Industry’s First Modular Fuse Blocks Simplify Design and Enhance Safety Class R, H(K), & J Fuse Applications up to 600 Amps Protection made simple ™ Knifeblade Fuse Blocks with IP20 Finger-Safe Covers Cooper Bussmann knifeblade fuse blocks offer a set of advantages you can’t find anywhere else. Modularity The only snap-together design on the market permits assembly of required poles at point-of-use. Factory assembled two- and three-pole configurations are also available. Best Ratings All fuse blocks meet UL creep and clearance requirements for Industrial Control Circuits (UL 508, UL 845). 200 Amp and above blocks meet the higher UL Industrial Power Distribution Standards (UL 98, UL 67, UL 489, UL 891, and UL 869A). Ease-of-Use Optional high-clarity, see-through finger-safe covers with test probe holes make routine maintenance activities easy. No need to open the cover to inspect wire terminations or to take thermography measurements. Available with any Class J, H(K) or R fuse block. Safety For added safety and convenience, only Cooper Bussmann offers optional IP20 finger-safe covers across the entire knifeblade fuse block range. Built-in lockout/ tagout feature improves safety. Blown fuse indication option on fuse cover assists in troubleshooting, while standard phase barriers between poles enhance safety. ™ and ™ Service In stock for QuikShip Everyday Service - 90% of orders ship within 24 hours. QuikShip Emergency Service ensures availability 24/7, 365 with “Next flight out” courier service. Knifeblade Fuse Block Features & Specifications Features and Benefits • Integral dovetails allow snapping together multiple poles at point-of-use for greater application flexibility • Factory assembled two- and three-pole configurations available • Up to four mounting holes per pole increase installation flexibility • Standard phase barriers between poles for additional safety • Design meets UL creep and clearance requirements for Industrial Control Circuits (UL 508 and UL 845) • 200 to 600A blocks meet the higher UL creep and clearance requirements for Industrial Power Distribution Standards (UL 98, UL 69, UL 489, UL 891 and UL 869A) • Optional IP20 finger-safe covers available on entire knifeblade fuse block product line: – High-clarity see-through covers allow for inspecting wire terminations or thermography measurements without removing cover – Probe holes included for easy, safer testing and troubleshooting – Built-in lockout/tagout feature improves safety • Standard fuse clip reinforcing springs enhance electrical contact Specifications Agency Information: Blocks UL - Listed cULus E14853 – IZLT & IZLT7 CSA - Certified 47235 – 6225-01 Covers UL - Listed UL E58836 – JDVS2 CSA - Certified 47235 – 6225-01 Ratings: Volts: 250V, 600V Amps: 70-600A SCCR: 200kA (Class R & J) 10kA (Class H & K) Flammability Ratings: Blocks UL 94V0, self-extinguishing Covers UL 94HB, self-extinguishing Operating & Storage Temperature Range: Blocks -40ºC to 120ºC Covers Non-indicating covers -40ºC to 120ºC Indicating covers -20ºC to 90ºC Materials: Base – Thermoplastic Box Lug – Tin-plated aluminum Wire:* Cu/Al – 75ºC/90ºC (100 - 200A) Cu/Al – 75ºC only (400 - 600A) *Higher temperature rated wire can be used with appropriate derating. Knifeblade Fuse Block Feature Highlights Features Optional SeeThrough, Snap-on Cover for Easy Visual Inspection* Vent Slots Improve Cooling Optional Blown Fuse Indication Speeds Troubleshooting • • Lockout/Tagout Feature Improves Safety Probe Holes for Easy Testing Without Removing Cover • • Finger Grips on Cover for Easy Removal • • • • • • Standard Phase Barriers for Additional Safety Multiple