MDRCs Load ABB Other modular devices Load management devices Contents Selection tables E 450 priority switches .............................................................................................. TWS twilight switches ............................................................................................... STL light level switches............................................................................................. RAL overload alarms ................................................................................................. E 228 WM alarm indicator ........................................................................................ LSS1/2 load shedding switches ............................................................................... SQZ3 phase and sequence relays ............................................................................ LEE 230 power failure signalling extractable lamp ................................................... Max./min. current/voltage ammetric and voltmetric relays ...................................... E 235 mains disconnection relays ............................................................................ E 236 undervoltage monitoring relays ...................................................................... 1/128 1/129 1/131 1/132 1/134 1/135 1/136 1/137 1/138 1/139 1/140 1/127 1SDC007200C0201 0101_ModularDINrail.indb 127 7-02-2005 17:41:29 System Selection tables pro M compact® Load management devices E 450 priority switches E 450 E 450 priority switches The priority switch is used in wiring systems where existing lead cross sections or the size of the power supply service box do not allow for simultaneous operation of two powerful loads (e.g. storage heating and flow-type heater). The priority switch disconnects the long-term load (storage heating) for as long as the short-term consumer (flow-type heater) is switched on. The coil of the priority switch is connected in series to the short-term load. When this load is switched on, the NC contact of the priority switch disconnects e.g. the heating system contactor. SK 0114 B 99 Rated current range Power loss Order details W Type code Bbn Price 4016779 1 piece Order code Price group Weight 1 piece Pack unit EAN kg pc. 41590 3 0.1 10 20950 2 0.1 10 For pneumatically controlled flow-type heaters 6,7 ... 39 A 2.4 E 451- 5.7 A 2CDE160000R0901 For electronically controlled flow-type heaters 2.4 E 452-5,7 A 2CDE160010R0901 SK 0078 Z 00 6.7 ... 39 A Technical features Operating coil Range of rated current equivalent to Threshold current OFF delay (max.) Max. continuous current Therm. continuous capacity at 40 °C/104 °F Contact assembly Control contact Rated contact current at 250 V Contact material Max. switching voltage Max. switching capacity Max. switched current Max. inrush current peak Electr. service life Mechanical service life Max. electrical switching rate ON duration Ambient temperature Response time Release time Test voltage contact/coil Clearance and creepage distance Degree of protection Protection against electric shock Terminal contact 1/128 E 451-5.7 E 452-5.7 6.7 … 39 A 1.5 … 9 kW at 230 V, 4.6 … 27 kW at 230/400 V 3.1 … 5.3 A 0 main half waves 2 main half waves 43 A 5W 1 NC contact 1A solid silver 400 V 230 VA 1A 5A > 105 operations ca. 2 x 106 operations ca. 1800 operations/hour 100 % – 20 °C/– 4 °F to + 40 °C/104 °F 10 … 20 ms 5 … 20 ms M 20 ms 2.5 kV C/250 V AC cording to IEC 669-1-23 IP 40 according to DIN VDE 0106 Part 100 (BGV A2) series coil up to 16 mm2, control contact up to 2.5 mm2 ABB 1SDC007200C0201 0101_ModularDINrail.indb 128 7-02-2005 17:41:31 System Selection tables pro M compact® Load management devices TWS twilight switches They switch-on and/or switch-off operating illuminating devices at preset level of ambient lighting. Used in combination with sensor detecting if lighting level is higher or lower than preset