6980 Wildridge Road BDK Colorado Springs, CO 80908 719-338-8672 Engineering, PLLC X See Consultant Review Action This submittal has been reviewed by Davis Partnership, P.C., where applicable, for conformance to architectural requirements, and has been reviewed by consultant(s) to Davis Partnership, P.C. for conformance with the design concept of the Project and compliance with the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; for information that pertains solely to the fabrication processes or to techniques of construction; and for coordination of the work of all trades. Refer to comments noted on the Consultant(s) review stamp(s) for further action. SUBMITTAL REVIEW Date: Project Name: Project Number: Division: Contractor: bdk453@q.com March 19, 2012 DAVIS PARTNERSHIP, P.C., ARCHITECTS Peak Vista Women’s Health 3/19/13 Date_________________ By______________________________ 12-01427 Plumbing GH Phipps / Rial Heating and Air Conditioning, Inc. Mark No Exception Taken Make Corrections Noted (Resubmit not required) Revise and Resubmit (or Submit) X X Action None Correct Resubmit The Consultant has reviewed and approved or rejected these contractor submittals, only for the limited purpose of checking for conformance with the design concept and the information expressed in the contract documents. This review does not include review of the accuracy or completeness of details, such as quantities, dimensions, weights or gauges, fabrication processes, construction means or methods, coordination of the work with other trades or construction safety precautions, all of which are the sole responsibilities of the contractor. Review of a specific item shall not indicate that the Consultant has reviewed the entire assembly of which the item is a component. The Consultant shall not be responsible for any deviations from the contract documents not brought to the attention of the Consultant in writing by the contractor. Notes: Well put together submittal; Thanks. UH-1: No Exception Taken. UH-2: No Exception Taken. EF-1: Make Corrections Noted. Coordinate with Electrical Contractor for variation in motor HP rom that which was specified. Manual Volume Dampers: Make Corrections Noted. Verify sizes need prior to ordering. Gravity Backdraft Damper: Make Correction Noted. Field verify existing duct size for damper, prior to ordering. GRD: Make Corrections Noted. Tag A: No Exception Taken. Tag B: Make Correction Noted. This is a 12x12 face diffuser and will need a plaster frame to install into an Acoustical ceiling tile that is more than 12” wide, but less than 24” wide. 1 Tag C: No Exception Taken. Hinged face is not required. Tag D: Make Correction Noted. Hinged face is not required. Grille returns to plenum, so needs largest square neck or no back panel. Tag E: Make Correction Noted. This is a 12x12 face grille and will need a plaster frame to install into an Acoustical ceiling tile that is more than 12” wide, but less than 24” wide. Tag F: No Exception Taken. Tag G: Make Correction Noted. Plaster frame will need to accommodate installation into a gyp board ceiling in Janitor Closet, Room 216 and in an Acoustical ceiling tile in Clean/Dirty, Room 221. Hinged face is not required. No Exception Taken. You may want to discuss this installation with the Krueger Manufacturer’s Representative, since round ceiling diffuser actually installs directly onto duct, so will not have outer ring fit flush to a ceiling surface. The adjustable cone may allow easy adaptation of airflow when adjacent ceiling does not exist. Review duct attachment method prior to ordering. Tag H: END 2