALLATION DETAILS.
16'-0" WF-7
PROVIDED/INSTALLED BY
TENANT SIGN VENDOR
N
Sheet #:
FINISH FLOOR PLAN
SCALE
1/4" = 1' - 0"
1
GENERAL NOTES
SCALE
-
A-103
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
C
16
01
WHERE SHOWN ANGLED ON PLAN
02
FABRIC TUBE SUSPENDED CEILING ELEMENT - SEE DETAILS 21/A-503 & 1/A-502.
RUE21 REGIONAL CONSTRUCTION DIRECTOR TO GIVE DIRECTION ON FINAL
PLACEMENT AT PUNCH LIST.
03
LAMPSHADE FIXTURE SUSPENDED CEILING ELEMENT - SEE DETAILS 11/A-502.
RUE21 REGIONAL CONSTRUCTION DIRECTOR TO GIVE DIRECTION ON FINAL
PLACEMENT AT PUNCH LIST.
04
ETC! EXCLAMATION POINT SUSPENDED CEILING ELEMENT - SEE DETAILS 3/A-502
RUE21 REGIONAL CONSTRUCTION DIRECTOR TO GIVE DIRECTION ON FINAL
PLACEMENT AT PUNCH LIST.
05
SILVER METALLIC FLEXIBLE MESH SUSPENDED CEILING ELEMENT. SUSPEND
FROM CONDUIT, PROVIDED BY TENANT VENDOR AND INSTALLED BY GC. GC TO
PROVIDE MOUNTING HARDWARE AS REQUIRED. SEE DETAIL 3/A-403.
06
GREEN APPLE PANELS FLEXIBLE MESH SUSPENDED CEILING ELEMENT.
SUSPEND FROM CONDUIT, PROVIDED BY TENANT VENDOR AND INSTALLED BY
GC. GC TO PROVIDE MOUNTING HARDWARE AS REQUIRED. SEE DETAIL 3/A-403
17
CLNG HT 8'-0"
Cx6
Cx6
14
8"
17
A
A
10'-91
A
10'-91
2"
2"
08
A
10'-91
17
C
2"
RUE +
SECURITY DOME(S) CEILING ELEMENT - SEE DETAIL 10/A-502. NOTIFY RUE21
REGIONAL DIRECTOR OF CONSTRUCTION IF DOMES WILL NOT BE VISIBLE ONCE
INSTALLED.
09
SPIDER TRACK - SEE DETAIL 20/A-502. MUST BE MOUNTED AT, OR ABOVE TOP OF
STOREFRONT.
10
TENANT ILLUMINATED SIGN(S) - PROVIDE BLOCKING AND AS REQUIRED FOR
INSTALLATION OF SIGN(S). PROVIDE POWER ON TIME CLOCK CIRCUIT, SEE
ELECTRICAL DRAWINGS. - UNDER A SEPARATE PERMIT
11
8' HANGING ROD AT 10'-0" AFF - SEE DETAIL 15/A-502
12
ACCESS PANEL - 24" X 24" MINIMUM, TO PROVIDE ACCESS TO HOT WATER
HEATER IN WALL ABOVE RESTROOM. FLUSH MOUNTED, ADJUST SIZE AS
REQUIRED FOR POTENTIAL REPLACEMENT OF HOT WATER HEATER. PAINT PT-2.
13
WIFI CEILING ELEMENT MOUNT LOCATION. SEE DETAIL 13/A-502
14
WATER HEATER ABOVE CEILING, SEE PLUMBING DWGS FOR MORE INFORMATION
15
ACCESS LADDER. REFER TO DETAIL 22 & 23/A-503
16
EXISTING TRELLIS
17
EXISTING ROOF LINE
C
8'-9"
01
02
C
C
(E OL.
)
EXIT
CORRIDOR
200
C
1'-6"
A Project for:
6
C
A
A
A
A
C
A
Cx7
C
09
Cx7
01
C
3'-5"
C
C
A
11
3'-212"
3'-1112"
7'-4"
C
01
C
OPEN TO DECK
STOCK
201
5
C
2'-6"
CLNG HT 14'-7"
A
SUSPENDED RIGID METAL GRID PANELS WITH NON-ILLUMINATED SIGNAGE ON
BOTH SIDES OF CENTER PANEL PROVIDED BY TENANT VENDOR. GC TO PROVIDE
ADDITIONAL MOUNTING HARDWARE PER MILLWORK VENDOR'S DRAWINGS.
REFER TO DRAWINGS FROM VENDOR FOR INSTALLATION GUIDE AND DETAILS.
08
TYPICAL
12
CLNG HT 8'-0"
A
10'-912"
07
A
A
JUNIORS
Seal:
A
C
C
C
15
C
01
A
C
11
A
1'-6"
2'-0"
A
KEYNOTES
C
SCALE
-
02
-
C
C
OPEN TO DECK
OPEN TO DECK
08
C
TYPICAL
01
A
A
A
A
C
01
A
C
TAREA
C
C
(E OL.
)
03
4'-0"
10
C
A
09
C
SALES AREA
100
A
01
4
10
C
A
A
A
CLNG HT 14'-7"
01
2580 BELL ROAD
AUBURN, CA 95603
Cx6
01
1'-0"
01
5'-11" TYPICAL
TOILET
ROOM
202
4'-6" TYPICAL
7
TOILET
ROOM
203
WALL TRIM (WT-1) SHOWN DASHED. SEE ELEVATIONS ON SHEET A6 AND A8 FOR
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
B
TENANT IMPROVEMENT
A
01
A
A
7'-312"
6'-1"
01
1'-0"
A
08
04
A
5'-4" TYPICAL
A
6'-1"
OPEN TO DECK
3'-212"
4"
3'-212"
2'-11"
4"
06
D
A
A
D
D
D
01
C
2.
DIMENSIONS ARE FROM FINISHED FACE OF DRYWALL TO FINISHED FACE OF DRYWALL
OR FACE OF CMU WALL, U.N.O. DO NOT SCALE DRAWINGS
C
3.
G.C SHALL FIELD VERIFY ALL DIMENSIONS AND JOB CONDITIONS AND SHALL REPORT
TO THE RUE2I REGIONAL DIRECTOR OF CONSTRUCTION ANY DISCREPANCIES AND/OR
OMISSIONS WHICH COULD INTERFERE WITH THE SATISFACTORY COMPLETION OF THE
WORK HEREIN.
4.
GC IS REQUIRED TO COMPLETE A SITE VISIT PRIOR TO ANY BID SUBMISSIONS FOR
RUE2I PROJECTS. NOTIFY RUE21 CONSTRUCTION DEPARTMENT OF SCOPE OMISSIONS
OR DISCREPANCIES.
01
C
E TR=10'
E
C
A
A
C
OPEN TO DECK
09
01
A
A
FITTING
AREA
101
A
7'-3" TYPICAL, UNO
A
08
7'-3" TYPICAL, UNO
TYPICAL
2
C
01
TR=8'
14'-51
01
A
A
GUYS
8.
ANY EXISTING DEMISING WALL/SOFFIT SHALL BE DRY WALLED TO DECK AND SEALED
WITH APPROPRIATE APPROVED SYSTEM AS REQUIRED TO MAINTAIN I HOUR FIRE
RATING PER UL 263.
9.
FIRE RATED WALLS AND ANY PENETRATIONS MUST COMPLY WITH THE UL DETAILS U263
AND W-L-1001.
10.
RECONFIGURE AND RELOCATE EXISTING HEADS OF SPRINKLER SYSTEM AS REQUIRED
FOR NEW LAYOUT AND PROPER COVERAGE AS REQUIRED BY LOCAL ENFORCEMENT.
SPRINKLER VENDOR TO PROVIDE DETAILS DRAWINGS TO LOCAL MUNICIPALITY AND
LANDLORD'S INSURANCE UNDERWRITER FOR REVIEW AND APPROVAL
11.
WHERE FURRING IS EXISTING TO REMAIN, GC IS TO ENSURE THAT THE PARTITION IS
CONSTRUCTED WITH A MINIMUM 2 1/52" STUD TO ENSURE THAT TENANT TOGGLE
SYSTEM CAN BE INSTALLED. IF THE EXISTING FURRING IS SMALLER THAT THE MINIMUM,
REPORT FINDINGS TO RUE2I REGIONAL DIRECTOR OF CONSTRUCTION.
12.
FIELD VERIFY ANY WALL PENETRATIONS INCLUDING BUT NOT LIMITED TO COLUMNS
AND RELATED ITEMS. REPORT ALL FINDINGS TO RUE2I CONSTRUCTION DEPARTMENT
PRIOR TO CONSTRUCTION. ANY ADDITIONAL COST ASSOCIATED WITH CHANGES
REQUIRED DUE TO FAILURE TO REPORT FINDINGS SHALL BE THE SOLE
RESPONSIBILITY OF THE GC.
13.
SEE SHEET A-503 FOR WALL TYPES AND DETAILS
14.
SEE SHEET A-501 FOR TYPICAL FRAMING / BACKING DETAILS
15.
SEE DETAILS 11/A-503, A-502 FOR TYPICAL WALL, CEILING
C
C
A
5'-9"
A
ALL METAL STUD PARTITIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.
C
E
Cx6
2"
TYPICAL, UNO
C
A
A
C
8"
01
5'-11" TYPICAL
ADA
FITTING
A
4'-212"
01
Cx8
4'-6" TYPICAL
Cx13
A
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
No.
17
Description
Project No.:
Drawn By:
4'-512"
2'-8"
17
7.
C
07
05
4'-10"
ALL WOOD, WOOD BLOCKING, AND/OR MDF OTHER THAN FINISHED WOOD TRIM SHALL
BE FIRE RETARDANT TREATED.
1'-0"
4'-10"
6.
C
C
2'-0"
GC SHALL VERIFY ALL FIELD CONDITIONS, LEASED SPACE DIMENSIONS, AND EXISTING
BUILDING ELEMENTS FOR COMPLIANCE WITH DRAWINGS BEFORE COMMENCING
CONSTRUCTION. GC SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR
HEIGHTS AND CONDITIONS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF RUE21 FOR RESOLUTION.
3
C
E
5.
C
1'-4" 1'-4"
13
REFER TO G-102 FOR RESPONSIBILITY SCHEDULE
C
TR=2'
Cx2
A
Client:
1.
C
2"
TR=10'
C
7'-31
ETC
TYPICAL, UNO
12'-2"
TYPICAL
A
09
14'-7" TYPICAL, UNO
A
A
TYPICAL, UNO
A
Reviewed By:
Cx8
Date
15.083.10
JA
RN
Scale:
01
03-11-15
Date:
Filename:
Sheet Title:
1
PROPOSED
REFLECTED CEILING
PLAN
OPEN TO DECK
N
17
16
NOTE:
REFER TO SHEET A-601 FOR LIGHT FIXTURE LEGEND AND
ELECTRICAL DRAWINGS FOR MORE INFORMATION
PROPOSED REFLECTED CEILING PLAN
Sheet #:
SCALE
1/4" = 1' - 0"
1
GENERAL NOTES
SCALE
-
A-121
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
A
B
C
R1
REMOVE EXISTING ATTIC ACCESS PANEL, IN IT'S ENTIRELY
R2
REMOVE EXISTING HVAC UNITS, IN IT'S ENTIRELY
R3
NEW ATTIC ACCESS PANEL, SEE DETAIL 23/A-503
R4
NEW HVAC UNITS (REFER TO MECHANICAL DRAWINGS) VERIFY IN FIELD THE
EXACT LOCATION
R5
EXISTING BUILT-UP ROOF
R6
EXISTING ROOF DRAIN AND OVER FLOW DRAIN SCUPPER
R7
EXISTING ROOF TILES
R8
EXISTING LINE OF BUILDING WALL BELOW
R9
EXISTING BUILT UP WOOD FRAMED CRICKET
R10
R8
7
1/4" PER
FT. MIN.
R7
Seal:
R10
EXISTING TRELLIS
R11
PATCH ROOF OPENINGS, SEE DETAIL 25/A-503 FOR MORE INFORMATION
R1
A Project for:
R4
R2
R11
R9
R5
R9
KEYNOTES
SCALE
-
-
R6
R6
CL
RIDGE LINE
3'-10"
V.I.F
TENANT IMPROVEMENT
5
R3
CL
1/4" PER
FT. MIN.
1/4" PER
FT. MIN.
R2
1/4" PER
FT. MIN.
R4
1/4" PER
FT. MIN.
4
1'-0"
R7
R11
R9
R2
R8
2580 BELL ROAD
AUBURN, CA 95603
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
6
R9
R8
1'-0"
Client:
47'-4"
V.I.F
R9
R5
R7
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
R6
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
R6
3
Revisions:
R4
R2
R9
2
No.
Description
Project No.:
Drawn By:
1/4" PER
FT. MIN.
R7
Reviewed By:
Scale:
Date:
Filename:
Date
15.083.10
JA
-RN
-AS NOTED
03-11-15
--
Sheet Title:
1
ROOF PLAN
N
R8
R10
Sheet #:
ROOF PLAN
A-141
SCALE
1/4" = 1' - 0"
1
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
01
TEMPORARY GRAPHIC DURING CONSTRUCTION
SCALE
1/4" = 1' - 0"
14'-5" NEW
STOREFRONT V.I.F.
1
01
02
TRIM SIDES OF GRAPHIC CLING TO FIT WINDOW, IF NECESSARY, TYPICAL.
03
GRAPHIC ON INTERIOR WALL BEYOND.
04
EXISTING STOREFRONT TO REMAIN. ENSURE LIKE NEW CONDITION.
05
INFILL W/ NEW GLAZING AFTER REMOVAL OF KNEE WALL, TYP.
06
NEW STOREFRONT DOORS TO BY L.L. G.C.
07
WF-1 PROVIDED AND INSTALLED BY TENANT VENDOR
08
TENANT SIGNAGE. PROVIDED AND INSTALLED BY TENANT SIGN VENDOR. G.C. T
PROVIDE BLOCKING AND POWER AS REQUIRED.
3'-0" NEW
STOREFRONT V.I.F.
Seal:
A Project for:
09
EXTERIOR WINDOW FILM WF-7 PROVIDED & INSTALLED BY TENANT SIGN VENDO
KEYNOTES
SCALE
-
2'-11"
V.I.F.
TENANT IMPROVEMENT
-
EAST ELEVATION - STORGEFRONT SIGNAGE
SCALE
1/4" = 1' - 0"
2
2580 BELL ROAD
AUBURN, CA 95603
02
(6) 3'-6" x 6'-0" VINYL CLINGS FURNISHED BY RUE 21, INSTALLED BY GC.
COORDINATE INSTALLATION WITH RUE 21 REGIONAL DIRECTOR OF
CONSTRUCTION. VINYL CLINGS ARE TEMPORARY AND TO BE REMOVE AT STORE
OPENING.
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
NOTE:
WHEN STOREFRONT IS NARROWER THAN 52'-0"; THE
OUTWARD MOST PANELS WILL BE DELETED FIRST.
THE PANELS INCLUDING IMAGES ARE ALWAYS TO
REMAIN AS PART OF THE BARRICADE GRAPHIC
REGARDLESS OF SIZE.
Client:
OPEN
OPEN
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
2'-11"
V.I.F.
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
09
04
05
SOUTH ELEVATION - STORGEFRONT SIGNAGE
09
SCALE
1/4" = 1' - 0"
4
04
05
NORTH ELEVATION - STORGEFRONT SIGNAGE
SCALE
1/4" = 1' - 0"
3
1.
DO NOT SCALE DRAWINGS.
2.
REFER TO SHEET G-102 FOR RESPONSIBILITIES.
3.
REPAIR AND PAINT STOREFRONT FACADE AS REQUIRED FOR LIKE NEW CONDITION.
4.
ALL STOREFRONT ELEMENTS TO BE NEW UNLESS NOTED OTHERWISE.
5.
ANY MATERIALS/FINISHES TO BE REUSED MUST BE REFURBISHED TO LIKE NEW
CONDITION.
No.
Description
Project No.:
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
Sheet Title:
EXTERIOR
ELEVATIONS
Sheet #:
WEST ELEVATION - STORGEFRONT SIGNAGE
SCALE
5
GENERAL NOTES
SCALE
A-201
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
1
VINYL WALL GRAPHIC PROVIDED AND INSTALLED BY TENANT SIGN VENDOR
2
SLATWALL - REFER TO A-102 FOR MORE INFORMATION.
3
SEAM BETWEEN FINISHES TO BE CENTERED BEHIND WALL STANDARD OR AS
DIMENSIONED ON PLAN. SEE FIXTURE PLAN AND FINISH PLAN
4
WALL MOUNTED STANDARDS (WS) - REFER TO A-102 FOR MORE INFORMATION
5
SW1/SW2/SW3 - REFER TO FIXTURE LEGEND ON SHEET A-102 FOR MORE
INFORMATION.
6
SAWTOOTH DISPLAY - REFER TO SHEET A-102 FOR MORE INFORMATION.
4'-6" SW1
3'-212" ST
TYPICAL
TYPICAL
10'-0" WS-2
14'-7"
11'-0" TOP OF SLATWALL
14'-7"
1'-0"
TYP
1'-0"
TYP
10'-0" WS-1 TYPICAL
11'-0" TOP OF SLATWALL
1'-0"
TYP
7'-0"
14'-7"
14'-7"
TYPICAL
11'-0" TOP OF SLATWALL
1'-0"
TYP
10'-8" TYPICAL
10'-0" WS-1 TYPICAL
4"
TYP
TYPICAL
10'-0" WS-1 TYPICAL
9'-112" SW1
1
Seal:
7
FALCON SYSTEM - REFER TO SHEET A-102 FOR MORE INFORMATION.
8
STOREFRONT SYSTEM, REFER TO A-102 FOR INFORMATION.
9
MIRROR (M)
10
COAT HOOK (CH)
4
TYPICAL
TYPICAL
2
TYPICAL
TYPICAL
A
TO DECK
TYPICAL
B
TYPICAL
TYPICAL
C
D
INTERIOR ELEVATIONS @ GUYS
A Project for:
SCALE
1
1/4" = 1' - 0"
18'-9" SW2
17'-6" SW2
2'-0"
SW1
TYPICAL
17'-7" SW1
TYPICAL
11
ACCESSIBLE FITTING ROOM BENCH (B2)
12
FITTING ROOM BENCH (B1)
13
MUSIC SYSTEM INSIDE DATA CABINET
14
MUSIC AMPLIFIER ON TOP OF DATA CABINET
TYPICAL
TYPICAL
TYPICAL
C
D
SCALE
2
1/4" = 1' - 0"
4
TYPICAL
TYPICAL
A
4
TYPICAL
TYPICAL
B
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
TYPICAL
A
SCALE
INTERIOR ELEVATIONS @ RUE+
3
SCALE
1/4" = 1' - 0"
SYMBOLS
4
SCALE
-
ALL ELECTRICAL COMPONENTS
MUST BE UL LISTED
1.
DO NOT SCALE DRAWINGS.
2.
REFER TO G-102 FOR RESPONSIBILITIES.
AREA MUST BE FIELD VERIFIED
PRIOR TO FABRICATION
3.
REFER TO G-102 AND A-103 FOR ADDITIONAL FINISH INFORMATION.
-
4.
1
SALES AND FITTING AREA. WALL PROTEX, OR EQUAL
14'-7"
FOR OPEN CEILING STORES,
CONDUIT GOES TO BAR JOIST
MUSIC AMPLIFIER
ALIGN WITH
BAR JOIST
SALES/STOCK
STUD WALL, SEE
A-101
JUNCTION BOX
RECESSED IN WALL
SAFE TO BE ANCHORED TO FLOOR
WITH PROVIDED HARDWARE
1
REFER TO FIXTURE INSTALLATION GUIDE PROVIDED BY ICS FOR COMPLETE
SPECIFICATIONS AND INSTALLATION GUIDE FOR FITTING ROOM ELEMENTS.
7.
CLEAR CAULK EDGES OF ALL FITTING ROOM FIXTURES INCLUDING BUT NOT LIMITED TO
BENCH, COAT HOOK, BASE, TRI, ETC.
No.
Description
Project No.:
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
Sheet Title:
INTERIOR
ELEVATIONS
TYPICAL
EQUIPMENT SECTION
SCALE: 1/4" = 1-0"
INTERIOR ELEVATIONS @ STOCK AREA
6.
1'-0"
TYP
FRONT OF SAFE TO BE
FLUSH WITH FRONT OF
LEGS AS SHOWN
6A
REFER TO A-102 FOR FIXTURE INFORMATION
TYPICAL
DATA CABINET
A
5.
10'-0" WS-1 TYPICAL
CONDUIT(S) WITH CAT5
LINES. REFER TO ELECTRICAL
DRAWINGS
14'-7"
2
6A
A-401
TYPICAL
C
1/4" = 1' - 0"
TYPICAL LAYOUT, NOT SITE SPECIFIC.
WALL FINISH SYMBOL, REFER TO A-103 FOR MORE INFORMATION
4
TYPICAL
INTERIOR ELEVATIONS @ TAREA
Client:
1'-0"
TYP
10'-0" WS-1 TYPICAL
1'-0"
TYP
4
TYPICAL
10'-0" WS-1 TYPICAL
TYPICAL
11'-0" TOP OF SLATWALL
14'-7"
1'-0"
TYP
10'-0" WS-1 TYPICAL
14'-7"
TYPICAL
1'-0"
TYP
10'-0" WS-1 TYPICAL
14'-7"
TYPICAL
-
1'-0"
TYP
TYPICAL
B
OPEN
SCALE
-
INTERIOR ELEVATIONS @ ETC
TYPICAL
TENANT IMPROVEMENT
14'-7"
10'-0" WS-1 TYPICAL
14'-7"
TYPICAL
A
KEYNOTES
14'-7"
TYPICAL
TO
DECK
11'-0" TOP OF SLATWALL
14'-7"
14'-7"
11'-0" TOP OF SLATWALL
7'-0"
11'-0" TOP OF SLATWALL
1
2580 BELL ROAD
AUBURN, CA 95603
TYPICAL
6
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
TYPICAL
4
5
4"
TYP
4
A
SCALE
1/4" = 1' - 0"
6
Sheet #:
INTERIOR ELEVATIONS @ RUE+
SCALE
1/4" = 1' - 0"
5
GENERAL NOTES
SCALE
-
A-401
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
VINYL WALL GRAPHIC PROVIDED AND INSTALLED BY TENANT SIGN VENDOR
2
SLATWALL - REFER TO A-102 FOR MORE INFORMATION.
3
SEAM BETWEEN FINISHES TO BE CENTERED BEHIND WALL STANDARD OR AS
DIMENSIONED ON PLAN. SEE FIXTURE PLAN AND FINISH PLAN
4
WALL MOUNTED STANDARDS (WS) - REFER TO A-102 FOR MORE INFORMATION
5
SW1/SW2/SW3 - REFER TO FIXTURE LEGEND ON SHEET A-102 FOR MORE
INFORMATION.
6
SAWTOOTH DISPLAY - REFER TO SHEET A-102 FOR MORE INFORMATION.
10'-0" WS-1 TYPICAL
14'-7"
TYPICAL
1
Seal:
FALCON SYSTEM - REFER TO SHEET A-102 FOR MORE INFORMATION.
8
STOREFRONT SYSTEM, REFER TO A-102 FOR INFORMATION.
9
MIRROR (M)
10
COAT HOOK (CH)
1'-0"
TYP
7
8
7
TYPICAL
A
INTERIOR ELEVATIONS @ SALES AREA MAIN ENTRANCE
SCALE
1
1/4" = 1' - 0"
11
ACCESSIBLE FITTING ROOM BENCH (B2)
12
FITTING ROOM BENCH (B1)
KEYNOTES
SCALE
-
1
A
B
C
TYPICAL
D
INTERIOR ELEVATIONS @ EXTERIOR WINDOWS
SCALE
1/4" = 1' - 0"
TO DECK
10'-0" WS-1 TYPICAL
1'-0"
TYP
TO DECK
TYPICAL
A
14'-7"
10'-0" WS-1 TYPICAL
1'-0"
TYP
1'-0"
TYP
1'-0"
TYP
TO DECK
TYPICAL
TYPICAL
TENANT IMPROVEMENT
TYPICAL
TYPICAL
14'-7"
TYPICAL
10'-0" WS-1 TYPICAL
TYPICAL
14'-7"
TYPICAL
10'-0" WS-1 TYPICAL
TYPICAL
-
TYPICAL
B
TO DECK
TYPICAL
C
D
INTERIOR ELEVATIONS @ RUE+ & JUNIORS
3
SCALE
2
1/4" = 1' - 0"
1
1
2580 BELL ROAD
AUBURN, CA 95603
A Project for:
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
4
A
11'-4"
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5'-0" TYP
OPEN
OPEN
C
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
OPEN
1
B
11'-4"
OPEN
WALL FINISH SYMBOL, REFER TO A-103 FOR MORE INFORMATION
1'-0"
TYP
OPEN
14'-7"
14'-7"
14'-7"
OPEN
1'-0"
TYP
OPEN
1
OPEN
4'-8"
5'-0" TYP
OPEN
1'-1"
7'-0"
1'-212" 2'-0"
7'-0"
OPEN
14'-7"
Client:
Revisions:
D
A
INTERIOR ELEVATION @ FITTING AREA
SCALE
1/4" = 1' - 0"
5
B
INT. ELEVATIONS @ MAIN ENTRANCE
SCALE
SYMBOLS
4
1/4" = 1' - 0"
SCALE
-
1.
DO NOT SCALE DRAWINGS.
2.
REFER TO G-102 FOR RESPONSIBILITIES.
3.
REFER TO G-102 AND A-103 FOR ADDITIONAL FINISH INFORMATION.
-
4.
SALES AND FITTING AREA. WALL PROTEX, OR EQUAL
5.
REFER TO A-102 FOR FIXTURE INFORMATION
6.