threshold. Versions with built-in time switch allow the control of the lighting plant in relation to the level of ambient lighting combined with a specific time program. MDRCs Load TWS TWS twilight switches with sensor LS-1 Channels Order details Bbn Price 8012542 1 piece TEPM0244 Type code Order code Price group EAN Weight 1 piece Pack unit kg pc. 1 TWS-1 2CSM111200R1341 335009 0.250 1 2 TWS-2 2CSM112200R1341 507109 0.350 1 1 DTS7/1-TWS* 2CSM121300R1351 507208 0.350 1 2 DTS7/2-TWS* 2CSM122300R1351 507307 0.350 1 Weight 1 piece Pack unit * With built-in weekly program time switch Sensor (as spare part) Order details Bbn Price 8012542 1 piece Price group Type code Order code EAN kg pc. LS-1 2CSM000010R1341 335108 0.050 1 SENSOR 7 1 2 NA 230V~ 3 C 4 NC 5 LOAD OEPM0050 6 Technical features Rated voltage Contact capacity [V] [A] [W] ABB Contact type Frequency Channels (contacts) number [Hz] [Ch] ON/OFF memories [n°] Time delay [s] Adjustment range Accuracy class Protection degree Adjustment Operating temperature [Lux] [s] [IP] Power consumption Modules Standards [W] [n°] [°C] a.c. 230 16 (ohmic load) 2.5 (inductive load) 1000 (fluorescent lamps) free-switching contact 50/60 1 (DTS7/1+TWS) 2 (DTS7/2+TWS) 20 (DTS7/1+TWS) 30 (DTS7/2+TWS) 0…100 ON 0…100 OFF 2…500 ± 2.5/day 20 (twilight), 65 (sensor) electronic -25…+55 (twilight) -30…+70 (sensor) 5 3 EN 60730-1, IEC 730-1, CEI 107-70, VDE 0633 1/129 1SDC007200C0201 0101_ModularDINrail.indb 129 7-02-2005 17:41:32 System Selection tables pro M compact® Load management devices TWS twilight switches TWS DTS + TWS operating principle 3 3 4 DTS + TWS LED ON 4 5 0...100 sec. LED OFF DTS + TWS 6 5 0...100 sec. 7 6 7 8 8 3 4 LED OFF ˜ 1,3 OEPM0050 5 3 4 5 LED ON t TWS1 M ~ 1 2 3 4 5 user network 10 11 sensor TWS2 M ~ 1 2 3 4 5 6 user (ch 1) network 7 8 9 user (ch 2) 10 11 sensor DTS7/1-TWS, DTS7/2-TWS M ~ 1 2 network 1/130 3 4 user (ch 1) 5 6 7 user (ch 2) 8 9 10 11 sensor ABB 1SDC007200C0201 0101_ModularDINrail.indb 130 7-02-2005 17:41:34 System Selection tables pro M compact® Load management devices STL light level switches STL light level switches SK 0085 B 97 Light level switch STL 101 switches the connected lighting circuit (STL 103 up to 3 lighting circuits) on or off, depending on the brightness measured. Extra low-voltage signals of a photo sensor installed outside a building or in the immediate proximity of a window are processed according to the preset reference values. Number of lighting group Order details Bbn Price 4016779 1 piece Price group Weight 1 piece Pack unit Type code Order code EAN kg pc. 1 STL-101 GJV5010000R0011 604401* 0.400 1 3 STL-103 GJV5010000R0012 127004 0.450 1 Weight 1 piece Pack unit MDRCs Load STL * Bbn No. 40122233 SK 074 B 00 Order details Bbn Price 4016779 1 piece Price group Type code Order code EAN kg pc. STL LF-103 GJV0211370R0171 127004 0.100 1 2CDC 052 227 F0203 SK 073 B 00 Photo sensor (IP 54) and mounting bracket STL-101 Technical features Rated voltage Power consumption Fusing Ambient temperature Photo sensor input Pushbutton input Control voltage range Contact load Switching values Delay time Class and degree of protection Terminals Max. cable length Pollution degree Terminal assignment CE requirements Power loss ABB 230 V a.c. 50 HZ; d.c not permissible (will destroy equipment) ca. 2 W (a.c. 3 W for STL-103) external 6 A/ for each load circuit 0 °C/32 °F to 45 °C/113 °F, supply air if installed horizontally one photo sensor 1 pushbutton (NO contact), STL-101: 11/13; STL-103: 4/6 0 - 5 V d.c. photo sensor, pushbutton, basic insulation according to IEC 664 (10/92) no safety extra-low voltage max. 10A/250 V~ or 10A/30 V- (µ) adjustale between ca. 10 -1000 Lux or 200 to 20000 Lux adjustable in the range of 5 seconds to 20 minutes II (total insulation), IP 20 0.5 mm2 - 2.5 mm2 for one-wire conductor or with connector sleeve 100 m, control leads 0.5 mm2, load and supply lines 1.5 mm2 2 (dry, non-conductive, according to IEC 664, 10/92) see connection example, incorrect installation may lead to malfunctioning or destruction EMC fulfilled acc. to EN 61547 (04/96), low voltage acc. to IEC 669-2-1 (11/94) 6 for STL-101; 8 for STL-103 1/131 1SDC007200C0201 0101_ModularDINrail.indb 131 7-02-2005 17:41:34 System Selection tables pro M compact® Load management devices RAL overload alarms RAL RAL overload alarms TEPM0245 Main circuit-breaker downstream installed, they constantly compare preset power consumption value to effective system power consumption, which is related to the number of devices operating simultaneously. An acoustic alarm alerts that it is necessary to switch-off some appliances in order to avoid the tripping of the main circuit-breaker. The device calibration is 3 kW. Adjustable range Order details kW Type code Bbn Price 8012542 1 piece Order code EAN Price group Weight 1 piece Pack unit kg pc. 0/3 RAL 3 2CSM111200R1301 400509 0.200 1 0/6 RAL 6 2CSM121200R1301 400608 0.200 1 Technical features Rated voltage Un Rated current In Rated contact capacity In Rated frequency Adjustment ranges Power consumption Modules [V] [A] [A] [Hz] [A] [W] [n°] a.c. 230 18.3 (for 3 kW); 27.5 (for 6 kW) 12 cosϕ=1; 4 cosϕ=0.8 50 0 ...18.3/0…27.5 10 2 Additional technical features RAL overload alarms are equipped with an acoustic alarm which signals an exceeding power consumption, allowing the user to disinsert loads before the energy-limiting circuit-breaker trips. An appropriate relay output contact allows the choice between the following functions: a) remote signalling (acoustic or lighting) b) opening a specific divisional circuit-breaker and then disabling a particular not primary electric appliance. If appropriately used, the function b) causes the automatic switchoff of one or more appliances in order to keep the power consumption within the preset limits, avoiding the unexpected tripping of current-limiting device installed outside the housing (i.e. in the basement). Reset manually. 1/132 ABB 1SDC007200C0201 0101_ModularDINrail.indb 132 7-02-2005 17:41:37 System Selection tables pro M compact® Load management devices RAL overload alarms MDRCs Load RAL Acoustic alarm N U 3kW for RAL 3, 6kW for RAL 6 MAX 230 V~ L 5 6 7 OEPM0051 Overload RAL alarm cannot be connected to a contactor. 8 Load release L 230 V a.c. N Main circuit breaker 6 8 Undervoltage release (230 V a.c.) in case of circuit-breaker tripping RAL 1 2 3 Lights ABB Dedicated socket OEPM0052 5 1/133 1SDC007200C0201 0101_ModularDINrail.indb 133 7-02-2005 17:41:38 System Selection tables pro M compact® Load management devices E 228 WM alarm indicator E 228 WM E 228 WM alarm indicator It can report an alarm signalling switched on by the closing of any kind of external contact (fault, warning device, etc.) through an acoustic and lighting alarm. TEPM0251 Order details Bbn Price 4012223 1 piece Price group Weight 1 piece Pack unit Type code Order code EAN kg pc. E 228-WM 2CDE100021R1401 630301 0.070 1 Wiring diagram L Operation N 1 External contact NO (monitored) has changed the initial position: - LED 3 switches on (blinking) - Acoustic alarm on 1 2b T 2a and 2b Acoustic alarm disabled on the product (2a) or remotely (2b): - LED 3 light is fixed up to system reset 3 2a 3 Alarm indicator LED OEPM0058 N Technical features Rated voltage Un Rated frequency Power consumption Modules Cycle time Sound level Ambient temperature 1/134 [V] [Hz] [W] 230 AC 50 <4 1 on/off 1 sec ±10% 60 dB -20 °C up to +50 °C ABB 1SDC007200C0201 0101_ModularDINrail.indb 134 7-02-2005 17:41:38 System Selection tables pro M compact® Load management devices LSS1/2 load shedding switches LSS1/2 load shedding switches Main circuit-breaker downstream installed, they compare the higher allowed and preset value of power consumption to the effective system power consumption avoiding the tripping of the main circuit-breaker through switching-off in sequence of