Specification Sheet

advertisement
13" APERTURE
16.25
412.7 mm
Lamp Options:
13QPL - 13W Biax (G24q1)
18PLT - 18W Quad Fluorescent (G24q2)
26PLT - 26W Triple Tube Fluorescent (G24qx)
32PLT - 32W Triple Tube Fluorescent (G24qx)
42PLT - 42W Triple Tube Fluorescent (G24qx)
Splay Option:
WB - White Micro Baffle
MB - Black Micro Baffle
BRB - Bronze Micro Baffle
PW - Painted White Splay
PB - Painted Black Splay
PBR - Painted Bronze Splay
Lens Option:
P12 - Prismatic Acrylic (standard)
FF - Glass Fresnel Lens
C73 - Corning Pattern 73
Installation Options:
C - C Channel Hangers 27" (2)
BH - T-Bar Ceiling Hanging Assemblies (2)
TP - Tamper Proof
Electrical Options:
EM - Emergency Battery Pack
DIMH - Dimming Ballast - 3 Wire Lutron
HiLume
DIMG - Dimming Ballast - 2 Wire generic
277 - 277 Volt Operation
GLR - In Line Fusing
12.675
321.9mm
2.0
13.0
333.2 mm
14.0
355.6 mm
PRODUCT SPECIFICATION DATA:
Low iridescent specular Alzak® reflector.
Designed for 1 vertically mounted QPL or PLT lamps.
Lamps by others.
White splay insert (secured with torsion springs) holds lens
(prismatic pattern #12 standard).
Capable of mounting in 2” thick ceiling.
Positive trim retention.
14 Gauge galvanized junction box with snap-on
covers.
Suitable for through wiring (4in/4out) #12 AWG.
Factory wired for ease in installation.
UL/CUL Listed / Damp Location.
Chicago Plenum-CCEA - consult factory.
Electronic Ballast standard.
Ballast accessible from below ceiling.
To assure optimum quality and performance in our product, PMC lighting is
requiring the use of Osram Sylvania, Ushio,
or Phillips brand lamps in out fixtures. Older square base
lamps will not fit and may cause damage.
ORDERING INFORMATION
17.5
444.5 mm
FLV- 13SPL-18PLT - PW- P12- 120LIGHT SOURCE APERTURE
FLUORESCENT
VERTICAL
SPLAY OPTIONS
LAMP
13QPL
18PLT
26PLT
32PLT
42PLT
PW
PB
PBR
MB
WB
BRB
LENS
P12
FF
C73
VOLTAGE OPTIONS
120
277
EM
DIMH
DIMG
GLR
2CIR
C
BH
TP
a division of PMC Lighting Inc
100 Gilbane Street / Warwick, RI 02886 • 401.738.4963 FAX.401.738.0618
www.oceanstatelighting.com
FL-21
RECESSED FLUORESCENT
OPTIONS:
VERTICAL LAMPS
RECESSED COMPACT FLUORESCENT
LENS LIGHT / SPLAY
RECESSED FLUORESCENT
13" APERTURE
VERTICAL LAMPS
RECESSED COMPACT FLUORESCENT
LENS LIGHT / SPLAY
PHOTOMETRICS
Model No. FLV-13SPL-32PLT-PW-C73120-EB
CANDELLA
VERT° AT 0°
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
3
13
22
47
71
109
146
224
302
437
572
706
839
948
1057
1121
1185
1174
Coefficients of Utilization-Zonal Cavity
FOOTLAMBERTS
90°-85°
117
80°-75°
290
70°-65°
573
60°-55°
868
50°-45°
1456
Efficiency:
67.6%
S/MH Ratio:
0.981
VERT° AT 0°
0
9
20
30
47
64
87
110
166
222
347
471
679
887
1019
1151
1191
1230
1194
80%
RCR 70 50
1
.76 .74
2
.71 .68
3
.67 .62
4
.63 .57
5
.59 .52
6
.55 .48
7
.52 .44
8
.48 .41
9
.45 .37
10 .42 .34
30
.72
.64
.58
.52
.47
.43
.39
.36
.32
.30
70%
70 50
.74 .72
.70 .66
.66 .61
.61 .56
.57 .51
.54 .47
.51 .44
.47 .40
.44 .37
..41 .34
30
.71
.63
.57
.52
.47
.43
.39
.36
.32
.29
50%
50 30
.70 .68
.64 .62
.59 .56
.54 .51
.50 .46
.46 .42
.43 .39
.39 .35
.36 .32
.33 .29
DISTANCE FROM
LIGHT SOURCE
10
.67
.60
.54
.48
.43
.39
.36
.32
.29
.26
Coefficients of Utilization-Zonal Cavity
FOOTLAMBERTS
90°-85°
352
80°-75°
395
70°-65°
516
60°-55°
654
50°-45°
1070
Efficiency: 63.6%
S/MH Ratio:
0.995
80%
RCR 70 50
1
.72 .69
2
.67 .64
3
.63 .59
4
.60 .54
5
.56 .50
6
.53 .46
7
.50 .43
8
.47 .40
9
.44 .37
10 .41 .34
30
.68
.61
.55
.50
.46
.42
.39
.35
.32
.30
70%
70 50
.70 .68
.66 .63
.62 .58
.58 .53
.55 .49
.52 .46
.49 .42
.46 .39
.43 .36
.40 .34
30
.66
.60
.54
.50
.45
.42
.38
.35
.32
.30
50%
50 30
.66 .64
.60 .58
.56 .53
.52 .49
.48 .44
.45 .41
.42 .38
.39 .35
.36 .32
.33 .29
BEAM
DIAMETER
8'
19.0
5.9'
10'
12.2
7.4'
12'
8.4
8.9'
14'
6.2
10.4'
16'
4.4
11.9'
18'
3.8
13.3'
CONE OF LIGHT
Model No. FLV-13SPL-32PLT-PW-FF-120EB
CANDELLA
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
CONE OF LIGHT
INITIAL NADIR FOOTCANDLES
INITIAL NADIR FOOTCANDLES
DISTANCE FROM
LIGHT SOURCE
10
.63
.56
.51
.46
.42
.38
.35
.32
.29
.27
BEAM
DIAMETER
8'
18.7
5.9'
10'
12.0
7.4'
12'
8.1
8.9'
14'
5.9
10.4'
16'
4.1
11.9'
18'
3.5
13.3'
Lumen Correction Factors
1 to 1 ratio
13 watt - 900 Lumens
18 watt - 1250 Lumens
26 watt - 1800 Lumens
32 watt - 2400 Lumens
42 watt - 3200 Lumens
INSTALLATION
Universal mounting brackets are installed on all
fixtures. C-Channels (shown) are the preferred
system for mounting in Plaster-type ceilings.
For T-Bar ceilings and other mounting use BH
Hangers or scrap EMT.
Ocean State Lighting has designed this system
for sloped ceilings specifically to make installation as easy and rapid as possible. For details
consult the factory.
a division of PMC Lighting Inc
100 Gilbane Street / Warwick, RI 02886 • 401.738.4963 FAX.401.738.0618
www.oceanstatelighting.com
Download