Earth Leakage C B6 Page 102 Tuesday, August 28, 2007 9:53 AM ELCB-1 Series C Moulded Case Circuit Breakers Earth Leakage Circuit Breakers General Information Applications Earth Leakage Moulded Case Breakers offer superior Class 1 ground fault protection and improved ground fault coordination capability, and are listed under UL489 and 1053 as well as CSA C22.2 No. 5 and 144 standards. Three-Phase, Four-Wire Loads For three-phase applications with line-to-neutral loads, select 4-pole earth leakage breakers and wire the neutral through the fourth (right) pole. Earth leakage ground fault protection differs from other types of systems in its level of sensitivity. The sensitivity of traditional devices is limited by the cumulative error of the residual current sensors and the placement of the phase and neutral conductors inside the current sensor. Typical Earth Leakage Circuit Breaker July 2007 Earth Leakage breakers and motor protectors are zero sequence sensing devices. They are factory supplied with a single sensor and ground fault relay built-in. This technique allows for protection sensitivities down to the 30 milliampere level. Earth Leakage breakers and motor protectors are provided with a full complement of easy adjustments. The ground fault pickup setting is adjustable from 0.03 to 30 amperes in eight steps, and the ground fault time delay setting is adjustable from instantaneous to 2.0 seconds in six steps. When the pickup is set to 30 mA, the time delay setting defaults internally to instantaneous only. Increased selectivity provides for improved coordination with upstream and downstream ground fault devices as well as the flexibility to adjust for transient currents. Three-Phase, Three-Wire Loads For applications with only threephase, three-wire, line-to-line connected loads, select 3-pole earth leakage breakers. Single-Phase Loads For single-phase, 3-wire applications, use a 3-pole earth leakage breaker and connect all conductors through the breaker. For single-phase, 2-wire applications, wire to L1 - L2 or L2 - L3. General Do not reverse feed. Do not apply on 400 Hz system. Voltage range: 110 480 Vac. Standard Features ■ ■ ■ ■ ■ Built-in push-to-trip button for functional testing. Trip window indicates red when the breaker has tripped on a ground fault. Form C bell alarm contact➀ for remote indication when the breaker has tripped under ground fault condition. Lockable adjustment seal helps prevent tampering with settings. Line and load terminals for bare cable connections. Accessories Optional Factory Installed Internal Accessories Earth leakage breakers use the same internal accessories as standard F-, Jand K-Frame Circuit Breakers. Internal accessories fit in the right-hand pole space and are available as factory modifications only. Optional External Accessories Earth Leakage Breakers use the same external accessories as the standard F-, J- and K-Frame circuit breakers. ➀ This Bell Alarm contact will not change state when the breaker has tripped on overload or short circuit condition. Page 102 For more information visit: www.EatonCanada.ca PG.29.03.T.K Earth Leakage C B6 Page 103 Tuesday, August 28, 2007 9:53 AM Series C Moulded Case Circuit Breakers Earth Leakage Circuit Breakers July 2007 ELCB-2 Selection Guide and Ordering Information F-Frame HMCP with Earth Leakage Ground Fault F-Frame Earth Leakage Ground Fault Breakers – Catalogue Numbers Amperes 25 kA at 480 VAC 3-Pole 65 kA at 480 VAC 4-Pole 3-Pole Continuous Amperes 100 kA at 480 VAC 4-Pole 3-Pole 4-Pole 15➀ 20➀ 25➀ 30➀ ELFD3015L ELFD3020L ELFD3025L ELFD3030L N/A N/A N/A N/A ELHFD3015L ELHFD3020L ELHFD3025L ELHFD3030L N/A N/A N/A N/A ELFDC3015L ELFDC3020L ELFDC3025L ELFDC3030L N/A N/A N/A N/A 35 40 45 50 60 70 80 90 100 110 125 150 ELFD3035L ELFD3040L ELFD3045L ELFD3050L ELFD3060L ELFD3070L ELFD3080L ELFD3090L ELFD3100L ELFD3110L