covel i g h t 2 6 ™ features Low profile indirect luminaire designed for concealed cove applications. Luminaires are provided with quick connect thru–wire harness for easy installation in continuous runs. Luminaire housing length designed around specified lamp length to minimize socket shadow. Continuous run lengths may be configured with combinations of luminaire lengths up to 8'. Covelight™ provides pleasing and even illumination that highlights architectural details. dimensional data details 2.00" 50.8mm 6.00" 152.4mm thru–wire harness july 2008 A lamping options T8 LAMPS T5/T5HO LAMPS performance 1–Lamp T5HO 76.6% Efficiency 3843 cd @ 125° Visit focalpointlights.com for complete photometric data. www.focalpointlights.com | 1.773.247.9494 fixture: project: ordering details luminaire series fixture lengths t8 Covelight T5/T5HO Covelight T8 t5/t5ho 24.00" 22.40" 2' 36.00" 2" x 6" 34.30" 46.10" 4' One Lamp T8 (FCVA only) 4' 60.00" 57.90" 5' 5' 72.00" 68.50" 6' 6' 84.00" 7' 80.30" 7' 96.00" 8' 26 lamping 3' 48.00" 26 profile 2' 3' FCVM FCVA 92.10" 8' One Lamp T5 One Lamp T5HO Two Lamp T5 Two Lamp T5HO (T5 units supplied to match lamp length See Luminaire Lengths chart for more information) 1T8 1T5 1T5HO 2T5 2T5HO circuit Single Circuit Dual Circuit (Two lamps only) 1C 2C voltage 120 Volt 277 Volt 347 Volt construction One-piece 20 Ga. housing. 20 Ga. steel socket bridges and galvanized end caps. Luminaires are available up to 8' nominal lengths. T5 and T5HO luminaires are shorter due to lamp length. 4' unit weight: 8' unit weight: 7 lbs 14 lbs optic Reflector fabricated of low iridescent, semi specular premium grade aluminum. electrical Luminaires are pre-wired with factory installed branch circuit wiring and over-molded quick connects. Electronic ballasts are thermally protected and have a Class “P” rating. Consult factory for dimming specifications and availability. UL and cUL listed. finish Polyester powder coat applied over a 5-stage pre-treatment. Standard luminaire housing finished in High Reflectance White. ballast Electronic Instant Start <20% THD E Electronic Program Start <10% THD Electronic Dimming Ballast* S D (T8 Only) CV mounting Cove CV factory options Emergency Circuit* EC Emergency Battery Pack* HLR/GLR Fuse EM FU Include 3000K Lamp L830 Include 3500K Lamp Include 4100K Lamp L835 L841 HW finish High Reflectance White HW luminaire length Designate length in feet (Nominal lengths: 2',3',4',5',6',7',8') XX' Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | T: 773.247.9494 | F: 773.247.8484 | info@focalpointlights.com | www.focalpointlights.com. Focal Point LLC reserves the right to change specifications for product improvement without notification. specifications 120 277 347 * for more information see Reference section. perimeter 363 co velight 26 TM 150° 140° LUMEN SUMMARY Zone Lumens % Lamp % Fixt 0 0 0 0 0 90°-120° 2828 28.3 36.9 5° 0 0 0 0 0 0 90°-130° 4175 41.7 54.5 120° 15° 0 0 0 0 0 0 90°-150° 6300 63.0 82.2 25° 0 0 0 0 0 0 90°-180° 7661 76.6 100.0 35° 0 0 0 0 0 0 0°-180° 7661 76.6 100.0 45° 0 0 0 0 0 0 55° 0 0 0 0 0 0 65° 0 0 0 0 0 0 90° 45° 75° 0 0 0 0 0 0 0° 85° 0 0 0 0 0 90° 0 0 0 0 0 95° 591 613 619 575 75 3845 3076 2307 1538 Test #: 12554.0 0° 90° 0 Efficiency: 82.5% 100° 769 110° Catalog #: FCV-26-1T5HO-1C-120-E-CV-HW-4’ VerticalHorizontal Angle Zonal Angle 0° 22.5° 45° 67.5° 90° Lumens 130° 0° 45° 90° Filename: FCVM261T5H.IES CANDLEPOWER DISTRIBUTION -150° -160° -170° 180 ° 170° 160° 0 Total Luminaire 378 105° 2259 2255 2130 1366 343 1077 115° 3679 3465 2775 1410 639 1373 125° 3843 3513 2600 1512 920 1347 135° 3453 3134 2344 1725 1216 1211 145° 2499 2359 2096 1700 1346 915 155° 2349 2265 2062 1790 2538 733 165° 2081 2033 1931 1744 1632 466 175° 1832 1813 1772 1733 1678 162 180° 1711 1711 1711 1711 1711 Go to www.focalpointlights.com for additional photometric data. covel i g h t st a n d a r d run length Continuous Runs consist of standard fixture lengths. Some fixtures may exceed nominal length consult individual cut sheets for details. Example: 31' run = three 8' fixtures and one 7' fixture. nominal run length (in feet) standard fixture lengths required lamp sizes nominal run length (in feet) standard fixture lengths required lamp sizes 2 2 2 32 8888 44444444 3 3 3 33 88863 444444333 4 4 4 34 88864 444444433 5 5 5 35 88883 444444443 6 6 33 36 88884 444444444 7 7 43 37 88867 4444444333 8 8 44 38 88886 4444444433 9 63 333 39 88887 4444444443 10 64 334 40 88888 4444444444 11 83 443 41 888863 44444444333 12 84 444 42 888864 44444444433 13 76 4333 43 888883 44444444443 14 86 4433 44 888884 44444444444 15 87 4443 45 888876 444444444333 16 88 4444 46 888886 444444444433 17 863 44333 47 888887 444444444443 18 864 44433 48 888888 444444444444 19 883 44443 49 8888863 4444444444333 20 884 44444 50 8888873 4444444444433 21 876 444333 22 886 444433 23 887 444443 24 888 444444 25 8863 4444333 26 8864 4444433 27 8883 4444443 28 8884 4444444 29 8876 44444333 30 8886 44444433 31 8887 44444443 www.focalpointlights.com | 1.773.247.9494 avenue a ® features Narrow aperture high performance T5/T5HO asymmetric wall wash. Precision micro-optic delivers shadow free illumination from the ceiling to the floor. Features 2" narrow aperture for clean unobtrusive aesthetic. Drywall installation is available, which allows for both individual or continuous row mount capability. Great solution for conference rooms, highlighting artwork, corridors, white board or any application that requires high levels of vertical illumination. detail dimensional data shielding options Grid Mount 4.00" 101.60mm Mounting yoke must be installed before drywall. (see Instruction Sheet #ISO214 for details) 3.50" 88.9mm frame width 4.75" max–4.625" min 3.20" 81.28mm 4.3" 109.22mm 6.5" 165.1mm clear lens companion luminaire 4.3" 109.22mm Drywall Flange open optic 24-30" Recommended Distance from Wall mr16 linear recessed wall mount performance 1–Lamp T5HO 57% Efficiency 1933 cd @ 25° lens Use in place of multiple halogen or compact fluorescent wall washers. www.focalpointlights.com | 1.773.247.9494 Visit focalpointlights.com for complete photometric data. april 2011 B .54" 13.72mm drywall row mount 2.20" 55.88mm 3.20" 81.28mm fixture: project: ordering mounting information Avenue A 1 1/ 2" 9/ 16" 15/ 16" Standard G1, T1, T1T 1 11/ 16" Standard G2, T2, T2T 9/ 16" No Shielding, Open Optic Snap-on Clear Lens tegular tile Slot tee G3 9/ 16" Tall G4, T4, T4T lay-in tile (Radial cut-off louver FAVA-RL cannot be field installed on the FAVA-NS or FAVA-CL) 1 1/ 2" 1 11/ 16" 15/ 16" Tall G5, T5, T5T FAVA shielding 1 1/ 2" 1 1/ 2" FAVA luminaire series grid NS CL lamping One Lamp T5 One Lamp T5HO 9/ 16" Node T6, T6T 1T5 1T5HO 1C circuits drywall Single Circuit 2' unit (cutout dimension: 3.5" x 23.6") 4' unit (cutout dimension: 3.5" x 47.6") voltage 3' unit (cutout dimension: 3.5" x 35.6") 5' unit (cutout dimension: 3.5" x 59.6") Drywall flange version provided with mounting yoke. 120 Volt 277 Volt 347 Volt 1C 120 277 347 ballast Electronic Program Start <10% THD Electronic Dimming Ballast* specifications ceiling configurations* One-piece 20 Ga. steel housing. Grid luminaires include 20 Ga. steel, .5" wide universal flange rail. Drywall flange option is provided with 20 Ga. steel, .5" wide flange kit and 20 Ga. galvanized steel mounting yoke. 2' 3' 4' 5' unit unit unit unit weight: weight: weight: weight: 5 6 7 8 lbs. lbs. lbs. lbs. optic .020" specular aluminum upper reflector and .020" semi-specular lower reflector. 