CHILLER REPLACEMENT CONTRACTORS GUIDE YCAL – 15 to 65 TONS AIR COOLED SCROLL CHILLER YLAA – 70 to 175 TONS AIR COOLED SCROLL CHILLER YVAA – 150 to 500 TONS AIR COOLED SCREW CHILLER YCWL – 50 to 200 TONS WATER COOLED SCROLL CHILLER AIR-COOLED YCAL 15 TO 40 Pages 12-23 YCAL 41 TO 65 Pages 24-29 CHILLER REPLACEMENT CONTRACTORS GUIDE YLAA 70 TO 90 Pages 36-43 YLAA 91 TO 130 YCAL – 15 to 65 TONS AIR COOLED SCROLL CHILLER YLAA – 70 to 175 TONS AIR COOLED SCROLL CHILLER Pages 44-53 YLAA 131 TO 175 Pages 54-63 YVAA 150 TO 200 Pages 68-73 YVAA 201 TO 500 Pages 74-85 YVAA – 150 to 500 TONS AIR COOLED SCREW CHILLER YCWL – 50 to 200 TONS WATER COOLED SCROLL CHILLER WATER COOLED YCWL 50 TO 90 Pages 92-109 YCWL 91 TO 130 Pages 110-117 YCWL 131 TO 200 Pages 118-125 In-stock Chillers Ready for Quick Shipment When You Need Cooling Fast! Complete packages for quick ‘Plug & Play’ installation Unit Benefits Air-cooled Scroll Chillers Air-cooled Screw Chillers Air-cooled chillers using scroll-compressor technology ranging from 15 to 175 tons. Standard feature include: Air-cooled chillers using YORK® VSD Screw technology ranging from 150 to 500 tons. Standard features include: • Voltages: 200V, 230V, 380V, 460V, 380-415V/50Hz, 575V • Chilled-water supply range: 40 - 55°F; brine supply to 10°F • Ambient operation between 0 - 115°F • Single-point power connection reduces wiring costs • Non-fused disconnect switch simplifies installation and servicing • Control transformer eliminates separate control wiring • Micro-computer control panel is very user-friendly • Low-noise fans reduce radiated sound • Victaulic-grooved water connections reduce installation costs • Complies with ASHRAE Standard 90.1 on energy efficiency • Options are available upon request • Voltages: 200V, 230V, 380V, 400V, 460V, 380-415V/50Hz, 575V • Chilled-water supply range: 40 - 55°F; brine supply to 15°F • Ambient operation between 0 - 125°F • Single-point power connection reduces wiring costs • Non-fused disconnect switch simplifies installation and servicing • Control transformer eliminates separate control wiring • VSD increases reliability at start-up and shut-down • Micro-computer control panel is very user-friendly • Low-noise fans reduce radiated sound • Victaulic-grooved water connections reduce installation costs • Complies with ASHRAE Standard 90.1 on energy efficiency • Options are available upon request 2 JOHNSON CONTROLS Water-cooled Scroll Chillers Water-cooled chillers using scroll-compressor technology ranging from 50 to 200 tons. Standard features include: • Voltages: 200V, 230V, 380V, 460V, 380-415V/50Hz, 575V • Chilled-water supply range: 40 - 55°F; brine supply to 15°F • Single-point power connection reduces wiring costs • Non-fused disconnect switch simplifies installation and servicing • Control transformer eliminates separate control wiring • Micro-computer control panel is very user-friendly • Complies with ASHRAE Standard 90.1 on energy efficiency • Non-reversing heat pump function (leaving condenser temperature control) • Options are available upon request Need temporary cooling? If you need cooling while we are customizing your unit, Johnson Controls can provide a rental unit. We make available a wide range of products including chillers, rooftop units, air handlers, towers and peripheral equipment. Our service includes delivery, installation, start-up, maintenance, and financing. If interested in this option please contact the JCI Rental Department at: 1-800-JCI-RNTL (1800-524-7685) www.johnsoncontrols.com/rental Need more than the standard unit? Need Replacement Parts? If you need a chiller quickly but need some customization of features, Johnson Controls can make it happen. Customization features include: • Suction-pressure readouts • Service-Isolation valves • Hot gas by-pass • Brine cooling as low as 10°F • Functional witness testing • Hydronics package • Epoxy Coated Cond. Coils • Options are available upon request Your brand HVAC parts source for air cooled, water cooled, and absorption chillers. We are able to ship out the HVAC parts that you need as soon as possible. If you need items urgently (for a hospital, school or other critical application) we can prioritize this requirement and work with our supplier for expediting. If you have a need for replacement parts please contact the JCI Parts Department at : jOHNSON CONTROLS 1-800-932-1701 3 Ways to Reduce Your Risk, Expand Your Business and Increase Your Profits OPTION I Use Variable Speed Technology to Create Chiller Replacement Opportunities Compressor motor control via a variable frequency drive allows you as the installing contractor to give your customer more tonnage without changing the electrical power supply. Also, emergency generator size can be reduced when feeding chillers with variable speed compressors. For Example: Your customer has an existing chiller that produces 165 tons at ARI conditions. The MCA for this chiller is 374 amps and the existing wire and breaker size was installed to meet this MCA. Your customer is short on capacity during peak hours of the day. YORK has an YVAA0248CEV that produces 225 tons with an MCA of 374. This will give you an extra 61 tons without changing out the wires or breakers. On the other hand, if your customer doesn’t have a need for additional capacity, and the installation requires electrical power component upgrades, the first cost savings when using smaller breakers, wire and conduit is substantial. $310 Average Wire Savings Potential For a Smaller Circuit Breaker Frame Size $2,100 $3,500 OPTION II Use Energy Performance to Differentiate Your Replacement Offering The YORK Latitude variable speed air-cooled chiller allows you as the installing contractor to offer your customers a replacement alternative that is as much as 25% more efficient than existing chillers. For Example: Your customer wants to replace an existing 350-ton chiller. You as the installing contractor can offer either a standard efficiency chiller or the YORK optimized variable speed chiller. The optimized offering will save the customer over $17,000/year*. With this level of annual savings, you can offer your customer a $21,250 additive alternate with a 1.25 year simple payback. The price premium for the optimized offering is $7,000, which allows you to capture $14,250 of additional gross profit. *see the next page for the Average Energy Cost (AEC) calculation 4 JOHNSON CONTROLS Annual Savings / Average Energy Cost (AEC) Calculation Input Variables: IPLV = Integrated Part Load Value (kW/TON) = (12) / (IPLV EER) FLT = Full Load Tons (tons) ACL = Average Chiller Load (tons) = (FLT) x (0.58) RATE = Commercial Energy Cost ($/kWh) OH – Average Chiller Operating Hours (hrs) Output Functions: AEC = (IPLV) x (ACL) x (RATE) x (OH) Annual Savings = AEC Existing or Base Bid – AEC New Example Input Variables: IPLV Existing or Base Bid = 15.4 EER IPLV New = 19.0 EER FLT Existing or Base Bid = 350 tons FLT New = 350 tons RATE = $0.1016/kWh OH = 5000 hrs Calculations: AEC Existing or Base Bid = (IPLV) x (ACL) x (RATE) x (OH) AEC Existing or Base Bid = (12 / (IPLV EER)) x ((FLT) x (0.58)) x (RATE) x (OH) AEC Existing or Base Bid = (12 / 15.4 EER) x (350 tons x 0.58) x ($0.1016/kWh) x (5000 hrs) AEC Existing or Base Bid = $80,356.36 AEC New = (IPLV) x (ACL) x (RATE) x (OH) AEC New = (12 / (IPLV EER)) x ((FLT) x (0.58)) x (RATE) x (OH) AEC New = (12 / 19.0 EER) x (350 tons x 0.58) x ($0.1016/kWh) x (5000 hrs) AEC New = $65,130.95 Annual Savings = AEC Existing or Base Bid – AEC New Annual Savings = $80,356.36 - $65,130.95 Annual Savings = $15,225.41 / year jOHNSON CONTROLS 5 6 JOHNSON CONTROLS YCAL 15 to 65 Tons Air Cooled Scroll Chiller jOHNSON CONTROLS 7 8 JOHNSON CONTROLS YCAL Rigging WARNING ­— To ensure warranty coverage, this equipment must be commissioned and serviced by an authorized Johnson Controls Service Mechanic or a qualified service person experienced in chiller installation. Installation must comply with all applicable codes, particularly in regard to electrical wiring and other safety elements such as relief valves, HP cutout settings, design working pressures, and ventilation requirements consistent with the amount and type of refrigerant charge. Lethal voltages exist within the control panels. Before servicing, open and tag all disconnect switches. Installation Check List The following items must be checked before placing the units in operation. 1. Inspect the unit for shipping damage. 2. Rig Unit using spreader bars. 3. Open the unit only to install water piping system. Do not remove protective covers from water connections until piping is ready for attachment. Check water piping to ensure cleanliness. 4. Pipe unit using good piping practice (see ASHRAE handbook section 215 and 195). 5. Check to see that the unit is installed and operated within limitations (Refer to Operational and Voltage Limitations located in Section 1 of the YCAL Operations and Maintenance Guide [Form 150.62-NM8]). The following pages outline detailed procedures to be followed to install and startup the chiller. Handling These units are shipped as completely assembled units containing full operating charge, and care should be taken to avoid damage due to rough handling. WARNING —The unit should be lifted by inserting hooks through the holes provided in the unit base rails. Spreader bars should be used to avoid crushing the unit frame rails with lifting chains. Inspection EXAMPLE OF PROPER LIFTING Immediately upon receiving the unit, it should be inspected for possible damage which may have occurred during transit. If damage is evident, it should be noted in the carrier’s freight bill. A written request for inspection by the carrier’s agent should be made at once. See Instruction manual, Form 50.15-NM for more information and details. Location and Clearances These units are designed for outdoor installations on ground level, rooftop, or beside a building. Location should be selected for minimum sun exposure and to insure adequate supply of fresh air for the condenser. The units must be installed with sufficient clearances for air entrance to the condenser coil, for air discharge away from the condenser, and for servicing access. In installations where winter operation is intended and show accumulations are expected, additional height must be provided to ensure normal condenser air flow. Clearances are listed under Dimensions in Section 1 of the YCAL Operations and Maintenance Guide form 150.62-NM8. jOHNSON CONTROLS 9 AIR COOLED SCROLL CHILLER YCAL Style E - 15 to 65 TONS (R-410A) BENEFITS • Maintenance free, hermetic scroll compressor utilizes fewer moving parts to minimize breakdown •Components and circuitry designed for lower minimum circuit ampacities (MCA) to allow use of smaller wire for reduced power wiring costs • Electronic, digital-based controls ensure reliable, solid-state monitoring and control •Units ship with full ref. charge and undergo factory pressure and operational testing to minimize field setup time • Two refrigerant circuits on units over 35 tons allows redundant operation • Industry’s only 18-month air cooled warranty that covers all parts • Wide range of options to fit any design requirement. (Acoustical treatments, Hydrokit packages etc) UPGRADE OPTIONS •Remote Cooler • Power Options --> 200, 230, 380, 460, 575 (Not available on all models, refer to Engineering Guide): • Single Point Terminal Block, Non-fused Disconnect Switch, Circuit Breaker, Control Transformer • Control Options: • Low Ambient Kit extends operating range to 0 deg. F from +25 deg. F •Discharge Pressure Transducers and Readout Capability (standard) allows unit to sense and display discharge pressure • Low Temperature Brine for chilling below 30 deg. F •Motor Current Module allows monitoring of compressor motor current, provides extra protection against compressor reverse rotation, phase-loss and phase imbalance • Hot Gas Bypass for continuous, stable operation at capacities as low as 5% capacity •Service Isolation Valve - suction and discharge (ball type) isolation valves are added to unit per system; includes a system high pressure relief valve in compliance with ASHRAE 15 • Pre-coated, Post-coated Epoxy Dipped or Copper Fin condenser coils • Unit Enclosure Options: •Wire Panels (full unit-standard): coated, heavy gauge welded wire mesh mounted on exterior of unit to prevent unauthorized access •Louvered Panels (full unit): to protect condenser coils, visually screen internal components and prevent unauthorized access • Sound Attenuation: • Compressor Acoustic Sound Blanket • Ultra Quiet fans • Vibration Isolators - 1" spring, 2" spring or neoprene pad isolators for mounting under unit base rails 10 JOHNSON CONTROLS AIR COOLED SCROLL CHILLER YCAL Style E - 15 to 65 TONS PACKAGE DESCRIPTION: Cooler: •Shipped complete from the factory ready for field installation and use • Fully charged with HFC-410A and initial oil charge • Baked on powder paint • Heavy gauge, formed galvanized steel base • Operational and Pressure Tested •Equipped with a heater controlled by separate thermostat for freeze protection to –20 deg. F • Covered by closed cell foam insulation •Inlet and outlet are grooved for compatibility with field supplied victaulic connections Controls: Compressors: • Suction-gas cooled, hermetic scroll compressors •Large internal volume and oil reservoir provides greater liquid tolerance •Crankcase heaters for extra protection against liquid migration •All controls housed in a NEMA 3R/12 cabinet with gasket sealed, hinged & latched door • LCD, 40-character display with backlight • Color coded, sealed keypad •Standard controls permit operation from 25 to 125 deg F. Condenser: •Low noise, direct drive, maximum efficiency fans with corrosion resistant aluminum hub and composite blades; statically and dynamically balanced •Totally enclosed air over (TEAO) type fan motors, current protected and permanently sealed •Seamless, internally enhanced copper fin & tube coils arranged in staggered rows; mechanically expanded to full-height aluminum fins • Design Working Pressure 650 PSIG • Integral subcooling included jOHNSON CONTROLS 11 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0019EE46 15.