Series Lamping XX Clear Glass only SI Clear Glass w/ Satine Inlay OI Clear Glass w/ Opal Inlay MI Clear Glass w/ Microprismatic Inlay PC1 Prismatic Lens SD1 Satine Lens 2T5 1T8 M125R2 Recessed Flanged / Flush Endcaps 2T8 1T5HO 2T5HO M125 For Concrete Pour Only 1 Shielding 1T5 M125R1 Recessed Flanged 2 IK10 rated. 415/16" (125mm) 2 3 SH and TS mountings only. M125R1-1T5-TS 1 31/2" Scale = 1 : 4 M125R1-1T5-TS-MT 12 7 (37mm) 10 4 /16" 15 37/16" (125mm) (88mm) 8 Selux Corp. © 2013 TEL (845) 834-1400 FAX (845) 834-1401 www.selux.us M125R-0213-01 (ss-v1.2) 6 9 4 Union Made Affiliated with IBEW Local 363 2. Ballast - Electronic, high power factor, class "P," type "A" sound rating. Specify 120v, 277v, or 347v. Ballast is factory pre-wired with leads to one end of fixture. Cold Weather ballast (-20°F/ -29°C) available with CW option. See p. 8 for standard dimming ballast. 3. EM Battery Packs - (not shown) Standard EM Battery Packs (EM1 EM3) by IOTATM. For detailed information (i.e. operated lamps and average lumen ratings) please see IOTATM Product specification sheet. 4. Gear Tray - White powder-coated, cold-rolled steel. Gear tray installed as a complete electrical unit fully accessible and removable from below ceiling. 5. Lamps - Single or double T5 (21W 3’, 28W 4’), T5HO (39W 3’, 54W 4’), or T8 (25W 3’, 32W 4’) IP65 IK10 Finish length rounded to the next highest foot. Factory will supply layout drawings. Individual fixtures cannot be field joined. 1. Housing - Continuous, 6063-T6 extruded aluminum profile up to 4’ long. Die cast aluminum end caps. Housing and end caps made from low copper, marine grade aluminum alloy. Two water-tight nipple connectors join fixtures in run configurations. See p. 7 for details. NRTL Listed for Wet Locations (i.e. UL, CSA) Mounting WH White 003 3 foot 004 4 foot BK Black RUN Nominal SV Silver Lengths* SP Specify * For actual lengths see Premium p5. For other lengths, configurations indicate nominal Color Not available with 347V. 11 (90mm) 57/8" (149mm) SH Suspension Bracket TS 1” Studs (Factory installed) RC Rotating Crossbar PM Perimiter Mount MTB6 Metal Box Concrete Pour Nominal Length Suspension Brackets (SH) 15 5 Mounting Not available with T5HO. 12 4 17/16" Options _ Shielding 41/2" Series Lamping _ 5 Not available with 2T5HO. _ Nominal Length Voltage 120 277 347 6 Finish _ Voltage Options MT2 Media Trunking EM13,4,5 Stand-by Battery Pack (ISL-28) EM24,5 Stand-by Battery Pack (ISL-54) EM34,5 Stand-by Battery Pack (ISL-540) DM Non-Standard Driver DMA5 Lutron EcoSystem DME5 Lutron Hi-Lume 3D EcoSystem Dimming DMH5 Lutron EcoSystem H-Series Dimming DM35 Lutron Hi-Lume 3D 3-wire Dimming DM45 Lutron Hi-Lume 3D 4-wire Dimming DM75 Advance: Mark 7 Dimming (0-10V) DM105 Advance: Mark 10 Dimming (2-wire) TM Tandem Wiring FS4 Single Fusing CW Cold Weather Ballast NC7 Nipple Connector (RUN only) For M125 Concrete Pour Only. 7Not required when MT is used. Rotating Crossbar 13 _ Perimiter Mount lamping by others. 6. Shielding - Choice of 4mm satine or clear polycarbonate prismatic lenses (IK10 with polycarbonate or satine lenses only); or tempered clear glass with optional satine, opal, or microprismatic inlays available. 7. Grommet - Rubber Grommet in 13 /16” feed hole provided for feed wire. 8. One piece Silicone Gasketing Fixture lens and end plates are fully gasketed (IP65 rated) for weather proofing, dust, and insect control. 