24 Ga. perforated matte black diffuser with 24% opening. please note: radial cut-off louver FAVA-RL cannot be field installed on the non-shielded profile FAVA-NS. electrical Luminaires are individually wired for specified circuits. Thru-wiring not available. Electronic ballasts are thermally protected and have a Class “P” rating. Optional dimming ballasts available. Consult factory for dimming specifications and availability. UL and cUL listed. finish Polyester powder coat applied over a 5-stage pre-treatment. Perforated diffuser always finished in Matte Black. (Consult factory for custom variations) 1 1/ 2" 1 1/ 2" 1 1/ 2" 1 11/ 16" 1 11/ 16" 1 1/ 2" Std. 15/16" Lay-in Std. 15/16" Tegular Std. 15/16" Tegular, against Tee Std. 9/16" Lay-in Std. 9/16" Tegular Std. 9/16" Tegular, against Tee 9/16" Slot-tee Tegular Tall 15/16" Lay-in Tall 15/16" Tegular Tall 15/16" Tegular, against Tee Tall 9/16" Lay-in Tall 9/16" Tegular Tall 9/16" Tegular, against Tee Node 9/16" Tegular Node 9/16" Tegular, against Tee F G1 T1 T1T G2 T2 T2T G3 G4 T4 T4T G5 T5 T5T T6 T6T Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | T: 773.247.9494 | F: 773.247.8484 | info@focalpointlights.com | www.focalpointlights.com. Focal Point LLC reserves the right to change specifications for product improvement without notification. Drywall Flange construction S D factory options Chicago Plenum Emergency Battery Pack* CP EM (3' & 4' Luminaires Only) Earthquake Clips Flex Whip* HLR/GLR Fuse Include 3000K Lamp* Include 3500K Lamp* Include 4100K Lamp* Lutron™ Sensor Feed* (EcoSystem ballast required) EQ FW FU L830 L835 L841 SF finish Matte White Housing Titanium Silver Matte Black Housing (Perforated diffuser always painted black) WH TS BK luminaire length 2' 3' 4' 5' Nominal Nominal Nominal Nominal Housing Housing Housing Housing (Consult factory for 5' dimming) (For continuous row mount in drywall ceiling, specify luminaire run length, ie 24') 2' 3' 4' 5' * for more information see Reference section. recessed 363 avenue a ® 1950 1560 1170 780 390 0 0° 45° 90° Efficiency: 57% Test #: 12355.0 LUMEN SUMMARY Zone Lumens % Lamp % Fixt 0° 108 108 108 108 108 0°-30° 376 7.5 13.2 5° 276 256 214 154 101 13 0°-40° 784 15.7 27.4 70° 15° 919 771 499 291 102 85 0°-60° 1975 39.5 69.0 25° 1933 1873 1300 415 101 279 0°-90° 2861 57.2 100.0 35° 1832 1799 1695 707 96 408 0°-180° 2861 57.2 100.0 45° 1806 1775 1647 1296 88 610 55° 1434 1416 1329 1108 74 580 65° 1072 1052 962 811 56 473 75° 655 631 568 458 39 294 85° 317 294 224 129 14 119 90° 183 165 112 40 2 50° 30° 80° 60° 20° Catalog #: FAVA-NS-1T5HO-1C-120-S-G-WH-4’ VerticalHorizontal Angle Zonal Angle 0° 22.5° 45° 67.5° 90° Lumens 90° 10° Filename: FAVANS1T5H.IES CANDLEPOWER DISTRIBUTION 0° 40° 90° 45° 0° 95° 0 0 0 0 0 0 105° 0 0 0 0 0 0 115° 0 0 0 0 0 0 125° 0 0 0 0 0 0 135° 0 0 0 0 0 0 145° 0 0 0 0 0 0 155° 0 0 0 0 0 0 165° 0 0 0 0 0 0 175° 0 0 0 0 0 0 180° 0 0 0 0 0 Total Luminaire Go to www.focalpointlights.com for additional photometric data. a ven u e a g ri d c eiling configurations fixture position Avenue A is configured at our factory to integrate easily with your specified grid type, tile style and fixture position. Please review the below options and choose the mounting code that matches your application. 1 1/ 2" " 1 1/ 2G1 lay-in tile, any fixture placement 15/ 16" 1 " 1 3/ 4" 1 / 2 9/ 16" 1 1/ 2" 9/ 16" 1 " 1 3/ 4" 1 / 2G2 lay-in tile, any fixture placement 16" 9/ 16" 9/ 16" Standard 9/16" 1 1 3/ 4" 1 / 2" 1 11/ 16" 16" 2" 9/ 16" 1 " 1 3/ 4" 1 / 2 9/ 16" 9/ 16" G3 slot-tee tegular tile, any fixture placement 9/ 16" Slot Tee 9/16" 16" 9/ 16" 1 1 3/ 4" 1 / 2" 9/ 16" www.focalpointlights.com | 1.773.247.9494 tegular tile T1 T1T tegular tile, fixture between tees tegular tile, fixture against tee 1 1 3/ 4" 1 / 2" 1 11/ 16" 15/ 16" lay-in tile fixture against tee 9/ 16" Standard 15/16" 1 11/ 16" tile style fixture between tees 9/ 16" T2 T2T tegular tile, fixture between tees tegular tile, fixture against tee 1 1/ 2" 1 1/ 2" 15/ 16" 1 11/ 16" 1 " 1 3/ 4" 1 / 2 9/ 16" 1 11/ 16" G4 9/ 16" 1 1 3/ 4" 1 / 2" lay-in tile, any fixture placement 9/ 16" 15/ 16" T4 T4T tegular tile, fixture between tees tegular tile, fixture against tee 9/ 16" Tall 15/16" 2" 1 1/ 2" 15/ 16" 1/ 16" 1 " 1 3/ 4" 1 / 2 9/ 16" 1 1 3/ 4" 1 / 2" 1 11/ 16" 15/ 16" 9/ 16" 9/ 16" G5 T5 T5T lay-in tile, any fixture placement tegular tile, fixture between tees tegular tile, fixture against tee 9/ 16" Tall 9/16" 1 1/ 2" 1 " 1 3/ 4" 1 / 2 9/ 16" 1 11/ 16" 9/ 16" 9/ 16" 1 1 3/ 4" 1 / 2" T6 T6T tegular tile, fixture between tees tegular tile, fixture against tee 9/ 16" Node 9/16" reference 363 FEATURES OPTICAL SYSTEM • Reflector - Self-flanged, semi-specular or matte-diffuse reflector. Fluted vertical upper section works in conjunction with patented Bounding RayTM Optical Principle design (U.S. Patent No. 5,800,050) to provide lamp before lamp image and smooth transition from top of reflector to bottom. Minimum flange matches reflector finish. • Baffle/cone - Semi-specular clear upper reflector. Microgroove baffle with white painted flange or specular black cone with flange that matches cone finish. • Hinged lampdoor seals upper trim for optimal fixture efficiency and the reduction of stray light in the plenum. Type Catalog number ............................. ....................................................................................................... ............................. ....................................................................................................... Compact Fluorescent Downlights 8" AF Open Reflector Horizontal Lamp Triple-Tube MECHANICAL SYSTEM • 16-gauge galvanized steel mounting/plaster frame with integral yoke to retain optical system. Maximum 1-1/2" ceiling thickness. • 16-gauge galvanized steel mounting bars with continuous 4" vertical adjustment are shipped pre-installed. Post installation adjustment possible without the use of tools from above or below the ceiling. • Galvanized steel junction box with hinged access covers and spring latch. Two combination 1/2"–3/4" and three 1/ 2" knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated for 90°C. 8-3/4 (22.2) Aperture: 7-7/8 (20.1) Ceiling Opening: 8-7/8 (22.5) Overlap Trim: 9-1/4 (23.5) ELECTRICAL SYSTEM • Horizontally-mounted, positive-latch, thermoplastic socket. • Class P, thermally protected, high power factor electronic ballast mounted to the junction box. • Simply5TM technology available. LISTING • Fixtures are UL Listed for thru-branch wiring, Non-IC recessed mounting and damp locations. Listed and labeled to comply with Canadian Standards. 