REFER TO FIXTURE INSTALLATION GUIDE PROVIDED BY ICS FOR COMPLETE
SPECIFICATIONS AND INSTALLATION GUIDE FOR FITTING ROOM ELEMENTS.
7.
CLEAR CAULK EDGES OF ALL FITTING ROOM FIXTURES INCLUDING BUT NOT LIMITED TO
BENCH, COAT HOOK, BASE, TRI, ETC.
No.
Description
Project No.:
Drawn By:
2'-0"
Reviewed By:
Date
15.083.10
JA
RN
Scale:
Filename:
8'-0"
12
INTERIOR
ELEVATIONS
12
2'-4"
5'-0"
12
Sheet Title:
OPEN
9
A
B
C
INTERIOR ELEVATION @ FITTING RM-D
D
SCALE
1/4" = 1' - 0"
A
9
B
C
INTERIOR ELEVATION @ FITTING RM-C
D
SCALE
1/4" = 1' - 0"
A
8
B
C
INTERIOR ELEVATION @ FITTING RM-B
D
SCALE
1/4" = 1' - 0"
A
7
03-11-15
Date:
2
5'-0"
OPEN
B
2'-0"
CL
C
INTERIOR ELEVATION @ FITTING RM-A
D
SCALE
1/4" = 1' - 0"
Sheet #:
6
GENERAL NOTES
SCALE
-
A-402
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
TOILET ROOM COMPONENT SCHEDULE
EXIST. TO NEW (ADD/
REPLACE)
REMAIN
--
TOILET SEAT
SEE PLUMBING PLANS
2
--
--
B
SINK
SEE PLUMBING PLANS
2
--
RELOCATE EXISTING
C
LEVER HANDLE FAUCET
SEE PLUMBING PLANS
2
--
RELOCATE EXISTING
D
PIPE WRAP
SEE PLUMBING PLANS
--
2
--
(2) 36"
(2) 42"
(2) 18"
ADD 18" VERTICAL BARS
MIRROR
BOBRICK B-290-1836
--
2
CAULK AROUND FIXTURE
PAPER TOWEL HOLDER
BOBRICK B-253
--
2
--
H
TOILET PAPER HOLDER
BOBRICK B-6857
--
2
--
J
SHELVES (SET)
(2) 12"x36" WHITE MELAMINE SHELVES
ON (2) SURFACE MOUNTED STANDARDS
--
2
--
K
SERVICE SINK
SEE MECHANICAL PLANS
--
1
CAULK AROUND FIXTURE
L
HI-LO WATER COOLER WITH
ADA APRON
SEE MECHANICAL PLANS
--
1
HI/ LO COMBINATION,
CAULK AROUND FIXTURE
M
WATER COOLER SCREEN
BOBRICK 1545 D354; CLASSICSERIES
WALL HUNG SCREEN, 18"X48", WHITE
--
2
14'-7"
F
G
2'-0"
OPEN
3
1'-6"
1'-0"
4'-0"
4'-0"
OPEN
2'-0"
2'-0"
C
-
SCALE
-
B
A
2
A-403
4'-6"
B
3'-6"
4'-6"
1'-0"
-
2
A-403
TOILET
ROOM
202
1'-6"
1'-6"
2'-6"
4'-0"
1'-6"
2'-6"
-
MIRROR
3'-0"
3'-0"
4'-0"
9"
HOLD
WOMEN
6"
1'-012"
D
EXIT
CORRIDOR
200 2
1'-6"
4'-9"
4'-0"
4'-0" WP-1
3'-2"
MEN
4'-0" MIN. TYP.
8'-0"
4'-0"
WP-1
3'-4"
2'-10"
1'-7"
3'-4"
4'-0"
WP-1
4'-0"
WP-1
33" - 36"
AFF
8'-0"
3'-0"
2'-0"
9"
HOLD
1'-7"
1
SCALE
C
1'-6"
1'-6"
1'-6"
27"
CLEAR
2'-8"
RIM
2'-9"
SPOUT
3'-3" SPOUT
3'-0"
7'-8"
5'-0"
CLR.
TOILET
ROOM
203
B
3'-6"
6"
1'-0"
KEYNOTES
A
6'-1112"
6'-11"
C
6"
SCALE
1/4" = 1' - 0"
A
1'-0"
A Project for:
INTERIOR ELEVATIONS @ SALES AREA MAIN ENTRANCE
6"
ACCESSORY SCHEDULE
8'-0"
1
CL
D
Seal:
2
NOTE: THE GC SHALL FURNISH & INSTALL TOILET
ROOM COMPONENTS LISTED ON SCHEDULE
9"
ACCESSIBLE FITTING ROOM BENCH (B2)
5'-0"
3
GC TO ENSURE THE EXISTING ITEMS COMPLY WITH NOTES ON THIS PAGE (VERIFY IN FIELD BEFORE BIDDING). IF GC IS PRESENTED
WITH LONG LEAD TIMES, THEY MUST PRESENT A CUT SHEET OF PROPOSED SUBSTITUTION TO RUE21 PROJECT MANAGER.
3'-6"
3
A-403
N
A
B
C
D
ENLARGED TOILET ROOM & INTERIOR ELEVATIONS
SCALE
1/4" = 1' - 0"
2'-10"
POWER POLE, SEE DETAIL 11/A4.1
(3) 2'-10" X 8'-0" FLEXIBLE MESH PIECES
PROVIDED BY TENANT VENDOR, INSTALLED
BY GC.
5"
GRAPHIC, PROVIDED BY TENANT
VENDOR INSTALLED BY GC.
3'-112"
2'-11"
3'-112"
5"
GC TO PROVIDE 1" CONDUIT 10'-0" LONG PAINTED
PT-1 FOR SUPPORT TO FLEXIBLE MESH.
4'-0"
RIGID MESH PANEL, PROVIDED BY
TENANT VENDOR INSTALLED BY GC.
Client:
LOCATIONS OF HOLES TO BE DRILLED
BY GC AS DIMENSIONED, (4) TOTAL.
TYPICAL.
2'-0"
WALL FINISH SYMBOL, REFER TO A-103 FOR MORE INFORMATION
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
(3) 2'-10" X 8'-0" FLEXIBLE MESH PIECES
PROVIDED BY TENANT VENDOR, INSTALLED
BY GC. PLACE CONDUIT IN LAST LOOP OF
MESH. HANG CONDUIT/FLEXIBLE MESH
WITH AIRCRAFT CABLE PER DETAILS 7/A4.1
AND 8/A4.1.
13'-0"
PENDANT FIXTURE AND TRACK
2
2580 BELL ROAD
AUBURN, CA 95603
--
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
2
TENANT IMPROVEMENT
SEE PLUMBING PLANS
BOBRICK (1) B-5806x36, (1) B-5806x42, &
(1) B-5806-x18
COAT HOOK (CH)
5'-0"
CLR.
TOILET
GRAB BARS (SET)
2
NOTES
A
E
MIRROR (M)
3'-0"
MODEL #
1'-6"
ITEM
8'-0"
MARK
1
3A
A-403
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
7'-0"
6'-6"
7'-2"
CASHWRAP
B
CONDUIT / FLEXIBLE MESH DETAIL
Revisions:
SCALE: N.T.S.
A
POWER POLE DETAIL
SCALE: 3/8" 1'-0"
CASH WRAP ELEVATION, CONDUIT FLEXIBLE MEST DETAIL & POWER POLE DETAIL
SCALE
3/8" = 1' - 0"
3
SYMBOLS
SCALE
-
UNISTRUT TO RUN BETWEEN TOP
CHORD OF JOISTS, PROVIDED AND
INSTALLED BY GC.
LIGHTING TRACK MOUNTED ON
UNISTRUT. SEE DETAIL 3/A5
1.
DO NOT SCALE DRAWINGS.
2.
REFER TO G-102 FOR RESPONSIBILITIES.
3.
REFER TO G-102 AND A-103 FOR ADDITIONAL FINISH INFORMATION.
-
4.
SALES AND FITTING AREA. WALL PROTEX, OR EQUAL
13'-0" AFF
3'-107 8"
3'-107 8"
1'-4"
10'-0" AFF
1'-4"
5.
REFER TO A-102 FOR FIXTURE INFORMATION
6.
REFER TO FIXTURE INSTALLATION GUIDE PROVIDED BY ICS FOR COMPLETE
SPECIFICATIONS AND INSTALLATION GUIDE FOR FITTING ROOM ELEMENTS.
7.
CLEAR CAULK EDGES OF ALL FITTING ROOM FIXTURES INCLUDING BUT NOT LIMITED TO
BENCH, COAT HOOK, BASE, TRI, ETC.
8.
GC SHALL FURNISH & INSTALL NEW ACCESSORIES IF EXISTING ACCESSORIES TO
BE REUSED ARE NOT IN ACCORDANCE WITH CURRENT ADA REGULATIONS AND/OR
DO NOT MEET REQUIREMENTS OF DRAWINGS.
10'-0" AFF
TRACK LIGHT
9'-2" AFF MIN.
BOTTOM OF FLEXIBLE MESH MUST BE
HIGHER THAN TOP OF SIGN AS TO NOT
OBSTRUCT VIEW OF SIGN.
PENDANT FIXTURE
9.
PENDANT FIXTURE
6'-6" AFF
GC SHALL FURNISH & INSTALL GRAB BARS SO THAT THEY DO NOT ROTATE AND
THERE ARE TO BE NO SHARP OR ABRASIVE ELEMENTS ON OR ADJACENT TO THEM.
EDGES ARE TO HAVE A MINIMUM 1/8" RADIUS.
No.
Description
Project No.:
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
Sheet Title:
10. GC SHALL ENSURE THAT GRAB BAR BACKING AND ATTACHMENT SHALL BE
CONSTRUCTED FOR A 250 POUND POINT LOAD.
GRAPHIC, PROVIDED BY TENANT
VENDOR INSTALLED BY GC.
INTERIOR
ELEVATIONS
& ENLARGED PLAN
11. GC SHALL INSULATE OR COVER ALL HOT WATER AND DRAIN PIPES UNDER
LAVATORY. NO SHARP OR ABRASIVE SURFACES ALLOWED UNDER LAVATORY.
12. GC SHALL ENSURE THAT FAUCET CONTROLS AND OPERATING MECHANISMS ARE
EASILY OPERATED BY ONE HAND AND MUST NOT REQUIRE GRASPING, PINCHING,
OR TWISTING OF THE WRIST. FORCE NEEDED TO ACTIVATE CONTROLS SHALL NOT
EXCEED 5 LBS. FOR LEVER OPERATED OR 15 LBS. FOR PUSH TYPE.
13. GC SHALL FURNISH & INSTALL SOLID BLOCKING IN WALL FOR ALL TOILET
ACCESSORIES.
CASHWRAP SECTION & CASHWRAP DETAILS
SCALE
3/8" = 1' - 0"
4
GENERAL NOTES
SCALE
-
Sheet #:
A-403
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
Seal:
1/2" = 1' - 0"
DOUBLE STUD JAMB
SCALE
1/2" = 1' - 0"
7
6
HEADER DETAIL & SCHEDULE
SCALE
HEADER DETAIL & SCHEDULE
4
1/2" = 1' - 0"
SCALE
TYP. METAL STUD CONDITIONS
3
1/2" = 1' - 0"
SCALE
1/2" = 1' - 0"
2580 BELL ROAD
AUBURN, CA 95603
SCALE
TENANT IMPROVEMENT
SLIP TRACK
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
A Project for:
2
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
DUCT OPENING VARIES
IN SIZE: MAX. 1" LARGER
THAN DUCT DIM.
EXTEND TO STRUCTURE
ABOVE AT ALL DOOR
AND WINDOW JAMBS
2
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
FINISH CEILING LINE
METAL STUDS @ 16' O.C
SEE SCHEDULE FOR
INTERIOR PARTITION
3
RUNNER TRACK SAME
GA AS STUDS
Revisions:
3
5
3
3
3
3 STUDS MIN.
OPEN
6
No.
4
5
Description
Project No.:
6
#8 S.M.S @ EA.
STUD BOTH SIDES
Drawn By:
Reviewed By:
Scale:
Date:
5
Filename:
Date
15.083.10
JA
RN
AS NOTED
03-11-15
--
Sheet Title:
OPEN
1"x20 GA. STUDS @ 16"
O.C (TYP)
5
FASTEN STUDS TO
TRACK W /#8 S.M.S
EACH SIDE TYP.
RUNNER TRACK SAME
GA AS STUDS
WALL FRAMING
DETAILS
FINISH FLOOR
5
BACKING CHANNELS
SEE X/A-501
NOTE:
METAL FRAMING DETAILS ARE FOR GENERAL FRAMING INFORMATION AND ARE
TO BE USED WHERE OTHER SPECIFIED INFORMATION IS NOT GIVEN IN THESE
PLANS. SEE DETAIL 1/A110 FOR BLOCKING / FRAMING OF FITTING ROOM DOORS
Sheet #:
A-501
BOTOOM TRACK DETAIL
SCALE
1/2" = 1' - 0"
5
INTERIOR METAL STUD WALL FRAMING
SCALE
1
NOT FOR CONSTRUCTION
1/2" = 1' - 0"
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
ROOF DECK
ROOF DECK
UNISTRUT BETWEEN JOISTS
EXISTING ROOF DECK
UNISTRUT BETWEEN JOISTS
STOREFRONT
1-5/8" UNISTRUT P1000KO CHANNEL
AND P3184 CLOSURE STRIP TO SPAN
LENGTH OF SPIDER TRACK, AS
INDICATED ON PLAN. PAINT PT-1
JOISTS
BOX BEAM PAINTED PT-1
ALL-THREAD
6"
PIPE HANGER
1'-0"
SPIDER TRACK, AFFIXED TO BOX BEAMS
ABOVE. WHERE TRACK EXTENDS
BEYOND BOX BEAM BRIDGE UNISTRUT
EVERY 4'-0" MAX WITH ADDITIONAL
CHANNEL AND ATTACH TO DECK ABOVE
PER DETAIL 19/A-502
SPIDER TRACK DETAIL
SCALE
1-1/2" = 1' - 0"
20
UNISTRUT PROVIDED AND INSTALLED BY
GC, MOUNTED BETWEEN JOISTS
4x4 FLAT COVER PLATE W/ 12" KNOCKOUT
FURNISHED & INSTALLED BY EC.
GRID PANEL- ECONOCO- P3WTE28.
PROVIDED BY TENANT VENDOR, INSTALLED
BY GC. SECURELY FASTENED TO UNISTRUT.
1
2" CONNECTOR W/ SET SCREW
FURNISHED & INSTALLED BY EC.
JOISTS
CABLE PROVIDED BY TENANT VENDOR TO
BE INSTALLED FOR SPECIFIED CEILING
ELEMENTS BY GC. ATTACH CEILING
ELEMENTS PER MANUFACTURER'S
SPECIFICATIONS.
1
2" RIGID CONDUIT. FIELD VERIFY LENGTH.
BOTTOM OF DOME TO BE AT 12'-0" A.F.F.
FURNISHED & INSTALLED BY EC.
114" RIGID PIPE
10'-0" A.F.F.
PARTITION
4x4 JUNCTION BOX FURNISHED &
INSTALLED BY EC.
Seal:
DUMMY DOME ASSEMBLY FURNISHED
BY TENANT VENDOR, INSTALLED BY GC.
JOISTS
HANGING ROD DETAIL
SCALE
1-1/2" = 1' - 0"
15
SECURITY DOME DETAIL
SCALE
1-1/2" = 1' - 0"
SCALE
10
1/2" = 1' - 0"
5
BRANCH CIRCUIT TO
FIXTURE BY EC
A Project for:
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
14'-0" A.F.F. (V.I.F.)
UNDERSIDE OF DECK
EXISTING ROOF DECK
UNISTRUT BETWEEN JOISTS
JOISTS
ALL-THREAD
UNISTRUT PROVIDED AND INSTALLED
BY GC. SEE DETAIL 5/A-502
SPIDER TRACK, SCREWED TO UNISTRUT
42" WIDE PORTION OF ELEMENT
CABLES PROVIDED BY TENANT
VENDOR. INSTALLED BY GC PER
MANUFACTURERS
SPECIFICATIONS
3/4" THREADED RIGID CONDUIT BY
EC. LENGTH OF PENDANT TO BE
DETERMINED IN FIELD TO
ACHIEVE MOUNTING HEIGHT OF
FIXTURE AS INDICATED.
UNISTRUT
13'-6" AFF
13'-11"+/- A.F.F.
ETC EXCLAMATION POINT
SUSPENDED SIGN. PROVIDED
BY TENANT VENDOR, INSTALLED
BY GC.
36" WIDE PORTION OF ELEMENT
12'-0" A.F.F.
MOUNTING BRACKET
9'-0" AFF
TENANT IMPROVEMENT
4 SQUARE JUNCTION BOX
SECURED TO UNISTRUT
SPANNING JOISTS, BY EC. EC TO
PROVIDE THREADED FITTING ON
J-BOX FOR 3/4" THREADED RIGID
CONDUIT (PENDANT). SECURE
J-BOX AS REQUIRED TO SUPPORT
WEIGHT OF FIXTURE. PROVIDE A
SWIVEL ADAPTOR AT J-BOX FOR
SLOPED CEILING INSTALLATIONS.
TYPE 'A' LIGHT FIXTURE
*PREFERRED MOUNTING HEIGHT FOR FRONT OF ETC! SIGN IS 13'-6" AFF. GC TO
MAINTAIN 4'-6" HEIGHT DIFFERENCE FROM FRONT TO BACK. IF THIS CANNOT BE
ACHIEVED, ALERT LAMI GRUBB AND RUE21 ASAP. THE FRONT OF THE SIGN IS NOT TO
BE MOUNTED LOWER THAN 13'-0" AFF.
ATTACHMENT DETAIL WITHOUT BOX BEAM
SPIDER TRACK DETAIL
SCALE
1-1/2" = 1' - 0"
19
NOTE: ALL THREADED ROD,
FASTENERS AND ASSOCIATED
HARDWARE TO BE PAINTED PT-1
#12-14 TEK SCREWS, TYPICAL AT EVERY 12" OC.
(4) SCREWS THROUGH VERTICAL STUD INTO
BOX BEAM, (4) SCREWS THROUGH TOP PLATE
OF WALL INTO TOP OF BOX BEAM
14
EXPOSED DATA CABLING FROM
DATA CABINET
THIS END TO BE
MOUNTED AT 13'-6" AFF
BOLTED CONNECTIONS TO TRACK
(SUPPLIED & INSTALLED BY EC)
TOP OF TRACK
12'-0" AFF U.N.O.
BOX BEAM ATTACHMENT
DETAIL
E.C. TO INSTALL CONTINUOUS TRACK WHEREVER POSSIBLE.
STORE
ENTRANCE
THIS END TO BE
MOUNTED AT 9'-0" AFF
12'-0" A.F.F.
MOVE HEIGHT DOWN TO MATCH
WHEN MOVING LIGHTS DOWN
4 SQUARE JUNCTION BOX
MOUNTED TO CONDUIT. PROVIDE
1/2" KNOCK OUT FOR POWER
CABLE, MOUNTING PLATE/J-BOX
COVER BY EC.
"
3 5/8"X20 GA CONTINUOUS
UNPUNCHED TRACK
3/4" THREADED RIGID CONDUIT.
LENGTH OF PENDANT TO BE
DETERMINED IN FIELD TO
ACHIEVE MOUNTING HEIGHT OF
FIXTURE AS INDICATED.
3'-0
LIGHTING TRACK, SUPPLIED BY
TENANT VENDOR, INSTALLED BY EC.
5/8" DRYWALL
4 SQUARE JUNCTION BOX
SECURED TO STRUCTURE.
PROVIDE THREADED FITTING ON
J-BOX FOR 3/4" THREADED RIGID
CONDUIT (PENDANT). PROVIDE A
SWIVEL ADAPTOR AT J-BOX FOR
SLOPED CEILING INSTALLATIONS.
"
3 5/8"X20 GA CONTINUOUS UNPUNCHED TRACK
"
9'-0
WIRELESS MOUNTING PLATE AND
ANTENNA PROVIDED BY CISCO
AND INSTALLED BY TECH SERVE.
ANGLED CONNECTORS, PROVIDED BY TENANT VENDOR.
TRACK IS NOT TO BE CONNECTED UNLESS SHOWN ON
PLAN.
3 5/8"X20 GA STEEL STUD
1" = 1' - 0"
3'-6
1/4" THREADED SUPPORT ROD @
INTERVALS/HOLES IN TRACK,
SECURED TO STRUCTURE
ABOVE (SUPPLIED & INSTALLED
BY EC)
#12-14 TEK SCREWS,
TYPICAL AT EVERY 12" OC
SCALE
ETC EXCLAMATION POINT
5/8" DRYWALL
3 5/8"X20 GA CONTINUOUS UNPUNCHED TRACK
HIGHBAY MOUNTING DETAIL
BOX BEAM DETAIL
BOX BEAM / BRACING DETAIL
SCALE
1-1/2" = 1' - 0"
23
TRACK MOUNTING DETAIL
SCALE
6" = 1' - 0"
18
WIFI MOUNTING DETAIL
SCALE
1" = 1' - 0"
13
ENLARGED HANGING ETC! DETAIL
SCALE
1/2" = 1' - 0"
2580 BELL ROAD
AUBURN, CA 95603
UNISTRUT BETWEEN
JOISTS, BY EC.
3
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
"
-18
16" P.)
(TY
* ALL TUBES AT 30" IN LENGTH
* PREFERRED MOUNTING HEIGHTS SHOWN ABOVE. IF THIS CANNOT BE
ACHIEVED, ALERT LAMI GRUBB AND RUE21 ASAP. THE BOTTOM OF THE
TUBES ARE NOT TO BE MOUNTED LOWER THAN 8'-0" AFF.
* ATTACH EACH TUBE TO GRID AT 3 POINTS
* SEE 13/A4.1 FOR SPACING
* ALL CYLINDERS AT 30" IN LENGTH
* PREFERRED MOUNTING HEIGHTS SHOWN ABOVE. IF THIS CANNOT BE
ACHIEVED, ALERT LAMI GRUBB AND RUE21 ASAP. THE BOTTOM OF THE
CYLINDERS ARE NOT TO BE MOUNTED LOWER THAN 8'-0" AFF.
* ATTACH EACH CYLINDER TO GRID AT 3 POINTS
* SEE 5/A4.1 FOR SPACING
GRID PANEL ABOVE
SMALL TUBE
(13" SQUARE)
No.
GRID PANEL ABOVE
Description
Project No.:
GRID PANEL ABOVE
Drawn By:
SMALL TUBE
(18" DIAMETER)
SMALL TUBE
(13" SQUARE)
Reviewed By:
Scale:
SMALL TUBE
(18" DIAMETER)
Date:
LARGE TUBE
(28" DIAMETER)
Filename:
Date
15.083.10
JA
RN
AS NOTED
03-11-15
--
Sheet Title:
STORE
ENTRANCE
LARGE TUBE
(28" DIAMETER)
CEILING
MOUNTED
DETAILS
STORE
ENTRANCE
LARGE TUBE
(18" SQUARE)
SMALL TUBE
(18" DIAMETER)
Sheet #:
SMALL TUBE (13" SQUARE)
TUBE LAMP DETAIL
A-502
SCALE
1/2" = 1' - 0"
21
LAMPSHAPE DETAIL
SCALE
1/2" = 1' - 0"
11
ENLARGED FABRIC TUBES DETAIL
SCALE
1
NOT FOR CONSTRUCTION
1/2" = 1' - 0"
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
(E) ROOFING
1'-0"
OVERLAP
SLATWALL TRIM EDGE
ROOFING MATERIAL,
TO MATCH EXISTING
WALL STANDARD
1 LAYER TYPE 15 FELT
PAPER
(N) CDX PLY SHEATHING,
TO MATCH EXISTING w/ 8d
@ 12" O.C
WOOD END CAP TO
EXTEND TO FLOOR.
SLATWALL
WALL TO DECK
6" SOUND BATT
3-5/8" TOP & BOTTOM TRACK
6" TOP & BOTTOM TRACK
3-5/8" 20 GA METAL STUDS @ 16" O.C
TO 8'-0" AFF (UNO)
6" 20 GA. METAL STUD @ 16" O.C TO
11'-4" A.F.F (U.N.O)
5/8" GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
Seal:
2x BLOCKING w/ (2) 16d
NAILS EA WAY WITH A34
CLIP
1" = 1' - 0"
SCALE
25
3" = 1' - 0"
20
ENLARGED END WALL DETAIL
SCALE
3/4" = 1' - 0"
15
WALL TYPE - 10
@ DRESSING ROOM
SCALE
1-1/2" = 1' - 0"
10
WALL TYPE - 5
PLUMBING WALL
SCALE
1-1/2" = 1' - 0"
5
2X6 T&G DECKING
2X WOOD CURB ASSEMBLY
A Project for:
20 GA. G.I. COVER ON PLATFORM
FULL SOLDER SEAM
TOP OF TYPE B1 WALL
BASE FLASHING FASTENER
AT 6" O.C.
SEE WALL TYPES,
FOR MORE INFORMATION
EXTEND WOOD TOP CAP 1" BEYOND
BACK EDGE OF WING WALL
FLASHING MEMBRANE
SET INTO HOT ASPHALT
.177x 1-7/16" POWER DRIVEN
FASTENERS 8" FROM ENDS @ 24"
O.C.
16 GA METAL RUNNER TRACT
w/ #8 S.M.S EA. SIDE
1"
FIBERGLASS FELT FLASHING
PLY-SET INTO HOT ASPHALT
7-1/2" MIN.
4" FIBER CANT STRIP
(E) ROOFING MATERIAL
2"
ACOUSTICAL SEALANT EA. SIDE
TOP SET BASE
AND FLOORING
PER FINISH
SCHED.
