Current Limiting Solutions

advertisement
Current Limiting Solutions
Innovative current limiting solutions for optimal trac
lighting performance in an energy conscious world
Current Limiting Solutions
Table of Contents
Code Compliance.......................................................2
Energy Code Calculations..........................................3
Current Limiting Subpanels...................................4-5
Current Limiting Feeds..........................................6-9
Trac-Master...........................................................7
Trac-Lites...............................................................7
Pendant Stem Kits................................................8
HD Commercial Trac.............................................9
Current Limiting Circuit Breakers........................9
Energy Codes............................................................10
Juno Lighting Group | Current Limiting Solutions
Frustrated by your local energy codes?
Are stringent energy codes impacting the way you highlight, promote and sell your merchandise? With energy
codes throughout North America establishing power limits for commercial and retail lighting environments, the
ability to apply trac lighting effectively is becoming increasingly difficult. Expressed in watts-per-square-foot,
these codes mandate total power consumption of installed lighting fixtures for a given space. Because of its
inherent flexibility, line-voltage trac lighting is typically assigned an arbitrary multiplier for purposes of energy
calculations. Depending on the specific code, these multipliers can range from 30 to 70 watts per foot of trac,
regardless of the actual power consumed by the specified fixtures. Therefore, even though a trac lighting
installation may employ energy efficient fixtures, the watts-per-linear-foot power consumption formula still
applies, effectively penalizing an otherwise energy-conscious design.
Fortunately, there is a simple solution to this dilemma. By specifying a Juno current limiting solution with
your trac lighting, energy codes permit the current limiter rating to be substituted for the linear footage
formula. This means that trac installations can be designed using ultra-efficient fixtures, and effortlessly
achieve code compliance.
The Solutions
Juno Lighting Group can help you meet the challenge of energy code compliance with
either a Current Limiting Subpanel or Current Limiting Trac Feeds. The Subpanel solution
installs between the branch circuit breaker and the trac lighting equipment and provides
the lowest installed-cost solution. The Current Limiting Trac Feeds are intended to be
installed at every trac feed location in place of a standard non-limiting feed, making it
perfect for either new construction or upgrading existing circuits in a remodel or retrofit
application. By incorporating either current limiting solution into company-wide trac
lighting specifications, multi-facility organizations can be assured of lighting code
compliance regardless of location. And no matter which system is best suited to a given
application — subpanel or trac feed — Juno is your one-stop supplier for both solutions.
How the Devices Work
Both systems utilize supplementary current limiting circuit breakers, designed to limit
available wattage based on the actual lighting design criteria, thereby avoiding the
“watts-per-linear-foot penalty” imposed by energy codes. Trac lighting density and
performance can be optimized, and configuration flexibility can be retained, without
exceeding code-mandated power utilization limits.
Optimize Your Energy Usage
To optimize your energy usage and to maximize operating cost savings, combining energy
efficient LED, high-performance ceramic metal halide (CMH) and economical compact
fluorescent trac fixtures with either current limiting solution can reduce calculated energy
use by as much as 75% or more versus standard halogen fixtures. This enables you to
provide the lighting you need to effectively highlight merchandise and increase sales.
Juno Lighting Group | Current Limiting Solutions
1
Current Limiting Solutions
Code Compliance
Case Study
Background
A leading specialty retailer with more than 1,000
locations nationwide planned to renovate each location.
The rebranding efforts of the retail store locations
included extensive trac lighting, providing the retailer
with the flexibility to move, replace and redesign
merchandising displays.
With their rebranding efforts, the retailer recognized
that greater efficiencies could be realized, not only in
energy, but in overall maintenance costs by using
Juno’s energy efficient, high performance LED trac
fixtures. But this energy savings wasn’t enough when
the new energy codes were enforced.
Challenge
With new energy codes throughout North America placing
a mandatory limit on lighting density, trac lighting had an
additional burden: an automatic VA (wattage) calculation
per linear foot of trac. ASHRAE 90.1, the basis for many
municipal energy codes around the country, assigns
30-watts per linear foot of trac. California’s Title 24 code
assigns 45-watts and other more stringent codes may
assign up to 70-watts per linear foot.