14-1/2 (36.8) All dimensions are inches (centimeters) 15-7/8 (40.3) ORDERING INFORMATION Example: AF 2/32TRT 8AR MVOLT Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog numbers (shipped separately). AF Series Wattage /Lamp AF 1/18TRT 1/26TRT 1/32TRT 1/42TRT 1/57TRT 2/18TRT 2/26TRT 2/32TRT 2/42TRT Aperture/Trim color 8AR 8PR 8UBR 8WTR 8WR1 8MB1 8WB 1 8BC 1 Clear Pewter Umber Wheat White painted Black baffle White baffle Black cone Finish (blank) Semispecular LD Mattediffuse NOTES 1 Not available with finishes. 2 Multi-volt electronic ballast capable of operating on any voltage from 120V through 277V, 50 or 60 Hz. 3 For additional ballast types, refer to Technical Bulletins. 4 Available in 120V or 277V only. Minimum dimming level 5%. 5 Simply5TM includes 9' S5 MLC Reloc wiring system (shipped separately). Available in 120V or 277V only. Not available in 18W or 57W. See simply5.net for more information. 6 For dimensional changes, refer to TECH-140. 7 For compatible Reloc systems, refer to TECH-110. 8 Not available with EL or ELR option. 9 Meets codes that require in-fixture disconnect. 10 One 5A relay with one 0-10 VDC dimming output, shipped installed. Requires additional nLight bus power supply. Voltage Ballast3 Options MVOLT 2 120 277 347 (blank) Electronic ballast ECOS EcoSystem electronic dimming ballast. Minimum dimming level 5%. ADEZ 4 Advance Mark 10® electronic dimming ballast. Minimum dimming level 5% S5 HW5 SIMPLY5TM ballast less Reloc EL 6 Emergency battery pack with integral test switch ELR 6 Emergency battery pack. Remote test switch GMF Single, slow-blow fuse (not available with MVOLT) GLR Single, fast-blow fuse (not available with MVOLT) TRW White painted flange (standard on MB and WB) TRBL Black painted flange WLP With 3500°K lamp (shipped separately) LRC7 Provides compatibility with Lithonia Reloc System. Reloc System can be installed less this option with connectors provided by others. Access above ceiling required 8 CP Chicago Plenum CSA CSA Certified BDP 9 Ballast disconnect plug ELHL 6 High lumen output emergency battery pack. Integral test switch provided 6 ELRHL High lumen output emergency battery pack. Remote test switch provided 10 NSD Sensorswitch nLightTM dimming relay Accessories Order as separate catalog number. SCA8 Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA8 10D AF 8 TRT OPEN DCF-180 8" AF Open Reflector Distribution curve Distribution data Output data Coefficient of utilization Illuminance Data at 30" Above Floor for a Single Luminaire AF 1/32TRT 8AR, (1) CF32DT/E/IN/835, 2400 lumens per lamp, 1.3 s/mh, Test no. LTL9452 From 0° 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° cp. 1005 1053 1140 1105 768 622 42 11 9 8 0 Lumens 95 275 416 405 354 46 11 10 8 Zone Lumens %lamp 0°-30° 785.7 0°-40° 1190.3 0°-60° 1590.4 0°-90° 1619.7 90°-180° 0.0 0°-180° 1619.7 32.7 49.6 66.3 67.5 0.0 67.5* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 74 67 62 56 52 48 44 41 38 35 72 64 57 52 47 43 39 36 33 31 72 66 61 56 51 47 43 40 37 35 70 63 57 51 47 43 39 36 33 30 69 64 59 54 50 46 43 39 37 34 68 61 56 50 46 42 38 35 33 30 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 33.2 17.9 11.1 7.6 5.5 50% 10% beam angle 61.0° beam angle 94.7° fc at fc at Beam beam Beam beam diameter edge diameter edge 6.5 8.8 11.2 13.5 15.9 16.6 8.9 5.6 3.8 2.8 11.9 16.3 20.6 25.0 29.3 3.3 1.8 1.1 0.8 0.6 AF 1/42TRT 8AR, (1) CF42DT/E/IN/835, 3200 lumens per lamp, 1.3 s/mh, Test no. LTL9455 From 0° cp. Lumens 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 1295 1303 1437 1347 998 848 42 4 1 0 0 122 373 588 570 464 49 4 1 0 Zone Lumens %lamp 0°-30° 1083.2 0°-40° 1653.4 0°-60° 2166.3 0°-90° 2171.7 90°-180° 0.0 0°-180° 2171.7 33.8 51.7 67.7 67.9 0.0 67.9* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 74 68 62 57 53 49 45 41 38 36 72 65 59 53 48 44 40 37 34 31 73 67 61 56 52 48 44 41 38 36 71 64 58 52 48 43 40 37 34 31 70 65 60 55 51 47 43 40 37 35 69 62 57 51 47 43 39 36 33 31 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 42.8 23.0 14.3 9.8 7.1 50% 10% beam angle 64.5° beam angle 94.8° fc at fc at Beam beam Beam beam diameter edge diameter edge 6.9 9.5 12.0 14.5 17.0 21.4 11.5 7.2 4.9 3.6 12.0 16.3 20.7 25.0 19.3 4.3 2.3 1.4 1.0 0.7 AF 2/32TRT 8AR, (2) CF32DT/E/IN/835, 2400 lumens per lamp, 1.4 s/mh, Test no. LTL9407 From 0° cp. 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 1584 1676 1720 1849 1348 830 36 5 2 0 0 Lumens 165 514 795 815 549 63 6 2 0 Zone Lumens %lamp 0°-30° 1473.7 0°-40° 2288.7 0°-60° 2901.1 0°-90° 2909.7 90°-180° 0.0 0°-180° 2909.7 30.7 47.7 60.4 60.6 0.0 60.6* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 66 61 56 51 47 44 40 37 35 32 65 58 52 48 43 39 36 33 31 28 65 60 55 51 47 43 40 37 34 32 64 57 52 47 43 39 36 33 30 28 63 58 53 49 46 42 39 36 34 31 61 56 51 46 42 39 35 33 30 28 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 52.4 28.2 17.6 12.0 8.7 50% 10% beam angle 67.9° beam angle 94.3° fc at fc at Beam beam Beam beam diameter edge diameter edge 7.4 10.1 12.8 15.5 18.2 26.2 14.1 8.8 6.0 4.3 11.9 16.2 20.5 24.8 29.1 5.2 2.8 1.8 1.2 0.9 AF 2/42TRT 8AR, (2) CF42DT/E/IN/835, 3200 lumens per lamp, 1.4 s/mh, Test no. LTL9406 From 0° 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° cp. Lumens 2211 2248 225 2270 707 2205 1097 1699 1137 1092 749 47 84 7 8 3 3 0 0 0 Zone Lumens %lamp 0°-30° 2029.5 0°-40° 3166.3 0°-60° 3999.6 0°-90° 4009.9 90°-180° 0.0 0°-180° 4009.9 *Efficiency 31.7 49.5 62.5 62.7 0.0 62.7* ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 69 63 58 53 49 45 42 39 36 33 67 60 54 49 45 41 37 34 32 29 67 62 57 52 48 45 41 38 36 33 66 59 54 49 44 40 37 34 31 29 65 60 55 51 47 44 40 37 35 33 64 58 52 48 44 40 37 34 31 29 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 73.1 39.3 24.5 16.7 12.1 50% 10% beam angle 67.6° beam angle 94.1° fc at fc at Beam beam Beam beam diameter edge diameter edge 7.4 10.0 12.7 15.4 18.1 36.5 19.7 12.2 8.4 6.1 11.8 16.1 20.4 24.7 29.0 7.3 3.9 2.4 1.7 1.2 ENERGY (Calculated in accordance with NEMA standard LE-5A) Annual* Energy Cost LER.DOL $5.44 44 $5.08 47 $5.93 40 $5.92 41 (1) (1) (2) (2) Lamps 32W TRT 42W TRT 32W TRT 42W TRT Lamp Lumens 2400 3200 4800 6400 Ballast Factor 0.98 1.00 0.96 0.95 Input Watts 36 46 69 94 * Comparative yearly lighting energy cost per 1000 lumens NOTES: 1 For electrical characteristics, refer to Technical Bulletins tab. 2 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications are based on the most current available data and are subject to change without notice. 