BROADBAND CATALOGUE ATP-300. One

advertisement
9
BROADBAND CATALOGUE
APARTMENT AMPLIFIERS
ATP-300. One-way, 862 MHz amplifiers - F connectors
• Forward path extends to 862 MHz. Passive return-path. Three available splits: 30/47 MHz,
42/54 MHz or 66/86 MHz.
• Push-pull technology: very low 2nd order intermodulation distortion.
• 1 RF input — 1 or 2 RF outputs.
• Continuous attenuation and equalization adjustments.
• Mains powering, 50/60 Hz. Electrical safety protection level: Class II. Mains lead with bipolar plug.
• External plastic box, dimensions: 125x85x55 mm. F type connection. Earthing facility. Wall fixing.
MODEL
REF.
Frequency range
MHz
ATP-332
ATP-322
3509
3489
2
(asymmetrical)
2
(symmetrical)
dB
14 (VHF) ,, 24 (UHF)
Gain adjustment
dB
-16 (VHF) ,, -12 (UHF)
Noise figure
dB
VAC
Consumption
W
15 ... 21
(fixed slope: 6dB)
18 ... 24 and 7 .. 13
(fixed slope: 6dB)
-10 (VHF/UHF)
4.5 (VHF) ,, 5.5 (UHF)
dBµV
Mains supply voltage
ATP-332
47 - 862
1
Gain
2
3488
40 - 318 and 470 - 862
No. of RF outputs
RF output level
ATP-302
(2x) 105
(2x) 108
111 and 100
230 - 240
2.3
2.5
If only one of the two outputs is being used, the spare port must be terminated with a CTF-125 (Ref. 1519) 75Ω terminator.
2
IMD3=-60 dB (DIN 45004B). The indicated level refers to the amplification of 2 TV channels. If more than 2 channels are used,
see Reduction table on Technical Annex.
1
ATP-900. Two-way, 2150 MHz Amplifiers - F connectors
• Terrestrial (TV) and satellite (IF) frequencies amplified separately. Passive return path.
• Single RF Input and Single RF Output with DC power passing capability.
• Adjustable gain for terrestrial frequencies.
• Mains powered 50/60 Hz. External plastic box. Wall fixing. Dimensions: 125X85X55 mm.
MODEL
REF.
General
Return
path
Satellite path
(FI)
Terrestrial path
(TV)
Frequency range
110
Terrestrial (TV)
Satellite (IF)
Return
dB
ATP-931
ATP-961
3490
3491
47 - 862
950 - 2150
5 - 30
86 - 862
950 - 2150
5 - 66
Nominal gain
dB
18
Gain adjustment
dB
-10
Noise figure
dB
≤7
RF output level
dBμV
108 (-60dB IMD3)
/
ATP-931
100 (-60dB IMD2)
Nominal gain
dB
18 - 24 (6 dB fixed slope)
Gain adjustment
dB
—
Noise figure
dB
≤ 10
dBμV
112
Through loss
dB
1.5
Operating temperature
˚C
RF output level
DC tansit
0 ... +45
24 V / 500 mA
Mains supply voltage
VAC
230 - 240
Consumption
W
3
9
BROADBAND CATALOGUE
APARTMENT AMPLIFIERS
ATB-100. One-way, 862 MHz amplifiers — Terminal-clamp connection
• 1 RF input — 1, 2 or 4 RF outputs.
• Variable input attenuator.
• Mains powered, 50/60 Hz. Electrical safety protection level: Class II. Mains lead with bipolar plug.
• ABS plastic box, dimensions: 105x60x38 mm. Terminal-clamp connection. Wall-fixing.
MODEL
ATB-181
ATB-122
ATB-124
1181
1182
1183
REF.
Frequency range
MHz
47 - 862
No. of RF outputs
Gain
dB
Gain adjustment
dB
Noise figure
dB
RF output level
dBµV
1
47 - 230
470 - 862
1
2
(symmetrical)
4
(symmetrical)
26
23
20
-20
ATB-122
ATB-124
-20 (only VHF)
5
104
(2x) 100
(4x) 96
Mains supply voltage
VAC
230 - 240
Consumption
W
2
IMD3=-60 dB (DIN 45004B). The indicated level refers to the amplification of 2 TV channels. If more than
2 channels are used, see Reduction table on Technical Annex.
1
LINE AND DISTRIBUTION CATV AMPLIFIERS
TSI-500. AC Power Supply / Power Inserter - RF configurable
The TSI-500 is a «power supply/power inserter» that may be RF configured as single inserter, 2-way splitter or 1-port tapoff. Inserts a 60 VAC voltage
to any of the coaxial cables connected to the unit —two cables when it is used as single inserter or three cables in the splitter or tapoff configurations.
The unit is presented in a tough aluminium die-cast housing for outdoor mounting. A neoprene compression gasket and a neoprne/metal-mesh
radiation gasket provide maximum RFI shieding and IP67 grade weatherproofing. RF ports are 5/8”-24 type.
MODEL
TSI-500
REF.
2179
Bandwidth
MHz
5 - 862
Nominal mains supply
VAC
230 - 240
Nominal inserted voltage (at max load)
VAC
58
Impedance
Ω
75
Return loss
dB
> 16
dB
(2x) 4.5
"single inserter" configuration
Max insertion loss
"splitter" configuration
0.6
"tapoff" configuration
1.6 and 12
Response flatness
dB
≤ ± 0.5
Max current to one RF port
A
5
Max current to all RF ports
A
5
Hum modulation
dB
≤ -70
Efficiency
%
90
Load regulation
%
0 ... -6
Screening factor
dB
> 80
Fuse/switch of AC injection
(3x) Semi-delay 6.3A / 250V
Fuse of transformer primary
T 3.15A / 250V
Fuse of transformer secondary
T 6.3A / 250V
AC requirements
VA
330
Operating temperature range
°C
-20 ... +70
Dimensions
mm
300x200x100
- Three fuses/switches for AC insertion to one, two, or the
three RF ports.
- Built-in protection for overcurrents.
- Input and output fuses with status LED indicators.
- Output overvoltage VDR protection.
- Wall fixing.
- Grounding and sealing facilities.
111
Related documents
Download