1 Non-dimming/On-board Type CXA-M10M-L ■ Features ■ Applications ●1 and 2 outputs ●UL60950 approved ●Applicable panel size*: 3 to 10 inches ●Select of quantity for output and output current is possible by connection method. (Notice) Applicable panel size becomes a standard. CXA-M10M-L Specifications(Please refer to each specification before use) Electrical Characteristics CONNECTION A Item Unit Symbol Output Current mArms Iout Input Current A Frequency kHz Open Circuit Voltage Vrms Iin Freq Vopen min 9 8 23 1000 Specification typ 10 10 0.21 28 1200 max 11 12 0.33 33 - Vin(V) 24 0.24 24 1.2 24 1.2 24 1.2 24 1.2 Condition Ta(℃ ) 23 5 -10 to +60 -10 to +60 -10 to +60 -10 to +60 RL(kΩ) 40 30 to 50 30 to 50 30 to 50 ∞ min 5.0 4.4 26 1000 Specification typ 6.0 6.0 0.14 31 1200 max 6.4 7.0 0.21 36 - Vin(V) 24 0.24 24 1.2 24 1.2 24 1.2 24 1.2 Condition Ta(℃ ) 23 5 -10 to +60 -10 to +60 -10 to +60 -10 to +60 RL(kΩ) 67 50 to 84 50 to 84 50 to 84 ∞ min 4.3 3.8 23 1000 Specification typ 5.0 5.0 0.12 28 1200 max 5.5 6.0 0.19 33 - Vin(V) 24 0.24 24 1.2 24 1.2 24 1.2 24 1.2 Condition Ta(℃ ) 23 5 -10 to +60 -10 to +60 -10 to +60 -10 to +60 RL(kΩ) 80 60 to 100 60 to 100 60 to 100 ∞ min 4.5 4.0 23 1000 Specification typ 5.0 5.0 0.21 28 1200 max 5.5 6.0 0.33 33 - Vin(V) 24 0.24 24 1.2 24 1.2 24 1.2 24 1.2 Condition Ta(℃ ) 23 5 -10 to +60 -10 to +60 -10 to +60 -10 to +60 RL(kΩ) 80 60 to 100 60 to 100 60 to 100 ∞ Remark Open load CONNECTION B Item Unit Symbol Output Current mArms Iout Input Current A Frequency kHz Open Circuit Voltage Vrms Iin Freq Vopen Remark Open load CONNECTION C Item Unit Symbol Output Current mArms Iout Input Current A Frequency kHz Open Circuit Voltage Vrms Iin Freq Vopen Remark Open load CONNECTION AD Item Unit Symbol Output Current mArms Iout Input Current A Frequency kHz Open Circuit Voltage Vrms Iin Freq Vopen Remark Open load Other Specifications Dimming Function Operating Temperature Storage Temperature Operating Humidity Ratio Safety Standard Weight Dimensions(WxDxH) Fused Input Remote ON / OFF Alarm Signal Function Shutdown Function ℃ ℃ RH% g mm Silicone Coating on High Voltage Area No -10 to +60 -20 to +85 95Max UL60950 21 56x29x16.5 (*1) No No No No ■ Conformity to RoHs Directive This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. No (*1) These dimensions are indicated the maximum. Length of input-output terminal pin is not included. All specifications are subject to change without notice. 001-01/20080228/etl_cxa_m10m_l 2 CXA-M10M-L Outline Drawing Example of label marking Product name, Lot No., Country of origin, TDK-Lambda logotype, UL standard marking H5910 R Tinning hard-drawn copper wire (30) High-voltage generator ※ (The entire surface within a range of 30mm away from the end of the basein) ※From high-voltage generator, please secure space distance more than 2mm in top and bottom right and left. unit:mm Terminal Numbers And Functions Terminal number Symbol Rated voltage ① Vin 24V ② GND 0V ③ OUT1 300Vrms ④ OUT2 300Vrms ⑤ OUT GND 0V ・All specifications are subject to change without notice. 3 CXA-M10M-L Connections CONNECTION A 24V Shunting in OUT1 and OUT2 CONNECTION B 24V Open OUT1 or OUT2 CONNECTION C 24V Shunting in OUT2 and OUT - GND CONNECTION D 24V RL:Load resistance(7W minimum) All specifications are subject to change without notice.