Current Limiting Solutions Innovative current limiting solutions for optimal trac lighting performance in an energy conscious world Current Limiting Solutions Table of Contents Code Compliance.......................................................2 Energy Code Calculations..........................................3 Current Limiting Subpanels...................................4-5 Current Limiting Feeds..........................................6-9 Trac-Master...........................................................7 Trac-Lites...............................................................7 Pendant Stem Kits................................................8 HD Commercial Trac.............................................9 Current Limiting Circuit Breakers........................9 Energy Codes............................................................10 Juno Lighting Group | Current Limiting Solutions Frustrated by your local energy codes? Are stringent energy codes impacting the way you highlight, promote and sell your merchandise? With energy codes throughout North America establishing power limits for commercial and retail lighting environments, the ability to apply trac lighting effectively is becoming increasingly difficult. Expressed in watts-per-square-foot, these codes mandate total power consumption of installed lighting fixtures for a given space. Because of its inherent flexibility, line-voltage trac lighting is typically assigned an arbitrary multiplier for purposes of energy calculations. Depending on the specific code, these multipliers can range from 30 to 70 watts per foot of trac, regardless of the actual power consumed by the specified fixtures. Therefore, even though a trac lighting installation may employ energy efficient fixtures, the watts-per-linear-foot power consumption formula still applies, effectively penalizing an otherwise energy-conscious design. Fortunately, there is a simple solution to this dilemma. By specifying a Juno current limiting solution with your trac lighting, energy codes permit the current limiter rating to be substituted for the linear footage formula. This means that trac installations can be designed using ultra-efficient fixtures, and effortlessly achieve code compliance. The Solutions Juno Lighting Group can help you meet the challenge of energy code compliance with either a Current Limiting Subpanel or Current Limiting Trac Feeds. The Subpanel solution installs between the branch circuit breaker and the trac lighting equipment and provides the lowest installed-cost solution. The Current Limiting Trac Feeds are intended to be installed at every trac feed location in place of a standard non-limiting feed, making it perfect for either new construction or upgrading existing circuits in a remodel or retrofit application. By incorporating either current limiting solution into company-wide trac lighting specifications, multi-facility organizations can be assured of lighting code compliance regardless of location. And no matter which system is best suited to a given application — subpanel or trac feed — Juno is your one-stop supplier for both solutions. How the Devices Work Both systems utilize supplementary current limiting circuit breakers, designed to limit available wattage based on the actual lighting design criteria, thereby avoiding the “watts-per-linear-foot penalty” imposed by energy codes. Trac lighting density and performance can be optimized, and configuration flexibility can be retained, without exceeding code-mandated power utilization limits. Optimize Your Energy Usage To optimize your energy usage and to maximize operating cost savings, combining energy efficient LED, high-performance ceramic metal halide (CMH) and economical compact fluorescent trac fixtures with either current limiting solution can reduce calculated energy use by as much as 75% or more versus standard halogen fixtures. This enables you to provide the lighting you need to effectively highlight merchandise and increase sales. Juno Lighting Group | Current Limiting