construction/finish • A quality low-profile troffer with specification features for NEMA “G” grid, NEMA “NFG” narrow face grid, NEMA “GR” grid regressed, NEMA “NFSG” narrow faced slot grid, or NEMA “F” flange ceiling types. • 3" nominal housing depth. • Smooth rolled edges on all four sides for easy handling. • Die-formed one piece housing includes stiffening embosses and provides increased rigidity. • Housing is multi-stage phosphate treated for maximum corrosion resistance and finish coat is high reflectance baked white enamel. • Lamp pin openings in housing ends for easier relamping when using straight lamps (can be relamped without using openings). • Integral baffling system to prevent light leaks. • Integral wire hanger holes for independent wire suspension. • Embosses with holes provided in housing end for screwing to T-bar if desired. • Factory installed access plate in housing top includes 7/8" hole with rolled edge and 7/8" K.O. • Some models utilizing multiple ballasts will be supplied with a top mounted ballast box, which will increase the height of the luminaire. • T-bar grid clips built into luminaire, no extra parts required. Designed for use with standard grid ceiling members, 1-1/2" maximum height. • Carton includes integral carrying handle for easy handling and tear tape for easy opening. 424-SR electrical • cULus listed for damp locations. • Self-contained fluorescent emergency power packs can be incorporated, listed for dry locations. Static Recessed enclosures TG8 Troffer • Full “C” channel door frames for improved lens support and reduced shipping damage. • Flat steel door frame features smooth rolled edges inside and outside. • Door frame uses T-hinges and can be hinged and latched from either side. • Opposable stainless steel spring loaded latches are standard for easy operation and consistent retention. • Door frame has true mitered corners. 2x2 2 Lamp T8 U1-5/8" or U6 3 Lamp T8 U1-5/8" 2, 3, or 4 Lamp T5, T5HO, or T8 Specifier’s Reference Project Type Model No. Comments Green Choice: 2TG8217R-01-UNV-1/2-EBHE-LPT835HL 2 T Width 8 Ceiling Type R No. of Lamps – Revision – Door Finish – Options BLANK – White 1/2 – One 2-lamp ballast 1/3 – One 3-lamp ballast B – Black Door 1/21 – 2-lamp & 1-lamp ballasts 1/4 – One 4-lamp ballast Lens 2/2 – Two 2-lamp ballasts 01 – Pattern 12 prismatic acrylic EB – Electronic ballast, <20% THD 12 – DB-12, .125" nominal EB10I – T8 electronic ballast, instant start, <10% THD 19 – DB-19, .156" nominal EB10R – Electronic ballast, program rapid start, <10% THD 21 – Pattern 12, .125" nominal EBHE – T8 electronic ballast, high efficiency, std. ballast factor 30 – 1/2"x1/2"x1/2" silver plastic EBLHE – T8 electronic ballast, high efficiency, low ballast factor louver EBHHE – T8 electronic ballast, high efficiency, high ballast factor 34 – 1-1/2"x1-1/2"x1" silver plastic E1 – DEB-1 emerg. ballast, T8, 350-450 lumens, 120/277V louver E1CAN – DEB-1 emerg. ballast, Canada market, T8, Family Lamp Type/Wattage Housing 52 – 3/4"x3/4"x1/2" silver plastic 350-450 lumens, 120/347V T – TG8 Troffer 8 – Housing designed 14 – 14WT5 (22") louver E7 – DEB-7 emerg. ballast, T8, 600-700 lumens around T8 lamps 17 – 17WT8 (24") E5 – DEB-5 emerg. ballast, US or Canada market, T8, 24HO – 24WT5HO (22") 1100-1400 lumens, 120/277V 31U1 – 31WT8 1-5/8" (24") E5CAN – DEB-5 emerg. ballast, Canada market, T8 (2 or 3 lamp only) 1100-1400 lumens, 120/347V 31U6 – 31WT8 6" (24") E5ST – DEB-5ST emerg. ballast w/self test, T8, (2 lamp only) 1100-1400 lumens E7LP – DEB-7LP emerg. ballast T8/T5/T5HO,430-700 lumens E6LP – DEB-6LP emerg. ballast, US or Canada market, T8/T5/ Voltage T5HO, 750-1325 lumens, 120/277V Door Frame F1 – Installed flex, 3/8" diameter, 18 gauge, 3 wire, 6' BLANK – Flat Steel 120 F2 – Installed flex, 3/8" diameter, 18 gauge, 4 wire, 6' 277 GLR# – Fusing, fast blow (# = number of ballasts) 347 UNV – Universal LPT735 – Installed T8 lamps, 70+ CRI, 3500K voltage, LPT835 – Installed lamps, 80+ CRI, 3500K LPT835HL – Installed T8 hi lumen lamps, 80+ CRI, 3500K 120-277 volt 1W – 1-way gasketing, between lens & door frame (not avail. w/RA door) 2W – 2-way gasketing, 1W + gasketing between Accessories door frame & housing FKTG822 – Flange conversion kit 2x2 3W – 3-way gasketing, 2W + gasketing for field nstallation FMA22 – 2'x2' “F” mounting frame for NEMA “F” mounting between housing & ceiling SI – Specular insert (reflector) 2 – 2' G – Grid F – Flange 424-SR 02/14 (not included) 2 3 4 R – Revised housing 423-SR dimensions 2x2 TG8 Troffer 2, 3, or 4 Lamp CF TT5 ceiling configuration 2 Lamp 31U1 2 3" (76mm) T G 24" O.C. (610mm) 2 Lamp 31U6 F = Flange (NEMA F) SIDE SIDE ➞ 24" (610 mm) Access plate location 7/8" dia. hole Grid clip Access plate 90 Open with screwdriver and bend to 90º and over 90° photometry TG8 2x2 2 Lamp 31U6 Catalog No. 2TG8231U6R-01-1/2-EB Test No. 27135 S/MH 1.3 Lamp Type FB31U6 Lumens/Lamp 2800 Ballast Factor 0.88 Input Watts 55 Comparative yearly lighting energy cost per 1000 lumens – $3.58 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. TG8 2x2 3 Lamp 31U1 Catalog No. 2TG8331U1R-01-1/3-EB Test No. 27150 S/MH 1.3 Lamp Type FB31U1 Lumens/Lamp 2800 Ballast Factor .88 Input Watts 78 Comparative yearly lighting energy cost per 1000 lumens – $3.43 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. R 25" (635 mm) (NEMA Type G) Lay-in acoustical ceilings using exposed grid suspension, with tees for luminaires on 24" x 48" spacing. 7/8" dia. K.O.s 90 31U1 3" Max. 1" Min. Luminaire end Grid tees (by others) 2 G = Grid (NEMA G) 3 Lamp 31U1 1-1/2" 8 Ceiling type (NEMA Type F) Flange for acoustical ceilings using concealed mechanical suspension. Swing-jack mounting brackets: adjustment 3" max. and 1" min. Refer to sheet 801-CL for output information. 7/8" dia. K.O. Efficiency – 74.7% LER – 67 Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 165516551655 164916481654 162616321645 158616071629 153215661604 145615151568 135814431515 123713431425 109912151309 954 10341148 787836942 622651739 477475558 346324399 267216279 208173204 149141145 767772 Efficiency – 73.4% AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Light Distribution Average Luminance egrees Lumens % Lamp % Luminaire D 0-30 130923.4 31.3 0-40 214338.3 51.2 0-60 354363.3 84.7 0-90 418274.7 100.0 AngleEnd 45°Cross 45 442147915320 55 355337194222 65 268325123093 75 263321902583 85 285728952707 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 898989 868686 8282 181 7875 807773 7370 275 6864 726863 6561 368 6056 675955 5754 463 5548 615447 5246 557 4842 564741 4641 654 4538 534438 4236 750 4034 484034 3933 846 3630 463630 3529 944 3428 423428 3328 1040 3226 403026 2925 LER – 70 Candlepower Cross 246424642464 244724572459 241424322441 235923862409 227223182364 215822342289 201221152196 184019632059 164517671894 142015341662 116912711375 914 10141088 678736823 498493583 383328401 306235278 230184200 120104106 TER – 60 TER – 62 Light Distribution Average Luminance egrees Lumens % Lamp % Luminaire D 0-30 193323.0 31.4 0-40 315337.5 51.2 0-60 522562.2 84.8 0-90 616373.4 100.0 AngleEnd 45°Cross 45 658071087701 55 522157926215 65 386138224520 75 387429753519 85 451139103985 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 868686 848484 8181 180 7773 787572 7169 273 6863 716761 6459 368 5955 665854 5653 461 5447 605346 5146 556 4741 564741 4640 653 4438 524236 4136 748 4034 473933 3833 846 3529 453529 3429 942 3428 413327 3227 1040 3025 393025 2925 Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled, “Contain Mercury” and/or the symbol “HG”. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org © 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 424-SR 02/14 page 2 of 2 Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008