Pressure gauge

advertisement
Pressure gauge
stainless steel vibration damped movement
ATEX-design case dim 100 mm
Application
Design
ATEX per 94/9/EC
Ex II 2 GD c TX
E 02.08.08
Ed.16.01
Pressure gauge in stainless steel version with
vibration damped movement. Suitable for aggressive media and environments. ATEX-design per 94/9/EC
EN 837-1 ATEX
Series2890
WIKA model
232.50.100 ATEX
Case size
Nominal size dim 100 mm
Accuracy
Class 1,0%
Case
Window
Stainless steel with bayonet ring
pressure relief on back of case
Pressure element
Stainless steel 316L
Movement
Stainless steel, vibration damped
Dial
Pressure unit
Aluminium, white with serial number
Marked with CE Ex II 2 GD c TX
Pressure connection
G 3/8”, G 1/2” or 1/2”NPT male
Mounting
Lower mount, also with back flange or
front flange Label
Ingress protection Label on case with modell number 232.50.100
IP 65 acc.to EN 60529/IEC 529
Ex ATEX
Ex-design per ATEX Ex II 2 GD c TX
Operating instructions
Operation instructions in english
Laminated safety glass
Bar
Pressure range
0-0,6 bar
0-1 bar
0-1,6 bar
0-2,5 bar
0-4 bar
0-6 bar
0-10 bar
0-16 bar
0-25 bar
0-40 bar
0-60 bar
0-100 bar
0-160 bar
0-250 bar
0-400 bar
0-600 bar
-
-1/0 bar
-1/1,5 bar
-1/3 bar
-1/5 bar
-1/9 bar
-1/15 bar
0-1000 bar
2890
Lower mount
2895
Lower mount
back flange
AB Svenska Industri Instrument SINI
Head office
Bransch office
2899
Lower mount
front flange
Visiting address
Box 8923, SE-402 73 Göteborg Exportgatan 38 D
Box 1208, SE-751 42 Uppsala Suttungsgränd 3
Telephone
TelefaxInternet
+46 31 7425600 +46 31 7425601 www.sini.se
+46 18 100033 +46 18 100044 mail: info@sini.se
Pressure gauge
stainless steel vibration damped movement
ATEX-design case dim 100 mm
Max permissible error 1,0%
The accuracy is expressed as a percentage of full scale range.
Permissible error 1,0% will cover 0% till 100% of scale range
with a reference temperature of +20°C.
Ex. Pressure range 0-10 bar has an error of + 0,1 bar
Temperature effect
Temperature of the measuring system over or under the
reference temperature +20°C will effect the accuracy with
0,4 percentage per +10°C. With a medium temperature
of +40°C the accuracy will be + 1,8%.
ATEX per 94/9/EC
Ex II 2 GD c TX
E 02.08.08
Pressure limitation
Full scale value by steady pressure
90% of full scale value by fluctuating pressure
By short time pressure 1,3 x of full scale value
Certificates
Certificate can be delivered as options
Inspection certificate wetted parts EN 10204-2.2
Inspection certificate wetted parts EN 10204-3.1
Calibration certificate with 3 measuring points
Calibration certificate with 5 measuring points
Permissible medium temperature
Temperature class
Max medium temperature
T 6 (+85°C < T < +85°C)
+70°C
T 5 (+100°C < T < +135°C)
+85°C
T 4 (+135°C < T < +200°C)
+120°C
T 3 (+200°C < T < +300°C)
+185°C
T 2 (+300°C < T < +450°C)
+200°C
T 1 (T > +450°C)
+200°C
Scale interval and divisions
Pressure range
Interval
Divisions
Pressure range
Interval
