GLOBAL-TWIN Conforming to IEC & local Standards The G-TWIN series is a global breaker series that satisfies all major standards. IEC UL/CSA IEC 60947-2 EN North America Europe Europe EN 60947-2 North America UL489 CAN/CSA C22.2 NO.5 NEMA AB1 GB China China GB 14048.2 JIS S Japan JIS C 8201-2-1 MCCB JIS C 8201-2-2 ELCB CE model CCC model EN 60947-2 JIS C 8201-2-1 JIS C 8201-2-2 CE marking (TÜV) JIS model GB 14048.2 (China) CCC approved UL 489 CAN/CSA C22.2 NO.5 NEMA AB1 IEC 60947-2 JIS C 8201-2-1 JIS C 8201-2-2 UL mark (cUL) CE marking (TÜV) CCC model -TWIN -TWIN -TWIN JIS model -TWIN UL mark (cUL) + CE marking (TÜV) + CCC approved + JIS CE marking (TÜV) + CCC approved + JIS G-TWIN Standard series G-TWIN Global series IEC 60947-2 EN 60947-2 (CE marking) GB 14048.2 (CCC) JIS C 8201-2-1 JIS C 8201-2-2 IEC 60947-2 EN 60947-2 (CE marking) GB 14048.2 (CCC) JIS C 8201-2-1 JIS C 8201-2-2 Ampere frame size (AF) 32 50 63 FUJI Earth Leakage Circuit Breakers UL489 model CE model JIS C 8201-2-1 JIS C 8201-2-2 UL 489 CAN/CSA C22.2 NO.5 NEMA AB1 Ampere frame size (AF) 100 125 160 250 400 630 800 50 100 125 250 400 630 ETH132 Usefulness Leading the way in user-friendliness Compact & High performance Compact size meeting UL489 480V requirements & same dimensions as MCCB Unifying and reducing the types of internal accessories 32 to 100AF ELCB MCCB Rated voltage 480V (W105×H181×D68mm) Rated voltage 480V (W105×H181×D68mm) Same dimentions sInternal and external accessories A wider range of customer-mountable accessories ELCB Technical innovation Arc and gas flow control technology Effect of “ablation breaking technology” 125 to 250AF G-TWIN sSharing internal accessories of 125/160/250AF breakers. Shunt trip device Short-circuit current Auxiliary switch Decrease by Narrow slit resin s Increased arc voltage due to narrow slit effect s Increased arc voltage and highspeed moving contact opening by ablation effect s Suppression of internal pressure rise by adjusting the narrow slit width Magnetic yoke arrangement s An increase in the repulsion force of the moving contact at initiation of contact opening Alarm switch Ecology Number of types of internal accessories AF -TWIN G-TWIN 125 8 8 160/250 8 400 to 800AF Advanced environmental technology Conforming to the RoHS Directive The G-TWIN Series is designed to lower environmental impact. Moving contact Recycling s For easier recycling, all major parts are marked with the names of the materials used. Stationary Conforming to the RoHS Directive contact s Lead-free (Pb-free) solder is used. 6+ s Free of hexavalent chromium (Cr -free) (125 to 800AF) Lower environmental impact Advanced green engineering and energy-saving support Conforming to the RoHS Directive G-TWIN Standard series ELCB Compact & High performance ELCB sThe number of types of internal accessories of 400/630/800AF has been significantly reduced. GLOBAL TWIN Ecology Conforming to certifications and standards in major world markets Expanded frame sizes in G-TWIN Global Series Undervoltage trip device Auxiliary switch FUJI MCCB and ELCB Conforming to IEC & local Standards 30%! Current model Arc energy Moving contact cover s Arcing prevention at the bottom of moving contact Undervoltage trip device Shunt trip device The Twin Breakers have advanced to an entirely new stage. Alarm switch Earth Alarm switch Number of types of internal accessories AF -TWIN G-TWIN 400 630 26 6 800 G-TWIN Global series ELCB Compact models with unified dimensions meeting UL489 480V and IEC 440V requirements G-TWIN Global series ELCB GLOBAL TWIN History Usefulness ELCB Cadmium-free contact material Shunt