Using California Title 24’s 45-watts per linear foot
calculation, the retailer’s lighting layout had the calculated
potential of using over 35,000 watts in a single store
according to the energy code. This was an enormous
exaggeration above the actual planned wattage of 7000
watts per store and 8.75-watts per linear foot of trac.
With stores projected to open in just a few weeks,
redesigning the stores again and eliminating a large
portion of trac lighting was not an option.
Solution
To solve this problem, the retailer called on
the expertise of their local Juno Lighting
Group National Account Sales Manager.
Working around the clock to meet a nearly
impossible build schedule, and working
closely with the California Energy
Commission to obtain early acceptance and
to avoid delaying any store openings, the
solution was a sub-branch current limiting
panel. This panel would limit the amount of
wattage used on each trac, consequently
eliminating the penalty for the calculated
potential maximum load/unused wattage.
The Juno Current Limiting Subpanel
reduced the retailer’s calculated potential/
unused wattage by over 75%. In fact, the
retailer selected their current limiters to total
8000 watts, leaving them with additional
flexibility for expansion while still easily
complying with the local energy codes.
Juno. Solutions.
2
Juno Lighting Group | Current Limiting Solutions
Energy Code Calculations
Illustrated below is an example of what current limiting means
for trac lighting relative to today’s energy codes. The standard
layout without a current limiting solution consists of 100’ of single
circuit trac (4 circuits x 25’ each) with 32 LED trac fixtures, each
consuming 24W maximum, for a total connected load of 768W.
Per the Title 24 energy code, the wattage calculation would be
a much greater 4500W.
The scenario with the Trac-Master Current Limiting Subpanel uses the original 100’ of
single circuit trac, broken down into four 25’ runs, with each monitored by a 2-Amp
current limiting supplementary protector that is closely matched to the actual
connected load plus a small buffer. This results in the minimum calculated watts per
the energy codes, making the wattage calculation independent of trac length.
In a real application, there would be many more trac lighting circuits, resulting in
an even greater calculated wattage reduction.
Calculations Example
Without Current Limiting
Track length determines wattage calculation
Actual Connected Load = 24W x 32 Fixtures = 768W
100 ft of trac = 4500W*
*Based on 45W/ft multiplier of California Title 24
With Current Limiting
2A, 240W
2A, 240W
2A, 240W
Branch Circuit
Breaker Panel
2A, 240W
Trac-Master
Current Limiting
Control Panel
Actual Connected Load = 24W x 32 Fixtures = 768W
Same 100 ft of trac: 2A@120V = 240W x 4 circuits = 960W total
Juno Lighting Group | Current Limiting Solutions
3
Current Limiting Solutions
Current Limiting Subpanels
The Juno Current Limiting Subpanel
permits you to take full advantage of
any line voltage trac lighting without
being penalized by watts-per-linear-foot
energy code calculations. The subpanel
is typically installed out-of-sight in an
electrical control room, providing a
centralized location for installation wiring
and breaker access in the event of a
circuit overload. The Current Limiting
Subpanel installs between the branch
circuit breaker and the trac lighting
equipment. This limits the amount of
power that is available to operate the
trac circuit to only the wattage needed
per the lighting plan. Installation labor
is minimized since multiple trac runs
can be fed from a single current limiting
circuit breaker.
The subpanel is offered in any
configuration from 1 thru 42 circuits
and is available in either surface or
flush mount versions. Current limiting
is provided by supplementary current
limiting breakers that are selected
at the time of order based on the
actual lighting loads specified.
Breakers are rated 120/277V and are
available in 0.5A, 1A, 2A, 3A, 4A, 5A,
6A, 7A, 8A, 10A, 13A and 15A current
ratings. Note that Juno recommends
that breakers be loaded to maximum
of 80% of rating to avoid nuisance
tripping. All Current Limiting
Subpanels are factory pre-assembled
and customized for your specific
application . . . no programming is
required. Complimentary factory
assistance is available to guide you
through the simple specification process.