ELFD3125L ELFD3150L ELFD4035L ELFD4040L ELFD4045L ELFD4050L ELFD4060L ELFD4070L ELFD4080L ELFD4090L ELFD4100L ELFD4110L ELFD4125L ELFD4150L ELHFD3035L ELHFD3040L ELHFD3045L ELHFD3050L ELHFD3060L ELHFD3070L ELHFD3080L ELHFD3090L ELHFD3100L ELHFD3110L ELHFD3125L ELHFD3150L ELHFD4035L ELHFD4040L ELHFD4045L ELHFD4050L ELHFD4060L ELHFD4070L ELHFD4080L ELHFD4090L ELHFD4100L ELHFD4110L ELHFD4125L ELHFD4150L ELFDC3035L ELFDC3040L ELFDC3045L ELFDC3050L ELFDC3060L ELFDC3070L ELFDC3080L ELFDC3090L ELFDC3100L ELFDC3110L ELFDC3125L ELFDC3150L ELFDC4035L ELFDC4040L ELFDC4045L ELFDC4050L ELFDC4060L ELFDC4070L ELFDC4080L ELFDC4090L ELFDC4100L ELFDC4110L ELFDC4125L ELFDC4150L J-Frame Earth Leakage Ground Fault Breakers – Catalogue Numbers Amperes 35 kA at 480 VAC 3-Pole 100 125 150 175 200 225 250 ELJD3100 ELJD3125 ELJD3150 ELJD3175 ELJD3200 ELJD3225 ELJD3250 65 kA at 480 VAC 4-Pole ELJD4100 ELJD4125 ELJD4150 ELJD4175 ELJD4200 ELJD4225 ELJD4250 3-Pole 100 kA at 480 VAC 4-Pole ELHJD3100 ELHJD3125 ELHJD3150 ELHJD3175 ELHJD3200 ELHJD3225 ELHJD3250 ELHJD4100 ELHJD4125 ELHJD4150 ELHJD4175 ELHJD4200 ELHJD4225 ELHJD4250 3-Pole 4-Pole ELJDC3100 ELJDC3125 ELJDC3150 ELJDC3175 ELJDC3200 ELJDC3225 ELJDC3250 ELJDC4100 ELJDC4125 ELJDC4150 ELJDC4175 ELJDC4200 ELJDC4225 ELJDC4250 K-Frame Earth Leakage Ground Fault Breakers – Catalogue Numbers Amperes 35 kA at 480 VAC 3-Pole 200 225 250 300 350 400 ELKD3200 ELKD3225 ELKD3250 ELKD3300 ELKD3350 ELKD3400 65 kA at 480 VAC 4-Pole ELKD4200 ELKD4225 ELKD4250 ELKD4300 ELKD4350 ELKD4400 3-Pole 100 kA at 480 VAC 4-Pole ELHKD3200 ELHKD3225 ELHKD3250 ELHKD3300 ELHKD3350 ELHKD3400 ELHKD4200 ELHKD4225 ELHKD4250 ELHKD4300 ELHKD4350 ELHKD4400 3-Pole 4-Pole ELKDC3200 ELKDC3225 ELKDC3250 ELKDC3300 ELKDC3350 ELKDC3400 ELKDC4200 ELKDC4225 ELKDC4250 ELKDC4300 ELKDC4350 ELKDC4400 Standard Line and Load Terminals – Included with Breaker Frame Wire Type (Number) Range of Conductors Terminal Material F-Frame F-Frame 35-100A 110-150A Cu/Al Cu/Al (1) #14-1/0 (1) #4-4/0 Steel Stainless Steel J-Frame 100-250A Cu/Al (1) #4-250 kcmil Aluminum K-Frame K-Frame 200-350A 400A Cu/Al Cu/Al (1) 250-500 kcmil (2) 3/0-250 kcmil Aluminum Aluminum Catalogue Number 3-Pole 3➀ ELHMCP003A0C 7➀ ELHMCP007C0C 15➀ ELHMCP015E0C 25➀ ELHMCP025X0C 30➀ ELHMCP030H1C 50 ELHMCP050K2C 70 ELHMCP070M2C 100 ELHMCP100R3C 150 ELHMCP150T4C 150 ELHMCP150U4C 3 ELHMCP003A0LC 7 ELHMCP007C0LC 15 ELHMCP015E0LC 25 ELHMCP025D0C 30 ELHMCP030H1LC 50 ELHMCP050G2C 70 ELHMCP070J2C 100 ELHMCP100L3C 100 ELHMCP100K3C HMCPs for Application with Motor Starters Equipped with Electrical Overload Relays 3➀ ELHMCPS003A0C 7➀ ELHMCPS007C0C 15➀ ELHMCPS015E0C 30➀ ELHMCPS030H1C 50 ELHMCPS050K2C 100 ELHMCPS100R3C 150 ELHMCPS150T4C 150 ELHMCPS140U4C J, K-Frame HMCP with Earth Leakage Ground Fault Continuous Amperes Catalogue Number 3-Pole 250 ELHMCP250A5 ELHMCP250C5 ELHMCP250D5 ELHMCP250F5 ELHMCP250G5 ELHMCP250J5 ELHMCP250K5 ELHMCP250L5 ELHMCP250W5 400 ELHMCP400D5 ELHMCP400F5 ELHMCP400G5 ELHMCP400J5 ELHMCP400K5 ➀ The ground fault pickup setting is adjustable from 0.03 to 10 amperes. PG.29.03.T.K For more information visit: www.EatonCanada.ca Page 103 Earth Leakage C B6 Page 104 Tuesday, August 28, 2007 9:53 AM ELCB-3 Series C Moulded Case Circuit Breakers Earth Leakage Circuit Breakers July 2007 Optional K-Frame Line and Load Terminals – Order Separately Wire Type (Number) Range of Conductors Terminal Material Catalogue Number Cu/Al Cu/Al (2) 250 kcmil (1) 500 kcmil Aluminum Aluminum 3TA401K➀ Cu/Al Cu/Al (2) 250 kcmil (1) 500 kcmil Aluminum Aluminum 4TA401K➁ Cu (1) 3-350 kcmil Copper T300K Cu (1) 3-350 kcmil Copper T300K Cu (1) 250-500 kcmil Copper T350K Cu (1) 250-500 kcmil Copper T350K Cu (1) 3/0-250 kcmil Copper 3T400K➀ Cu (1) 3/0-250 kcmil Copper 3T400K➁ ➀ Package of 3 terminals. ➁ Package of 4 terminals. Page 104 For more information visit: www.EatonCanada.ca PG.29.03.T.K