covel i g h t 2 6
™
features
Low profile indirect luminaire designed for
concealed cove applications.
Luminaires are provided with quick connect
thru–wire harness for easy installation in
continuous runs.
Luminaire housing length designed around
specified lamp length to minimize socket
shadow.
Continuous run lengths may be configured
with combinations of luminaire lengths up
to 8'.
Covelight™ provides pleasing and even
illumination that highlights architectural
details.
dimensional data
details
2.00"
50.8mm
6.00"
152.4mm
thru–wire
harness
july 2008 A
lamping options
T8 LAMPS
T5/T5HO LAMPS
performance
1–Lamp T5HO
76.6% Efficiency
3843 cd @ 125°
Visit focalpointlights.com for
complete photometric data.
www.focalpointlights.com | 1.773.247.9494
fixture:
project:
ordering
details
luminaire series
fixture lengths
t8
Covelight T5/T5HO
Covelight T8
t5/t5ho
24.00"
22.40"
2'
36.00"
2" x 6"
34.30"
46.10"
4'
One Lamp T8
(FCVA only)
4'
60.00"
57.90"
5'
5'
72.00"
68.50"
6'
6'
84.00"
7'
80.30"
7'
96.00"
8'
26
lamping
3'
48.00"
26
profile
2'
3'
FCVM
FCVA
92.10"
8'
One Lamp T5
One Lamp T5HO
Two Lamp T5
Two Lamp T5HO
(T5 units supplied to match lamp length
See Luminaire Lengths chart for more
information)
1T8
1T5
1T5HO
2T5
2T5HO
circuit
Single Circuit
Dual Circuit
(Two lamps only)
1C
2C
voltage
120 Volt
277 Volt
347 Volt
construction
One-piece 20 Ga. housing.
20 Ga. steel socket bridges and galvanized end caps.
Luminaires are available up to 8' nominal lengths.
T5 and T5HO luminaires are shorter due to lamp length.
4' unit weight:
8' unit weight:
7 lbs
14 lbs
optic
Reflector fabricated of low iridescent, semi specular premium grade aluminum.
electrical
Luminaires are pre-wired with factory installed branch circuit wiring and
over-molded quick connects.
Electronic ballasts are thermally protected and have a Class “P” rating.
Consult factory for dimming specifications and availability.
UL and cUL listed.
finish
Polyester powder coat applied over a 5-stage pre-treatment.
Standard luminaire housing finished in High Reflectance White.
ballast
Electronic Instant Start <20% THD
E
Electronic Program Start <10% THD
Electronic Dimming Ballast*
S
D
(T8 Only)
CV
mounting
Cove
CV
factory options
Emergency Circuit*
EC
Emergency Battery Pack*
HLR/GLR Fuse
EM
FU
Include 3000K Lamp
L830
Include 3500K Lamp
Include 4100K Lamp
L835
L841
HW
finish
High Reflectance White
HW
luminaire length
Designate length in feet
(Nominal lengths: 2',3',4',5',6',7',8')
XX'
Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | T: 773.247.9494 | F: 773.247.8484 | info@focalpointlights.com | www.focalpointlights.com.
Focal Point LLC reserves the right to change specifications for product improvement without notification.
specifications
120
277
347
* for more information see Reference section.
perimeter
363
co velight 26
TM
150°
140°
LUMEN SUMMARY
Zone Lumens
%
Lamp
%
Fixt
0
0
0
0
0
90°-120°
2828
28.3
36.9
5°
0
0
0
0
0
0
90°-130°
4175
41.7
54.5
120° 15°
0
0
0
0
0
0
90°-150°
6300
63.0
82.2
25°
0
0
0
0
0
0
90°-180°
7661
76.6
100.0
35°
0
0
0
0
0
0
0°-180°
7661
76.6
100.0
45°
0
0
0
0
0
0
55°
0
0
0
0
0
0
65°
0
0
0
0
0
0
90°
45°
75°
0
0
0
0
0
0
0°
85° 0
0
0
0
0
90°
0
0
0
0
0
95°
591
613
619
575
75
3845
3076
2307
1538
Test #: 12554.0
0°
90°
0
Efficiency: 82.5%
100°
769
110°
Catalog #: FCV-26-1T5HO-1C-120-E-CV-HW-4’
VerticalHorizontal Angle
Zonal
Angle 0°
22.5°
45°
67.5° 90° Lumens
130°
0°
45°
90°
Filename: FCVM261T5H.IES
CANDLEPOWER DISTRIBUTION
-150° -160° -170° 180 ° 170° 160°
0
Total
Luminaire
378
105°
2259 2255 2130 1366 343 1077
115°
3679 3465 2775 1410 639 1373
125°
3843 3513 2600 1512 920 1347
135°
3453 3134 2344 1725 1216 1211
145°
2499 2359 2096 1700 1346 915
155°
2349 2265 2062 1790 2538 733
165°
2081 2033 1931 1744 1632 466
175°
1832 1813 1772 1733 1678 162
180°
1711 1711 1711 1711 1711
Go to www.focalpointlights.com for additional photometric data.
covel i g h t st a n d a r d run length
Continuous Runs consist of standard fixture lengths. Some fixtures may exceed nominal length consult individual
cut sheets for details.
Example: 31' run = three 8' fixtures and one 7' fixture.
nominal run
length (in feet)
standard fixture
lengths required
lamp sizes
nominal run
length (in feet)
standard fixture
lengths required
lamp sizes
2
2
2
32
8888
44444444
3
3
3
33
88863
444444333
4
4
4
34
88864
444444433
5
5
5
35
88883
444444443
6
6
33
36
88884
444444444
7
7
43
37
88867
4444444333
8
8
44
38
88886
4444444433
9
63
333
39
88887
4444444443
10
64
334
40
88888
4444444444
11
83
443
41
888863
44444444333
12
84
444
42
888864
44444444433
13
76
4333
43
888883
44444444443
14
86
4433
44
888884
44444444444
15
87
4443
45
888876
444444444333
16
88
4444
46
888886
444444444433
17
863
44333
47
888887
444444444443
18
864
44433
48
888888
444444444444
19
883
44443
49
8888863
4444444444333
20
884
44444
50
8888873
4444444444433
21
876
444333
22
886
444433
23
887
444443
24
888
444444
25
8863
4444333
26
8864
4444433
27
8883
4444443
28
8884
4444444
29
8876
44444333
30
8886
44444433
31
8887
44444443
www.focalpointlights.com | 1.773.247.9494
avenue a
®
features
Narrow aperture high performance T5/T5HO
asymmetric wall wash.
Precision micro-optic delivers shadow free
illumination from the ceiling to the floor.
Features 2" narrow aperture for clean
unobtrusive aesthetic.
Drywall installation is available, which
allows for both individual or continuous row
mount capability.
Great solution for conference rooms,
highlighting artwork, corridors, white board
or any application that requires high levels
of vertical illumination.
detail
dimensional data
shielding options
Grid Mount
4.00"
101.60mm
Mounting yoke must be
installed before drywall.
(see Instruction Sheet
#ISO214 for details)
3.50"
88.9mm
frame width
4.75" max–4.625" min
3.20"
81.28mm
4.3"
109.22mm
6.5"
165.1mm
clear lens
companion luminaire
4.3"
109.22mm
Drywall Flange
open optic
24-30" Recommended
Distance from Wall
mr16
linear
recessed
wall mount
performance
1–Lamp T5HO
57% Efficiency
1933 cd @ 25°
lens
Use in place of multiple halogen or
compact fluorescent wall washers.
www.focalpointlights.com | 1.773.247.9494
Visit focalpointlights.com for
complete photometric data.
april 2011 B
.54"
13.72mm
drywall row
mount
2.20"
55.88mm
3.20"
81.28mm
fixture:
project:
ordering
mounting information
Avenue A
1 1/ 2"
9/ 16"
15/ 16"
Standard
G1, T1, T1T
1 11/ 16"
Standard
G2, T2, T2T
9/ 16"
No Shielding, Open Optic
Snap-on Clear Lens
tegular tile
Slot tee
G3
9/ 16"
Tall
G4, T4, T4T
lay-in tile
(Radial cut-off louver FAVA-RL
cannot be field installed on the
FAVA-NS or FAVA-CL)
1 1/ 2"
1 11/ 16"
15/ 16"
Tall
G5, T5, T5T
FAVA
shielding
1 1/ 2"
1 1/ 2"
FAVA
luminaire series
grid
NS
CL
lamping
One Lamp T5
One Lamp T5HO
9/ 16"
Node
T6, T6T
1T5
1T5HO
1C
circuits
drywall
Single Circuit
2' unit (cutout dimension: 3.5" x 23.6")
4' unit (cutout dimension: 3.5" x 47.6")
voltage
3' unit (cutout dimension: 3.5" x 35.6")
5' unit (cutout dimension: 3.5" x 59.6")
Drywall flange version provided with mounting yoke.