2"
SIDE OF WING WALL,
SEE 1/A-601 FOR FINISH
(E) FLOOR STRUCTURE
3-5/8" TOP & BOTTOM TRACK
3-5/8" TOP & BOTTOM TRACK
3-5/8" 20 GA METAL STUDS @ 16" O.C
TO 11'-4' AFF (UNO)
3-5/8" 20 GA METAL STUDS @ 16" O.C
TO 11'-4' AFF (UNO)
5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
PLYWOOD
DECK
PURLIN OR HEADER BELOW
MECHANICAL PLATFORM
ICBO No. 2388
WING WALL SIDE ELEVATION
SCALE
3" = 1' - 0"
24
WING WALL SIDE ELEVATION
SCALE
3" = 1' - 0"
3'-0"
WALL SILL
19
DETAIL
3'-0" x 2'-6" METAL ROOF ACESS
HATCH W/ INTEGRAL BASE
ADJACENT WALL-SEE CONSTRUCTION PLAN
FOR PARTITION TYPE
#8 SCREW, TYP.
(E) ROOFING MATERIAL
4"
1-1/2" = 1' - 0"
WALL TYPE - 4
FULL HEIGHT WALL @ STOCK RM
SCALE
1-1/2" = 1' - 0"
4
EXISTING OR NEW
2x BLOCKING @ 24" O.C
17
A-503
TOP OF WOOD END CAP
CUT STUDS 1" SHORT OF BOT. OF
DECK, SECURE TO INNER TRACK,
FRICTION FIT ONLY. INNER TRACK IN
OUTER TRACK
SIDE OF WING WALL,
SEE 1/A-601 FOR FINISH
(E) 6" SOUND BATT
6" 20 GA. METAL STUD @ 16" O.C TO
11'-4" A.F.F (U.N.O)
(E) 6" 20 GA. METAL STUD @ 16" O.C
5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
(E) 5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
SEE WALL TYPES,
FOR MORE INFORMATION
17
A-503
WOOD BLOCKINGWHERE OCCURS
6" TOP & BOTTOM TRACK
ACOUSTICAL SEALANT ON EA SIDE
TOP OF WALL
11'-4" A.F.F.
VARIES TO F.F.
4'-0" MAX. O.C.
@ SALES AREA
9
(E) TJI @ 48" O.C (V.I.F)
11'-4 3/4" A.F.F.
20 GAUGE, 6" METAL STUD JOISTS @ 16"
O.C. DOUBLE JOISTS UNDER WATER
HEATER. DOUBLE AT SIDES OF ACCESS
PANEL
14
SCALE
WT-1 WALL TRIM BUTTED AGAINST WING WALL.
WOOD TOP CAP WILL OVERHANG 1/4" ON
EITHER SIDE
TOP OF HORIZONTAL WOOD END CAP TO ALIGN
WITH TOP OF VERTICAL WOOD END CAP. BUTT
SELF FLASHING CURB, EXTEND
JOINT PIECES AS TIGHTLY TOGETHER AS
12" BASE FRAME
POSSIBLE. CENTER ON TOP OF PARTITION.
(3) #8 SCREWS TRACK TO STUD, TYP.
6"
3" = 1' - 0"
WALL TYPE - 9
FACE OF
PERIMETER WALL
SECTION PARALLEL TO PLUMBING CHASE
6" 20 GAUGE METAL STUD TRACK
ALONG WALL BEYOND
SCALE
STEEL ACCESS LADDER
-SEE 22/A-503
HOT WATER PLAT FORM
SCALE
ROOF HATCH
28
1-1/2" = 1' - 0"
SCALE
1-1/2" = 1' - 0"
23
WING WALL SIDE ELEVATION
SCALE
3" = 1' - 0"
18
PARTITION CONNECTIONS
SCALE
PARRALLEL VIEW
1" = 1' - 0"
13
WALL TYPE - 8
@ SALES AREA
SCALE
1-1/2" = 1' - 0"
8
WALL TYPE - 3
SCALE
EXISTING FULL HEIGHT WALL
1-1/2" = 1' - 0"
2580 BELL ROAD
AUBURN, CA 95603
SCALE
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
ROOFING PATCHING
TENANT IMPROVEMENT
(E) 2x RAFTERS
4'-6" WALL WIDTH,
NOT INCLUDING WOOD END CAP
INFILL OPENING
1'-0"
OVERLAP
WOOD END CAP
3
Client:
WALL LINE
6"
6"
PLAN
3/8"x 2" FLAT STL. BAR
SUPPORTS EACH SIDE
WELDED TO STRINGERS
4'-0" OC. MAX.
2"
A-503
CLARK DIETRICH; 400 SERIES J
TRIM (OR APPROVED EQUAL). TAPE
INTO DRYWALL SO IT IS NOT
VISIBLE.
12" MAX.
TOP OF WALL
20
A-503
RUNGS AT 12" OC. WELDED
TO STRINGERS
27
1" = 1"
ACCESS LADDER
SCALE
1" = 1' - 0"
22
ENLARGED END CAP DETAIL
35 8"
1"
3
4"
BARE CONCRETE STOCK ROOM
FLOORING (CF-2)
GRAY VINYL TRANSITION STRIP
VT-1 FLOORING IN TOILET ROOM
A-503
4"
TOP OF WALL
20
A-503
PRE FINISHED MDF WALL TRIM
WALL BASE
EXISTING CONCRETE SLAB,
PREPARE AS NEEDED FOR NEW
FLOORING
SCALE
1" = 1"
26
ACOUSTICAL SEALANT ON EA SIDE
(E) 3" SOUND BATT
3-5/8" 20 GA METAL STUDS @ 16" O.C
TO 11'-4' AFF (UNO)
CUT STUDS 1" SHORT OF BOT. OF
DECK, SECURE TO INNER TRACK,
FRICTION FIT ONLY. INNER TRACK IN
OUTER TRACK
FLOOR TRANSTION DETAIL
SCALE
6" = 1' - 0"
21
Revisions:
(E) 6" 20 GA. METAL STUD @ 16" O.C
5/8" GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
(E) 5/8" MOISTURE RESISTANT
GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
SEE WALL TYPES,
FOR MORE INFORMATION
NOTE:
PROVIDE BRACING TO STORE FRONT
17
PARTITION CONNECTIONS
SCALE
PERPENDICULAR VIEW
1" = 1' - 0"
12
WALL TYPE - 7
@ STORE FRONT
SCALE
1-1/2" = 1' - 0"
7
WALL TYPE - 2
EXISTING PLUMBING WALL
SCALE
1-1/2" = 1' - 0"
2
WOOD END CAP TO EXTEND FROM 4" AFF
TO 11'-4 3/4" AFF, UNO. CENTER ON END OF
PARTITION.
7-1/2" WOOD END CAP PROVIDED BY
TENANT VENDOR, INSTALLED BY GC. GLUE
TO STUD AND SECURE WITH FINISH NAILS
MINIMALLY. GC TO PAINT BACK PRIOR TO
INSTALLATION. SEE 1/A-103 FOR END CAP
LOCATIONS.
ENTIRE BACK OF WOOD END CAP TO BE
PAINTED AND CAULKED AS SHOWN:
PAINT PT2 AND WHITE CAULK FOR WD2
PAINT PT7 AND BLACK CAULK FOR WD4
ENSURE STRAIGHT EDGE OF CAULK, NOT
TO OVERLAP WOOD END CAP AND NO
FREEHAND EDGES ON PARTITION.
CLARK DIETRICH; 400 SERIES J
TRIM (OR APPROVED EQUAL). TAPE
INTO DRYWALL SO IT IS NOT
VISIBLE.
6" 20GA. UNPUNCHED TRACK W/
(2)-#10 TEKS TO STUDS @ 16" O.C.
1/2" GYPSUM BOARD,
SEE 1/A-601FOR FINISHES.
WOOD END CAPS ARE IN 8' LENGTHS. GC TO
SEAM AT 8'-4" AFF
11'-0" A.F.F.
WALL TRIM - 1
SCALE
3" = 1' - 0"
WALL FACE
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
3-5/8" TOP & BOTTOM TRACK
WOOD END CAPS ARE IN 8' LENGTHS. GC TO
SEAM AT 8'-4" AFF
512"
11'-4" A.F.F.
(E) TJI @ 48" O.C (V.I.F)
1/2" GYPSUM BOARD,
SEE 1/A-601FOR FINISHES.
ELEVATION
SCALE
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
6" 20GA. UNPUNCHED TRACK W/
(2)-#10 TEKS TO STUDS @ 16" O.C.
WALL BASE
FLOOR LINE
WALL FACE
WALL TRIM - 2
ENTIRE BACK OF WOOD END CAP TO BE
PAINTED AND CAULKED AS SHOWN:
PAINT PT2 AND WHITE CAULK FOR WD2
PAINT PT7 AND BLACK CAULK FOR WD4
ENSURE STRAIGHT EDGE OF CAULK, NOT
TO OVERLAP WOOD END CAP AND NO
FREEHAND EDGES ON PARTITION.
SLEEVE ANCHOR W/ 1 1/2" MIN.
EMBED. ONE PER SUPPORT
PROVIDE WOOD BLKG
AT EA SUPPORT WITHIN
WALL CAVITY.
PRE FINISHED MDF WALL TRIM,
TYPICAL ALL SIDES OF FITTING ROOM
1 "
2
4"
16"
7-1/2" WOOD END CAP PROVIDED BY
TENANT VENDOR, INSTALLED BY GC. GLUE
TO STUD AND SECURE WITH FINISH NAILS
MINIMALLY. GC TO PAINT BACK PRIOR TO
INSTALLATION. SEE 1/A-103 FOR END CAP
LOCATIONS.
1/2" MIN
CLR
WALL LINE
3
3
4"
EXTEND TO HATCH
3/8"x 2" FLAT STL. BAR
STRINGER EACH SIDE
8'-0" A.F.F.
WOOD END CAP TO EXTEND FROM 4" AFF
TO 11'-4 3/4" AFF, UNO. CENTER ON END OF
PARTITION.
712"
ENLARGED END CAP DETAIL
(E) STRUCTURE ABOVE
No.
Description
Project No.:
Drawn By:
Reviewed By:
12
13
-
-
3-5/8" TOP & BOTTOM TRACK
Scale:
R11 FIBER GLASS SOUND
CONTROL INSULATION
FOR CEILING TYPE AND HEIGHT 6"
MIN.
SEE CEILING PLAN
7"x 3/4" PRE FINISHED MDF TOP CAP
ON TOP OF WALL
ACCOUSTICAL CEILING,
WHERE OCCURS
SEE WALL TYPES,
FOR MORE INFORMATION
Date:
(E) 8' CMU WALL
Filename:
3-5/8" 20 GA METAL STUDS @ 16" O.C
TO 11'-4' AFF (UNO)
Date
15.083.10
JA
RN
AS NOTED
03-11-15
--
Sheet Title:
(E) 2-1/2" 20 GA. METAL FURRING
CHANNEL @ 16" O.C
DETAILS
5/8" GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
(E) 5/8" GYPSUM BOARD
(PAINTED - SEE FINISH SCHEDULE)
14
-
(E) FLOOR SLAB
Sheet #:
A-503
SCALE
3" = 1' - 0"
16
SCALE
1" = 1' - 0"
11
WALL TYPE - 6
FULL HEIGHT WALL @ SALES AREA
SCALE
1-1/2" = 1' - 0"
6
WALL TYPE - 1
2-1/2" FURRING @ CMU
SCALE
1
NOT FOR CONSTRUCTION
1-1/2" = 1' - 0"
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
WINDOW SCHEDULE
- EXISTING STORE FRONT TO MODIFY FOR NEW DOUBLE DOOR ENTRY, EXISTING FIXED TEMPERED GLAZING
1
6
2*
(E) 80'-0"
V.I.F
--
HM/GL
5
HM
3
4
HM
4
3
HM
5
3
6
6'-0"
PT-9/
PT-3
PT-9/
PT-3
7'-0"
3'-0"
--
7'-0"
--
HM
134"
A
HM
A
HM
3'-0"
7'-0"
134"
PT-3
3'-0"
7'-0"
134"
A
HM
HM
PT-3
3'-0"
7'-0"
134"
A
4
HM
PT-3
3'-0"
7'-0"
134"
7
1
WD
PRE
2'-1034"
5'-0"
8
1
WD
PRE
2'-1034"
5'-0"
-PT-9/
PT-3
PT-9/
PT-3
--
--
6
DOOR FRAME IS INTEGRAL TO STOREFRONT SYSTEM
--
--
3
SEE 3/A-601 FOR PAINT TRANSITION DETAIL
TYPE
MANUFACTURER PRODUCT NUMBER
DESCRIPTION
LAMPING
MTG METHOD
MTG HT
COMMENTS
A
HUBBELL
LBS-360LU-4K-A2-WA16-WH
HIGH BAY LIGHTING
(1) 100W LED
SEE DETAIL 14/A-503
12'-0" AFF
SEE DETAIL 14/A-503 FOR ADDITIONAL INFORMATION
B
COOPER
8TSSF-132-EB81
STRIP LIGHT
AIRCRAFT
CABLE
12'-0" AFF
C
LAZER BY
HALO
D
ARK
SEE 3/A-601 FOR PAINT TRANSITION DETAIL
TRACK HEAD
(1) 13W LED PAR30
TRACK
12'-0" AFF
A30-P1031-AG-GIRL
PENDANT
(1) 40W NOSTALGIC A19
TRACK
12'-0" AFF
BOTTOM OF FIXTURE TO BE 6'-6" AFF
--
--
4
PT-3
--
--
5
--
HM
PT-3
--
--
5
--
E
ARK
A30-P1031-AG-BOY
PENDANT
(1) 40W NOSTALGIC A19
TRACK
12'-0" AFF
BOTTOM OF FIXTURE TO BE 6'-6" AFF
A
HM
PT-3
--
--
4
--
F
GREENHECK
SP-A125-L
COMBO LIGHT/FAN
(1) 50W TYPE-A
CEILING
CLG HEIGHT
EXG = EXISTING TO REMAIN
134"
B
WD
PRE
--
--
1
BLOCKING BY GC. SEE DETAILS 2/A-601
TR
HALO
L651P/L652P
TRACK
--
SEE DETAIL 18/A-503
12'-0" AFF
134"
B
WD
PRE
--
--
1
BLOCKING BY GC. SEE DETAILS 2/A-601
X
COMPASS
CER
EXIT SIGN
INCLUDED
WALL
6" CENTERED ABOVE DOOR
FRAME/BO SOFFIT
X1
COMPASS
CCRRC; C0RS
EXIT SIGN/LIGHT COMBO W/
REMOTE LIGHT
INCLUDED
WALL
6" CENTERED ABOVE DOOR
FRAME/BO SOFFIT
Y
COMPASS
CU2
EMERGENCY LIGHTING
INCLUDED
SUSPENDED FROM ABOVE 12'-0" AFF
Y1
COMPASS
CU2
EMERGENCY LIGHTING
INCLUDED
WALL
9
2
WD
PRE
3'-0"
5'-0"
134"
C
WD
PRE
--
--
2
BLOCKING BY GC. SEE DETAIL 1/A-601
10
1
WD
PRE
2'-1034"
5'-0"
134"
B
WD
PRE
--
--
1
BLOCKING BY GC. SEE DETAILS 2/A-601
11
1
WD
PRE
2'-1034"
5'-0"
134"
B
WD
PRE
--
--
1
BLOCKING BY GC. SEE DETAILS 2/A-601
ALL DOORS TO BE KEYED ALIKE WITH NON REMOVABLE CORES
ALL DOORS TO RECEIVE NEW HARDWARE AS SPECIFIED
GC TO REPAIR EXISTING DOORS (FILL HOLES, ADJUST HINGES AND STRIKES, REPLACE CLOSERS, ETC) TO LIKE NEW CONDITION AND OPERATION.
FITTING ROOMS DOORS (DOORS 1 AND 2 SERIES) FURNISHED BY MILLWORK VENDOR AND SHALL ARRIVE WITH MILLWORK PACKAGE.
Seal:
12'-0" AFF
ALL FIXTURES TO BE NEW UNLESS NOTED OTHERWISE. EXISTING TO BE RELOCATED FIXTURES NOTED WITH 'R'. FIXTURES EXISTING TO REMAIN NOTED WITH 'EXG'
WHERE EXISTING FIXTURES ARE TO REMAIN, REPLACE FIXTURES/BALLASTS AS NEEDED FOR LIKE NEW APPEARANCE AND OPERATION
*GC TO INSPECT, REPAIR, AND/OR REPLACE AS REQUIRED FOR PROPER WORKING ORDER.
CEILING LEGEND
ALL HARDWARE TO BE SCHLAGE UNLESS OTHERWISE NOTED
HARDWARE SET 1:
(2) SELF CLOSING, (1) STANDARD HINGES. SATIN CHROME
(1) EACH, SATIN CHROME LOCKING HAND SET
HARDWARE SET 4:
(3) EACH, 5 KNUCKLE; BALL BEARING; STD. WEIGHT; FULL MORTISE
HINGE; US26D; BUTT HINGES
(1) EACH, PUSH/PULL HARDWARE AND PLATE - ROCKWOOD MFG 111
X 73C/73CL
(1) EACH, DOOR CLOSER - YALE HARDWARE UNI-3511-689-HOLD
OPEN
HARDWARE SET 2:
(3) STANDARD HINGES. SATIN CHROME
(1) EACH, SATIN CHROME LOCKING HAND SET
HARDWARE SET 3:
INSTALLED ON PUSH SIDE
(3) EACH, 5 KNUCKLE; BALL BEARING; STD. WEIGHT; FULL MORTISE
(1) EACH, DOOR STOP - ROCKWOOD MFG 409 x US32D
HINGE; US26D; NRP HINGES
(1) EACH, PANIC HARDWARE - YALE HARDWARE 3828 F EN SARGENT HARDWARE SET 5:
(1) EACH, BLANK COVER PLATE ON EXTERIOR
(3) EACH, 5 KNUCKLE; BALL BEARING; STD. WEIGHT; FULL MORTISE
(1) EACH, DOOR CLOSER - YALE HARDWARE 3511-689
HINGE; MPB79 US 26D; BUTT HINGES
(1) EACH, DOOR PULL BURNS 25a X US32D
(1) EACH, PRIVACY LOCKSET - YALE HARDWARE AU5302LN
(1) EACH, PEEPHOLE - SECURITY PRODUCTS INC. THE DOORSPY DS-6
380BN-497 626
(1) EACH, DOOR BUZZER - TRINE 233 WIRELESS
(1) EACH, DOOR CLOSER - YALE HARDWARE 3511-689
HARDWARE SET 6:
(2) EACH, KICKSTAND DOOR STOP - ROCKWOOD MFG 461L X US26D
(2) EACH, UNI-4400 X 689 DOOR CLOSER - YALE
(2) EACH, BASE BUILDING STANDARD PUSH-BAR
(1) EACH, BASE BUILDING STANDARD DOUBLE DOOR LOCKING
SYSTEM
BASE BUILDING STANDARD DOUBLE DOOR HINGES
(1) EACH, THRESHOLD
INSTALLED ON PUSH SIDE
EXTERIOR TENANT SIGN(S) PER LANDLORD STANDARDS
(1) EACH, PRY GUARD/LATCH PROTECTOR - DON JO CLP-106
WEATHER STRIPPING (EXTERIOR DOORS ONLY) PEMKO 303AV
DOOR SWEEP (EXTERIOR DOORS ONLY)PEMKO 18062
THRESHOLD PEMKO 175A
SPRING LOADED CHAIN - DON JO HDCC3012
DOOR / FRAME TYPES
2'-103 4"
3'-0"
VARIES
VARIES
VARIES
DOOR TYPE
3
DOOR TYPE
2
HM FRAME TO INCLUDE
REINFORCED HEADER
FOR CLOSER
VARIES
2"
2"
DOOR TYPE
6
2'-103 4"
25 8"
25 8"
FRAME TYPE B
3'-012" OUTSIDE OF FRAME
3'-0" INSIDE OF FRAME
2'-11" INSIDE OF FRAME
PT-3 FRAME
6'-814" INSIDE OF FRAME
6'-9" OUTSIDE OF FRAME
4"
6'-103
(2) LAYERS 3/4" FIRE
RATED PLYWOOD
BLOCKING. 5" WIDE.
6'-914" W/ SHIM SPACE
(2) LAYERS 3/4" FIRE
RATED PLYWOOD
BLOCKING. 5" WIDE.
ROUGH OPENING
3'-1" W/ SHIM SPACE
3'-112" OUTSIDE OF FRAME
NON SALES/FITTING AREA SIDE
OF DOOR TO BE PAINTED PT-3
GC TO REFER TO MILLWORK VENDOR'S CONSTRUCTION MANUAL
FOR ADDITIONAL INFORMATION. IF ANY CONFLICT OCCURS,
ALERT RUE21 AND ARCHITECT IMMEDIATELY
3'-4" ROUGH OPENING
3'-2" W/ SHIM SPACE
3'-1" W/ SHIM SPACE
PLAN VIEW
1
(2) LAYERS 3/4" FIRE
RATED PLYWOOD
BLOCKING. 5" WIDE.
3'-012" OUTSIDE OF FRAME
2'-11" INSIDE OF FRAME
2x4 INTERIOR WOOD
FRAMING
GYP BOARD
CEILING
N/A
5/8" GYPSUM BOARD CEILING. MR DRYWALL IN WET AREAS
SEE SHEET A-121 FOR HEIGHT
CL-2
SCRIM SHEETING
LAMTEC
CORPORATION
WMP-10-POLYPROPYLENE/SCRIM/KRAFT
WHITE SCRIM SHEETING MOUNTED TO TOP BAR OF JOIST. PAINT ALL EXPOSED
CEILING ELEMENTS AND JOISTS PT-1.
SEE SHEET A-121 FOR HEIGHT
CL-3
GYP BOARD
CEILING
N/A
EXISTING GYPSUM BOARD CEILING. PATCH/REPAIR TO LIKE NEW CONDITION.
SEE SHEET A-121 FOR HEIGHT
FINISH LEGEND
LABEL
DESCRIPTION
MANUFACTURER
SPECIFICATION
PRODUCT DESCRIPTION
NOTES
FINISH NOTES ON
THIS SHEET
CONCRETE & MASONRY GLOSS SEALER
(8800)
7 STEP POLISHED CONCRETE
PROCESS
SAND CONCRETE SMOOTH. APPLY (2)
COATS MINIMUM.
LANDLORD'S RESPONSIBILITY
TENANT VENDOR
CUSTOM WALL GRAPHIC
LOFT GRAPHIC
SEE SHEET A-102 & A-401 FOR SIZES AND LOCATIONS
WALL GRAPHIC
TENANT VENDOR
CUSTOM WALL GRAPHIC
CLUB 21 FITTING ROOM SCHEME
SEE SHEET A-103 & A-403 FOR LOCATIONS
GR-3
WALL GRAPHIC
TENANT VENDOR
CUSTOM WALL GRAPHIC
SKATER FITTING ROOM SCHEME
SEE SHEET A-103 & A-403 FOR LOCATIONS
GR-4
WALL GRAPHIC
TENANT VENDOR
CUSTOM WALL GRAPHIC
RUNWAY MODEL FITTING ROOM
SCHEME
SEE SHEET A-103 & A-403 FOR LOCATIONS
GR-5
WALL GRAPHIC
TENANT VENDOR
CUSTOM WALL GRAPHIC
ROCK STAR FITTING ROOM SCHEME
SEE SHEET A-103 & A-403 FOR LOCATIONS
GR-6
WALL GRAPHIC
TENANT VENDOR
CUSTOM WALL GRAPHIC
PRINCESS FITTING ROOM SCHEME
SEE SHEET A-103 & A-403 FOR LOCATIONS
PRE
PRE-FINISHED
--
--
DENOTES PRE-FINISHED ITEMS
PT-1
PAINT
BENJAMIN MOORE
OC-18
DOVE WING (LIGHT GRAY)
PT-2
PAINT
BENJAMIN MOORE
OC-66
SNOW WHITE (WHITE)
PT-3
PAINT
BENJAMIN MOORE
HC-166
KENDALL CHARCOAL (DARK GRAY)
PT-4
PAINT
SHERWIN WILLIAMS
SW 6919
FUSION (GREEN)
PT-5
PAINT
SHERWIN WILLIAMS
SW 6907
FORSYTHIA (YELLOW)
PT-6
PAINT
32RR 26/413
TUTTI FRUTTI (PINK)
PT-7
PAINT
GLIDDEN
PROFESSIONAL
BENJAMIN MOORE
INTERIOR READY MIX
BLACK
PT-8
PAINT
BENJAMIN MOORE
OC-15
BABY FAWN (MEDIUM GRAY)
PT-9
PAINT
SHERWIN WILLIAMS
SW 6947
TEMPO TEAL (TEAL)
VT-1
VINYL TILE
ARMSTRONG
51899 COOL WHITE
12" X 12" STANDARD EXCELON VINYL
TILE; COOL WHITE (#51899)
WB-1 WALL BASE
JOHNSONITE
CB-40-4
4" STANDARD TOE BASE; BLACK (#040)
WB-2 WALL BASE
JOHNSONITE
CB-27-6
6" STANDARD TOE BASE; MIST (#027)
WC-1 WALL COVERING
RJF/KOROSEAL
RJF9565 (SILVER)
WD-1 WOOD END CAP
TIMELINE
WHITE WHITE
WD-2 WOOD END CAP
TIMELINE
WHITE WHITE
WD-3 WOOD END CAP
TIMELINE
BLACK BLACK
WD-4 WOOD END CAP
TIMELINE
BLACK BLACK
WF-1
WINDOW FILM
TENANT VENDOR
CUSTOM PRINT
WF-2
WINDOW FILM
NOT USED
WF-3
WINDOW FILM
NOT USED
WF-4
WINDOW FILM
NOT USED
WF-5
WINDOW FILM
NOT USED
WF-6
WINDOW FILM
NOT USED
WF-7
WINDOW FILM
TENANT VENDOR
CUSTOM PRINT
LOFT GRAPHIC WITH LARGE RUE21 TEXT
APPLIED ON EXTERIOR OF GLAZING
WP-1 WALL PANEL
MARLITE
FRP P100
FIBER-REINFORCED PLASTIC WALL
PANEL. WHITE. FROM FF TO 48"AFF
FINISH ALL EXPOSED ENDS WITH PVC MOLDING (WHITE)
WT-1
WALL TRIM
TENANT VENDOR
CUSTOM WALL TRIM
PRE (PT-8) GC TO PAINT PT-8
SEE DETAIL X/A-XXX
WT-2
WALL TRIM
TENANT VENDOR
CUSTOM WALL TRIM
PRE (PT-8) EXCEPT IN FITTING ROOM
INTERIORS (COLOR VARIES BY THEME)
SEE DETAIL X/A-XXX. WALL TYPE 10 ONLY
CF-1
-QUIKRETE
GR-1
CONCRETE
FINISH
CONCRETE
FINISH
WALL GRAPHIC
GR-2
CF-2
CUSTOM VINYL WALLCOVERING. TYPE
2 - CLASS A FIRE RATING
PINE; 5-1/2" WIDE. SQUARE EDGE, FIRE
RATED FINISH.
