J7.1.21 800 TO 9000 LUMEN 8˝ LED RETRO-FIT DOWNLIGHT ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT •One fixture converts nearly any manufacturers incandescent, CFL or H.I.D. fixtures with apertures of 7-⅝˝ to 8-⅛˝ diameter to high PARABOLIC LENSED APERTURE efficiency LED LRT8 SERIES •All installation can be performed from below the ceiling without Type Cat. No. removing existing fixture • Lumen packages comparable to mean lumens for 26W, 32W, 42W, 2x26W, 2x32W CFL and 39W, 70W ED17 CMH with Project: energy savings up to 35% Notes: •Superior-quality white LED light output using Chip on Board technology PASSIVE COOLING DIMENSIONS: 800 - 4000 Lumens •No harmful ultraviolet or infrared wavelengths Optional Medium Base socket adapter for 4-3/4˝ Dia. quick retro-fit of incandescent fixtures •No lead or mercury (see ‘INC’ option below) PRODUCT SPECIFICATIONS Optics 5˝ To Existing junction Box Reflector/Lens: Computer-optimized parabolic reflector with frosted convexed lens recessed into cone provides uniform distribution with no striations • Concealed LED array provides superior aesthetic appeal both on and off Finishes: Low iridescent specular, semi-specular and satin Alzak® finishes available with integral white flange • See reflector options for other colors and finishes Baffle: White or black painted deep multi-groove aluminum baffle insert with integral white painted flange and frosted convexed glass lens 6-1/4˝ Electrical Driver Box 4-1/2˝ Dia. 7-1/2˝ LED Light Engine: Compact light source delivers uniform illumination without pixilation, enabling excellent beam control • Consistent fixture-to-fixture color tem1-5/8˝ perature within 3 SDCM • Replaceable light engine with quick connector mounts directly to heat sink and is easily replaceable• CRI> 80 7˝ Dia. Passive Cooling: Cast aluminum heat sink integrated directly with housing pro9-1/2˝ Dia. vides superior thermal management to ensure the long life of LED Active Cooling: Low noise, high efficiency, long life fan with ultra-low thermal resistance heat sink ensures long life and maximum performance of LEDs on light weight units of 4,500 lumens and higher • Active cooling unit easily accessable ACTIVE COOLING DIMENSIONS: 4500 - 9000 Lumens from above or below the ceiling Optional Medium Base socket adapter for 4-3/4˝ Dia. quick retro-fit of incandescent fixtures LED Driver: Power factor >0.9 • Easily replaceable from above or below the (see ‘INC’ option below) ceiling. Dimming: Dimmable via 0-10V protocol standard • Optional drivers available To Existing junction Box for use with Lutron EcoSystem or 2-wire dimmers • For a list of compatible dimmers, see LED-DIM. Life: Rated for 50,000 hours at 70% lumen maintenance • Available with option al Lumen Depreciation Indicator (LDI) Operation Temperature: -20o C to 50o C Mechanical 5˝ 12˝ Retro-fit Housing: Housing installs from below ceiling • Secured in place by three (3) tension clips • Tension clips accommodate ceilings from 1/2” to 1-1/8″ thick • Integral heat sink conducts heat away from LED light engine • Driver is accessible from below the ceiling and can be upgraded to accommodate future technology improvements. 