120 Volt
277 Volt
347 Volt
1C
120
277
347
ballast
Electronic Program Start <10% THD
Electronic Dimming Ballast*
specifications
ceiling configurations*
One-piece 20 Ga. steel housing.
Grid luminaires include 20 Ga. steel, .5" wide universal flange rail.
Drywall flange option is provided with 20 Ga. steel, .5" wide flange kit and 20 Ga.
galvanized steel mounting yoke.
2'
3'
4'
5'
unit
unit
unit
unit
weight:
weight:
weight:
weight:
5
6
7
8
lbs.
lbs.
lbs.
lbs.
optic
.020" specular aluminum upper reflector and .020" semi-specular lower reflector.
24 Ga. perforated matte black diffuser with 24% opening.
please note:
radial cut-off louver FAVA-RL cannot be field installed on the non-shielded profile
FAVA-NS.
electrical
Luminaires are individually wired for specified circuits.
Thru-wiring not available.
Electronic ballasts are thermally protected and have a Class “P” rating.
Optional dimming ballasts available.
Consult factory for dimming specifications and availability.
UL and cUL listed.
finish
Polyester powder coat applied over a 5-stage pre-treatment.
Perforated diffuser always finished in Matte Black.
(Consult factory for custom variations)
1 1/ 2"
1 1/ 2"
1 1/ 2"
1 11/ 16"
1 11/ 16"
1 1/ 2"
Std. 15/16" Lay-in
Std. 15/16" Tegular
Std. 15/16" Tegular, against Tee
Std. 9/16" Lay-in
Std. 9/16" Tegular
Std. 9/16" Tegular, against Tee
9/16" Slot-tee Tegular
Tall 15/16" Lay-in
Tall 15/16" Tegular
Tall 15/16" Tegular, against Tee
Tall 9/16" Lay-in
Tall 9/16" Tegular
Tall 9/16" Tegular, against Tee
Node 9/16" Tegular
Node 9/16" Tegular, against Tee
F
G1
T1
T1T
G2
T2
T2T
G3
G4
T4
T4T
G5
T5
T5T
T6
T6T
Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | T: 773.247.9494 | F: 773.247.8484 | info@focalpointlights.com | www.focalpointlights.com.
Focal Point LLC reserves the right to change specifications for product improvement without notification.
Drywall Flange
construction
S
D
factory options
Chicago Plenum
Emergency Battery Pack*
CP
EM
(3' & 4' Luminaires Only)
Earthquake Clips
Flex Whip*
HLR/GLR Fuse
Include 3000K Lamp*
Include 3500K Lamp*
Include 4100K Lamp*
Lutron™ Sensor Feed*
(EcoSystem ballast required)
EQ
FW
FU
L830
L835
L841
SF
finish
Matte White Housing
Titanium Silver
Matte Black Housing
(Perforated diffuser always painted black)
WH
TS
BK
luminaire length
2'
3'
4'
5'
Nominal
Nominal
Nominal
Nominal
Housing
Housing
Housing
Housing
(Consult factory for 5' dimming)
(For continuous row mount in drywall
ceiling, specify luminaire run length, ie 24')
2'
3'
4'
5'
* for more information see Reference section.
recessed
363
avenue a
®
1950
1560
1170
780
390
0
0°
45°
90°
Efficiency: 57%
Test #: 12355.0
LUMEN SUMMARY
Zone Lumens
%
Lamp
%
Fixt
0°
108
108
108
108
108
0°-30°
376
7.5
13.2
5°
276
256
214
154
101
13
0°-40°
784
15.7
27.4
70°
15°
919
771
499
291
102
85
0°-60°
1975
39.5
69.0
25°
1933 1873 1300
415
101
279
0°-90°
2861
57.2
100.0
35°
1832 1799 1695
707
96
408
0°-180°
2861
57.2
100.0
45°
1806 1775 1647 1296
88
610
55°
1434 1416 1329 1108
74
580
65°
1072 1052
962
811
56
473
75°
655
631
568
458
39
294
85° 317
294
224
129
14
119
90°
183
165
112
40
2
50°
30°
80°
60°
20°
Catalog #: FAVA-NS-1T5HO-1C-120-S-G-WH-4’
VerticalHorizontal Angle
Zonal
Angle 0°
22.5°
45°
67.5° 90° Lumens
90°
10°
Filename: FAVANS1T5H.IES
CANDLEPOWER DISTRIBUTION
0°
40°
90°
45°
0°
95°
0
0
0
0
0
0
105°
0
0
0
0
0
0
115°
0
0
0
0
0
0
125°
0
0
0
0
0
0
135°
0
0
0
0
0
0
145°
0
0
0
0
0
0
155°
0
0
0
0
0
0
165°
0
0
0
0
0
0
175°
0
0
0
0
0
0
180°
0
0
0
0
0
Total
Luminaire
Go to www.focalpointlights.com for additional photometric data.
a ven u e a g ri d c eiling configurations
fixture position
Avenue A is configured at our factory to integrate easily
with your specified grid type, tile style and fixture position.
Please review the below options and choose the mounting
code that matches your application.
1 1/ 2"
"
1 1/ 2G1
lay-in tile,
any fixture placement
15/ 16"
1 "
1 3/ 4" 1 / 2
9/ 16"
1 1/ 2"
9/ 16"
1 "
1 3/ 4" 1 / 2G2
lay-in tile,
any fixture placement
16"
9/ 16"
9/ 16"
Standard 9/16"
1
1 3/ 4" 1 / 2"
1 11/ 16"
16"
2"
9/ 16"
1 "
1 3/ 4" 1 / 2
9/ 16"
9/ 16"
G3
slot-tee tegular tile,
any fixture placement
9/ 16"
Slot Tee 9/16"
16"
9/ 16"
1
1 3/ 4" 1 / 2"
9/ 16"
www.focalpointlights.com | 1.773.247.9494
tegular tile
T1
T1T
tegular tile,
fixture between tees
tegular tile,
fixture against tee
1
1 3/ 4" 1 / 2"
1 11/ 16"
15/ 16"
lay-in tile
fixture against tee
9/ 16"
Standard 15/16"
1 11/ 16"
tile style
fixture between tees
9/ 16"
T2
T2T
tegular tile,
fixture between tees
tegular tile,
fixture against tee
1 1/ 2"
1 1/ 2"
15/ 16"
1 11/ 16"
1 "
1 3/ 4" 1 / 2
9/ 16"
1 11/ 16" G4
9/ 16"
1
1 3/ 4" 1 / 2"
lay-in tile,
any fixture placement
9/ 16"
15/ 16"
T4
T4T
tegular tile,
fixture between tees
tegular tile,
fixture against tee
9/ 16"
Tall 15/16"
2"
1 1/ 2"
15/ 16"
1/ 16"
1 "
1 3/ 4" 1 / 2
9/ 16"
1
1 3/ 4" 1 / 2"
1 11/ 16"
15/ 16"
9/ 16"
9/ 16"
G5
T5
T5T
lay-in tile,
any fixture placement
tegular tile,
fixture between tees
tegular tile,
fixture against tee
9/ 16"
Tall 9/16"
1 1/ 2"
1 "
1 3/ 4" 1 / 2
9/ 16"
1 11/ 16"
9/ 16"
9/ 16"
1
1 3/ 4" 1 / 2"
T6
T6T
tegular tile,
fixture between tees
tegular tile,
fixture against tee
9/ 16"
Node 9/16"
reference
363
FEATURES
OPTICAL SYSTEM
• Reflector - Self-flanged, semi-specular or matte-diffuse
reflector. Fluted vertical upper section works in conjunction with patented Bounding RayTM Optical Principle
design (U.S. Patent No. 5,800,050) to provide lamp before
lamp image and smooth transition from top of reflector
to bottom. Minimum flange matches reflector finish.
• Baffle/cone - Semi-specular clear upper reflector.
Microgroove baffle with white painted flange or specular
black cone with flange that matches cone finish.
• Hinged lampdoor seals upper trim for optimal fixture
efficiency and the reduction of stray light in the plenum.
Type
Catalog number
.............................
.......................................................................................................
.............................