4
Juno Lighting Group | Current Limiting Solutions
Current Limiting Subpanels
Ordering Information and Dimensions
Surface Mount
Cat. No.
Description
Surface Mount, 1 Circuit
Surface Mount, 2 Circuit
Surface Mount, 3 Circuit
Surface Mount, 4 Circuit
Surface Mount, 5 Circuit
Surface Mount, 6 Circuit
Surface Mount, 7 Circuit
Surface Mount, 8 Circuit
Surface Mount, 9 Circuit
Surface Mount, 10 Circuit
Surface Mount, 11 Circuit
Surface Mount, 12 Circuit
CLS1M
CLS2M
CLS3M
CLS4M
CLS5M
CLS6M
CLS7M
CLS8M
CLS9M
CLS10M
CLS11M
CLS12M
Cat. No.
Description
Surface Mount, 6 Circuit
Surface Mount, 7 Circuit
Surface Mount, 8 Circuit
Surface Mount, 9 Circuit
Surface Mount, 10 Circuit
Surface Mount, 11 Circuit
Surface Mount, 12 Circuit
Surface Mount, 13 Circuit
Surface Mount, 14 Circuit
Surface Mount, 15 Circuit
Surface Mount, 16 Circuit
Surface Mount, 17 Circuit
Surface Mount, 18 Circuit
Surface Mount, 19 Circuit
Surface Mount, 20 Circuit
Surface Mount, 21 Circuit
CLS6
CLS7
CLS8
CLS9
CLS10
CLS11
CLS12
CLS13
CLS14
CLS15
CLS16
CLS17
CLS18
CLS19
CLS20
CLS21
4-12 Circuit Panel
9 1/16"
12 3/4"
3 15/16"
Flush Mount
6-21 Circuit Panel
14 1/4"
17 7/8"
3 13/16"
Cat. No.
Description
Surface Mount, 22 Circuit
Surface Mount, 23 Circuit
Surface Mount, 24 Circuit
Surface Mount, 25 Circuit
Surface Mount, 26 Circuit
Surface Mount, 27 Circuit
Surface Mount, 28 Circuit
Surface Mount, 29 Circuit 33 13/16"
Surface Mount, 30 Circuit
Surface Mount, 31 Circuit
Surface Mount, 32 Circuit
Surface Mount, 33 Circuit
Surface Mount, 34 Circuit
Surface Mount, 35 Circuit
Surface Mount, 36 Circuit
Surface Mount, 37 Circuit
Surface Mount, 38 Circuit
Surface Mount, 39 Circuit
3 13/16"
Surface Mount, 40 Circuit
Surface Mount, 41 Circuit
Surface Mount, 42 Circuit
CLS22
CLS23
CLS24
CLS25
CLS26
CLS27
CLS28
CLS29
CLS30
CLS31
CLS32
CLS33
CLS34
CLS35
CLS36
CLS37
CLS38
CLS39
CLS40
CLS41
CLS42
Facilitates compliance with
Title 24 2013,
ASHRAE 90.1
and other energy codes
22-42 Circuit Panel
14 1/2"
Cat. No.
Description
15 7/16"
CLS6F 14 Flush
1/4" Mount, 6 Circuit
CLS7F
Flush Mount, 7 Circuit
CLS8F
Flush Mount, 8 Circuit
CLS9F
Flush Mount, 9 Circuit
CLS10F 19 1/8"
Flush Mount, 10 Circuit
17
7/8"
CLS11F Flush Mount, 11 Circuit
CLS12F Flush Mount, 12 Circuit
CLS13F Flush Mount, 13 Circuit
CLS14F Flush Mount, 14 Circuit
CLS15F Flush Mount, 15 Circuit
CLS16F Flush Mount, 16 Circuit
3 13/16"
3 13/16"
CLS17F Flush Mount, 17 Circuit
CLS18F Flush Mount, 18 Circuit
CLS19F Flush Mount, 19 Circuit
CLS20F Flush Mount, 20 Circuit
CLS21F Flush Mount, 21 Circuit
Cat. No.
