Metalux D ES C R IPTION Catalog # SWLED is a versatile LED surface or wall mount luminaire which can be used in a broad range of commercial and industrial applications. This series provides customers with a high quality luminaire utilizing the latest LED, solid state lighting and electronic driver technology for optimal performance and maximized energy efficiency. Offered with three different lens distributions and three different lens options which provides uniform light distribution that is an ideal choice for general purpose lighting where customers want to move away from traditional fluorescent solutions. Type Project Comments Date Prepared by S PEC IFIC A TION FEA T U R E S Construction E me rg e n cy Ba ttery Pack Option Housing consists of die formed cold rolled steel with decorative white opaque injection molded end plates. Reflector/channel wireway cover secured by fasteners for easy wireway access. Channel back has numerous KO’s for easy installation. Optional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring codecompliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Controls The SWLED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the SWLED can include a factoryinstalled integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers (consult factory for 1% dimming), for use with Fifth Light controls. See ordering information for details on all three options. F in ish Highly reflective post painted finish (PAF) standard offering customers the optimal finish and handling. Additionally, each housing is treated in a multistage iron phosphate pretreatment, insuring maximum bonding and rust inhibitor. - LC (clear), LN (Semi-Frost with narrow distribution) and LW (full frost with wide distribution). This lenses provide different lighting distribution allowing customers to choice between smooth even illumination. Lens is securely held in place by removable injection molded white end caps that can be easily removed for installation and maintenance. Installation Fixture may be surface (wall or ceiling) and suspended mounted. See accessories below for ordering information. SWLED LED Compliance Sh ie ld in g Specially designed LED lens blends and linear optics allows us to offer three different lens versions Modules are UL recognized components and indoor luminaires are cULus listed for up to 40ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium™ Qualified and classified for DLC Standard, refer to www.designlights.org for details. Surface and Wall LED El e c t r i c a l Long-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3500K, 4000K or 5000K with a typical CRI 85. Projected life is 60,000 hours at 70% lumen output. Electronic drivers are available for 120-277V applications. A 0-10V dimming driver is standard. 4-11/16" [120mm] 4-1/2" [114mm] MOUNTING D A TA 2' CERTIFICATION DATA cULus - 1598 Damp Location Listed LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified NOM Compliant 21-3/16" [538mm] Lensed 4-11/16" [120mm] 28" [711mm] 4' 45-3/16" [1148mm] Lensed 4-11/16" [120mm] 52" [1320mm] Safe and convenient means of disconnecting power ADF142352 2015-09-29 14:27:51 S W LE D WATTA GE Lens Type Lumen Type Length Catalog Logic Nominal Lumens Wattage lm/W Full Frost (LW) Standard 2 ft. 2SWLED-LD1-8SL-LW-UNV-L8XX-CD1-SVPD2-U 800 10.1 105 Full Frost (LW) Standard 2 ft. 2SWLED-LD4-16SL-LW-UNV-L8XX-CD1-SVPD2-U 1600 18.9 99.5 Full Frost (LW) Standard 2 ft. 2SWLED-LD4-20SL-LW-UNV-L8XX-CD1-SVPD2-U 2000 23.5 92 Full Frost (LW) High 2 ft. 2SWLED-LD4-24HL-LW-UNV-L8XX-CD1-SVPD2-U 2400 24.9 94.5 Full Frost (LW) High 2 ft. 2SWLED-LD4-28HL-LW-UNV-L8XX-CD1-SVPD2-U 2800 29.1 89.5 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-16SL-LW-UNV-L8XX-CD1-SVPD2-U 1500 12.8 116.7 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-20SL-LW-UNV-L8XX-CD1-SVPD2-U 2000 17.6 113.6 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-28SL-LW-UNV-L8XX-CD1-SVPD2-U 2800 25.6 109.6 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-32SL-LW-UNV-L8XX-CD1-SVPD2-U 3200 30 