Basic Multiple Breaker Company Switch Literature

advertisement

Features

 UL Listed

 NEMA 1 enclosure

 Powder coat finish

 Line feed to terminals on copper bus

 65K AIC @ 240V. circuit breakers

 Industry standard Series 16 Cam type receptacles

 Phase indicator lights

 Wire bending space as required by the NEC

 Built to customer requirements

Options

 Main breaker

 Dual Neutral receptacles

 Reverse Ground/Neutral Cams

 Parallel sets of receptacles

 Series 16 SafeCam™ receptacles

 Posi-Lok™ receptacle panels

 Pin & Sleeve ( IEC 309) receptacles

 Isolated Ground

 Service entrance rating

 Single phase 120/240V.

 Three phase 277/480V.

 Utility and Motor Branch circuits

 Digital Meter

 Custom laser engraved labeling

 Custom color

 Recessed, in-wall, mounting enclosure

 Pad / Freestanding enclosure

 Aluminum enclosure construction

 NEMA 3R construction

 NEMA 4 construction

 NEMA 4X construction

Product Bulletin No.: PBF-301B

Dual Breaker

Basic

Company Switch

600A. COMPANY SWITCH

30 4W + G

U NION C ONNEC TOR CO.

JACKSON VILLE, FL

WWW.UN IONCON NECTOR.COM

SAFE

PATENT No.: 7,151,23 4

AM

CABLE CO NNECTION

CONNECTIONS S HOULD BE MADE IN THE FOLLOWING ORDER:

1. EQUIPMENT GROUNDING CONDUCTOR (G)

2. GRO UNDED CIRCUIT CONDUCTOR (N)

3. UNGROUNDE D CONDUCTORS ( A, B, C )

DISCONNECTION SHOULD BE IN THE REV ERSE O RDER.

Jacksonville, FL ● Ph: 631-753-9550

PBF-301B-1

● Fx: 631-753-9560 ● www.unionconnector.com

Specifications

1.

Enclosure shall be NEMA 1 fabricated from 14 Ga. steel and powder coated black.

2.

Enclosure shall be provided with tabs for surface wall mounting

Product Bulletin No.: PBF-301B

Dual Breaker

Basic

Company Switch

3.

The dead front cover of the enclosure shall contain a windows with recessed panels that expose the circuit breaker handles. The top of the handles shall be below the plane of the dead front panel.

4.

Feed (Line) entrance shall be via conduit through the top of the enclosure to lugs on Main Breaker or Main Bus.

5.

Feed shall terminate either to terminals on main bus in units without a main breaker or to terminals on main breaker in units provided with a Main breaker.

6.

Service connection shall be through conduit to lugs on bus/breaker, sized for copper conductors as listed:

Amps Phase

60 #14-3/0

100 #14-3/0

Neutral

#14-3/0

#14-3/0

Ground

#14-2/0

#14-2/0

200 #3-350MCM #4-250MCM #14-2/0

400 #2-500MCM #4-600MCM #14-2/0

600 (2) 500MCM (2) #4-600MCM #14-2/0

800 (3) 500MCM (3) #4-600MCM #14-2/0

1000 (4) 500MCM (4) #4-600MCM (2) #14-2/0

7.

Main Bus shall be copper bar, sized 1 sq. in. in cross-section per 1,000A.

8.

The Main and sub breakers shall be a Listed, 3-pole, molded case type, with a current interrupt rating of 65k AIC at 240V.

9.

One set of red indicator lights shall be provided, per sub breaker to indicate phase voltage is available at the phase receptacles the respective sub breakers are protecting.

10. Company Switches with Series 16 Cam or SafeCam® type receptacles shall contain slots between each receptacle to eliminate hysteresis, as required by the NEC.

11. Company Switches with Posi-Lok™ type receptacles shall be provided with the outlet panel only.

12.

13. A warning label shall be permanently attached to enclosure, as required by NEC Art. 520-53k3. This label shall specify the proper sequence for connection and removal of cable plugs.

14. One (1) set of receptacles shall be provided for each branch breaker.

15. The receptacle panel shall contain slots between receptacles to eliminate hysteresis, as required by the NEC.

16. All connections from the main bus or breaker to the branch breakers and to the receptacles shall be by copper bus.

17. The Company Switch shall have the option to be suitable for rating as service entrance equipment.

18. The Company Switch shall meet or exceed all applicable NEC standards and shall be UL Listed. A label denoting the UL

Listing shall be permanently affixed to the unit.

19. The manufacturer shall provide a completely factory assembled, wired and tested Company Switch.

20. The Company Switch shall be a CSC type, as manufactured by Union Connector Co., Inc.

Jacksonville, FL ● Ph: 631-753-9550

PBF-301B-2

● Fx: 631-753-9560 ● www.unionconnector.com

Product Bulletin No.: PBF-301B

Dual Breaker

Basic

Company Switch

CATALOG

NUMBER

PBS-M2021W-CL

PBS-M2121W-CL

PBS-M4022W-CL

PBS-M4122W-CL

PBS-M604121W-CL

PBS-M614121W-CL

PBS-M8042W-CL

PBS-M8142W-CL

PBS-M2021W-SC

PBS-M2121W-SC

PBS-M4022W-SC

PBS-M4022W-SC

PBS-M604121W-SC

PBS-M614121W-SC

PBS-M8042W-SC

PBS-M8142W-SC

Standard Models

PART

NUMBER

FEED

AMP.

FEED

TYPE Main

BREAKERS

Branch 1 Branch 2

RECEPTACLE

TYPE

CSDC-20B21-CL

CSDC-2021-CL

CSDC-40B22-CL

CSDC-4022-CL

200A.

200A.

400A.

400A.

BUS

MAIN

BUS

MAIN

----

200A.

----

400A.

100A.

100A.

200A.

200A.

100A.

100A.

200A.

200A.

CSDC-60B4121-CL 600A. BUS ---- 400A. 200A.

CSDC-604121-CL 600A. MAIN 600A. 400A. 200A.

CSDC-80B42-CL 800A. BUS ---- 400A. 400A.

CSDC-8042-CL 800A. MAIN 800A. 400A. 400A.

Cam

Cam

Cam

Cam

Cam

Cam

Cam

Cam

CSDC-20B21-SC

CSDC-2021-SC

CSDC-40B22-SC

CSDC-4022-SC

200A.

200A.

400A.

400A.

BUS

MAIN

BUS

MAIN

----

200A.

----

400A.

100A.

100A.

200A.

200A.

100A.

100A.

200A.

200A.

SafeCam®

SafeCam®

SafeCam®

SafeCam®

CSDC-60B4121-SC 600A. BUS ---- 400A. 200A. SafeCam®

CSDC-604121-SC 600A. MAIN 600A. 400A. 200A. SafeCam®

CSDC-80B42-SC

CSDC-8042-SC

800A. BUS ---- 400A. 400A. SafeCam®

800A. MAIN 800A. 400A. 400A. SafeCam®

Options

SUFFIX

-PM

-RC

-3R

-4

-4X

DESCRIPTION

Pad / Freestanding enclosure

Recessed enclosure

NEMA 3R enclosure

NEMA 4 enclosure

NEMA 4X enclosure

-DN Dual Neutral (standard with 400A. breakers)

-RNG Reverse Neutral/Ground

-IG

-120

Isolated Ground

120V. Single Phase

-240

-480

-DM

120/240V. Single Phase

277/480V. 3-Phase

Digital Meter

Jacksonville, FL ● Ph: 631-753-9550

PBF-301B-2

● Fx: 631-753-9560 ● www.unionconnector.com

Download