9. Fixture Door - Secure, completely sealed at all points of entry from water, insects and dust. Two tamper-proof stainless steel screws allow access to lamp and gear tray. Door remains captive when servicing with corrosion protected steel safety cable on both ends. 10. Media Trunk - Provides raceway for additional cables, etc. and in continuous run or pattern applications. 11. Suspension Brackets - Bolted onto fixture or media trunk, located nominally every 4’. (Support wires or (Scale = 1 : 8) _ Qty: 53/8" Type: (135mm) Project: (115mm) M125 Transit Subway Linear Fluorescent Direct Tunnel Recessed rod supplied and installed by others). 12. Ø1/4" Threaded Rod - 1/4”-20 stud only. Couplers & Rod by others. 13. Rotating Crossbar - For inaccessible ceilings, adjustable for ceiling thicknesses from 1/4" to 2". Supplied, (2) per fixture, locate 6" (152mm) from each end of fixture. 14. Nipple Connector - (not shown) 3/8" IP nipple connector for water tight connection between luminaires in a run. Two connectors required per connection. Not required when MT is used. See p. 7 for details. 15. Emergency Battery Pack - For details, see p. 8. Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI. Selux premium colors (SP) are available, please specify from your Selux color selection guide. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Transit Subway Tunnel Photometry Linear Fluorescent Direct Recessed M125-1T5-SI COEFFICIENTS OF UTILIZATION - Zonal cavity method Satine Inlay/Clear Lens Catalog #: M125-1T5-SI-F-004 Lamp: 1F28T5 @ 2610 lumens Report #: 21581 Luminaire Efficiency: 73% Maximum Candela: 723 @ 18.5° 201 401 602 803 0° 90° Vertical Plane is parallel with the lamp. Vertical Plane is perpendicular to the lamp. DOWNLOAD IES FILE: http://www.selux.us/fileadmin/us/interior/ies_file/M125_IES.zip M125-2T5-SI ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 0-90 90-180 0-180 LUMENS %LAMP 580.37 972.84 1653.6 1900.73 0.00 1900.73 22.20 37.30 63.40 72.80 0.00 72.80 %FIXT. 30.50 51.20 87 100 0 100 COEFFICIENTS OF UTILIZATION - Zonal cavity method Satine Inlay/Clear Lens 401 Catalog #: M125-2T5-SI-F-004 Lamp: 2F28T5 @ 2610 lumens Report #: 21580 Luminaire Efficiency: 68% Maximum Candela: 1402 @ 8.5° DOWNLOAD IES FILE: 803 1204 1606 http://www.selux.us/fileadmin/us/interior/ies_file/M125_IES.zip Selux Corp. © 2013 M125R-0213-02 (ss-v1.2) 0° 90° Vertical Plane is parallel with the lamp. Vertical Plane is perpendicular to the lamp. ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 0-90 90-180 0-180 LUMENS %LAMP 1125.86 1863.81 3110.65 3563.2 .04 3563.24 21.60 35.70 59.60 68.30 0.00 68.30 %FIXT. 31.60 52.30 87.30 100 0 100 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Transit Subway Tunnel Linear Fluorescent Direct Recessed Photometry (cont’d) M125-1T8-MI COEFFICIENTS OF UTILIZATION - Zonal cavity method Microprismatic Inlay / Clear Lens Catalog #: M125-1T8-MI-F-004 Lamp: 1F32T8 @ 2850 lumens Report #: 4030 / SX545AA6(*) Luminaire Efficiency: 64% Maximum Candela: 910 @ 25° DOWNLOAD IES FILE: RC RW 0 1 2 3 4 5 6 7 8 9 10 235 469 0° 90° 704 939 80 70 50 30 70 50 30 10 70 50 30 10 50 30 10 50 30 10 DOWNLOAD IES FILE: ZONAL LUMEN SUMMARY Vertical Plane is parallel with the lamp. ZONE Vertical