10-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT R1 B1 Y1 B2 Y2 698–960 1695–2180 2490–2690 1695–2180 2490–2690 X X X X X 65° 65° 65° 65° 65° 2°–16° 2.5°–12° 2.5°–12° 2.5°–12° 2.5°–12° set by 10-Port Antenna 698–960/1695–2180/2490–2690/1695–2180/2490–2690 65°/65°/65°/65°/65° 15/17/17/17.5/18dBi 2°–16°/2.5°–12°/2.5°–12°/2.5°–12°/2.5°–12°T Type No. 80010874 Left side, lowband R1, connector 1– 2 698 – 960 Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Upper Side Lobe Suppression, 20° Sector above Main Beam Cross Polar Isolation Port to Port Isolation MHz dBi dBi 698 – 806 14.2 14.1 ± 0.5 791 – 862 14.6 14.5 ± 0.6 824 – 894 14.8 14.7 ± 0.6 880 – 960 15.0 14.8 ± 0.4 ° 67 ± 3.5 63 ± 3.8 62 ± 2.6 61 ± 1.7 dB > 22 > 23 > 24 > 27 dB > 22 > 23 > 23 > 21 dB > 7.5 > 7.0 > 7.0 > 7.0 dB < 1.5 < 1.5 < 1.5 < 2.5 ° 14.1 ± 1.2 12.9 ± 0.6 12.5 ± 0.7 11.7 ± 0.6 ° 2.0 – 16.0 ° < 0.6 < 0.6 < 0.6 < 0.5 dB > 12 > 14 > 13 > 14 dB > 14 > 14 > 13 > 14 dB dB > 28 > 28 (R1 // B2, Y2) > 30 (R1 // B1, Y1) 936.5152 ngmn 04.25.02.02 Subject to alteration. Max. Effective Power W 300 (at 50 °C ambient temperature) per Port Max. Effective Power W 600 (at 50 °C ambient temperature) Port 1–2 Values based on NGMN-P-BASTA (version 9.6) requirements. 80010874 Page 1 of 4 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 10-Port Antenna Left side, highbands Cross Polar Isolation Port to Port Isolation MHz dBi dBi 1695 – 1880 16.4 16.3 ± 0.6 1695 – 2180 1850 – 1990 16.9 16.8 ± 0.4 2490 – 2690 2490 – 2690 17.0 16.7 ± 0.5 ° 63 ± 5.9 59 ± 2.5 57 ± 3.6 61 ± 6.0 > 24 > 26 > 27 > 26 dB > 16 > 20 > 22 > 15 dB > 8.0 > 8.5 > 10.0 > 9.0 dB < 3.0 < 2.5 < 1.5 < 2.0 ° 6.8 ± 0.3 6.5 ± 0.3 6.2 ± 0.5 4.9 ± 0.3 ° 2.5 – 12.0 2.5 – 12.0 ° < 0.3 < 0.3 < 0.3 < 0.3 dB > 16 > 16 > 16 > 17 dB > 13 > 16 > 16 > 15 dB > 28 > 30 (B1 // R1, Y1, B2, Y2) > 30 (Y1 // R1, B1, B2, Y2) dB Right side, highbands Cross Polar Isolation Port to Port Isolation 1920 – 2180 17.1 17.0 ± 0.5 dB Max. Effective Power W per Port Max. Effective Power W Port 3–4 + Port 7–8 Values based on NGMN-P-BASTA (version 9.6) requirements. Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Upper Side Lobe Suppression, 20° Sector above Main Beam Y1, connector 7–8 7– 8 150 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature) B2, connector 5 – 6 Y2, connector 9–10 9– 10 MHz dBi dBi 1695 – 1880 16.9 16.9 ± 0.3 1695 – 2180 1850 – 1990 17.2 17.1 ± 0.3 ° 66 ± 2.9 66 ± 2.3 66 ± 2.7 62 ± 2.5 dB > 25 > 24 > 23 > 25 dB > 20 > 20 > 21 > 15 dB > 14.0 > 12.5 > 12.0 > 7.0 dB < 1.0 < 2.0 < 2.0 < 1.0 ° 6.9 ± 0.4 6.5 ± 0.4 6.2 ± 0.6 ° 1920 – 2180 17.4 17.3 ± 0.5 2490 – 2690 2490 – 2690 18.0 17.9 ± 0.3 2.5 – 12.0 5.0 ± 0.3 2.5 – 12.0 ° < 0.3 < 0.3 < 0.4 < 0.4 dB > 17 > 16 > 17 > 16 dB > 16 > 15 > 15 > 15 dB dB Max. Effective Power W per Port Max. Effective Power W Port 5–6 + Port 9–10 Values based on NGMN-P-BASTA (version 9.6) requirements. > 28 > 30 (B2 // R1, B1, Y1, Y2) > 30 (Y2 // R1, B1, B2, Y2) 150 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature) Page 2 of 4 80010874 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 936.5152 ngmn 04.25.02.02 Subject to alteration. Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Upper Side Lobe Suppression, 20° Sector above Main Beam B1, connector 3 ––4 4 10-Port Antenna Mechanical specifications Electrical specifications, all systems Impedance Ω 50 VSWR < 1.5 Return Loss dB > 14 Interband Isolation dB > 28 Passive Intermodulation dBc < –150 (2 x 43 dBm carrier) Polarization ° +45, –45 900 (at 50 °C ambient Max. Effective Power W temperature) for the Antenna Values based on NGMN-P-BASTA (version 9.6) requirements. Input Connector Position Adjustment Mechanism Wind load (at Rated Wind Speed: 150 km/h) Max. Wind Velocity N | lbf km/h mph Height / Width / Depth mm inches Category of Mounting Hardware Weight kg lb Packing Size mm inches