CGA Chillers Air-cooled scroll chillers Customer benefits Options • Designed in compliance with the directive ErP • Low ambient temperature kit (down to -10°C) 2009/125/EC • Digital Defrost is a self-adaptive defrosting system able to intervene only in case of a consistent thickness formation of ice on the coils’ fins. • Dynamic Logic Control manages the differential of • Low water temperature kit (down to -12°C) • Hydraulic module with water pump • Hydraulic module with water pump and water tank (delivered separately) • Compressors sound jackets the inlet water temperature on the basis of the speed • Soft - starter of its variation. Thanks to the DLC the number of the • Control panel electric heater with thermostat compressor starts decreases ensuring economic and • Phase failure protection relay energy savings. • Epoxy coated condensing coils • Dynamic Set Point function allows changing the setpoint simultaneously to always achieve the conditions of best Accessories comfort and maximum energy savings. • Remote control panel • Communication card RS485 Main features • Flow switch • Scroll compressor • Automatic water filling • Axial fans propeller type • Water strainer • Airside heat exchanger with seamless copper tubes and • Water gauges aluminium fins • Rubber anti-vibration mounts • Waterside heat exchanger steel brazed plate fitted with differential pressure switch and antifreeze protection Controls electric heater • Microprocessor-based controller to manage unit on/off • Low ambient condensing pressure control with variable fan speed modulation mode, operating mode setting, parameters setting, and error code display • Electrical panel with main switch • Casing and panels in galvanized and painted steel This description may not include all options and accessories available. For full technical information, visit www.trane.com/litweb or contact your local sales office. CGA Cooling capacity (2) Total power input (2) EER (2) ESEER (2) Sound power level (3) Sound pressure level (4) Number of circuit(s) Number of compressors per circuit Dimensions and weights (operating) Length Width Height Weight (5) Weight water tank Electrical data Maximum amps Start-up amps (°C) (°C) (V/Ph/Hz) -5 (-10) / +43°C -6 (-12) / 18°C 400/3+n/50 040 14.6 4.8 3.00 3.43 76 50 1 1 060 20.9 7.1 2.93 3.25 72 46 1 1 070 23.7 8.6 2.77 3.11 73 47 1 1 080 29.0 9.8 2.96 3.27 74 48 1 1 105 36.6 12.1 3.03 3.38 75 48 1 1 115 40.4 14.0 2.90 3.19 81 55 1 1 (mm) (mm) (mm) (kg) (kg) 1125 440 1444 168 70 1465 560 1448 246 96 1465 560 1448 255 96 1671 560 1687 288 135 1671 560 1687 291 135 1671 560 1687 301 135 (A) (A) 10.8 72.8 26.3 102.3 29.3 146.3 35.9 148.9 41.9 164.9 42.9 203.9 (kW) (kW) (dBA) (dBA) (1) In parentheses: With low ambient temperature option (2) At Eurovent conditions: 12/7°C entering/leaving water temperature and 35°C ambient temperature according to EN 14511 (3) At Eurovent conditions, with 1pW reference sound power, according to ISO9614 (4) Average at 10 meters in a free field. This is a non-contractual data, calculated from the above certified sound power level according to the formula Lp=Lw-10logS. This is an averaged value considering the unit as a paralelopedic box with five exposed face areas. (5) Excluding water tank Chillers Operating outdoor air temperature range (min./max.) (1) Leaving water temperature range (min./max.) (1) Power supply