101.7 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-36SL-LW-UNV-L8XX-CD1-SVPD2-U 3600 35.2 102.1 Full Frost (LW) Standard 4 ft. 4SWLED-LD4-40SL-LW-UNV-L8XX-CD1-SVPD2-U 4000 40.4 99.1 Full Frost (LW) High 4 ft. 4SWLED-LD4-44HL-LW-UNV-L8XX-CD1-SVPD2-U 4400 39.2 112.2 Full Frost (LW) High 4 ft. 4SWLED-LD4-48HL-LW-UNV-L8XX-CD1-SVPD2-U 4800 43.3 110.9 Full Frost (LW) High 4 ft. 4SWLED-LD4-52HL-LW-UNV-L8XX-CD2-SVPD2-U 5200 46.8 111.0 Full Frost (LW) High 4 ft. 4SWLED-LD4-56HL-LW-UNV-L8XX-CD2-SVPD2-U 5600 51.1 109.6 Full Frost (LW) High 4 ft. 4SWLED-LD4-60HL-LW-UNV-L8XX-CD2-SVPD2-U 6000 55.5 108.1 Full Frost (LW) High 4 ft. 4SWLED-LD4-64HL-LW-UNV-L8XX-CD2-SVPD2-U 6400 60 106.7 Full Frost (LW) High 4 ft. 4SWLED-LD4-70HL-LW-UNV-L8XX-CD2-SVPD2-U 7000 69 101.4 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF142352 2015-09-29 14:27:51 S W LE D PH OTOM ETR IC S 90˚ 75˚ 450 60˚ 900 45˚ 4SWLED-LD4-40SLLW-UNV-L835-CD1 Candlepower Electronic Driver 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Linear LED 3500K Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Lumens: 4087 1350 0˚ 15˚ Input Watts: 42.5W 30˚ Efficacy: 96.2 lm/W Test Report: 4SWLED-LD4-40SLLW-UNV-L835-CD1. IES C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 80% 30 70 50 117 105 95 86 78 72 66 61 57 53 50 117 99 85 74 66 58 53 48 43 40 37 117 94 78 66 56 49 43 39 35 31 29 70% 30 10 70 50 117 90 71 59 49 42 37 32 29 26 23 113 101 91 82 75 69 64 59 55 51 48 113 96 83 72 64 57 51 46 42 39 36 113 91 76 64 55 48 42 38 34 31 28 Angle Along II 45° Across ⊥ 1194 1203 1184 1153 1110 1058 996 926 849 766 678 588 495 400 302 207 125 55 4 1194 1188 1159 1123 1080 1032 978 918 855 786 713 639 564 491 419 352 291 236 188 1194 1173 1142 1110 1074 1031 983 933 878 816 754 690 626 563 503 445 390 337 285 20% 10 50 50% 30 10 50 30% 30 10 50 10% 30 10 113 87 70 58 49 42 36 32 28 25 23 106 90 78 68 60 54 48 44 40 37 34 106 86 72 61 53 46 41 36 33 30 27 100 85 73 64 57 51 46 42 38 35 33 100 82 68 58 50 44 39 35 32 29 26 94 80 69 60 54 48 44 40 36 34 31 94 77 65 56 48 42 38 34 31 28 26 106 83 67 55 47 40 35 31 28 25 22 100 79 64 53 45 39 34 30 27 24 22 94 75 61 51 44 38 33 29 26 24 21 0% 0 91 72 59 49 41 35 31 27 24 22 20 Zonal Lumen Summary Zone 0-30 Lumens 905 % Fixture 22.1 0-40 1480 36.2 0-60 2656 65.0 0-90 3738 91.5 0-180 4087 100.0 ORDER ING INFOR M A TION SAMPLE NUMBER: 4SWLED-LD4-40SL-LW-UNV-L840-CD1-SVPD2-U Length 2=2 ft. Length 4=4 ft. Length Series (13) SWLED=LED Surface and Wall LED Type LD4=LED 4.0 Voltage 347V=347 Volt (11) 480V=480 Volt (11) UNV=Universal Voltage 120-277 (1) UNC=Universal Voltage347/480 (4), (11) LED Lumens Output (2) 8SL=800 (3) 16SL=1600 (3) 20SL=2000 24HL=2400 (3) 28HL=2800 (3) 28SL=2800 (4) 32SL=3200 36SL=3600 40SL=4000 44HL=4400 48HL=4800 52HL=5200 (12) 56HL=5600 (12) 60HL=6000 (12) 64HL=6400 (12) 70HL=7000 (12) Optic LC=Clear Lens LN=Semi-Frost Lens - Narrow LW=Full Frost Lens - Wide Driver Type CD=0-10V Dimming Driver HDC=0-10V Dimming Driver (1% - 100% Dimming) (11) 5LTD=Fifth Light (DALI) Driver Number of Drivers 1=1 Driver 2=2 Drivers Packaging U=Unit Pack CD=0-10V Dimming Driver (10% - 100% Dimming) HCD=0-10V Dimming Driver (1% - 100% Dimming) (13) Options Occupancy Sensor ACCESSORIES SVPD1=Integrated occupancy and daylight dimming sensor, (Order Separately) 500 sq. ft. coverage (6), (8), (10), (15) SCF=Fixed Stem Set (Specify Length) SVPD2=Integrated occupancy and SCS=Swivel Stem Set (Specify Length) daylight dimming sensor, SCA=Adjustable 48" Stem Set 900 sq. ft. coverage (8), (14), (15) A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling SVPD3=Integrated occupancy and (Use 2 Per Fixture) daylight dimming sensor, 1200 sq. ft. coverage (7), (15) Emergency (4), (9) EL7W=7-watt, 120V-277V emergency battery pack installed (5) EL14W=14-watt 120V-277V emergency battery pack installed (5) CCT L835=3500K L840=4000K L850=5000K NOTES: (1) Not available when specifying emergencies, voltage must be specific. (2) Nominal lumen output. (3) 2 ft. model. (4) Only available in 4 ft. models. (5) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (6) For mounting heights up to 8 ft. (7) For mounting heights up to 30 ft. (8) For mounting heights up to 12 ft. (9) Integral EL battery pack is rated for 35°C. (10) Product configuration meet ADA. (11) Consult factory. (12) Currently not DLC listed, consult factory. (13) DesignLights Consortium™ Qualified and classified for DLC Standard (some models are not DLC qualified). Refer to www.designlights.org for details. (14) For wall mount applications. (15) For use with CD driver only. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. SH IP P ING D A T A Catalog No. Wt. 2SWLED-LD4 4SWLED-LD4 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. 6 lbs. 12 lbs. ADF142352 2015-09-29 14:27:51 S W LE D INTEGRA TED S ENS OR Des c r i p t i o n This innovative luminaire-integrated sensor control system is optimized for code-compliant occupancy detection and daylight harvesting – all from within the foot print of Metalux’s award-winning recessed ambient luminaires. N o N ew W i re s An in-place fixture retrofit is all that’s needed to meet most energy codes in commercial spaces. The sensor system is factory wired to the luminaire, switching on or off based on occupancy, and dimming the light when enough daylight is available. S ophi s ti c a te d l i g h t i n g co n tro l with o u t co mmissio n in g The luminaire-integrated sensor system offers out-of-the-box operation using thoughtful default settings. Fl exi bi li t y a n d I n d i v i d ua l Co n tro l When the application demands more, the sensor system has the option to make changes using a remote control. The remote allows changes from the default settings for occupancy, target light level, preset lighting levels, and more. C os t -effe c t i ve , S t a n d - a lo n e Op e ra tio n With a single product to mount and a single electrical connection to make, the Metalux luminaire with an integrated sensor system saves money on the total installed cost when occupancy or daylight harvesting controls are needed. The integrated sensor system works stand-alone, without the need for additional switches and dimmers. When manual-on, manual dimming or other code-required control schemes are needed, please see the comprehensive offering of Greengate and Fifth Light solutions from Cooper Controls at www.coopercontrol.com. M et al ux I n t e g r a t e d S e n so r Se q u e n ce o f Op e ra tio n The SWLED Metalux luminaires are available with an optional integrated sensor capable of occupancy sensing and dimming daylight harvesting. The sensor is preinstalled and factory wired, simplifying the installation of a complete, code-compliant lighting system. The occupancy sensing portion of the sensor uses Passive Infrared (PIR) technology with Auto-on/Auto-off operation. The lens in the center of the sensor directs the view of a heat detector component into multiple zones to sense the heat emitted by occupants moving through the room. The sensor is preset to go between full on and 50% brightness, never leaving the area dark. To trigger the light to full on, an occupant must move from one zone to another. When motion through the various zones ceases, the sensor logic concludes the room is unoccupied, and begins a count-down timer. By default, the timer is factory-set to 20 minutes, and can be adjusted to 5, 10, 15 and 20 minute increments using the optional remote control, model number HHPRG-MS. Any motion detected between zones during the stop the timer and the light will remain on. When motion is detected, a red LED located behind the lens will blink. In addition to the default on/off function, the sensor has an Energy Saver feature, where the light can be set to dim to a preset level after half of the count-down timer, and when no further motion is detected to the remainder of the count-down, the light will shut off. The Energy Saver feature preset level and feature are configured using the optional remote control. See the Sensor Programming Guide that comes with the HHPRG-MS remote