trip device Undervoltage trip device Auxiliary switch Alarm switch 1990 TWIN Breaker 1992 Super TWIN 1995 Super 60 2001 -TWIN 2006 G-TWIN Leading the way in user-friendliness G-TWIN Standard series ELCB Fuji Electric launched the Twin Breaker Series to world markets in 1990, in which molded case circuit breaker (MCCB) and earth leakage circuit breaker (ELCB) types were unified in external dimensions for the first time in the world. The Twin Breaker Series was highly evaluated and gained strong support, and the concept of Twin Breakers was established as Japan's de facto standards for MCCBs and ELCBs. In 1992, Fuji Electric released the Super Twin Breaker Series, which enabled user installation of internal accessories for the first time in Japan. In 1995, Fuji Electric released the Super 60 Series and advanced modularization via uniform external dimensions. In 2001, Fuji Electric launched the -Twin Series to further advance the miniaturization and modularization of economic types with 100A frame or less as Japan's first multi-standard circuit breakers satisfying domestic and inter national standards. Since then, Fuji Electric has been making further product improvements by predicting market trends. In recent years, market globalization has increasingly accelerated. At the end of 2004, the Japanese Industrial Standards (JIS) were aligned with the IEC standards, and the globalization in this field has been further accelerated. Based on the Twin Breaker Series, Fuji Electric has expanded the range of its products conforming to and approved by international standards for global markets, always advanced the innovative development of fundamental technologies in response to the market demand, and developed the G-TWIN Series of MCCBs and ELCBs. 5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo 103-0011, Japan URL http://www.fujielectric.co.jp/fcs/eng/ Information in this catalog is subject to change without notice. 2010-8 PDF FOLS ETH132 Your Best Choice is FUJI. FUJI Earth Leakage Circuit Breakers G-TWIN series 32AF 50AF 63AF 100AF 125AF 250AF CNS5422(IEC/EN60947-2, GB14048.2, JISC8201-2-2) Type EW32AAG Pole 2 3 EW32EAG EW32SAG EW50AAG 3 3 2 In [A] 5, 10, 15, 20, 30, (32)*2 Rated current Rated impulse withstand voltage Uimp [kV] 2.5 Isolation compliant 4 4 Rated sensitive current [mA] 15, 30, 100 Tripping time 4 2.5 EW50RAG EW63EAG EW63SAG EW63RAG EW100AAG EW100EAG EW125JAG 3 3 3 3 3 2 3 10, 15, 20, 30, (32)*2, 60, (63)*2 40, 50 60, (63)*2, 75, 100 50, 60, (63)*2, 75, 100 15, 20, 30, 40, 50, 60, 75, 100, 125 125, 150, 160, 175, 200, 225, 250*1 4 6 6 4 4 6 6 Approved Approved Approved Approved 100-230-440 100-230 100-230 30, 100/200 30, 100/200/500 6 6 100-230-440 100-230-440 100-230 100-230-440 100-230-440 100-230-440 15, 30, 100 30, 100/200/500 15, 30, 100 15, 30, 100/200 30, 100/200/500 30, 100/200/500 [s] 0.1 0.1 Instanteneous/time delay trip type Rated sensitive current [mA] – 15, 30, 100/200 30, 100/200/500 30, 100/200/500 0.1 3 6 4*2 EW125RAG EW250EAG EW250JAG 3 3 3 4 100-230- 100-230-440 440 0.1 4*2 30 0.1 – – – – – – – – – 100/200/500/1000 changeover 100/200/500/1000 changeover [s] – – – – – – – – – – – – 0.1/0.4/1/2 changeover 0.1/0.4/1/2 changeover Inertia non-tripping time [s] – – – – – – – – – – – – 0/0.2/0.5/1 0/0.2/0.5/1 [Hz] 50-60 AC 440V 50-60 50-60 50-60 3 4 30 0.1 – Rated frequency EW250RAG 100-230-440 – Tripping time Rated breaking CNS5422 capacity IEC60947-2 Icu/Ics [kA] EN60947-2 JIS8201-2-2 EW50SAG 3 Approved Ue [V AC] 100-230 Instantaneous trip type EW50EAG 3 3, 5, 10, 15, 20, 30, 5, 10, 15, 20, 30, (32)*2, 40, 50 (32)*2 Approved Rated