6-21 Circuit Panel
15 7/16"
19 1/8"
3 13/16"
Description
15 7/16"
CLS22F14 1/2"
Flush Mount,
22 Circuit
CLS23F Flush Mount, 23 Circuit
CLS24F Flush Mount, 24 Circuit
CLS25F Flush Mount, 25 Circuit
CLS26F Flush Mount, 26 Circuit
CLS27F Flush Mount, 27 Circuit
CLS28F Flush Mount, 28 Circuit
CLS29F 35 Flush
1/8" Mount, 29 Circuit
33 13/16"
CLS30F Flush Mount, 30 Circuit
CLS31F Flush Mount, 31 Circuit
CLS32F Flush Mount, 32 Circuit
CLS33F Flush Mount, 33 Circuit
CLS34F Flush Mount, 34 Circuit
CLS35F Flush Mount, 35 Circuit
CLS36F Flush Mount, 36 Circuit
CLS37F Flush Mount, 37 Circuit
CLS38F Flush Mount, 38 Circuit
CLS39F 3 13/16"
Flush Mount, 39 Circuit
3 13/16"
CLS40F Flush Mount, 40 Circuit
CLS41F Flush Mount, 41 Circuit
CLS42F Flush Mount, 42 Circuit
22-42 Circuit Panel
15 7/16"
35 1/8"
3 13/16"
NOTE: Individual current limiting circuit breaker ratings are determined by the electrical layout drawings. A submittal package will be
provided by Juno Lighting Group for customer approval following receipt of order. Current limiting circuit breaker ratings and panel position
must be provided at the time of order but are not required to be specified as part of the catalog number.
Juno Lighting Group | Current Limiting Solutions
5
Current Limiting Solutions
Current Limiting Feeds
Juno Current Limiting Feeds are the
perfect solution for new construction or
for bringing existing Juno line voltage
trac lighting applications into conformance
with today’s stringent energy codes.
They enable you to take full advantage
of energy efficient, high-performance
LED, ceramic metal halide and fluorescent
trac fixtures without being penalized by
watts-per-linear-foot code calculations,
reducing calculated watts by as much as
75% or more.
Current Limiting Feeds are designed to
take the place of standard non-limiting
feeds and are installed at every trac feed
location. The feeds are compact and mount
close to the ceiling for an unobtrusive
appearance. Available in both end feed
and in-line feed configurations, the Current
Limiting Feeds can be specified for either
Trac-Master 1-circuit, Trac-Master 2-circuit,
HD Commercial 2-circuit or Trac-Lites
1-circuit trac systems. In-line feeds and
2-circuit end feeds are designed to accept
up to two current limiting circuit breakers
simultaneously. Feeds are supplied
with tamper-resistant cover screws and
screwdriver bits making installation
convenient and future tampering impractical.
Current limiting circuit breakers (ordered
separately) are available in increments from
0.25A to 15A, enabling selection that closely
matches the planned wattage use. Colorcoded ON/OFF indication clearly identifies
their status and they are easily resettable
in the event of an overload situation.
6
Juno Lighting Group | Current Limiting Solutions
Current Limiting Feeds Ordering Information and Dimensions
Trac-Master
Mini End Feeds
Cat. No.
Description
Trac Type
Finish
TCLFM11BL
Mini End Feed
1-Circuit
Black
TCLFM11SL
Mini End Feed
1-Circuit
Silver
TCLFM11WH
Mini End Feed
1-Circuit
White
Cat. No.
Description
Trac Type
Finish
TCLF11BL
End Feed
1-Circuit
Black
TCLF11SL
End Feed
1-Circuit
Silver
TCLF11WH
End Feed
1-Circuit
White
TUCLF11BL
End Feed
2-Circuit
Black
TUCLF11SL
End Feed
2-Circuit
Silver
TUCLF11WH
End Feed
2-Circuit
White
End Feeds
In-Line Feeds
Cat. No.