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 37.0 6.3 Water 0.00010 3.3 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 1 18.6/18.6 114.0/114.0 2/1.3 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.0 / 2.9 14.6 / 4.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 1454 1481 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 44.9 60 50 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 60 50 60 1 (1)#14 - #2/0 39.8 114.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 17.6 1.0 18.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 50.0 12 Operating Condition Electrical Data Ambient (°F) 95.0 70.2 Part Load Rating Data Capacity (Tons) 15.4 9.1 Compressor kW 17.6 6.3 Unit Efficiency 10.0 / 2.9 16.0 / 4.7 JOHNSON CONTROLS jOHNSON CONTROLS LEFT END 44 5/16" BASE WIDTH B 8 5/16" 18 3/4" 11" (2) 3.0 X 1.50 RIGGING HOLES BOTH ENDS 2" VICTAULIC CONN (TYP) LIQUID IN BOTTOM OF PANEL VIEW B-B 7/8" TYP. AIR-COOLED SCROLL CHILLER MODEL: YCAL0019EE46 NOT FOR CONSTRUCTION Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 8 5/16" 2" VICTAULIC CONN (TYP) LIQUID OUT TO ACCESS PANEL 16 1/4" 11 5/8" B PRODUCT DRAWING 2 1/4" 46 1/16" 45 1/4" 3 15/16" 3 1/4" 6 3/4" X 13 3/4" 38 3/16" 2 1/4" 3 3/8" CONTROL PANEL R-410A CHILLER C G Y ORIGIN 6 1/8" CONTROL PANEL 44 3/8" END END CAP WIDTH 32 1/8" 1 1/16" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 1,454, OPERATING - 1,481. 3. CENTER OF GRAVITY FROM ORIGIN: X= 58.6", Y= 22.9" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 44 1/2" 15 5/8" 9 1/16" 374 FRONT VIEW 109 3/16" 74 1/2" 97 1/8" 5" 1 1/16" COMPR END (2) 3.0 X 1.50 RIGGING HOLES BOTH SIDES 340 365 A JOHNSON CONTROLS COMPANY (2) 7.0 X 2.25 FORKLIFT HOLES BOTH SIDES TOP VIEW 5/8" DIA MOUNTING HOLES(TYP) Date : Rev. Date : Form : 150.64-EG1 Dwg. Lev. : 03/05 Dwg. Scale : NTS 1" 17" 2 1/4" 402 MODEL: YCAL0019EE46 AHRI CAPACITY 15.4 TONS YCAL 15 TO 40 13 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0022EE46 18.7 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 44.8 4.9 Water 0.00010 3.6 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 1 20.0/20.0 125.0/125.0 2/1.3 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.0 / 2.9 15.5 / 4.5 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 1567 1597 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 48.1 60 60 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 60 60 60 1 (1)#14 - #2/0 42.6 125.0 Across the Line 48.1 Notes: Compressor kW Total Fan kW Total kW 21.5 1.0 22.5 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 50.0 14 Operating Condition Electrical Data Ambient (°F) 95.0 72.1 Part Load Rating Data Capacity (Tons) 18.7 11.5 Compressor kW 21.5 7.2 Unit Efficiency 10.0 / 2.9 16.9 / 5.0 JOHNSON CONTROLS jOHNSON CONTROLS LEFT END 44 5/16" BASE WIDTH B 8 5/16" 18 3/4" 11" (2) 3.0 X 1.50 RIGGING HOLES BOTH ENDS 2" VICTAULIC CONN (TYP) LIQUID IN BOTTOM OF PANEL VIEW B-B 7/8" TYP. AIR-COOLED SCROLL CHILLER MODEL: YCAL0022EE46 NOT FOR CONSTRUCTION Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 8 5/16" 2" VICTAULIC CONN (TYP) LIQUID OUT TO ACCESS PANEL 16 1/4" 11 5/8" B PRODUCT DRAWING 2 1/4" 46 1/16" 45 1/4" 3 15/16" 3 1/4" 6 3/4" X 13 3/4" 38 3/16" 2 1/4" 3 3/8" CONTROL PANEL R-410A CHILLER C G Y ORIGIN 6 1/8" CONTROL PANEL 44 3/8" END END CAP WIDTH 32 1/8" 1 1/16" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 1,567, OPERATING - 1,597. 3. CENTER OF GRAVITY FROM ORIGIN: X= 58.5", Y= 22.9" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 44 1/2" 15 5/8" 9 1/16" 403 FRONT VIEW 109 3/16" 74 1/2" 97 1/8" 5" 1 1/16" COMPR END (2) 3.0 X 1.50 RIGGING HOLES BOTH SIDES 366 394 A JOHNSON CONTROLS COMPANY (2) 7.0 X 2.25 FORKLIFT HOLES BOTH SIDES TOP VIEW 5/8" DIA MOUNTING HOLES(TYP) Date : Rev. Date : Form : 150.64-EG1 Dwg. Lev. : 03/05 Dwg. Scale : NTS 1" 17" 2 1/4" 434 MODEL: YCAL0022EE46 AHRI CAPACITY 18.7 TONS YCAL 15 TO 40 15 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0028EE46 25.6 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 61.3 8.9 Water 0.00010 2.5 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 1 23.1/26.9 150.0/187.0 2/4.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.1 / 3.0 13.4 / 3.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 1798 1835 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 64.7 100 80 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 90 80 90 1 (1)#14 - #2/0 58.0 187.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 27.5 3.0 30.5 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 50.8 16 Operating Condition Electrical Data Ambient (°F) 95.0 71.9 Part Load Rating Data Capacity (Tons) 25.6 15.7 Compressor kW 27.5 11.7 Unit Efficiency 10.1 / 3.0 14.3 / 4.2 JOHNSON CONTROLS jOHNSON CONTROLS 15 1/2" 49 1/4" B LEFT END 44 5/16" BASE WIDTH 19" B 8 5/16" 10 3/4" 8 1/2" AIR-COOLED SCROLL CHILLER MODEL: YCAL0028EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING (2) 3.0 X 1.50 RIGGING HOLES BOTH ENDS 2" VICTAULIC CONN (TYP) LIQUID IN VIEW B-B BOTTOM OF PANEL 7/8" TYP. Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 8 5/16" 2" VICTAULIC CONN (TYP) LIQUID OUT TO ACCESS PANEL 13 3/8" 2 1/4" 50 1/16" 3 15/16" 3 1/4" 6 3/4" 2 1/4" 3 3/8" CONTROL PANEL X Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 17 3/4" 42 1/8" C G NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING 1 1/16" SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED CONTROL BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE PANEL 44 3/8" DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE END END CAP OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; WIDTH HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL 32 1/8" PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; 6 1/8" TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 1,798, OPERATING - 1,835. 3. CENTER OF GRAVITY FROM ORIGIN: X= 63.1", Y= 22.9" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS ORIGIN IN CHILLED WATER PIPING NEAR THE EVAPORATOR. Y 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 1" 17" TOP VIEW 50 1/2" 15 5/8" 9" Date : Rev. Date : Form : 150.64-EG1 Dwg. Lev. : 03/05 Dwg. Scale : NTS FRONT VIEW 118 5/16" 105 1/16" 80 1/2" (2) 7.0 X 2.25 FORKLIFT HOLES BOTH SIDES 5" 1 1/16" COMPR END (2) 3.0 X 1.50 RIGGING HOLES BOTH SIDES 423 456 A JOHNSON CONTROLS COMPANY 5/8" DIA MOUNTING HOLES(TYP) R-410A CHILLER 460 1 7/8" 495 MODEL: YCAL0028EE46 AHRI CAPACITY 25.6 TONS YCAL 15 TO 40 17 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0033EE46 28.6 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 68.4 11.0 Water 0.00010 5.2 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 1 26.9/26.9 187.0/187.0 2/4.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.5 / 3.1 14.5 / 4.2 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 2034 2077 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 66.7 100 80 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 90 80 90 1 (1)#14 - #2/0 61.8 187.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 29.6 3.0 32.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 50.0 18 Operating Condition Electrical Data Ambient (°F) 95.0 70.0 Part Load Rating Data Capacity (Tons) 28.6 16.6 Compressor kW 29.6 11.2 Unit Efficiency 10.5 / 3.1 15.7 / 4.6 JOHNSON CONTROLS jOHNSON CONTROLS 15 1/2" 49 1/4" B LEFT END 44 5/16" BASE WIDTH 19" B 8 5/16" 10 3/4" 8 1/2" AIR-COOLED SCROLL CHILLER MODEL: YCAL0033EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING (2) 3.0 X 1.50 RIGGING HOLES BOTH ENDS 2" VICTAULIC CONN (TYP) LIQUID IN VIEW B-B BOTTOM OF PANEL 7/8" TYP. Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 8 5/16" 2" VICTAULIC CONN (TYP) LIQUID OUT TO ACCESS PANEL 13 3/8" 2 1/4" 50 1/16" 3 15/16" 3 1/4" 6 3/4" 2 1/4" 3 3/8" CONTROL PANEL X Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 17 3/4" 42 1/8" C G NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING 1 1/16" SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED CONTROL BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE PANEL 44 3/8" DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE END END CAP OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; WIDTH HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL 32 1/8" PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; 6 1/8" TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 2,034, OPERATING - 2,077. 3. CENTER OF GRAVITY FROM ORIGIN: X= 67.1", Y= 23.1" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS ORIGIN IN CHILLED WATER PIPING NEAR THE EVAPORATOR. Y 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 1" 17" TOP VIEW 50 1/2" 15 5/8" 9" Date : Rev. Date : Form : 150.64-EG1 Dwg. Lev. : 03/05 Dwg. Scale : NTS FRONT VIEW 118 5/16" 105 1/16" 80 1/2" (2) 7.0 X 2.25 FORKLIFT HOLES BOTH SIDES 5" 1 1/16" COMPR END (2) 3.0 X 1.50 RIGGING HOLES BOTH SIDES 516 565 A JOHNSON CONTROLS COMPANY 5/8" DIA MOUNTING HOLES(TYP) R-410A CHILLER 475 1 7/8" 520 MODEL: YCAL0033EE46 AHRI CAPACITY 28.6 TONS YCAL 15 TO 40 19 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0043EE46 37.2 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 89.2 6.1 Water 0.00010 2.7 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 20.0/20.0 125.0/125.0 2/3.4 1 20.0/20.0 125.0/125.0 2/3.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.1 / 3.0 14.5 / 4.2 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 2942 2967 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 99.2 150 110 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 110 110 110 1 (1)#14 - #2/0 93.7 125.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 38.8 5.6 44.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 75.0 50.0 25.0 20 Operating Condition Electrical Data Ambient (°F) 95.0 83.3 69.0 55.0 Part Load Rating Data Capacity (Tons) 37.2 30.0 21.1 11.5 Compressor kW 38.8 24.4 14.2 6.6 Unit Efficiency 10.1 / 3.0 12.0 / 3.5 14.9 / 4.4 17.3 / 5.1 JOHNSON CONTROLS jOHNSON CONTROLS 46 15/16" LIQUID IN LEFT END 45 1/8" 90 1/4" BASE WIDTH LIQUID OUT 3" VICTAULIC (TYP) VIEW B-B BOTTOM OF PANEL 7/8" TYP. 12 5/8" 25 3/16" 9 7/8" 15 3/4" ELECTRICAL ACCESS PANEL AIR-COOLED SCROLL CHILLER MODEL: YCAL0043EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 47 3/4" 3 15/16" 6 3/4" 3 1/4" C G X 15 1/16" 13 5/8" 25 3/8" 5 5/16" Y 18 1/2" ORIGIN 45 1/8" B COOLER END 1 1/16" 90 9/16" END CAP WIDTH Sold To : Cust Purch Order# : York Contract# : UNIT TAG: NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 2,942, OPERATING - 2,967. 3. CENTER OF GRAVITY FROM ORIGIN: X= 59.6", Y= 43.6" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 925 862 B CONTROLPANEL TOP VIEW Date : Rev. Date : Form : 150.62-EG1 Dwg. Lev. : 01/02 Dwg. Scale : NTS 13 15/16" 611 569 9 13/16" 1 1/16" COIL END A JOHNSON CONTROLS COMPANY FRONT VIEW 144 13/16" TWO LIFTING HOLES BOTH SIDES 38" 9 13/16" 5/8" DIA MOUNTING HOLES(TYP) MODEL: YCAL0043EE46 AHRI CAPACITY 37.2 TONS YCAL 15 TO 40 21 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0046EE46 39.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 94.5 5.1 Water 0.00010 3.5 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 20.0/20.0 125.0/125.0 2/3.4 1 20.7/20.7 125.0/125.0 2/3.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.2 / 3.0 14.7 / 4.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 2968 3000 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 100.8 150 110 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 110 110 110 1 (1)#14 - #2/0 95.1 125.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 41.0 5.6 46.