.......................................................................................................
Compact Fluorescent Downlights
8" AF
Open Reflector
Horizontal Lamp
Triple-Tube
MECHANICAL SYSTEM
• 16-gauge galvanized steel mounting/plaster frame with
integral yoke to retain optical system. Maximum 1-1/2"
ceiling thickness.
• 16-gauge galvanized steel mounting bars with continuous 4" vertical adjustment are shipped pre-installed.
Post installation adjustment possible without the use of
tools from above or below the ceiling.
• Galvanized steel junction box with hinged access covers
and spring latch. Two combination 1/2"–3/4" and three 1/
2" knockouts for straight-through conduit runs. Capacity:
8 (4 in, 4 out) No. 12 AWG conductors, rated for 90°C.
8-3/4
(22.2)
Aperture:
7-7/8 (20.1)
Ceiling Opening: 8-7/8 (22.5)
Overlap Trim:
9-1/4 (23.5)
ELECTRICAL SYSTEM
• Horizontally-mounted, positive-latch, thermoplastic
socket.
• Class P, thermally protected, high power factor electronic ballast mounted to the junction box.
• Simply5TM technology available.
LISTING
• Fixtures are UL Listed for thru-branch wiring, Non-IC
recessed mounting and damp locations. Listed and
labeled to comply with Canadian Standards.
14-1/2
(36.8)
All dimensions
are inches
(centimeters)
15-7/8
(40.3)
ORDERING INFORMATION
Example: AF 2/32TRT 8AR MVOLT
Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate
line. Order accessories as separate catalog numbers (shipped separately).
AF
Series Wattage
/Lamp
AF
1/18TRT
1/26TRT
1/32TRT
1/42TRT
1/57TRT
2/18TRT
2/26TRT
2/32TRT
2/42TRT
Aperture/Trim color
8AR
8PR
8UBR
8WTR
8WR1
8MB1
8WB 1
8BC 1
Clear
Pewter
Umber
Wheat
White painted
Black baffle
White baffle
Black cone
Finish
(blank) Semispecular
LD Mattediffuse
NOTES
1 Not available with finishes.
2 Multi-volt electronic ballast capable of operating on any voltage
from 120V through 277V, 50 or 60 Hz.
3 For additional ballast types, refer to Technical Bulletins.
4 Available in 120V or 277V only. Minimum dimming level 5%.
5 Simply5TM includes 9' S5 MLC Reloc wiring system (shipped separately). Available in 120V or 277V only. Not available in 18W or 57W.
See simply5.net for more information.
6 For dimensional changes, refer to TECH-140.
7 For compatible Reloc systems, refer to TECH-110.
8 Not available with EL or ELR option.
9 Meets codes that require in-fixture disconnect.
10 One 5A relay with one 0-10 VDC dimming output, shipped
installed. Requires additional nLight bus power supply.
Voltage
Ballast3
Options
MVOLT 2
120
277
347
(blank) Electronic ballast
ECOS EcoSystem
electronic
dimming ballast.
Minimum
dimming level 5%.
ADEZ 4 Advance Mark 10®
electronic dimming ballast.
Minimum dimming
level 5%
S5 HW5 SIMPLY5TM
ballast less Reloc
EL 6 Emergency battery pack
with integral test switch
ELR 6 Emergency battery pack.
Remote test switch
GMF Single, slow-blow fuse (not
available with MVOLT)
GLR Single, fast-blow fuse (not
available with MVOLT)
TRW White painted flange
(standard on MB and WB)
TRBL Black painted flange
WLP With 3500°K lamp (shipped
separately)
LRC7 Provides compatibility with
Lithonia Reloc System. Reloc
System can be installed less
this option with connectors
provided by others. Access
above ceiling required
8
CP Chicago Plenum
CSA CSA Certified
BDP 9 Ballast disconnect plug
ELHL 6 High lumen output
emergency battery pack.
Integral test switch provided
6
ELRHL High lumen output
emergency battery pack.
Remote test switch provided
10
NSD Sensorswitch nLightTM
dimming relay
Accessories
Order as separate catalog number.
SCA8 Sloped ceiling adapter.
Degree of slope must be
specified (10D, 15D, 20D,
25D, 30D). Ex: SCA8 10D
AF 8 TRT OPEN
DCF-180
8" AF Open Reflector
Distribution curve
Distribution data
Output data
Coefficient of utilization
Illuminance Data at 30" Above Floor for
a Single Luminaire
AF 1/32TRT 8AR, (1) CF32DT/E/IN/835, 2400 lumens per lamp, 1.3 s/mh, Test no. LTL9452
From 0°
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
cp.
1005
1053
1140
1105
768
622
42
11
9
8
0
Lumens
95
275
416
405
354
46
11
10
8
Zone
Lumens %lamp
0°-30° 785.7
0°-40° 1190.3
0°-60° 1590.4
0°-90° 1619.7
90°-180° 0.0
0°-180° 1619.7
32.7
49.6
66.3
67.5
0.0
67.5*
*Efficiency
ρf
20%
ρc
80%
70%
50%
ρw 50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
74
67
62
56
52
48
44
41
38
35
72
64
57
52
47
43
39
36
33
31
72
66
61
56
51
47
43
40
37
35
70
63
57
51
47
43
39
36
33
30
69
64
59
54
50
46
43
39
37
34
68
61
56
50
46
42
38
35
33
30
Initial fc
Mount at beam
height center
8'
10'
12'
14'
16'
33.2
17.9
11.1
7.6
5.5
50%
10%
beam angle 61.0° beam angle 94.7°
fc at
fc at
Beam beam
Beam
beam
diameter edge
diameter edge
6.5
8.8
11.2
13.5
15.9
16.6
8.9
5.6
3.8
2.8
11.9
16.3
20.6
25.0
29.3
3.3
1.8
1.1
0.8
0.6
AF 1/42TRT 8AR, (1) CF42DT/E/IN/835, 3200 lumens per lamp, 1.3 s/mh, Test no. LTL9455
From 0°
cp.
Lumens
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
1295
1303
1437
1347
998
848
42
4
1
0
0
122
373
588
570
464
49
4
1
0
Zone
Lumens %lamp
0°-30° 1083.2
0°-40° 1653.4
0°-60° 2166.3
0°-90° 2171.7
90°-180° 0.0
0°-180° 2171.7
33.8
51.7
67.7
67.9
0.0
67.9*
*Efficiency
ρf
20%
ρc
80%
70%
50%
ρw 50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
74
68
62
57
53
49
45
41
38
36
72
65
59
53
48
44
40
37
34
31
73
67
61
56
52
48
44
41
38
36
71
64
58
52
48
43
40
37
34
31
70
65
60
55
51
47
43
40
37
35
69
62
57
51
47
43
39
36
33
31
Initial fc
Mount at beam
height center
8'
10'
12'
14'
16'
42.8
23.0
14.3
9.8
7.1
50%
10%
beam angle 64.5° beam angle 94.8°
fc at
fc at
Beam beam
Beam
beam
diameter edge
diameter edge
6.9
9.5
12.0
14.5
17.0
21.4
11.5
7.2
4.9
3.6
12.0
16.3
20.7
25.0
19.3
4.3
2.3
1.4
1.0
0.7
AF 2/32TRT 8AR, (2) CF32DT/E/IN/835, 2400 lumens per lamp, 1.4 s/mh, Test no. LTL9407
From 0°
cp.
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
1584
1676
1720
1849
1348
830
36
5
2
0
0
Lumens
165
514
795
815
549
63
6
2
0
Zone
Lumens %lamp
0°-30° 1473.7
0°-40° 2288.7
0°-60° 2901.1
0°-90° 2909.7
90°-180° 0.0
0°-180° 2909.7
30.7
47.7
60.4
60.6
0.0
60.6*
*Efficiency
ρf
20%
ρc
80%
70%
50%
ρw 50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
66
61
56
51
47
44
40
37
35
32
65
58
52
48
43
39
36
33
31
28
65
60
55
51
47
43
40
37
34
32
64
57
52
47
43
39
36
33
30
28
63
58
53
49
46
42
39
36
34
31
61
56
51
46
42
39
35
33
30
28
Initial fc
Mount at beam
height center
8'
10'
12'
14'
16'
52.4
28.2
17.6
12.0
8.7
50%
10%
beam angle 67.9° beam angle 94.3°
fc at
fc at
Beam beam
Beam
beam
diameter edge
diameter edge
7.4
10.1
12.8
15.5
18.2
26.2
14.1
8.8
6.0
4.3
11.9
16.2
20.5
24.8
29.1
5.2
2.8
1.8
1.2
0.9
AF 2/42TRT 8AR, (2) CF42DT/E/IN/835, 3200 lumens per lamp, 1.4 s/mh, Test no. LTL9406
From 0°
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
cp.