Solutions 1 Current Limiting Solutions Code Compliance Case Study Background A leading specialty retailer with more than 1,000 locations nationwide planned to renovate each location. The rebranding efforts of the retail store locations included extensive trac lighting, providing the retailer with the flexibility to move, replace and redesign merchandising displays. With their rebranding efforts, the retailer recognized that greater efficiencies could be realized, not only in energy, but in overall maintenance costs by using Juno’s energy efficient, high performance LED trac fixtures. But this energy savings wasn’t enough when the new energy codes were enforced. Challenge With new energy codes throughout North America placing a mandatory limit on lighting density, trac lighting had an additional burden: an automatic VA (wattage) calculation per linear foot of trac. ASHRAE 90.1, the basis for many municipal energy codes around the country, assigns 30-watts per linear foot of trac. California’s Title 24 code assigns 45-watts and other more stringent codes may assign up to 70-watts per linear foot. Using California Title 24’s 45-watts per linear foot calculation, the retailer’s lighting layout had the calculated potential of using over 35,000 watts in a single store according to the energy code. This was an enormous exaggeration above the actual planned wattage of 7000 watts per store and 8.75-watts per linear foot of trac. With stores projected to open in just a few weeks, redesigning the stores again and eliminating a large portion of trac lighting was not an option. Solution To solve this problem, the retailer called on the expertise of their local Juno Lighting Group National Account Sales Manager. Working around the clock to meet a nearly impossible build schedule, and working closely with the California Energy Commission to obtain early acceptance and to avoid delaying any store openings, the solution was a sub-branch current limiting panel. This panel would limit the amount of wattage used on each trac, consequently eliminating the penalty for the calculated potential maximum load/unused wattage. The Juno Current Limiting Subpanel reduced the retailer’s calculated potential/ unused wattage by over 75%. In fact, the retailer selected their current limiters to total 8000 watts, leaving them with additional flexibility for expansion while still easily complying with the local energy codes. Juno. Solutions. 2 Juno Lighting Group | Current Limiting Solutions Energy Code Calculations Illustrated below is an example of what current limiting means for trac lighting relative to today’s energy codes. The standard layout without a current limiting solution consists of 100’ of single circuit trac (4 circuits x 25’ each) with 32 LED trac fixtures, each consuming 24W maximum, for a total connected load of 768W. Per the Title 24 energy code, the wattage calculation would be a much greater 4500W. The scenario with the Trac-Master Current Limiting Subpanel uses the original 100’ of single circuit trac, broken down into four 25’ runs, with each monitored by a 2-Amp current limiting supplementary protector that is closely matched to the actual connected load plus a small buffer. This results in the minimum calculated watts per the energy codes, making the wattage calculation independent of trac length. In a real application, there would be many more trac lighting circuits, resulting in an even greater calculated wattage reduction. Calculations Example Without Current Limiting Track length determines wattage calculation Actual Connected Load = 24W x 32 Fixtures = 768W 100 ft of trac = 4500W* *Based on 45W/ft multiplier of California Title 24 With Current Limiting 2A, 240W 2A, 240W 2A, 240W Branch Circuit Breaker Panel 2A, 240W Trac-Master Current Limiting Control Panel Actual Connected Load = 24W x 32 Fixtures = 768W Same 100 ft of trac: 2A@120V = 240W x 4 circuits = 960W total Juno Lighting Group | Current Limiting Solutions 3 Current Limiting Solutions Current Limiting Subpanels The Juno Current