maximum two not primary loads (NPL1 and NPL2) when the preset threshold is exceeded. A green LED signals the voltage and two red leds indicate load OFF. At preset time intervals the device automatically tries to insert again not primary disabled loads. Price group Weight 1 piece Pack unit Type code Order code EAN kg pc. LSS1/2 2CSM112500R1311 274407 0.400 1 Possible forced NPL 1 and NPL 2 switch-off Possible remote signalling 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 LOAD - The device must be main circuit breaker downstream inserted into the network - PL = Primary Load - NPL = Not Primary Load OEPM0150 L 230V~ NPL2 N NPL1 Single-phase wiring diagram Bbn Price 8012542 1 piece PL TEPM0246 Order details MDRCs Load LSS1/2 Technical features Rated voltage Un Rated capacity In Rated contact capacity In NPL1 and NPL2 Rated frequency Regulating thresholds [V] [A] [A] [Hz] [A] Load reinsertion delay Load disinsertion delay Indicators Load OFF remote signalling [A] Terminals Primary load Not primary loads Power consumption [W] Modules [n°] ABB a.c. 230 90 16 each (terminals 12 and 14) 50/60 5...30 10...60 15...90 5-7 min. (NPL1); 4-5, 50 min. (NPL2) about 2 sec. 1 green LED= supply voltage available 2 red LED= switched off loads 1 (terminals 11 and 13) 35 mm2 10 mm2 5 5 1/135 1SDC007200C0201 0101_ModularDINrail.indb 135 7-02-2005 17:41:39 System Selection tables pro M compact® Load management devices SQZ3 phase and sequence relays SQZ3 SQZ3 phase and sequence relays SQZ3 relay performs the following continue monitoring functions on three-phase networks at 400 V a.c.: - phase sequence - phase failure - minimum voltage (adjustable up to 70% of Vn). If one of the three failures is detected, the output relay (safety switching contact) intervenes with a delay adjustable from 2 to 20 seconds for minimum voltage only and controls the following: - acoustic alarms - motor controlling contactors - circuit-breakers with coils. TEPM0255 Order details Bbn Price 8012542 1 piece Price group Weight 1 piece Pack unit Type code Order code EAN kg pc. SQZ3 2CSM111310R1331 372004 0.300 1 Wiring diagram L1 L2 L3 Automatic circuit breaker L1 L2 L3 7 8 9 10 11 12 SQZ3 400V 50-60Hz 70% OK Phases Sequence 400V 50Hz OK Three phases OK Min Voltage 100% Min Voltage 2 2 3 NO Output contact 4 NC 5 6 C Three-phase motor 10 A 250 V OEPM0055 1 20 Delay (s) Technical features Supply voltage Frequency Contact capacity Contact type Minimum voltage regulating trimmer Intervention delayregulating trimmer Insulation rating Protection degree Operating temperature Power consumption Modules 1/136 [Vn] [Hz] [A] [%] [s] [IP] [°C] [W] [n°] 400 V a.c. 50/60 10 (cosϕ=1) safety switching, changeover from 100 to 70 of Vn from 2 to 20 (only for min. voltage) II 20 -10…+55 10 3 ABB 1SDC007200C0201 0101_ModularDINrail.indb 136 7-02-2005 17:41:40 System Selection tables pro M compact® Load management devices LEE 230 power failure signalling lamp LEE 230 power failure signalling exctractable lamp The LEE 230 lamp is an automatic electronic lamp to be installed in any modular socket or wiring accessories socket with German standard VDE Schuko (M1173 or E1175) and Italian standard P11, 10 A or dual standard 10/16 A. MDRCs Load LEE 230 The device can operate as a power failure signalling lamp as well as a lighting device, to be used for example during maintenance activities or for looking for possible faults in the panel. Order details Bbn Price 8012542 1 piece Price group Weight 1 piece Pack unit Type code Order code EAN kg pc. LEE-230 2CSM110000R1361 844105 0.100 1 Technical features 2P 10 A plug Supply Recharge time Endurance Lighting level Operating temperature Min. life cycle [V] [h] [h] [mcd] [°C] distance between pins 19 mm, pin ø 4 mm 230 a.c., 50-60 Hz 24 3 3000 0…+45 5 years (battery) Additional technical features The LEE-230 lamp automatically switches on when the voltage fails; the built-in rechargeable battery