Lumens
2211
2248 225
2270 707
2205 1097
1699 1137
1092 749
47
84
7
8
3
3
0
0
0
Zone
Lumens %lamp
0°-30° 2029.5
0°-40° 3166.3
0°-60° 3999.6
0°-90° 4009.9
90°-180° 0.0
0°-180° 4009.9
*Efficiency
31.7
49.5
62.5
62.7
0.0
62.7*
ρf
20%
ρc
80%
70%
50%
ρw 50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
69
63
58
53
49
45
42
39
36
33
67
60
54
49
45
41
37
34
32
29
67
62
57
52
48
45
41
38
36
33
66
59
54
49
44
40
37
34
31
29
65
60
55
51
47
44
40
37
35
33
64
58
52
48
44
40
37
34
31
29
Initial fc
Mount at beam
height center
8'
10'
12'
14'
16'
73.1
39.3
24.5
16.7
12.1
50%
10%
beam angle 67.6° beam angle 94.1°
fc at
fc at
Beam beam
Beam
beam
diameter edge
diameter edge
7.4
10.0
12.7
15.4
18.1
36.5
19.7
12.2
8.4
6.1
11.8
16.1
20.4
24.7
29.0
7.3
3.9
2.4
1.7
1.2
ENERGY (Calculated in accordance with NEMA standard LE-5A)
Annual*
Energy
Cost
LER.DOL
$5.44
44
$5.08
47
$5.93
40
$5.92
41
(1)
(1)
(2)
(2)
Lamps
32W TRT
42W TRT
32W TRT
42W TRT
Lamp
Lumens
2400
3200
4800
6400
Ballast
Factor
0.98
1.00
0.96
0.95
Input
Watts
36
46
69
94
* Comparative yearly lighting energy cost per 1000 lumens
NOTES:
1
For electrical characteristics, refer to Technical Bulletins tab.
2
Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field
measurements. Dimensions and specifications are based on the most current available data and are subject to change without notice.
3
Consult factory or IES file for microgroove baffle, black cone and other photometric reports.
DCF-180
©2003, 2009, 2011 Acuity Brands Lighting, Inc.
Catalog
Number
Notes
FEATURES & SPECIFICATIONS
INTENDED USE — RT5 is designed for applications that require the extremely energy efficient delivery of
comfortable volumetric light from a lay-in fixture that is appealing and shallow in depth. Ideal for offices, schools,
hospitals, retail and numerous other commercial applications. Certain airborne contaminants can diminish
integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses.
CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer light-diffusing film.
Rugged, one-piece, cold-rolled steel reflector with embossed facets. Polyester powder paint after fabrication.
Rigid structure with ballast box and endplates with integral T-bar clips.
Fixtures may be mounted end-to-end.
OPTICS — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal
amount to walls, cubicles, work surfaces and people.
Luminous characteristics are carefully managed at high angles, providing just enough intensity to deliver the
volumetric effect.
Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector
with light.
Linear faceted reflector softens and distributes light into the space and minimizes the luminance ratio between
the fixture and the ceiling.
Mechanical cut-off across the reflector and fresnel refraction along the refractor provide high angle shielding
and a quiet ceiling.
Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth.
ELECTRICAL — Highly efficient program-start electronic ballasts, Class P, thermally protected, resetting, HPF,
non-PCB, UL Listed, CSA Certified, sound rated A. Your choice of Premium or Premium XP T5 lamp with enhanced
phosphors and 85 CRI. Ballast/lamp efficacy up to 100+ LPW. Lamp is TCLP compliant.
0.90 or 0.95 ballast factor standard for typical applications. 1.15 ballast factor or F54T5HO lamping available
for higher ceiling height applications.
Step-level dimming option allows system to be switched to 50% power for compliance with common energy
codes while maintaining fixture appearance.
S5 option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming. See
SYNERGY® Lighting Controls specification sheets for more information. Ballast Disconnect provided standard
where required to comply with U.S. and Canadian electrical codes.
INSTALLATION — Side mounted ballast tray accessed by removing adjacent ceiling tile. Ballast tray may be
removed from fixture during service.
Lamps accessed by squeezing refractor to release from retention tabs.
LISTING — UL Listed (standard). Optional: Canada CSA or cUL. Mexico NOM.
WARRANTY — Fixture guaranteed for one year against mechanical defects in manufacture. Lamp and ballast
system warranty (24 months for lamp, 60 months for ballast) by lamp and ballast manufacturer.
ORDERING INFORMATION
Type
2RT5
2'X 4'
2 Lamps
Premier or Premier XP T5
Specifications
Length: 48 (121.8)
Width: 24 (61.0)
Depth: 3-1/8 (7.9)
3-1/8
(7.9)
24
(61.0)
All dimensions are inches (centimeters) unless otherwise specified.
Protected by one or more of US Patents Nos. 7,229,192; D541,467; D541,468; D544,633; D544,634; D544,992;
D544,933 and additional patent pending.
Specifications subject to change without notice.
Example: 2RT5 28T5 MVOLT GEB95 LPM835P
For shortest lead times, configure products using bolded options.
2RT5
Series
2RT5 Recessed T5
Lamp type
28T5 28W T5 (46")
54T5HO 54W T5 (46")1
Voltage
MVOLT
3473
2
Ballast
Options
Lamp7
GEB95
GEB95S
GEB115
.95 ballast factor
.95 ballast factor, step dimming4
1.15 ballast factor
GEB115S
1.15 ballast factor, step dimming
GEB10PS
1.0 ballast factor, program start5
S5
GEB80
.95 ballast factor SIMPLY5TM
system6
.80 ballast factor1
GEB80S
.80 ballast factor, step dimming1
GEB90
.90 ballast factor
GEB90S
.90 ballast factor, step dimming
GEB10PS
1.0 ballast factor, program start4
LPM835P Premier 3500° K
28W lamp8
LPM830P Premier 3000° K
28W lamp8
LPM841P Premier 4100° K 28W
lamp8
L835XP
Premier XP 3500° K
28W lamp8
L830XP
Premier XP 3000° K
28W lamp8
L841XP
Premier XP 4100° K
28W lamp8
LP835
3500° K 54W lamp
LP830
3000° K 54W lamp
LP841
4100° K 54W lamp
Notes
1 For T5HO applications, use GEB10PS, GEB80 or GEB80S ballast.
2 MVOLT (120-277 volts), 50-60HZ.
3 For 347V, use GEB95S or GEB10PS.
4 Only option for 347V.
5 Not available with 28T5.
6 SIMPLY5 includes 13' S5 SSC RELOC® wiring system, specify
7
8
9
10
11
12
GLR
Internal fast-blow fuse9
PWS1836 6' prewire, 3/8" diameter,
18-gauge, 3-wire (n/a with step
dimming)10
PWS1846 6' prewire, 3/8" diameter,
18-gauge, 4-wire11
EL14
Emergency battery pack12
EL65
Emergency battery pack12
HW
Hardware for SIMPL5 system;
replaces RELOC®
CSA
Listed and labeled to comply
with Canadian standards
BDP
Ballast disconnect plug (meets
codes that require in-fixture
disconnect)
voltage unless HW (hardwire) or PWS is ordered.
Required. All fixtures shipped with lamps installed.
28T5 lamp type only.
Must specify voltage, 120 or 277.
For use with standard ballast.
For use with step dimming ballast.
See PS1400QD spec sheet for EL lumen output information.