Description
Trac Type
Finish
TCLF21BL
In-Line Feed
1-Circuit
Black
TCLF21SL
In-Line Feed
1-Circuit
Silver
TCLF21WH
In-Line Feed
1-Circuit
White
TUCLF21BL
In-Line Feed
2-Circuit
Black
TUCLF21SL
In-Line Feed
2-Circuit
Silver
TUCLF21WH
In-Line Feed
2-Circuit
White
Cat. No.
Description
Trac Type
Finish
RCLFM11BL
Mini End Feed
1-Circuit
Black
Dimensions
5 3/4"
1 7/8"
1 1/4"
Dimensions
5 7/8"
1 1/4"
4 5/8"
5 3/16"
Dimensions
7 1/8"
1 1/4"
4 5/8"
5 3/16"
Trac-Lites
Mini End Feeds
RCLFM11BZ
Mini End Feed
1-Circuit
Bronze
RCLFM11SL
Mini End Feed
1-Circuit
Silver
RCLFM11WH
Mini End Feed
1-Circuit
White
Cat. No.
Description
Trac Type
Finish
RCLF11BL
End Feed
1-Circuit
Black
RCLF11BZ
End Feed
1-Circuit
Bronze
RCLF11SL
End Feed
1-Circuit
Silver
RCLF11WH
End Feed
1-Circuit
White
Cat. No.
Description
Trac Type
Finish
RCLF21BL
In-Line Feed
1-Circuit
Black
RCLF21BZ
In-Line Feed
1-Circuit
Bronze
RCLF21SL
In-Line Feed
1-Circuit
Silver
RCLF21WH
In-Line Feed
1-Circuit
White
End Feeds
In-Line Feeds
Dimensions
5 1/2"
1 7/8"
1 1/16"
Dimensions
5 7/8"
1 1/4"
4 5/8"
5 3/16"
Dimensions
7 1/8"
1 1/4"
4 5/8"
5 3/16"
Juno Lighting Group | Current Limiting Solutions
7
Current Limiting Solutions
Current Limiting Feeds Ordering Information and Dimensions
Pendant Stem Kits (For Trac-Master or Trac-Lites)
T-Bar Ceiling Mount
Cat. No.
Description
Finish
T90CLF-12-BL
T-Bar Ceiling Kit, 12”
Black
T90CLF-12-BZ
T-Bar Ceiling Kit, 12”
Bronze
T90CLF-12-SL
T-Bar Ceiling Kit, 12”
Silver
T90CLF-12-WH
T-Bar Ceiling Kit, 12”
White
T90CLF-18-BL
T-Bar Ceiling Kit, 18”
Black
T90CLF-18-BZ
T-Bar Ceiling Kit, 18”
Bronze
T90CLF-18-SL
T-Bar Ceiling Kit, 18”
Silver
T90CLF-18-WH
T-Bar Ceiling Kit, 18”
White
T90CLF-24-BL
T-Bar Ceiling Kit, 24”
Black
T90CLF-24-BZ
T-Bar Ceiling Kit, 24”
Bronze
T90CLF-24-SL
T-Bar Ceiling Kit, 24”
Silver
T90CLF-24-WH
T-Bar Ceiling Kit, 24”
White
T90CLF-36-BL
T-Bar Ceiling Kit, 36”
Black
T90CLF-36-BZ
T-Bar Ceiling Kit, 36”
Bronze
T90CLF-36-SL
T-Bar Ceiling Kit, 36”
Silver
T90CLF-36-WH
T-Bar Ceiling Kit, 36”
White
T90CLF-48-BL
T-Bar Ceiling Kit, 48”
Black
T90CLF-48-BZ
T-Bar Ceiling Kit, 48”
Bronze
T90CLF-48-SL
T-Bar Ceiling Kit, 48”
Silver
T90CLF-48-WH
T-Bar Ceiling Kit, 48”
White
Cat. No.
