CXA-M10M-L - TDK

advertisement
1
Non-dimming/On-board Type
CXA-M10M-L
■ Features
■ Applications
●1 and 2 outputs
●UL60950 approved
●Applicable panel size*: 3 to 10 inches
●Select of quantity for output and output current is
possible by connection method.
(Notice) Applicable panel size becomes a standard.
CXA-M10M-L Specifications(Please refer to each specification before use)
Electrical Characteristics
CONNECTION A
Item
Unit
Symbol
Output Current mArms Iout
Input Current
A
Frequency
kHz
Open Circuit Voltage Vrms
Iin
Freq
Vopen
min
9
8
23
1000
Specification
typ
10
10
0.21
28
1200
max
11
12
0.33
33
-
Vin(V)
24 0.24
24 1.2
24 1.2
24 1.2
24 1.2
Condition
Ta(℃ )
23 5
-10 to +60
-10 to +60
-10 to +60
-10 to +60
RL(kΩ)
40
30 to 50
30 to 50
30 to 50
∞
min
5.0
4.4
26
1000
Specification
typ
6.0
6.0
0.14
31
1200
max
6.4
7.0
0.21
36
-
Vin(V)
24 0.24
24 1.2
24 1.2
24 1.2
24 1.2
Condition
Ta(℃ )
23 5
-10 to +60
-10 to +60
-10 to +60
-10 to +60
RL(kΩ)
67
50 to 84
50 to 84
50 to 84
∞
min
4.3
3.8
23
1000
Specification
typ
5.0
5.0
0.12
28
1200
max
5.5
6.0
0.19
33
-
Vin(V)
24 0.24
24 1.2
24 1.2
24 1.2
24 1.2
Condition
Ta(℃ )
23 5
-10 to +60
-10 to +60
-10 to +60
-10 to +60
RL(kΩ)
80
60 to 100
60 to 100
60 to 100
∞
min
4.5
4.0
23
1000
Specification
typ
5.0
5.0
0.21
28
1200
max
5.5
6.0
0.33
33
-
Vin(V)
24 0.24
24 1.2
24 1.2
24 1.2
24 1.2
Condition
Ta(℃ )
23 5
-10 to +60
-10 to +60
-10 to +60
-10 to +60
RL(kΩ)
80
60 to 100
60 to 100
60 to 100
∞
Remark
Open load
CONNECTION B
Item
Unit
Symbol
Output Current mArms Iout
Input Current
A
Frequency
kHz
Open Circuit Voltage Vrms
Iin
Freq
Vopen
Remark
Open load
CONNECTION C
Item
Unit
Symbol
Output Current mArms Iout
Input Current
A
Frequency
kHz
Open Circuit Voltage Vrms
Iin
Freq
Vopen
Remark
Open load
CONNECTION AD
Item
Unit
Symbol
Output Current mArms Iout
Input Current
A
Frequency
kHz
Open Circuit Voltage Vrms
Iin
Freq
Vopen
Remark
Open load
Other Specifications
Dimming Function
Operating Temperature
Storage Temperature
Operating Humidity Ratio
Safety Standard
Weight
Dimensions(WxDxH)
Fused Input
Remote ON / OFF
Alarm Signal Function
Shutdown Function
℃
℃
RH%
g
mm
Silicone Coating on
High Voltage Area
No
-10 to +60
-20 to +85
95Max
UL60950
21
56x29x16.5 (*1)
No
No
No
No
■ Conformity to RoHs Directive
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
No
(*1) These dimensions are indicated the maximum. Length of input-output terminal pin is not included.
All specifications are subject to change without notice.
001-01/20080228/etl_cxa_m10m_l
2
CXA-M10M-L
Outline Drawing
Example of label marking
Product name, Lot No., Country of origin,
TDK-Lambda logotype, UL standard marking
H5910 R
Tinning hard-drawn copper wire
(30)
High-voltage generator ※
(The entire surface within a range of 30mm
away from the end of the basein)
※From high-voltage generator, please secure space distance
more than 2mm in top and bottom right and left.
unit:mm
Terminal Numbers And Functions
Terminal
number
Symbol
Rated voltage
①
Vin
24V
②
GND
0V
③
OUT1
300Vrms
④
OUT2
300Vrms
⑤
OUT GND
0V
・All specifications are subject to change without notice.
3
CXA-M10M-L
Connections
CONNECTION A
24V
Shunting in OUT1 and OUT2
CONNECTION B
24V
Open OUT1 or OUT2
CONNECTION C
24V
Shunting in OUT2 and OUT - GND
CONNECTION D
24V
RL:Load resistance(7W minimum)
All specifications are subject to change without notice.
Download