FLUORESCENT2 RT5-2X4
2RT5 Volumetric Recessed Lighting 2' x 4'
2RT5 28T5 GEB95 LPM835P, (2) FP28/835/PM/ECO lamps, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL13260
300
70˚
600
50˚
900
1200
1500
1800
10˚
30˚
CP Summary
0˚
90
0˚ 1770 1770
5˚ 1766 1750
15˚ 1695 1707
25˚ 1555 1623
35˚ 1339 1473
45˚ 1044 1280
55˚ 695 1071
65˚ 393
715
75˚ 179
257
85˚ 30
21
90
0
0
Coefficients of Utilization
pf
20%
pc
80%
70%
50%
pw 70%50%30% 50%30%10% 50%30%10%
0 107 107 107 105 105 105 100 100 100
1 98 94 91
92 89 86
88 86 83
2 89 82 76
81 75 70
77 73 69
3 82 72 65
71 64 59
68 63 58
4 75 64 56
63 56 50
61 54 49
5 69 57 49
56 49 43
54 48 43
6 63 52 44
51 43 38
49 42 37
7 59 47 39
46 39 33
45 38 33
8 55 43 35
42 35 30
41 34 30
9 51 39 32
39 32 27
38 31 27
10 48 36 29
36 29 24
35 28 24
RCR
90˚
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0˚ - 30˚
1383
25.3
28.2
0˚ - 40˚
2264
41.5
46.1
0˚ - 60˚
3976
72.8
81.0
0˚ - 90˚
4908
89.9
100.0
90˚ - 180˚
0
0.0
0.0
0˚ - 180˚
4908
89.9
100.0
LER: 80.4 lpw
Efficiency: 89.9%
0˚
90˚
*The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported
lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration.
Input Wattage
Ballast120/277
GEB90
GEB90S
GEB90S
@50% power mode
55/54
27
GEB95
GEB95S
60/58
GEB95S
@50% power mode
28/28
GEB115
GEB115S
73/71
GEB115S
@50% power mode
35/35
GEB80
GEB80S
96/93
GEB80S
@50% power mode
52/51
S5
60/58
T5/T8 Energy Comparison
System
3-lamp T8
2RT5 2-lamp T5
2RT5 2-lamp T5
2RT5 2-lamp T5
Lamp
Type
Ballast
Factor
Input
Watts
Watts Saved
Compared to T8
F32T8
F28T5XP
F28T5
F28T5
0.88
0.90
0.95
1.15
88
54
58
71
–
34
30
17
2RT5-2X4
FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com
©2010 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/20/10
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
ATTRIBUTES
Slim, low-profile housing for ceiling or wall mounting. Matches AW Series in
appearance.
Choice of flat-bottom diffusers –– prismatic acrylic or matte white opal
acrylic. Both available in high-impact versions. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses.
Diffuser hinges open from either side for easy cleaning and servicing.
For surface or stem mounting, individual or row installation.
Available in tandem-wired lengths.
Guaranteed for one year against mechanical defects in manufacture.
CONSTRUCTION
Housing formed from cold-rolled 20-gauge steel. End plates welded to
housing. Standard product complies with NYC requirements; no options
necessary. No asbestos is used in this product.
Thermally protected, resetting, Class P, HPF, non-PCB, UL listed, CSA certified ballast is standard. Ballasts are sound rated A. Standard combinations
are CBM approved and conform to UL 935.
FINISH
High-gloss, baked white enamel finish. Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts
finished with high-gloss, baked white enamel.
ELECTRICAL SYSTEM
Fixture conforms to UL 1570 and is suitable for damp locations. AWM, TFN or
THHN wire used throughout, rated for required temperatures.
ENERGY
Luminaire Efficacy Rating (LER) and Annual Energy Cost:
Two-lamp LER.FW = 62. Annual Energy Cost = $3.87.
Based on 32W T8 lamp, 2850 lumens, and energy-saving electronic ballast.
Ballast factor = .88, input watts = 61.
Corridor Acrylic Wraparound
CA
2', 3', 4' and 8' Length
1 or 2 Lamps
Calculated in accordance with NEMA standard LE-5.
LISTING
UL listed to US and Canadian safety standards (see Options). NOM Certified
(see Options).
Specifications subject to change without notice.
Lead times may vary depending on options selected. Consult with your sales representative.
Example: CA 2 32 MVOLT GEB10IS
ORDERING INFORMATION
Series
CA Corridor
wraparound
For tandem doublelength unit, add prefix T.
Example: TCA
Number of
lamps
1
2
Not included.
Lamp type
17
25
28
32
17W T8 (24")
25W T8 (36")
28W T5 (46-1/2")1
32W T8 (48")
Diffuser
Voltage
Options
(blank) Prismatic
AR High-impact
prismatic
ACW Matte white
AWR High-impact
matte white
347
MVOLT2
GEB10IS Electronic ballast, <10% THD,
instant start
GEB10PS Electronic ballast, <10% THD,
program start
EL Emergency battery pack
(nominal 300 lumens; see Life
Safety Section)
GLR Internal fast-blow fuse3
GMF Internal slow-blow fuse3
RIF1 Radio interference filter (1 per
fixture)
CSA Listed and labeled to comply with
Canadian Standards
NOM NOM Certified
Others
available.
Accessories
Notes
1
2
3
All T5 lamp types use GEB10PS ballasts only.
Electronic ballast operates 120V through 277V.
Specify voltage.
Fluorescent
Order as separate item.
SQ
1B
DSH24
Swivel-stem hanger (specify in 2" increments)
Ceiling spacer (adjusts from 1-1/2" to 2-1/2" from
ceiling)
Double-stem hanger for 4' fixtures, 24" stems
Sheet #: CA
WRAP-120
CA Corridor Acrylic Wraparound
MOUNTING DATA
DIMENSIONS
For unit or row installation, surface or stem mounting. Stem mounting not
available on TCB units.
Inches (millimeters). Subject to change without notice.
Individual installation — One double-stem (4' only) or two single-stem
hangers required.
Row installation — One hanger per fixture plus one per row required.
See ACCESSORIES below for hanging devices.
DSH
C = 7/8 (22) Dia.K.O.
D = 11/16 (17) Dia. K.O.
E = 2 (51) Dia. K.O. and
7/8 (22) Dia. K.O.
F = 7/16 (11) Dia.K.O.
J = 11/16 x 1 (17 x 25) K.O.
N = 5/16 (8) Dia. hole
P = 5/16 x 3/4 (8 x 19) K.O.
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp
configurations shown are typical. Full photometric data on these and other configurations available upon request.
CA 2 32
Report LTL 6020 – Lumens per lamp = 2900
S/MH (along) 1.2 (across) 1.5
Coefficient of Utilization
Ceiling
80%
70%
50%
Wall
70% 50% 30%
70% 50% 30%
50% 30% 10%
0%
0
1
2
3
4
5
6
7
8
9
10
87
78
71
65
59
54
50
46
42
39
36
83
75
68
62
56
52
47
44
40
37
35
77
66
57
51
45
40
36
32
29
26
24
64
51
42
36
30
26
22
19
17
14
12
87
774
64
57
50
44
39
35
32
29
26
87
70
59
50
43
37
33
29
25
22
20
83
71
62
54
48
43
38
34
31
28
25
83
68
57
49
42
36
32
28
25
22
19
77
63
53
46
40
34
30
27
23
21
18
0%
77
61
50
42
36
30
26
23
20
17
15
Zonal Lumens Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens %Lamp %Fixture
886
1481
2627
3696
654
4350
15.3
25.5
45.3
63.7
11.3
75.0
20.4
34.0
60.4
85.0
15.0
100.0
Lithonia Lighting
Sheet #: CA
©1996-2010 Acuity Brands Lighting, Inc., All rights reserved. Rev. 4/1/10
Fluorescent
One Lithonia Way, Conyers, GA 30012
Phone: 800-858-7763 Fax: 770-929-8789
www.lithonia.com
Catalog
Number
Notes
FeatureS & specifications
INTENDED USE — Suitable for cold weather (down to -40oC), wet location, security/prisons and highabuse applications.
Type
CONSTRUCTION — Durable cast aluminum construction – rugged, low-profile housing is .250 to .525"
thick.
NEMA 4X option available for wet and hose-down applications.
Clear, UV-stable polycarbonate cover is .130" thick to prevent cracking or breaking. Cover is secured with
four stainless steel, Torx T20 tamperproof screws with center pin.
All-Conditions Exits
Polycarbonate faceplate incorporates universal directional chevron knockouts that are concealed and easily
removed and replaced.
LV
Universal mount (UM) option available – top, back, end mounting or conduit entry (canopy provided).
Letters 6" high with 3/4" stroke, with 100 ft viewing distance rating.
U.S. Patent No. 5,611,163 and D383,501.
OPTICS — Lamp is constructed using new LED technology. Provides perfectly uniform illumination.
White on white
w/red letter color
Expected LED life of up to 10 years, based on continuous operation. Single-face exit uses one LED lamp;
double-face exit uses two LED lamps.
Low energy consumption — red lamp consumes 2.3W (120V); green lamp consumes 1.7W (120V).
LED LAMPS
NEMA 4X Rating Available
INSTALLATION — Universal and back (no canopy) mount available.
Conduit entry (1/2" - 14 UNC) included with universal mounting.