Scope of Supply 10 x 4.3-10 female bottom FlexRET, continuously adjustable Frontal 690 | 155 Lateral 250 | 56 Rearside 1270 | 286 241 150 1499 / 378 / 164 59.0 / 14.9 / 6.5 XH (X-Heavy) 31.0 / 36.0 (clamps incl.) 68.3 / 79.3 (clamps incl.) 1681 / 402 / 248 66.2 / 15.8 / 9.8 Panel, FlexRET and 2 units of clamps for 55 – 115 mm | 2.2 – 4.5 inches diameter Accessories (order separately if required) 2 clamps 1 downtilt kit Site Sharing Adapter Site Sharing Adapter Gender Adapter Port Extender Weight Units per approx. kg | lb antenna Mast diameter: 110 – 220 | 4.3 – 8.7 Downtilt angle: 0° – 12° 3-way (see figure below) 6-way (see figure below) 9.4 | 20.7 10.6 | 23.4 0.7 | 1.5 1.4 | 3.1 Solely to be used in combination with 0.045 | 0.099 the FlexRET module 86010153V01 0.16 | 0.35 1 1 1 1 Accessories (included in the scope of supply) 85010096 86010153V01 2 clamps FlexRET Mast diameter: 55 – 115 | 2.2 – 4.5 5.0 | 11.0 1 1 1499 | 59.0 85010097 85010099 86010154 86010155 86010162 86010163 Remarks mm | inches 1318 | 51.9 Description 1556 | 19.2 Type No. Material: Reflector screen: Aluminum. Fiberglass housing: It covers totally the internal antenna components. The special design reduces the sealing areas to a minimum and guarantees the best weather protection. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The color of the radome is light grey. All nuts and bolts: Stainless steel or hot-dip galvanized steel. Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. Configuration example with Site Sharing Adapter 86010154 FlexRET FlexRET FlexRET Configuration example with Site Sharing Adapter 86010155 FlexRET Site Sharing Adapter 3-way 3) FlexRET 1) 22 | 0.9 2) 150 | 5.9 3) 11 | 0.4 Site Sharing Adapter 6-way AISG BTS1 FlexRET All dimensions in mm | inches AISG BTS2 1) 2) 936.5152 ngmn 04.25.02.02 Subject to alteration. For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. BTS3 BTS1 BTS2 BTS3 BTS4 BTS5 BTS6 For more information please refer to the respective data sheets. 80010874 Page 3 of 4 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 10-Port Antenna B1 L 4 B1 L 1695-2180 1695-2180 Y1 Y1 L 8 7 2490-2690 R R1 L R1 2 L 698 - 960 1 B2 R 5 1695-2180 1695-2180 Y2 Y2 R 698 - 960 6 10 2490-2690 R 9 2490-2690 97 | 3.8 2490-2690 L B2 3 141 | 5.5 164 | 6.5 * 229 | 9.0 * Layout of interface: 131 | 5.2 221 | 8.7 311 | 12.2 378 | 14.9 * Bottom view * Dimensions refer to radome All dimensions in mm | inches Frequency range Array Connector 698– 960 MHz 1695–2180 MHz 1695–2180 MHz 2490–2690 MHz 2490–2690 MHz R1 B1 B2 Y1 Y2 1–2 3–4 5–6 7–8 9 – 10 Page 4 of 4 80010874 Y1 Y2 B1 R1 Left B2 2x Right Any previous data sheet issues have now become invalid. www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 936.5152 ngmn 04.25.02.02 Subject to alteration. Correlation Table FlexRET A flexible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas. ● ● Compliant to AISG 1.1 and 3GPP/AISG 2.0 Single RETs or Multi RET displayed Protocols Logical interface ex factory 1) Operates as Ex factory Input voltage range V Power consumption W Connectors Hardware interfaces Housing material Weight Packing size (H x W x D) Dimensions (H x W x D) ● Daisy Chain feasibility Pre-configurated 86010153 Type No. Adjustment time (full range) Adjustment cycles Temperature range Protection class Lightning protection ● sec °C g lb mm inches mm inches compliant to AISG 1.1 and 3GPP/AISG 2.0 3GPP/AISG 2.0 Single RETs or Multi RET Single RETs 10 ... 30 (pin 1, pin 6) < 0.5 (stand by); < 10 (motor activated) 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: female RS 485A/B (pin 5, pin 3); power supply (pin 1, pin 6); DC return (pin 7); according to AISG / 3GPP 40 (typically, depending on antenna type) > 50,000 –40 … +60 IP 24 (installed) AISG interface (each pin) 2.5 kA (10/350 μs) 8 kA (8/20 μs) Profile: Aluminum anodized; cover: Aluminum die cast coated 350 0.77 245 x 93 x 102 9.6 x 3.6 x 4 142 x 71 x 50.4 5.6 x 2.8 x 2 1) The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 with a vendor specific command. Start-up operation of the FlexRET is only possible in a RET system supporting 3GPP/AISG 2.0! 