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 73.2 50.0 23.2 22 Operating Condition Electrical Data Ambient (°F) 95.0 82.9 69.1 55.0 Part Load Rating Data Capacity (Tons) 39.4 31.5 22.4 11.6 Compressor kW 41.0 25.2 14.9 6.5 Unit Efficiency 10.2 / 3.0 12.3 / 3.6 15.2 / 4.5 17.5 / 5.1 JOHNSON CONTROLS jOHNSON CONTROLS 46 15/16" 45 1/8" LEFT END 12 5/8" AIR-COOLED SCROLL CHILLER MODEL: YCAL0046EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 15 3/4" 25 3/16" ELECTRICAL ACCESS PANEL 9 7/8" LIQUID IN 90 1/4" BASE WIDTH LIQUID OUT 3" VICTAULIC (TYP) VIEW B-B BOTTOM OF PANEL 7/8" TYP. Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 47 3/4" 3 15/16" 6 3/4" 3 1/4" X 15 1/16" 13 5/8" 25 3/8" 5 5/16" C G Y 16 11/16" ORIGIN 45 1/8" B COOLER END 1 1/16" 90 9/16" END CAP WIDTH Sold To : Cust Purch Order# : York Contract# : UNIT TAG: NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 2,968, OPERATING - 3,000. 3. CENTER OF GRAVITY FROM ORIGIN: X= 59.2", Y= 43.5" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 941 875 B CONTROLPANEL TOP VIEW Date : Rev. Date : Form : 150.62-EG1 Dwg. Lev. : 01/02 Dwg. Scale : NTS 13 15/16" 613 570 9 13/16" 1 1/16" COIL END A JOHNSON CONTROLS COMPANY FRONT VIEW 144 13/16" TWO LIFTING HOLES BOTH SIDES 38" 9 13/16" 5/8" DIA MOUNTING HOLES(TYP) MODEL: YCAL0046EE46 AHRI CAPACITY 39.4 TONS YCAL 15 TO 40 23 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0052EE46 46.2 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 110.8 9.2 Water 0.00010 3.5 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 23.1/23.1 150.0/150.0 2/4.0 1 23.1/23.1 150.0/150.0 2/4.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.2 / 3.0 15.1 / 4.4 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 3170 3208 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 114.2 150 125 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 125 125 125 1 (1)#14 - #2/0 108.4 150.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 47.9 6.7 54.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 75.0 50.0 25.0 24 Operating Condition Electrical Data Ambient (°F) 95.0 83.4 69.5 55.0 Part Load Rating Data Capacity (Tons) 46.2 37.3 26.6 15.1 Compressor kW 47.9 30.7 17.6 7.8 Unit Efficiency 10.2 / 3.0 12.0 / 3.5 15.2 / 4.5 19.1 / 5.6 JOHNSON CONTROLS jOHNSON CONTROLS 61 7/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END LIQUID OUT 3" VICTAULIC (TYP) VIEW B-B BOTTOM OF PANEL 7/8" TYP. 12 5/8" 25 3/16" 9 13/16" 15 3/4" ELECTRICAL ACCESS PANEL LIQUID IN AIR-COOLED SCROLL CHILLER MODEL: YCAL0052EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING Project Name : Contractors Guide Location : Engineer : Contractor : For : POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 62 5/8" 3 15/16" 6 3/4" 3 1/4" X 15 1/16" 13 5/8" 25 3/8" B Sold To : Cust Purch Order# : York Contract# : UNIT TAG: C G Y 18 1/2" ORIGIN 9 13/16" B TOP VIEW Date : Rev. Date : Form : 150.62-EG1 Dwg. Lev. : 01/02 Dwg. Scale : NTS FRONT VIEW 144 13/16" 713 623 1 1/16" COIL END A JOHNSON CONTROLS COMPANY 13 15/16" 9 13/16" 5/8" DIA MOUNTING HOLES(TYP) TWO LIFTING HOLES BOTH SIDES CONTROL PANEL 5 5/16" 38" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED 873 1 1/16" PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE COOLER DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE END OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; 90 9/16" TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. END CAP NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. WIDTH 2. WEIGHTS (LB):SHIPPING - 3,170, OPERATING - 3,208. 3. CENTER OF GRAVITY FROM ORIGIN: X= 61.9", Y= 42.2" . 45 1/8" 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 999 MODEL: YCAL0052EE46 AHRI CAPACITY 46.2 TONS YCAL 41 TO 65 25 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0056EE46 56.2 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 134.7 9.9 Water 0.00010 4.1 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 26.9/26.9 187.0/187.0 2/4.0 1 26.9/26.9 187.0/187.0 2/4.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.1 / 3.0 14.7 / 4.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 3206 3244 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 130.3 150 150 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 150 150 150 1 (1)#14 - #2/0 123.6 187.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 60.3 6.7 67.0 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 75.0 50.0 25.0 26 Operating Condition Electrical Data Ambient (°F) 95.0 83.6 69.4 55.0 Part Load Rating Data Capacity (Tons) 56.2 45.5 32.2 18.0 Compressor kW 60.3 38.8 22.6 10.2 Unit Efficiency 10.1 / 3.0 12.0 / 3.5 14.9 / 4.4 18.1 / 5.3 JOHNSON CONTROLS jOHNSON CONTROLS 61 7/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END LIQUID OUT 3" VICTAULIC (TYP) VIEW B-B BOTTOM OF PANEL 7/8" TYP. AIR-COOLED SCROLL CHILLER MODEL: YCAL0056EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 15 3/4" 12 5/8" 9 7/8" Project Name : Contractors Guide Location : Engineer : Contractor : For : 25 3/16" ELECTRICAL ACCESS PANEL LIQUID IN POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 62 5/8" 3 15/16" 6 3/4" 3 1/4" X 15 1/16" 28 9/16" 25 3/8" B Sold To : Cust Purch Order# : York Contract# : UNIT TAG: C G Y 16 11/16" ORIGIN 9 13/16" B TOP VIEW Date : Rev. Date : Form : 150.62-EG1 Dwg. Lev. : 01/02 Dwg. Scale : NTS FRONT VIEW 144 13/16" 715 625 1 1/16" COIL END A JOHNSON CONTROLS COMPANY 14" 9 13/16" 5/8" DIA MOUNTING HOLES(TYP) TWO LIFTING HOLES BOTH SIDES CONTROL PANEL 5 3/16" 38" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED 889 1 1/16" PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE COOLER DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE END OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; 90 9/16" TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. END CAP NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. WIDTH 2. WEIGHTS (LB):SHIPPING - 3,206, OPERATING - 3,244. 3. CENTER OF GRAVITY FROM ORIGIN: X= 61.5", Y= 42.2" . 45 1/8" 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 1,015 MODEL: YCAL0056EE46 AHRI CAPACITY 56.2 TONS YCAL 41 TO 65 27 Air Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCAL0066EE46 66.1 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume. (gal) 54.0 44.0 158.4 8.3 Water 0.00010 4.9 Circuit Compressor RLA Compressor Start Current (LRA) Fan QTY/FLA (each) Condenser Data Ambient Temp. (°F) Altitude (ft.) Min. Ambient Temp. (°F) Max. Ambient Temp. (°F) 95.0 0 25.0 115.0 Electrical Data 2 26.9/26.9 187.0/187.0 2/1.3 1 33.9/33.9 250.0/250.0 2/4.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 10.1 / 3.0 15.1 / 4.4 Rigging Wt. (lbs.) Operating Wt. (lbs.) 3 4097 4142 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 146.0 200 175 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Lugs Per Phase* Wire Range (Lug Size) Total Amps Inrush (PW) Amps Starter Type 175 175 175 1 (1)#6 - 350 137.6 250.0 Across the Line Notes: Compressor kW Total Fan kW Total kW 72.1 6.7 78.8 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Installing contractor must include vent and drain accommodations in the chilled water piping near the evaporator. A strainer, preferably 40 mesh, must be installed in the cooler inlet just ahead of the cooler. This is important to protect the cooler from the entrance of large particles which could cause damage to the evaporator. Load % 100.0 71.5 50.0 21.5 28 Operating Condition Electrical Data Ambient (°F) 95.0 82.6 69.3 55.0 Part Load Rating Data Capacity (Tons) 66.1 52.5 37.8 18.5 Compressor kW 72.1 42.2 26.6 10.3 Unit Efficiency 10.1 / 3.0 12.9 / 3.8 15.2 / 4.5 18.5 / 5.4 JOHNSON CONTROLS jOHNSON CONTROLS 61 7/8" 43 1/8" 90 1/4" BASE WIDTH LEFT END LIQUID OUT 3" VICTAULIC (TYP) VIEW B-B BOTTOM OF PANEL 7/8" TYP. AIR-COOLED SCROLL CHILLER MODEL: YCAL0066EE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 15 3/4" 12 5/8" 9 3/4" Project Name : Contractors Guide Location : Engineer : Contractor : For : 25 1/16" ELECTRICAL ACCESS PANEL LIQUID IN POWER: SINGLE POINT SUPPLY WITH TERMINAL BLOCK 62 5/8" 3 15/16" 6 3/4" 3 1/4" X 15 1/16" 28 9/16" 25 3/8" B Sold To : Cust Purch Order# : York Contract# : UNIT TAG: C G Y 12 13/16" ORIGIN 9 13/16" B TOP VIEW Date : Rev. Date : Form : 150.62-EG1 Dwg. Lev. : 01/02 Dwg. Scale : NTS FRONT VIEW 153 5/8" 776 768 1 1/16" COIL END A JOHNSON CONTROLS COMPANY 16" 9 13/16" 5/8" DIA MOUNTING HOLES(TYP) TWO LIFTING HOLES BOTH SIDES CONTROL PANEL 5 3/16" 38" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING 1,292 SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED 1 1/16" PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE COOLER DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE END OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: COIL SIDE - 6' COMPRESSOR SIDE - 4'; CONTROL SIDE - 6'; 90 9/16" TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. END CAP NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. WIDTH 2. WEIGHTS (LB):SHIPPING - 4,097, OPERATING - 4,142. 3. CENTER OF GRAVITY FROM ORIGIN: X= 59.7", Y= 44.9" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS 43 1/8" IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 5. A STRAINER, PREFERABLY 40 MESH, MUST BE INSTALLED IN THE COOLER INLET JUST AHEAD OF THE COOLER. THIS IS IMPORTANT TO PROTECT THE COOLER FROM THE ENTRANCE OF LARGE PARTICLES WHICH COULD CAUSE DAMAGE TO THE EVAPORATOR. 1,306 MODEL: YCAL0066EE46 AHRI CAPACITY 66.1 TONS YCAL 41 TO 65 29 30 JOHNSON CONTROLS YLAA 70 to 175 Tons Air Cooled Scroll Chiller jOHNSON CONTROLS 31 32 JOHNSON CONTROLS YLAA RIGGING Typical Lifting Arrangement - 8 Fan Models Use spreader bars to avoid lifting chains hitting the chiller. CAUTION — Never lift the chiller using a forklift or by hooking to the top rails. Use only the lifting holes provided. Lifting instructions are placed on a label on the chiller and on the shipping bag. Typical Lifting Arrangement - 4 Fan Models jOHNSON CONTROLS 33 AIR COOLED SCROLL CHILLER YLAA - 70 to 175 TONS BENEFITS • Optimized design for R-410A refrigerant (No EPA Phase out date) •Available in 2-tiers of efficiency: •Standard Efficiency: 9.6 – 10.0 EER •High Efficiency: 10.1 an above EER •Best Part Load Efficiency with an IPLV as high as 15.9. •The YLAA always qualifies for LEED credit through Enhanced Refrigerant Management. •This chiller utilizes 30-50% less refrigerant than conventional scroll chiller design. •Standard ambient operation from 30 to 115-deg F •Maintenance free, hermetic scroll compressor utilizes fewer moving parts to minimize breakdown •Components and circuitry designed for lower minimum circuit ampacities (MCA) to allow use of smaller wire for reduced power wiring costs •Electronic, digital-based controls ensure reliable, solid-state monitoring and control •Units ship evacuated with initial oil charge and undergo factory pressure and operational testing to minimize field setup time •Two refrigerant circuits allows redundant operation. •Industry’s only 18-month air cooled warranty that covers all parts •Wide range of options to fit any design requirement. (Acoustical treatments, Hydrokit packages etc) UPGRADE OPTIONS •Remote Cooler •Power Options --> 200, 230, 380, 460, 575 (Not available on all models, refer to Engineering Guide): •Single Point Terminal Block, Terminal Block with Individual Circuit Breakers, Circuit Breaker, Non-fused Disconnect Switch or Non-fused Disconnect Switch with Individual System Circuit Breakers •Control Options: Low Ambient Kit extends operating range to 0 deg. F from +30 deg. F •Discharge Pressure Transducers and Readout Capability allows unit to sense and display discharge pressure •Low Temperature Brine for chilling below 30 deg. F (which includes Electronic Expansion Valve) •Motor Current Module allows monitoring of compressor motor current, provides extra protection against compressor reverse rotation, phase-loss and phase imbalance •Hot Gas Bypass for continuous, stable operation at capacities as low as 5% capacity •Service Isolation Valve - suction and discharge (ball type) isolation valves are added to unit per system; includes a system high pressure relief valve in compliance with ASHRAE 15 •Post-coated Epoxy Dipped •Unit Enclosure Options: •Wire Panels (full unit): coated, heavy gauge welded wire mesh mounted on exterior of unit to prevent unauthorized access •Louvered Panels (condenser coils only): louvered panels mounted over exterior condenser coil faces to protect coils •Louvered Panels (full unit): to protect condenser coils, visually screen internal components and prevent unauthorized access •Louvered (condensers)/Wire Panels (mechanicals): Louvered steel panels on external condenser coil faces, heavy-gauge welded-wire mesh around base •Sound Attenuation: •Compressor Acoustic Sound Blanket •Ultra Quiet fans •Vibration Isolators - 1" spring, 2" spring or neoprene pad isolators for mounting under unit base rails 34 JOHNSON CONTROLS AIR COOLED SCROLL CHILLER YLAA - 70 to 175 TONS PACKAGE DESCRIPTION: Evaporator: •Shipped complete from the factory ready for field installation and use • Fully charged with HFC-410A and initial oil charge • Baked on powder paint • Heavy gauge, formed galvanized steel base • Operational and Pressure Tested •Equipped with a heater controlled by separate thermostat for freeze protection to –20 deg. F •Covered by closed cell foam insulation •Inlet and outlet are grooved for compatibility with field supplied victaulic connections Refrigerant Circuit: Compressors: •Suction-gas cooled, hermetic scroll compressors •Large internal volume and oil reservoir provides greater liquid tolerance •Crankcase heaters for extra protection against liquid migration •Independent circuits per compressor •Each refrigerant circuit includes: liquid line shutoff valve with charging port, low side pressure relief device, filter-drier, solenoid valve, sight glass with moisture indicator, thermostatic expansion valves, and flexible, closed-cell foam insulated suction line and suction pressure transducer. Condenser: •Low noise, direct drive, maximum efficiency fans with corrosion resistant aluminum hub and composite blades; statically and dynamically balanced •The fan motors are Totally Enclosed Air-Over, current protected. They feature ball bearings that are double-sealed and permanently lubricated. •Condenser coils are made of a single material to avoid galvanic corrosion due to dissimilar metals. Coils and headers are brazed as one piece. •Design Working Pressure 650 PSIG •Integral subcooling included jOHNSON CONTROLS Controls: •All controls housed in a NEMA 3R/12 cabinet with gasket sealed, hinged & latched door • LCD, 40-character display with backlight • Color coded, sealed keypad •Standard controls permit operation from 30 to 115 deg F. 35 Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 36 YLAA-B0070SE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 71.8 84.8 10.2 16 16 87 3.3 Plate Heat Exchanger 5.4 Water 54 44 38.7 / 38.7 171.2 11.4 0.0001 3" 95 122.5 / 122.5 4 0 59329 6.7 460-3-60 / 414-506 160 175 175 1 #4 - 500 kcmil 3578 3623 101 116.1 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0070SE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" ORIGIN 3 1/4" C G Y X 76 5/8" 23 3/16" UNIT0 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 732 5 5/8" 1,030 114 11/16" - FRAME LENGTH 121 11/16" - OVERALL LENGTH 23 3/16" 19 5/8" 1,087 774 46 3/8" Date : 12/18/2012 11:37:46 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 3,578, OPERATING - 3,622. 3. CENTER OF GRAVITY FROM ORIGIN: X= 56.8", Y= 51.3" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 10" jOHNSON CONTROLS 42 11/16" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0070SE AHRI CAPACITY 71.8 TONS YLAA 70 TO 90 37 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 38 YLAA-B0080SE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 77.7 94.4 9.9 15.4 15.4 88 3.3 Plate Heat Exchanger 6.7 Water 54 44 38.7 / 39 185.4 9 0.0001 3" 95 126.1 / 122.9 4 0 59329 6.7 460-3-60 / 414-506 173 200 200 1 #4 - 500 kcmil 3898 3954 106 116.1 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0080SE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" ORIGIN 3 1/4" C G Y X 76 5/8" 23 3/16" UNIT0 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 750 5 5/8" 1,135 114 11/16" - FRAME LENGTH 121 11/16" - OVERALL LENGTH 23 3/16" 19 5/8" 1,246 822 46 3/8" Date : 12/18/2012 11:39:31 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 3,898, OPERATING - 3,953. 3. CENTER OF GRAVITY FROM ORIGIN: X= 56.1", Y= 52.9" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 10" jOHNSON CONTROLS 42 11/16" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0080SE AHRI CAPACITY 77.7 TONS YLAA 70 TO 90 39 1 1/4" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 40 YLAA-B0090SE 5 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 83.9 103.4 9.7 15.5 15.5 88 3.3 Plate Heat Exchanger 8.8 Water 54 44 39.4 / 39.4 199.7 7 0.0001 3" 95 126.1 / 127.2 4 0 59329 6.7 460-3-60 / 414-506 192 225 225 1 #4 - 500 kcmil 4169 4241 115 116.1 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0090SE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" 3" INLET 3" OUTLET ORIGIN 3 1/4" C G Y X 76 5/8" 23 3/16" UNIT0 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 831 5 5/8" 1,310 114 11/16" - FRAME LENGTH 121 11/16" - OVERALL LENGTH 23 3/16" 19 5/8" 1,285 816 46 3/8" Date : 12/18/2012 11:52:29 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 4,169, OPERATING - 4,242. 3. CENTER OF GRAVITY FROM ORIGIN: X= 58.1", Y= 53.7" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 10" jOHNSON CONTROLS 42 11/16" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0090SE AHRI CAPACITY 83.9 TONS YLAA 70 TO 90 41 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 42 YLAA-B0091HE 4 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 88.2 98.3 10.8 15 14.9 88 3.3 Plate Heat Exchanger 8.8 Water 54 44 39.2 / 39.2 210.8 7.7 0.0001 3" 95 117.7 / 117.7 6 0 88993 10.1 460-3-60 / 414-506 200 250 225 1 #4 - 500 kcmil 4718 4791 115 142.7 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0091HE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" 42 11/16" ORIGIN NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 4,718, OPERATING - 4,791. 3. CENTER OF GRAVITY FROM ORIGIN: X= 67.8", Y= 52.1" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3 1/4" C G Y 884 571 X 23 5/16" 47 3/8" UNIT1 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 142 1/4" - FRAME LENGTH 149 5/16" - OVERALL LENGTH 69 3/4" 23 1/8" 7 11/16" 1,290 840 5 5/8" 672 534 46 3/8" Date : 12/18/2012 11:54:27 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" jOHNSON CONTROLS 10" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0091HE AHRI CAPACITY 88.2 TONS YLAA 91 TO 130 43 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 44 YLAA-B0100SE 5 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 95.8 119.1 9.7 14.3 14.3 88 3.3 Plate Heat Exchanger 8.8 Water 54 44 39.6 / 38.5 228.2 9 0.0001 3" 95 122.7 / 123.6 5 0 74161 8.4 460-3-60 / 414-506 223 250 250 1 #4 - 500 kcmil 4791 4864 112 142.7 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0100SE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" 42 11/16" ORIGIN NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 4,791, OPERATING - 4,863. 3. CENTER OF GRAVITY FROM ORIGIN: X= 69.6", Y= 53.5" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3 1/4" C G Y 800 542 X 23 5/16" 47 3/8" UNIT1 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 142 1/4" - FRAME LENGTH 149 5/16" - OVERALL LENGTH 69 3/4" 23 1/8" 7 11/16" 1,459 836 5 5/8" 703 520 46 3/8" Date : 12/18/2012 12:55:43 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" jOHNSON CONTROLS 10" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0100SE AHRI CAPACITY 95.8 TONS YLAA 91 TO 130 45 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 46 YLAA-B0101HE 5 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 98.5 116.1 10.2 15.4 15.4 89 3.3 Plate Heat Exchanger 8.8 Water 54 44 39.6 / 38.1 234.6 9.4 0.0001 3" 95 125.2 / 117.7 6 0 88993 10.1 460-3-60 / 414-506 227 250 250 1 #4 - 500 kcmil 4954 5026 126 142.7 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0101HE46 NOT FOR CONSTRUCTION Project Name : YLAA Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT 81 13/16" 42 11/16" ORIGIN NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 4,954, OPERATING - 5,027. 3. CENTER OF GRAVITY FROM ORIGIN: X= 69.8", Y= 53.2" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3 1/4" C G Y 818 560 X 23 5/16" 47 3/8" UNIT1 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 142 1/4" - FRAME LENGTH 149 5/16" - OVERALL LENGTH 69 3/4" 23 1/8" 7 11/16" 1,501 875 5 5/8" 728 545 46 3/8" Date : 12/18/2012 12:58:34 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 1/2" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" jOHNSON CONTROLS 10" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0101HE AHRI CAPACITY 98.5 TONS YLAA 91 TO 130 47 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 48 YLAA-B0115SE 4 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 113.9 140.9 9.7 14.6 14.6 88 3.3 Plate Heat Exchanger 8.8 Water 54 44 38.3 / 38.3 272.6 12.4 0.0001 3" 95 124 / 124 6 0 88993 10.1 460-3-60 / 414-506 256 300 300 1 #4 - 500 kcmil 5029 5101 119 142.7 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0115SE46 NOT FOR CONSTRUCTION ORIGIN 81 13/16" 42 11/16" Project Name : New Project Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 5,029, OPERATING - 5,102. 3. CENTER OF GRAVITY FROM ORIGIN: X= 68", Y= 53.5" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3 1/4" C G Y 941 582 X 23 5/16" 47 3/8" UNIT0 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 142 1/4" - FRAME LENGTH 149 5/16" - OVERALL LENGTH 69 3/4" 23 1/8" 7 11/16" 1,442 866 5 5/8" 728 545 46 1/2" Date : 12/11/2012 8:18:19 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 3/8" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" jOHNSON CONTROLS 10" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0115SE AHRI CAPACITY 113.9 TONS YLAA 91 TO 130 49 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Cooling Capacity Total Power Input EER IPLV NPLV Sound Pressure (Hemispherical Method) Sound Pressure Measured at Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Wire Lugs Per Phase Wire Range (Lug Size) Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height 50 YLAA-B0120SE 4 Scroll - Hermetic 2 TR kW EER EER EER dB(A) ft USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in °F °F ft cfm kW A A A lb lb lb in in in R410A 119.6 143.3 10 14.8 14.8 88 3.3 Plate Heat Exchanger 13.2 Water 54 44 40.6 / 40.6 285.3 8.4 0.0001 3" 95 125.1 / 125.1 6 0 88993 10.1 460-3-60 / 414-506 256 300 300 1 #4 - 500 kcmil 5183 5293 128 142.7 88.3 94.2 JOHNSON CONTROLS MODEL: YLAA0120SE46 NOT FOR CONSTRUCTION ORIGIN 81 13/16" 42 11/16" Project Name : New Project Location : Engineer : Contractor : For : 88 5/16" - FRAME WIDTH 88 13/16" - OVERALL WIDTH PRODUCT DRAWING 94 3/8" - OVERALL HEIGHT 88 5/8" - FRAME HEIGHT NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 5,183, OPERATING - 5,293. 3. CENTER OF GRAVITY FROM ORIGIN: X= 69.5", Y= 53.2" . 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3 1/4" C G Y 937 578 X 23 5/16" 47 3/8" UNIT0 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 142 1/4" - FRAME LENGTH 149 5/16" - OVERALL LENGTH 69 3/4" 23 1/8" 7 11/16" 1,486 906 5 5/8" 789 600 46 1/2" Date : 12/11/2012 8:21:24 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 3/8" A JOHNSON CONTROLS COMPANY 3" OUTLET 3" INLET CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" jOHNSON CONTROLS 10" 5/8" DIA MOUNTING HOLES (TYP) MODEL: YLAA-B0120SE AHRI CAPACITY 119.6 TONS YLAA 91 TO 130 51 1 1/16" Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Net Cooling Capacity Total Power Input EER IPLV NPLV Sound Power Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Min Fluid Flow Rate Max Fluid Flow Rate Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power YLAA-B0136SE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in USGPM USGPM °F °F ft cfm kW Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Unit Short Circuit Current Withstand Wire Lugs Per Phase Wire Range (Lug Size) A A A [kA] Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height Software Version lb lb lb in in in R410A 129.9 154.3 10.1 15.5 16.5 93 Plate Heat Exchanger 10 Water 54 44 37.2 / 39.6 310.7 13.4 0.0001 4" 120 625 95 126.9 / 113.2 8 0 120776 13.4 460-3-60 / 414-506 285 300 300 5 1 #4 - 500 kcmil 6103 6187 146 187.7 88.3 94.2 YW13.02a Certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI Directory at www.ahridirectory.org Auxiliary components included in total KW - Oil heaters, Chiller controls. Auxiliary power is already included in the compressor and fan power 52 JOHNSON CONTROLS MODEL: YLAA0136SE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88 1/4" - FRAME WIDTH 88 3/4" - OVERALL WIDTH Y C G 23 3/16" ORIGIN 3 5/16" Project Name : cg ylaa Location : Engineer : Contractor : For : 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3. CENTER OF GRAVITY FROM ORIGIN: X= 82.6"; Y= 51.9" . 2. WEIGHTS (LB): SHIPPING - 6,102; OPERATING - 6,186. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6' CONTROL PANEL TO WALL - 4' TOP - NO OBSTRUCTIONS ALLOWED DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THAN ONE ADJACENT WALL MAY BE HIGHER THAN THE UNIT. 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. 