Mounting Holes for Each Pole Provide Flexible, Secure Mounting Toolless Interlocking Modular Design for Easy Point-of-Use Assembly Finger-Safe Wire Entry with Cutout Tabs for Larger Wires • 600A Version (with double box lug for easier wiring with smaller, dual conductors) *No fuse derating necessary. Knifeblade Fuse Block Part Number Table 250V Class R & H(K) Catalog Number Class H(K) Class R 600V Class R & H(K) Covers* w/o Indication w/ Indication Volts Fuse Range Number (amps) of Poles HM25100-1CR RM25100-1CR HM25100-2CR RM25100-2CR 1 70100 CVR-RH-25100 CVRI-RH-25100 HM25100-3CR RM25100-3CR HM25200-1CR RM25200-1CR HM25200-2CR RM25200-2CR HM25200-3CR RM25200-3CR 2 3 CVR-RH-25200 CVRI-RH-25200 250 110200 HM25400-1CR RM25400-1CR 1 2 3 1 225400 2 HM25400-3CR RM25400-3CR 3 HM25600-1CR RM25600-1CR HM25600-2CR RM25600-2CR HM25600-3CR RM25600-3CR CVR-RH-25600 CVRI-RH-25600 450600 1 2 3 CVR-RH-60100 CVRI-RH-60100 70100 HM25400-2CR RM25400-2CR CVR-RH-25400 CVRI-RH-25400 HM60100-1CR RM60100-1CR HM60100-2CR RM60100-2CR 1 HM60100-3CR RM60100-3CR HM60200-1CR RM60200-1CR HM60200-2CR RM60200-2CR HM60200-3CR RM60200-3CR CVR-RH-60200 CVRI-RH-60200 600 110200 HM60400-1CR RM60400-1CR HM60400-2CR RM60400-2CR 225400 CVR-RH-60400 CVRI-RH-60400 HM60400-3CR RM60400-3CR HM60600-1CR RM60600-1CR HM60600-2CR RM60600-2CR HM60600-3CR RM60600-3CR 450600 CVR-RH-60600 CVRI-RH-60600 Volts Fuse Range (amps) JM60100-1CR 70100 CVRI-J-60100 JM60100-3CR JM60200-1CR JM60200-2CR JM60200-3CR JM60400-1CR Number of Poles 1 CVR-J-60100 2 3 CVR-J-60200 CVRI-J-60200 600 110200 1 2 3 1 225400 2 JM60400-3CR 3 JM60600-1CR JM60600-2CR JM60600-3CR 450600 1 2 3 JM60400-2CR CVR-J-60400 CVR-J-60600 CVRI-J-60400 CVRI-J-60600 *Covers sold serarately. Blown fuse indication requires 90 volts minimum and closed circuit to operate. **With easyID™ blown fuse indication. 1 2 3 1 2 3 Catalog Number Covers* Class J w/o Indication w/ Indication JM60100-2CR 2 3 1 2 3 Class J Wire Range 1/0-3 AWG 4-6 AWG 8 AWG 10-14 AWG 250 MCM-1 AWG 2-6 AWG Torque N•m (Lb-in) 5.6 (50) 5.1 (45) 4.5 (40) 4.0 (35) 42 (375) 31 (275) 600kcmil 500kcmil-4 AWG Cu Dual 3/0 - 4 AWG Al Dual 3/0 - 4 AWG 57 (500) 51 (450) 57 (500) 34 (300) (2) 500kcmil-4 AWG 51 (450) 1/0-3 AWG 4-6 AWG 8 AWG 10-14 AWG 250 MCM-1 AWG 2-6 AWG 5.6 (50) 5.1 (45) 4.5 (40) 4.0 (35) 42 (375) 31 (275) 600kcmil 500kcmil-4 AWG Cu Dual 3/0 - 4 AWG Al Dual 3/0 - 4 AWG 57 (500) 51 (450) 57 (500) 34 (300) (2) 500kcmil-4 AWG 51 (450) Wire Range 1/0-3 AWG 4-6 AWG 8 AWG 10-14 AWG Torque N•m (Lb-in) 5.6 (50) 5.1 (45) 4.5 (40) 4.0 (35) 250 MCM-1 AWG 2-6 AWG 42 (375) 31 (275) 600kcmil 500kcmil-4 AWG Cu Dual 3/0 - 4 AWG Al Dual 3/0 - 4 AWG 57 (500) 51 (450) 57 (500) 34 (300) (2) 500kcmil-4 AWG 51 (450) Cooper Bussmann Fuses Class H(K): NON Class R: LPN-RK_SP LPN-RK_SPI** FRN-R KTN-R Class H(K): NOS Class R: LPS-RK_SP LPS-RK_SPI** FRS-R KTS-R KWS-R PVS-R Cooper Bussmann Fuses LPJ_SP LPJ_SPI** JKS DFJ 250V Class R & H(K) Dimensional Specifications Dimensions - mm (in) 153.15 6.030 55.28 2.176 51.05 2.010 70.12 2.761 183.61 7.229 170.74 6.722 60.97 2.401 70-100A 102.10 4.020 71.86 2.829 71.86 2.829 110-200A 135.60 5.338 67.80 2.669 93.69 3.689 75.38 2.968 206.83 8.143 67.54 2.659 221.36 8.715 203.40 8.008 95.98 3.779 95.98 3.779 225-400A 184.92 7.280 92.46 3.640 104.52 4.115 116.14 4.573 257.64 10.143 240.71 9.477 79.89 3.145 277.38 10.920 121.10 4.768 121.10 4.768 450-600A 125.12 4.926 151.25 5.955 151.25 5.955 306.74 12.076 250.24 9.852 289.30 11.390 106.98 4.212 375.36 14.778 134.67 5.302 For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks 141.12 5.556 600V Class R & H(K) Dimensional Specifications 153.15 6.030 Dimensions - mm (in) 102.10 4.020 51.05 2.010 55.28 2.176 71.86 2.829 221.80 8.732 112.03 4.411 234.44 9.230 70-100A 71.86 2.829 110-200A 133.66 5.262 66.83 2.631 91.69 3.610 75.38 2.968 270.65 10.656 131.35 5.171 284.86 11.215 200.49 7.893 70.12 2.761 95.98 3.779 95.98 3.779 225-400A 184.92 7.280 92.46 3.640 104.52 4.115 116.22 4.576 317.29 12.492 156.47 6.160 334.21 13.158 277.38 10.920 121.10 4.768 121.10 4.768 450-600A 250.24 9.852 125.12 4.926 151.25 5.955 151.25 5.955 383.16 15.085 365.88 14.405 183.56 7.227 375.36 14.778 134.67 5.302 For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks 141.82 5.583 Class J Dimensional Specifications Dimensions - mm (in) 153.15 6.030 102.10 4.020 55.28 2.176 51.05 2.010 71.86 2.829 221.80 8.732 112.03 4.411 234.44 9.230 70-100A 71.86 2.829 110-200A 133.66 5.262 91.69 3.610 75.38 2.968 66.83 2.631 270.65 10.656 131.35 5.171 284.86 11.215 200.49 7.893 70.12 2.761 95.98 3.779 95.98 3.779 225-400A 184.92 7.280 92.46 3.640 104.52 4.115 116.22 4.576 317.29 12.492 156.47 6.160 334.21 13.158 277.38 10.920 121.10 4.768 121.10 4.768 450-600A 250.24 9.852 125.12 4.926 151.25 5.955 151.25 5.955 383.16 15.085 365.88 14.405 183.56 7.227 375.36 14.778 134.67 5.302 For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks 141.82 5.583 Broadest Range of Modular Finger-Safe Knifeblade Fuse Blocks More Cooper Bussmann Fuse Blocks and Holders Modular Knifeblade Fuse Blocks with Finger-safe Covers UL, IEC & PV CH Modular Fuse Holder Series Open Design Knifeblade Series CUBEFuse™ Holder Series IEC CH Fuse Holder Series Open Design Knifeblade Series Class J CH Fuse Holder Series In-line Fuse Holder Series Class J JTN 600 Fuse Holder Series Panel Mount Fuse Holder Series Optima® Midget & Class CC Series SAMI™ Fuse Covers Series Open Design Class CC & Midget Series Military Fuse Holder Series Customer Assistance Available to answer questions regarding Cooper Bussmann products & services Monday-Friday, 8:00 a.m. – 6:00 p.m. Central Time. Contact: Application Engineering Technical assistance is available to all customers. Application support is available Monday-Friday, 8:00 a.m. – 5:00 p.m. Central Time. Contact: • Toll-free phone: 855-287-7626 (855-BUSSMANN) • Toll-free fax: 800-544-2570 • E-mail: busscustsat@cooperindustries.com • Toll-free phone: 855-287-7626 (855-BUSSMANN) • E-mail: fusetech@cooperindustries.com • Live Chat: www.cooperbussmann.com Emergency and After-Hours Orders Next flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, & modest emergency service fee. Place these orders through the Customer Satisfaction Team during regular business hours. For after-hours, contact: Online Resources Visit www.cooperbussmann.com for the following resources: Customer Satisfaction Team • Product search & cross-reference • Product & technical materials • Solutions centers for information on topical issues including arc-flash, selective coordination & short-circuit current rating • Technical tools, like our arc-flash calculator • Where to purchase Cooper Bussmann product • After hours 314-995-1342 C3 – the Enhanced, Online Cooper Customer Center Provides real time product availability, net pricing, order status & shipment tracking across six Cooper divisions: B-Line, Bussmann, Crouse-Hinds, Lighting, Power Systems & Wiring Devices. Call 877-995-5955 for log-in assistance. Available at: • www.cooperc3.com Cooper Bussmann St. Louis, MO 63178 636-394-2877 w w w. c o o p e r b u s s m a n n . c o m Your Authorized Cooper Bussmann Distributor is: Cooper Industries plc 600 Tra vis, Ste. 5600 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com Reorder # 3192 0412-2.5M Printed in USA