Divisions
Pressure gauge Cl.1,0%
Nominal size 100 and 160 mm
0-0,6 bar
0,01
60
0-160 bar
5,0
32
AB Svenska Industri Instrument SINI
Head office
Bransch office
0-1 bar
0,02
50
0-250 bar
5,0
50
0-1,6 bar
0,05
32
0-400 bar
10,0
40
0-2,5 bar
0,05
50
0-600 bar
10,0
60
0-4 bar
0,1
40
0-1000 bar
20,0
50
0-6 bar
0,1
60
-1/0 bar
0,02
50
0-10 bar
0,2
50
-1/+1,5 bar
0,05
50
0-16 bar
0,5
32
-1/+3 bar
0,1
40
0-25 bar
0,5
50
-1/+5 bar
0,1
60
0-40 bar
1,0
40
-1/+9 bar
0,2
50
0-60 bar
1,0
60
-1/+15 bar
0,5
32
0-100 bar
2,0
50
-1/+24 bar
0,5
50
Visiting address
Box 8923, SE-402 73 Göteborg Exportgatan 38 D
Box 1208, SE-751 42 Uppsala Suttungsgränd 3
Telephone
TelefaxInternet
+46 31 7425600 +46 31 7425601 www.sini.se
+46 18 100033 +46 18 100044 mail: info@sini.se
Pressure gauge
stainless steel vibration damped movement
ATEX-design case dim 100 mm
E 02.08.08
ATEX per 94/9/EC
Ex II 2 GD c TX
Code number
case dim 100 mm
unit Bar
2890
2890
2890
2895
2895
2895
Mounting
Lower
Lower
Lower
Back flange
Back flange
Back flange
Connection
G3/8”
G1/2”
1/2”NPT
G3/8”
G1/2”
1/2”NPT
0-0,6 bar
28904001
x
x
28954001
x
x
0-1 bar
28904002
x
x
28954002
x
x
0-1,6 bar
x
x
x
x
x
x
0-2,5 bar
28904004
28904404
x
28954004
28954404
x
0-4 bar
28904006
28904406
x
28954006
28954406
x
0-6 bar
28904007
28904407
x
28954007
28954407
x
0-10 bar
28904008
28904408
x
28954008
28954408
x
0-16 bar
28904011
28904411
x
28954011
28954411
x
0-25 bar
28904013
28904413
x
28954013
28954413
x
0-40 bar
28804015
28904415
x
28954015
28954415
x
0-60 bar
28904017
28904417
x
28954017
28954417
x
0-100 bar
28904019
28904419
x
28954019
28954419
x
0-160 bar
x
x
x
x
x
x
0-250 bar
x
x
x
x
x
x
0-400 bar
x
x
x
x
x
x
0-600 bar
x
x
x
x
x
x
-1/0 bar
x
x
x
x
x
x
-1/+1,5 bar
28904066
28904466
x
28954066
28954466
x
-1/+3 bar
28904067
28904467
x
28954067
28954467
x
-1/+5 bar
28904068
28904468
x
28954068
28954468
x
-1/+9 bar
28904069
28904469
x
28954069
28954469
x
-1/+15 bar
28904071
28904471
x
28954071
28954471
x
-1/+24 bar
x
x
x
x
x
x
AB Svenska Industri Instrument SINI
Head office
Bransch office
Visiting address
Box 8923, SE-402 73 Göteborg Exportgatan 38 D
Box 1208, SE-751 42 Uppsala Suttungsgränd 3
Telephone
TelefaxInternet
+46 31 7425600 +46 31 7425601 www.sini.se
+46 18 100033 +46 18 100044 mail: info@sini.se
Pressure gauge
stainless steel vibration damped movement
ATEX-design case dim 100 mm
ATEX per 94/9/EC
Ex II 2 GD c TX
Type 2890
E 02.08.08
Type 2891
Type 2895
Type 2897
Type 2898
Dim Øa
b b1b2D1D2
x1
x2
g
h±1
f
10015,549,5 83 53,5101 99 116 132 4,8 87 30
160 15,5 49,51)
1)
831)
53,5
161
159
178196 5,8 118
c
kg
8 0,6
Head office
Bransch office
Visiting address
Box 8923, SE-402 73 Göteborg Exportgatan 38 D
Box 1208, SE-751 42 Uppsala Suttungsgränd 3
G3/8-G1/2-1/2NPT
50 101,1 G3/8-G1/2-1/2NPT
From 100 bar b = 65,5 mm and b1= 99 mm
AB Svenska Industri Instrument SINI
G
Telephone
TelefaxInternet
+46 31 7425600 +46 31 7425601 www.sini.se
+46 18 100033 +46 18 100044 mail: info@sini.se
Download