INSTRUCTIONS Retrofit Installation Instructions •Warning - Risk of fire or electric shock. LED Retrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electriction. •WARNING - Risk of fire or electric shock. Install these kits only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. Easy Install in Under 60 Seconds •LED Retrofit Luminaire is designed for installation in standard 5”-6” recessed downlight housing. •Recommended dimmer: Lutron and Leviton •Compatibility of housing not on this list can be determined by measurement of the housing as detailed in the attached drawing (Figure 1) •WARNING - Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component. •WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. •Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. 5-6i n c h •CAUTION: Shock and fire hazard, do not use when enclosure is broken. •Suitable for use in enclosed recessed luminaires. •Min. lamp compartement dimensions: 5” (D) x 5.5” (H) x or 6” (D) x 5.5” (H) where D is minimum diameter and H is minimum height of the listed recessed luminaire compartment, as applicable. This recessed luminaire has a E26 Edison screw-base and is UL listed for installation and shallow recessed housing series. •Suitable for damp locations. Compatible for 5 inch Can: HALO: LED Can: H550ICAT, H550RICAT 1. Before starting installation, please read this leaflet and keep it for future reference. 2. To avoid possible electrical shock, be sure that the power supply is turned off at fuse box or circuit breaker before installing or servicing fixture. 3. During installlation do not let the product surface rub against other hard objects or drop on the floor, otherwise the product will be damaged. 4. Risk of fire: supply conductors (power wires) connecting the fixture must be rated a minimum of 90˚C. If uncertain consult with an electrician. 5. The luminaire must be securely mounted; the bare wires of the power cord must be properly insulated to prevent electrical hazards. 6. For indoor use only. Suitable for damp locations. Avoid contact of water and other liquids with the light and power supply to avoid leakage and electric shock. 7. Before the installation of any recessed lighting luminaire, check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting. 8. Protect the light from dust and dirt when painting or during construction. 9. Clean with a soft damp cloth only, do not use any chemical cleaners. 10. The luminaire light can be dimmed a with standard triac dimmer. 11. Input: 120VAC 60Hz POWER: 11w/15w CFLC an: H524ICAT, H524RICAT, H570ICAT, H570RICAT, H571ICAT, H572ICAT, H572RICAT, H573ICATLD, H573RICATLD, H51CAT, H5RICA, H5T, H5RT ALL-PRO: Incandescent Can: EI500RAT, ET500, ET500R. Juno: TC20R, TC20S, TC20, IC20R, IC20N, IC20NW,IC20S, IC20W, IC20, IC25R, IC25W, PL526RE, ICPL526REN, ICPL518E Compatible for 6 inch Can: HALO: LED Can: H7ICT, H7ICAT, H7ICATNB, H7RICAT, H7RICT, H7UICAT, H7UICT, H750RICAT, H750ICAT, H27ICAT, H27ICT, H27RICAT, H27ICT, H27RICAT, H51CAT, HRICAT, H750TCP ALL-PRO: Incandescent Can: EI700, EI700AT, EI700ATNB, EI700NB. EI700RAT, IE700U, EI700 UAT, EI2700, EI2700AT, EI500AT, EI500RAT Juno: IC22, IC22R, IC22W, IC22S, IC23, IC23W, IC21, IC21R, IC25, IC25W, IC25S For additional product and ordering information, please refer to the latest manufacturer specification. PG 1 FUSELED.COM 800 752 1660 1740 EMERSON AVE OXNARD, CA 93033 INSTRUCTIONS Retrofit Installation Instructions In s ta lla tio n i n to H o u s in g s : FIG.1-1 FIG.1-2 1. Loosen torsion spring bracket with screw. If install into 6” can housings: Remove 2 torsion spring brackets completely to keep them in the outward position. (FIG. 1-1) If install into 5” can housing: Slide bracket to inward position. (FIG. 1-2) Then, tighten screw. 2. Unscrew the wing nut inside the can to detach the socket bracket from the can. Disengage the socket from the socket bracket. (FIG. 2) 3. Thread the socket adapter into the socket. (FIG. 3) 4. Plug the female connector of the retrofit trim into the male connector of the socket adapter assembly. (FIG. 4). 5. Squeeze both torsion spring arms together and insert into the torsion spring slots (or retainer brackets) of the can. Tuck all wires into the can and carefully push the retrofit trim into can (note: to provide enough room in shallow cans, carefully position socket adapter and socket adjacent to the long side of the LED driver prior to inserting the retrofit trim into the can. (FIG. 5) R e pla c ing L ED Lu m in a ir e s : 1. With fingertips, pull down firmly on trim ring until module stops. 2. Squeeze torsion springs together to remove LED module. FIG.2 FIG.3 3. Disconnect LED module wiring from recessed can (LED Connector or screw in Edison base.) D im m in g : The LED luminaire can be dimmed with amany standard incandescent dimmers, however, an electronic low voltage version of a standard dimmer (with neutral connection is recommended for many applications. Updates in dimmer technology and special conditions may apply depending on the dimmer type being used. To be assured of the latest information regarding luminaire and dimmer compatibility, please contact dimmer manufacturer. E le c tr ic a l Co n n e c tio n : N AC120 L Dimmer FIG.4 FIG.5 Downlight Downlight Downlight GND P a c k in g L is t: 1. LED luminaire (with LED driver) 2. #18 Black/White connecting wire with E26 lamp holder (for L/N input) W a r r a n ty : We offer a 5 year limited warranty. As with any electrical installation, a qualified electrician must ensure compatibility of use with a particular housing; this includes all applicable national and local electrical and building codes. Installer is responsible for securely retaining the LED module in a housing at time of installation. PG 2 FUSELED.COM 800 752 1660 1740 EMERSON AVE OXNARD, CA 93033