voltage 3 50-60 50-60 – 1.5/1 2.5/2 – 2.5/2 7.5/4 10/5 2.5/2 7.5/4 10/5 – – 10/5 30/15 50/25 18/9 30/15 50/25 240V – – – – – – – – – – – – – 50/25 100/50 36/18 50/25 100/50 230V 2.5/2 2.5/2 5/3 2.5/2 5/3 10/5 25/13 5/3 10/5 25/13 5/3 10/5 25/13 50/25 415V 400V 380V GB14048.2 Dimensions a AC 100V 2.5/2 400V – 1.5/1 2.5/2 – 2.5/2 7.5/4 10/5 2.5/2 7.5/4 10/5 – – 10/5 30/15 50/25 18/9 30/15 230V 2.5/2 2.5/2 5/3 2.5/2 5/3 10/5 25/13 5/3 10/5 25/13 5/3 10/5 25/13 50/25 100/50 36/18 50/25 75 75 50 75 75 75 75 75 75 75 75 90 105 105 100 100 100 100 100 100 100 100 100 100 100 155 165 165 [mm] a d c 50 b b 5/3 5/3 75 100 2.5/2 5/3 75 90 120 155 100/50 140 105 c 60 60 60 60 60 60 60 60 60 60 60 60 68 68 68 68 68 84 84 84 84 84 84 84 84 84 84 84 84 95 95 95 95 95 0.5 0.6 0.4 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.3 1.8 1.8 [kg] 0.4 Tripping device 0.5 0.6 Hydraulic-magnetic 1.7 1.3 1.7 140 165 d Mass *1 4-pole, 250A Breakers cannot be made. 120 2.3 1.8 2.3 Thermal-magnetic *2 Contact FUJI. G-TWIN series 400AF 630AF HG series 800AF CNS5422(IEC/EN60947-2, GB14048.2, JISC8201-2-2) CNS5422(JISC8201-2-2 50AF 100AF 225AF Ann 2) DV series JISC8221 30AF Ann 2) Type EW400EAG EW400SAG EW400RAG EW400HAG EW630EAG EW630RAG EW630HAG EW800EAG EW800RAG EW800HAG Type HG53B HG103B HG203B Type DV32 DV33 Pole 3 3 3 3 3 3 3 3 3 3 Pole 3 3 3 Pole 2 3 Rated current 4 4 In [A] 250, 300, 350, 400 Rated impulse withstand voltage 700, 800 6 6 Approved Approved 100-230-440 100-230-440 [mA] 30 – – [s] 0.1 – – 100/200/500/1000 changeover 100/200/500/1000 changeover Uimp [kV] 6 Isolation compliant Approved Rated voltage Ue [V AC] 100-230-440 Rated sensitive current Instantaneous trip type Tripping time Instanteneous/time delay trip type Rated sensitive current [mA] 100/200/500/1000 changeover 0.1/0.4/1/2 changeover 0.1/0.4/1/2 changeover [s] 0/0.2/0.5/1 0/0.2/0.5/1 0/0.2/0.5/1 AC 440V 30/15 50-60 36/18 50/25 70/35 36/18 50-60 50/25 70/35 36/18 50/25 70/35 Rated breaking capacity Icu/Ics [kA] [Hz] 50-60 CNS5422 AC IEC60947-2 EN60947-2 JIS8201-2-2 400V 380V 50/25 85/43 100/50 125/63 50/25 100/50 125/63 50/25 100/50 Dimensions a d c 100V AC 400V 230V Dimensions a d c b Mass Tripping device 65 65 Dimensions a b 400V 30/15 36/18 50/25 50/25 85/43 100/50 [mm] a 140 140 140 b 257 257 257 c 103 103 d 146 146 [kg] 5.8 5.8 5.8 Thermal-magnetic 70/35 36/18 125/63 50/25 70/35 36/18 50/25 50/25 100/50 125/63 50/25 100/50 125/63 210 210 210 210 210 257 275 275 275 275 275 275 103 103 103 103 103 103 103 103 146 146 146 146 146 146 146 146 9.1 9.1 9.1 9.6 9.6 9.6 7.8 140 5.8 185 7.8 b 70/35 210 185 240V – – – 230V 100 100 100 100V 125/63 230V GB14048.2 65 415V 380V 415V 240V 440V Ue [V AC] 100-200 Mass Tripping device [mm] a b 90 90 105 155 155 165 c 82 82 99 d 104 104 127 [kg] 2.3 2.3 3.3 Thermal-magnetic [mA] 15, 30 [s] 0.1 [Hz] 50-60 Rated short-time withstand current Icw [s] 0.1 Rated frequency Rated voltage Rated frequency Rated sensitive current [mA] 30, 100/200/500 changeover Tripping time In [A] 30 Tripping time Ue [V AC] 100-230-440 Instantaneous trip type Rated current Rated sensitive current – Rated voltage [s] 0.1/0.4/1/2 changeover 15, 20, 30, 40, 50, 1 2 5 , 1 5 0 , 1 7 5 , 60, 75, 100 200, 225 Uimp [kV] – Isolation compliant Inertia non-tripping time [Hz] 50-60 In [A] 15, 20, 30, 40, 50 Rated impulse withstand voltage Tripping time Rated frequency Rated breaking CNS5422 capacity IEC60947-2 Icu/Ics [kA] EN60947-2 JIS8201-2-2 Rated current 500, 600, 630 Mass Tripping device d c AC200V 1.5 1.5 [kA] AC100V [mm] a 68 90 b 70 80 c 40 40 d 63 [kg] 0.17 63 0.24 Ground fault protection only