Description
Finish
Rigid Ceiling Mount
T91CLF-12-BL
Rigid Ceiling Kit, 12”
Black
T91CLF-12-BZ
Rigid Ceiling Kit, 12”
Bronze
T91CLF-12-SL
Rigid Ceiling Kit, 12”
Silver
T91CLF-12-WH
Rigid Ceiling Kit, 12”
White
T91CLF-18-BL
Rigid Ceiling Kit, 18”
Black
T91CLF-18-BZ
Rigid Ceiling Kit, 18”
Bronze
T91CLF-18-SL
Rigid Ceiling Kit, 18”
Silver
T91CLF-18-WH
Rigid Ceiling Kit, 18”
White
T91CLF-24-BL
Rigid Ceiling Kit, 24”
Black
T91CLF-24-BZ
Rigid Ceiling Kit, 24”
Bronze
T91CLF-24-SL
Rigid Ceiling Kit, 24”
Silver
T91CLF-24-WH
Rigid Ceiling Kit, 24”
White
T91CLF-36-BL
Rigid Ceiling Kit, 36”
Black
T91CLF-36-BZ
Rigid Ceiling Kit, 36”
Bronze
T91CLF-36-SL
Rigid Ceiling Kit, 36”
Silver
T91CLF-36-WH
Rigid Ceiling Kit, 36”
White
T91CLF-48-BL
Rigid Ceiling Kit, 48”
Black
T91CLF-48-BZ
Rigid Ceiling Kit, 48”
Bronze
T91CLF-48-SL
Rigid Ceiling Kit, 48”
Silver
T91CLF-48-WH
Rigid Ceiling Kit, 48”
White
8
Juno Lighting Group | Current Limiting Solutions
Dimensions
6 3/16"
2 1/16"
12" to 48"
Nominal
Stem Length
1"
10 1/8"
Dimensions
6 3/16"
2 1/16"
12" to 48"
Nominal
Stem Length
1"
10 1/8"
Current Limiting Feeds Ordering Information and Dimensions
HD Commercial Trac
End Feeds
Cat. No.
Description
Finish
TEK11CL-BL
End Feed, Left Polarity 120V
Black
TEK11CL-WH
End Feed, Left Polarity 120V
White
TEK12CL-BL
End Feed, Right Polarity 120V
Black
TEK12CL-WH
End Feed, Right Polarity 120V
White
HTEK11CL-BL
End Feed, Left Polarity 277V
Black
HTEK11CL-WH
End Feed, Left Polarity 277V
White
HTEK12CL-BL
End Feed, Right Polarity 277V
Black
HTEK12CL-WH
End Feed, Right Polarity 277V
White
Current Limiting Circuit Breakers – Order Separately
Dimensions
1 27/32"
4 29/32"
4 29/32"
Ordering Example: TCLF11BL and TCL5BL
Cat. No.
Description
Wattage
Finish
TCL0.5
0.5A, 120V Current Limiting Circuit Breaker
60W
BL, WH
TCL2
2A, 120V Current Limiting Circuit Breaker
240W
BL, WH
TCL2
2A, 120V Current Limiting Circuit Breaker
240W
BL, WH
TCL3
3A, 120V Current Limiting Circuit Breaker
360W
BL, WH
TCL4
4A, 120V Current Limiting Circuit Breaker
480W
BL, WH
TCL5
5A, 120V Current Limiting Circuit Breaker
600W
BL, WH
TCL6
6A, 120V Current Limiting Circuit Breaker
720W
BL, WH
TCL7
7A, 120V Current Limiting Circuit Breaker
840W
BL, WH
TCL8
8A, 120V Current Limiting Circuit Breaker
960W
BL, WH
TCL9
9A, 120V Current Limiting Circuit Breaker
1080W
BL, WH
TCL10
10A, 120V Current Limiting Circuit Breaker
1200W
BL, WH
TCL12
12A, 120V Current Limiting Circuit Breaker
1440W
BL, WH
TCL14
14A, 120V Current Limiting Circuit Breaker
1680W
BL, WH
HTCL0.25
0.25A, 277V Current Limiting Circuit Breaker1
69W
BL, WH
HTCL0.50
0.50A, 277V Current Limiting Circuit Breaker1
138W
BL, WH
HTCL0.75
0.75A, 277V Current Limiting Circuit Breaker 207W
BL, WH
HTCL1.00
1.00A, 277V Current Limiting Circuit Breaker1
277W
BL, WH
HTCL2.50
2.50A, 277V Current Limiting Circuit Breaker 692W
BL, WH
HTCL5.00
5.00A, 277V Current Limiting Circuit Breaker1
1385W
BL, WH
HTCL7.50
7.50A, 277V Current Limiting Circuit Breaker 2077W
BL, WH
HTCL10.0
10.0A, 277V Current Limiting Circuit Breaker 2770W
BL, WH
HTCL15.0
15.0A, 277V Current Limiting Circuit Breaker1
4155W
BL, WH
1
1
1
1
Compatible with HD Commercial Current Limiting Feeds (HTEK11, HTEK12) only.