PINE; CUSTOM 7-1/2" WIDE. SQUARE
EDGE, FIRE RATED FINISH.
PINE; 5-1/2" WIDE. SQUARE EDGE, FIRE
RATED FINISH.
PINE; CUSTOM 7-1/2" WIDE. SQUARE
EDGE, FIRE RATED FINISH.
CUSTOM STREET MAP GRAPHIC PRINT
ON CLEAR POLYESTER FILM.
LANDLORD'S RESPONSIBILITY
GC TO PAINT BACKSIDE PT-2 (WHITE)
GC TO PAINT BACKSIDE PT-2 (WHITE)
GC TO PAINT BACKSIDE PT-7 (BLACK)
GC TO PAINT BACKSIDE PT-7 (BLACK)
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
3
(2) LAYERS 3/4" FIRE
RATED PLYWOOD
BLOCKING. 5" WIDE.
5"
2
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
PLAN VIEW
DOOR 2 BLOCKING DETAIL
SCALE: 1/4" = 1'-0"
FINISH NOTES
A.
GC TO PROVIDE ALL MATERIALS/PRODUCTS REQUIRED FOR INSTALLATION OF FINISH MATERIALS U.N.O. ALL FINISH MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDED
INSTALLATION PROCEDURES. CONTACT THE SALES REP FOR THE PROPER INSTALLATION. IF THEY ARE NOT CONTACTED FOR PROPER INSTALLATION PROCEDURES, THEN THE CONTRACTOR WILL BE HELD
RESPONSIBLE FOR IMPROPER INSTALLATION AND WILL BE REQUIRED TO RE-INSTALL OR CORRECT FINISHES IMMEDIATELY.
2x4 INTERIOR WOOD
FRAMING
GC TO REFER TO MILLWORK VENDOR'S CONSTRUCTION MANUAL
FOR ADDITIONAL INFORMATION. IF ANY CONFLICT OCCURS,
ALERT RUE21 AND ARCHITECT IMMEDIATELY
DOOR 1 BLOCKING DETAIL
SCALE: 1/4" = 1'-0"
A Project for:
NOTES
CL-1
FRAME TO MATCH ADJ. PAINT.
PAINT PT-1 WHERE WC-1 IS
ADJ. FINISH.
ELEVATION VIEW
3'-5" ROUGH OPENING
3'-0" INSIDE OF FRAME
SPECIFICATION
SALES/FITTING AREA SIDE OF
DOOR TO BE PAINTED ADJACENT
PAINT COLOR. PAINT PT-1 WHERE
WC-1 IS ADJ FINISH.
TYPICAL BOTH SIDES
3'-112" OUTSIDE OF FRAME
VARIES
FRAME TYPE C
MANUFACTURER
3'-4" ROUGH OPENING
3'-2" W/ SHIM SPACE
ELEVATION VIEW
1'-4"
6'-814"
6'-81
FRAME TYPE A
3'-5" ROUGH OPENING
25 8"
3'-0"
25 8"
25 8"
4"
VARIES
2"
3'-0"
DOOR TYPE
5
DOOR TYPE
4
25 8"
6'-0"
2'-10"
3'-2"
1'-4"
12"
DOOR TYPE
1
3'-0"
2'-10"
3'-2"
3'-2"
5'-0"
10" 9"
PEEP HOLE
DOOR PULL
DESCRIPTION
2580 BELL ROAD
AUBURN, CA 95603
LABEL
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
DOOR HARDWARE SCHEDULE
TENANT IMPROVEMENT
WINDOW TYPE A
7'-0"
-
3'-0"
-
SYMBOL
HDW
RATING
TYPE MATL FINISHDETAILS
SET
5"
-
THICK
5'-0"
ALUM
GLASS/ REMARKS
SILL
JAMB
12"
A
HEAD
LIGHT FIXTURE LEGEND
FRAME
6'-814" INSIDE OF FRAME
PAINT
FRAME
3'-0"
80'-0" x 10'-0"
FINISH TYPE
6'-9" OUTSIDE OF FRAME
EXT.
DOORS
DOOR
SIZE
TYPE MATL FINISH
#
WIDTH HEIGHT
DETAILS
6'-914" W/ SHIM SPACE
A
ROOM OPENING SIZE
NO.
(E)10'-0"
V.I.F
WDW
NO.
DOOR SCHEDULE
XXX
6'-103 4" ROUGH OPENING
XXX
DOOR FRAME PAINT TRANSITION DETAIL
SCALE: 1/2" = 1'-0"
B.
PAINT EGGSHELL FINISH AT WALLS AND CEILING, SEMI-GLOSS FINISH AT DOORS/TRIM
C.
PRIOR TO POLISHING.
D.
GC REQUIREMENTS FOR CONCRETE FLOOR POLISHING:
REMOVE ALL PIPES, TUBES, BOLTS, CONDUIT, ETC. PROTRUDING FROM THE FLOOR. GC TO CUT-OUT AND PATCH FLOOR IN PREPARATION FOR POLISHING
REMOVE ALL FLOORING MATERIALS (EXCEPT MASTIC/GLUE) BEFORE POLISHING STARTS.
LARGE SURFACE REPAIR (PATCHING) USING MAPEI (800-426-2734) MAPECEM QUICKPATCH ($25/BAG). TROWEL THE MAPECEM QUICKPATCH TO A DENSE AND SMOOTH FINISH SUITABLE FOR
POLISHING. OLD REPAIRS (PATCHES) MAY NEED TO BE REMOVED AND REPLACED WITH MAPECEM QUICKPATCH FOR BETTER POLISHING RESULTS. ALL PATCHING TO COLOR MATCH EXISTING CONCRETE
TO BEST ABILITIES.
PROVIDE TEMPORARY LIGHTING, ELECTRIC, AND WATER TO JOBSITE. GC TO DISCUSS SPECIFIC REQUIREMENTS WITH FLOORING CONTRACTOR AT TIME OF SCHEDULING WORK.
E.
CONCRETE POLISHING REQUIREMENTS: 50-GRIT METAL BOND DIAMONDS ARE USED IN A WET PROCESS TO CLEAN AND SMOOTH THE CONCRETE. 100-GRIT METAL, 100-GRIT RESIN AND 200-GRIT
RESIN DIAMONDS ARE USED IN A WET PROCESS TO CREATE A UNIFORM SCRATCH PATTERN. THE CONCRETE IS CLEANED WITH WINTER BLUE CLEANER. APPLY PENETRATING CONCRETE
DENSIFIER/SEALER/HARDENER (NON-SODIUM FORMULATION) AT A COVERAGE RATE OF APPROXIMATELY 400-600 SQ. FT. PER GALLON. THE DENSIFIER OFFERS THE FOLLOWING BENEFITS:
PROVIDES A DUST PROOF SURFACE
HARDENS THE CONCRETE BY AS MUCH AS 25%
IMPROVES ABRASION RESISTANCE, MAKES THE CONCRETE STAIN RESISTANT
IMPROVES REFLECTIVITY. AFTER THOROUGHLY CLEANING
BEGIN POLISHING WITH 400-GRIT RESIN DIAMONDS
CONTROL JOINT FILLER AND ANY PATCHING TO COLOR MATCH EXISTING CONCRETE. FOLLOWED BY 800-GRIT 1500-GRIT AND 3000-GRIT RESIN DIAMONDS AS REQUIRED TO ACHIEVE A LOW, MEDIUM
AND GLOSS LEVEL AS THE MAIN FLOOR. DRAINS AND ANY OTHER SLOPED AREAS WILL BE HAND TOOLED TO BLEND WITH THE MAIN FLOOR. FACILITY CLEANLINESS WILL BE LEFT IN THE SAME OR
BETTER CONDITION THAN BEFORE COMMENCING WORK. POLISHING CONTRACTOR TO BAG ALL DUST AND DEBRIS FROM THEIR OPERATIONS AND DISPOSE PROPERLY
No.
Description
Project No.:
Drawn By:
Reviewed By:
Date
15.083.10
JA
RN
Scale:
03-11-15
Date:
Filename:
Sheet Title:
SCHEDULES
Sheet #:
A-601
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
NOTE: EXIT (CBC 1002) IS DEFINED AS "THAT PORTION OF THE MEANS OF EGRESS
SYSTEM WHICH IS SEPARATED FROM OTHER INTERIOR SPACES OF A BUILDING
OR STRUCTURE BY FIRE-RESISTANCE-RATED CONSTRUCTION AND OPENING
PROTECTIVE AS REQUIRED TO PROVIDE A PROTECTIVE PATH OF EGRESS TRAVEL
BETWEEN THE EXIT ACCESS AND THE EXIT DISCHARGE. EXITS INCLUDE EXTERIOR
EXIT DOORS AT GROUND LEVEL, EXIT ENCLOSURES, EXIT PASSAGEWAYS,
EXTERIOR ESIT STAIRS, EXTERIOR EXIT RAMPS AND HORIZONTAL EXITS.
DOORS: CBC 11B-404
NOTE: SEE ALSO 2013 CALIFORNIA ELECTRICAL CODE FOR ELECTRICAL INSTALLATION.
1. WIDTH AND HEIGHT: EVERY REQUIRED EXIT DOORWAY SHALL BE A SIZE AS TO PERMIT
THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN
6 FEET 8 INCHES IN HEIGHT. (CBC 11B-404.2.1)
1.
SWINGING DOORS SHALL PROVIDE A NET CLEAR OPENING WIDTH OF NOT LESS THAN
32 INCHES, MEASURED WITH THE DOOR OR DOORS POSITIONED AT AN ANGLE OF 90
DEGREES FROM THE CLOSED POSITION. A 34 INCH DOOR IS ACCEPTABLE. (SEE
11B-404.2).
NOTE: PUBLIC WAY (CBC 1002) IS DEFINED AS "A STREET, ALLEY OR OTHER PARCEL OF
LAND OPEN TO THE OUTSIDE AIR LEADING TO A STREET, THAT IS DEEDED,
DEDICATED, OR OTHERWISE PERMANENTLY APPROPRIATED TO THE PUBLIC FOR
PUBLIC USE AND WHICH HAS A CLEAR WIDTH AND HEIGHT OF NOT LESS THAN 10
FEET."
A NOMINAL 32 INCH CLEAR OPENING PROVIDED BY A STANDARD 6 FOOT
SLIDING PATIO DOOR ASSEMBLY IS ACCEPTABLE.(CBC 1132A.4)
NOTE: FOR THE PURPOSES OF CALIFORNIA TITLE 24, THE USE OF THE TERM "EXIT DOOR"
IN THE CALIFORNIA BUILDING CODE APPLIES TO ALL DOORS THAT PROVIDE
ACCESS, THAT IS, ENTRANCES, PASSAGE DOORS, ETC.
A PAIR OF DOORS, MANUALLY OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF WHICH
PROVIDES A CLEAR, WIDTH OF NOT LESS THAN 32 INCHES, MEASURED WITH THE DOOR
POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. (11B-404.
1.
FLOOR LEVEL AT DOORS: REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A
FLOOR OR LANDING ON EACH SIDE OF A DOOR. (CBC 11B-404.2.4.4)
ENTRANCES AND EXTERIOR GROUND FLOOR EXIT DOORS: ALL ENTRANCES AND ALL
EXTERIOR GROUND-FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE
MADE ACCESSIBLE TO PERSONS WITH DISABILITIES.SUCH ENTRANCES SHALL BE
CONNECTED BY AN ACCESSIBLE ROUTE (COMPLYING WITH SECTION 11B-206.1) AT
LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM
ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER LOADING ZONES;
PUBLIC STREETS AND SIDEWALKS ; AND PUBLIC TRANSPORTATION STOPS TO THE
ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. DOORWAYS SHALL
HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE DOOR OPEN 90
DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP.
OPENINGS MORE THAN 24 INCHES IN DEPTH SHALL COMPLY WITH CBC SECTION
11B-404 (CBC 11B-206.4)
2.
RECESSED DOORMATS: RECESSED DOORMATS SHALL BE ADEQUATELY ANCHORED
TO PREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC. (CBC 11B-302.1)
3.
GATES: ALL GATES, INCLUDING TICKET GATES, SHALL MEET ALL APPLICABLE
ACCESSIBILITY SPECIFICATIONS FOR DOORS. (CBC 11B-206.5)
4.
ed THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH
LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4
INCH AND 1/2 INCH SHALL BE BELVED WITH A SLOPE NO GREATER THAN ONE UNIT
VERTICAL TO 2 UNITS HORIZONTAL (50-PERCENT SLOPE). CHANGE IN LEVEL
GREATER THAN 1/2 INCH SHALL BE ACCOMPANIED BY MEANS OF A RAMP. SEE
SECTION 11B-405. (CBC 11B-404.2.5)
5.
THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE,
SERVING OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF
48 INCHES OF CLEAR SPACE FROM ANY DOOR OPENING INTO SUCH VESTIBULE
WHEN THE DOOR IS POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED
POSITION. DOORS IN A SERIES SHALL SWING EITHER IN THE SAME DIRECTION OR
AWAY FROM THE SPACE BETWEEN THE DOORS. SEE FIGURES 11B-30 AND 11B-31.
(CBC 11B-404.2.6)
2. THE LEVEL AREA SHALL HAVE A LENGTH IN TH DIRECTION OF DOOR SWING OF AT
LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF THE DOOR SWING
OF 48 INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE
CLOSED POSISION. (CBC 11B-404.2.4)
6.
7.
THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER
THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4 INCH
AND 1/2 INCH SHALL BE BELVED WITH A SLOPE NO GREATER THAN ONE UNIT
VERTICAL TO 2 UNITS HORIZONTAL (50-PERCENT SLOPE). CHANGE IN LEVEL
GREATER THAN 1/2 INCH SHALL BE ACCOMPANIED BY MEANS OF A RAMP. SEE
SECTION 11B-405. (CBC 11B-404.2.5)
THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE,
SERVING OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF
48 INCHES OF CLEAR SPACE FROM ANY DOOR OPENING INTO SUCH VESTIBULE
WHEN THE DOOR IS POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED
POSITION. DOORS IN A SERIES SHALL SWING EITHER IN THE SAME DIRECTION OR
AWAY FROM THE SPACE BETWEEN THE DOORS. SEE FIGURES 11B-30 AND 11B-31.
(CBC 11B-404.2.6)
1.
IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON
LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS,
PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. (CBC 11B-206 & 11B-302)
2.
THE SURFACE OF FLOORS SHALL BE SLIP-RESISTANT AND SHALL COMPLY WITH CBC
SECTION 11B-302. (CBC 11B-302.1)
CHANGES IN LEVEL UP TO 1/4 INCH VERTICAL AND WITHOUT EDGE TREATMENT (SEE
CBC FIG. 11B-5E(c) AND (d)). CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH
SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH CBC FIGURE
11B-5E(d). (CBC 11B-303)
5.
IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, IT SHALL
BE SECURELY ATTACHED; HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION
OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP; LEVEL-CUT PILE, OR
LEVEL-CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2 INCH.
EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE
TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM
SHALL COMPLY WITH CBC SECTION 11B-302.2.
(CBC 11B-302.2)
7.
LOCKS AND LATCHES: LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT
OPERATION OF DOORS WHERE ANY OF THE FOLLOWING EXISTS:
1. PLACES OF DETENTION OR RESTRAINT.
2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT LOAD OF 300 OR LESS,
GROUPS B, F, M, AND S, AND IN PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR
DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED LOCKING
DEVICES FROM THE EGRESS SIDE PROVIDED:
2.1 THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED,
2.2 A READILY VISIBLE DURABLE SIGN IS POSTED ON THE DEGREE SIDE ON OR
ADJACENT TO THE DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN
BUILDING IS OCCUPIED." THE SIGN SHALL BE IN LETTERS 1 INCH HIGH ON A
CONTRACTING BACKGROUND.
2.3 THE USE OF A KEY-OPERATED LOCKING DEVICE IS REVOCABLE BY THE BUILDING
OFFICIAL FOR DUE CAUSE.
3. WHERE EGRESS DOORS ARE USED IN PAIRS, APPROVED AUTOMATIC FLUSH BOLTS
SHALL BE PERMITTED TO BE USED, PROVIDED THAT THE DOOR LEAF HAVING THE
AUTOMATIC FLUSH BOLTS HAS NO DOORKNOB OR SUFACE-MOUNTED HARDWARE.
4. DOORS FROM INDIVIDUAL DWELLING OR SLEEPING UNITS OF GROUP R OCCUPANCIES
HAVING AN OCCUPANT LOAD OF 10 OR LESS ARE PERMITTED TO BE EQUIPPED WITH
A NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, PROVIDED SUCH DEVICES ARE
OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR TOOL.
BOLT LOCKS: MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
PERMITTED. (CBC 1008.1.9.4)
UNLATCHING: THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE
THAN ONE OPERATION. (CBC 1008.1.9.5)
DELAYED EGRESS LOCKS: APPROVED, LISTED, DELAYED EGRESS LOCKS SHALL BE
PERMITTED TO BE INSTALLED ON DOORS SERVING ANY OCCUPANCY EXCEPT GROUP A,
E, AND H OCCUPANCIES IN BUILDING THAT ARE THROUGHOUT WITH AN AUTOMATIC
SPRINKLER IN ACCORDANCE WITH CBC SECTION 903.2.17.1 AND AN APPROVED
AUTOMATIC SMOKE DETECTATION SYSTEM INSTALLED IN ACCORDANCE WITH SECTION
907, PROVIDED THAT THE DOORS UNLOCK IN ACCORDANCE WITH ITEMS 1 THROUGH 9
BELOW. A BUILDING OCCUPANT SHALL NOT BE REQUIRED TO PASS THROUGH MORE
THAN ONE DOOR EQUIPPED WITH A DELAYED EGRESS LOCK BEFORE ENTERING AN EXIT.
1. THE DOORS UNLOCK ACTUATION OF THE AUTOMATIC SPRINKLER SYSTEM OF
AUTOMATIC SMOKE DETECTION SYSTEM.
2. THE DOORS UNLOCK UPON LOSS OF ELECTRICAL POWER TO ANY ONE OF THE
FOLLOWING:
2.1 THE EGRESS-CONTROL DEVICE ITSELF;
2.2 THE SMOKE DETECTION SYSTEM; AND
2.3 MEANS OF EGRESS ILLUMINATION AS REQUIRED BY SECTION 1006.
3. THE DOOR LOCKS SHALL HAVE THE CAPABILITY OF BEING UNLOCKED BY A SIGNAL
FROM A SWITCH LOCATED IN AN APPROVED LOCATION.
4. THE INITIATION OF AN IRREVERSIBLE PROCESS WHICH WILL RELEASE THE LATCH IN
NOT MORE THAN 15 SECONDS WHEN A FORCE IF NOT MORE THAN 15 POUNDS IS
APPLIED FOR 1 SECOND TO THE RELEASE DEVICE. INITIATION OF THE IRREVERSIBLE
PROCESS SHALL ACTIVATE AN AUDIBLE SIGNAL IN THE VICINITY OF THE DOOR. ONCE
THE DOOR LOCK HAS BEEN RELEASED BY THE APPLICATION OF FORCE TO THE
RELEASING DEVICE, RELOCKING SHALL BE BY MANUAL MEANS ONLY. (SFM) THE TIME
DELAY ESTABLISHED FOR EACH EGRESS-CONTROL DEVICE SHALL NOT BE FIELD
ADJUSTABLE.
CLEAR FLOOR SPACE: CLEAR FLOOR SPACE COMPLYING WITH CBC SECTION
11B-305 THAT ALLOWS A FORWARD OR PARALLEL APPROACH BY A PERSON USING A
WHEELCHAIR SHALL BE PROVIDED AT CONTROLS, DISPENSERS, RECEPTACLES AND
OTHER OPERABLE EQUIPMENT. (CBC 11B-309.2)
4.
HEIGHT: THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS,
RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN AT
LEAST ONE OF THE REACH RANGES SPECIFIED IN CBC SECTIONS 11B-308.2 AND
11B-308.3. ELECTRICAL AND COMMUNICATION SYSTEMS RECEPTACLES ON WALLS
SHALL BE MOUNTED NO LESS THAN 15 INCHES ABOVE THE FLOOR.
(CBC 11B-309.3)
5.
OPERATION: CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH
ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PUNCHING OR TWISTING OF
THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER
THAN 5 POUNDS OF FORCE. (CBC 11B-309.4)
6.
FORWARD REACH: IF THE CLEAR FLOOR SPACE ALLOWS ONLY FORWARD
APPROACH TO AN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL
BE 48 INCHES (SEE CBC FIGURE 11B-5C(a)). THE MINIMUM LOW FORWARD REACH IS
15 INCHES. IF THE HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH AND
CLEARANCES SHALL BE AS SHOWN IN CBC FIGURE 11B-5C(b). (CBC 11B-704.2.1.2)
7.
SIDE REACH: IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A
PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED SHALL BE 48
INCHES AND THE LOW SIDE REACH SHALL BE NO LESS THAN 15 INCHES ABOVE THE
FLOOR (SEE CBC FIGURE 11B-308.3.1. IF THE SIDE REACH IS OVER AN OBSTRUCTION,
THE REACH AND CLEARANCES SHALL BE AS SHOWN IN FIGURE 11B-308.3.2 (a) & (b)
(CBC 11B-308.3.2)
GENERAL
BUILDING PERMIT/ FEES
OTHER PERMITS, FEES, INSURANCE
TRASH REMOVAL & DUMPSTER
CONCRETE SLAB - STRUCTURAL
TEMPORARY BARRICADES
TEMPORARY WINDOW GRAPHICS
CLEAN-UP & FINAL CLEANING
REMARKS
INCLUDING NEW DUMPSTER FOR OPS TRUCK
STOREFRONT
DEMOLITION
STOREFRONT STEEL & CONNECTIONS
STOREFRONT DOORS AND HARDWARE
STOREFRONT GLAZING CHANNELS
STOREFRONT GLASS
FIRE RATED WOOD BLOCKING
FRAMING & SHEATHING
STOREFRONT SIGNAGE
STOREFRONT SIGNAGE FIRE RATED BLOCKING
STOREFRONT WINDOW FILM (WF-1, WF-4, WF-7)
STOREFRONT FACADE/RAISED PARAPET
GENERAL CONSTRUCTION
DEMOLITION
TRENCHING OF EXISTING SLAB
DEMISING PARTITION STUDS
DEMISING PARTITION GYP. BD.
CARPENTRY, ROUGH, & FINISH
BLOCKING & METAL STRAPPING
INTERIOR PARTITION GYP. BD., METAL STUDS, FURRING, ETC.
GYPSUM BOARD CEILING & APPLICABLE FRAMING/ SUSPENSION
CORNER GUARDS
CEILING ACCESS PANELS
DOORS & FRAMES (EXCEPT FITTING ROOMS)
DOOR HARDWARE (EXCEPT FITTING ROOMS)
FITTING ROOM DOORS, FRAMES, TRIM & HARDWARE
SALES AREA & FITTING ROOM MIRRORS & MASTICS
MOISTURE TEST - FLOOR
REDUCER STRIP ADHESIVES, ETC.
FLOOR TRANSITION STRIPS
SCHLUTER FLOOR TRANSITION STRIP
TOILET ACCESSORIES
BOTTLED WATER DISPENSER
FIRE EXTINGUISHERS
A.D.A. SIGN(S) @ TOILET ROOM(S)
A.D.A. SIGN(S) @ ACCESSIBLE FITTING ROOM
PAINTING
Seal:
ELECTRICAL SERVICE BY LL EC, SIGN(S) BY TENANT VENDOR.
A Project for:
WITHIN 3 DAYS OF THE COMPLETION OF DEMOLITION
TOILET ROOM(S) ONLY
MALL TILE FLOORING & GROUT
WALL COVERINGS
WALL GRAPHICS
WALL BASE (WB1, WB2)
WALL TRIM (WT-1, WT-2)
WALL PANEL (WP-1)
WOOD END CAP (WD-X)
CONCRETE FINISH (CF-1)
CONCRETE FINISH (CF-2)
FLOOR PREPARATION; INCLUDING FLOATING IF NECESSARY
FLOOR PROTECTION; INCLUDING CLEANING/ SEALING/ WAXING
GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE
ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB
RAMPS, SHALL BE STABLE, FIRM, AND SLIP-RESISTANT, AND SHALL COMPLY WITH
CBC SECTION 11B-302. (CBC 11B-302)
4.
(REFER TO ADA DETAIL SHEETS)
HARDWARE HEIGHT: DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING
DEVICES SHALL BE INSTALLED 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE
THE FINISHED FLOOR. LOCKS USED ONLY FOR SECURITY PURPOSES AND NOT USED FOR
NORMAL OPERATION ARE PERMITTED AT ANY HEIGHT. (CBC 1008.1.9.2)
3.