94 3/8" - OVERALL HEIGHT 88 1/2" - FRAME HEIGHT 81 5/8" jOHNSON CONTROLS X 6 1/2" 69" 58" 59 13/16" 75 1/2" UNIT1 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 186 1/4" - FRAME LENGTH 5/8" DIA MOUNTING HOLES (TYP) 1 3/16" 4" OUTLET 4" INLET Date : 5/21/2013 15:16:15 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 5 3/8" 46 3/8" A JOHNSON CONTROLS COMPANY CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" 10" NOTES: MODEL: YLAAB0136SE AHRI CAPACITY 129.9 TONS YLAA 91 TO 130 53 Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Net Cooling Capacity Total Power Input EER IPLV NPLV Sound Power Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Min Fluid Flow Rate Max Fluid Flow Rate Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power YLAA-B0142HE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in USGPM USGPM °F °F ft cfm kW Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Unit Short Circuit Current Withstand Wire Lugs Per Phase Wire Range (Lug Size) A A A [kA] Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height Software Version lb lb lb in in in R410A 132.1 152.3 10.4 14.4 16.2 96 Plate Heat Exchanger 13.2 Water 54 44 39.2 / 41.5 315.4 10 0.0001 4" 150 625 95 123.1 / 116.4 8 0 120776 13.4 460-3-60 / 414-506 285 300 300 5 1 #4 - 500 kcmil 6333 6444 157 187.7 88.3 94.2 YW13.02a Certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI Directory at www.ahridirectory.org Auxiliary components included in total KW - Oil heaters, Chiller controls. Auxiliary power is already included in the compressor and fan power 54 JOHNSON CONTROLS MODEL: YLAA0142HE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88 1/4" - FRAME WIDTH 88 3/4" - OVERALL WIDTH Y C G 23 3/16" ORIGIN 3 5/16" Project Name : cg ylaa Location : Engineer : Contractor : For : 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3. CENTER OF GRAVITY FROM ORIGIN: X= 83"; Y= 52.1" . 2. WEIGHTS (LB): SHIPPING - 6,334; OPERATING - 6,444. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6' CONTROL PANEL TO WALL - 4' TOP - NO OBSTRUCTIONS ALLOWED DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THAN ONE ADJACENT WALL MAY BE HIGHER THAN THE UNIT. 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. 94 3/8" - OVERALL HEIGHT 88 1/2" - FRAME HEIGHT 81 5/8" jOHNSON CONTROLS X 6 1/2" 69" 58" 59 13/16" 75 1/2" UNIT2 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 186 1/4" - FRAME LENGTH 5/8" DIA MOUNTING HOLES (TYP) 1 3/16" 4" OUTLET 4" INLET Date : 5/21/2013 15:16:37 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 5 3/8" 46 3/8" A JOHNSON CONTROLS COMPANY CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 13/16" 32 3/8" 10" NOTES: MODEL: YLAAB0142HE AHRI CAPACITY 132.1 TONS YLAA 131 TO 175 55 Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Net Cooling Capacity Total Power Input EER IPLV NPLV Sound Power Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Min Fluid Flow Rate Max Fluid Flow Rate Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power YLAA-B0156HE 5 Scroll - Hermetic 2 TR kW EER EER EER dB(A) USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in USGPM USGPM °F °F ft cfm kW Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Unit Short Circuit Current Withstand Wire Lugs Per Phase Wire Range (Lug Size) A A A [kA] Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height Software Version lb lb lb in in in R410A 147.3 173.2 10.2 15.5 15.8 97 Plate Heat Exchanger 10 Water 54 44 36.9 / 38.7 351.9 16.7 0.0001 4" 120 625 95 118.8 / 117.1 10 0 150440 16.8 460-3-60 / 414-506 319 350 350 5 1 #4 - 500 kcmil 7269 7353 172 232.7 88.3 94.2 YW13.02a Certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI Directory at www.ahridirectory.org Auxiliary components included in total KW - Oil heaters, Chiller controls. Auxiliary power is already included in the compressor and fan power 56 JOHNSON CONTROLS MODEL: YLAA0156HE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88 1/4" - FRAME WIDTH 88 3/4" - OVERALL WIDTH 23 3/16" ORIGIN 81 5/8" C G Y Project Name : cg ylaa Location : Engineer : Contractor : For : 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3. CENTER OF GRAVITY FROM ORIGIN: X= 95.8"; Y= 51.2" . 2. WEIGHTS (LB): SHIPPING - 7,269; OPERATING - 7,352. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6' CONTROL PANEL TO WALL - 4' TOP - NO OBSTRUCTIONS ALLOWED DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THAN ONE ADJACENT WALL MAY BE HIGHER THAN THE UNIT. 3 5/16" 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. 94 3/8" - OVERALL HEIGHT 88 1/2" - FRAME HEIGHT jOHNSON CONTROLS X 7 11/16" 69" 58" UNIT3 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 230 1/4" - FRAME LENGTH 43" 42 1/2" 5/8" DIA MOUNTING HOLES (TYP) 82 7/8" 93 5/8" 1 3/8" 4" OUTLET 4" INLET 13/16" Date : 5/21/2013 15:16:58 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 3/8" A JOHNSON CONTROLS COMPANY 5 3/8" CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 32 3/8" 10" NOTES: MODEL: YLAAB0156SE AHRI CAPACITY 147.3 TONS YLAA 131 TO 175 57 Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Net Cooling Capacity Total Power Input EER IPLV NPLV Sound Power Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Min Fluid Flow Rate Max Fluid Flow Rate Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power YLAA-B0170SE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in USGPM USGPM °F °F ft cfm kW Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Unit Short Circuit Current Withstand Wire Lugs Per Phase Wire Range (Lug Size) A A A [kA] Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height Software Version lb lb lb in in in R410A 170.5 208.6 9.8 15.1 15.9 97 Plate Heat Exchanger 10 Water 54 44 37 / 37 407.4 22.1 0.0001 4" 120 625 95 121.3 / 121.3 10 0 150440 16.8 460-3-60 / 414-506 372 400 400 5 2 #4 - 500 kcmil 7624 7708 179 232.7 88.3 94.2 YW13.02a Certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI Directory at www.ahridirectory.org Auxiliary components included in total KW - Oil heaters, Chiller controls. Auxiliary power is already included in the compressor and fan power 58 JOHNSON CONTROLS MODEL: YLAA0170SE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88 1/4" - FRAME WIDTH 88 3/4" - OVERALL WIDTH 23 3/16" ORIGIN 81 5/8" C G Y Project Name : cg ylaa Location : Engineer : Contractor : For : 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3. CENTER OF GRAVITY FROM ORIGIN: X= 97.1"; Y= 52.2" . 2. WEIGHTS (LB): SHIPPING - 7,624; OPERATING - 7,707. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6' CONTROL PANEL TO WALL - 4' TOP - NO OBSTRUCTIONS ALLOWED DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THAN ONE ADJACENT WALL MAY BE HIGHER THAN THE UNIT. 3 5/16" 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. 94 3/8" - OVERALL HEIGHT 88 1/2" - FRAME HEIGHT jOHNSON CONTROLS X 7 11/16" 69" 58" UNIT4 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 230 1/4" - FRAME LENGTH 43" 42 1/2" 5/8" DIA MOUNTING HOLES (TYP) 82 7/8" 93 5/8" 1 3/8" 4" OUTLET 4" INLET 13/16" Date : 5/21/2013 15:17:18 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 3/8" A JOHNSON CONTROLS COMPANY 5 3/8" CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 32 3/8" 10" NOTES: MODEL: YLAAB0170SE AHRI CAPACITY 170.5 TONS YLAA 131 TO 175 59 Air Cooled Scroll Chiller Performance Specification Unit Type and Size ID Number of Compressors Compressor Type Number of Compressor Circuits Technical Data Refrigerant Type Net Cooling Capacity Total Power Input EER IPLV NPLV Sound Power Evaporator Evaporator Type Fluid Volume Fluid Type Entering Liquid Temperature Leaving Liquid Temperature EvaporatingTemperature Total Flow Rate Total Pressure Drop Fouling Factor Fluid Connection Diameter Min Fluid Flow Rate Max Fluid Flow Rate Condenser (Air Cooled) Ambient Air Temperature Condensing Temperature Number of Fans Altitude Total Air Flow Total Fan Power YLAA-B0175HE 6 Scroll - Hermetic 2 TR kW EER EER EER dB(A) USGAL °F °F °F USGPM ft H2O h.ft².F/Btu in USGPM USGPM °F °F ft cfm kW Electrical Data Nominal Voltage / Voltage Limits Min. Circuit Ampacity Max. Fuse / CB Rating Min. Fuse / CB Rating Unit Short Circuit Current Withstand Wire Lugs Per Phase Wire Range (Lug Size) A A A [kA] Weights and Dimensions Shipping Weight Operating Weight Refrigerant Charge Overall Length Overall Width Overall Height Software Version lb lb lb in in in R410A 176 211.1 10 15.1 16 97 Plate Heat Exchanger 14.3 Water 54 44 39.6 / 39.6 420 16.4 0.0001 4" 180 650 95 122 / 122 10 0 150440 16.8 460-3-60 / 414-506 372 400 400 5 2 #4 - 500 kcmil 7772 7891 187 232.7 88.3 94.2 YW13.02a Certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI Directory at www.ahridirectory.org Auxiliary components included in total KW - Oil heaters, Chiller controls. Auxiliary power is already included in the compressor and fan power 60 JOHNSON CONTROLS MODEL: YLAA0175HE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88 1/4" - FRAME WIDTH 88 3/4" - OVERALL WIDTH 23 3/16" ORIGIN 81 5/8" C G Y Project Name : cg ylaa Location : Engineer : Contractor : For : 4. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMODATIONS IN CHILLED WATER PIPING NEAR THE EVAPORATOR. 3. CENTER OF GRAVITY FROM ORIGIN: X= 97.4"; Y= 52" . 2. WEIGHTS (LB): SHIPPING - 7,771; OPERATING - 7,890. RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL - 6' REAR TO WALL - 6' CONTROL PANEL TO WALL - 4' TOP - NO OBSTRUCTIONS ALLOWED DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THAN ONE ADJACENT WALL MAY BE HIGHER THAN THE UNIT. 3 5/16" 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION. 94 3/8" - OVERALL HEIGHT 88 1/2" - FRAME HEIGHT jOHNSON CONTROLS X 7 11/16" 69" 58" UNIT5 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 230 1/4" - FRAME LENGTH 43" 42 1/2" 5/8" DIA MOUNTING HOLES (TYP) 82 7/8" 93 5/8" 1 3/8" 4" OUTLET 4" INLET 13/16" Date : 5/21/2013 15:17:39 Rev. Date : Form : Dwg. Lev. : Dwg. Scale : NTS 46 3/8" A JOHNSON CONTROLS COMPANY 5 3/8" CONTROL PANEL BOTTOM DETAIL POWER ENTRY 13" WIDE X 7" HIGH 32 3/8" 10" NOTES: MODEL: YLAAB0175HE AHRI CAPACITY 176 TONS YLAA 131 TO 175 61 62 JOHNSON CONTROLS YVAA 150 to 500 Tons Air Cooled Screw Chiller jOHNSON CONTROLS 63 YVAA RIGGING Lifting Unit Container lugs should be inserted into the holes provided in the bottom of the frame rail. Use spreader bars to avoid lifting chains hitting the chiller. Various methods of spreader bar arrangements may be used; keeping in mind the intent is to keep the unit stable and to keep the chains from hitting the chiller and causing damage. WARNING — Never lift the chiller using a forklift or by hooking the top rails. Use only the lifting holes provided. Lifting instructions are placed on a label on the chiller and on the shipping bag. 64 JOHNSON CONTROLS Delivery and Storage To ensure consistent quality and maximum reliability, all units are tested and inspected before leaving the factory. Units are shipped completely assembled and containing refrigerant under pressure. Units are shipped without export crating unless crating has been specified on the Sales Order. If the unit is to be put into storage, prior to installation, the following precautions should be observed. • The chiller must be “blocked” so that the base is not permitted to sag or bow. • Ensure that all openings, such as water connections, are securely capped. • Do not store where exposed to ambient air temperatures exceeding 43°C (110°F). • The condensers should be covered to protect the coils and fins from potential damage and corrosion, particularly where building work is in progress. • The unit should be stored in a location where there is minimal activity in order to limit the risk of accidental physical damage. • To prevent inadvertent operation of the pressure relief devices the unit must not be steam cleaned. • It is recommended that the unit is periodically inspected during storage. Inspection Remove any transit packing and inspect the unit to ensure that all components have been delivered and that no damage has occurred during transit. If any damage is evident, it should be noted on the carrier’s freight bill and a claim entered in accordance with the instructions given on the advice note. Major damage must be reported immediately to your local Johnson Controls representative. Moving the Chiller Prior to moving the unit, ensure that the installation site is suitable for installing the unit and is easily capable of supporting the weight of the unit and all associated services. The units are designed to be lifted using shackles or safety hooks. A spreader bar or frame should be used in order to prevent damage to the unit from the lifting chains. (Refer to Figure 4 on Page 20 of the Operations and Maintenance Guide [Form 201.28-NM1.1 (812)] for hooks.) Units are provided with lifting eyes in the sites of the base frame, which can be attached directly using container lugs, shackles or safety hooks (Refer to Figure 4 on Page 20 of the Operations and Maintenance Guide [Form 201.28-NM1.1 (812)] for proper lifting illustration). WARNING — The unit must only be lifted by the base frame at the points provided. Never move the unit on rollers, or lift the unit using a forklift truck. Care should be taken to avoid damaging the condenser cooling fins when moving the unit. Lifting Weights For details of weights and weight distribution, refer to the data shipped in the chiller information packet and unit nameplate. jOHNSON CONTROLS 65 AIR COOLED SCREW CHILLER YVAA - 150 to 500 TONS (R-134A) BENEFITS •Continuous function, microprocessor controlled Variable Speed Drive (VSD) for valve less, smooth capacity control to 10% of chiller capacity • Chiller speed matched to system requirements at off-peak conditions resulting in lower energy usage • Use of VSD reduces compressor moving parts by 50% • Soft motor start with no electrical inrush reduces components stress, heat buildup • Operating efficiencies at off-design conditions results in IPLVs as high as 19.8 EER •Standard full load power factor of 95%, maintained throughout operating range resulting in improved energy savings • Superior acoustic operation at off-design conditions • HFC-R134a standard for long term availability and zero ODP • Wide range of options to fit any design requirement • Competitors MCA is an average of 10% higher than YORK’s • Lower MCA allows for smaller wiring and smaller circuit breakers therefore lower costs • Allows for replacing chiller and increasing tonnage without replacing electrical components • Industry’s only 18-month air cooled warranty that covers all parts. UPGRADE OPTIONS • Remote Cooler • Factory mounted non-fused disconnect switch or circuit breaker • Epoxy Post Coated, Pre Coated or Post Coated for tube and fin •Seamless internally enhanced copper fin & tube coils arranged in staggered rows; mechanically bonded to full eight aluminum fins • Evaporator Options: • 1-1/2" Insulation (double thickness) • Raised Face Flange Accessory for cooler nozzles • Flow Switch Accessory: Vapor proof, SPDT, NEMA 3R switch, 150psig • Suction service isolation valve per circuit (discharge valve standard) • Unit Enclosure Options: •Wire Panels (full unit): coated, heavy gauge welded wire mesh mounted on exterior of unit to prevent unauthorized access to refrigerant components •Louvered Panels (condenser coils only): Painted to match unit; louvered panels mounted over exterior condenser coils faces to visually screen unit, protects coils •Louvered Panels (full unit): Painted to match unit; to protect condenser coils, visually screen internal components and prevent unauthorized access •Louvered (condensers)/Wire Panels (mechanicals): Louvered steel panels on external condenser coil faces, heavy-gauge welded-wire mesh around base to prevent unauthorized access • Sound Attenuation: •SilentNightTM controls to force lower sound levels on demand or per user schedule • Ultra quiet fans, compressor sound blankets and/or acoustical enclosures • Vibration Isolation: Neoprene, 1" spring isolators or 2" spring isolators 66 JOHNSON CONTROLS AIR COOLED SCREW CHILLER YVAA - 150 to 500 TONS PACKAGE DESCRIPTION: Evaporator: • Self contained, designed for outdoor installation • Baked on powder paint • Heavy gauge, formed galvanized steel base • Factory mounted control transformer • ARI-Standard 550/590-11 Rated & Certified •All exposed wiring routed through liquid-tight, non-metallic conduit •High efficiency Hybrid falling film cooler; refrigerant in shell and water in tubes • Removable heads to access copper tubes • Air vent and water drain connections • Heater protection to -20 deg. F ambient • Insulated with ¾" closed cell foam •Design working pressure 150 PSIG water side and 235 PSIG on refrigerant side Compressors: • Reliable VSD driven semi-hermetic twin screw •High efficiency, accessible hermetic motor with redundant overload protection • Temperature actuated body cartridge heater • Acoustically tuned discharge gas muffler • Design pressure of compressor 450 PSIG Condenser: •Low noise, full airflow cross section fans for maximum efficiency; statically & dynamically balanced for low vibration operation; positioned in extended orifices for low sound •High efficiency, direct drive, 3-phase totally enclosed fan motors with double sealed, permanently lubricated ball bearings •Condenser coils are made of a single material to avoid galvanic corrosion due to dissimilar metals. Coils and headers are brazed as one piece • Design Working Pressure 450 PSIG Electrical: •Competitors MCA is an average of 10% higher than YORK’s •Lower MCA allows for smaller wiring and smaller circuit breakers therefore lower costs •Allows for replacing chiller and increasing tonnage without replacing electrical components jOHNSON CONTROLS Refrigerant circuit: • Independent circuits per compressor •Computer controlled bending of refrigerant pipe reduces over 60% of pipe brazed joints •Liquid line components include: manual shutoff valve with charging port, removable core filterdrier, solenoid valve, sight glass with moisture indicator, electronic expansion valves •Discharge line proided with manual compressor shutoff service valve •External Oil separators with no moving parts, 450 PSIG design working pressure Controls: •All controls housed in a NEMA 3R cabinet with gasket sealed, hinged & latched door •VSD section includes dedicated inverter for each compressor •Control display accessible without opening main cabinet doors • LCD, 80-character display with backlight • Color coded, sealed keypad •Standard controls permit operation from 0 to 125 deg F ambient temperature 67 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0153BAF46 150.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0153BAF46BA VSXX XTAXLXXXX60 44XOXXX S189W 1SXXA2B MXF PXXXX XXXX BXSX 5 10 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 359.6 5.6 Water 0.00010 58.0 25 30 35 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) Max. Flow Rate (gpm) 250.0 950.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 Circuit 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 109 4/3.3 1 109 4/3.3 Compressor RLA Fan QTY/FLA (each) 50 3 10.1 / 3.0 15.1 / 4.4 10 % 11518 11979 4 Single Point Min. Circuit Ampacity 275 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 350 350 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 350 30kA 2 #2 - 600 KCM 0.95 2.0 VSD Operating Condition Electrical Data Compressor kW 162.6 Total Fan kW 14.8 Total kW 177.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 150.0 112.5 75.0 37.5 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.1 / 3.0 13.3 / 3.9 16.3 / 4.8 17.6 / 5.2 Compressor kW 162.6 86.2 43.0 18.2 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0153BAF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 95.0 95.0 94.0 91.0 125 95.0 95.0 94.0 91.0 250 96.0 96.0 95.0 92.0 500 98.0 95.0 94.0 91.0 1K 95.0 92.0 91.0 88.0 2K 87.0 86.0 85.0 82.0 4K 83.0 82.0 81.0 78.0 8K 78.0 78.0 77.0 73.0 LWA 99.0 97.0 96.0 92.0 2K 60.0 59.0 58.0 55.0 4K 56.0 55.0 54.0 51.0 8K 51.0 51.0 50.0 46.0 dBA 72.0 70.0 69.0 65.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0153BAF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 68.0 68.0 69.0 71.0 75.0 80.0 68.0 68.0 69.0 68.0 50.0 65.0 67.0 67.0 68.0 67.0 25.0 55.0 64.0 64.0 65.0 64.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 68.0 65.0 64.0 61.0 Performance at AHRI Conditions YVAA0153BAF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 359.6 Pressure Drop (ft.) 5.6 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 58.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.1 / 3.0 EER IPLV/COP IPLV 15.1 / 4.4 Capacity (Tons) 150.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 68 JOHNSON CONTROLS 15 1/8" AIR-COOLED SCREW CHILLER MODEL: YVAA0153BAF46 NOT FOR CONSTRUCTION PRODUCT DRAWING POWER: SINGLE POINT WITH TERMINAL BLOCK 88 3/16" 44 1/8" Project Name : stp Location : Engineer : Contractor : For : 26 9/16" 6" (WATER INLET) C G Y X 780 644 2,116 2,147 75 15/16" (4) RIGGING HOLES EACH SIDE 3 X 2 48 11/16" 6 15/16" 56 1/8" A 41 1/4" 62 9/16" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 203 1/4" 71 1/4" 2,116 2,147 3/4" MOUNTING HOLES (TYP) 1,052 978 VSD / POWER PANEL jOHNSON CONTROLS 6" (WATER OUTLET) NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 11,518, OPERATING - 11,980. 3. CENTER OF GRAVITY FROM ORIGIN: X= 101.8", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. 14 1/8" 18 1/4" 47 5/16" 10 3/8" A 60" 94 1/2" 4" VIEW B-B 12" B VIEW A-A 2 15/16" CONTROL ENTRY 3" WIDE X 11 1/2" HIGH POWER ENTRY IS ON BOTTOM OF PANEL 1 1/2" POWER ENTRY 10" WIDE X 13" HIGH B Date : 12/6/2012 11:43:34 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 1 3/8" (TYP) MODEL: YVAA0153BAF46 AHRI CAPACITY 150.0 TONS YVAA 150 TO 200 69 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0183ABF46 175.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0183ABF46BAVSXXXTAXLXXXX6044XOXXXS192W1SXXA2BMXFPXXXXXXXXBXSX 5 10 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 419.5 11.4 Water 0.00010 48.0 25 30 35 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) Max. Flow Rate (gpm) 200.0 750.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 Circuit 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 111 4/3.3 1 139 6/3.3 Compressor RLA Fan QTY/FLA (each) 50 3 10.4 / 3.0 15.4 / 4.5 10 % 12019 12460 4 Single Point Min. Circuit Ampacity 322 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 450 450 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 450 30kA 2 #2 - 600 KCM 0.95 2.0 VSD Operating Condition Electrical Data Compressor kW 184.4 Total Fan kW 17.9 Total kW 202.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 175.0 131.3 87.5 43.7 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.4 / 3.0 13.5 / 4.0 16.5 / 4.8 17.9 / 5.2 Compressor kW 184.4 97.8 49.4 22.0 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0183ABF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 96.0 96.0 94.0 91.0 125 96.0 96.0 95.0 91.0 250 97.0 97.0 95.0 92.0 500 98.0 96.0 95.0 91.0 1K 94.0 94.0 91.0 88.0 2K 88.0 87.0 86.0 82.0 4K 84.0 83.0 82.0 78.0 8K 80.0 79.0 78.0 73.0 LWA 99.0 98.0 96.0 93.0 2K 61.0 60.0 59.0 55.0 4K 57.0 56.0 55.0 51.0 8K 53.0 52.0 51.0 46.0 dBA 72.0 71.0 69.0 66.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0183ABF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 69.0 69.0 70.0 71.0 75.0 80.0 69.0 69.0 70.0 69.0 50.0 65.0 67.0 68.0 68.0 68.0 25.0 55.0 64.0 64.0 65.0 64.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 67.0 67.0 64.0 61.0 Performance at AHRI Conditions YVAA0183ABF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 419.5 Pressure Drop (ft.) 11.4 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 48.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.4 / 3.0 EER IPLV/COP IPLV 15.4 / 4.5 Capacity (Tons) 175.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 70 JOHNSON CONTROLS 14 1/8" AIR-COOLED SCREW CHILLER MODEL: YVAA0183ABF46 NOT FOR CONSTRUCTION PRODUCT DRAWING POWER: SINGLE POINT WITH TERMINAL BLOCK 88 3/16" 44 1/8" Project Name : stp Location : Engineer : Contractor : For : 25 9/16" 6" (WATER INLET) C G Y X 38 3/4" 47 5/8" 1,654 1,659 247" 82 13/16" (4) RIGGING HOLES EACH SIDE 3 X 2 1,084 1,088 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 77 1/4" 1,084 1,729 46 3/4" 1,088 17 11/16" 1,660 3/4" MOUNTING HOLES (TYP) 42 1/16" 66 1/8" A 711 704 VSD / POWER PANEL jOHNSON CONTROLS 6" (WATER OUTLET) NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 12,019, OPERATING - 12,460. 3. CENTER OF GRAVITY FROM ORIGIN: X= 128.4", Y= 44.2". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. 14 1/8" 94 1/2" 4" VIEW B-B 12" B VIEW A-A 2 15/16" CONTROL ENTRY 3" WIDE X 11 1/2" HIGH POWER ENTRY IS ON BOTTOM OF PANEL 1 1/2" POWER ENTRY 10" WIDE X 13" HIGH B Date : 12/6/2012 11:51:6 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 18 1/4" 47 5/16" 10 3/8" A 60" 1 1/4" (TYP) MODEL: YVAA0183ABF46 AHRI CAPACITY 175.0 TONS YVAA 150 TO 200 71 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0233BEF46 200.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0233BEF46BAVSXXXTAXLXXXX6044XOXXXS176W1SXXA2BMXFPXXXXXXXXBXSX 5 10 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 479.4 9.2 Water 0.00010 58.0 25 30 35 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) Max. Flow Rate (gpm) 250.0 950.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 Circuit 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 135 5/3.3 1 158 7/3.3 Compressor RLA Fan QTY/FLA (each) 50 3 10.5 / 3.1 15.2 / 4.5 10 % 13288 13750 4 Single Point Min. Circuit Ampacity 375 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 500 500 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 500 30kA 2 #2 - 600 KCM 0.95 2.0 VSD Operating Condition Electrical Data Compressor kW 208.4 Total Fan kW 21.1 Total kW 229.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 200.0 150.0 100.0 50.0 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.5 / 3.1 13.5 / 4.0 16.2 / 4.7 17.3 / 5.1 Compressor kW 208.4 111.2 56.5 23.9 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0213ADF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 97.0 97.0 96.0 93.0 125 97.0 97.0 96.0 93.0 250 98.0 98.0 97.0 94.0 500 97.0 97.0 96.0 94.0 1K 94.0 93.0 93.0 90.0 2K 88.0 88.0 87.0 84.0 4K 84.0 84.0 83.0 80.0 8K 80.0 80.0 78.0 76.0 LWA 99.0 99.0 97.0 95.0 2K 61.0 61.0 60.0 57.0 4K 57.0 57.0 56.0 53.0 8K 53.0 53.0 51.0 49.0 dBA 72.0 72.0 70.0 68.