1) Please note: If the Primary which controls the FlexRET system does not support the default ex-factory interface setting, then the RCU must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. 936.4643/b Subject to alteration. If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna after power on automatically. It is not necessary to configurate the FlexRET manually. Standards: EN 60950-1 (Safety) EN 60950-22 (Safety – Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1st edition Certification: CE, FCC Scope of supply: FlexRET Optional: Site Sharing Adapter (86010154 or 86010155) to create independent logial interfaces at one antenna or site. Makes it possible to operate with more than one independent Node B. Please note: In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1). The respective information can be found on the site documentation which is included in the scope of supply. 86010153 Page 1 of 4 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 FlexRET Startup of FlexRET The FlexRET module included in the antenna is preconfigured with the following information: Antenna model no., Antenna Serial no., Antenna configuration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will find the FlexRET. You only need to insert your additional data. Connecting the control cables: Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for fixing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or by a special torque screw driver (order no. 85010080). See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only. Please note: If the daisy chain output is not used, do not remove the protection cap. 936.4643/b Subject to alteration. For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU. Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device. Page 2 of 4 86010153 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 FCC – Statements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ubject to alteration. &++. 936.4643/b %'(#)%%'!()$#$'"*-=#*()'#%%!!(*-%%'!('$ -"%)(!#4=-%!$))$#()*)$'(*-*-$#)$#((*+#)(39A:!=%%'!# $)%(%'$*''$*!!2)9B:!=*)!()*'!=%%'!$)%)')$*)'$*!! '$!)'&*(*2""(!'$*!!()(*(%)!=#$"%'$"))'!$#)$##"#)4 (!(()!%%')*($"%!(,)##7@@C4 )%%'!#*"'&*!!((()$#$'"!#$'"7@@C*#4 *,/%-,(!!!) ;#.<#($'"$)$#(#$)-%'((!.%%'$+.)%').'(%$#(!$'$"%!#$*! +$)*('5(*)$').)$$%'))&*%"#)4 86010153 Page 3 of 4 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 FCC – Statements Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: Kathrein Inc., Scala Division Address: PO Box 4580, Medford Oregon . 97501 Telephone: (+01)541 779 6500 Type of Equipment: 936.4643/b Subject to alteration. Model Name: FlexRET FCC ID SP3-86010153 Page 4 of 4 86010153 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820 Mounting Hardware Clamp (Wind Load Category “XH”) Clamp 85010096 Type No. Suitable for mast diameter Scope of supply mm inches Material – Clamp – Screws – Nuts Weight 55 – 115 2.2 – 4.5 1 x lower clamp 1 x upper clamp Hot-dip galvanized steel Hot-dip galvanized steel Stainless steel 5.0 11.0 kg lb F Torque MA = 40 Nm Torque H upper clamp MA = 40 Nm D Torque MA = 40 Nm A H B C lower clamp upper clamp Torque MA = 40 Nm G lower clamp G E 1) Attention! 936.5063 Subject to alteration. Square of the screw must be positioned in the square hole before tightening the nut. 2) All nuts have the same wrench size 17. mm inches A B C D E F G H 200 7.9 69 2.7 89 3.5 55 – 115 2.2 – 4.5 150 5.9 130 5.1 (19) (0.7) (39) (1.5) Please note: Kathrein does not recommend to use counter nuts. 85010096 Page 1 of 1 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820