RESTART EARTH LEAKAGE NEW 2 Pole (230V) Restart Earth Leakage no overload protection NO Auxiliary contact output Code Idn Rated Current GW94817R GW94827R GW94837R GW94847R 30mA 25A 30mA 40A 30mA 30mA Type Nominal Voltage No. Modules No. Poles A 230V 4 2 A 230V 4 2 63A A 230V 4 2 80A A 230V 4 2 2 Pole (230V) Restart Earth Leakage Autotest no overload protection • With Auxiliary contact output • System with auto reset and weekly self-diagnosis of the earth leakage functions. • Self-diagnosis on the residual current device test is run without turning off the system’s power supply. • Function LEDs and programmable auxilliary contact. • Rated supply – 230V 50Hz, -15+10%. • Auxilliary can be programmed for 1Hz pulse for bell/buzzer or steady state for telephone dialler or other home management system. This is achieved by using internal bypass contacts during the test. Code Idn GW90901 GW90902 30mA 30mA Rated Current Type 25A 40A Nominal Voltage No. Modules 230V 230V 5 5 A A No. Poles 2 2 Add-on Restart Rm for Circuit Breakers Complete unit comprises Add-on Restart + 2-Pole or 1P+N MCB. Suitable for use with compact and standard MCBs. Description Code No. of Mod GW90991 Suitable for compact (MTC) and Standard (MT) range circuit breakers 2 mounted on side of CB. Suitable only for 2 Pole circuit breakers 230V supply No expensive call outs to reset a circuit breaker! Restart Rm checks for both earth fault and short circuit before reclosing circuit breaker 115s after tripping. Not suitable for use with 3 or 4 Pole MCBs. Add-on Restart Rd for SD earth leakage relays with or without overload protection Code Description No. of Mod GW90971 Suitable for SD E.L.R. 2 Pole 2 Build your own Restart Earth Leakage Relay. Take GW90971 and any 2-Pole 230V (SD-Class) E.L.R. Restart Rd will only check for earth fault. Not suitable for 4-Pole E.L.R. Restart Function Rd95s Rm115s Device Locked NO System check Residual Current Device release YES Reset operation Test OK? NO NO Another release occurs within 3 minutes? No. Resets=3 Reset carried out YES YES Device Locked Rd AUTOTEST Rd Restart Type Residual current devices ● ● Automatic reset Insulation control Short-circuit control Residual current device self-test Rm Residual current devices ● ● Residual current and MT circuit breakers ● ● ● ● Add-on Restart Compatibility Compatible Circuit Breakers MTC No. Poles 1 1+N MT 2 1 1+N MTHP 2 1 MDC 2 1+N Idn (mA) MT+BD 2 30,300 1+N MTHP+BDHP SD 2 2 in 2 in 2 mod. 3 mod. all 2 all all Restart Type ● Rd Rm ● ● ● ● ● ● ● Weekly Auto Test Cycle Initial set-up & manual start of first Self-test Normal operation ● Weekly Cycle 1 Closing of bypass circuit 2 Residual Current Test 4 Re-opening of bypass circuit 3 Automatic Reset GEW Has the residual NO current circuit breaker tripped? YES Fault Indicator and alarm contact close 77 CIRCUIT BREAKERS, FUSE GEAR & ISOLATORS Restart is an exclusive and revolutionary automatic reset device for earth leakage (RCDs) and MCBs. Restart automatically restores the supply of electric power in total safety. Restart with Autotest also tests the device weekly without disconnecting the supply. No more melted freezers or dry gardens!