Cast-aluminum canopy attaches to 10-gauge steel mounting plate for top or end mounting (not required
for back mounting).
Canopy mounting bracket provides 160 lbs. of mounting strength when mounted to suitable structure.
Bracket will only fit a 2-gang junction box.
LISTINGS — UL listed. Listed and labeled to comply with Canadian Standards C-860 and C22.2 No. 9 (see
Options). 4X option is UL listed to NEMA 4X ratings. Meets UL 924, NFPA 101 (current Life Safety Code), NEC
and OSHA illumination standards, and State of Minnesota energy-efficient legislation requiring less than
20W consumption.
Black on black
w/green letter color
WARRANTY — Five-year total customer satisfaction warranty on exit, including lamp.
All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and
tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to p erform the
required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.
Ordering information
LV
Example: LV S W 1 R 120/277
For shortest lead times, configure products using bolded options.
S
Family Face type
Faceplate/housing color
Number of faces
Letter color Input voltage
Mounting
LV
(blank) Black faceplate
on black housing
W
White on white
WB
White on black
BW
Black on white
AB
Aluminum on
black1
AW
Aluminum on
white1
1
2
R
G
(blank)
UM
S Stencil
Single face
Double face2
Red
Green1
120/277 Dual
voltage1
120/347 Dual
voltage3
Options
Back mount
Universal
mount
4
(Blank)
F1
X2
None
Fire alarm flashing interface1
Primary and secondary AC inputs
provided1,5,6
DL
UL listed for damp locations
4X
UL listed for NEMA 4X1
LDC6
6V DC input for LED lamps3
LDC12/48 12V-48V DC input for LED lamps3
CSA
Listed and labeled to comply with Canadian
Standards
Notes
Accessories: Order as separate catalog number.
ELA TPS T20
emergencY
Torx tamperproof bit for T20 center-pin screw
1
2
3
4
5
6
Not available with CSA option.
Available with universal mount only.
Only available with CSA option.
Back mount standard with single face unless UM is specified. Not available on double face.
UL listed as emergency lighting equipment.
Must specify input voltage (120 or 277V). Not available dual voltage.
LV_e
LV LED, Extreme
specifications
Mounting
All dimensions are in inches (centimeters).
Shipping weight: 11 lbs. (5 kgs.)
ELECTRICAL
Primary Circuit
Type
Rated
LED life1
Supply
voltage
Red
10 years
120
Red
10 years
277
Red
10 years
347
Green
10 years
120
Green
10 years
277
Number of
lamps2
1
2
1
2
1
2
1
2
1
2
Input
watts
2.3
4.6
2.2
4.4
1.12
3.16
1.7
2.8
1.9
3.3
End Mount
Max.
amps
.15
.30
.13
.26
.29
.29
.087
.081
.089
.086
6
(15.2)
8.5
(21.6)
13-7/8
(35.2)
15
(38.1)
Notes
1 Based on continuous operation.
2 Two-lamp version available with double-face only.
Back Mount
13-7/8
(35.2)
8-3/4
(22.2)
Supplemental Emergency Circuit
Type
No. of faces
Nominal lamp voltage
Electrical watts
Input amps
LDC6
1
6
1.44
.24
LDC12/48
1
12
1.9
.15
LDC12/48
1
24
1.8
.07
LDC12/48
1
32
1.8
.06
LDC12/48
1
48
1.7
.04
LDC6
2
6
2.9
.48
LDC12/48
2
12
3.1
.26
LDC12/48
2
24
3.1
.13
LDC12/48
2
32
3.3
.10
LDC12/48
2
48
3.4
.0
4
(10.2)
4-3/8
(11.1)
4-3/4
(12.1)
9-1/2
(24.1)
Top Mount
Top Mount
Single-FaceDouble-Face
6
(15.2)
9-7/8
(24.9)
Key FeatureS
3
(7.6)
4-1/4
(10.8)
NEMA 4X
Mounting Plate
4-3/8
(11.1)
Unique LEDs provide extremely long life and low
energy consumption.
UL and CSA approved for damp or NEMA4X wet
locations (see options). Cold weather — down
to -40oC.
4-3/8
(11.1)
Housing or canopy mounting bracket should be attached to mounting surface using suitable fastener for type of wall
material. All four mounting hole positions should be used, and anchors or screws should have a minimum pullout rating of
160 lbs. Bracket will only fit a 2-gang junction box.
Lv_e
EMERGENCY:
One Lithonia Way
Conyers, GA 30012
Phone: 800-334-8694
Fax: 770-981-8141
www.lithonia.com
© 1996-2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/16/11
Catalog
Number
Notes
FEATURES & SPECIFICATIONS
INTENDED USE — RT5™ is designed for applications that require the extremely energy efficient delivery of
comfortable volumetric light from a lay-in fixture that is appealing and shallow in depth. Ideal for offices,
schools, hospitals, retail and numerous other commercial applications. Certain airborne contaminants
can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for
suitable uses.
OPTICS — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal
amount of light to walls, cubicles, work surfaces and people.
Luminous characteristics are carefully managed at high angles to deliver just enough intensity to deliver the
volumetric effect.
Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector
with light.
Linear faceted reflector softens and distributes light into the space and minimizes the luminance ratio between
the fixture and the ceiling.
Mechanical cut-off across the reflector and fresnel refracton along the refractor provide high angle shielding
and a quiet ceiling.
Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth.
CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer light diffusing film.
Rugged, one-piece, cold-rolled steel reflector with embossed facets with polyester powder paint after
fabrication.
Rigid structure with ballast box and endplates with integral T-bar clips.
Fixtures may be mounted end-to-end.
ELECTRICAL — Highly efficient program start electronic ballasts, Class P, thermally protected, resetting, HPF,
non PCB, UL Listed, CSA Certified, sound rated A. Your choice of Premium or Premium XP T5 lamp with enhanced
phosphors and 85 CRI. Lamp is TCLP compliant.
S5 option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming. See
SYNERGY® Lighting Controls specification sheets for more information. Ballast Disconnect provided standard
where required to comply with U.S. and Canadian electrical codes.
INSTALLATION — Side mounted ballast tray accessed by removing adjacent ceiling tile. Ballast tray may be
removed from fixture during service.
Lamp accessed by squeezing refractor to release from retention tabs.
LISTING — UL Listed (standard). Optional: Canada CSA or cUL. Mexico NOM.
WARRANTY — Fixture guaranteed for one year against mechanical defects in manufacture. Lamp and ballast
system warranty (24 months for lamp, 60 months for ballast) by lamp and ballast manufacturer.
Protected by one or more of US Patents Nos. 7,229,192; D541,467; D541,468; D544,633; D544,634; D544,992;
D544,933 and additional patent pending.
Type
RT5
1’x 4’
One or Two Lamps
Premier and Premier XP T5
Specifications
Length: 48 (121.8)
Width: 12 (30.5)
Depth: 3-1/8 (7.9)
All dimensions are inches (centimeters) unless otherwise specified.
Note: Specifications subject to change without notice.
ORDERING INFORMATION
RT5
Series
RT5 Recessed
T5
FLUORESCENT
Example: RT5 1 28T5 MVOLT GEB10PS LPM835P
For shortest lead times, configure products using bolded options.
28T5
Number
of lamps
1
2
Lamp type
28T5
28W T5
(46")
54T5HO 54W
T5HO
(46")1
Voltage
MVOLT
3473
Ballast
2
Lamp6
GEB10PS 1.0 ballast factor,
program start4
GEB95
.95 ballast factor (2-lamp)
GEB95S
S5
.95 ballast factor, step
dimming(2-lamp only)
SIMPLY5TM system5
GEB80
.80 ballast factor1
GEB80S
.80 ballast factor, step dimming1
GEB115
1.15 ballast factor (2-lamp only)
GEB115S
GEB90
1.15 ballast factor (2-lamp only),
step dimming
.90 ballast factor
GEB90S
.90 ballast factor, step dimming
Options
LPM835P Premier 3500°K lamp
LPM830P
Premier 3000°K lamp
LPM841P
Premier 4100°K lamp
L835XP
LP835
Premier 3500°K 28W
lamp
Premier 3000°K 28W
lamp
Premier 4100°K 28W
lamp
3500°K, 54W lamp
LP830
3000°K, 54W lamp
LP841
4100°K, 54W lamp
L830XP
L841XP
GLR
Internal fast-blow fuse7
PWS1836 6' prewire, 3/8" diameter, 18-gauge,
3-wire (n/a with GEB95S)8
PWS1846 6' prewire, 3/8" diameter,
18-gauge, wire9
EL14
Emergency battery pack10
CSA
Listed and labeled to comply with
Canadian standards
QFC_
Quick-flex cable7
BDP
Ballast disconnect plug (meets
codes that require in-fixture
disconnect)
Notes
1 For T5HO applications, use GEB10PS, GEB80 or GEB80S ballasts.
2 MVOLT (120-277 volts), 50-60HZ.
3 For 347V use GEB95S or GEB10PS ballast only.
4 GEB10PS for use with one-lamp 28T5, and one- and two-lamp
54T5HO.