Limiting Subpanel permits you to take full advantage of any line voltage trac lighting without being penalized by watts-per-linear-foot energy code calculations. The subpanel is typically installed out-of-sight in an electrical control room, providing a centralized location for installation wiring and breaker access in the event of a circuit overload. The Current Limiting Subpanel installs between the branch circuit breaker and the trac lighting equipment. This limits the amount of power that is available to operate the trac circuit to only the wattage needed per the lighting plan. Installation labor is minimized since multiple trac runs can be fed from a single current limiting circuit breaker. The subpanel is offered in any configuration from 1 thru 42 circuits and is available in either surface or flush mount versions. Current limiting is provided by supplementary current limiting breakers that are selected at the time of order based on the actual lighting loads specified. Breakers are rated 120/277V and are available in 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, 13A and 15A current ratings. Note that Juno recommends that breakers be loaded to maximum of 80% of rating to avoid nuisance tripping. All Current Limiting Subpanels are factory pre-assembled and customized for your specific application . . . no programming is required. Complimentary factory assistance is available to guide you through the simple specification process. 4 Juno Lighting Group | Current Limiting Solutions Current Limiting Subpanels Ordering Information and Dimensions Surface Mount Cat. No. Description Surface Mount, 1 Circuit Surface Mount, 2 Circuit Surface Mount, 3 Circuit Surface Mount, 4 Circuit Surface Mount, 5 Circuit Surface Mount, 6 Circuit Surface Mount, 7 Circuit Surface Mount, 8 Circuit Surface Mount, 9 Circuit Surface Mount, 10 Circuit Surface Mount, 11 Circuit Surface Mount, 12 Circuit CLS1M CLS2M CLS3M CLS4M CLS5M CLS6M CLS7M CLS8M CLS9M CLS10M CLS11M CLS12M Cat. No. Description Surface Mount, 6 Circuit Surface Mount, 7 Circuit Surface Mount, 8 Circuit Surface Mount, 9 Circuit Surface Mount, 10 Circuit Surface Mount, 11 Circuit Surface Mount, 12 Circuit Surface Mount, 13 Circuit Surface Mount, 14 Circuit Surface Mount, 15 Circuit Surface Mount, 16 Circuit Surface Mount, 17 Circuit Surface Mount, 18 Circuit Surface Mount, 19 Circuit Surface Mount, 20 Circuit Surface Mount, 21 Circuit CLS6 CLS7 CLS8 CLS9 CLS10 CLS11 CLS12 CLS13 CLS14 CLS15 CLS16 CLS17 CLS18 CLS19 CLS20 CLS21 4-12 Circuit Panel 9 1/16" 12 3/4" 3 15/16" Flush Mount 6-21 Circuit Panel 14 1/4" 17 7/8" 3 13/16" Cat. No. Description Surface Mount, 22 Circuit Surface Mount, 23 Circuit Surface Mount, 24 Circuit Surface Mount, 25 Circuit Surface Mount, 26 Circuit Surface Mount, 27 Circuit Surface Mount, 28 Circuit Surface Mount, 29 Circuit 33 13/16" Surface Mount, 30 Circuit Surface Mount, 31 Circuit Surface Mount, 32 Circuit Surface Mount, 33 Circuit Surface Mount, 34 Circuit Surface Mount, 35 Circuit Surface Mount, 36 Circuit Surface Mount, 37 Circuit Surface Mount, 38 Circuit Surface Mount, 39 Circuit 3 13/16" Surface Mount, 40 Circuit Surface Mount, 41 Circuit Surface Mount, 42 Circuit CLS22 CLS23 CLS24 CLS25 CLS26 CLS27 CLS28 CLS29 CLS30 CLS31 CLS32 CLS33 CLS34 CLS35 CLS36 CLS37 CLS38 CLS39 CLS40 CLS41 CLS42 Facilitates compliance with Title 24 2013, ASHRAE 90.1 and other energy codes 22-42 Circuit Panel 14 1/2" Cat. No. Description 15 7/16" CLS6F 14 Flush 1/4" Mount, 6 Circuit CLS7F Flush Mount, 7 Circuit CLS8F Flush Mount, 8 Circuit CLS9F Flush Mount, 9 Circuit CLS10F 19 1/8" Flush Mount, 10 Circuit 17 7/8" CLS11F Flush Mount, 11 Circuit CLS12F Flush Mount, 12 Circuit CLS13F Flush Mount, 13 Circuit CLS14F Flush Mount, 14 Circuit CLS15F Flush Mount, 15 Circuit CLS16F Flush Mount, 16 Circuit 3 13/16" 3 13/16" CLS17F Flush Mount, 17 Circuit CLS18F Flush Mount, 18 Circuit CLS19F Flush Mount, 19 Circuit CLS20F Flush Mount, 20 Circuit CLS21F Flush Mount, 21 Circuit Cat. No. 6-21 Circuit Panel 15 7/16" 19 1/8" 3 13/16" Description 