B U L L E T I N Static Transfer Switch Power Panel 6415 Standard Features Continuous monitoring of sources Automatic transfer operation Manual transfer capability Automatic retransfer Remote control and monitoring Additional RS-485 port Digitally adjustable parameters Redundant logic power CE marking Applications Communication/Data Centers Hospitals Airports and military bases Industrial plants Commercial buildings Options Site testing and maintenance Installation and start-up Spare parts Training programs This Static Transfer Switch Power Panel (STS-PP) automatically transfers critical loads from a primary power source to an alternate power source in the event of interruption or abnormal conditions. Designed using siliconcontrolled rectifier (SCR) power-switching elements, the STS-PP transfers the critical load between power sources in less than 1/4 cycle upon loss of source – more than 10 times shorter than traditional electromechanical switches – appearing seamless to even the most sophisticated loads. Accomplishing rapid transfer without cross-connecting power sources, the STS-PP ensures that no damage can occur to either power source. This also allows for transfer between two dissimilar power sources – a feature far superior to mechanical open-or closed-transition automatic transfer switches. The STS-PP has precision digital sense and control circuits that do not require calibration or adjustments (no potentiometers). The sensed analog signals are converted to digital format before being interpreted. All operational parameters are set digitally. The STS-PP has dedicated logic for the critical interpretation and switching operations. This dedicated logic ensures fast and predictable operation at all times. A microcontroller performs the system level functions such as operator interface (control panel), operating parameter setup, and remote monitoring and control. The STS-PP is designed to mount in a switchgear panel or power distribution unit that has the necessary circuit breakers for bypass and isolation. STS-PP Bulletin 6415 Electrical Characteristics: Voltage/Frequency ..... 120 to 400 VAC, 3-phase 50 or 60Hz (selectable) 3 or 4-pole Current Rating ............ 100A, 150A, 200A, 250A, 400A , 600A, 800A Efficiency .................... 99% nominal Environmental Specifications: Temperature ............... 0°C to 40°C Humidity ..................... 95%, noncondensing Panel Indicators: ............. Summary Alarm Source 1 active Sense Time ............ <2ms upon loss of source Source 2 active Sense/Transfer ....... 1/4 cycle upon loss of source Source 1 preferred RS-485 Port ............ Remote status & operation Source 2 preferred Auto retransfer on/off User Adjustable Settings: Overvoltage Load power on Undervoltage Breaker status Retransfer delay time Panel Controls: ............... Fault reset Phase angle error Lamp test Transfer delay (optional) Auto retransfer on Transfer Inhibit (optional) Auto retransfer off Select source 1 Select source 2 Control enable Operational Characteristics: Physical Characteristics: Rating Dimensions (mm) HxWxD 100A, 3-pole 150A, 3-pole 200A, 3-pole 250A, 3-pole 400A, 3-pole 600A, 3-pole 800A, 3-pole 800 x 555 x420 800 x 555 x420 800 x 555 x420 800 x 555 x420 1200 x 820 x520 1200 x 920 x520 1200 x 920 x520 Weight (kg) 91 91 91 91 135 220 220 Rating Dimensions (mm) HxWxD 100A, 4-pole 150A, 4-pole 200A, 4-pole 250A, 4-pole 400A, 4-pole 600A, 4-pole 800A, 4-pole 800 x 555 x420 800 x 555 x420 800 x 555 x420 800 x 555 x420 1200 x 820 x520 1200 x 920 x520 1200 x 920 x520 Weight (kg) 95 95 95 95 143 245 245 Specification subject to change without notice EUROATLAS GmbH Zum Panrepel 2 28307 Bremen Germany Phone +49-421-486930 Fax +49-421-4869341 info@euroatlas.de www.euroatlas.de