for details on this feature. The red LED indicator will also blink repeatedly to confirm any programming change. The daylight harvesting portion of the sensor uses a small photoreceptor behind the occupancy sensing lens. The sensor continuously measures the available light in the room, even when the fixture is turned off. This allows sensor to operate in one of three daylighting modes, where the artificial light from the paired Metalux luminaire can be set to dim or brighten based on the amount of available light from surrounding natural and artificial light. Since the sensor measures light from its luminaire along with other light sources, this sensor follows a closed-loop daylight harvesting style. The first mode, Daytime, is active when the sensor detects light of at least 100 lux in the room. In Daytime mode, when the light is turned on after detecting occupancy, the sensor will begin balancing the luminaire light level relative to the total available light it measures. The default light balancing target is 500 lux. This level can be adjusted higher or lower using the optional HHPRG-MS remote, pressing “SET” and then pressing the “DO” (Daytime Occupied) button. The Daytime Unoccupied, “DU” has a default of level of 50% to prevent the lights from turning off completely when unoccupied. More details on this function are found in the Sensor Programming Guide for the HHPRG-MS remote. The next two modes, Twilight and Nighttime, function in a similar way, allowing the artificial light to dim or brighten to different levels based on the surroundings. While primarily for use in outdoor luminaires, these modes are available for use in areas with a wide range of natural light, including atriums, day lit stairwells, and rooms with large or continuous windows. The Twilight mode is active when the sensor detects 50-100 lux in the off position, and has a 300 lux default light balancing target. The Nighttime mode is active when the sensor detects less than 50 lux, and has a 250 lux default light balancing target. Like the Daytime mode, there are separate settings for Twilight Occupied (“TO”), Twilight Unoccupied (“TU”), Nighttime Occupied (“NO”) and Nighttime Unoccupied (“NU”) which can be adjusted and set using the optional HHPRG-MS remote. In addition to use for programming the sensor, the optional HHPRG-MS remote can be used to override the functions of the sensor temporarily. The remote has raise/lower buttons to adjust the light level for special tasks, as well as a power button to turn the lights on or off. Unless the SET button and another function is selected, any changes made using these buttons will revert to the programmed settings after the sensor has not detected occupancy for its programmed time, turned to “Off” mode. At the next detection of occupancy, the sensor will revert to its programmed settings for count-down timer and light balancing. C over ag e P a t t e r n s n e x t p a g e Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF142352 2015-09-29 14:27:51 S W LE D S ENSOR D ETA ILS - S W LE D SVPD1 Coverage Pattern Coverage 4m [12 ft.] Top View CL Side View 3.3m [10 ft.] 0m [0 ft.] 0m [0 ft.] 4m [12 ft.] 0m [0 ft.] 4m [12 ft.] Reccomended Mounting Height 8–12 ft. 4m [12 ft.] Major Motion SVPD2 Coverage Pattern Top View CL 9.1m [30 ft.] 6.1m [20 ft.] 4.5m [15 ft.] 3m [10 ft.] 1.5m [5 ft.] Side View 0 0 2.4m [8 ft.] 1.5m [5 ft.] 3m [10 ft.] 4.5m [15 ft.] 6.1m 4.5m 3m 1.5m 0 1.5m 3m 4.5m 6.1m [20 ft.] [15 ft.] [10 ft.][5 ft.] [5 ft.][10 ft.][15 ft.] [20 ft.] 9.1m [30 ft.] 6.1m [20 ft.] 9.1m [30 ft.] Optional Remote Control R Lo aise we / r SVPD3 Coverage Pattern 5 LO Side View T e NU ET Pr og ra HH 9.1m [30 ft.] 20 NO TU sS 6.1m [20 ft.] 15 ES TO DU Sc To n an sav es : d se e sc lec en t s es ce pre ne s 10 HI SE DO 0 Tim Ou e t m m PR ing Re G- mote M S 12.2m 9.1m 6.1m 3m [40 ft.] [30 ft.] [20 ft.] [10 ft.] 0 3m 6.1m 9.1m 12.2m [10 ft.] [20 ft.] [30 ft.] [40 ft.] Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. HHPRG-MS Remote ADF142352 2015-09-29 14:27:51