(REFER TO ADA DETAIL SHEETS)
6.
HARDWARE: DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING
DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11A OR CHAPTER 11B
SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST
TO OPERATE. (CBC 1008.1.9.1)
GENERAL: CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES,
ALONG ACCESSIBLE ROUTES OR AS PARTS OF ACCESSIBLE ELEMENTS (FOR
EXAMPLE, LIGHT SWITCHES AND DISPENSER CONTROLS) AN THOSE REQUIRED TO
BE ACCESSIBLE BY CBC SECTION 109.1 SHALL COMPLY WITH THE REQUIREMENTS
OF THIS SECTION. (CBC 11B-205)
FLOORS & LEVELS
DOORS
DOOR OPERATIONS: EXCEPT AS SPECIFICALLY PERMITTED BY THIS SECTION EGRESS
DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A
KEY OR SPECIAL KNOWLEDGE OR EFFORT. (CBC 1008.1.9)
2.
3. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL
EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOOR AND
18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS. (CBC 11B-404.2.4)
NOTE: LEVEL AREA IS DEFINED AS "A SPECIFIED SURFACE THAT DOES NOT HAVE A
SLOPE IN ANY DIRECTION EXCEEDING 1/4 INCH IN 1 FOOT FROM THE
HORIZONTAL (2.083% GRADIENT)." (CBC 11B-302)
SPACES FOR VENDING MACHINES AND OTHER EQUIPMENT SHALL COMPLY WITH
CBC SECTION 1118B AND SHALL BE LOCATED ON AN ACCESSIBLE ROUTE
COMPLYING WITH SECTION 11B-206. CONTROLS FOR VENDING MACHINES AND
OTHER EQUIPMENT SHALL COMPLY WITH CBC SECTION 11B-205, CONTROLS AND
OPERATING MECHANISMS. (CBC 11B-228)
CONTROLS AND OPERATING MECHANISMS (11B-205)
WIDE
1. MANEUVERING CLEARANCES AT DOORS: MINIMUM CLEARANCES AT DOORS SHALL BE
SHOWN IN FIGURES 11B-26A AND 11B-26B. THE FLOOR OR GROUND AREA WITHIN THE
REQUIRED CLEARANCES SHALL BE LEVEL AND CLEAR. (CBC 11B-404.2.5)
3.
RESPONSIBILITY SCHEDULE
GC TO PAINT TRIM PT-8
FIXTURES
FIXTURE PACKAGE
WALL STANDARDS
WALL STANDARD MOUNTING HARDWARE (WALL TOGGLES/TOGGLE
WALL MOUNTED SLATWALL (SW-X)
BOLTS)
CASHWRAP & BACKWRAP
CASH REGISTERS & EQUIPMENT
FREE STANDING FIXTURES
FITTING ROOM ACCESSORIES
FITTING ROOM BENCHES
FITTING ROOM GRAB BAR
VISUAL FIXTURE/ MANNEQUINS, ETC.
SPIDER DISPLAY TRACKS & GRAPHIC BANNER TRACKS
CEILING ELEMENTS
SUSPENDED CEILING ELEMENTS
SUSPENDED CEILING ELEMENTS MOUNTING
FLEXIBLE
MESH
HARDWARE
FLEXIBLE MESH MOUNTING HARDWARE
MANAGERS DESK & SAFE
ALL NON-SALES SHELVING
RESTROOM SHELVING
REFRIGERATOR
MICROWAVE
STORE FIXTURES - REFER TO FIXTURE LEGEND ON
STOCKROOM
EQUIPMENT - REFER TO FIXTURE LEGEND ON SHEET
SHEET A2
A2
IF GRATINGS ARE LOCATED WALKING SURFACES, THEN THEY SHALL HAVE SPACES
NO GREATER THAN 1/2" WIDE IN ONE DIRECTION (SEE CBC FIG. 11B-7B). IF GRATINGS
HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE LONG
DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL (SEE CBC
FIG. 118-7B). (CBC 11B-302.4)
HAZARDS
1. WARNING CURBS: ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK OR
SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY, EXCEEDING 4 INCHES IN A
VERTICAL DIMENSION, SUCH AS AT PLANTERS OR FOUNTAINS LOCATED IN OR
ADJACENT TO WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS, SHALL BE
IDENTIFIED BY CURBS PROJECTING AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK
OR SIDEWALK SURFACE TO WARN THE BLIND OF A POTENTIAL DROP OFF.
MECHANICAL - REFER TO MECHANICAL SHEETS FOR ADDITIONAL INFORMATION
HVAC UNITS
ROOF WORK
HVAC UNIT CURB
HVAC DISTRIBUTION - DUCTWORK, DIFFUSERS, ETC.
AIR BALANCING
EXHAUST FAN/ LIGHT COMBO
EXHAUST DUCTWORK
RETURN AIR GRILLES
HVAC SERVICE CALLS
HVAC FILTER CHANGE
DUCT SMOKE DETECTION
SMOKE EVACUATION SYSTEM
FIRE SPRINKLER SHUT-OFF
TRANSFER GRILLE FIRE DAMPERS
SPRINKLER SYSTEM MODIFICATION
PLUMBING FIXTURES (H.C. ACCESSIBLE)
HI-LO WATER COOLER WITH ADA APRON
WATER & SEWER STUB-INS
WATER & SEWER PIPING
PROGRAMMABLE THERMOSTAT
SPACE HEATER
WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED, NO CURB IS REQUIRED WHEN A
GUIDE RAIL IS PROVIDED CENTERED 3 INCHES PLUS OR MINUS 1 INCH ABOVE THE
SURFACE OF THE WALK OR SIDEWALK, THE WALK IS 5 PERCENT OR LESS GRADIENT,
OR NO ADJACENT HAZARD EXISTS.
2. OVERHANGING OBSTRUCTIONS: ANY OBSTRUCTION THAT OVERHANGS A
PEDESTRIAN'S WAY SHALL BE A MINIMUM OF 80 INCHES ABOVE THE WALKING
SURFACE AS MEASURED FROM THE BOTTOM OF THE OBSTRUCTION. WHERE A GUY
SUPPORT IS USED PARALLEL TO A PATH OF TRAVEL, INCLUDING, BUT NOT LIMITED TO
, SIDEWALKS, A GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO
PREVENT AN OVERHANGING OBSTRUCTION AS DEFINED. (CBC 11B-307.4, FIG 11B-28)
3. DETECTABLE WARNINGS AT HAZARDOUS VEHICULAR AREAS: IF A WALK CROSSES OR
ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY
CURBS, RAILINGS, OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND
VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A
CONTINUOUS DETECTABLE WARNING WHICH IS 36 INCHES WIDE, COMPLYING WITH
CBC SECTIONS 11B-705.1.2.5,
ELECTRICAL - REFER TO ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION
METER SOCKET
ELECTRICAL SERVICE
TRANSFORMER
ELECTRICAL PANELS
WIRING, CIRCUITING, RECEPTACLES, SWITCHES, ETC.
CONNECTION & WIRING OF CASHWRAP/ BACKWRAP
LIGHTING CONTROL SYSTEM/ LOAD LIMITER SYSTEM
NIGHT LIGHTS
OCCUPANCY SENSORS
EMERGENCY LIGHTING
LIGHT FIXTURES, TRACK & LAMPS (TENANT PROVIDED)
LIGHT FIXTURES/HI-BAYS & LAMPS (LL PROVIDED)
EXIT SIGNS
FIRE ALARM
TELEPHONE SYSTEM
TELECOM/DATA LINE
TELECOM/DATA SURVEY
TELEPHONE, P.O.S. SYSTEM CONDUIT
P.O.S. SYSTEM
PANEL ALARM DEVICE @ REAR DOOR
DOOR BUZZER
DOOR BUZZER CONTACT
THEFT PREVENTION SYSTEM (*SEE NOTE #2 BELOW)
POWER AND ELECTRICAL TO THEFT PREVENTION
SOUND
SYSTEMSYSTEM
SIGN WHIP(S)
SIGN TIME SWITCH
LOW VOLTAGE WIRING (PLENUM RATED) or (WITHIN CONDUIT)
ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL
SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF
REGULATIONS (CCR), TITLE 24, PART 1, ARTICLES 2, 3, AND 4. REFER TO CCR TITLE 24,
PART 12, CHAPTERS 12-11A AND B, FOR BUILDING AND FACILITY ACCESS
SPECIFICATIONS FOR PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS
AND DIRECTIONAL SURFACES.
DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES INSTALLED AFTER
JANUARY 1, 2001, SHALL BE EVALUATED BY AN INDEPENDENT ENTITY, SELECTED BY
THE DEPARTMENT OF GENERAL SERVICES, DIVISION OF THE STATE
ARCHITECT--ACCESS COMPLIANCE, FOR ALL OCCUPANCIES, INCLUDING
TRANSPORTATION AND OTHER OUTDOOR ENVIRONMENTS, EXCEPT THAT WHEN
PRODUCTS AND SURFACES ARE FOR USED IN RESIDENTIAL HOUSING, EVALUATION
SHALL BE IN CONSULTATION WITH THE DEPARTMENT OF HOUSING AND COMMUNITY
DEVELOPMENT. (SEE GOVERNMENT CODE SECTION 4460).
PROTRUDING OBJECTS (CBC 11B-204 & 11B-307)
1. GENERAL: OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES), WITH
THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 INCHES ABOVE THE FINISHED
FLOOR, SHALL PROTRUDE NO MORE THAN 4 INCHES INTO WALKS, HALLS,
CORRIDORS, PASSAGEWAYS OR AISLES. OBJECTS MOUNTED WITH THEIR LEADING
EDGES AT OR BELOW 27 INCHES ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY
AMOUNT. FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY
OVERHANG 12 INCHES MAXIMUM FROM 27 INCHES TO 80 INCHES ABOVE THE
GROUND OR FINISHED FLOOR. PROTRUDING OBJECTS SHALL NOT REDUCE THE
CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. (CBC 11B-307.2,
FIG. 11B-307.2)
FIXTURE PACKAGE
FIXTURE PACKAGE
FIXTURE PACKAGE
FIXTURE PACKAGE
FIXTURE PACKAGE
SECURITY DOME, WIFI MOUNT. SEE DETAILS ON A4 FOR RESPONSIBILITY
SPECIFICS
FABRIC TUBE, LAMP SHADE, ETC! EXCLAMATION POINT. SEE DETAILS ON A4.1 FOR RESPONSIBILITY
SPECIFICS
FIXTURE PACKAGE
FIXTURE PACKAGE
PROVIDE NEW HVAC UNITS AT 1 TON PER 325 SF FULLY OPERATIONAL AT
TURNOVER
NEW AT TURNOVER
AS REQUIRED BY LOCAL ENFORCEMENT
2580 BELL ROAD
AUBURN, CA 95603
(REFER TO ADA DETAIL SHEETS) cont.
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
(REFER TO ADA DETAIL SHEETS)
CONTROLS & OPERATING MECHANISMS
TENANT IMPROVEMENT
DOORS
EXISTING
NOT APPLICABLE
FURNISH
INSTALL
FURNISH TENANT
INSTALL VENDOR
FURNISH
INSTALL
ENTRANCES, EXITS & PATHS OF TRAVEL
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
FIXTURES 'C', 'D', 'E', 'H' AND 'TR' PROVIDED BY TENANT VENDOR
ALL OTHER FIXTURES PROVIDED BY LL
Revisions:
TERMINATION BY VENDOR, SEE ELECTRICAL PLANS FOR ADDITIONAL
INFORMATION
GENERAL RESPONSIBILITY NOTE(S):
1. ANY WORK REQUIRED FOR CONSTRUCTION NOT NOTED ON PLANS TO BE GC'S RESPONSIBILITY.
2. GC WILL BE RESPONSIBLE TO CONTACT FALCON DURING THE FIRST WEEK OF CONSTRUCTION TO SCHEDULE A SITE VISIT BY A FALCON TECHNICIAN. THE
TECHNICIAN WILL AT THAT TIME, PERFORM A TEST TO DETERMINE THE CAPABILITY OF THE SECURITY SYSTEM WITH THE EXISTING CONDITIONS.
2. HEAD ROOM: WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES, OR OTHER
CIRCULATION SPACES SHALL HAVE 80 INCHES MINIMUM CLEAR HEAD ROOM. IF
VERTICAL CLEARANCE OF AN AREA ADJOINING AN ACCESSIBLE ROUTE IS REDUCED
TO LESS THAN 80 INCHES (NOMINAL DIMENSION), A BARRIER TO WARN BLIND OR
GRAPHICS/CEILING ELEMENTS
MICHAEL LEVY
PERSPECTIVES INPRINT
3005 VENTURE COURT
EXPORT, PA 15632
mikelevy1@me.com
(724) 325-1882 X23
(724) 325-1895 (FAX)
3. FREE-STANDING SIGNS: WHENEVER SIGNS MOUNTED ON POSTS OR PYLONS
PROTRUDE FROM THE POSTS OR PYLONS AND THE BOTTOM EDGE OF THE SIGN IS
LESS THAN 80 INCHES ABOVE THE FINISHED FLOOR OR GROUND LEVEL, THE EDGES
OF SUCH SIGNS SHALL BE ROUNDED OR EASED AND THE CORNERS SHALL HAVE A
WALLCOVERINGS
KOROSEAL/RJF INTERNATIONAL
CORPORATION
MICHELLE GROSS
(866) 628-2280
(330) 664-2152 (FAX)
5. A SIGN SHALL BE PROVIDED ON THE DOOR LOCATED ABOVE AND WITHIN 12 INCHES
OF THE RELEASE DEVICE READING: "KEEP PUSHING. THIS DOOR WILL OPEN IN 15 [30]
SECONDS. ALARM WILL SOUND." SIGN LETTERING SHALL BE AT LEAST 1 INCH IN
HEIGHT AND SHALL HAVE A STROKE OF NOT LESS THAN 1/8 INCH.
FLEXIBLE MESH
JUDITH VON HOPF, INC.
customerservice@judithvonhopf.com
8750 PRESTIGE COURT
RANCHO CUCAMONGA, CA
91730
(909) 481-1884
5.1 A TACTILE SIGN SHALL ALSO BE PROVIDED IN BRAILLE AND RAISED CHARACTERS,
WHICH COMPLIES WITH CHAPTER 11B, SECTION 11B-703.1, 11B-703.2, 11B-703.3, &
11B-703.5
6. EMERGENCY LIGHTING WILL BE PROVIDED AT THE DOOR.
LIGHTING
CITY LIGHTING
KEVIN RAPE
krape@citylighting.com
800-257-2922 X321
(412) 366-7609 (FAX)
SIGN VENDOR
CHANDLER SIGNS
LAURA BERJON
lberjon@chandlersigns.com
(210) 349-3804 x6631
TELECOM
WARNER TELECOM
DAVID KELLY
(412) 760-8570
MUSIC SYSTEM
PLAY NETWORK
KIRA LITCHENFELD
klitchenfeld@playnetwork.com
(425) 629-2793
(425) 497-8181 (FAX)
LEVEL 10 POS
KATY SCHRAMM
kschramm@level10.com
(847) 805-9094
7. ACTUATION OF THE PANIC BAR OR OTHER DOOR-LATCHING HARDWARE SHALL
ACTIVATE AN AUDIBLE SIGNAL AT THE DOOR.
SECURITY SYSTEM
VECTOR SECURITY
MARCUS EDDY
meddy@vectorsecurity.com
(703) 468-6100 X51250
THEFT PREVENTION SYSTEM
FALCON
USS
KEVIN HUTCHERSON
khutcherson@universaleas.com
909-855-8140
909-484-7874 (FAX)
MILLWORK/FITTING ROOMS
ICS
CHARLIE CAPLAN
charlie@icsww.com
(440) 463-7826 (CELL)
(440) 951-9919
(440) 951-6978 (FAX)
PREFERRED DOOR, FRAME,
HARDWARE
LOCKNET
ROB OWEN
construction@locknet.com
(800) 887-4307
WALL STANDARDS
OMAHA FIXTURES
BARB UHRMACHER
barb.uhrmacher@omahafixture.com
(402) 593-5713
No.
Description
Project No.:
Drawn By:
Reviewed By:
Scale:
WOOD END CAP
TIMELINE
MATT STROUD
matt@timelinewood.com
544 MATEO STREET
LOS ANGLES, CA 90013
(213) 620-5730
(213) 361-3161 (CELL)
Date:
Filename:
Sheet Title:
GENERAL
NOTES
PREFERRED STOREFRONT
VENDOR
AMERICAN PRODUCTS, INC. (API)
NATHAN SHERMAN
nsherman@americanprod.com
(813) 925-0144
8. THE UNLATCHING SHALL NOT REQUIRE MORE THAN ONE OPERATION.
Date
15.083.10
JA
RN
AS NOTED
03-11-15
--
Sheet #:
9. REGARDLESS OF THE MEANS OF DEACTIVATION, RELOCKING OF THE
EGRESS-CONTROL SHALL BE BY MANUAL MEANS ONLY AT THE DOOR.
G-102
GC TO CONTACT RUE21 PRIOR TO START OF CONSTRUCTION TO CONFIRM VENDOR SUPPLIERS, INSTALLATION AND SCHEDULE
GENERAL NOTES
TENANT SUGGESTED RESOURCES
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
2.
ACCESSIBLE WATER CLOSETS: THE HEIGHT OF ACCESSIBLE WATER CLOSETS
SHALL BE A MINIMUM OF 17 INCHES AND A MAXIMUM OF 19 INCHES MEASURED TO
THE TOP OF A MAXIMUM 2 INCH HIGH TOILET SEAT. EXCEPTION: A 3 INCH SEATS
SHALL BE PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS
THAN 15 INCHES HIGH. (CBC 1115B.4.4.1)
WATER CLOSET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS FOR
THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS, NO
MORE THAN 44" ABOVE THE FLOOR.
(SEE DETAIL SHEET GA-501)
NOTE: SIGNS AND IDENTIFICATION: CALIFORNIA'S STANDARDS FOR SIGNAGE ARE MORE
STRINGENT AND ARE SIGNIFICANTLY LARGER AND WIDER THAN FEDERAL LAW,
AMERICANS WITH DISABILITIES ACT (ADA) SECTION 4.30. (CBC 11B-703)
1.
2.
THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF.
ELECTRONIC AUTOMATIC FLUSHING CONTROLS ARE ACCEPTABLE AND
3.
4.
MIRRORS: MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN
40 INCHES FROM THE FLOOR. (CBC 1115B.8.1)
5.
MEDICINE CABINETS: IF MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL
BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES THE FLOOR. A
CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES BY COMPLYING WITH SECTION
1118B.4 SHALL BE PROVIDED IN FRONT OF A MEDICINE CABINET TO ALLOW
FORWARD OR PARALLEL APPROACH. (CBC 1115B.8.2)
5.
6.
7.
8.
9.
TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, DISPENSERS AND CONTROLS:
WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, AND OTHER SIMILAR
DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE
SHALL BE LOCATED ON AN ACCESSIBLE ROUTE, WITH ALL OPERABLE PARTS,
INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FINISHED FLOOR. (CBC
1115B.8.3)
TOILET TISSUE DISPENSERS: TOILET TISSUE DISPENSERS SHALL BE LOCATED ON
THE WALL WITHIN 12 INCHES OF THE FRONT EDGE OF THE TOILET SEAT (AND NO
LOWER THAN 19 INCHES FROM THE FLOOR). DISPENSERS THAT CONTROL DELIVERY
OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. (CBC
WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE
30 INCHES BY 48 INCHES IN FRONT OF THE URINAL TO ALLOW FORWARD APPROACH.
THIS CLEAR SPACE SHALL COMPLY WITH CB SECTION 1118B.4. (CBC 1115B.4.2.3)
4.
5.
7.
8.
9
10. URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST AND SHALL BE
MOUNTED NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO
ACTIVATE CONTROLS SHALL BE NO MORE THAN 5 LBF ELECTRONIC AUTOMATIC
11. FLUSH CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE
HAND IN ACCORDANCE WITH CB CHAPTER 11B AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST AND SHALL BE MOUNTED NO
MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE
CONTROLS SHALL BE NO MORE THAN 5 BF. LEVER-OPERATED, PUSH-TYPE AND
ELECTRONICALLY CONTROLLED MECHANISMS (PREFERABLE) ARE EXAMPLES OF
ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET
12. LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE
A MINIMUM OF 18 INCHES TO THE CENTER LINE OF THE FIXTURE.
ALL LAVATORIES THAT ARE DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM
17 INCHES IN THE HORIZONTAL DEPTH AND MOUNTED WITH THE RIM OR COUNTER
EDGE NO HIGHER THAN 34 INCHES ABOVE THE FINISHED FLOOR AND WITH A
VERTICAL CLEARANCE MEASURED FROM THE BOTTOM OF THE APRON OR OUTSIDE
BOTTOM EDGE OF THE LAVATORY OF 29 INCHES REDUCING TO 27 INCHES AT A
POINT LOCATED 8 INCHES BACK FROM THE FRONT EDGE. IN ADDITION, A MINIMUM
OF 9-INCH-HIGH TOE CLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD
THE WALL TO A DISTANCE NO MORE THAN 6 INCHES FROM THE BACK WALL. THE
TOE CLEARANCE SPACE MUST BE FREE OF EQUIPMENT OR OBSTRUCTIONS. (CBC
1115B.4.3.2 FIG.11-B)
13. KNEE CLEARANCE THAT IS AT LEAST 27 INCHES HIGH, 30 INCHES WIDE AND 19
INCHES DEEP SHALL BE PROVIDED UNDERNEATH SINKS. (CBC 1115B.4.7.1, FIG.
11B-1D)
14. HOT WATER AND DRAINPIPES EXPOSED UNDER SINKS SHALL BE INSULATED OR
OTHERWISE CONFIGURED SO AS TO PROTECT AGAINST CONTACT. THERE SHALL BE
NO SHARP OR ABRASIVE SURFACES UNDER SINKS. (CBC 1115B.4.7)
15. TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE
SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC TILE OR OTHER APPROVED
MATERIAL WHICH EXTENDS UPWARD ONTO THE WALLS AT LEAST 5 INCHES. WALLS
WITHIN WATER CLOSET COMPARTMENTS AND WALLS WITHIN 24 INCHES OF THE
FRONT AND SIDES OF URINALS SHALL BE SIMILARLY FINISHED TO A HEIGHT OF 48
INCHES AND, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH
WALLS SHALL BE A TYPE WHICH IS NOT ADVERSELY AFFECTED BY MOISTURE. (CBC
1115B.3.2.5)
COLOR OF SYMBOL: THE INTERNATIONAL SYMBOL OF ACCESSIBILITY ABOVE SHALL
CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL
TO COLOR NO. 15090 IN FEDERAL STANDARD 595B. (CBC 11B-703.7.2.1)
ENTRANCE SIGNS: ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND
USABLE BY PERSONS WITH DISABILITIES SHALL BE IDENTIFIED WITH A MINIMUM OF
ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL
DIRECTIONAL SIGNS, UTILIZING THE SYMBOL, AT JUNCTIONS, TO BE VISIBLE TO
PERSONS ALONG APPROACHING PEDESTRIAN WAYS. (CBC 11B-216.6)
INTERNATIONAL TTY SYMBOL: WHERE THE INTERNATIONAL TTY SYMBOL IS
REQUIRED, IT SHALL COMPLY FIGURE CD-30FB. (CBC 11B-703.7.2.2)
SIGNS FOR TEXT TELEPHONES: WHENEVER SIGNS SHALL REFER TO TEXT
TELEPHONES FOR PEOPLE WHO ARE DEAF OR HARD OF HEARING, THE TERM "TTY"
SHALL BE USED. (CBC 11B-703.7.2.2)
MOUNTING LOCATION AND HEIGHT: WHERE PERMANENT IDENTIFICATION IS
PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL
ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL
SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE
PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. (CBC
11B-703.4.1)
HEIGHT: MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISHED FLOOR TO
THE CENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO
THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT
ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A
DOOR. (CBC 11B-703.4.2)
IDENTIFICATION SIGNS: WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES
OF A BUILDING OR SITE, THEY SHALL COMPLY WITH CBC SECTIONS 11B-703.2.4,
11B-703.2, 11B-703.2.3 AND 11B-703.4.1. (CBC 11B-703)
CLEAR SPACE AT FIXTURES: DOORS SHALL NOT SWING SHALL INTO THE FLOOR
SPACE REQUIRED FOR ANY FIXTURE. (CBC 1115B.3.2.2)
URINALS SHALL BE FLOOR MOUNTED STALL-TYPE OR WALL HUNG. WHERE ONE OR
MORE WALL HUNG URINALS ARE PROVIDED, AT LEAST ONE WITH A ELONGATED RIM
PROJECTING A MINIMUM OF 14 INCHES FROM THE WALL AND AT A MAXIMUM OF 17
INCHES ABOVE THE FLOOR SHALL BE PROVIDED. (CBC 1115B.4.2.1)
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY: THE INTERNATIONAL SYMBOL OF
ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE
ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN
THIS BUILDING STANDARDS AND AS SPECIFICALLY REQUIRED IN THIS SECTION. SEE
FIGURE CD-30FA. (CBC 11B-703.7.2.1)
10. DIRECTIONAL AND INFORMATIONAL SIGNS: WHEN SIGNS DIRECT TO OR GIVE
INFORMATION ABOUT PERMANENT ROOMS AND SPACE OF A BUILDING OR SITE,
THEY SHALL COMPLY WITH CBC SECTIONS 11B-703.5.1, 11B-703.5.2.4 AND
11B-703.5.4. (CBC 11B-703)
11. ACCESSIBILITY SIGNS: WHEN SIGNS IDENTIFY, DIRECT OR GIVE INFORMATION
ABOUT ACCESSIBLE ELEMENTS AND FEATURES OF A BUILDING OR SITE, THEY
SHALL INCLUDE THE APPROPRIATE SYMBOL OF ACCESSIBILITY AND SHALL COMPLY
WITH CBC SECTION 11B-703.5.1 AND, WHEN APPLICABLE, CBC SECTION 11B-703.7.2.
