Table C2.1: Light Intensity Required for Various Activities (Foot Candles). Purpose F-c Purpose Storage, halls 5 Bedrooms, stairs, dining room 8 Very rough work: 10 kitchen, laundry, sewing, 100 workshop and playroom 15 Rough work or play 20 Close work: reading, study, sewing, shaving, drawing 30 Careful work: fine reading drafting dark sewing F-c 50 60 80 80 Fine and exact work Extra-fine work 300 40 General illumination will usually require about 3 watts of electric lighting per square foot of floor area, but this is subject to broad variation as indicated above. Section Break (Next Page) Table C2.2: Lighting Requirement For Farm Buildings Location Lighting Unit* Installation BEEF BARN 100 watt One unit per 500 square feet of floor area. DAIRY Milkhouse 100 watt Two units to illuminate interior of bulk tank, not to be located directly over tank. 100 watt One unit over wash area. 100 watt One unit outside to illuminate area for milk ceiling. 100 watt One unit per stall directed at the udder. This may be a shielded light from below or from the ceiling. Pen Barn 100 watt One unit per 250 square feet of floor area. Stall barn 100 watt Mount on ceiling 20-feet apart; over feed alleys, 12 feet apart; over litter alleys. HOG FARROWING HOUSE 100 watt One unit per pair of pens or stalls. Locate over partition. HOG FINISHING HOUSE 100 watt One unit per 400 square feet of floor area. POULTRY Brooder house 15 watt One unit per 200 square feet of floor area. 40 watt or 60 watt One unit per 200 square feet of floor area. 100 watt One unit per 20 feet of feed alley and one for every 250 square feet of pen area Milking room Laying house SHEEP BARN Table C2.2: Lighting Requirement For Farm Buildings (Continued) Location Lighting Unit* FARM SHOP General lighting 150 watt Local lighting 150 watt or two 40 watt fluorescent Installation One unit per 200 square feet of floor space. One unit per 10 feet of work bench at 4 to 5 feet above the bench. GARAGE 100 watt One unit per 250 square feet. Provide convenient outlets for portable light. MACHINE STORAGE 100 watt One unit per 300 square feet of floor area. FEED ROOMS Storage room. 100 watt One unit per 400 square feet of floor dust-proof area. Switch outside feed reflector Preparation room. 100 watt One unit per 150 square feet of floor dust-proof area. Switch outside feed reflector HAYLOFT 200 watt dust-proof reflector Locate for general lighting, easy servicing, and near or over hay chute. Switch at foot of ladder. YARD LIGHT 300 watt or PAR 38 Locate over top of pole 15 to 20 feet above the ground and where most convenient. Use multiple switching, or a light sensitive element for automatic switching. *Incandescent with reflector unless otherwise indicated.