5 SIMPLY5 includes 13’ S5 SSC RELOC® wiring system, specify
voltage unless HW (hardwire) or PWS is ordered. Two-lamp =
.95 ballast factor; one-lamp = 1.0 ballast factor.
6
Required. All fixtures shipped with lamps
installed.
7 Must specify voltage, 120 or 277.
8 For use with standard ballast.
9 For use with step dimming ballast.
10 See PS1400QD spec sheet for EL lumen
output information.
RT5-1X4
RT5 Volumetric Recessed Lighting, 1' x 4'
RT5 28T5 GEB10PS LPM835P, (1) FP28/835/PM/ECO lamp, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL13316
100
70˚
200
300
400
50˚
500
600
700
800
10˚
0˚
30˚
CP Summary
0˚ 90
0˚ 862 862
5˚ 848 862
15˚ 814 844
25˚ 747 792
35˚ 636 723
45˚ 492 636
55˚ 331 523
65˚ 189 323
75˚ 85 106
85˚ 15 13
0
90 0
Coefficients of Utilization
pf
20%
pc
80%
70%
50%
pw 70%50%30% 50%30%10% 50%30%10%
0 104 104 104 101 101 101 97 97 97
1 95 91 88
89 86 83
86 83 81
2 87 80 74
78 73 68
75 71 67
3 79 70 63
69 62 57
66 61 56
4 72 62 55
61 54 49
59 53 48
5 67 56 48
55 47 42
53 46 42
6 62 50 42
49 42 37
48 41 36
7 57 45 38
45 37 32
43 37 32
8 53 41 34
41 34 29
40 33 29
9 50 38 31
37 31 26
36 30 26
10 46 35 28
35 28 24
34 28 23
RCR
90˚
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0˚ - 30˚
672
24.6
28.3
0˚ - 40˚
1100
40.3
46.3
0˚ - 60˚
1940
71.1
81.7
0˚ - 90˚
2375
87.0
100.0
90˚ - 180˚
0
0.0
0.0
0˚ - 180˚
2375
87.0
100.0
LER: 74.2 lpw
Efficiency: 87.0%
90˚
RT5 2 28T5 GEB95S LPM835P, (2) FP28/835/PM/ECO lamp, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL14100
LER: 69.1 lpw
*The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported
lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration.
RT5-1X4
FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com
©2004-2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 1/10/11
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Specification premium, high performance, static T8 luminaires provide
general illumination for recessed applications; ideal for restricted plenum
spaces.
Specification Premium T8 Troffer
SP8 2'x4'
ATTRIBUTES
Designed exclusively for use with T8 lamps, electronic ballasts and sockets.
CONSTRUCTION
Smooth hemmed sides and smooth, inward formed end flanges for safe
handling. Lighter weight fixture allows safe, easy installation.
Standard steel door frame has superior structural integrity with premium
extruded appearance and precision flush mitered corners. Steel door allows
easy lens replacement without frame disassembly (for lenses up to .156"
thick). Powder-painted, steel latches provide easy, secure door closure.
2, 3, 4 or 6 Lamps
T8
Superior mechanical light seal requires no foam gasketing. Integral T-bar clips
secure fixture to T-bar system. Housing formed from cold-rolled steel. Acrylic
shielding material 100% UV stabilized. No asbestos is used in this product.
US PATENTS: 6,210,025; 6,231,213; 6,213,625; 2,288,471.
FINISH
Five-stage iron-phosphate pretreatment ensures superior paint adhesion and
rust resistance. Painted parts finished with highly reflective matte white enamel.
OPTICAL
A12 lens features reverse apex technology for superior lamp obscuration
and improved visual comfort.
ELECTRICAL SYSTEM
Standard ballast is electronic, thermally protected, resetting, Class P, HPF,
non-PCB, UL Listed, CSA certified ballast, universal voltage and sound rated A.
Luminaire is suitable for damp locations. AWM, TFN or THHN wire used
throughout, rated for required temperatures.
LISTING
Standard: UL. Optional: Canada — CSA or cUL; Mexico — NOM.
WARRANTY
Specifications
Length: 48 (1218)
Width: 24 (609)
Depth: 3-11/16 (94)
Weight: 22 lbs (9.9 kg)
All dimensions are inches (millimeters).
Guaranteed for one year against mechanical defects in manufacture.
Specifications subject to change without notice.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: 2SP8 G 3 32 A12 MVOLT 1/3 GEB10IS
2SP8
Series
2SP8 2' wide
Number
of lamps
2
3
4
Voltage
Options 1
(blank) Flush steel, white
FN Flush aluminum, natural
FM Flush aluminum, matte black
120
277
347
FW Flush aluminum, white
MVOLT
1/4 One 4-lamp ballast
1/3 One 3-lamp ballast
GEB10IS Electronic ballast, <10% THD, instant
start
GEB10RS Electronic ballast, <10% THD, rapid
start
EL Emergency battery pack (nominal 300
lumens
EL14 Emergency battery pack (nominal
1400 lumens)
Door frame
6
Not
included.
RN Regressed aluminum, natural
RM Regressed aluminum, matte black
RW Regressed aluminum, white
Trim type
Lamp type
G Grid
F Overlapping
flanged
32 32W T8 (48")
Diffuser type
A12 #12 pattern acrylic, reverse
apex
A12125 #12 pattern acrylic, .125" thick
RA125 #12 pattern acrylic, .125" thick,
reverse apex
A19 #19 pattern acrylic, .156" thick
A15
PC1S
PC2S
NOTE:
1 MVOLT standard for 120-277V applications,
50-60 hz operation. Some options require
voltage specified.
Fluorescent
Others
available.
PC3S
#15 pattern acrylic, .2" thick
1/2" x 1/2" x 1/2" plastic cube
louver, silver
1-1/2" x 1-1/2" x 1" plastic cube
louver, silver w/ flange
3/4" x 3/4" x 1/2" plastic cube
louver, silver
GLR Internal fast-blow fuse
GMF Internal slow-blow fuse
LST Tandem-wired fixture pairs (shared
ballasts)
PWS1836 6' prewire, 3/8" dia., 18-gauge, 1 circuit
PWS1846 6' prewire, 3/8" dia., 18-gauge, 2 circuits
LP735 Lamped, 700-series, 3500K
LP__ Lamped; specify lamp type and color
JP Palletized and stretch-wrapped
without individual cartons
CSA CSA Certified
NOM NOM Certified
Sheet #: SP8-2x4
STAT-150
SP8 2'x4' Static T8 Troffer
MOUNTING DATA
DIMENSIONS
Continuous row mounting of flanged units requires CRE and CRM trim options (see
Options).
NOTE:
1 Recommended rough-in dimensions for F-trim fixtures 24"x48". (Tolerance is +1/4"-0".)
Swing-gate range 1-3/16" to 3-15/16". Swing-gate span 23-3/8" to 26-11/16". Fixture
swing-gate points require additional 9/16" over nominal fixture height.
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%.
Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request.