Plane is perpendicular to the lamp. 98 90 82 75 68 63 58 53 50 46 43 250 500 0° 90° 751 1001 98 86 75 66 58 52 47 42 38 35 32 98 83 70 59 51 45 39 35 31 28 25 98 80 65 54 46 39 34 30 26 23 21 96 88 80 73 66 61 56 52 48 45 42 96 84 74 65 57 51 46 41 38 34 32 96 81 69 59 50 44 39 34 31 28 25 96 79 64 54 45 39 34 29 26 23 21 Vertical Plane is parallel with the lamp. Vertical Plane is perpendicular to the lamp. http://www.selux.us/fileadmin/us/interior/ies_file/M125_IES.zip M125-1T8-XX Tempered Clear Lens 180° 0-30 0-40 0-60 0-90 90-180 0-180 90° DOWNLOAD IES FILE: 224 448 60° 895 0° RC RW 0 1 2 3 4 5 6 7 8 9 10 0° 90° 671 http://www.selux.us/fileadmin/us/interior/ies_file/M125_IES.zip Selux Corp. © 2013 M125R-0213-03 (ss-v1.2) LUMENS %LAMP 665.04 1150.01 1793.01 1974.77 0.03 1974.8 21.50 37.10 57.80 63.70 0.00 63.70 %FIXT. 33.70 58.20 90.80 100 0 100 30° 92 81 71 62 55 49 44 40 37 33 31 92 78 67 57 49 43 38 34 30 27 25 92 76 63 53 45 38 33 29 26 23 21 88 78 68 60 53 48 43 39 35 33 30 88 76 65 55 48 42 37 33 30 27 25 88 74 61 52 44 38 33 29 26 23 21 84 75 66 58 51 46 42 38 34 32 29 84 73 63 54 47 41 37 33 29 27 24 84 72 60 51 43 37 33 29 26 23 21 83 70 58 49 42 36 31 27 24 21 19 ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 0-90 90-180 0-180 LUMENS %LAMP 522.78 925.16 1691.17 2075.54 .06 2075.59 16.90 29.80 54.60 67 0 67.00 %FIXT. 25.20 44.60 81.50 100 0 100 COEFFICIENTS OF UTILIZATION - Zonal cavity method 150° 120° Catalog #: M125-1T8-XX-F-004 Lamp: 1F32T8 @ 2850 lumens Report #: 4031 / SX545AA7(*) Luminaire Efficiency: 73% Maximum Candela: 895 @ 30° 0 COEFFICIENTS OF UTILIZATION - Zonal cavity method Prismatic Lens Catalog #: M125-1T8-PC-F-004 Lamp: 1F32T8 @ 2850 lumens Report #: 4029 / SX545AA5(*) Luminaire Efficiency: 67% Maximum Candela: 811 @ 30° 0 Effective Floor Cavity Reflectance 0.20 http://www.selux.us/fileadmin/us/interior/ies_file/M125_IES.zip M125-1T8-PC 10 50 30 10 80 70 50 30 70 50 30 10 70 50 30 10 50 30 10 50 30 10 10 50 30 10 0 0 Effective Floor Cavity Reflectance 0.20 Vertical Plane is parallel with the lamp. Vertical Plane is perpendicular to the lamp. ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 0-90 90-180 0-180 LUMENS %LAMP 482.86 904.48 1822.86 268.28 0.03 2268.31 15.60 29.20 58.80 73.20 0.00 73.20 %FIXT. 21.30 39.90 80.40 100 0 100 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Transit Subway Tunnel Linear Fluorescent Direct Recessed Concrete Pour Mounting Details Mounting hardware by others. Outlet box and lamp(s) by others. 3’ fixture shown as reference. M125 Concrete Pour Housing (Side View) A B 119/32" (41mm) M125 Concrete Pour (Front View) 111/4" Fixture Dependant Length (286mm) Removable Cover Plate Feed Location for fixture in end cap. Fixture supplied with 12” feed cord and water-tight grommet M125 Concrete Pour (End Cap Detail) 7 11/4" /8" (32mm) Conduit Entry Holes (conduit by others) (32mm) 11/4" (32mm) 11/4" /32" (32mm) 31 1" (25mm) 321/32" (93mm) (25mm) 51/4" (133mm) M125 CONCRETE POUR DETAILS INDIVIDUAL LUMINAIRE 3 foot individual 4 foot individual A (Concrete Housing) 48.50" 60.31" (1232mm) (1532mm) T5 B (Flange) 45.31" 57.13" (1151mm) (1451mm) A (Concrete Housing) 50.27" 62.28" (1277mm) (1582mm) T8 B (Flange) 47.09" 59.09" (1196mm) (1501mm) For other lengths, lamping or configurations please specify overall