PRODUCT DATASHEET HB078-1-04S3-S3F HYBRIFLEXDirect, Cabling Solution for 3 RRU Technical Features STRUCTURE Cable Type Size Fire Performance 3 RRU HYBRIFLEXDirect 7/8" Flame Retardant, LSZH MECHANICAL SPECIFICATIONS Outer Diameter Nominal Cable Weight Minimum Bending Radius, Single Bend Minimum Bending Radius, Multi Bends Tensile Strength Recommended / Maximum Clamp Spacing mm (in) kg/m (lb/ft) mm (in) mm (in) N (lb) m (ft) 27.8 (1.09) 0.79 (0.53) 120 (4.7) 250 (9.8) 700 (157) 0.8 / 1 (2.75 / 3.3) DC POWER CABLE SPECIFICATIONS HYBRIFLEX Series RFS' HYBRIFLEXcabling solution for Remote Radio Unit (RRU) combines optical fiber and DC power in a single lightweight aluminum corrugated cable, making it the world's most innovative solution for RRU deployments. It was developed to reduce installation complexity and cost at Cellular sites. HYBRIFLEXcabling solutions allows mobile operators deploying RRU architecture to standardized installation process and eliminates the need and the cost for an internal grounding wire. The HYBRIFLEXcable is part of a site installation kit. It consists of an armored bundle of 3 shielded DC cables, 3 F/O distribution cables and a rip cord to adjust the breakout part of the cable. Number of DC Pairs Maximum DC-Resistance Power Cable Cross Section of Power Cable Shielding DC Wire Jacket Material DC Wire Jacket Thickness DC Cable Single Bending Radius DC Cable Diameter DC Cable Jacket DC Standards (Meets or Exceeds) 3 ȍkm ȍkft) 4.95 (1.51) mm² (AWG) 4 (12) braid Polyethylene, PE, Metalhydroxite Filling mm (in) 0.5 (0.02) mm (in) 100 (3.94) mm (in) 9.9 (0.39) UV stable black PE IEC 60228 CABLE JACKET UV-Protection Individual and External Jacket Jacket Material Yes UV stable black PE ARMOR SPECIFICATIONS FEATURES / BENEFITS A corrugated armor with excellent bending characteristics minimizes installation time and enables mechanical protection and EMC shielding Outer conductor grounding eliminates typical additional grounding requirement and saves on installation costs Lightweight solution and compact design decreases tower loads Robust cabling eliminates need for expensive cable trays and conduits Installation of stripped fiber optic cable pairs directly to RRH reduces CAPEX and wind load by eliminating need for junction boxes F/O and DC housed in single corrugated cable saves CAPEX by standardizing RRH cable installation and reducing installation equipments Armor Type Maximum DC-Resistance of Armor Copper Equivalent Cross Section of Armor Diameter Corrugated Armor Corrugated Aluminum tube ȍkm ȍkft) 1.21 (0.37) mm² (AWG) 16 (5) mm (in) 25.2 (0.99) F/O CABLE SPECIFICATIONS F/O Cable Type Number of F/O Pairs Core/Clad Secondary Protection Nominal Single Bending Radius Cable Diameter F/O Cable Jacket F/O Standards (Meets or Exceeds) µm µm (in) mm (in) mm (in) Tight-Buffer, Singlemode 3 9 /125 900 (0.035) 50 (1.97) 4.8 (0.19) UV stable black PE ITU G 657.A2 TESTING AND ENVIRONMENTAL Storage Temperature Operation Temperature Installation Temperature Jacket Specifications °C (°F) °C (°F) °C (°F) LSZH Specification -40 to 85 (-40 to 185 ) -40 to 85 (-40 to 185 ) -20 to 50 (-4 to 122 ) IEC 60332-3-24, UL 1581.sec.1080 IEC 60754-1 / 2, IEC 61034-1/2 Product Detail HB078-1-04S3-S3F REV: B All information contained in the present datasheet is subject to confirmation at time of ordering REV DATE: 12. August 2014 www.rfsworld.com Page 1 of 2 PRODUCT DATASHEET HB078-1-04S3-S3F HYBRIFLEXDirect, Cabling Solution for 3 RRU External Document Links Notes Handling Instruction.pdf Ordering_code.pdf Solution Overview_1.pdf Solution Overview_3.pdf HB078-1-04S3-S3F REV: B All information contained in the present datasheet is subject to confirmation at time of ordering REV DATE: 12. August 2014 www.rfsworld.com Page 2 of 2