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0213ADF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 70.0 70.0 71.0 70.0 75.0 80.0 70.0 70.0 71.0 70.0 50.0 65.0 69.0 69.0 70.0 69.0 25.0 55.0 66.0 66.0 67.0 67.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 67.0 66.0 66.0 63.0 Performance at AHRI Conditions YVAA0213ADF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 479.4 Pressure Drop (ft.) 9.2 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 58.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.5 / 3.1 EER IPLV/COP IPLV 15.2 / 4.5 Capacity (Tons) 200.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 72 JOHNSON CONTROLS 15 1/8" AIR-COOLED SCREW CHILLER MODEL: YVAA0233BEF46 NOT FOR CONSTRUCTION PRODUCT DRAWING POWER: SINGLE POINT WITH TERMINAL BLOCK 88 3/16" 44 1/8" Project Name : stp Location : Engineer : Contractor : For : 26 9/16" 6" (WATER INLET) C G Y X 670 659 57 5/8" 72 5/16" 73 5/16" 670 659 38 3/4" 933 1,430 291 3/16" 76 13/16" 41 5/8" 947 1,423 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 77 5/8" (5) RIGGING HOLES EACH SIDE 3 X 2 51 3/4" 2,247 2,230 3/4" MOUNTING HOLES (TYP) 42 1/16" 66 1/8" A 947 933 VSD / POWER PANEL jOHNSON CONTROLS 6" (WATER OUTLET) NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 13,288, OPERATING - 13,750. 3. CENTER OF GRAVITY FROM ORIGIN: X= 134.7", Y= 44.1". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. 14 1/8" 94 1/2" 4" VIEW B-B 12" B VIEW A-A 2 15/16" CONTROL ENTRY 3" WIDE X 11 1/2" HIGH POWER ENTRY IS ON BOTTOM OF PANEL 1 1/2" POWER ENTRY 10" WIDE X 13" HIGH B Date : 12/6/2012 12:52:26 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 18 1/4" 47 5/16" 10 3/8" A 60" 1 1/4" (TYP) MODEL: YVAA0233BEF46 AHRI CAPACITY 200.0 TONS YVAA 150 TO 200 73 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0273DGF46 250.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0273DGF46BAVSXXXTAXLXXXX6044XOXXXS188W1SXXA2BMXFXXXXXXXXXBXSX 5 10 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 598.3 15.2 Water 0.00010 82.0 25 30 35 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 300.0 Max. Flow Rate (gpm) 1150.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) Circuit 55 60 65 Performance Data EER / COP NPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 175 7/3.3 1 175 7/3.3 Compressor RLA Fan QTY/FLA (each) 95.0 0 0.0 50 3 10.8 / 3.2 16.0 / 4.7 10 % 16275 17103 4 Single Point Min. Circuit Ampacity 444 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 600 600 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 600 30kA 2 #2 - 600 KCM 0.95 2.0 VSD Operating Condition Electrical Data Compressor kW 253.5 Total Fan kW 24.2 Total kW 277.7 * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 250.0 187.5 125.0 62.5 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.8 / 3.2 14.0 / 4.1 17.2 / 5.0 18.9 / 5.5 Compressor kW 253.5 135.2 68.3 29.0 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0273DGF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 97.0 97.0 96.0 93.0 125 97.0 97.0 96.0 93.0 250 98.0 98.0 97.0 94.0 500 97.0 97.0 96.0 94.0 1K 94.0 93.0 93.0 90.0 2K 88.0 88.0 87.0 84.0 4K 84.0 84.0 83.0 80.0 8K 80.0 80.0 78.0 76.0 LWA 99.0 99.0 97.0 95.0 2K 63.0 62.0 61.0 58.0 4K 59.0 58.0 57.0 54.0 8K 54.0 53.0 52.0 49.0 dBA 74.0 72.0 71.0 68.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0213ADF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 71.0 71.0 72.0 73.0 75.0 80.0 71.0 71.0 72.0 71.0 50.0 65.0 69.0 69.0 70.0 70.0 25.0 55.0 66.0 67.0 67.0 67.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 70.0 67.0 66.0 63.0 Performance at AHRI Conditions YVAA0273DGF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 599.8 Pressure Drop (ft.) 15.3 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 82.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.8 / 3.2 EER IPLV/COP IPLV 16.0 / 4.7 Capacity (Tons) 249.9 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 74 JOHNSON CONTROLS 44 1/8" 15 5/16" AIR-COOLED SCREW CHILLER MODEL: YVAA0273DGF46 NOT FOR CONSTRUCTION PRODUCT DRAWING POWER: SINGLE POINT WITH TERMINAL BLOCK 88 3/16" 26 3/4" X 59 1/8" Project Name : adsfasdfa Location : Engineer : Contractor : For : 6" (WATER INLET) C G Y 1,518 1,389 1,946 2,135 83 1/4" (6) RIGGING HOLES EACH SIDE 3 X 2 100 5/16" 42 7/8" 60 3/16" 335 3/16" 79 13/16" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 40 3/16" 3,036 2,778 48 5/16" 1,372 1,539 3/4" MOUNTING HOLES (TYP) 60 1/4" 70 5/8" A 710 14 1/8" 12 3/8" 47 1/2" 10 3/8" A 60" 4" VIEW B-B POWER ENTRY 10" WIDE X 13" HIGH 12" B VIEW A-A 2 15/16" CONTROL ENTRY 3" WIDE X 11 1/2" HIGH POWER ENTRY IS ON BOTTOM OF PANEL 1 1/2" 94 11/16" 1 5/16" (TYP) B Date : 3/6/2013 8:56:2 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 681 VSD / POWER PANEL jOHNSON CONTROLS 6" (WATER OUTLET) NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 16,275, OPERATING - 17,103. 3. CENTER OF GRAVITY FROM ORIGIN: X= 168.3", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. MODEL: YVAA0273DGF46 AHRI CAPACITY 250.0 TONS YVAA 201 TO 500 75 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0343EKF46 300.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0343EKF46BA VSXX XTAXLXXXX60 44XOXXX S179W 1SXXA2B MXF PXXXX XXXX BXSX 5 10 15 20 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 719.1 11.8 Water 0.00010 113.0 25 30 35 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 400.0 Max. Flow Rate (gpm) 1500.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) Circuit 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 209 9/3.3 1 209 9/3.3 Compressor RLA Fan QTY/FLA (each) 95.0 0 0.0 50 3 10.9 / 3.2 15.5 / 4.5 10 % 19315 20175 4 Single Point Min. Circuit Ampacity 533 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 700 700 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 700 30kA 3 #2 - 600 KCM 0.95 2.0 VSD Operating Condition Electrical Data Compressor kW 300.3 Total Fan kW 30.5 Total kW 330.8 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 300.0 225.0 150.0 75.0 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.9 / 3.2 13.9 / 4.1 16.5 / 4.8 17.8 / 5.2 Compressor kW 300.3 162.5 85.1 38.1 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0343EKF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 99.0 99.0 97.0 94.0 125 99.0 99.0 97.0 94.0 250 100.0 100.0 98.0 95.0 500 99.0 100.0 98.0 94.0 1K 98.0 98.0 95.0 92.0 2K 92.0 91.0 89.0 87.0 4K 87.0 88.0 85.0 83.0 8K 83.0 84.0 81.0 79.0 LWA 102.0 102.0 100.0 96.0 2K 65.0 64.0 62.0 60.0 4K 60.0 61.0 58.0 56.0 8K 56.0 57.0 54.0 52.0 dBA 75.0 75.0 73.0 69.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0343EKF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 72.0 72.0 73.0 72.0 75.0 80.0 72.0 72.0 73.0 73.0 50.0 65.0 70.0 70.0 71.0 71.0 25.0 55.0 67.0 67.0 68.0 67.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 71.0 71.0 68.0 65.0 Performance at AHRI Conditions YVAA0343EKF46 Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 719.1 11.8 Water 0.00010 113.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.9 / 3.2 EER IPLV/COP IPLV 15.5 / 4.5 Capacity (Tons) 300.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 76 JOHNSON CONTROLS 44 1/8" 15 1/2" AIR-COOLED SCREW CHILLER MODEL: YVAA0343EKF46 NOT FOR CONSTRUCTION PRODUCT DRAWING POWER: SINGLE POINT WITH TERMINAL BLOCK 88 3/16" 29 1/2" Project Name : stp Location : Engineer : Contractor : For : 8" (WATER INLET) X 1000" (7) RIGGING HOLES EACH SIDE 3 X 2 C G Y 423 1/8" 40 3/16" 79 13/16" 48 5/16" 1,966 1,995 3/4" MOUNTING HOLES (TYP) 60 3/16" 2,259 2,260 Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 61 3/4" 2,259 97 1/2" 1,951 863 84 7/16" 2,260 1,910 863 132 3/16" 790 14 1/8" 12 3/8" 47 1/2" 10 1/4" A 60" 4" VIEW B-B POWER ENTRY 10" WIDE X 13" HIGH 12" B VIEW A-A 2 15/16" CONTROL ENTRY 3" WIDE X 11 1/2" HIGH POWER ENTRY IS ON BOTTOM OF PANEL 1 1/2" 94 11/16" 1 3/8" (TYP) B Date : 12/6/2012 13:34:33 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 60 1/4" 70 5/8" A 801 VSD / POWER PANEL jOHNSON CONTROLS 8" (WATER OUTLET) NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 19,316, OPERATING - 20,175. 3. CENTER OF GRAVITY FROM ORIGIN: X= 187.5", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. MODEL: YVAA0343EKF46 AHRI CAPACITY 300.0 TONS YVAA 201 TO 500 77 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0373FJF46 350.0 460/3/60 R134a Pin: BASE MODEL POWER YVAA0373FJF46BA VSXX XTAXLXXXX60 44XOXXX S196W 1SXXA2B MXF XXXXX XXXX BXSX 5 10 CONTROLS 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 837.7 11.2 Water 0.00010 96.0 PIPING 25 30 COMP 35 EVAPORATOR 40 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 460.0 Max. Flow Rate (gpm) 1540.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) Circuit CABINET 50 MISC 55 WARR 60 65 Performance Data EER / COP NPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 178 7/3.3 1 327 7/3.3 Compressor RLA Fan QTY/FLA (each) 95.0 0 0.0 COND 3 10.4 / 3.0 15.0 / 4.4 10 % 22346 23405 4 Single Point Min. Circuit Ampacity 658 Recommended Fuse/CB Rating Max. Inverse Time CB Rating 800 800 Max. Dual Element Fuse Size (Amps) Unit Short Circuit Withstand (STD) Wire Lugs Per Phase* Wire Range (Lug Size) Unit Power Factor Control KVA Starter Type Notes: 800 30kA 2 #2 - 600 KCM 0.95 3.0 VSD Operating Condition Electrical Data Compressor kW 372.6 Total Fan kW 31.8 Total kW 404.4 * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 350.0 262.5 175.0 87.5 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.4 / 3.0 13.3 / 3.9 16.1 / 4.7 17.4 / 5.1 Compressor kW 372.6 203.4 105.5 44.4 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0373FJF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 99.0 99.0 98.0 96.0 125 99.0 100.0 98.0 96.0 250 100.0 100.0 99.0 97.0 500 103.0 100.0 98.0 97.0 1K 100.0 97.0 95.0 92.0 2K 97.0 91.0 89.0 87.0 4K 96.0 88.0 86.0 84.0 8K 85.0 83.0 83.0 81.0 LWA 105.0 102.0 100.0 98.0 2K 70.0 64.0 62.0 60.0 4K 69.0 61.0 59.0 57.0 8K 58.0 56.0 56.0 54.0 dBA 78.0 75.0 73.0 71.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0373FJF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 72.0 72.0 73.0 76.0 75.0 80.0 72.0 73.0 73.0 73.0 50.0 65.0 71.0 71.0 72.0 71.0 25.0 55.0 69.0 69.0 70.0 70.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 73.0 70.0 68.0 65.0 Performance at AHRI Conditions YVAA0373FJF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 839.7 Pressure Drop (ft.) 11.3 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 96.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.4 / 3.0 EER IPLV/COP IPLV 15.0 / 4.4 Capacity (Tons) 349.9 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 78 JOHNSON CONTROLS jOHNSON CONTROLS 88 5/16" 44 1/8" 15 13/16" 28 13/16" 94 11/16" 8" WATER INLET AIR-COOLED SCREW CHILLER MODEL: YVAA0373FJF46 NOT FOR CONSTRUCTION PRODUCT DRAWING 8" WATER OUTLET NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 22,346, OPERATING - 23,405. 3. CENTER OF GRAVITY FROM ORIGIN: X= 200.3", Y= 46.6". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. Project Name : adsfasdfa Location : Engineer : Contractor : For : (6) RIGGING HOLES EACH SIDE 3 X 2 133 11/16" 142 11/16" 467 1/8" 56 5/8" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 63 7/8" 78 11/16" 60 5/8" 108 1/2" 63 7/8" 10 5/16" 12 5/16" A 42 1/8" B END VIEW SECTION 12" 2 15/16" A-A B-B POWER ENTRY 10" WIDE X 13" HIGH SECTION CONTROL ENTRY 3" WIDE X 11 1/2" HIGH 2 1/2" 2 1/2" B Date : 3/5/2013 14:21:26 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 60 5/16" 70 11/16" A 3/4" MOUNTING HOLES (TYP) MODEL: YVAA0373EKF46 AHRI CAPACITY 350.0 TONS YVAA 201 TO 500 79 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0443FMF46 400.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0443FMF46BA VDXX XTAXLXXXX60 44XOXXX S172W 1SXXA2B MXF PXXXX XXXX BXSX 5 10 15 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 20 54.0 44.0 958.8 14.3 Water 0.00010 96.0 Circuit 25 30 35 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 460.0 Max. Flow Rate (gpm) 1540.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 50 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 287 12/3.3 1 287 12/3.3 Compressor RLA Fan QTY/FLA (each) 40 3 10.6 / 3.1 14.8 / 4.3 10 % 25942 27001 4 Single Point Min. Circuit Ampacity 398 398 Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 600 600 600 600 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Unit Power Factor Control KVA Starter Type 600 600 600 #2 - 600 KCM 0.95 3.0 VSD 600 600 600 #2 - 600 KCM 0.95 Notes: Operating Condition Electrical Data Compressor kW 414.4 Total Fan kW 38.0 Total kW 452.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 400.0 300.0 200.0 100.0 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.6 / 3.1 13.2 / 3.9 15.8 / 4.6 17.3 / 5.1 Compressor kW 414.4 231.7 120.9 53.3 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0443FMF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 100.0 100.0 99.0 96.0 125 100.0 100.0 99.0 96.0 250 101.0 101.0 100.0 97.0 500 102.0 102.0 100.0 98.0 1K 99.0 100.0 96.0 93.0 2K 95.0 92.0 90.0 87.0 4K 93.0 90.0 87.0 84.0 8K 88.0 85.0 85.0 82.0 LWA 104.0 104.0 101.0 98.0 2K 68.0 65.0 63.0 60.0 4K 66.0 63.0 60.0 57.0 8K 61.0 58.0 58.0 55.0 dBA 77.0 77.0 74.0 71.