DC Motor Control for Phantom and Orbiter by Draper
Electrical Specifications—DC Motor Control
Caution
Input:
① Make sure electrical supply has been disconnected before attempting
to connect Lift to electricity.
② Unit operates on 12V DC.
③ Lift must be installed in accordance with the requirements of the Local
Building Codes, the Canadian Electrical Code (CEC), CAN/CSA C22.1
and the National Electric Code(NEC), NFPA 70. All operating switches
should be “off” before power is connected.
④ Lift should be operated and checked prior to installing projector.
⑤ Unit must be installed by qualified personnel.
DC Voltage 11.5-36VDC
Output:
Same voltage as input, 7.0 FLA Max. Signal output is Class 2.
Make sure the total FLA of all motors connected together does not exceed
the load carrying capacity of the this control. This device has not been
evaluated for reliability to the Standard for Tests for Safety-Related Controls
Employing Solid-State Devices, UL 991 and therefore not considered suitable
for entrapment protection.
DC Motor Control Wiring Diagram for Phantom
(-)
DC CONVERTER
BL
BL
OUTPUT: 24 VDC
2.1 Amp
(+)
BN
BN
LINEAR ACTUATOR
24 VDC
AUX PORT- For connecting multiple
controls together (up to six totalconnect from AUX to Eye).
DC Motor Control
Mounting Box
(included)
Black wire with white type
DC Motor Control
EYE PORT- For IR EYE; RF Receiver or LED
Switch. If more than one of these three is
used with control, a splitter is required.
DASHED LINES INDICATE
WIRES PROVIDED
BY INSTALLER
DOWN - BLACK
COM - WHITE
UP - RED
STOP
25/8"
WALL SWITCH
3 BUTTON
DC Motor Control Wiring Diagram for Orbiter
D2
LS2
D1
15/16"
LS1
BL
BL
BN
BN
(-)
(+)
WH
24 VDC MOTOR
DC CONVERTER
OUTPUT: 12 VDC
1.25-1.5 Amp
Black wire with white type
AUX PORT- For connecting multiple
controls together (up to six totalconnect from AUX to Eye).
DASHED LINES INDICATE
WIRES PROVIDED
BY INSTALLER
DC Motor Control
EYE PORT- For IR EYE; RF Receiver or LED
Switch. If more than one of these three is
used with control, a splitter is required.
DOWN - BLACK
COM - WHITE
UP - RED
STOP
WALL SWITCH
3 BUTTON
Spring-Loaded Terminals
When running wires to the spring-loaded terminals, use the following steps:
➀ Strip outer wire sheathing back 1", then strip
insulation of individual wires back 3/8".
➁ Place screwdriver into the top slot to open the
spring-loaded terminal.
➂ Slide wire into terminal connection point.
➃ Remove screwdriver. Wire is now locked into place.
RS232 Note:
Operating a Phantom or Orbiter via RS232 requires an R2D7. See
separate R2D7 RS232 instructions for details.
Please Note:
Cable used to connect to the Eye jack must be electrically straight
6-conductor modular cable (RJ25). This means colors do not cross
over: blue leads to blue, green to green, etc. (see diagram below).
PIN 6
CORRECT
Tab facing away (down)
BLUE
YELLOW
GREEN
RED
BLACK
WHITE
PIN 1
WHITE
BLACK
RED
GREEN
YELLOW
BLUE
Tab facing away (down) PIN 6
PIN 1
INCORRECT
R2D7
Tech
7 v2simple
de
R2D
y ma
nolog
DC
Motor
Control
Eye
Port
Prog
Light
3½"
PIN 6
RS232
Adapter
SYS 4
SYS 53 RS-232
SYS 6
SYS 71 SYS 2 SYS
SYS N
MAI
To
PC
2
7 vsimple
R2gyDmade
nolo
h
Tec
SYS 6
SYS 71 SYS 2
SYS
MAIN
®
Copyright ©2012 Draper Inc. Form DCMotorControl_TechDataSheet12 Printer in U.S.A.
Tab facing away (down)
PIN 1
WHITE
BLACK
RED
GREEN
YELLOW
BLUE
WHITE
BLACK
RED
GREEN
YELLOW
BLUE
Tab facing away (down) PIN 6
PIN 1
COLOR
WHITE
BLA
L CK
RED
GREEN
YELLOW
BLUE
PIN #
1
2
3
4
5
6
FUNCTION
R CLOCK
RQ
COMMON
+5VDC
5VDC
R DA
RQ
D TA
RP DA
D TA
+12VDC
12VDC
If you encounter any difficulties installing the DC Motor Control, call your dealer
or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.