(CBC 11B-703)
12. FINISH AND CONTRAST: CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL
HAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH
THEIR BACKGROUND, EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR
DARK CHARACTERS ON A LIGHT BACKGROUND. (CBC 11B-703.5.1)
13. PROPORTIONS: CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF
BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND
1:10. (CBC 11B-703.2.4)
14. CHARACTER HEIGHT: CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED
ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE
MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE X. LOWERCASE
CHARACTERS ARE PERMITTED. FOR SIGNS SUSPENDED OR PROJECTED ABOVE THE
FINISH FLOOR IN COMPLIANCE WITH CBC SECTION 1133B.8.6, THE MINIMUM
CHARACTER HEIGHT SHALL BE 3 INCHES. (CBC 11B-703.5.4)
15. RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS: WHEN RAISED CHARACTERS
ARE REQUIRED OR WHEN PICTORIAL SYMBOLS (PICTOGRAMS) ARE USED ON SUCH
SIGNS, THEY SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: (CBC 11B-703.2)
A.
CHARACTERS ON SIGNS SHALL BE RAISED OR RECESSED 1/32 INCH MINIMUM AND
SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2
B.
RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8 INCH AND A
MAXIMUM OF 2 INCHES HIGH. (CBC 11B-703.2)
C.
PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE VERBAL
DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE
DIMENSION OF THE PICTOGRAM FIELD SHALL BE A MINIMUM OF 6 INCHES IN
HEIGHT. (CBC 11B-703.6)
D.
CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT. BRAILLE SHALL BE
PLACED A MINIMUM OF 1/8 INCH AND A MAXIMUM OF 1/2 INCH DIRECTLY BELOW
THE TACTILE CHARACTERS; FLUSH LEFT OR CENTERED. WHEN TACTILE IS
MULTILINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OF
TACTILE TEXT. (CBC 11B-703.5)
13. BRAILLE: CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS
REQUIRED IN OTHER PORTIONS OF THESE (CBC) STANDARDS. DOTS SHALL BE 1/10
INCH ON CENTERS IN EACH CELL WITH 2/10 INCH SPACE BETWEEN CELLS,
MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST
COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF
1/40 INCH ABOVE THE BACKGROUND. (CBC 11B-703.3)
1.
ADDRESS NUMBERS MUST BE 12" TALL AND AUTOMATICALLY ILLUMINATED
AND FACING THE STREET. (FRONT AND REAR) UMC 8.28050-505.1A.
2. 2013 CALIFORNIA FIRE CODE CHAPTER 14 - THESE ARE FIRE/ LIFE SAFETY
REGULATIONS THAT THE CONTRACTOR MUST ADHERE TO DURING
CONSTRUCTION.
3. THE INSPECTOR MAY REQUIRE ADDITIONAL EXIT SIGNS AND FIRE
EXTINGUISHERS AT THE TIME OF FINAL INSPECTION.
1.
2.
3.
4. PROVIDE A SIGN ABOVE THE MAIN ENTRANCE DOOR STATING " THIS DOOR
MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. " 2013 CFC CHAP.
10 SEC. 1008.1.9.3.
5. G.C. TO PROVIDE AND INSTALL A 3200 SERIES WITH HINGE DOOR KNOX BOX
FOR EACH BUILDING (BOTH FRONT AND REAR) AND MOUNTED NO HIGHER
THAN 5 FEET FROM FLOOR LEVEL. PROVIDE A MASTER KEY AT FINAL
INSPECTION. 2013 CFC CHAP. 5 SEC. 506.
1.
7. A HIGH PILE STOCK (HPS) REVIEW WAS NOT PART OF THIS APPROVAL.
ANY PROPOSED HPS MUST BE SUBMITTED SEPARATELY.
2.
8. THE SPRINKLER SYSTEM IS REQUIRED TO BE MONITORED BY A UL CENTRAL
STATION FIRE ALARM SYSTEM AND THAT ALL DUCT SMOKE DETECTORS
MUST ALSO BE MONITORED BY THE ALARM. UMC 8.28.090-907.1.6.
10. BOLLARD PROTECTION FOR ALL RISERS IN THE WAREHOUSE IS REQUIRED
UNLESS THEY ARE IN AN ENCLOSURE.
11. FIRE PREVENTION BUREAU MUST INSPECT THE BUILDING FOR FINAL
INSPECTION AND GRANT ACCEPTANCE BEFORE THE BUILDING
DEPARTMENT IS SUMMONED FOR THEIR FINAL INSPECTION. PLEASE CALL
FIRE PREVENTION BUREAU FOR INSPECTIONS.
ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF CONCRETE BLOCK, OR
TO FACE OF STUD, UNLESS NOTED OTHERWISE.
3.
4.
5.
THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THIS PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS. THE CONTRACTOR SHALL PROVIDE PUBLIC
PROTECTION AS NECESSARY AND REQUIRED BY GOVERNING CITY
AGENCIES.
TEMPORARY PEDESTRIAN PROTECTION SHALL BE PROVIDED PER CBC
3303.2 AND AS REQUIRED BY THE LOCAL JURISDICTION.
THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WORK OF
ALL OF OWNER'S SUB-CONTRACTORS AND SHALL PERFORM SUCH
MISCELLANEOUS WORK AS MAY BE NECESSARY FOR THEM TO COMPLETE
THEIR WORK.
THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS ON THE JOB SITE AND REPORT ANY AND ALL DISCREPANCIES
AND/OR UNUSUAL CONDITIONS TO THE ARCHITECT PRIOR TO FINALIZING
BIDS OR COMMENCEMENT OF ANY CONSTRUCTION.
13. THE FOLLOWING SUBMITTAL ARE DEFERRED AND MUST BE SUBMITTED
SEPARATELY:
THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND VERIFY
GOVERNING AUTHORITIES' REQUIREMENTS FOR CONSTRUCTION.
7.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS FOR
INSPECTIONS AND/OR TESTS, UNLESS NOTED OTHERWISE.
8.
UNLESS NOTED OTHERWISE ON THESE DRAWINGS OR IN THE
SPECIFICATIONS AS BEING NOT IN CONTRACT OR EXISTING, ALL ITEMS,
MATERIALS, ETC., AND THE INSTALLATION OF SAME ARE A PART OF THE
CONTRACT DEFINED BY THESE DRAWINGS AND SPECIFICATIONS.
14. ALL EXTERIOR DOORS MUST BE ACCESSIBLE FOR EMERGENCY ACCESS
FOR THE FIRE DEPARTMENT. CFC 203 CHAPTER 5 SECTION 504.1.
CONSTRUCTION NOTES
15. PROVIDE PARAPET ACCESS SIGNAGE PER UPLAND FIRE DEPARTMENT TO
IDENTIFY PARAPET LADDERS.
17. PRIOR TO CERTIFICATE OF OCCUPANCY ALL FIRE AND BUILDING
INSPECTION MUST BE COMPLETED AT FINAL INSPECTION. NO BUILDING
OR STRUCTURE SHALL BE USED OR OCCUPIED UNTIL BUILDING OFFICIAL
AND FIRE INSPECTOR ISSUES A CERTIFICATE OF OCCUPANCY.
1.
DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR
MODIFICATIONS MAY BE REQUIRED TO SUIT THE FIELD DIMENSIONS OR
CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF
THE WORK OF THE CONTRACT AT NO ADDITIONAL COST.
2.
THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING, UNLESS NOTED
OTHERWISE AS REQUIRED FOR NAILING OF ALL INTERIOR AND EXTERIOR
TRIMS, FINISHES, AND SHALL PROVIDE FOR ALL THE NECESSARY FRAMING
AND BRACING FOR THE INSTALLATION OF NOT IN CONTRACT EQUIPMENT
INDICATED.
18. MUST KEEP A COPY OF THE APPROVED FIRE STAMP SET OF PLANS ON THE
JOB SITE AT ALL TIMES.
19. KNOX-LOCKING FIRE DEPARTMENT CONNECTION CAPS: LOCKING CAPS TO
PREVENT FIRE DEPARTMENT CONNECTION (FDC) THEFT ARE REQUIRED
ON ALL FDC FOR WATER-BASED FIRE PROTECTION SYSTEM. CONTACT THE
UPLAND FIRE DEPARTMENT FOR SPECIFICATIONS AND APPLICATION. CFC
2013 CHAP. 9 SEC. 912.3.1.
21. FIRE DEPARTMENT CONNECTION SIGNAGE: A METAL SIGN WITH RAISED
LETTERS AT LEAST 1 INCH IN SIZE (ADDRESS ONLY) SHALL BE MOUNTED
ON ALL FIRE DEPARTMENT CONNECTIONS SERVING AUTOMATIC
SPRINKLER SYSTEM. CFC 2013 CHAP. 9 SEC. 912.4.
22. FDC ACCESS: IMMEDIATE ACCESS TO FIRE DEPARTMENT CONNECTIONS
SHALL BE MAINTAINED AT ALL TIMES AND WITHOUT OBSTRUCTION BY
FENCES, BUSHES, TREES, WALL OR ANY OTHER OBJECTS FOR MINIMUM
OF 3 FEET. CFC 2013 CHAP. 9 SEC. 912.3.2.
14. TRAFFIC-CONTROL DEVICES; POLE-SUPPORTED PEDESTRIAN TRAFFIC-CONTROL
BUTTONS SHALL BE IDENTIFIED WITH COLOR CODING CONSISTING OF A TEXTURED
HORIZONTAL YELLOW BAND 2 INCHES IN WIDTH ENCIRCLING THE POLE, AND A 1
INCH WIDE DARK BORDER BAND ABOVE AND BELOW THIS YELLOW BAND. COLOR
CODING SHOULD BE PLACED IMMEDIATELY ABOVE THE CONTROL BUTTON.
CONTROL BUTTONS SHALL BE LOCATED NO HIGHER THAN 48 INCHES ABOVE THE
SURFACE ADJACENT TO THE POLE. (CBC 11B-703.7.2.7)
15. MEANS OF EGRESS SIGNS AND IDENTIFICATION FOR VISUAL EXIT SIGNS, GRAPHICS,
ILLUMINATION, POWER SOURCE, TACTILE EXIT SIGNAGE, TACTILE STAIR LEVEL
IDENTIFICATION AND SPECIAL EGRESS CONTROL DEVICES SHALL COMPLY WITH
CBC SECTIONS 1003.2.8.1, 1003.2.8.5, 1003.2.9, 1003.2.10, 1003.3.1.10 AND THE
REQUIREMENTS OF CBC CHAPTER 11B.
3.
4.
5.
6.
UNLESS SPECIFICALLY LOCATED, DOORS SHALL BE CENTERED IN WALL
OR LOCATED WITH DOOR JAMB 8" FROM CENTERLINE OF NEAREST WALL
OR 6" FROM THE FACE OF NEAREST OBSTRUCTION.
THE CONTRACTOR SHALL VERIFY LOCATION AND SIZE OF ALL FLOOR,
ROOF, AND WALL OPENINGS WITH ALL APPLICABLE DRAWINGS.
WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER DUCTS,
PIPING CONDUIT, ETC., THE LARGER STUD OR FURRING SHALL EXTEND
THE FULL LENGTH OF THE SURFACE INVOLVED AND SHALL BE INCLUDED
AS PART OF THE WORK OF THE CONTRACT AT NO ADDITIONAL COST.
PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER OR DRYWALL
WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL, EXCEPT
FLOORS.
7.
THE CONTRACTOR SHALL VERIFY INSERTS AND EMBEDDED ITEMS WITH
ALL APPLICABLE DRAWINGS BEFORE POURING CONCRETE.
8.
PRIOR TO REQUESTING A FOUNDATION INSPECTION, THE CONTRACTOR
SHALL HAVE A REGISTERED ENGINEER FIELD VERIFY THE BUILDING PAD
HEIGHT AND SUBMIT A LETTER TO THE CITY ENGINEER, OWNER &
ARCHITECT, CERTIFYING THE BUILDING PAD HEIGHT AS COMPLYING WITH
THE APPROVED GRADING PLAN.
9.
ALL EXTERIOR EXPOSED METAL (TRIMS, RAILINGS, FRAMES, MOULDINGS,
ETC.) SHALL BE PAINTED, UNLESS NOTED OTHERWISE.
10. IN ALL CASES, PROVIDE ISOLATION OF ALUMINUM FROM ADJACENT STEEL
OR COAT SURFACES IN CONTACT WITH BITUMINOUS PAINT.
LAVATORIES
GRAB BARS
ACCESSIBLE LAVATORIES (11B-213.3.4) LAVATORIES REQUIRED TO BE ACCESSIBLE
SHALL COMPLY WITH THIS SUBSECTION. THE REQUIREMENTS OF THIS SUBSECTION
SHALL APPLY TO LAVATORY FIXTURES, VANITIES AND BUILT-IN LAVATORIES.
1. GRAB BARS FOR WATER CLOSETS LOCATED WITHIN A COMPARTMENT SHALL
COMPLY WITH SECTION 11B-604.8.2.3 AND SHALL BE PROVIDED ON THE SIDE WALL
CLOSEST TO THE WATER CLOSET AND ON THE REAR WALL. GRAB BARS FOR WATER
CLOSETS LOCATED WITHIN AMBULATORY COMPARTMENTS SHALL COMPLY WITH
SECTION 11B-604.8.1.5 AND SHALL BE PROVIDED ON BOTH SIDES OF THE
COMPARTMENT. (CBC 11B-604.5)
1.
2.
3.
4.
FAUCET CONTROLS AND OPERATING MECHANISMS FOR SINKS SHALL BE OPERABLE
WITH ONE HAND IN ACCORDANCE WITH THIS CHAPTER AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO
ACTIVATE CONTROLS SHALL BE NOT GREATER THAN 5 POUND-FORCE (LBF).
LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS
(PREFERABLE) ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES
ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. (CBC
11B-606.4)
HOT WATER AND DRAINPIPES ACCESSIBLE UNDER LAVATORIES SHALL BE
INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE
SURFACES UNDER LAVATORIES. (CBC 11B-306)
1.
2.
2. GRAB BARS SHALL NOT PROJECT MORE AN 3 INCHES INTO THE REQUIRED CLEAR
FLOOR SPACE. (CBC 1115B.4.1.3)
A. SIDE WALL: THE SIDE GRAB BAR SHALL BE 42 INCHES LONG MINIMUM,
LOCATED 12 INCHES FROM THE REAR WALL AND EXTEND 54 INCHES
MINIMUM FROM THE REAR WALL WITH THE FRONT END POSITIONED 24
INCHES MINIMUM IN FRONT OF THE WATER CLOSET. THE SIDE GRAB BAR
SHALL BE SECURELY ATTACHED AND CENTERED 33 INCHES ABOVE AND
PARALLEL TO THE FLOOR. (CBC 11B-604.5)
LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE
A MINIMUM OF 18 INCHES TO THE CENTERLINE OF THE FIXTURE. ALL LAVATORIES
THAT ARE DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM 17 INCHES IN
HORIZONTAL DEPTH AND MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHER
THAN 34 INCHES ABOVE THE FINISHED FLOOR AND WITH VERTICAL CLEARANCE
MEASURED FROM THE BOTTOM OF THE APRON OR THE OUTSIDE BOTTOM EDGE OF
THE LAVATORY OF 29 INCHES REDUCING TO 27 INCHES AT A POINT LOCATED 8 INCH
BACK FROM THE FRONT EDGE. IN ADDITION, A MINIMUM OF 9-INCH HIGH TOE
CLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD THE WALL TO A
DISTANCE NO MORE THAN 6 INCHES FROM THE BACK WALL. TOE CLEARANCE
SPACE MUST BE FREE OF EQUIPMENT OR OBSTRUCTIONS. (CBC 11B-606.2, 11B-606.3
& 11B-606.6)
A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES COMPLYING WITH SECTION 1118B.4
SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARD APPROACH.
SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE
AND SHALL EXTEND A MAXIMUM OF 19 INCHES INTO KNEE AND TOE SPACE
UNDERNEATH THE LAVATORY. KNEE CLEARANCE) (CBC 11B-606.2)
ELECTRICAL
B. REAR WALL: THE REAR GRAB BAR SHALL BE 36 INCHES LONG MINIMUM
AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES
MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE.
THE REAR GRAB BAR SHALL BE SECURELY ATTACHED AND PARALLEL TO
THE FLOOR, EXCEPT WHERE A TANK-TYPE TOILET IS USED WHICH
OBSTRUCTS PLACEMENT AT 33 INCHES, THE GRAB BAR MAY BE AS HIGH
AS 36 INCHES AND THE SPACE BETWEEN THE GRAB BAR AND THE TOP
OF THE TANK SHALL BE 1-1/2 INCHES MINIMUM. (CBC 11B-604.5)
3.
12. ADDITIVES OR ADMIXTURES, IF USED, REQUIRE PRIOR APPROVAL FROM
THE BUILDING OFFICIAL.
THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF CONTROLS OR
SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO
CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING,
HEATING, AND VENTILATING EQUIPMENT SHALL MEET THE REQUIREMENTS OF CBC
SECTION 11B, SPACE ALLOWANCE AND REACH RANGES, FOR PERSONS WITH
DISABILITIES AND SHALL NOT BE MORE THAN 48 INCHES ABOVE THE FLOOR OR
WORKING PLATFORM.
13. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND
UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION
FACILITIES (POWER POLES, PULL-BOXES, TRANFORMERS, VAULTS, PUMPS,
VALUES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE
HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE
PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS
AND/OR ADDITIONAL EXPENSES.
(REFER TO ADA DETAIL SHEETS)
3.
(CBC 11B-604.4)
3. CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING. CONTROLS FOR THE FLUSH VALVES SHALL BE
FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER
THAN 5 POUNDS-FORCE (LBF). (CBC 11B-604.6)
14. PROVIDE ANTI-GRAFFITI FINISH AT THE FIRST 9 FEET, MEASURED FROM
GRADE, AT EXTERIOR WALLS AND DOORS.
15. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS SHALL BE
TESTED AS SPECIFIED IN SECTION 803.1.1 OF THE CBC.
SINGLE ACCOMMODATION SANITARY FACILITIES
NOTE:
SINGLE ACCOMMODATION SANITARY FACILITY IS DEFINED AS "A ROOM
THAT HAS NOT MORE THAN ONE OF EACH TYPE OF SANITARY FIXTURE, IS INTENDED
FOR USE BY ONLY ONE PERSON AT A TIME, HAS NO PARTITION AROUND THE TOILET,
AND HAS A DOOR THAT CAN BE LOCKED ON THE INSIDE BY THE ROOM OCCUPANT".
(CBC 202)
ACCESSIBLE URINALS: URINALS REQUIRED TO ACCESSIBLE SHALL COMPLY WITH THIS
SUBSECTION: (CBC 11B-213.3.3)
1. URINALS SHALL BE FLOOR MOUNTED, STALL-TYPE OR WALL HUNG. WHERE ONE OR
MORE WALL-HUNG URINALS ARE PROVIDED, AT LEAST ONE WITH AN ELONGATED
RIM PROJECTING A MINIMUM OF 14" FROM THE WALL AND A MAXIMUM OF 17" FROM
THE WALL AND A MAXIMUM OF 17" ABOVE THE FLOOR SHALL BE PROVIDED. (CBC
11B-605.2)
2. FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST AND SHALL BE MOUNTED
NO MORE THAN 44" ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE
CONTROLS SHALL BE NO GREATER THAN 5LBF. ELECTRONIC AUTOMATIC FLUSHING
CONTROLS ARE ACCEPTABLE AND PREFERABLE. (CBC 11B-605.4)
3. WHERE URINALS ARE PROVIDE, AT LEAST ON SHALL HAVE A CLEAR FLOOR SPACE
30" BY 48" IN FRONT OF THE URINAL TO ALLOW FORWARD APPROACH. THE CLEAR
SPACE SHALL COMPLY WITH SECTION 11B-605.3
THE CONTRACTOR SHALL FURNISH AND INSTALL FIRE EXTINGUISHERS AS
APPROVED AND REQUIRED BY THE FIRE MARSHALL. LOCATIONS SHALL BE
DETERMINED IN THE FIELD BY THE FIRE MARSHALL.
3.
4.
THE BUILDING SHALL BE COMPLETELY SPRINKLERED WITH AN AUTOMATIC
FIRE EXTINGUISHING SYSTEM AS APPROVED BY THE GOVERNING FIRE AND
BUILDING DEPARTMENTS AND THE OWNER'S FIRE INSURANCE RATING
BUREAU. COPIES OF FIRE DEPARTMENT AND INSURANCE BUREAU
APPROVED PLANS SHALL BE SUBMITTED AND APPROVED BY THE FIRE
PREVENTION BUREAU UNDER A SEPARATE PERMIT. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF A
COMPLETE SYSTEM, FROM CONNECTION TO THE SITE WATER MAIN (OR
SITE FIRE SERVICE VAULT WHERE PROVIDED) TO THE BUILDING INTERIOR
SPRINKLER DISTRIBUTION. REFER TO SPECS AND PLANS. ALL SPRINKLER
LINES SHALL RUN CONCEALED IN ALL FINISHED AREAS. INTERFERENCE
WITH LIGHTS, DUCTS, PIPES, ETC. SHALL BE AVOIDED. EXPOSED PIPING IN
FINISHED AREAS IS UNACCEPTABLE. AUTOMATIC FIRE EXTINGUISHING
SYSTEM MUST BE FULLY OPERATIONAL AND ENERGIZED PRIOR TO
FIXTURIZATION OF THE BUILDING. SPRINKLER HEADS WILL NOT BE
ALLOWED WITHIN THE OPENING AREA OF SKYLIGHTS OR ROOF ACCESS
UNLESS SPECIFICALLY REQUIRED BY THE GOVERNING FIRE OR BUILDING
DEPARTMENTS.
PROVIDE A MINIMUM, UNOBSTRUCTED WIDTH OF 26" CLEAR TO THE SKY,
VEHICULAR ACCESS TO WITHIN 150 FEET OF ALL PORTIONS OF THE
EXTERIOR WALLS.
5.
VEHICULAR ACCESS MUST BE PROVIDED AND MAINTAINED SERVICEABLE
THROUGHOUT CONSTRUCTION.
6.
THE REQUIRED FIRE FLOW FOR PUBLIC FIRE HYDRANTS AT THIS LOCATION
IS XXXX GALLONS PER MINUTE AT 20 PSI FOR A DURATION OF 2 HOURS
OVER AND ABOVE MAXIMUM DAILY DOMESTIC DEMAND. [NOTE TO
DESIGNER: VERIFIED NUMBERS WITH LOCAL FIRE DEPARTMENT. THEN
DELETE THIS REMINDER.]
(NOT USED)
7.
ALL HYDRANTS SHALL BE BRASS OR BRONZE AND MEASURE 6"x4"x2",
CONFORMING TO CURRENT AWWA STANDARD C503, OR APPROVED
EQUAL. HYDRANTS SHALL BE INSTALLED PER SPECIFICATIONS OF THE
GOVERNING AGENCY. (NOT USED)
8.
BUILDING ADDRESS NUMBERS TO BE PROVIDED ON THE FRONT OF ALL
BUILDINGS AND SHALL BE VISIBLE AND LEGIBLE FROM STREET FRONTING
THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR
BACKGROUND.
9.
DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE
SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H
OCCUPANCY.
10. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR
THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF
NOT LESS THAN 32 INCHES. CLEAR OPENINGS OF DOORWAYS WITH
SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE
DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. WHERE THIS
SECTION REQUIRES A MINIMUM CLEAR WIDTH OF 32 INHCHES AND A
DOOR OPENING INCLUDES TWO DOOR LEAVES WITHOUT A MULLION, ONE
LEAF SHALL PROVIDE A CLEAR OPENING WIDTH OF 32 INCHES. THE
MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48 INCHES
NOMIAL. MEANS OF EGRESS DOORS IN A GROUP 1-2 OCCUPANCY USED
FOR THE MOVEMENT OF BEDS AND LITTER PATIENTS SHALL PROVIDE A
CLEAR WIDTH NOT LESS OF 44 INCHES. THE HEIGHT OF DOORS SHALL
NOT BE LESS THAN 80 INCHES.
11. EXCEPT AS SPECIALLY PERMITTED BY THIS SECTION EGRESS DOORS
SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT USE OF
A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
16. THE CLIENT, ARCHITECT, CONSULTANTS, AND ALL INSPECTORS FROM
PERTINENT AGENCIES SHALL BE PERMITTED ACCESS TO THE JOB SITE AT
ALL TIMES DURING NORMAL WORKING HOURS.
17. IT IS CRITICAL THAT THE GEOTECHNICAL ASPECTS OF THE PROJECT BE
REVIEWED BY THE GEOTECHNICAL CONSULTANT DURING THE
CONSTRUCTION PROCESS. COMPLIANCE WITH THE DESIGN CONCEPTS,
SPECIFICATIONS OR RECOMMENDATIONS DURING CONSTRUCTION
REQUIRES REVIEW BY THE GEOTECH DURING THE COURSE OF
CONSTRUCTION. ALL FOUNDATIONS SHOULD BE OBSERVED BY A
REPRESENTATIVE OF THE GEOTECHNICAL CONSULTANT PRIOR TO
PLACING CONCRETE OR STEEL REBAR. ANY FILL WHICH IS PLACED
SHOULD BE OBSERVED, TESTED, AND VERIFIED IF USED FOR ENGINEERED
PURPOSES. ADVISE THE GEOTECH AT LEAST TWENTY-FOUR HOURS PRIOR
TO ANY REQUIRED SITE VISIT.
1.
GLAZING NOTES PER CBC CHAPTER 24:
A.
