Ascent LED
Downlight Module
®
FIXTURE TYPE
CATALOG
NUMBER
Features
The Ascent® LED downlight module fits into a 6” IC and Non-IC new
construction, remodel and retrofit recessed cans. With the LED
driver mounted to the top of the die-cast, the total height of the
unit is 4.94” (125.6mm). The Ascent® LED’s 600 lumens at
13.7W surpass the performance of a 65W BR30 incandescent
lamp and the 18W CFL system.
Optical
Guaranteed single binning color consistency with enhanced
illumination uniformity. Available in 3000K and a CRI = 84.
The specular aluminum reflector is to optically control light output.
Light distribution uniformity within ±60 degree beam angle.
Construction
The downlight module design utilizes a durable die-cast aluminum
heat sink assists in the thermal management keep the system cool
to achieve the 50,000 hours at 70% lumen maintenance.
Electrical
The 120V, 50/60Hz high efficiency LED driver has a power factor
(PF) 0.92. Operating temperature range is -20°C (-4°F) to
50°C (122°F). Dims down to 10% light output with approved
dimmer. American Fluorescent provides a 3 year limited warranty
only when used with approved IC cans, Non-IC cans and
120V compatible dimmers.
Lamping
Meets ENERGY STAR® SSL standards. Guaranteed single
binning color consistency with enhanced illumination uniformity.
3000K, 84 CRI.
Life
Rated for 50,000 hours at 70% lumen maintenance.
Certification
Meets ENERGY STAR® SSL standards for commercial and residential
Title 24 compliant
cULus Listed – damp location
RoHS
Ordering Information for Ascent® LED
Use guide below to order complete fixture. Example: L606M30S1D-6WRWT
L
60
6M
30
Model #
Lumens
Aperture
CCT
L = LED
60 = 600
6M = 6” Module
30 = 3000K (STD)
S
-
1
D
6
WRWT
Connection
Voltage
Dimmable
Trim/Reflector Size
Trim/Reflector
S = Edison Base Socket
G = GU24 Socket
1 = 120V
D = Dimmable
6 = 6”
WRWT = White Reflector/
White Trim
For photometric information, consult factory.
Specifications and dimensions subject to change without notice.
2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • www.americanfluorescent.com
R0/11
L606M Series
Installation Guide
Safety Precautions:
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property
instructions could result in potentially fatal electric shock and/or property damage. It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes. Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 110‐120VAC, 60Hz fused circuit. To reduce the risk of electrical shock and to assure proper operation this
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel. This fixture is intended to be used for general indoor lighting in dry or damp locations only.
• Do not attempt to install or use the L606M series until you read and understand the installation instructions and safety labels.
• Verify power is off before installing or uninstalling.
• Do not use the L606M if the lens, housing, or power cables are damaged.
• The L606M series has line voltage risk of shock and no user serviceable parts. Do not attempt to open them.
• Do not exceed the specified voltage and current input (refer to the specification sheet).
• Do not hot swap L606M.
Do not hot swap L606M.
• Avoid looking directly into the light beam as the high brightness beam may damage the eyes.
• Ascent three year limited warranty applies only to Ascent LED brand products. To reference the complete warranty statement, please refer to the latest Ascent LED L606M series specification sheet by visiting the American Fluorescent website at www.americanfluorescent.com .
• THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
• WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings
• Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation
electrical components during kit installation
• WARNING – To prevent wiring damage or abrasion, do not pinch or damage exposed wiring during installation. Keep away from edges of sheet metal or other sharp objects
REQUIRED COMPONENTS
System Part Number example: L606M30S1D‐6WRWT b
l
Edison Connector Part Number: S
(3000151 ‐ included)
Ascent LED
Part Number: L606M30S1D
GU 24 Connector Part Number: G
(3003005 ‐ optional)
Reflector and trim assembly
Example of Part Number: 6WRWT (included)
Individual Components:
White trim ring
(1060518)
Silver reflector
Silver reflector
(1030122)
White reflector
(1030123)
LED Driver Part Number
(2003106)
IInstructions
t ti
1. Preparing for installation
A. Disconnect electrical power before installing or servicing any part of this fixture. B. Remove fixture from its package. 2.
Connect the Edison style connector (S) to the L606M. Please retain these instructions for maintenance reference.
2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • www.americanfluorescent.com
8060565 R6
Page 1
L606M Series
Installation Guide
4. Squeeze torsion springs together and install into torsion spring brackets inside recessed housing.
3. Remove existing trim and CFL/Incandescent lamp to reveal the screw‐in Edison style socket. Remove socket from plate. Connect the Edison style connector to the revealed socket . To prevent the wires from twisting during this process, rotate the L606M in the same direction as the Edison connector is screwed in.
g
NOTE: If housing does not have torsion spring receivers, replace housing with one that is compatible with the L606M series (see complete list below).
NOTE: If a GU24 socket is present, a GU24 (G) connector will be required. 5.
Carefully route wires into fixture and push L606M up, flush with
ceiling surface.
6.
Turn power on.