length (in feet), accessories desired and sketch/drawing of configuration. Selux will detail project drawings upon order and supply submittal drawings for approval. If you have any questions, contact Selux customer service or applications engineering for assistance (1-800-SELUX-CS). Selux Corp. © 2013 M125R-0213-04 (ss-v1.2) In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Linear Fluorescent Direct Recessed Transit Subway Tunnel Individual Recessed Mounting Details Mounting hardware & lamps by others. 3’ fixture shown as reference. Weight: 5 lbs. without MT per foot. 7.5 lbs. with MT per foot. M125R1 Recessed Flanged Endcaps (Side View) A 25/8" (66mm) Feed location B M125R1 Recessed Flanged Endcaps (Mounting view, same orientation as Front Closed View) 13 /16" (21mm) Feed Hole suitable for 1/2” (13mm) chase nipple (by others) for watertight connection. Fixture supplied with 12” feed cord and water-tight grommet. M125R2 59/16" M125R1 59/16" Suspensions (142mm) M125R2 Recessed Flangeless Endcaps (Side View) 59/16" (142mm) (142mm) C 59/16" (142mm) A 25/8" (66mm) Feed location M125R1 Recessed Flanged Endcaps (Front Closed View) 2 1/2" (63mm) 1 1/2" (38mm) M125R2 M125R1 57/8" 33/4” (95mm) (149mm) M125 RECESSED MOUNTING DETAILS INDIVIDUAL LUMINAIRE 3 foot individual 4 foot individual 37.01" 48.82" T5 A (940mm) (1240mm) 37.95" 49.76" B (964mm) (1264mm) 25.83" 37.64" C (656mm) (956mm) 38.78" 50.79" A (985mm) (1290mm) T8 39.72" 51.73" B (1009mm) (1314mm) 27.60" 39.61" C (701mm) (1006mm) For other lengths, lamping, continuous runs or configurations please specify overall length (in feet), accessories desired and sketch/drawing of configuration. Selux will detail project drawings upon order and supply submittal drawings for approval. If you have any questions, contact Selux customer service or applications engineering for assistance (1-800-SELUX-CS). Selux Corp. © 2013 M125R-0213-05 (ss-v1.2) In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Linear Fluorescent Direct Recessed Transit Subway Tunnel Recessed Linear Run Mounting Details Nipple Connectors provide waterproof wiring between fixtures, connected in the field. Mounting hardware and lamps by others. For custom configurations and lengths please consult factory. Weight: 5 lbs. without MT per foot. 7.5 lbs. with MT per foot. M125R1/2-006-NC - 6 foot nominal Linear Run Configuration (using 2 x 3’ fixtures) C E A B E A D M125R1/2-008-NC - 8 foot nominal Linear Run Configuration (using 2 x 4’ fixtures) C B E A A E D M125R1/2-009-NC - 9 foot nominal Linear Run Configuration (using 3 x 3’ fixtures) A C E B E B E A D M125R1/2-010-NC - 10 foot nominal Linear Run Configuration (using 2 x 3’, 1 x 4’ fixtures) A E C E B 3’ E B 4’ A 3’ D M125R1/2-012-NC - 12 foot nominal Linear Run Configuration (using 3 x 4’ fixtures) A C E B E B E A D M125R1/2-012-NC - 12 foot nominal Linear Run Configuration (using 3 x 4’ fixtures) (Bottom View) M125 RECESSED MOUNTING DETAILS INDIVIDUAL LUMINAIRE 6 foot run 8 foot run 9 foot run 10 foot run 12 foot run A 5.59" (142mm) B 11.26" (286mm) C T5 D (M125 R1 only) 25.83" (656mm) 111.18" (2824mm) 112.13" (2848mm) 25.83" (656mm) 146.62" (3724mm) 147.56" (3748mm) (956mm) 74.09" (1882mm) 97.72" (2482mm) 75.04" (1906mm) E 98.66" (2506mm) 37.64" (956mm) C 77.64" (1972mm) T8 D (M125 R1 only) E 78.58" (1996mm) 