15 7/16" CLS22F14 1/2" Flush Mount, 22 Circuit CLS23F Flush Mount, 23 Circuit CLS24F Flush Mount, 24 Circuit CLS25F Flush Mount, 25 Circuit CLS26F Flush Mount, 26 Circuit CLS27F Flush Mount, 27 Circuit CLS28F Flush Mount, 28 Circuit CLS29F 35 Flush 1/8" Mount, 29 Circuit 33 13/16" CLS30F Flush Mount, 30 Circuit CLS31F Flush Mount, 31 Circuit CLS32F Flush Mount, 32 Circuit CLS33F Flush Mount, 33 Circuit CLS34F Flush Mount, 34 Circuit CLS35F Flush Mount, 35 Circuit CLS36F Flush Mount, 36 Circuit CLS37F Flush Mount, 37 Circuit CLS38F Flush Mount, 38 Circuit CLS39F 3 13/16" Flush Mount, 39 Circuit 3 13/16" CLS40F Flush Mount, 40 Circuit CLS41F Flush Mount, 41 Circuit CLS42F Flush Mount, 42 Circuit 22-42 Circuit Panel 15 7/16" 35 1/8" 3 13/16" NOTE: Individual current limiting circuit breaker ratings are determined by the electrical layout drawings. A submittal package will be provided by Juno Lighting Group for customer approval following receipt of order. Current limiting circuit breaker ratings and panel position must be provided at the time of order but are not required to be specified as part of the catalog number. Juno Lighting Group | Current Limiting Solutions 5 Current Limiting Solutions Current Limiting Feeds Juno Current Limiting Feeds are the perfect solution for new construction or for bringing existing Juno line voltage trac lighting applications into conformance with today’s stringent energy codes. They enable you to take full advantage of energy efficient, high-performance LED, ceramic metal halide and fluorescent trac fixtures without being penalized by watts-per-linear-foot code calculations, reducing calculated watts by as much as 75% or more. Current Limiting Feeds are designed to take the place of standard non-limiting feeds and are installed at every trac feed location. The feeds are compact and mount close to the ceiling for an unobtrusive appearance. Available in both end feed and in-line feed configurations, the Current Limiting Feeds can be specified for either Trac-Master 1-circuit, Trac-Master 2-circuit, HD Commercial 2-circuit or Trac-Lites 1-circuit trac systems. In-line feeds and 2-circuit end feeds are designed to accept up to two current limiting circuit breakers simultaneously. Feeds are supplied with tamper-resistant cover screws and screwdriver bits making installation convenient and future tampering impractical. Current limiting circuit breakers (ordered separately) are available in increments from 0.25A to 15A, enabling selection that closely matches the planned wattage use. Colorcoded ON/OFF indication clearly identifies their status and they are easily resettable in the event of an overload situation. 6 Juno Lighting Group | Current Limiting Solutions Current Limiting Feeds Ordering Information and Dimensions Trac-Master Mini End Feeds Cat. No. Description Trac Type Finish TCLFM11BL Mini End Feed 1-Circuit Black TCLFM11SL Mini End Feed 1-Circuit Silver TCLFM11WH Mini End Feed 1-Circuit White Cat. No. Description Trac Type Finish TCLF11BL End Feed 1-Circuit Black TCLF11SL End Feed 1-Circuit Silver TCLF11WH End Feed 1-Circuit White TUCLF11BL End Feed 2-Circuit Black TUCLF11SL End Feed 2-Circuit Silver TUCLF11WH End Feed 2-Circuit White End Feeds In-Line Feeds Cat. No. Description Trac Type Finish TCLF21BL In-Line Feed 1-Circuit Black TCLF21SL In-Line Feed 1-Circuit Silver TCLF21WH In-Line Feed 1-Circuit White TUCLF21BL In-Line Feed 2-Circuit Black TUCLF21SL In-Line Feed 2-Circuit Silver TUCLF21WH In-Line Feed 2-Circuit White Cat. No. Description Trac Type Finish RCLFM11BL Mini End Feed 1-Circuit Black Dimensions 5 3/4" 1 7/8" 1 1/4" Dimensions 5 7/8" 1 1/4" 4 5/8" 5 3/16" Dimensions 7 1/8" 1 1/4" 4 5/8" 5 3/16" Trac-Lites Mini End Feeds RCLFM11BZ Mini End Feed 1-Circuit Bronze RCLFM11SL Mini End Feed 1-Circuit Silver RCLFM11WH Mini End Feed 1-Circuit White Cat. No. Description Trac Type Finish RCLF11BL End Feed 1-Circuit Black RCLF11BZ End Feed 1-Circuit Bronze RCLF11SL End Feed 1-Circuit Silver RCLF11WH End Feed 1-Circuit White Cat. No. Description Trac