3 Consult factory or IES file for microgroove baffle, black cone and other photometric reports. DCF-180 ©2003, 2009, 2011 Acuity Brands Lighting, Inc. Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — RT5 is designed for applications that require the extremely energy efficient delivery of comfortable volumetric light from a lay-in fixture that is appealing and shallow in depth. Ideal for offices, schools, hospitals, retail and numerous other commercial applications. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer light-diffusing film. Rugged, one-piece, cold-rolled steel reflector with embossed facets. Polyester powder paint after fabrication. Rigid structure with ballast box and endplates with integral T-bar clips. Fixtures may be mounted end-to-end. OPTICS — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal amount to walls, cubicles, work surfaces and people. Luminous characteristics are carefully managed at high angles, providing just enough intensity to deliver the volumetric effect. Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector with light. Linear faceted reflector softens and distributes light into the space and minimizes the luminance ratio between the fixture and the ceiling. Mechanical cut-off across the reflector and fresnel refraction along the refractor provide high angle shielding and a quiet ceiling. Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth. ELECTRICAL — Highly efficient program-start electronic ballasts, Class P, thermally protected, resetting, HPF, non-PCB, UL Listed, CSA Certified, sound rated A. Your choice of Premium or Premium XP T5 lamp with enhanced phosphors and 85 CRI. Ballast/lamp efficacy up to 100+ LPW. Lamp is TCLP compliant. 0.90 or 0.95 ballast factor standard for typical applications. 1.15 ballast factor or F54T5HO lamping available for higher ceiling height applications. Step-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance. S5 option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming. See SYNERGY® Lighting Controls specification sheets for more information. Ballast Disconnect provided standard where required to comply with U.S. and Canadian electrical codes. INSTALLATION — Side mounted ballast tray accessed by removing adjacent ceiling tile. Ballast tray may be removed from fixture during service. Lamps accessed by squeezing refractor to release from retention tabs. LISTING — UL Listed (standard). Optional: Canada CSA or cUL. Mexico NOM. WARRANTY — Fixture guaranteed for one year against mechanical defects in manufacture. Lamp and ballast system warranty (24 months for lamp, 60 months for ballast) by lamp and ballast manufacturer. ORDERING INFORMATION Type 2RT5 2'X 4' 2 Lamps Premier or Premier XP T5 Specifications Length: 48 (121.8) Width: 24 (61.0) Depth: 3-1/8 (7.9) 3-1/8 (7.9) 24 (61.0) All dimensions are inches (centimeters) unless otherwise specified. Protected by one or more of US Patents Nos. 7,229,192; D541,467; D541,468; D544,633; D544,634; D544,992; D544,933 and additional patent pending. Specifications subject to change without notice. Example: 2RT5 28T5 MVOLT GEB95 LPM835P For shortest lead times, configure products using bolded options. 2RT5 Series 2RT5 Recessed T5 Lamp type 28T5 28W T5 (46") 54T5HO 54W T5 (46")1 Voltage MVOLT 3473 2 Ballast Options Lamp7 GEB95 GEB95S GEB115 .95 ballast factor .95 ballast factor, step dimming4 1.15 ballast factor GEB115S 1.15 ballast factor, step dimming GEB10PS 1.0 ballast factor, program start5 S5 GEB80 .95 ballast factor SIMPLY5TM system6 .80 ballast factor1 GEB80S .80 ballast factor, step dimming1 GEB90 .90 ballast factor GEB90S .90 ballast factor, step dimming GEB10PS 1.0 ballast factor, program start4 LPM835P Premier 3500° K 28W lamp8 LPM830P Premier 3000° K 28W lamp8 LPM841P Premier 4100° K 28W lamp8 L835XP Premier XP 3500° K 28W lamp8 L830XP Premier XP 3000° K 28W lamp8 L841XP Premier XP 4100° K 28W lamp8 LP835 3500° K 54W lamp LP830 3000° K 54W lamp LP841 4100° K 54W lamp Notes 1 For T5HO applications, use GEB10PS, GEB80 or GEB80S ballast. 2 MVOLT (120-277 volts), 50-60HZ. 3 For 347V, use GEB95S or GEB10PS. 4 Only option for 347V. 5 Not available with 28T5. 6 SIMPLY5 includes 13' S5 SSC RELOC® wiring system, specify 7 8 9 10 11 12 GLR Internal fast-blow fuse9 PWS1836 6' prewire, 3/8" diameter, 18-gauge, 3-wire (n/a with step dimming)10 PWS1846 6' prewire, 3/8" diameter, 18-gauge, 4-wire11 EL14 Emergency battery pack12 EL65 Emergency battery pack12 HW Hardware for SIMPL5 system; replaces RELOC® CSA Listed and labeled to comply with Canadian standards BDP Ballast disconnect plug (meets codes that require in-fixture disconnect) voltage unless HW (hardwire) or PWS is ordered. Required. All fixtures shipped with lamps installed. 28T5 lamp type only. Must specify voltage, 120 or 277. For use with standard ballast. For use with step dimming ballast. See PS1400QD spec sheet for EL lumen output information. FLUORESCENT2 RT5-2X4 2RT5 Volumetric Recessed Lighting 2' x 4' 2RT5 28T5 GEB95 LPM835P, (2) FP28/835/PM/ECO lamps, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL13260 300 70˚ 600 50˚ 900 1200 1500 1800 10˚ 30˚ CP Summary 0˚ 90 0˚ 1770 1770 5˚ 1766 1750 15˚ 1695 1707 25˚ 1555 1623 35˚ 1339 1473 45˚ 1044 1280 55˚ 695 1071 65˚ 393 715 75˚ 179 257 85˚ 30 21 90 0 0 Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10% 0 107 107 107 105 105 105 100 100 100 1 98 94 91 92 89 86 88 86 83 2 89 82 76 81 75 70 77 73 69 3 82 72 65 71 64 59 68 63 58 4 75 64 56 63 56 50 61 54 49 5 69 57 49 56 49 43 54 48 43 6 63 52 44 51 43 38 49 42 37 7 59 47 39 46 39 33 45 38 33 8 55 43 35 42 35 30 41 34 30 9 51 39 32 39 32 27 38 31 27 10 48 36 29 36 29 24 35 28 24 RCR 90˚ Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0˚ - 30˚ 1383 25.3 28.2 0˚ - 40˚ 2264 41.5 46.1 0˚ - 60˚ 3976 72.8 81.0 0˚ - 90˚ 4908 89.9 100.0 90˚ - 180˚ 0 0.0 0.0 0˚ - 180˚ 4908 89.9 100.0 LER: 80.4 lpw Efficiency: 89.9% 0˚ 90˚ *The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration. Input Wattage Ballast120/277 GEB90 GEB90S GEB90S @50% power mode 55/54 27 GEB95 GEB95S 60/58 GEB95S @50% power mode 28/28 GEB115 GEB115S 73/71 GEB115S @50% power mode 35/35 GEB80 GEB80S 96/93 GEB80S @50% power mode 52/51 S5 60/58 T5/T8 Energy Comparison System 3-lamp T8 2RT5 2-lamp T5 2RT5 2-lamp T5 2RT5 2-lamp T5 Lamp Type Ballast Factor Input Watts Watts Saved Compared to T8 F32T8 F28T5XP F28T5 F28T5 0.88 0.90 0.95 1.15 88 54 58 71 – 34 30 17 2RT5-2X4 FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com ©2010 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/20/10 Catalog Number Notes Type FEATURES & SPECIFICATIONS ATTRIBUTES Slim, low-profile housing for ceiling or wall mounting. Matches AW Series in appearance. Choice of flat-bottom diffusers –– prismatic acrylic or matte white opal acrylic. Both available in high-impact versions. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. Diffuser hinges open from either side for easy cleaning and servicing. For surface or stem mounting, individual or row installation. Available in tandem-wired lengths. Guaranteed for one year against mechanical defects in manufacture. CONSTRUCTION Housing formed from cold-rolled 20-gauge steel. End plates welded to housing. Standard product complies with NYC requirements; no options necessary. No asbestos is used in this product. Thermally protected, resetting, Class P, HPF, non-PCB, UL listed, CSA certified ballast is standard. Ballasts are sound rated A. Standard combinations are CBM approved and conform to UL 935. FINISH High-gloss, baked white enamel finish. Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with high-gloss, baked white enamel. ELECTRICAL SYSTEM Fixture conforms to UL 1570 and is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. ENERGY Luminaire Efficacy Rating (LER) and Annual Energy Cost: Two-lamp LER.FW = 62. Annual Energy Cost = $3.87. Based on 32W T8 lamp, 2850 lumens, and energy-saving electronic ballast. Ballast factor = .88, input watts = 61. Corridor Acrylic Wraparound CA 2', 3', 4' and 8' Length 1 or 2 Lamps Calculated in accordance with NEMA standard LE-5. LISTING UL listed to US and Canadian safety standards (see Options). NOM Certified (see Options). Specifications subject to change without notice. Lead times may vary depending on options selected. Consult with your sales representative. Example: CA 2 32 MVOLT GEB10IS ORDERING INFORMATION Series CA Corridor wraparound For tandem doublelength unit, add prefix T. Example: TCA Number of lamps 1 2 Not included. Lamp type 17 25 28 32 17W T8 (24") 25W T8 (36") 28W T5 (46-1/2")1 32W T8 (48") Diffuser Voltage Options (blank) Prismatic AR High-impact prismatic ACW Matte white AWR High-impact matte white 347 MVOLT2 GEB10IS Electronic ballast, <10% THD, instant start GEB10PS Electronic ballast, <10% THD, program start EL Emergency battery pack (nominal 300 lumens; see Life Safety Section) GLR Internal fast-blow fuse3 GMF Internal slow-blow fuse3 RIF1 Radio interference filter (1 per fixture) CSA Listed and labeled to comply with Canadian Standards NOM NOM Certified Others available. Accessories Notes 1 2 3 All T5 lamp types use GEB10PS ballasts only. Electronic ballast operates 120V through 277V. Specify voltage. Fluorescent Order as separate item. SQ 1B DSH24 Swivel-stem hanger (specify in 2" increments) Ceiling spacer (adjusts from 1-1/2" to 2-1/2" from ceiling) Double-stem hanger for 4' fixtures, 24" stems Sheet #: CA WRAP-120 CA Corridor Acrylic Wraparound MOUNTING DATA DIMENSIONS For unit or row installation, surface or stem mounting. Stem mounting not available on TCB units. Inches (millimeters). Subject to change without notice. Individual installation — One double-stem (4' only) or two single-stem hangers required. Row installation — One hanger per fixture plus one per row required. See ACCESSORIES below for hanging devices. DSH C = 7/8 (22) Dia.K.O. D = 11/16 (17) Dia. K.O. E = 2 (51) Dia. K.O. and 7/8 (22) Dia. K.O. F = 7/16 (11) Dia.K.O. J = 11/16 x 1 (17 x 25) K.O. N = 5/16 (8) Dia. hole P = 5/16 x 3/4 (8 x 19) K.O. PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. CA 2 32 Report LTL 6020 – Lumens per lamp = 2900 S/MH (along) 1.2 (across) 1.5 Coefficient of Utilization Ceiling 80% 70% 50% Wall 70% 50% 30% 70% 50% 30% 50% 30% 10% 0% 0 1 2 3 4 5 6 7 8 9 10 87 78 71 65 59 54 50 46 42 39 36 83 75 68 62 56 52 47 44 40 37 35 77 66 57 51 45 40 36 32 29 26 24 64 51 42 36 30 26 22 19 17 14 12 87 774 64 57 50 44 39 35 32 29 26 87 70 59 50 43 37 33 29 25 22 20 83 71 62 54 48 43 38 34 31 28 25 83 68 57 49 42 36 32 28 25 22 19 77 63 53 46 40 34 30 27 23 21 18 0% 77 61 50 42 36 30 26 23 20 17 15 Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 886 1481 2627 3696 654 4350 15.3 25.5 45.3 63.7 11.3 75.0 20.4 34.0 60.4 85.0 15.0 100.0 Lithonia Lighting Sheet #: CA ©1996-2010 Acuity Brands Lighting, Inc., All rights reserved. Rev. 4/1/10 Fluorescent One Lithonia Way, Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com Catalog Number Notes FeatureS & specifications INTENDED USE — Suitable for cold weather (down to -40oC), wet location, security/prisons and highabuse applications. Type CONSTRUCTION — Durable cast aluminum construction – rugged, low-profile housing is .250 to .525" thick. NEMA 4X option available for wet and hose-down applications. Clear, UV-stable polycarbonate cover is .130" thick to prevent cracking or breaking. Cover is secured with four stainless steel, Torx T20 tamperproof screws with center pin. All-Conditions Exits Polycarbonate faceplate incorporates universal directional chevron knockouts that are concealed and easily removed and replaced. LV Universal mount (UM) option available – top, back, end mounting or conduit entry (canopy provided). Letters 6" high with 3/4" stroke, with 100 ft viewing distance rating. U.S. Patent No. 5,611,163 and D383,501. OPTICS — Lamp is constructed using new LED technology. Provides perfectly uniform illumination. White on white w/red letter color Expected LED life of up to 10 years, based on continuous operation. Single-face exit uses one LED lamp; double-face exit uses two LED lamps. Low energy consumption — red lamp consumes 2.3W (120V); green lamp consumes 1.7W (120V). LED LAMPS NEMA 4X Rating Available INSTALLATION — Universal and back (no canopy) mount available. Conduit entry (1/2" - 14 UNC) included with universal mounting. Cast-aluminum canopy attaches to 10-gauge steel mounting plate for top or end mounting (not required for back mounting). Canopy mounting bracket provides 160 lbs. of mounting strength when mounted to suitable structure. Bracket will only fit a 2-gang junction box. LISTINGS — UL listed. Listed and labeled to comply with Canadian Standards C-860 and C22.2 No. 9 (see Options). 4X option is UL listed to NEMA 4X ratings. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards, and State of Minnesota energy-efficient legislation requiring less than 20W consumption. Black on black w/green letter color WARRANTY — Five-year total customer satisfaction warranty on exit, including lamp. All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to p erform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. Ordering information LV Example: LV S W 1 R 120/277 For shortest lead times, configure products using bolded options. S Family Face type Faceplate/housing color Number of faces Letter color Input voltage Mounting LV (blank) Black faceplate on black housing W White on white WB White on black BW Black on white AB Aluminum on black1 AW Aluminum on white1 1 2 R G (blank) UM S Stencil Single face Double face2 Red Green1 120/277 Dual voltage1 120/347 Dual voltage3 Options Back mount Universal mount 4 (Blank) F1 X2 None Fire alarm flashing interface1 Primary and secondary AC inputs provided1,5,6 DL UL listed for damp locations 4X UL listed for NEMA 4X1 LDC6 6V DC input for LED lamps3 LDC12/48 12V-48V DC input for LED lamps3 CSA Listed and labeled to comply with Canadian Standards Notes Accessories: Order as separate catalog number. ELA TPS T20 emergencY Torx tamperproof bit for T20 center-pin screw 1 2 3 4 5 6 Not available with CSA option. Available with universal mount only. Only available with CSA option. Back mount standard with single face unless UM is specified. Not available on double face. UL listed as emergency lighting equipment. Must specify input voltage (120 or 277V). Not available dual voltage. LV_e LV LED, Extreme specifications Mounting All dimensions are in inches (centimeters). Shipping weight: 11 lbs. (5 kgs.) ELECTRICAL Primary Circuit Type Rated LED life1 Supply voltage Red 10 years 120 Red 10 years 277 Red 10 years 347 Green 10 years 120 Green 10 years 277 Number of lamps2 1 2 1 2 1 2 1 2 1 2 Input watts 2.3 4.6 2.2 4.4 1.12 3.16 1.7 2.8 1.9 3.3 End Mount Max. amps .15 .30 .13 .26 .29 .29 .087 .081 .089 .086 6 (15.2) 8.5 (21.6) 13-7/8 (35.2) 15 (38.1) Notes 1 Based on continuous operation. 2 Two-lamp version available with double-face only. Back Mount 13-7/8 (35.2) 8-3/4 (22.2) Supplemental Emergency Circuit Type No. of faces Nominal lamp voltage Electrical watts Input amps LDC6 1 6 1.44 .24 LDC12/48 1 12 1.9 .15 LDC12/48 1 24 1.8 .07 LDC12/48 1 32 1.8 .06 LDC12/48 1 48 1.7 .04 LDC6 2 6 2.9 .48 LDC12/48 2 12 3.1 .26 LDC12/48 2 24 3.1 .13 LDC12/48 2 32 3.3 .10 LDC12/48 2 48 3.4 .0 4 (10.2) 4-3/8 (11.1) 4-3/4 (12.1) 9-1/2 (24.1) Top Mount Top Mount Single-FaceDouble-Face 6 (15.2) 9-7/8 (24.9) Key FeatureS 3 (7.6) 4-1/4 (10.8) NEMA 4X Mounting Plate 4-3/8 (11.1) Unique LEDs provide extremely long life and low energy consumption. UL and CSA approved for damp or NEMA4X wet locations (see options). Cold weather — down to -40oC. 4-3/8 (11.1) Housing or canopy mounting bracket should be attached to mounting surface using suitable fastener for type of wall material. All four mounting hole positions should be used, and anchors or screws should have a minimum pullout rating of 160 lbs. Bracket will only fit a 2-gang junction box. Lv_e EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com © 1996-2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/16/11 Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — RT5™ is designed for applications that require the extremely energy efficient delivery of comfortable volumetric light from a lay-in fixture that is appealing and shallow in depth. Ideal for offices, schools, hospitals, retail and numerous other commercial applications. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. OPTICS — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal amount of light to walls, cubicles, work surfaces and people. Luminous characteristics are carefully managed at high angles to deliver just enough intensity to deliver the volumetric effect. Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector with light. Linear faceted reflector softens and distributes light into the space and minimizes the luminance ratio between the fixture and the ceiling. Mechanical cut-off across the reflector and fresnel refracton along the refractor provide high angle shielding and a quiet ceiling. Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth. CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer light diffusing film. Rugged, one-piece, cold-rolled steel reflector with embossed facets with polyester powder paint after fabrication. Rigid structure with ballast box and endplates with integral T-bar clips. Fixtures may be mounted end-to-end. ELECTRICAL — Highly efficient program start electronic ballasts, Class P, thermally protected, resetting, HPF, non PCB, UL Listed, CSA Certified, sound rated A. Your choice of Premium or Premium XP T5 lamp with enhanced phosphors and 85 CRI. Lamp is TCLP compliant. S5 option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming. See SYNERGY® Lighting Controls specification sheets for more information. Ballast Disconnect provided standard where required to comply with U.S. and Canadian electrical codes. INSTALLATION — Side mounted ballast tray accessed by removing adjacent ceiling tile. Ballast tray may be removed from fixture during service. Lamp accessed by squeezing refractor to release from retention tabs. LISTING — UL Listed (standard). Optional: Canada CSA or cUL. Mexico NOM. WARRANTY — Fixture guaranteed for one year against mechanical defects in manufacture. Lamp and ballast system warranty (24 months for lamp, 60 months for ballast) by lamp and ballast manufacturer. Protected by one or more of US Patents Nos. 7,229,192; D541,467; D541,468; D544,633; D544,634; D544,992; D544,933 and additional patent pending. Type RT5 1’x 4’ One or Two Lamps Premier and Premier XP T5 Specifications Length: 48 (121.8) Width: 12 (30.5) Depth: 3-1/8 (7.9) All dimensions are inches (centimeters) unless otherwise specified. Note: Specifications subject to change without notice. ORDERING INFORMATION RT5 Series RT5 Recessed T5 FLUORESCENT Example: RT5 1 28T5 MVOLT GEB10PS LPM835P For shortest lead times, configure products using bolded options. 28T5 Number of lamps 1 2 Lamp type 28T5 28W T5 (46") 54T5HO 54W T5HO (46")1 Voltage MVOLT 3473 Ballast 2 Lamp6 GEB10PS 1.0 ballast factor, program start4 GEB95 .95 ballast factor (2-lamp) GEB95S S5 .95 ballast factor, step dimming(2-lamp only) SIMPLY5TM system5 GEB80 .80 ballast factor1 GEB80S .80 ballast factor, step dimming1 GEB115 1.15 ballast factor (2-lamp only) GEB115S GEB90 1.15 ballast factor (2-lamp only), step dimming .90 ballast factor GEB90S .90 ballast factor, step dimming Options LPM835P Premier 3500°K lamp LPM830P Premier 3000°K lamp LPM841P Premier 4100°K lamp L835XP LP835 Premier 3500°K 28W lamp Premier 3000°K 28W lamp Premier 4100°K 28W lamp 3500°K, 54W lamp LP830 3000°K, 54W lamp LP841 4100°K, 54W lamp L830XP L841XP GLR Internal fast-blow fuse7 PWS1836 6' prewire, 3/8" diameter, 18-gauge, 3-wire (n/a with GEB95S)8 PWS1846 6' prewire, 3/8" diameter, 18-gauge, wire9 EL14 Emergency battery pack10 CSA Listed and labeled to comply with Canadian standards QFC_ Quick-flex cable7 BDP Ballast disconnect plug (meets codes that require in-fixture disconnect) Notes 1 For T5HO applications, use GEB10PS, GEB80 or GEB80S ballasts. 