2SP8 2 32 A12*
Report LTL 7525
Lumens per lamp - 2850 – Lum. eff. - 85.5%
S/MH (along) 1.3 (across) 1.4
Coefficient of Utilization
2SP8 3 32 A12*
Report LTL 7492
Lumens per lamp - 2850 – Lum. eff. - 83.6%
S/MH (along) 1.3 (across) 1.4
Coefficient of Utilization
2SP8 4 32 A12*
Report LTL 7526
Lumens per lamp - 2850 – Lum. eff. - 81.5%
S/MH (along) 1.2 (across) 1.4
Coefficient of Utilization
Ceiling
80%
Wall 70% 50% 30%
70%
70% 50% 30%
50%
50% 30% 10%
Ceiling
80%
Wall 70% 50% 30%
70%
70% 50% 30%
50%
50% 30% 10%
Ceiling
80%
Wall 70% 50% 30%
70%
70% 50% 30%
50%
50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
99
92
84
77
71
66
61
57
53
49
46
95
85
75
67
60
54
49
45
41
38
35
0
1
2
3
4
5
6
7
8
9
10
97
90
82
76
70
64
60
56
52
49
46
93
83
74
66
59
53
49
44
41
38
35
0
1
2
3
4
5
6
7
8
9
10
95
87
80
74
68
63
58
54
51
47
44
91
81
72
64
58
52
47
43
40
37
34
102
94
86
79
73
67
62
58
54
51
47
102
90
80
71
63
57
52
47
43
39
36
102
87
74
64
56
50
44
40
36
33
30
99
88
78
70
62
56
51
46
42
39
36
99
85
73
64
56
49
44
40
36
33
30
95
82
71
62
55
48
43
39
35
32
29
95
80
68
58
50
44
39
34
31
28
25
Zonal Lumens Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens %Lamp
1541
2571
4192
4874
0
4874
27.0
45.1
73.5
85.5
0
85.5
100
92
84
78
72
66
61
57
53
50
47
100
88
78
70
62
56
51
46
42
39
36
100
85
73
63
55
49
44
39
36
32
30
Zone
31.6
52.7
86.0
100.0
0
100.0
LAMP
97
83
72
62
55
49
43
39
35
32
29
Zonal Lumens Summary
%Fixture
0-30
0-40
0-60
0-90
90-180
0-180
Lumens %Lamp
2319
3833
6164
7147
0
7147
27.1
44.8
72.1
83.6
0
83.6
Energy (Calculated in accordance with NEMA standard LE-5)
ANNUAL
97
86
77
68
61
55
50
46
42
38
36
LAMP
%Fixture
32.4
53.6
86.2
100.0
0
100.0
93
80
70
61
54
48
43
38
35
32
29
93
78
66
57
49
43
38
34
31
28
25
97
90
82
76
70
64
60
56
52
48
46
97
86
76
68
61
55
50
45
41
38
35
97
83
71
62
54
48
43
38
35
32
29
95
84
75
67
60
54
49
44
41
38
35
95
81
70
61
53
47
42
38
34
31
29
91
78
68
59
52
46
42
37
34
31
28
91
76
65
55
48
42
37
33
30
27
25
Zonal Lumens Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens %Lamp
3029
4999
8017
9292
0
9292
26.6
43.8
70.3
81.5
0
81.5
%Fixture
32.6
53.8
86.3
100.0
0
100.0
* With reverse apex lens
BALLAST
LER.FL
ENERGY COST ** DESCRIPTION
LUMENS
FACTOR
77
$3.12
(2) 32W T8
2850
.90
74
$3.24
(3) 32W T8
2850
.87
77
$3.12
(4) 32W T8
2850
.88
** Comparative yearly lighting energy cost per 1000 lumens
WATTS
57
85
107
Lithonia Lighting
Sheet #: SP8-2x4
© 1999 Acuity Brands Lighting, Inc., Rev. 3/12/09
Fluorescent
One Lithonia Way, Conyers, GA 30012
Phone: 800-858-7763 Fax: 770-929-8789
www.lithonia.com
Type: ________________________
Bruno
Indirect T8
S P E C I F I C AT I O N S
Project: ______________________
Pendant Mount — Modular / 8” X 2” Rectangular
BRM1
CATALOG NUMBER
__________ __________ __________ __________ __________ FT __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Examples:
BRM1 2 32 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 SCEP — BRM1 3 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21
AVAILABLE FIXTURES
■ BRM1 - 1
■ BRM1 - 2
■ BRM1 - 3
1 11⁄16”
1 11⁄16”
8 1⁄4”
1 11⁄16”
8 1⁄4”
8 1⁄4”
SPECIFICATIONS
Construction
Finish
Fixture Length
Housing is a nominal 8 1⁄4” x 1 11⁄16” rectangular
channel formed from cold-rolled steel. 5⁄8” thick
aluminum die cast end cap is standard, 4” sculpted
die cast aluminum end cap is optional.
Fine textured white polyester powder paint
is standard. Consult factory for special finish
requirements.
4’ 3⁄8”, 8’ and 12’ lengths in a single section for
nominal support spacing 4’-0” and 8’-0”. For total
fixture length, add 5⁄8” for each flat end cap and 4”
for each sculpted end cap. Using internal joiners, 4’
and 8’ sections can be joined to form longer rows.
Consult factory for availability of 12’ length fixture
section.
Electrical
Specify 120V, 277V, or 347V. Pre-wired with
16AWG fixture wire. For special circuiting or wire
gauge, consult factory. Plug-in electrical connectors
included. UL and C-UL listed and labeled.
Reflectors
Die formed specular reflector with 95% reflectance.
ORDERING LOGIC
Use guide below to order complete fixture runs from four feet to one-hundred feet in increments of four.
______________
______________
________________
______________
___________ FT
______________
______________
________________________
______________
Fixture
# of Lamps in
Cross Section
Lamp Type
Reflector
Ballast Type
SPR
Maximum
Section
Length
Voltage
32
Nominal
Row
Length1
120
277
347
GEB10
ADEZ4
ECO104
ADZT4
# of Emergency
Modules2
BRM1
1
2
3
______________
Emergency Type2,3
Specular
Reflector
R4
R8
R12
______________
________________
______________ / ______________
Switching
Lamp Color
Mounting Type
Blank No Emergency or SCT
Night Light
EL
Emergency
DCT
Battery Pack
EC
Emergency /
Night Light Circuit
EN
Emergency
Battery Pack
with Night Light
Circuit
Single
L/LP
Circuit
LP730
Dual Circuit LP735
LP741
LP830
LP835
LP841
No Lamp
3000K 70+ CRI
3500K 70+ CRI
4100K 70+ CRI
3000K 80+ CRI
3500K 80+ CRI
4100K 80+ CRI
Reference Lamp Chart on
website or consult factory for
other options.
F1
F1A
F2
F3
F4A
F4B
F4C
/
T-Bar Ceiling (Universal
Mounting Bracket)
T-Bar Ceiling (UMB with
Integrated J-Box)
Hard Ceiling (Horizontal
J-Box)
Stem Mount
IDS Clip 15⁄16” Tee
IDS Clip 9⁄16” Tee
IDS Clip Screw Slot
<10% THD ELECTRONIC
Advance Mark 10 dimming
Lutron ECO-10 dimming
Advance Mark 7 0-10v dimming
Blank
1SE
2SE
Reference Ballast Chart on website or consult XSE
factory for other options.
No Emergency
1 section
2 sections
X sections
______________
_________________________________
Overall Suspension
Finish
Options
12
15
18
21
24
XX
C210
ACG
APF
CP
DL
DU
ELH
ELS
GLR
GMF
NYC
SCEP
12” overall suspension
15” overall suspension
18” overall suspension
21” overall suspension
24” overall suspension
XX” overall suspension
Standard White
White (finetextured low
gloss)
C110 Painted to match
Aluminum Finish
C099 Custom Color
Adjustable Cable Grippers
Alternate Power Feed
Chicago Plenum
Damp Location Label
Dust Cover
EM Through wire w/ Separate Feed
EM Through Wire w/ Single Feed
Fusing (Fast blow)
Fusing (Slow Blow)
New York City Code
Sculptured End Cap
Notes:
1
2
3
4
Must be in 4’ increments.
Optional.
EL and EC are installed in last 4’ of fixture sections and are not available concurrently with
each other. Separate feed required for each EL or EC unless ELS/ELH is specified.
Not available in 347 volt.
PEERLESS LIGHTING • Box 2556, Berkeley, CA 94702-0556 • Tel: 510.845.2760 • Fax: 510.845.2776 • www.peerless-lighting.com
© 2008 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark, and “Peerless Bruno” is a trademark of Acuity Brands Lighting. Products in this brochure may be covered by one or more U.S. Patents and Patents
Pending. Peerless Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.
Bruno
Type: ________________________
Project: ______________________
Indirect T8
PHOTOMETRICS
1-LAMP T8 with SPECULAR reflector
Pendant Mount — Modular / 8” X 2” Rectangular
BRM1
2-LAMP T8 with SPECULAR reflector
3-LAMP T8 with SPECULAR reflector
PEERLESS LIGHTING • Box 2556, Berkeley, CA 94702-0556 • Tel: 510.845.2760 • Fax: 510.845.2776 • www.peerless-lighting.com
© 2008 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark, and “Peerless Bruno” is a trademark of Acuity Brands Lighting. Products in this brochure may be covered by one or more U.S. Patents and Patents
Pending. Peerless Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.