3-1/2˝ Driver Box 8-1/8˝ Labels and Listings • • • • UL listed for damp locations • UL and cUL, RoHS compliant EMI complies with FCC 47, Part 15, Class A Energy Star qualified, see back page for designated products I.B.E.W. Union made • ARRA compliant Warranty: 5 years when used in accordance with manufacturing guidelines. Product specifications subject to change without notice. Rev.3 08/14 1-3/4˝ 7˝ Dia. 9-1/2˝ Dia. 1300 South Wolf Rd • Des Plaines, Illinois 60018 PHONE 800-367-5866 • FAX 888-708-6578 www.junolightinggroup.com J7.1.21 ORDERING INFORMATION: Rough-in and reflector each ordered separately. LRT8 - 33 35 LRT8 LRT800 B - W G2 LIGHT ENGINE LUMENS 08 800 lm 13 1300 lm 15 1500 lm 17 1700 lm 23 2300 lm 28 2800 lm 33 3300 lm 40 4000 lm 45 4500 lm 50 5000 lm 55 5500 lm 60 6000 lm 65 6500 lm 70 7000 lm 75 7500 lm 80 8000 lm 85 8500 lm 90 9000 lm CCT 27 2700 30 3000 35 3500 404100 VOLTAGE UUniversal OP T ISH - WET LRT800 G2 P Parabolic C Clear W White Fuse and Fuse Holder Chicago Plenum Emergency Battery Pack W/ Remote Test Switch (Cannot be used w/ INC option) Medium base socket adapter for quick retro-fit of incandescent fixtures (120V only) Lutron Driver compatible with 3-wire Fluorescent controls and Lutron Programable Dimming EcoSystem® Forward Phase Dimming Lutron Driver - 120V only (2-wire dimming, neutral wire required) Lumen Depreciation Indicator (Cannot Be Used w/ BR Option) B Baffle W White B Black 1120V 2277V 3347V F CP BR ∗INC PD FDL •LDI FIN CO LO R TR 2 - G2 - LDI IO NS E YL IM ST IO NS OP T GE NE VO LTA G E RA TIO N Reflector: L EN IGH GI T NE LU ME CO NS LO RT EM P. Rough-In: L Specular S Satin Q Semi-Specular Blank for White WET Wet location Listing 800 & 1300 lumen fixtures are universal voltage (120/277V) Available for 4000 Lumens and up. •Not available for 4500 Lumens and up. *INC requires 120V at socket Not available for 347V Not ENGINEERING DATA 347 Volt available, consult factory. Voltage 120V Light Engine Lumens 800 1300150017002300 2800330040004500500055006000 650070007500 8000 8500 9000 CCT (2700K/3000K/3500K/4000K) Input Current 0.0750.1250.1580.1830.242 0.3080.3000.3830.3370.3820.4260.452 0.4920.5520.601 0.638 0.694 0.766 Input Wattage 9W15W19W22W29W 37W36W46W40W46W51W54W 59W66W72W 76W 83W 92W Input Frequency 50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz 50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz 50/60Hz50/60Hz50/60Hz 50/60Hz 50/60Hz 50/60Hz 0.90.90.90.90.9 0.90.90.90.90.90.90.9 0.90.90.9 0.9 0.9 0.9 Power Factor Voltage 277V Light Engine Lumens 800 13001500170023002800330040004500 5000 5500600065007000750080008500 9000 CCT (270K/3000K/3500K/4000K) Input Current 0.0320.0540.0690.0790.1050.1340.1300.1660.146 0.165 0.1850.1960.2130.2390.2600.2760.301 0.332 Input Wattage 9W15W19W22W29W37W36W46W40W 46W 51W54W59W66W72W76W83W 92W Input Frequency 50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz 50/60Hz 50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz 50/60Hz 0.90.90.90.90.90.90.90.90.9 0.9 0.90.90.90.90.90.90.9 0.9 Power Factor Energy Star Qualified: Product # Fixture Configurations = Energy Star (120-277V) Lumen Pacvkage: CCT: Voltage: Reflector Finish: LRT8-(XX)(YY)(Z); LRT800P-C(F) (347V) LRT8-(XX)(YY)3; LRT800P-C(F) XX = 08, 13, 15, 17, 23, 28, 33, 40, 50, 55, 60, 65, 70, 75, 80, 85, 90 YY = 27, 30, 35, 40 Z = 1, 2 F = L, S, Q Lumen Package: XX = 15, 17, 23, 33, 40, 45, 50, 55, 60, 65, 70, 75, 75, 80, 90 CCT: YY = 27, 30, 35, 40 Reflector Finish: F = L, Q 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2014 Juno Lighting, LLC. J7.1.21 Catalog Number: LRT8-90401-G2; LRT800P-CL PHOTOMETRIC REPORT Test Number: PR11132682P Total Lumen Output: 5990 Lumens Luminaire Efficacy: 66.0 lm/w (4K) Luminaire Spacing Criteria: 0.90 Luminaire: Clear specular Alzak® Cone with Frosted Glass Convexed Lens, Enclosed bottom. CIE-Type: Direct 90º 85º 500 1,000 75º 1,500 65º 2,000 2,500 55º 3,000 3,500 4,000 45º 4,500 5,000 5,500 35º 6,000 6,500 7,000 7,500 8,000 8,500 0º 5º 15º 25º Catalog Number: LRT8-40351-G2; LRT800P-CL PHOTOMETRIC REPORT Test Number: PR05131081 Total Lumen Output: 2742 Lumens Luminaire Efficacy: 60.3 lm/w (35K) Luminaire Spacing Criteria: 0.57 Luminaire: Clear specular Alzak® Cone with Frosted Glass Convexed Lens, Enclosed bottom. CIE-Type: Direct 90º 85º 400 75º 800 1200 1600 2000 2400 2800 65º 55º 45º 3200 3600 4000 35º 4400 4800 5200 CCT MULTIPLIER: (3300-4000 Lumens) 5600 6000 0º 25º 5º 15º 27K 3K 35K 4K .87 .96 Baseline 1.02 Catalog Number: LRT8-15401-G2; LRT800P-CL PHOTOMETRIC REPORT Test Number: PR05131071P Total Lumen Output: 1129 Lumens Luminaire Efficacy: 62.4 lm/w (4K) Luminaire Spacing Criteria: 0.57 Luminaire: Clear specular Alzak® Cone with Frosted Glass Convexed Lens, Enclosed bottom. CIE-Type: Direct 90º 85º 200 75º 400 600 800 1000 1200 1400 65º 55º 45º 1600 1800 2000 35º 2200 2400 2600 CCT MULTIPLIER: (800-2800 Lumens) 2800 3000 0º 25º 5º 15º 27K 3K 35K 4K .83 .92 .93 Baseline Initial Footcandles Distance to Illuminated Plane (Feet) Footcandles Footcandles Beam Center Beam Edge Beam Diameter 6’ 7’ 8’ 9’ 10’ 11’ 12’ 13’ 14’ 15’ 175.963.36.4’ 129.346.57.5’ 99.0 35.68.5’ 78.2 28.29.6’ 63.3 22.810.7’ 52.3 18.811.8’ 44.0 15.812.8’ 37.5 13.513.9’ 32.3 11.615.0’ 28.1 10.116.0’ Luminance Data Candlepower Distribution (Candelas) Angle Candela/M2 Angle Candela Lumens in Degrees 45°28,576 0° 6333 5° 6373 1807 55°922 15° 4015 1858 65°191 25° 2028 1274 75°524 35° 538 417 85°0 45° 14 13 Zonal Lumen Summary 55° 2 2 Zone Lumens %Fixture 65° 0 0 0-30° 4279 71.5 75° 0 0 0-40° 5553 92.7 85° 0 0 0-60° 5982 99.9 0-90° 5988 100.0 90-180° 0 0.0 0-180° 5988 100.0 Initial Footcandles Distance to Illuminated Plane (Feet) Footcandles Footcandles Beam Center Beam Edge Beam Diameter 6’ 7’ 8’ 9’ 10’ 11’ 12’ 13’ 14’ 15’ 134.458.23.8’ 98.8 42.84.4’ 75.6 32.75.1’ 59.7 25.95.7’ 48.4 21.06.3’ 40.0 17.37.0’ 33.6 14.67.6’ 28.6 12.48.3’ 24.7 10.78.9’ 21.5 9.39.5’ Luminance Data Candlepower Distribution (Candelas) Angle Candela/M2 Angle Candela Lumens in Degrees 45°9188 0° 4839 55°151 5° 4486 428 15° 2801 794 65°515 25° 1827 849 75°425 35° 857 539 85°0 45° 161 125 Zonal Lumen Summary 55° 2 2 Zone Lumens %Fixture 65° 0 0 0-30° 2068 75.4 75° 0 0 0-40° 2606 95.1 85° 0 0 0-60° 2733 99.7 0-90° 2742 100.0 90-180° 0 0.0 0-180° 2742 100.0 Initial Footcandles Distance to Illuminated Plane (Feet) 6’ 7’ 8’ 9’ 10’ 11’ 12’ 13’ 14’ 15’ Footcandles Footcandles Beam Center Beam Edge Beam Diameter 55.4 24.03.8’ 40.7 17.64.4’ 31.2 13.55.1’ 24.6 10.75.7’ 20.0 8.66.3’ 16.5 7.17.0’ 13.9 6.07.6’ 11.8 5.18.3’ 10.2 4.48.9’ 8.9 3.89.5’ Luminance Data Candlepower Distribution (Candelas) Angle Candela/M2 Angle Candela Lumens in Degrees 45°3789 0° 1996 55°0 5° 1850 177 15° 1155 327 65°0 25° 754 349 