guarantees the supply. It is particularly useful thanks to its construction and functional characteristics: – it can be extracted from the socket and used as a torch with ON-OFF button on its frontal side – when necessary it can work with standard sockets – it can be moved when it is needed – it has a long operation endurance, up to three hours – it is ready to use, it does not require installation – with a screw (ø 3.5 mm, L 16 mm) it is possible to fix it preventing the extraction from the M1173 ABB sockets with central hole – the projecting part of the Schuko profile is very small (8 mm). The two LEDs placed on the frontal side of the lamp indicate its operation condition: – the red LED indicates the recharge activity and that, in the case of a network voltage back-out, the lamp will remain off – the green LED indicates the recharge activity and that, in the case of a network voltage black-out, the lamp will switch on (it will automatically switch off when the voltage returns). By pushing the frontal pushbutton it is possible to change the status; if you do not use the lamp for a prolonged time it is suggested to set the first condition in order to preserve the battery life. ABB 1/137 1SDC007200C0201 0101_ModularDINrail.indb 137 7-02-2005 17:41:41 System Selection tables pro M compact® Load management devices Max./min. current/voltage relays RH/RL Max./min. current/voltage ammetric and voltmetric relays These devices are used to measure current (ammetric) and voltage (voltmetric) on single-phase electric networks for a perfect protection of devices used. The range includes: • maximum current (RHI) and maximum voltage (RHV) relay. The control relay remains on as long as the quantity to be measured is lower than the set threshold value; • minimum current (RLI) and minimum voltage (RLV) relay. The control relay remains on as long as the quantity to be measured is higher than the set threshold value. In both cases the relay switches off with a delay adjustable by the potentiometer, which also allows to adjust hysteresis (from 1 to 45%). Type Order details Bbn Price 8012542 1 piece TEPM0252 Type code Price group Weight 1 piece Pack unit Order code EAN kg pc. maximum current ammetric relay RHI 2CSM121310R1321 334309 0.300 1 maximum voltage voltmetric relay RHV 2CSM111310R1321 334101 0.300 1 minimum current ammetric relay RLI 2CSM122310R1321 334200 0.300 1 minimum voltage voltmetric relay RLV 2CSM112310R1321 334002 0.300 1 Technical features Rated voltage Un Switching contact capacity Rated frequency Ammetric relay alarm thresholds Voltmetric relay alarm thresholds Adj. calibration of In and Vn% Adjustable hysteresis value Time delay Power consumption Modules [V] [A] [Hz] [A] [V] [%] [%] [s] [W] [n°] a.c. 230 16 50/60 2, 5, 10 100, 300, 500 30...100 1...45 1...30 2 3 Additional technical features Control relay intervention lighting indication Power supply lighting indication Intervention lighting indication 2A C 5A 100V 300V 500V 10A 7 8 9 1 2 3 10 11 12 7 8 9 1 2 3 1/138 5 C NC NO 6 Output OEPM0060 N Supply 230 V~ L 4 OEPM0061 OEPM0059 C NC NO 10 11 12 N Supply 230 V~ L 4 5 6 Output OEPM0062 C red LED on=intervening green LED on=ON blinking green LED=intervening ABB 1SDC007200C0201 0101_ModularDINrail.indb 138 7-02-2005 17:41:43 System Selection tables pro M compact® Load management devices E 235 mains disconnection relays SK 0171 B 02 E 235 mains disconnection relays Constant exposure of electrical interference fields originating from live conductors - as is the case e.g. in bedrooms - may impair the well-being of people, experts say. With the extra base load adapter E235-GLA, the mains disconnection relays can be switched on manually. For the permanent installation of loads that switch on independently of the supply voltage, such as fluorescent lamps, a E235-GLE PTC base load element is available. Description Order details Bbn Price 4016779 1 piece SK 0172 B 02 Type code Order