Distributed by: www.Jameco.com ✦ 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Jameco Part Number 1772601 Bussmann® Panel-Mount Fuseholder with Screw-type Knob HPF Series For ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses Dimensional Data All dimensions (%0.015) With Fuse 2.81" Max. E SE F USE FU (71.4mm) 1.00" 1.31" .250" ± .003" (6.35 ± .08mm) (Typ. 2) 1.78" (25.4mm) (33.3mm) (45.2mm) FUS 0.88" 0.180" DIA. 1.125" (22.2mm) (4.6mm) 2.69" Max. (28.6mm) (68.3mm) Without Fuse Catalog Symbol: HPF, HPF-C, HPF-L, HPF-EE, HPF-JJ, HPF-FF, HPF-RR, and HPF-WT Panel-Mount Agency Information: UL Recognized, Guide IZLT2, File E14853 CSA Certified, Class 6225-01, File 47235 Flammability Rating: UL 94 HB Mounting Hole Flange Rear of Panel Mounting Hole Flange Front of Panel 1.031" + 0.003" (26.2mm + 0.08mm) 0.187" + 0.002" (4.75mm + 0.05mm) 1.312" + 0.003" 0.890" + 0.003" (33.3mm + 0.08mm) (22.6mm + 0.08mm) 1.312" + 0.003" (33.3mm + 0.08mm) Maximum panel thickness, mounting flange in front of panel Electrical Ratings Catalog Symbol HPF Amps 30(3) Volts AC HPF-C 30(4) 600 600(4) HPF-L 5 600 Fuse Description 1⁄Ω™∑ (38.1mm). 1⁄Ω™∑ (38.1mm) clear knob. BBS,⁄‹Ω£™∑ ≈ 1‹Ω•∑ fuses. HPF-EE 15 600 SC 0-15, ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ fuses. HPF-JJ 20 600 HPF-FF(2) 30(3) 30(3) 480 SC 20, ⁄‹Ω£™∑ ≈ 1⁄‹Ω£™∑ fuses. SC 25 & 30, ⁄‹Ω£™∑ ≈ 1fiΩ•∑ fuses. 600 KTK-R, LP-CC & FNQ-R Class CC fuses. HPF-RR HPF-WT 30(3) 600 Splash-proof knob. (2)No CSA Certification (3)20A max. when used with quick connect terminals. (4)HPF-C ratings for CSA - 15A, 250V. Assumes Pollution Degree 3 per UL 840: Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation that is expected. Maximum panel thickness not including any sealing gaskets. System Voltage Fuseholder HPF 600V 480 277 240 120 mm Inches mm Inches mm Inches mm Inches mm Inches 0.61 1/32” 1.50 1/32” 5.77 7/32” 6.32 7/32” 7.80 9/32” Thicker panels may be used if fuse holder load terminal is fully insulated, using a UL recognized (VW-1) insulative heat-shrink tubing, or if anticipated environment is of Pollution Degree 1 or 2, or if panel is nonconductive. Pollution Degree 2- Normally, only nonconductive pollution. However, a temporary conductivity caused by condensation may be expected. Pollution Degree 1- No pollution or only dry, nonconductive pollution. The pollution has no influence. Maximum panel thickness, mounting flange behind the panel: 5.08mm/0.200” (flush to knob collar) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. General Information: • Screw-type knob. • One-piece side terminal and threaded insert eliminates twopiece solder fabrication. • Combination ⁄Ω¢∑ quick-connect/solder terminals for versatility. • The HPF series functionally replaces the Buss® HPC series. • Replacement knob-BK/9789-⁄Ω™ (for HPF, HPF-L, HPF-EE, HPF-JJ, HPF-FF and HPF-RR). • The HPF-EE, -RR, -FF, and -JJ are UL Recognized for branch circuit protection. • Do not put tension on line (rear) terminal. The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 6-3-04 SB04184 Form No. HPF Series Page 1 of 1 Data Sheet: 2114