Type Finish RCLF21BL In-Line Feed 1-Circuit Black RCLF21BZ In-Line Feed 1-Circuit Bronze RCLF21SL In-Line Feed 1-Circuit Silver RCLF21WH In-Line Feed 1-Circuit White End Feeds In-Line Feeds Dimensions 5 1/2" 1 7/8" 1 1/16" Dimensions 5 7/8" 1 1/4" 4 5/8" 5 3/16" Dimensions 7 1/8" 1 1/4" 4 5/8" 5 3/16" Juno Lighting Group | Current Limiting Solutions 7 Current Limiting Solutions Current Limiting Feeds Ordering Information and Dimensions Pendant Stem Kits (For Trac-Master or Trac-Lites) T-Bar Ceiling Mount Cat. No. Description Finish T90CLF-12-BL T-Bar Ceiling Kit, 12” Black T90CLF-12-BZ T-Bar Ceiling Kit, 12” Bronze T90CLF-12-SL T-Bar Ceiling Kit, 12” Silver T90CLF-12-WH T-Bar Ceiling Kit, 12” White T90CLF-18-BL T-Bar Ceiling Kit, 18” Black T90CLF-18-BZ T-Bar Ceiling Kit, 18” Bronze T90CLF-18-SL T-Bar Ceiling Kit, 18” Silver T90CLF-18-WH T-Bar Ceiling Kit, 18” White T90CLF-24-BL T-Bar Ceiling Kit, 24” Black T90CLF-24-BZ T-Bar Ceiling Kit, 24” Bronze T90CLF-24-SL T-Bar Ceiling Kit, 24” Silver T90CLF-24-WH T-Bar Ceiling Kit, 24” White T90CLF-36-BL T-Bar Ceiling Kit, 36” Black T90CLF-36-BZ T-Bar Ceiling Kit, 36” Bronze T90CLF-36-SL T-Bar Ceiling Kit, 36” Silver T90CLF-36-WH T-Bar Ceiling Kit, 36” White T90CLF-48-BL T-Bar Ceiling Kit, 48” Black T90CLF-48-BZ T-Bar Ceiling Kit, 48” Bronze T90CLF-48-SL T-Bar Ceiling Kit, 48” Silver T90CLF-48-WH T-Bar Ceiling Kit, 48” White Cat. No. Description Finish Rigid Ceiling Mount T91CLF-12-BL Rigid Ceiling Kit, 12” Black T91CLF-12-BZ Rigid Ceiling Kit, 12” Bronze T91CLF-12-SL Rigid Ceiling Kit, 12” Silver T91CLF-12-WH Rigid Ceiling Kit, 12” White T91CLF-18-BL Rigid Ceiling Kit, 18” Black T91CLF-18-BZ Rigid Ceiling Kit, 18” Bronze T91CLF-18-SL Rigid Ceiling Kit, 18” Silver T91CLF-18-WH Rigid Ceiling Kit, 18” White T91CLF-24-BL Rigid Ceiling Kit, 24” Black T91CLF-24-BZ Rigid Ceiling Kit, 24” Bronze T91CLF-24-SL Rigid Ceiling Kit, 24” Silver T91CLF-24-WH Rigid Ceiling Kit, 24” White T91CLF-36-BL Rigid Ceiling Kit, 36” Black T91CLF-36-BZ Rigid Ceiling Kit, 36” Bronze T91CLF-36-SL Rigid Ceiling Kit, 36” Silver T91CLF-36-WH Rigid Ceiling Kit, 36” White T91CLF-48-BL Rigid Ceiling Kit, 48” Black T91CLF-48-BZ Rigid Ceiling Kit, 48” Bronze T91CLF-48-SL Rigid Ceiling Kit, 48” Silver T91CLF-48-WH Rigid Ceiling Kit, 48” White 8 Juno Lighting Group | Current Limiting Solutions Dimensions 6 3/16" 2 1/16" 12" to 48" Nominal Stem Length 1" 10 1/8" Dimensions 6 3/16" 2 1/16" 12" to 48" Nominal Stem Length 1" 10 1/8" Current Limiting Feeds Ordering Information and Dimensions HD Commercial Trac End Feeds Cat. No. Description Finish TEK11CL-BL End Feed, Left Polarity 120V Black TEK11CL-WH End Feed, Left Polarity 120V White TEK12CL-BL End Feed, Right Polarity 120V Black TEK12CL-WH End Feed, Right Polarity 120V White HTEK11CL-BL End Feed, Left Polarity 277V Black HTEK11CL-WH End Feed, Left Polarity 277V White HTEK12CL-BL End Feed, Right Polarity 277V Black HTEK12CL-WH End Feed, Right Polarity 277V White Current Limiting Circuit Breakers – Order Separately Dimensions 1 27/32" 4 29/32" 4 29/32" Ordering Example: TCLF11BL and TCL5BL Cat. No. Description Wattage Finish TCL0.5 0.5A, 120V Current Limiting Circuit Breaker 60W BL, WH TCL2 2A, 120V Current Limiting Circuit Breaker 240W BL, WH TCL2 2A, 120V Current Limiting Circuit Breaker 240W BL, WH TCL3 3A, 120V Current Limiting Circuit Breaker 360W BL, WH TCL4 4A, 120V Current Limiting Circuit Breaker 480W BL, WH TCL5 5A, 120V Current Limiting Circuit Breaker 600W BL, WH TCL6 6A, 120V Current Limiting Circuit Breaker 720W BL, WH TCL7 7A, 120V Current Limiting Circuit Breaker 840W BL, WH TCL8 8A, 120V Current Limiting Circuit Breaker 960W BL, WH TCL9 9A, 120V Current Limiting Circuit Breaker 1080W BL, WH TCL10 10A, 120V Current Limiting Circuit Breaker 1200W BL, WH TCL12 12A, 120V Current Limiting Circuit Breaker 1440W BL, WH TCL14 14A, 120V Current Limiting Circuit Breaker 1680W BL, WH HTCL0.25 0.25A, 277V Current Limiting Circuit Breaker1 69W BL, WH HTCL0.50 0.50A, 277V Current Limiting Circuit Breaker1 138W BL, WH HTCL0.75 0.75A, 