code Price group Weight 1 piece Pack unit EAN kg pc. mains disconnection relay E 235-NFS 2CDE110000R1701 571821 0.065 1 base load element E 235-GLE 2CDE100500R1711 571814 0.001 1 base load adapter E 235-GLA 2CDE100510R1711 571869 0.070 1 MDRCs Load E 235 2CDC 052 106 F0003 2CDC 052 107 F0003 Wiring diagram use with dimmer (potential-free NO contact) Technical features Short circuit rupturing capacity Rated frequency Range of control voltage Load of filament lamps Fluorescent lamp load: twin lamp circuit shunt compensated electronic ballast Induce load Max. switching capacity (cosϕ 0.5) Intrinsic consumption ca. 1 W Control voltage Adjustable making capacity Breaking capacity ON delay OFF delay Contact assembly Service life at rated load Ambient temperature Connection capacity (clamping terminal) ABB 16 A/230 V a.c. 50/60 Hz 0.9 to 1.1 Un 2300 W 100 W 56 W max. 36 W, dependent on manufacturer 6 A cosϕ = 0.6 3500 VA 5 V a.c. 2 - 15 VA 0.66 x making capacity 50 ms ca. 3 sec. 1 NO contact > 100000 switching cycles - 10 °C/14 °F to +45 °C/113 °F max 2.5 mm2 1/139 1SDC007200C0201 0101_ModularDINrail.indb 139 7-02-2005 17:41:44 System Selection tables pro M compact® Load management devices E 236 undervoltage monitoring relays E 236 E 236 undervoltage monitoring relays Function The green LED is lit when the supply voltage is applied. If each phase voltage exceeds 195 V (US1) or exceeds the preset threshold value (US2) with respect to the neutral including the hysteresis when switching the device on, the relay switches immediately into the working position. The yellow LED is lit. If at least one phase voltage falls below the threshold value, the relay goes back into its normal position and the yellow LED goes out. If also phase 2 fails, the green LED goes out, too. It is indispensable to connect the neutral conductor! Application For the control of three-phase undervoltage (each phase to neutral) of switchgear, also for installations according to DIN VDE 0107 (power installations in hospitals and rooms used for medical purposes outside of hospitals) and DIN VDE 0108 (power installations and safety supply in buildings where many people gather). US 1: 3 phases to neutral with fixed threshold at 195V; hysteresis fixed 5 % US 2: 3 phases to neutral with fixed threshold at 160 – 240V; hysteresis fixed 5 % Technical features Rated voltage Frequency Measuring range: supply voltage overload capacity Switching capacity Rated insulation voltage Rated surge voltage Tripping delay Clearence and creepage distance Mechanical service life Electrical service life at 10000VA Max. switching rate Ambient temperature Overvoltage category Accuracy in non-changing environment: setting tolerance (US 2) repeat accuracy temperature effect Terminals Specifications EMC tests Displays Power loss 1/140 250 V a.c. 48-63 Hz 3N 400/230 V a.c. (terminals N-L1-L2-L3) 3N 459/265 V a.c. device in series (distance < 5 mm): 750 VA (3 A/250 V a.c.); device not in series (distance > 5 mm): 1250 VA (5 A/250 V a.c.) 250 V a.c. (corresponds with IEC 664-1) 4 kV ca. 100 ms > 6 mm (between contact and electronics) 20 x 106 operations 2 x 105 operations max. 6/min (1000 VA Ohmic load); max. 60/min (100 VA Ohmic load) -25 °C/-13 °F to +55 °C/131 °F III ≤5 % ±1 % ≤0.1 %/°C up to 4 mm2 VDE 0110 and VDE 0435 EM 50081-1 and EN 50082-2 LED green= supply voltage applied; LED yellow= relay status 1.7 W ABB 1SDC007200C0201 0101_ModularDINrail.indb 140 7-02-2005 17:41:46 System Selection tables pro M compact® Load management devices E 236 undervoltage monitoring relays Order details Bbn Price 4016779 1 piece Type code Price group Weight 1 piece Pack unit Order code EAN kg pc. E 236-US 1 2CDE165000R2001 511087 0.095 5 E 236-US 2 2CDE165010R2001 511094 0.095 5 SK 0130 B 00 SK 0129 B 00 2CO 2CO MDRCs Load Contact E 236 SK 0149 Z 00 SK 0148 Z 00 E 236 US 1 E 236 US 2 ABB 1/141 1SDC007200C0201 0101_ModularDINrail.indb 141 7-02-2005 17:41:47