27.60" (701mm) 116.50" (2959mm) 117.44" (2983mm) 27.60" (701mm) 101.65" (2582mm) 102.60" (2606mm) 39.61" (1006mm) 122.99" (3124mm) 123.94" (3148mm) 3’- 25.83" (656mm) /4’- 37.64" (956mm) 128.50" (3264mm) 129.45" (3288mm) 3’- 27.60" (701mm) /4’- 39.61" (1006mm) 37.64" 152.52" (3874mm) 153.46" (3898mm) 39.61" (1006mm) For other lengths, lamping, continuous runs or configurations please specify overall length (in feet), accessories desired and sketch/drawing of configuration. Selux will detail project drawings upon order and supply submittal drawings for approval. Individual fixtures cannot be field joined. If you have any questions, contact Selux customer service or applications engineering for assistance (1-800-SELUX-CS). Selux Corp. © 2013 M125R-0213-06 (ss-v1.2) In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Transit Subway Tunnel Mounting Details Linear Fluorescent Direct Recessed Standard Feed Location For all mountings. 13 /16" (21mm) Feed Hole suitable for 1/2" (13mm) chase nipple (by others) for water-tight connection to J-Box. Fixture supplied with 12” feed cord and water-tight grommet 23/8" (58mm) 25/8" (67mm) 25/8" (66mm) Top View Bottom View Nipple Connectors Water-tight Nipple Connectors supplied for all run configurations. Nipple connectors (NC) are not needed when Media Trunking (MT) is used. Bottom View 415/16" (125mm) Water-tight Silicone Gasket 1/16” (2mm) thick, pre-applied to one luminaire Inside View Side View Locking Nut Nipple Connectors Rubber Washer Selux Corp. © 2013 M125R-0213-07 (ss-v1.2) In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. M125 Linear Fluorescent Direct Recessed Transit Subway Tunnel Dimming Option Details Dimming DM7 (0-10V) DMH Digital Link (4-wire) DM4 Digital Link (4-wire) DM3(3-wire Dim) DMA DM 10 (2-wire) DM ( Non-Standard Driver) Lamping Voltage T5 T5HO T8 120V 14W 54W 17W 21W 25W 277V 80W 28W 32W 14W 24W 17W 120V 21W 39W 25W 277V 28W 54W 32W 28W 54W 32W 347V 14W 24W 17W 120V 21W 39W 25W 54W 28W 32W 277V 80W 14W 24W 17W 120V 21W 39W 25W 54W 28W 32W 277V 80W 14W 24W 17W 120V 21W 39W 25W 54W 28W 32W 277V 80W 24W 17W 120V 25W 54W 277V 32W Please specify Lamping Manufacturers: Standard Ballast Advance : Mark 7 Lutron : EcoSystem® H-Series Lutron : Hi-Lume 3D Lutron: Hi-Lume 3D Lutron : EcoSystem Advance: Mark 10 Please specify manufacturer and model number EM Stand-by Battery Packs Selux only uses name-brand, UL-listed fluorescent EM ballasts that in the event of a power failure, operates one of the existing lamps for 90 minutes. Comes with original manufacturer 5-year warranty. For wiring and maintenence information, please consult factory. End View 1.2” (29mm) 1.2” (30mm) Side View Mounting Points Lumen Output EM2 EM3 Lamps Operated Most 2’-4’ T5, up to Most 2’-4’ T5, 17-40W 28W or T8 linear T8, and most HO linear flourescent lamps flourescent lamps Most 2’4’ T5, up to 28W or T8 linear flourescent lamps Input Voltage 120/277V, 60Hz 120/277V 60Hz 120/277V 60Hz 425 500 n/a 700 Operation Time 21W T5 28W T5 39W T5HO 54W T5HO 90 min. 90 min. Average Lumen Ratings 500 n/a F25 T8 360 F32 T8 425 F28 T8 Selux Corp. © 2013 M125R-0213-08 (ss-v1.2) EM1 500 Lm (1 lamp) 825 Lm (1 lamp) 1300 Lm (1 lamp) 380 90 min. 850 800 1200 825 1300 650 630 700 1100 950 990 1100 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.