ALL FIXED AND OPENABLE WINDOWS FROM ZERO TO 50 SQUARE FEET IN
AREA SHALL HAVE 3/8" MINIMUM GLASS GRIP AND 1/4" MINIMUM GLASS
EDGE CLEARANCE.
B.
ALL FIXED AND OPENABLE WINDOWS OVER 50 SQUARE FEET IN AREA
SHALL HAVE 1/2" MINIMUM GLASS GRIP AND 1/4" MINIMUM GLASS EDGE
CLEARANCE.
C.
GLAZING IN ALUMINUM DOORS SHALL HAVE 5/16" MINIMUM GLASS GRIP
AND 3/16" MINIMUM GLASS EDGE CLEARANCE.
D.
ALL WINDOW AND DOOR GLAZING SHALL HAVE CONTINUOUS GLAZING
RABBET AND GLASS RETAINER AND RESILIENT SETTING MATERIAL.
2.
GLASS DOORS, ADJACENT PANELS, AND ALL GLAZED OPENINGS WITHIN 18
INCHES MIN. OF ADJACENT FLOOR SHALL BE OF GLASS APPROVED FOR
IMPACT HAZARD.
3.
EACH LIGHT OF SAFETY GLAZING MATERIAL INSTALLED IN HAZARDOUS
LOCATIONS SHALL BE IDENTIFIED BY A PERMANENT LABEL THAT
SPECIFIES THE LABELER, AND STATES THE SAFETY GLAZING MATERIALS
HAS BEEN UTILIZED IN SUCH INSTALLATIONS. THE FOLLOWING SHALL BE
CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF
GLAZING:
A.
GLAZING IN INGRESS AND EGRESS DOORS EXCEPT JALOUSIES.
B.
GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE
THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 20 INCH
ARC OF VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND
WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN
60 INCHES ABOVE THE WALKING SURFACE.
C.
GLAZING IN AN INDIVIDUAL FIXED OF OPERABLE PANEL THAT MEET ALL OF
THE FOLLOWING CONDITIONS:
1.
EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET.
2.
EXPOSED BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
3.
EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
4.
ONE OF MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF
THE PLANE OF THE GLAZING.
13. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED,
WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN FIVE FOOT-CANDLE
AT FLOOR LEVEL. CBC SECTION 1011.5.2.
1.
EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN
THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE,
IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES FROM
EITHER OF TWO ELECTRIC LAMPS. INTERNALLY ILLUMINATED SIGNS SHALL
PROVIDE EQUIVALENT LUMINANCE AND BE LISTED FOR THE PURPOSE.
2013 CBC SECTION 1011.2.
2.
THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY
ELECTRICAL SYSTEM WHICH IS TO PROVIDE CONTINUED ILLUMINATION
FOR A DURATION OF NOT LESS THAN 1-1/2 HOURS IN CASE OF PRIMARY
POWER LOSS. CONTINUED ILLUMINATION IS TO BE PROVIDED FROM
STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON SITE GENERATOR SET,
AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE
ELECTRICAL CODE AND CBC SECTION 1011.5.3.
3.
THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE
PROVIDED BY THE PREMISE'S ELECTRICAL SUPPLY. IN THE EVENT OF ITS
FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN
EMERGENCY SYSTEM FOR THE FOLLOWING:
4.
PROVIDE EXIT SIGNS AT ALL LEGAL EXITS. EXIT SIGNS SHALL BE
ILLUMINATED AND READ "EXIT" IN 6 INCH HIGH LETTERS AND SHALL BE ON
A SEPARATE CIRCUIT AND INDEPENDENTLY CONTROLLED. REFER TO
ELECTRICAL DRAWINGS. CBC SECTION 1011.4.
5.
ANY TIME A BUILDING OR PORTION OF A BUILDING IS OCCUPIED, THE
MEANS OF EGRESS SERVING THE OCUPIED PORTION SHALL BE
ILLUMINATED AT A INTENSITY OF NOT LESS THEN 1 FOOT-CANDLE AT THE
FLOOR LEVEL. CBC SECTION 1011.5.2.
6.
WHERE TWO OR MORE EXITS OR EXIT-ACCESS DOORWAYS ARE REQUIRED
AT LEAST TWO MUST HAVE A MINIMUM SEPARATION OF ONE HALF THE
OVERALL MAXIMUM DIAGONAL OF THE BUILDING OR AREA SERVED
MEASURED IN A STRAIGHT LINE BETWEEN THE CENTER OF THE EXITS OR
EXIT-ACCESS.
14. FIELD INSPECTOR SHALL DETERMINE FIRE EXTINGUISHER REQUIREMENTS.
AS INDICATED IN TABLE 906.1.
15. FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH CBC SECTION
717 IN THE FOLLOWING LOCATIONS:
A.
IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS.
B.
IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS INCLUDING
FURRED SPACES, AT 10 FOOT INTERVALS ALONG THE LENGTH OF THE
WALL BOTH HORIZONTALLY AND VERTICALLY.
C.
AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS
COVERED CEILINGS, ETC.
D.
IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND
BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH
THE RUN OF STAIRS IF THE WALL UNDER THE STAIRS IS UNFINISHED.
Seal:
A Project for:
EXITING NOTES
12. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED PER CBC
SECTION 1011.2.
7.
16. IN FIRE-RESISTIVE EXTERIOR WALL CONSTRUCTION, THE FIRE-RESISTIVE
RATING RATING MUST BE MAINTAINED FOR SUCH WALLS PASSING
THROUGH ATTIC AREAS.
ALL ENTRANCES AND EXTERIOR GROUND FLOOR EXIT DOORS TO THE
BUILDING AND ITS FACILITIES SHALL BE ACCESSIBLE AND FUNCTIONAL TO
PERSONS WITH DISABILITIES.
Client:
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
CLEAR FLOOR OR GROUND SPACE
11. ALL EXTERIOR WALL OPENINGS, FLASHINGS, COPINGS AND EXPANSION
JOINTS SHALL BE WEATHERPROOF.
THE CENTER OF JUNCTION BOX FOR ELECTRICAL AND COMMUNICATION SYSTEM
RECEPTACLE OUTLETS SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION
MEETING THE CLEARANCES AND REACH RANGE REQUIREMENTS OF CBC SECTION
11B AND NOT LESS THAN 15 INCHES ABOVE THE FLOOR OR WORKING PLATFORMS.
HEIGHT: THE HEIGHT OF THE MANUAL FIRE ALARM BOXES SHALL HAVE A MINIMUM
OF 48 INCHES MEASURED VERTICALLY, FROM THE FLOOR LEVEL TO THE HEIGHTS
POINT OF THE ACTIVATING HANDLE OR LEVER OF THE BOX. (CBC 907.3.2)
2.
THE WORK SHALL COMFORM TO THE APPLICABLE BUILDING CODE,
ORDINANCES, CODES, AND REGULATIONS LISTED IN THE SPECIFICATIONS,
OR ON THE DRAWINGS, AND AS REQUIRED BY LOCAL BUILDING
AUTHORITIES. THE GOVERNING CODES, RULES AND REGULATIONS ARE
COLLECTIVELY REFERRED TO AS "THE CODE". THE CONTRACTOR SHALL
REPORT ANY INCONSISTENCIES, CONFLICTS, OR OMISSIONS HE MAY
DISCOVER TO THE ARCHITECT FOR INTERPRETATION PRIOR TO
PERFORMING THE WORK.
6.
16. LABEL ALL "FIRE ALARM CONTROL PANELS" AND "ELECTRICAL ROOM" WITH
6" LETTERS, CFC 2013 CHAPTER 5 SECTION 509.1
ALL REQUIRED PERMITS MUST BE OBTAINED FROM THE FIRE DEPARTMENT
PRIOR TO START OF CONSTRUCTION.
ALL INTERIOR WALL DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED
OTHERWISE.
12. FIRE SPRINKLER AND/OR FIRE ALARM MODIFICATIONS HAVE NOT BEEN
REVIEWED AS A PART OF THIS SUBMITTAL AND SEPARATE SUBMITTALS
ARE REQUIRED.
A. FIRE SPRINKLER SYSTEM
B. FIRE ALARM SYSTEM
C. CONSTRUCTION TRAILER (PROVIDE SITE PLAN AND LOCATION)
1.
CONTRACTORS NOTES
6. PROVIDE FIRE EXTINGUISHERS IN THE OFFICE AT THE RATIO OF 1 PER 3,000
SQ. FT. WITH A MAXIMUM TRAVEL DISTANCE OF 75 FEET. THE MINIMUM
FIRE EXTINGUISHER TYPE REQUIRED IS "2A10BC".
9. ACCESS TO EQUIPMENT SUCH AS AUTOMATIC FIRE SPRINKLER AND FIRE
ALARM SHALL BE LOCATED IN AN ATTACHED OR INCLUDED ROOM OR AN
APPROVAL WEATHER RESISTANT ENCLOSURE WITH AT LEAST ONE
EXTERIOR ACCESS DOOR OF NOT LESS THAN 3'-0" X 6'-8". UMC
8.28.050-510.2.
DO NOT SCALE THESE DRAWINGS. SHOULD ANY DIMENSIONAL
DISCREPANCIES BE ENCOUNTERED, CLARIFICATIONS SHALL BE OBTAINED
FROM THE ARCHITECT.
GLAZING NOTES
FIRE NOTES
1.
MECHANICAL, PLUMBING, & ELECTRICAL NOTES
1.
2.
3.
PROVIDE VENTILATION FOR ALL ELECTRICAL AND TELEPHONE EQUIPMENT
ROOMS.
MECHANICAL VENTILATION SHALL SUPPLY A MINIMUM 5 CFM OF OUTSIDE
AIR, EXCEPT IN TOILET ROOMS WHERE FIVE (5) AIR CHANGES PER HOUR
SHALL BE PROVIDED. SYSTEM MUST PROVIDE A TOTAL CIRCULATION OF
NOT LESS THAN 15 CUBIC FEET PER MINUTE PER OCCUPANT IN ALL
PORTIONS OF THE BUILDING. REFER TO MECHANICAL DRAWINGS. 2010
CALIFORNIA MECHANICAL CODE.
KEEP PIPING AS CLOSE TO WALLS AND AS HIGH TO UNDERSIDE OF ROOF
FRAMING AS POSSIBLE.
4.
PROVIDE ATTIC VENTILATION PER CBC SECTION 1203.2.
5.
AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE
FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND
BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OF
STRUCTURE CONTAINING THE FUEL GAS PIPING. SEPARATE PLUMBING
PERMIT IS REQUIRED.
6.
1.
2.
3.
2.
WIDTH FOR WHEELCHAIR PASSING: THE MINIMUM WIDTH FOR TWO WHEELCHAIRS
3.
WHEELCHAIR TURNING SPACE: THE SPACE REQUIRED FOR A WHEELCHAIR TO MAKE
A 180-DEGREE TURN IS A CLEAR SPACE OF 60 INCHES DIAMETER OR A T-SHAPED
SPACE (CBC 11B-304.3)
4.
SIZE AND APPROACH: THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED
TO ACCOMMODATE A SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30
INCHES BY 48 INCHES. THE MINIMUM CLEAR FLOOR OR GROUND SPACE FOR
WHEELCHAIRS MAY BE POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN
OBJECT. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE A PART OF
THE KNEE SPACE REQUIRED UNDER SOME OBJECTS. (CBC 11B-305.3, 11B-305.4 &
11B-305.5)
5.
RELATIONSHIP OF MANEUVERING CLEARANCES TO WHEELCHAIR: ONE FULL
UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE FOR A
WHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOIN
ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. IF A CLEAR FLOOR SPACE IS
LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE
SIDES, ADDITIONAL MANEUVERING CLEARANCES SHALL BE PROVIDED AS SHOWN IN
CBC FIGURE 11B5-5A(b). (CBC 11B-305.6, 11B-305.7)
6.
FORWARD REACH: IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD
APPROACH TO AN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL
BE 48 INCHES (SEE CBC FIGURE 11B-C(b)). THE MINIMUM LOW FORWARD REACH IS
15 INCHES. IF THE HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH AND
CLEARANCES SHALL BE AS SHOWN IN CBC FIGURE 11B-5C(a). (CBC 11B-308.2)
PLUMBING FIXTURES SHALL BE PROVIDED IN ACCORDANCE WITH THE 2013
CALIFORNIA PLUMBING CODE.
TITLE 24 ENERGY NOTES
MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS SHALL EACH
PROVIDE TO THE BUILDING OFFICIAL PRIOR TO FINAL INSPECTION, A
COMPLETED TITLE 24 ENERGY COMPLIANCE FORM IC-2 (INSTALLATION
CERTIFICATE FOR MANUFACTURED DEVICES) WHICH IS SIGNED BY THE
INSTALLER AND GENERAL CONTRACTOR FOR MANUFACTURED DEVICES
GOVERNED BY TITLE 24, BUILDING ENERGY EFFICIENT STANDARDS.
INSULATION CONTRACTOR(S) SHALL PROVIDE TO THE BUILDING OFFICIAL
PRIOR TO FINAL INSPECTION, A COMPLETED TITLE 24 ENERGY
COMPLIANCE FORM IC-1 (INSULATION CERTIFICATE) SIGNED BY THE
INSTALLER(S) AND GENERAL CONTRACTOR FOR INSULATING MATERIAL OF
ENVELOPE GOVERNED BY TITLE 24, BUILDING ENERGY EFFICIENCY
STANDARDS.
WHEELCHAIR PASSAGE WIDTH: THE MINIMUM CLEAR WIDTH FOR SINGLE
WHEELCHAIR PASSAGE SHALL BE 32 INCHES AT A POINT AND 36 INCHES
CONTINUOUSLY. (CBC 11B-403.5.1)
7.
8.
SIDE REACH: IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A
PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED SHALL BE 54
INCHES AND THE LOW SIDE REACH SHALL BE NO LESS THAN 9 INCHES ABOVE THE
FLOOR. IF THE SIDE REACH IS OVER AND OBSTRUCTION, THE REACH AND
CLEARANCES SHALL BE AS SHOWN IN
(CBC 11B-308.3)
2580 BELL ROAD
AUBURN, CA 95603
1.
DIMENSIONING NOTES
FIRE DEPARTMENT NOTES
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
SANITARY FACILITY FIXTURES & ACCESSORIES
TENANT IMPROVEMENT
SIGNS & IDENTIFICATION
Revisions:
No.
Description
Project No.:
Drawn By:
Reviewed By:
Scale:
Date:
Filename:
Date
15.083.10
JA
RN
AS NOTED
03-11-15
--
Sheet Title:
GENERAL &
ACCESSIBLE
NOTES
(FOR REFERENCE ONLY)
Sheet #:
ALL WATER CLOSETS ARE TO BE OF THE LOW WATER CONSUMPTION
TYPE.
G-103
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
*
TOILET FIXTURES (TF)
TA
17
SUFRFACE MOUNTED TOILET TISSUE DISPENSER (-)
TF
1
STANDARD CEILING HUNG TOILET PARTITION (10160.A)
TA
2
RECESSED TOILET SEAT COVER DISPENSER
& ROLL TOILET TISSUE DISPENSER (B 3474)
PARTITION MOUNTED T/2 FOR HC (B 3471)
(ONE SIDE FLUSH)
TA
5A
TA
18
BABY DIAPER CHANGING STATION (-)
TF
1A
HEAVY DUTY CEILING HUNG TOILET PARTITION (10160.B)
TA
19
ELECTRIC HAND DRYER (-)
TF
2
WALL HUNG URINAL DIVIDER (10160.C) MAX DEPTH 24"
TA
2B
T/2 MOUNTED ON TOILET PARTITION (B 347)
TA
6A
SURFACE MOUNTED PAPER TOWEL DISPENSER &
(12 GAL) WASTE RECEPTACLE (B 3944 W/SKIRT)
RECESSED COMBINATION SANITARY NAPKIN &
TAMPON VENDOR (315867 x 25 CENTERLINE)
SURFACE MOUNTED T/6 ABOVE
(316988 x 25 CENTERLINE)
TA
20
NOT USED
TF
3
WALL HUNG WATER CLOSET
TA
2C
T/2 SURFACE MOUNTED ABOVE (B 3479)
TA
7
RECESSED SOAP DISPENSER (B 306)
TA
21
NOT USED
TF
3S
WALL HUNG WATER CLOSET, STAINLESS STEEL
TA
3
RECESSED TOILET SEAT COVER DISPENSER, NAPKIN
DISPOSAL & TOILET TISSUE DISPENSER (B 3574)
PARTITION MOUNTED (ONE SIDE FLUSH) T/3
FOR USE IN H/C COMPARTMENT (B 3571)
TA
7A
SURFACE MOUNTED T/7 ABOVE (B 4112)
TA
22
NOT USED
TF
4
WALL HUNG URINAL
TA
8
GRAB BAR MOUNTING
TF
4S
WALL HUNG URINAL, STAINLESS STEEL
T/3 MOUNTED ON TOILET PARTITION (B 357)
TA
9
TOILET GRAB BAR (36" x 54") (B 5837)
TF
5
WALL HUNG LAVATORY
TA
3C
SURFACE MOUNTED T/3 (B 3579)
TA
10
MIRROR WITH 5" DEEP SHELF (B 292)
WALL HUNG LAVATORY, STAINLESS STEEL
TA
3D
SURFACE MOUNTED MULTI-ROLL
TOILET TISSUE DISPENSER (B 288)
RECESSED PAPER TOWEL DISPENSER &
(12 GAL) WASTE RECEPTACLE (B 3944)
NOT USED
TF
6
TA
11
SURFACE MOUNTED CONDOM VENDOR (B 2801)
COUNTER TOP LAVATORY
SURFACE MOUNTED TOILET
SEAT COVER DISPENSER (B 221)
NOT USED
TF
7
TA
12
TM
2
NOT USED
TF
8
WALL HUNG LAVATORY W/STAINLESS STEEL SHELF
& BENT STEEL BARRIER CURB ATTACHED TO FLOOR
TA
4A
RECESSED WASTE RECEPTACLE (12 GAL) (B 3644)
TA
13
TM
3
SANITARY NAPKIN DISPOSAL (B 254)
TF
9
NOT USED
TA
4B
FULLY OR PARTIALLY RECESSED PAPER TOWEL
DISPENSER & (12 GAL) WASTE RECEPTACLE (B 3900)
TA
14
SURFACE MOUNTED PAPER TOWEL DISPENSER (B 4262)
TF
10
NOT USED
TA
4C
FULLY RECESSED WASTE RECEPTACLE (B 367)
TA
15
SURFACE MTD (20 GAL) WASTE RECEPTACLE (B 275)
TF
11
NOT USED
TA
4D
FULLY RECESSED PAPER TOWEL DISPENSER
& WASTE RECEPTACLE (B 3803)
TA
16
RECESSED TOILET TISSUE DISPENSER (-)
SINGLE OCCUPANCY TOILET
TA
9
TA
8
TF
4S
TF
4
TF
2
TF
2
TF
7
TA
1
TF
8
TF
6
TF
7
TA
7A
TA
7
TA
1
TA
10
TA
4D
TA
4C
TA
4B
TA TA
4A 5A
TA TA
4
5
TF
6
TF
5
TA
11
TA
6A
TA
6
17" MIN
19" MAX
24" STD
17" MAX H/C
30" MIN
H/C
24"
MIN
ACCESSIBLE TOILET STALL
TA
14
TA
15
TA
19
TA
18
TA
12
TF
1A
TF
1
TA
13
40" MAX
TOP OF
CONTROLS
(TYPICAL)
SIGN
1'-0"
1'-0"
RAISED CHARACTERS
FIGURE (A)
6"
18"
6" MAX
EQ
Z
WOMEN
MOUNTING @ DOOR & WALL
B
REQUIREMENTS - TYPICAL
SCALE
NTS
26
36" MIN
B
E
8
SIGNS & PICTOGRAMS
SCALE
3/4" = 1' - 0"
3
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
LEVEL MANUEVERING DISTANCE
No.
RAMP LANDING & DOORWAY
Description
Project No.:
LEVEL MANUEVERING DISTANCE
Drawn By:
AT DOORS HINGE APPROACH (CBC FIG. 11B-404.2.4.1)
48" MINIMUM
PULL SIDE
B
FORWARD REACH
32" CLEAR
(CBC FIG. 11B-308.2.1, 11B-308.2.2 (a) (b)
10"
MAX
2. ROOM SIGN: RAISED & BRAILLED CHARACTERS & PICTORIAL SYMBOL SIGNS
(PICTOGRAMS). LETTERS & NUMERALS SHALL BE RAISED 1/32", UPPERCASE, SANS SERIF
OR SIMPLE SERIF TYPE, & SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED
CHARACTERS SHALL BE 5/8" HIGH MIN, 2" HIGH MAX.
3. FINISH CONTRAST: THE CHARACTERS & BACKGROUND OF SIGNS SHALL BE EGGSHELL,
MATTE, OR OTHER NON-GLARE FINISH.
4. CHARACTERS & SIGNS: SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE
OF THE DOOR.
21
30"
30"
48"
1. DOOR SIGN: SHALL BE CENTERED ON DOOR & MOUNTED 60" ABOVE THE FLOOR
(W/ADHESIVE ONLY - CAULK EDGES W/CLEAR SILICONE) @ THE CENTER OF THE SIGN.
1/4" = 1' - 0"
1/4" = 1' - 0"
ADA SIGNAGE
Reviewed By:
NOTES:
SIGNAGE MOUNTING HEIGHTS
OBJECTS (CBC FIG. 11B-307, 11B-307.3)
SCALE
INTERNATIONAL
SYMBOL OF
ACCESS FOR
HEARING
EMPAIRED
PUSH SIDE
48" MIN
24"
MAX
SCALE
60" MIN
54" MIN
MOUNTING @ WALL (NO DOOR)
ADA SANITARY FACILITIES
FRONT APPROACH (CBC FIG.11B-404.2.4.1)
NOTES:
1. X SHALL BE 25
INCHES; Z SHALL BE X
2. WHEN X < 20 INCHES,
THEN Y SHALL BE 48
INCHES MAXIMUM
3. WHEN X IS 20 TO 25
INCHES, THEN Y SHALL BE
44 INCHES MAXIMUM
PROTRUDING/OVERHANGING
12" MAX
INTERNATIONAL
TDD
SYMBOL
24" MIN EXTERIOR & 18" MIN
INTERIOR BEYOND STRIKE
EDGE OF A GATE OR DOOR
ON THE SIDE TOWARD
WHICH IT SWINGS
LEVEL MANUEVERING DISTANCE
PULL SIDE
Z
48"
DT-ADA-BR-WTR-HI LO-Typical.dwg
ADA WATER FOUNTAIN
PUSH SIDE
48" MINIMUM
54" PREFERRED
* 48" MIN IF DOOR HAS BOTH
A LATCH & A CLOSER
46"
B. INSTALL WING WALLS ON EACH SIDE OF THE DRINKING FOUNTAIN TO PROJECT OUT
FROM THE MAIN WALL AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6"
OF THE PATH OF TRAVEL FLOOR FINISH. THERE MUST BE 32" CLEAR BETWEEN THE
WING WALLS, OR
C. GUARDRAILS SHALL BE A MINIMUM OF 32" CLEAR BETWEEN AND PROJECT FROM THE
SUPPORT WALL TO THE PROJECTING FACE OF THE FOUNTAIN AND WITHIN 6" OF THE
FINISH SURFACE OF THE PATH OF TRAVEL.
2. FOUNTAIN & GUARDRAILS, ETC. SHALL NOT REDUCE THE REQUIRED ACCESSIBLE ROUTE
AND/OR PATH WIDTH.
A
WALL SIGN
WHERE
OCCURS
48" MIN.
CENTER OF SIGN
1. WARNING FOR THE VISION IMPAIRED AT A PROJECTED DRINKING FOUNTAIN CAN BE
PROVIDED BY EITHER OF THE FOLLOWING MEANS:
A. THE SURFACE OF THE FLOOR OR GROUND AT THE DRINKING FOUNTAIN CAN BE OF
CONTRASTING COLOR WITH A TEXTURE THAT CONTRASTS IN RESILIENCY WITH THE
ADJACENT FINISHED FLOOR MATERIAL, SO THAT IT CAN BE SENSED BY A CANE, WITH
THE TEXTURE EXTENDING FROM THE WALL TO ONE FOOT BEYOND THE FRONT EDGE OF
THE DRINKING FOUNTAIN AND ONE FOOT BEYOND EACH SIDE OF THE FOUNTAIN, OR
X
X
OPEN
5'-0" TO
CENTER OF SIGN
48" MIN.
CENTER OF SIGN
PROJECTED FOUNTAINS
22
1/8" = 1' - 0"
48" MIN
18"
WOMEN
PROJECTED FOUNTAINS
30" MIN
15" MIN
TYPICAL
ROOM ID SIGN
TEXTURED AREA TYPICAL
B
TYPICAL DOOR
SIGN WHERE
OCCURS
SCALE
12" MIN IF DOOR
HAS BOTH A
CLOSER AND A
LATCH
FORWARD REACH LIMIT
48" MAX
27" MIN
APPROACH REQUIRMENTS
EQ
a
32" MIN
CLEAR
NOTES:
1. CLEAR SPACES MUST BE LEVEL TO
PREVENT WHEELCHAIRS FROM
ROLLING WHEN THE OCCUPANT
RELEASES THE WHEEL GRIPS TO
REACH FOR THE DOOR. 1/4" PER
FOOT IS ALLOWED FOR DRAINAGE.
2. WHERE DOORS OPEN ONTO, BUT
NOT INTO A CORRIDOR, THE
REQUIRED LEVEL AREA BEYOND
THE DOORS MAY BE A MINIMUM OF
48". FOR ADDITIONAL INFORMATION,
REFER TO APPLICABLE NOTES ON
TYPICAL ACCESSIBILITY NOTES
SHEET.
