Commercial Storage Tanks

advertisement
Commercial Storage Tanks
FACTORY JACKETED AND
INSULATED STORAGE TANKS
These A. O. Smith storage tanks are designed for storing potable water.
Fitting locations are designed to meet the needs of normal installations plus
those for the A. O. Smith Cer-Temp 80 ® piping methods.
FEATURES
MODELS
TJ-80S, TJ-80A
TJV-120A, TJV-120M
& TJV-200M
TJV-120A
A. O. Smith storage tanks are ideal for
use with gas-fired copper heat exchanger
equipment for storage of any potable
water at temperatures up to 180°F.
GLASS LINED TANK - Alkaline
borosilicate composition permanently
fused to steel by firing at a temperature
of 1600°F, providing years of corrosion
protection and dependable use.
HEAVY GAUGE STEEL JACKET - With
baked enamel finish.
THREADED OPENINGS - All tanks
furnished with threaded openings for
thermometer, relief valve, 2” recirculation
lines, tankstat, and drain valve.
energy, helps reduce standby heat loss
TJ-80S
energy, helps reduce standby heat loss
TJV-120M
energy, helps reduce standby heat loss
TJV-200-M - 175 GALLONS
INSULATION - Storage Tanks meet or
exceed R12.5 minimum thermal insulation
requirements of the U. S. Department
of Energy and current edition of
ASHRAE/IESNA 90.1
TJ-80S, TJ-80A, TJV-120M and TJV-120A
with 200 gallons of storage.
120 Gallon Model
protection
protection
TJ-80A
energy, helps reduce standby heat loss
5 YEAR WARRANTY
If the tank should leak any time during
the first 5 years, under the terms of the
warranty, A. O. Smith will repair or replace
the tank. Installation, labor, handling
and local delivery are extra. For complete
information, consult the written warranty.
(FOR SELECT MODELS)
SUGGESTED SPECIFICATION
Storage tank shall be A. O. SMITH glasslined storage tank. Tank shall be ________ “ x ________ “ and have a nominal capacity of _________ gallons. Tank(s)
shall have threaded openings as shown on drawings. Interior of tank(s) shall be glasslined with an alkaline borosilicate composition which has been fused to the
steel by ring at a temperature of
. lass coating shall be continuous over the entire inner surface of the tank. Outer acket shall have a baked enamel
nish. Meets minimum thermal insulation re uirements of the .S. epartment of nergy and current edition of ASH A I S A
. . athodic protection shall
be provided. Tank shall have a working pressure of _________ psi. Tank shall have a ve year limited warranty as outlined in the written warranty.
Page 1 of 2
April 2015R
AOSTT35100
Commercial Storage Tanks
TJ-80A
TJ-80S
2" NPT
3/4" NPT
(ANODE)
1" NPT
2" NPT
3/4" NPT
(ANODE)
25 1/4"
2" ASME INSPECTION
OPENING (PLUGGED)
26 1/2"
2" NPT
FRONT & REAR
2" NPT
FRONT & REAR
ASME PLATE
UNDER COVER
54 7/8"
3/4" NPT
REAR
63"
3/4" NPT
REAR
42 3/4"
32 1/4"
51 7/8"
3/4" NPT
FRONT
47"
3/4" NPT
FRONT
19 1/2"
2" NPT
FRONT & REAR
16"
11" 9 3/4"
2" NPT
FRONT & REAR
3/4" NPT
REAR
7"
2" ASME INSPECTION
OPENING (PLUGGED)
3 3/4"
TJV-120M
3/4" NPT
REAR
TJV-120A
2" NPT
2" NPT
3/4" NPT
(ANODE)
1-1/4" NPT
(ANODE)
1" NPT
29 3/8"
28"
1" NPT
FRONT
2" NPT
FRONT
1" NPT
2" ASME INSPECTION
OPENING (PLUGGED)
ASME PLATE
LOCATED UNDER
COVER
62"
54 1/4"
3/4" NPT
50 1/2"
44 1/2"
TJV-200M
15"
11"
3/4" NPT
(ANODES)
4 1/8"
3 1/2"
2" NPT FRONT
61 3/4"
2" NPT
FRONT
42 1/4"
21 1/4"
9 3/4"
2" NPT
FRONT & REAR
2" NPT FRONT
& REAR
17 3/4"
10 3/4"
2" ASME INSPECTION
OPENING (PLUGGED)
3/4" NPT
FRONT
2" ASME INSPECTION
OPENING (PLUGGED)
2" NPT
32 "
1" NPT
3/4" NPT
2" NPT
77 "
64"
ASME RATING PLATE AND
HAND HOLE LOCATED
UNDER COVER
17 1/4"
12 1/4"
17 1/4"
12 1/4"
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
April 2015R
www.hotwater.com
Page 2 of 2
AOSTT35100
Download