277V Current Limiting Circuit Breaker 207W BL, WH HTCL1.00 1.00A, 277V Current Limiting Circuit Breaker1 277W BL, WH HTCL2.50 2.50A, 277V Current Limiting Circuit Breaker 692W BL, WH HTCL5.00 5.00A, 277V Current Limiting Circuit Breaker1 1385W BL, WH HTCL7.50 7.50A, 277V Current Limiting Circuit Breaker 2077W BL, WH HTCL10.0 10.0A, 277V Current Limiting Circuit Breaker 2770W BL, WH HTCL15.0 15.0A, 277V Current Limiting Circuit Breaker1 4155W BL, WH 1 1 1 1 Compatible with HD Commercial Current Limiting Feeds (HTEK11, HTEK12) only. 1 Juno Lighting Group | Current Limiting Solutions 9 Energy Codes Current energy codes impacting trac lighting applications. ASHRAE/IESNA Standard 90.1-2013 9.1.4 Interior and Exterior Luminaire Wattage. Luminaire wattage, when used to calculate either installed interior lighting power or installed exterior lighting power, shall be determined in accordance with the following criteria: c. For line-voltage lighting track and plug-in busway, designed to allow the addition and/or relocation of luminaires without altering the wiring of the system, the wattage shall be 1. The specified wattage of the luminaires included in the system with a minimum of 30 W/lin ft or 2. The wattage limit of the system’s circuit breaker or 3. The wattage limit of other permanent current-limiting device(s) on the system. 2013 Building Energy Efficiency Standards for Residential and Nonresidential Buildings (California Title 24) SECTION 130.0 – LIGHTING CONTROLS AND EQUIPMENT – GENERAL Juno Lighting Group 1300 South Wolf Road Des Plaines, IL 60018 Ph: 847.827.9880 www.junolightinggroup.com Regional Offices & Warehouses California Illinois Indiana Pennsylvania Texas Ontario, CN (c) Luminaire classification and power. Luminaires shall be classified and wattage determined as follows: 7. Line-voltage lighting track and plug-in busway which allows the addition or relocation of luminaires without altering the wiring of the system. The wattage of such luminaires shall be determined by one of the following methods: A. The wattage of line voltage busway and track rated for more than 20 amperes shall be the total volt-ampere rating of the branch circuit feeding the busway and track. B. The wattage of line voltage busway and track rated for 20 amperes or less shall be determined by one of the following methods: i. The volt-ampere rating of the branch circuit feeding the track or busway; or ii. The higher of the rated wattage of all of the luminaires included in the system, where luminaire classification and wattage is determined according to the applicable provisions in Section 130.0(c), or 45 watts per linear foot; or iii. When using a line-voltage track lighting integral current limiter, the higher of the volt-ampere rating of an integral current limiter controlling the track or busway, or 12.5 watts per linear foot of track or busway. An Integral current limiter shall be certified to the Energy Commission in accordance with Section 110.9, and shall comply with the Lighting Control Installation Requirements in accordance with Section 130.4, to qualify to use subsection Biii to determine luminaire power; or iv. When using a dedicated track lighting supplementary overcurrent protection panel, the sum of the ampere (A) rating of all of the overcurrent protection devices times the branch circuit voltages. Track lighting supplementary overcurrent protection panels shall comply with the applicable requirements in Section 110.9, and shall comply with the Lighting Control Installation Requirements in accordance with Section 130.4, to qualify to use subsection Biv to determine luminaire power. To learn more about Juno Current Limiting Solutions, please visit us at www.junolightinggroup.com. ©2016 Acuity Brands Lighting, Inc. The marks appearing in this catalog are trademarks of Acuity Brands Lighting, Inc. Products shown in this brochure may be covered by U.S. and international patents and patents pending. Specifications subject to change without notice. Printed in the U.S.A. LIT-JUNO-CL-FS-BRO 4/2016