2 MVOLT (120-277 volts), 50-60HZ. 3 For 347V use GEB95S or GEB10PS ballast only. 4 GEB10PS for use with one-lamp 28T5, and one- and two-lamp 54T5HO. 5 SIMPLY5 includes 13’ S5 SSC RELOC® wiring system, specify voltage unless HW (hardwire) or PWS is ordered. Two-lamp = .95 ballast factor; one-lamp = 1.0 ballast factor. 6 Required. All fixtures shipped with lamps installed. 7 Must specify voltage, 120 or 277. 8 For use with standard ballast. 9 For use with step dimming ballast. 10 See PS1400QD spec sheet for EL lumen output information. RT5-1X4 RT5 Volumetric Recessed Lighting, 1' x 4' RT5 28T5 GEB10PS LPM835P, (1) FP28/835/PM/ECO lamp, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL13316 100 70˚ 200 300 400 50˚ 500 600 700 800 10˚ 0˚ 30˚ CP Summary 0˚ 90 0˚ 862 862 5˚ 848 862 15˚ 814 844 25˚ 747 792 35˚ 636 723 45˚ 492 636 55˚ 331 523 65˚ 189 323 75˚ 85 106 85˚ 15 13 0 90 0 Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10% 0 104 104 104 101 101 101 97 97 97 1 95 91 88 89 86 83 86 83 81 2 87 80 74 78 73 68 75 71 67 3 79 70 63 69 62 57 66 61 56 4 72 62 55 61 54 49 59 53 48 5 67 56 48 55 47 42 53 46 42 6 62 50 42 49 42 37 48 41 36 7 57 45 38 45 37 32 43 37 32 8 53 41 34 41 34 29 40 33 29 9 50 38 31 37 31 26 36 30 26 10 46 35 28 35 28 24 34 28 23 RCR 90˚ Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0˚ - 30˚ 672 24.6 28.3 0˚ - 40˚ 1100 40.3 46.3 0˚ - 60˚ 1940 71.1 81.7 0˚ - 90˚ 2375 87.0 100.0 90˚ - 180˚ 0 0.0 0.0 0˚ - 180˚ 2375 87.0 100.0 LER: 74.2 lpw Efficiency: 87.0% 90˚ RT5 2 28T5 GEB95S LPM835P, (2) FP28/835/PM/ECO lamp, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL14100 LER: 69.1 lpw *The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration. RT5-1X4 FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com ©2004-2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 1/10/11 Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Specification premium, high performance, static T8 luminaires provide general illumination for recessed applications; ideal for restricted plenum spaces. Specification Premium T8 Troffer SP8 2'x4' ATTRIBUTES Designed exclusively for use with T8 lamps, electronic ballasts and sockets. CONSTRUCTION Smooth hemmed sides and smooth, inward formed end flanges for safe handling. Lighter weight fixture allows safe, easy installation. Standard steel door frame has superior structural integrity with premium extruded appearance and precision flush mitered corners. Steel door allows easy lens replacement without frame disassembly (for lenses up to .156" thick). Powder-painted, steel latches provide easy, secure door closure. 2, 3, 4 or 6 Lamps T8 Superior mechanical light seal requires no foam gasketing. Integral T-bar clips secure fixture to T-bar system. Housing formed from cold-rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos is used in this product. US PATENTS: 6,210,025; 6,231,213; 6,213,625; 2,288,471. FINISH Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with highly reflective matte white enamel. OPTICAL A12 lens features reverse apex technology for superior lamp obscuration and improved visual comfort. ELECTRICAL SYSTEM Standard ballast is electronic, thermally protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA certified ballast, universal voltage and sound rated A. Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. LISTING Standard: UL. Optional: Canada — CSA or cUL; Mexico — NOM. WARRANTY Specifications Length: 48 (1218) Width: 24 (609) Depth: 3-11/16 (94) Weight: 22 lbs (9.9 kg) All dimensions are inches (millimeters). Guaranteed for one year against mechanical defects in manufacture. Specifications subject to change without notice. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: 2SP8 G 3 32 A12 MVOLT 1/3 GEB10IS 2SP8 Series 2SP8 2' wide Number of lamps 2 3 4 Voltage Options 1 (blank) Flush steel, white FN Flush aluminum, natural FM Flush aluminum, matte black 120 277 347 FW Flush aluminum, white MVOLT 1/4 One 4-lamp ballast 1/3 One 3-lamp ballast GEB10IS Electronic ballast, <10% THD, instant start GEB10RS Electronic ballast, <10% THD, rapid start EL Emergency battery pack (nominal 300 lumens EL14 Emergency battery pack (nominal 1400 lumens) Door frame 6 Not included. RN Regressed aluminum, natural RM Regressed aluminum, matte black RW Regressed aluminum, white Trim type Lamp type G Grid F Overlapping flanged 32 32W T8 (48") Diffuser type A12 #12 pattern acrylic, reverse apex A12125 #12 pattern acrylic, .125" thick RA125 #12 pattern acrylic, .125" thick, reverse apex A19 #19 pattern acrylic, .156" thick A15 PC1S PC2S NOTE: 1 MVOLT standard for 120-277V applications, 50-60 hz operation. Some options require voltage specified. Fluorescent Others available. PC3S #15 pattern acrylic, .2" thick 1/2" x 1/2" x 1/2" plastic cube louver, silver 1-1/2" x 1-1/2" x 1" plastic cube louver, silver w/ flange 3/4" x 3/4" x 1/2" plastic cube louver, silver GLR Internal fast-blow fuse GMF Internal slow-blow fuse LST Tandem-wired fixture pairs (shared ballasts) PWS1836 6' prewire, 3/8" dia., 18-gauge, 1 circuit PWS1846 6' prewire, 3/8" dia., 18-gauge, 2 circuits LP735 Lamped, 700-series, 3500K LP__ Lamped; specify lamp type and color JP Palletized and stretch-wrapped without individual cartons CSA CSA Certified NOM NOM Certified Sheet #: SP8-2x4 STAT-150 SP8 2'x4' Static T8 Troffer MOUNTING DATA DIMENSIONS Continuous row mounting of flanged units requires CRE and CRM trim options (see Options). NOTE: 1 Recommended rough-in dimensions for F-trim fixtures 24"x48". (Tolerance is +1/4"-0".) Swing-gate range 1-3/16" to 3-15/16". Swing-gate span 23-3/8" to 26-11/16". Fixture swing-gate points require additional 9/16" over nominal fixture height. PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. 