75°213 35° 354 222 85°0 45° 67 52 Zonal Lumen Summary 55° 0 0 Zone Lumens %Fixture 65° 0 0 0-30° 853 75.6 75° 0 0 0-40° 1075 95.2 85° 0 0 0-60° 1127 99.8 0-90° 1129 100.0 90-180° 0 0.0 0-180° 1129 100.0 AVERAGE INITIAL FOOTCANDLES Reflectances: 80% Ceiling, 50% Walls, 20% Floors Luminaire Spacing 5’ x 5’ 6’ x 6’ 7’ x 7’ 8’ x 8’ 9’ x 9’ 10’ x 10’ 11’ x 11’ 12’ x 12’ RCR1 266 185 136 104 82 66 55 46 Room Cavity Ratio RCR4 216 150 110 84 67 54 45 37 RCR8 168 116 86 66 52 42 35 29 COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method) Effective Floor Reflectance 20% PCC 80 70 50 30 10 0 PW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 120120120 120 117117117117 112112 112 107107107 102102102 100 1 114111109 107 112109107105 105103 102 101100 99 98 97 96 94 2108104 100 96 10610298 95 99 96 93 9693 91 939189 87 31039792 88 1019591 87 93 89 86 9087 84 888583 81 49890 85 80 96898480 8783 79 858178 838077 76 59384 79 74 91837874 8277 73 807673 787572 71 68879 73 69 87787369 7772 68 757168 747067 66 78474 68 64 82746864 7267 64 716763 706663 62 88070 64 60 78696460 6863 60 676359 666259 58 97666 60 56 75666056 6560 56 645956 635956 54 107263 57 53 71625653 6156 53 605652 605552 51 AVERAGE INITIAL FOOTCANDLES Reflectances: 80% Ceiling, 50% Walls, 20% Floors Luminaire Spacing 5’ x 5’ 6’ x 6’ 7’ x 7’ 8’ x 8’ 9’ x 9’ 10’ x 10’ 11’ x 11’ 12’ x 12’ RCR1 122 85 62 48 38 30 25 21 Room Cavity Ratio RCR4 101 70 51 39 31 25 21 18 RCR8 80 56 41 31 25 20 17 14 COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method) Effective Floor Reflectance 20% PCC 80 70 50 30 10 0 PW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119119119 119 117117117117 111111 111 107107107 102102102 100 1 114111109 107 112109107105 105104 102 102100 99 98 97 96 94 2109104 100 97 10710299 96 99 96 94 9694 92 939290 88 31049793 89 1029692 88 94 90 87 9188 85 898684 83 49991 86 82 97908582 8884 81 868380 848179 77 59486 80 76 92858076 8379 75 827875 807774 73 69081 75 71 88807571 7974 71 777370 767270 63 78577 71 67 84767067 7570 66 736966 726866 64 88272 67 63 80726663 7166 62 706562 696562 61 97869 63 59 77686359 6762 59 666259 666259 57 107565 60 56 74656056 6459 56 635956 635855 54 AVERAGE INITIAL FOOTCANDLES Reflectances: 80% Ceiling, 50% Walls, 20% Floors Luminaire Spacing 5’ x 5’ 6’ x 6’ 7’ x 7’ 8’ x 8’ 9’ x 9’ 10’ x 10’ 11’ x 11’ 12’ x 12’ RCR1 50 35 26 20 15 13 10 9 Room Cavity Ratio RCR4 42 29 21 16 13 10 9 7 RCR8 33 23 17 13 10 8 7 6 COEFFICIENTS OF UTILIZATION - % (Zonal Cavity Method) Effective Floor Reflectance 20% PCC 80 70 50 30 10 0 PW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 120120120 120 117117117117 112112 112 107107107 102102102 100 1 114112109 107 112109107105 105104 102 102100 99 98 97 96 94 2109104 100 97 10710399 96 99 96 94 9694 92 949290 88 31049893 89 1029692 88 94 90 87 9188 86 898684 83 49992 86 82 97908682 8884 81 868380 858179 78 59486 81 76 93858076 8379 75 827875 807774 73 69081 75 71 88807571 7974 71 787370 767370 68 78677 71 67 84767167 7570 66 746966 726966 64 88273 67 63 80726763 7166 63 706562 696562 61 97869 63 59 77686359 6762 59 676259 666259 57 107565 60 56 74656056 6459 56 635956 635956 54 Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field. 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2014 Juno Lighting, LLC.