(CBC FIG. 11B-304.3.2)
48"
FRONT APPROACHES
ADA DOOR REQUIRMENTS
WIDTH OF DOUBLE UNIT +6" EA
SIDE CLR FOR DOUBLE UNITS
48" MIN
b
24" MIN CLR AT
EXTERIOR DOORS
18" MIN CLE AT
INTERIOR DOORS
REQUIRED CLEAR SPACE
A
60 INCHES DIAMETER SPACE
(CBC FIG. 11B-304.3.1)
Y
RAIL AS OCCURS TYPICAL
(REFER TO FLOOR PLAN)
a
NOTE:
ALL DOOR IN ALCOVES
SHALL COMPLY WITH
CLEARANCES FOR
FRONT APPROACHES.
5'-0" TO
CENTER OF SIGN
A
60" MINIMUM
12" 36" MIN 12"
MIN
MIN
FIGURE (D)
CANE
RANGE
BRAILLE:
15. USE CONTRASTED GRADE 2 BRAILLE DOTS TO BE
.01 INCH ON CENTER IN EACH CELL.
16. .02 INCH SPACE BETWEEN CELLS.
17. DOTS RAISED MIN .0025 INCH ABOVE
BACKGROUND.
Client:
MIN CLR WIDTH FOR TWO WHEELCHAIRS
2
MIN CLR WIDTH FOR ONE WHEELCHAIR
(CBC FIG. 11B-403.5.1)
3'-9"
LATCH SIDE APPROACHES
48" MIN
EXTENT OF WING WALLS
WHERE OCCURS
13
60" MIN
1
X (12" MIN)
60" MIN
A
RECESSED FOUNTAINS
9"
6" MIN
36" MIN
NOTE:
X=12" IF DOOR HAS BOTH A CLOSER & LATCH
24" PREF
18" MIN
SCALE
PULL SIDE
REQUIRED CLEAR SPACE
*44" MIN
C
FIGURE (C)
60" MIN
HINGE SIDE APPROACHES
8"
4"
60" MIN
B
1
1
*44" MIN
Y
NOTE:
Y=48" MIN IF DOOR
HAS CLOSER
60"
27" MIN
32" MIN
60"
2. REFER TO TYPICAL ACCESSIBILITY NOTES
SHEET (SECTIONS "R" & "U").
DIRECTIONAL SIGN AT
RESTROOM VESTIBULE
SILICONE
CAULKED
EDGES ALL
ROUND
8"
1 1/2"=1'-0"
X
24"
MIN
X
24"
MIN
1
23
1/4" = 1' - 0"
NOTE:
Y=54" MIN IF DOOR
HAS CLOSER
54" MIN
X
A. CONTRACTOR SHALL USE THE SIZE OF
THE WATER FOUNTAIN TO BE USED TO
SIZE THE ALCOVE ACCORDINGLY
(COMPLYING W/MFR REQUIREMENTS &
RECOMMENDATIONS) AS WELL AS
COORDINATING W/THE ARCHITECT.
36" MAX
NOTE:
Y=48" MIN IF DOOR
HAS BOTH A LATCH
& CLOSER
6"
48" MINIMUM
NOTE:
X=36" MIN IF Y=60"
X=42" MIN IF Y=54"
RADIUS
CORNER
15" MIN
RECESSED FOUNTAINS:
1. WITHIN ALCOVES MINIMUM 18" DEEP & 32"
MIN CLR WHEN A SINGLE FOUNTAIN IS
PERMITTED.
(CBC FIG.11B-5B)
1
8"
ADA SIGNAGE
30" MIN
28
SCALE
WHITE SYMBOL TYP
WHITE LETTERING TYP
(ENTRANCE)
B.O. VISUAL CHARACTERS
40" MIN ABOVE FINISH SURFACE
(PER 2013 CBC 11B-703.5.6)
ACCESSIBLE SIGNAGE AT ENTRY
60" OR LONGER
1-1/2" = 1' - 0"
ADA DOOR WIDTHS
PROPORTIONS
INTERNATIONAL
SIGN OF
ACCESSIBILITY
INTERNATIONAL SYMBOL OF ACCESSIBILITY:
12. STANDARD USED TO IDENTIFY ACCESSIBLE
FACILITIES.
13. WHITE FIGURE ON BLUE BACKGROUND, COLOR
#15090 ON FEDERAL STANDARD # 595A.
14. WHEN ENFORCING AGENCY DETERMINES, IF
APPROPRIATE, SPECIAL DESIGNS AND COLORS
MAY BE APPROVED.
CANE HITS POST OR
PYLON BEFORE
PERSON HITS OBJECT
ACRYLIC
PLASTIC
15090 IN FEDERAL STANDARD 595B).
36" MIN
SCALE
BLUE BACKGROUND (COLOR NO.
CONTINUOUS
POINT
HANDRAIL BRACKET
PASSAGE CLEARANCE
c
MEN
FIGURE (B)
FINISHED FLOOR
24"
MAX
ADA RAILING REQUIREMENTS
PLAN
Y
42"
MIN
B
Y
48" MIN
PLAN
AN ADULT SIZE WHEELCHAIR
AVERAGES 27 INCHES IN
WIDTH. THE REQUIRED 32
INCH CLEAR OPENING
ALLOWS 212 INCHES ON
EACH SIDE FOR HANDS.
Y
42"
MIN
A
RESTROOMS
1 "
2
TACTILE EXIT SIGNAGE AT ENTRY PER CBC 1011.4 & 11B-703.3
18 GA x 10" WIDE
ANCHOR PLATE
W/2" RETURN
BETWEEN STUDS
EDGE OF
TREAD NOSING
WOMEN
GRADE 2 BRAILLE, SEE NOTE 1-5
6" MIN
PIPE HANDRAIL
1'-0"
80" MIN
6" MIN
1'0"
WOMEN
27"
MAX
1
MEN
30"
10"
MAX
a
A
48" MINIMUM
CLEAR
DOUBLE DOOR
32" CLEAR
FINISH WALL
9
A Project for:
DOOR WIDTH PLUS 42"
CLEAR OPENINGS FOR TWO
LEAF DOORS MUST BE
BETWEEN EITHER DOOR IN
ITS 90 DEGREE OPEN
POSITION & THE EDGE OF
THE OTHER DOOR.
SECTION
b
3" = 1' - 0"
4" MAX
ACCESSIBLE SIGNAGE AT RESTROOMS
32" CLEAR
8"
5/8 " MIN. WHITE LETTERING
RAISED 1/32" TYP
GRADE 2 BRAILLE
3/8" TOGGLE BOLT
SEE PLAN
WHITE SYMBOL TYP
SINGLE DOOR
METAL
SLEEVE
AND LEVEL CHANGES (CBC FIG. 11B-5E(c) & (d), 11B-7B(b))
5
SIGN LOCATIONS:
9. ALL ACCESSIBLE ENTRANCES IDENTIFIED WITH
MINIMUM OF ONE STANDARD SIGN.
10. ADDITIONAL DIRECTIONAL SIGNS ALONG
ACCESSIBLE PATH OF TRAVEL ARE REQUIRED.
11. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE
SANITARY FACILITIES FOR PUBLIC USE SHALL
HAVE INFORMATION POSTED IN THE LOBBY AS
PART OF THE BUILDING DIRECTORY.
ANY AMOUNT
48" MIN.
D
SCALE
BLUE BACKGROUND ( COLOR NO.
15090 IN FEDERAL STANDARD 595B).
60" MAX.
C
SECTION
14
1/4" = 1' - 0"
THRESHOLD REQUIREMENTS
0"
EXPANSION SHIELD
a
LEVEL CHANGES
1'-
CLEAR OPENINGS MUST BE
BETWEEN THE DOOR IN ITS
90 DEGREE OPENING
POSITION & THE FACE OF
THE STOP.
112" MIN
METAL STUD
W/GYP BD EA SIDE
1/4" MAX
6" MIN
32" CLEAR
FACE OF
CONCRETE
1/4" MAX
ACCESSIBLE ACCESSORIES
SCALE
1/4" = 1' - 0"
7. SIGNS/PICTOGRAMS SHALL BE INSTALLED ON THE
WALL ADJACENT TO DOOR LEADING TO THE ROOM
OR SPACE THEY DESCRIBE AND @ 60" AFF TO
SIGN CENTERLINE & WHERE A PERSON MAY
APPROACH WITHIN 3" OF SIGNAGE W/OUT
ENCOUNTERING PROTRUDING OBJECTS OR
STANDING W/IN THE DOOR SWING AREA.
8. VERTICAL CLEARANCE @ SUSPENDED SIGNS
W/MIN HEADROOM OF 80" REQUIRE MIN 3"
CHARACTER HEIGHT MEASURED BY USING
UPPERCASE "X" CHARACTERS & NUMBERS SHALL
BE SIZED ACCORDING TO VIEWING DISTANCE
FROM WHICH READ. LOWER CASE CHARACTERS
PERMITTED.
1/2" MAX
THRESHOLD
B
SCALE
SIGNS / PICTOGRAMS
5. PICTOGRAMS/PICTORIAL SYMBOL SIGNS SHALL BE
ACCOMPANIED BY THE EQUIVALENT VERBAL
DESCRIPTION PLACED DIRECTLY BELOW THE
PICTOGRAM THE BORDER DIMENSION SHALL BE 6"
MIN HEIGHT.
6. CHARACTERS & BACKGROUNDS SHALL BE OF
NON-GLARE CONTRASTING COLORS.
TRANSITION BETWEEN FLOOR FINISHES
1
Seal:
LETTERS AND NUMBERS:
1. WIDTH TO HEIGHT RATIO BETWEEN 3:5 AND 1:1.
2. STROKE WIDTH TO HEIGHT BETWEEN 1:5 AND 1:10.
3. CONTRAST CHARACTERS & SYMBOLS
W/BACKGROUND.
4. SANS SERIF CHARACTERS.
COMPRESSED CARPET 1/4"
MAX BELOW THRESHOLD
C
ADA SANITARY FACILITIES (CBC FIG. 11B-1A)
112" MIN
GENERAL
RAISED
MOUNTING HEIGHTS - RESTROOM TOILET FIXTURES & ACCESSORIES
3"
MAX
10
1/2" MAX PILE HEIGHT
THRESHOLD
2
2'-6"
14" 8"
9"MIN
CLR # H/C
8" MIN KNEE CLEARANCE
THERMAL SHIELD @ HOT
6" MAX TOE CLEARANCE
WATER & DRAIN PIPES
ACCESSIBLE LAVATORY
ACCESSIBLE URINAL
NTS
ADA DOOR REQUIREMENTS
INTERNATIONAL
ACCESSIBILITY SYMBOL
29" CLR
34" MAX
40" MAX
2'-10"
4"
34" MAX
29" MIN
9" MIN
27" MIN
44" MAX
VALVE TO
FLUSH
1'-0"
7"-9"
MAX
33"-36"
40" MAX
19" MIN
18" 17"-18"
MAX.
7"9" MAX
3'-6"
MIN
SCALE
10" MIN
BOTTOM RAIL
OR PROVIDE
KICK PLATE
1 AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A15610- 1985 SLOW OPENING,
LOW-POWERED, AUTOMATIC DOORS SHALL 1985 SLOW OPENING, LOW-POWERED,
AUTOMATIC DOORS SHALL COMPLY WITH ANSI A15619-1984 DOORS SHALL TAKE AT LEAST
THREE SECONDS TO OPEN BEFORE BACK CHECKING AND NOT REQUIRE MORE THAN A
15-POUND FORCE TO STOP THE DOOR MOVEMENT THE DOOR-OPENING FORCE OF A
POWER-ASSISTED DOOR SHALL COMPLY WITH SECTION C-5212 ITS CLOSING SHALL
CONFORM WITH ANSI
FIN FLOOR EVEN
1'-0" x 1'-2" x 4" H
1/4" BENT STEEL
BARRIER CURB
18"
MIN
17" MIN
DETAIL
NOTES:
1. PROVIDE PRIVACY DOOR LOCK WHEN IT IS A PRIVATE TOILET OR FOR UNISEX USE
2. GRAB BARS (REFER TO ADA DETAILS & ADA NOTES SHEET)
TYPICAL (CBC FIG.11B-1A)
6 x 16 GA
BACKING
PLATE CONT EXTEND 1
STUD MIN
BEYOND
ATTACHMENT
33" -36"
2"
**
DIMENSION NOTES:
* A. 60" CLR MIN FROM LAVATORY EDGE TO THE FAR WALL.
A. 28" MIN CLR TO EDGE OF BOWL WHEN FLUSH VALVE WATER CLOSET OCCURS.
B. 28" MIN CLR BETWEEN LAVATORY TO FURTHEST PROTRUDING EDGE OF WATER
CLOSET.
** 48" MIN WHEN FRONT ENTRY DOOR OR 60" MIN WHEN SIDE ENTRY DOOR.
A
11
32" MIN
CLR
18" MIN
INTERIOR
Scale:
24" MIN
EXTERIOR
OF BLDG
Filename:
PARALLEL APPROACH
c
MAXIMUM SIDE REACH
OVER AN OBSTRUCTION
b
SIDE REACH LIMITS
HIGH AND LOW
24" MIN
* 48" MIN IF DOOR HAS BOTH
A LATCH & A CLOSER
LEVEL MANUEVERING DISTANCE
C AT DOORS LATCH APPROACH (CBC FIG. 11B-404.2.4.1)
SIDE REACH
(CBC FIG. 11B-306)
ADA REACH RANGES
FORWARD AND SIDE
SCALE
1/4" = 1' - 0"
16
D
ADA CLEARANCES
DOORS & CORRIDORS
Date:
Date
15.083.10
JA
-RN
-AS NOTED
03-11-15
--
Sheet Title:
TYPICAL
ADA
DETAILS
(FOR REFERENCE ONLY)
12"
MIN
PUSH SIDE
CLEAR FLOOR SPACE
2580 BELL ROAD
AUBURN, CA 95603
TA
9
18" MIN
CLR
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
TF
3S
TF
3
36" TO 42" LEVER OR
U SHAPED HANDLE
TENANT IMPROVEMENT
TA
17
TA
16
TA
2C
TA
2B
TA
2A
TA
2
TA
3D
TA
3C
TA
3B
TA
3A
TA
3
TM
1
18" MIN
CLR
WHEN 27" OR BELOW
TA
4
MISCELLANEOUS FIXTURES (TM)
RUBBER BUMPER
ON CHAIR
27"
MAX
TA
3B
IN
M LR
"
60 A C
DI
FLUSH ACTIVATOR
ON WIDE SIDE
WHEN HIGHER THAN 27"
TA
3A
TA
6
17"
MIN
RECESSED PAPER TOWEL DISPENSER (B 362)
30"x48" MIN CLR FLR SPACE
TA
5
42" MIN
GRAB BAR
24" MIN
SOAP DISPENSER (B 822)
TA
2A
DOOR TYPE:
1 MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, EITHER ATTACHED PANEL
OR BOTTOM RAIL
HARDWARE:
2 OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT
3 OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT REQUIRING GRASPING)
4 MOUNTED 36" TO 42"
5 MAXIMUM 85 LBS EFFORT TO OPERATE EXTERIOR DOOR, 5 LBS FOR INTERIOR
36" MIN
GRAB BAR
TA
1
12"
MAX
TOILET ACCESSORIES (TA)
18"
MIN
16"-18"
VESTIBULE
Sheet #:
DOORS IN SERIES (CBC FIG. 11B-404.2.6)
G-501
SCALE
1/4" = 1' - 0"
11
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION
A
B
C
36'-5"
56'-6"
12'-11"
10'-4" HOLD
11'-4"
12'-7" HOLD
1'-2"
3
03
03
08
09
04
06
OPENING AT 7-0" AFF AT FITTING AREA.
07
FIRE EXTINGUISHER - FIRE EXTINGUISHERS ARE TO BE TYPE 2-A MOUNTED AT
48" AFF MAX. PRIOR TO INSTALLATION, COORDINATE EXACT LOCATION &
QUANTITY WITH FIRE MARSHAL/INSPECTOR
08
INFILL OPENING FLUSH WITH EXISTING PARTITION TO MATCH ADJACENT
PARTITION CONSTRUCTION.
09
(E) RELOCATED ROOF LADDER
03
3
A
07
A-402
11
3'-0"
HOLD
C
(E OL.
)
07
4'-9"
09
RUE +
08
05
2'-10"
A Project for:
2
6
A-402
10
(E) 12"x12" WOOD COLUMN, TO REMAIN
11
(E) ROOF LINE
12
(N) FURRED OUT WALL, REFER TO WALL TYPE ON SHEET A-503,
FOR MORE INFORMATION
A
04
06
12'-4" HOLD
14'-7"
12'-4" HOLD
16'-5"
6
08
06
A-401
B
12'-0"
2
A-402
06
01
C
08
21'-6"
04
48'-1112"
D
08
4'-6" HOLD
A-402
04
20'-512"
A
2
2'-012"
12'-5"
03
4'-6" HOLD
02
37'-11"
05
11
2
STOCK
201
5
A-401
TENANT IMPROVEMENT
6'-4"
A-401
03
04
GFI
EXIT
CORRIDOR
200
5
20'-2"
05
A
08
10'-9" HOLD
4"
CASH WRAP - REFER TO SHEET 4/A-403 FOR DETAILS.
Seal:
09
12
04
GFI
05
01
01
14'-0"
01
ALIGN
1'-2"
1'-6"
TYP.
1'-2"
08
9'-11"
6'-912"
A-403
04
POWER POLE - EXTEND POWER AND DATA FROM CONDUIT ABOVE DOWN
POWER POLE TO CASH WRAP - SEE DETAIL 3A/A-403, AND ELECTRICAL
DRAWINGS FOR CASH WRAP POWER POLE REQUIREMENTS AND DETAILS
7
02
02
2
TOILET ROOMS - (E) TOILET ROOMS TO BE EXPANDED TO MEET ACCESSIBLE
CODES, REFER TO A-403 FOR ENLARGED PLAN AND DETAILS.
01
A-201
TOILET
ROOM
202
03
2'-5"
11
TOILET
ROOM
203
(E) & (N) ELECTRICAL PANELS AND EQUIPMENT - SEE ELECTRICAL DRAWINGS
JUNIORS
2
A-201
A
3'-0"
HOLD
10'-10"
04
4
A-401
3
07
09
04
06
13'-6"
A-402
10
12'-4" HOLD
1'-7"
4
A-402
XXX
WINDOW SYMBOL
- REFER TO SHEET A-601 FOR MORE INFORMATION
XXX
DOOR SYMBOL
- REFER TO SHEET A-601 FOR MORE INFORMATION
A
8'-4" HOLD
01
7'-212"
A-401
B
SALES AREA
100
10'-9" HOLD
A
92'-0" LEASE LINE
07
3
C
(E OL.
)
12'-4" HOLD
15'-0"
B
WALL TYPE SYMBOL
- REFER TO SHEET A-503 FOR MORE INFORMATION
A
C
TAREA
XXX
-
TYP.
90'-4"
1'-2"
B
SCALE
-
20'-0"
09
KEYNOTES
4
4
A-402
2'-012"
D
2
A-401
1
A-402
A
20'-1"
09
4'0"
2'-10"
09
6'-0"
4'-6" HOLD
1'-6"
01
18'-0"
LEGEND
SCALE
-
A
01
2
A-401
10'-4" HOLD
A
912"
612"
ETC
A-201
A-402
B
01
09
19'-3"
C
09
C
D
1
A-403
B
ADA
FITTING
01
C
9'-412"
1
A-401
12'-4" HOLD
D
1
GUYS
A-401
A
04
D
6
A-402
4.
GC IS REQUIRED TO COMPLETE A SITE VISIT PRIOR TO ANY BID SUBMISSIONS FOR
RUE2I PROJECTS. NOTIFY RUE21 CONSTRUCTION DEPARTMENT OF SCOPE OMISSIONS
OR DISCREPANCIES.
5.
GC SHALL VERIFY ALL FIELD CONDITIONS, LEASED SPACE DIMENSIONS, AND EXISTING
BUILDING ELEMENTS FOR COMPLIANCE WITH DRAWINGS BEFORE COMMENCING
CONSTRUCTION. GC SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR
HEIGHTS AND CONDITIONS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF RUE21 FOR RESOLUTION.
6.
ALL WOOD, WOOD BLOCKING, AND/OR MDF OTHER THAN FINISHED WOOD TRIM SHALL
BE FIRE RETARDANT TREATED.
7.
ALL METAL STUD PARTITIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.
8.
ANY EXISTING DEMISING WALL/SOFFIT SHALL BE DRY WALLED TO DECK AND SEALED
WITH APPROPRIATE APPROVED SYSTEM AS REQUIRED TO MAINTAIN I HOUR FIRE
RATING PER UL 263.
9.
FIRE RATED WALLS AND ANY PENETRATIONS MUST COMPLY WITH THE UL DETAILS U263
AND W-L-1001.
10.
RECONFIGURE AND RELOCATE EXISTING HEADS OF SPRINKLER SYSTEM AS REQUIRED
FOR NEW LAYOUT AND PROPER COVERAGE AS REQUIRED BY LOCAL ENFORCEMENT.
SPRINKLER VENDOR TO PROVIDE DETAILS DRAWINGS TO LOCAL MUNICIPALITY AND
LANDLORD'S INSURANCE UNDERWRITER FOR REVIEW AND APPROVAL
11.
WHERE FURRING IS EXISTING TO REMAIN, GC IS TO ENSURE THAT THE PARTITION IS
CONSTRUCTED WITH A MINIMUM 2 1/52" STUD TO ENSURE THAT TENANT TOGGLE
SYSTEM CAN BE INSTALLED. IF THE EXISTING FURRING IS SMALLER THAT THE MINIMUM,
REPORT FINDINGS TO RUE2I REGIONAL DIRECTOR OF CONSTRUCTION.
12.
FIELD VERIFY ANY WALL PENETRATIONS INCLUDING BUT NOT LIMITED TO COLUMNS
AND RELATED ITEMS. REPORT ALL FINDINGS TO RUE2I CONSTRUCTION DEPARTMENT
PRIOR TO CONSTRUCTION. ANY ADDITIONAL COST ASSOCIATED WITH CHANGES
REQUIRED DUE TO FAILURE TO REPORT FINDINGS SHALL BE THE SOLE
RESPONSIBILITY OF THE GC.
13.
SEE SHEET A-503 FOR WALL TYPES AND DETAILS
14.
SEE SHEET A-501 FOR TYPICAL FRAMING / BACKING DETAILS
15.
SEE DETAILS 11/A-503, A-502 FOR TYPICAL WALL, CEILING
12
01
01
08
08
ALIGN
5670 WILSHIRE BVLD. STE 1250
LOS ANGELES, CA 90036
Phone 323-965-1511
Revisions:
Description
Project No.:
Drawn By:
09
09
KORNWASSER SHOPPING
CENTER PROPERTIES, LLC
No.
04
B
C
11
ALIGN
A
09
G.C SHALL FIELD VERIFY ALL DIMENSIONS AND JOB CONDITIONS AND SHALL REPORT
TO THE RUE2I REGIONAL DIRECTOR OF CONSTRUCTION ANY DISCREPANCIES AND/OR
OMISSIONS WHICH COULD INTERFERE WITH THE SATISFACTORY COMPLETION OF THE
WORK HEREIN.
3
A-402
07
C
B
10
10
TYP.
2'-012"
1'-2"
06
09
A
2
3'-0"
HOLD
10'-4" HOLD
12
FITTING
AREA
101
3.
Reviewed By:
Date
15.083.10
JA
RN
Scale:
01
03-11-15
Date:
Filename:
1'-2"
B
B
05
1'-6"
08
A-402
4'-5"
A-402
44'-2"
04
D
1'-2"
D
9
D
1'-2"
5
4'-0" HOLD
4'-0" HOLD
A-201
4'-10" HOLD
5
13'-8"
A
11
4'-5"
A
07
4'-0" HOLD
3'-0"
01
4'-10"
4'-0" HOLD
4'-0" HOLD
07
4'-0" HOLD
4'-0" HOLD
C
06
DIMENSIONS ARE FROM FINISHED FACE OF DRYWALL TO FINISHED FACE OF DRYWALL
OR FACE OF CMU WALL, U.N.O. DO NOT SCALE DRAWINGS
912"
09
4'-6" HOLD
04
B
14'-7"
8
A-402
C
3'-0"
0"
D
2'-6"
612"
4'-
2'-10"
A
2
11'-1112"
D
2.
14'-0"
06
2'-10"
7
REFER TO G-102 FOR RESPONSIBILITY SCHEDULE
3
07
05
1.
3
A-402
04
A
11
C
35'-412"
17'-11"
B
23'-7"
3'-0"
HOLD
C
01
Client:
5'-1"
2'-10"
2580 BELL ROAD
AUBURN, CA 95603
1'-2"
11
03
02
CROSSROADS SHOPPING CENTER
RUE 21 - INTERIOR REMODEL
6'-1112"
STOREFRONT - (E) STOREFRONT TO REMAIN, ENSURE LIKE NEW CONDITION.
REWORK AS REQUIRED FOR NEW DOUBLE DOOR ENTRY. REMOVE SINGLE
DOORS AS SHOWN AND IN FILL TO MATCH EXISTING STOREFRONT.
37'-0"
14'-6"
6'-11"
01
Sheet Title:
1
4
9'-3" HOLD
4'-0" HOLD
1'-2"
11
22'-6"
14'-4" HOLD
11
A-201
14'-4" HOLD
PROPOSED
FLOOR PLAN
01
1'-2"
N
2'-5"
57'-6"
14'-1"
Sheet #:
71'-7"
A-101
73'-5" LEASE LINE
PROPOSED FLOOR PLAN
SCALE
1/4" = 1' - 0"
1
GENERAL NOTES
SCALE
-
C
MCG ARCHITECTS 2015 ALL RIGHTS RESERVED
NOT FOR CONSTRUCTION