2SP8 2 32 A12* Report LTL 7525 Lumens per lamp - 2850 – Lum. eff. - 85.5% S/MH (along) 1.3 (across) 1.4 Coefficient of Utilization 2SP8 3 32 A12* Report LTL 7492 Lumens per lamp - 2850 – Lum. eff. - 83.6% S/MH (along) 1.3 (across) 1.4 Coefficient of Utilization 2SP8 4 32 A12* Report LTL 7526 Lumens per lamp - 2850 – Lum. eff. - 81.5% S/MH (along) 1.2 (across) 1.4 Coefficient of Utilization Ceiling 80% Wall 70% 50% 30% 70% 70% 50% 30% 50% 50% 30% 10% Ceiling 80% Wall 70% 50% 30% 70% 70% 50% 30% 50% 50% 30% 10% Ceiling 80% Wall 70% 50% 30% 70% 70% 50% 30% 50% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 99 92 84 77 71 66 61 57 53 49 46 95 85 75 67 60 54 49 45 41 38 35 0 1 2 3 4 5 6 7 8 9 10 97 90 82 76 70 64 60 56 52 49 46 93 83 74 66 59 53 49 44 41 38 35 0 1 2 3 4 5 6 7 8 9 10 95 87 80 74 68 63 58 54 51 47 44 91 81 72 64 58 52 47 43 40 37 34 102 94 86 79 73 67 62 58 54 51 47 102 90 80 71 63 57 52 47 43 39 36 102 87 74 64 56 50 44 40 36 33 30 99 88 78 70 62 56 51 46 42 39 36 99 85 73 64 56 49 44 40 36 33 30 95 82 71 62 55 48 43 39 35 32 29 95 80 68 58 50 44 39 34 31 28 25 Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp 1541 2571 4192 4874 0 4874 27.0 45.1 73.5 85.5 0 85.5 100 92 84 78 72 66 61 57 53 50 47 100 88 78 70 62 56 51 46 42 39 36 100 85 73 63 55 49 44 39 36 32 30 Zone 31.6 52.7 86.0 100.0 0 100.0 LAMP 97 83 72 62 55 49 43 39 35 32 29 Zonal Lumens Summary %Fixture 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp 2319 3833 6164 7147 0 7147 27.1 44.8 72.1 83.6 0 83.6 Energy (Calculated in accordance with NEMA standard LE-5) ANNUAL 97 86 77 68 61 55 50 46 42 38 36 LAMP %Fixture 32.4 53.6 86.2 100.0 0 100.0 93 80 70 61 54 48 43 38 35 32 29 93 78 66 57 49 43 38 34 31 28 25 97 90 82 76 70 64 60 56 52 48 46 97 86 76 68 61 55 50 45 41 38 35 97 83 71 62 54 48 43 38 35 32 29 95 84 75 67 60 54 49 44 41 38 35 95 81 70 61 53 47 42 38 34 31 29 91 78 68 59 52 46 42 37 34 31 28 91 76 65 55 48 42 37 33 30 27 25 Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp 3029 4999 8017 9292 0 9292 26.6 43.8 70.3 81.5 0 81.5 %Fixture 32.6 53.8 86.3 100.0 0 100.0 * With reverse apex lens BALLAST LER.FL ENERGY COST ** DESCRIPTION LUMENS FACTOR 77 $3.12 (2) 32W T8 2850 .90 74 $3.24 (3) 32W T8 2850 .87 77 $3.12 (4) 32W T8 2850 .88 ** Comparative yearly lighting energy cost per 1000 lumens WATTS 57 85 107 Lithonia Lighting Sheet #: SP8-2x4 © 1999 Acuity Brands Lighting, Inc., Rev. 3/12/09 Fluorescent One Lithonia Way, Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com Type: ________________________ Bruno Indirect T8 S P E C I F I C AT I O N S Project: ______________________ Pendant Mount — Modular / 8” X 2” Rectangular BRM1 CATALOG NUMBER __________ __________ __________ __________ __________ FT __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________ Examples: BRM1 2 32 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 SCEP — BRM1 3 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 AVAILABLE FIXTURES ■ BRM1 - 1 ■ BRM1 - 2 ■ BRM1 - 3 1 11⁄16” 1 11⁄16” 8 1⁄4” 1 11⁄16” 8 1⁄4” 8 1⁄4” SPECIFICATIONS Construction Finish Fixture Length Housing is a nominal 8 1⁄4” x 1 11⁄16” rectangular channel formed from cold-rolled steel. 5⁄8” thick aluminum die cast end cap is standard, 4” sculpted die cast aluminum end cap is optional. Fine textured white polyester powder paint is standard. Consult factory for special finish requirements. 4’ 3⁄8”, 8’ and 12’ lengths in a single section for nominal support spacing 4’-0” and 8’-0”. For total fixture length, add 5⁄8” for each flat end cap and 4” for each sculpted end cap. Using internal joiners, 4’ and 8’ sections can be joined to form longer rows. Consult factory for availability of 12’ length fixture section. Electrical Specify 120V, 277V, or 347V. Pre-wired with 16AWG fixture wire. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed and labeled. Reflectors Die formed specular reflector with 95% reflectance. ORDERING LOGIC Use guide below to order complete fixture runs from four feet to one-hundred feet in increments of four. ______________ ______________ ________________ ______________ ___________ FT ______________ ______________ ________________________ ______________ Fixture # of Lamps in Cross Section Lamp Type Reflector Ballast Type SPR Maximum Section Length Voltage 32 Nominal Row Length1 120 277 347 GEB10 ADEZ4 ECO104 ADZT4 # of Emergency Modules2 BRM1 1 2 3 ______________ Emergency Type2,3 Specular Reflector R4 R8 R12 ______________ ________________ ______________ / ______________ Switching Lamp Color Mounting Type Blank No Emergency or SCT Night Light EL Emergency DCT Battery Pack EC Emergency / Night Light Circuit EN Emergency Battery Pack with Night Light Circuit Single L/LP Circuit LP730 Dual Circuit LP735 LP741 LP830 LP835 LP841 No Lamp 3000K 70+ CRI 3500K 70+ CRI 4100K 70+ CRI 3000K 80+ CRI 3500K 80+ CRI 4100K 80+ CRI Reference Lamp Chart on website or consult factory for other options. F1 F1A F2 F3 F4A F4B F4C / T-Bar Ceiling (Universal Mounting Bracket) T-Bar Ceiling (UMB with Integrated J-Box) Hard Ceiling (Horizontal J-Box) Stem Mount IDS Clip 15⁄16” Tee IDS Clip 9⁄16” Tee IDS Clip Screw Slot <10% THD ELECTRONIC Advance Mark 10 dimming Lutron ECO-10 dimming Advance Mark 7 0-10v dimming Blank 1SE 2SE Reference Ballast Chart on website or consult XSE factory for other options. No Emergency 1 section 2 sections X sections ______________ _________________________________ Overall Suspension Finish Options 12 15 18 21 24 XX C210 ACG APF CP DL DU ELH ELS GLR GMF NYC SCEP 12” overall suspension 15” overall suspension 18” overall suspension 21” overall suspension 24” overall suspension XX” overall suspension Standard White White (finetextured low gloss) C110 Painted to match Aluminum Finish C099 Custom Color Adjustable Cable Grippers Alternate Power Feed Chicago Plenum Damp Location Label Dust Cover EM Through wire w/ Separate Feed EM Through Wire w/ Single Feed Fusing (Fast blow) Fusing (Slow Blow) New York City Code Sculptured End Cap Notes: 1 2 3 4 Must be in 4’ increments. Optional. EL and EC are installed in last 4’ of fixture sections and are not available concurrently with each other. Separate feed required for each EL or EC unless ELS/ELH is specified. Not available in 347 volt. PEERLESS LIGHTING • Box 2556, Berkeley, CA 94702-0556 • Tel: 510.845.2760 • Fax: 510.845.2776 • www.peerless-lighting.com © 2008 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark, and “Peerless Bruno” is a trademark of Acuity Brands Lighting. Products in this brochure may be covered by one or more U.S. Patents and Patents Pending. Peerless Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program. Bruno Type: ________________________ Project: ______________________ Indirect T8 PHOTOMETRICS 1-LAMP T8 with SPECULAR reflector Pendant Mount — Modular / 8” X 2” Rectangular BRM1 2-LAMP T8 with SPECULAR reflector 3-LAMP T8 with SPECULAR reflector PEERLESS LIGHTING • Box 2556, Berkeley, CA 94702-0556 • Tel: 510.845.2760 • Fax: 510.845.2776 • www.peerless-lighting.com © 2008 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark, and “Peerless Bruno” is a trademark of Acuity Brands Lighting. Products in this brochure may be covered by one or more U.S. Patents and Patents Pending. Peerless Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.