1
Juno Lighting Group | Current Limiting Solutions
9
Energy Codes
Current energy codes impacting trac lighting applications.
ASHRAE/IESNA Standard 90.1-2013
9.1.4 Interior and Exterior Luminaire Wattage. Luminaire wattage, when used to calculate
either installed interior lighting power or installed exterior lighting power, shall be
determined in accordance with the following criteria:
c. For line-voltage lighting track and plug-in busway, designed to allow the addition
and/or relocation of luminaires without altering the wiring of the system,
the wattage shall be
1. The specified wattage of the luminaires included in the system with a
minimum of 30 W/lin ft or
2. The wattage limit of the system’s circuit breaker or
3. The wattage limit of other permanent current-limiting device(s) on the system.
2013 Building Energy Efficiency Standards for Residential and
Nonresidential Buildings (California Title 24)
SECTION 130.0 – LIGHTING CONTROLS AND EQUIPMENT – GENERAL
Juno Lighting Group
1300 South Wolf Road
Des Plaines, IL 60018
Ph: 847.827.9880
www.junolightinggroup.com
Regional Offices & Warehouses
California
Illinois
Indiana
Pennsylvania
Texas
Ontario, CN
(c) Luminaire classification and power. Luminaires shall be classified and wattage
determined as follows:
7. Line-voltage lighting track and plug-in busway which allows the addition or
relocation of luminaires without altering the wiring of the system. The wattage
of such luminaires shall be determined by one of the following methods:
A. The wattage of line voltage busway and track rated for more than 20 amperes
shall be the total volt-ampere rating of the branch circuit feeding the busway
and track.
B. The wattage of line voltage busway and track rated for 20 amperes or less
shall be determined by one of the following methods:
i. The volt-ampere rating of the branch circuit feeding the track or busway; or
ii. The higher of the rated wattage of all of the luminaires included in the
system, where luminaire classification and wattage is determined
according to the applicable provisions in Section 130.0(c), or 45 watts
per linear foot; or
iii. When using a line-voltage track lighting integral current limiter, the higher
of the volt-ampere rating of an integral current limiter controlling the track
or busway, or 12.5 watts per linear foot of track or busway. An Integral
current limiter shall be certified to the Energy Commission in accordance
with Section 110.9, and shall comply with the Lighting Control Installation
Requirements in accordance with Section 130.4, to qualify to use
subsection Biii to determine luminaire power; or
iv. When using a dedicated track lighting supplementary overcurrent
protection panel, the sum of the ampere (A) rating of all of the overcurrent
protection devices times the branch circuit voltages. Track lighting
supplementary overcurrent protection panels shall comply with the
applicable requirements in Section 110.9, and shall comply with the
Lighting Control Installation Requirements in accordance with Section
130.4, to qualify to use subsection Biv to determine luminaire power.
To learn more about Juno Current Limiting Solutions,
please visit us at www.junolightinggroup.com.
©2016 Acuity Brands Lighting, Inc. The marks appearing in this catalog
are trademarks of Acuity Brands Lighting, Inc. Products shown in this
brochure may be covered by U.S. and international patents and patents
pending. Specifications subject to change without notice.
Printed in the U.S.A. LIT-JUNO-CL-FS-BRO 4/2016
Download