3 YEAR PRODUCT LIMITED WARRANTY
American Fluorescent Corporation (The Company) warrants the LED L606M series and lighting sources
against defects in material or workmanship for a period of three years from date of original purchase,
and the Company agrees to repair or, at the Company's option, replace a defective product without
charge for either replacement parts or labor during such time.
time This does not include labor to remove
or install fixtures. This warranty is extended only to the original purchaser of the product. A
purchaser’s receipt or other proof original purchase acceptable to the Company is required before
warranty performance shall be rendered. This warranty only covers product failure due to defects in
materials or workmanship, which occur during normal use. It does not cover the failure of product
caused by accident, misuse, abuse, lack of reasonable care, alteration, faulty installation, acts of
nature, subjecting the product to any but the specified electrical service or any other failure not
resulting from defects in materials or workmanship. Damage to the product caused by separately
purchased, non‐Company supplied, or non Company qualified components as well as corrosion or
discoloration of components are not covered by this warranty. There are no express warranties
except as described above.
ALL IMPLIED WARRANTIES, IF ANY, INCLUDING IMPLIED WARRANTS OF MERCHANT ABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE DURATION OF THIS
EXPRESS WARRANTY. The exclusions or limitations allowed by law may vary from state to state.
The Company authorizes no other warranty, written or verbal. This warranty provides specific legal
rights, and other rights, which vary from state to state, may also apply. To obtain warranty service,
please call American Fluorescent Corporation at 847.249.5970 and provide product information, the
issue, contact name, contact address and telephone number. You will be contacted with a solution or
a Return Goods Authorization number and full instructions for returning the product. The Return
Goods Authorization (RGA) Number issued by the Company must accompany products and must be
returned freight prepaid. Any product received without a Return Goods Authorization Number from
the Company will be refused. The Company is not responsible for merchandise damaged in transit.
Repaired or replaced products shall be subject to the terms of this warranty and are inspected when
packed. Evident or concealed damage that is made in transit should be reported at once to the
carrier making the delivery and a claim filed with them.
THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL,
INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM THE USE OF THE PRODUCT OR A RISING OUT OF ANY BREACH OF THIS WARRANTY.
The L606M is designed to fit the following housing:
Capri Lighting
CR1, QL1, PR1
ELCO EL7IC, EL7ICA, EL7IC100A,
EL7RICA R10H RR10H
EL7RICA, R10H, RR10H Halo H7ICT, H7ICAT, H7RICT, H7ICTNB, H7ICATNB, H7T, H7RT, H7TNB, H7UICT, H7UICAT, H7RICAT, ET700, EI700R, EI700, EI700AT, EI700NB, EI700ATNB, ET700R, EI700RAT, EI2072RAT, EI2072AT, EI700U, EI700UAT Juno IC22, IC22R, IC2, TC2 Lithonia LC6 Prescolite DBX, DBXQC, RMNICD, RMNICDAT, IBXHW
Thomas PS1
PS1 The following dimmers have been tested and approved to dim the L606M:
Cooper (Part Numbers)
Aspire ( 9530XXX)
Leviton (Part Numbers)
Illumitech (IPI06‐XXX)
Trimatron (6602‐X , 6681‐X, 6683‐X, 6684‐X, 700‐X & 705‐X)
SureSlide (6631)
True Touch (6606‐1LM)
Acenti (ACE06‐XXX)
Vizia (VZE04)
Lutron (Part Numbers)
Skylark (S‐600, S2‐LH)
Maestro (MAW‐600)
Nova T (NTELV‐600)
Faedra (FAELV‐500‐XX)
For additional information on housings and dimmers, refer to the L606M information at www.americanfluorescent.com .
Please retain these instructions for maintenance reference.
2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • www.americanfluorescent.com
Page 2
Recommended 120V Compatible Dimmers for Ascent® LED
Manufacturer
Lutron
Brand Name
Skylark®
Nova T®
Maestro®
Faedra®
Illumitech
SureSlide
True Touch
Acenti
Vizia
Leviton
Trimatron
Part Number
S-600P
NTELV-600
MAW-600
FAELV-500-XX
IPI06-XXX
6631
(6606-1LM)
ACE06-XXX)
(VZE04)
6602-X
6681-X
6683-X
6684-X
700-X
705-X
Maximum†
Ascent® LED / dimmer
43
43
43
36
43
43
43
43
29
43
43
43
43
43
43
† Maximum load of Ascent LED / dimmer based on full dimmer rating prior to de-rating of dimmer for multiple
devices ganged together.
2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • www.americanfluorescent.com
1/1/11
Approved Recessed Cans for use with the Ascent® LED
IC rated recess can luminaires:
Capri
CR1
QL1
PR1
Elco
EL7IC,
EL7ICA,
EL7IC100A,
EL7RICA
Halo
H7ICT, H7ICAT, H7RICAT,
H7ICTNB, H7ICATNB, H7T,
H7RT, H7TNB, H7UICT,
H7UICAT, H7RICAT,
ET700, ET700R,
EI700, EI700AT, EI700NB,
ET700R, EI700RAT,
EI2072RAT, EI2072AT,
EI700U, I700UAT
Juno
IC22
IC22R
IC2
Lithonia
LC6
Prescolite
Thomas
DBX,
PS1
DBXQC,
RMNICD,
RMNICDAT,
IBXHW
Non-IC rated recess can luminaires:
Capri
QL1
Elco
R10H
RR10H
Juno
TC2
Lithonia
LC6
Prescolite
DBX,
DBXQC,
RMNICD,
RMNICDAT,
IBXHW
2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • www.americanfluorescent.com