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0443FMF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 73.0 73.0 74.0 75.0 75.0 80.0 73.0 73.0 74.0 75.0 50.0 65.0 72.0 72.0 73.0 73.0 25.0 55.0 69.0 69.0 70.0 71.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 72.0 73.0 69.0 66.0 Performance at AHRI Conditions YVAA0443FMF46 Evaporator Data EWT (°F) 54.0 LWT (°F) 44.0 Flow Rate (gpm) 958.8 Pressure Drop (ft.) 14.3 Fluid Water Fouling Factor 0.00010 Water Volume (gal) 96.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.6 / 3.1 EER IPLV/COP IPLV 14.8 / 4.3 Capacity (Tons) 400.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 80 JOHNSON CONTROLS jOHNSON CONTROLS 88" 44 1/8" 16" 29" 95" 8" WATER INLET AIR-COOLED SCREW CHILLER MODEL: YVAA0443FMF46 NOT FOR CONSTRUCTION PRODUCT DRAWING 8" WATER OUTLET NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 25,942, OPERATING - 27,001. 3. CENTER OF GRAVITY FROM ORIGIN: X= 213.7", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. 42" 56" Project Name : stp Location : Engineer : Contractor : For : 67" 88" 56" 143" 146" (8) RIGGING HOLES EACH SIDE 3 X 2 287" 52" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 555" 79" 57" 51" 109" 60" 71" 12" 10" A SECTION 42" B 12" 3" END VIEW SECTION A-A B-B POWER ENTRY 10" WIDE X 13" HIGH CONTROL ENTRY 3" WIDE X 11 1/2" HIGH 2 1/2" 2 1/2" B Date : 12/6/2012 13:47:41 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 73" A 3/4" MOUNTING HOLES (TYP) MODEL: YVAA0443FMF46 AHRI CAPACITY 400.0 TONS YVAA 201 TO 500 81 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0523HMF46 450.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0523HMF46BA VDXX XTAXLXXXX60 44XOXXX S183W 1SXXA2B MXF PXXXX XXXX BXSX 5 10 15 20 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 1078.7 14.8 Water 0.00010 147.0 Circuit 25 30 35 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 550.0 Max. Flow Rate (gpm) 1880.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 50 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 312 13/3.3 1 312 13/3.3 Compressor RLA Fan QTY/FLA (each) 40 3 10.9 / 3.2 15.4 / 4.5 10 % 28427 29784 4 Single Point Min. Circuit Ampacity 423 423 Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 700 700 700 700 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Unit Power Factor Control KVA Starter Type 700 700 700 #2 - 600 KCM 0.95 3.0 VSD 700 700 700 #2 - 600 KCM 0.95 Notes: Operating Condition Electrical Data Compressor kW 452.4 Total Fan kW 41.1 Total kW 493.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 450.0 337.5 225.0 112.5 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.9 / 3.2 13.7 / 4.0 16.4 / 4.8 18.2 / 5.3 Compressor kW 452.4 251.2 131.9 58.2 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0523HMF46 ( Equipped with Low Sound Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 101.0 100.0 99.0 96.0 125 101.0 101.0 99.0 96.0 250 102.0 102.0 100.0 97.0 500 102.0 103.0 100.0 97.0 1K 101.0 100.0 96.0 93.0 2K 96.0 93.0 91.0 87.0 4K 92.0 92.0 87.0 84.0 8K 87.0 86.0 85.0 81.0 LWA 104.0 104.0 101.0 98.0 2K 69.0 66.0 64.0 60.0 4K 65.0 65.0 60.0 57.0 8K 60.0 59.0 58.0 54.0 dBA 77.0 77.0 74.0 71.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0523HMF46 ( Equipped with Low Sound Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 74.0 74.0 75.0 75.0 75.0 80.0 73.0 74.0 75.0 76.0 50.0 65.0 72.0 72.0 73.0 73.0 25.0 55.0 69.0 69.0 70.0 70.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 74.0 73.0 69.0 66.0 Performance at AHRI Conditions YVAA0523HMF46 Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 1078.6 14.8 Water 0.00010 147.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.9 / 3.2 EER IPLV/COP IPLV 15.4 / 4.5 Capacity (Tons) 450.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 82 JOHNSON CONTROLS jOHNSON CONTROLS 88" 44 1/8" 16" 30" 95" 8" WATER INLET AIR-COOLED SCREW CHILLER MODEL: YVAA0523HMF46 NOT FOR CONSTRUCTION PRODUCT DRAWING 8" WATER OUTLET NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 28,427, OPERATING - 29,784. 3. CENTER OF GRAVITY FROM ORIGIN: X= 222.4", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. Project Name : stp Location : Engineer : Contractor : For : 79" 132" 57" 59" 78" 309" 146" 599" 52" 79" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: (8) RIGGHING HOLES EACH SIDE 3 X 2 143" 57" 51" 109" 60" 71" 12" 10" A B 42" SECTION END END VIEW VIEW SECTION 12" 3" B-B A-A POWER ENTRY 10" WIDE X 13" HIGH CONTROL ENTRY 3" WIDE X 11 1/2" HIGH 2 1/2" 2 1/2" B Date : 12/6/2012 13:57:16 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS A JOHNSON CONTROLS COMPANY YVAA can be tailored and tuned to your needs. Please contact your JCI Representative for further capacities and efficiencies. 73" A 3/4" MOUNTING HOLES (TYP) MODEL: YVAA0523HMF46 AHRI CAPACITY 450.0 TONS YVAA 201 TO 500 83 Air Cooled Screw Chiller Performance Specification Unit Tag Qty. Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant 1 YVAA0523HMG46 500.0 460/3/60 R134a Pin: BASE MODEL POWER CONTROLS PIPING COMP EVAPORATOR COND CABINET MISC WARR YVAA0523HMG46BA VDXX XTAXLXXXX60 44XOXXX S200W 1SXXA3B MXG XXXXX XXXX BXSX 5 10 15 20 Evaporator Data EWT (°F) LWT (°F) Design Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 1199.9 51.4 Water 0.00010 147.0 Circuit 25 30 35 45 Evaporator Data (Cont.) Min. Flow Rate (gpm) 400.0 Max. Flow Rate (gpm) 1400.0 Condenser Data Ambient Temp. Design (°F) Altitude (ft.) Ambient Temp. Min (°F) 95.0 0 0.0 50 55 60 65 Performance Data EER / COP IPLV Minimum Unit Capacity Physical Data Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 341 13/5.1 1 341 13/5.1 Compressor RLA Fan QTY/FLA (each) 40 3 10.5 / 3.1 14.4 / 4.2 10 % 29365 30722 4 Single Point Min. Circuit Ampacity 478 478 Min. Non-Fused Disconnect (Amps) Min. Dual Element Fuse Size (Amps) 800 800 800 800 Max. Dual Element Fuse Size (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Unit Power Factor Control KVA Starter Type 800 800 800 #2 - 600 KCM 0.95 3.0 VSD 800 800 800 #2 - 600 KCM 0.95 Notes: Operating Condition Electrical Data Compressor kW 495.3 Total Fan kW 74.7 Total kW 570.0 * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 Part Load Rating Data Capacity (Tons) 500.0 375.0 250.0 125.0 Ambient (°F) 95.0 80.0 65.0 55.0 Unit Efficiency 10.5 / 3.1 12.8 / 3.8 15.5 / 4.5 16.2 / 4.7 Compressor kW 495.3 272.8 151.9 63.4 SOUND POWER LEVELS (In Accordance with AHRI 370) – Octave Band Center Frequency, Hz YVAA0523HMG46 ( Equipped with High Airflow Fans ) Load % 100.0 75.0 50.0 25.0 Ambient (°F) 95.0 80.0 65.0 55.0 63 103.0 103.0 101.0 99.0 125 117.0 117.0 115.0 113.0 250 116.0 116.0 114.0 112.0 500 110.0 110.0 107.0 105.0 1K 107.0 106.0 103.0 101.0 2K 103.0 102.0 99.0 97.0 4K 96.0 94.0 91.0 90.0 8K 90.0 89.0 87.0 85.0 LWA 113.0 112.0 110.0 108.0 2K 76.0 75.0 72.0 70.0 4K 69.0 67.0 64.0 63.0 8K 63.0 62.0 60.0 58.0 dBA 86.0 85.0 83.0 81.0 SOUND PRESSURE LEVELS in dB at 30.0 (ft.) ** YVAA0523HMG46 ( Equipped with High Airflow Fans ) Load % Ambient (°F) 63 125 250 500 100.0 95.0 76.0 90.0 89.0 83.0 75.0 80.0 76.0 90.0 89.0 83.0 50.0 65.0 74.0 88.0 87.0 80.0 25.0 55.0 72.0 86.0 85.0 78.0 ** Chiller is assumed to be a point source on a reflecting surface (hemispherical radiation) 1K 80.0 79.0 76.0 74.0 Performance at AHRI Conditions YVAA0523HMG46 Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Volume (gal) 54.0 44.0 1199.9 51.4 Water 0.00010 147.0 Condenser Data Ambient Temp. (°F) Altitude (ft.) 95.0 0 Performance Data EER / COP 10.5 / 3.1 EER IPLV/COP IPLV 14.4 / 4.2 Capacity (Tons) 500.0 If you need a model or capacity between nominal sizes shown here, we can configure units within 1 ton increments. Please contact you JCI Sales Representative for selections and pricing. 84 JOHNSON CONTROLS jOHNSON CONTROLS 16" AIR-COOLED SCREW CHILLER MODEL: YVAA0523HMG46 NOT FOR CONSTRUCTION PRODUCT DRAWING 88" 44 1/8" 95" 8" WATER INLET NOTES: 1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER OPERATION) OR AIR RECIRCULATION ENSURES RATED PERFORMANCE, RELIABLE OPERATION AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISE MINIMUM CLEARANCES INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE DIMINISHED PERFORMANCE. YORK'S UNIT CONTROLS WILL OPTIMIZE OPERATION WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT; HOWEVER, THE SYSTEM DESIGNER MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION, ACCESS TO THE UNIT CONTROL CENTER ASSUMES THE UNIT IS NO HIGHER THEN ON SPRING ISOLATORS RECOMMENDED MINUMUM CLEARANCES: SIDE TO WALL 6' REAR TO WALL - 6'; CONTROL PANEL TO WALL - 4'; TOP - NO OBSTRUCTIONS ALLOWED; DISTANCE BETWEEN ADJACENT UNITS - 10'. NO MORE THEN ONE ADJACENT WALL MAY BE HIGHER THEN THE UNIT. 2. WEIGHTS (LB):SHIPPING - 29,365, OPERATING - 30,722. 3. CENTER OF GRAVITY FROM ORIGIN: X= 225.1", Y= 44.0". 4. WATER CONNECTIONS ARE GROOVED FOR VICTAULIC CONNECTION. 59" 78" 146" 599" 52" 79" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: (8) RIGGHING HOLES EACH SIDE 3 X 2 143" Project Name : examples - Small tonnage BOM Location : Engineer : Contractor : For : 79" 132" 57" 309" 528 5/16" 57" 51" 109" 73" Date : 4/26/2013 9:55:8 Rev. Date : Form : 201.28-EG1 Dwg. Lev. : 01/11 Dwg. Scale : NTS 60" 71" A 12" 10" A 3/4" MOUNTING HOLES (TYP) END END VIEW VIEW A-A B 30" A JOHNSON CONTROLS COMPANY 42" B 8" WATER OUTLET SECTION 12" 3" B-B POWER ENTRY 10" WIDE X 13" HIGH SECTION CONTROL ENTRY 3" WIDE X 11 1/2" HIGH 2 1/2" 2 1/2" MODEL: YVAA0523HMG46 AHRI CAPACITY 500.0 TONS YVAA 201 TO 500 85 86 JOHNSON CONTROLS YCWL 50 to 200 Tons Water Cooled Scroll Chiller jOHNSON CONTROLS 87 88 JOHNSON CONTROLS YCWL RIGGING Delivery and Storage To ensure consistent quality and maximum reliability, all units are tested and inspected before leaving the factory. Units are shipped completely assembled and containing refrigerant under pressure. Units are shipped without export crating unless this has been specified on the Sales Order. If the unit is to be put into storage, before installation, the following precautions should be observed: Ensure that all openings, such as water connections, are securely capped. Do not store where exposed to ambient air temperatures exceeding 107°F (42°C). The unit should be stored in a location where there is minimal activity to limit the risk of accidental physical damage. To prevent inadvertent operation of the pressure relief devices the unit must not be steam cleaned. It is recommended that the unit is periodically inspected during storage. Inspection Immediately upon receiving the unit, it should be inspected for possible damage which may have occurred during transit. If damage is evident, it should be noted in the carrier’s freight bill. A written request for inspection by the carrier’s agent should be made at once. See “Instruction Manual”, Form 50.15-NM for more information and details. Major damage must be reported immediately to your local Johnson Controls representative. Moving the Unit Before moving the unit, ensure that the installation site is suitable for installing the unit and is capable of supporting the weight of the unit and all associated services. The units are designed to be lifted using either lifting chains or a fork lift. Lifting by Crane / Hoist A spreader frame should be used to prevent damage to the unit from the lifting chains (Refer to page 34 of the Operations and Maintenance Guide [Form 201.26-NM1]). NOTE: The unit must only be lifted a the points provided. jOHNSON CONTROLS 89 WATER COOLED SCROLL CHILLER YCWL - 50 to 200 TONS BENEFITS • • • • • • IPLV as high as 25.4 EER provide cost effective operation Designed for low acoustics without additional sound treatment Wide range of options to fit any design requirement HFC-410A Standard for zero ODP and low global warming potential; long service life Multiple scroll compressors offer redundancy and accurate capacity matching Native BACnet MSTP & Modbus communications for BAS integration UPGRADE OPTIONS •Low temperature brine chilling to 15°F • Power Options: • Single Point Power Connection to Terminal Block, Non-fused Disconnect or Circuit Breaker • Multiple Point Power Connection to Circuit Breakers for retrofit projects • Compressor Overloads to limit MCA (ideal for retrofit applications) • Heat Pump (non-reversing) option to 130°F leaving condenser water temperature for energy conservation • Remote Condenser YCRL variant for remote condenser applications • Evaporator Options: • Victaulic Flange Accessory for cooler nozzles • Flow switch: Vapor proof, SPDT, NEMA 4X switch, 150 psig • Vibration Isolators - Neoprene isolators, 1" spring isolators or 2" spring isolators 90 JOHNSON CONTROLS WATER COOLED SCROLL CHILLER YCWL - 50 to 200 TONS PACKAGE DESCRIPTION: Evaporator: •Completely assembled with all piping and wiring ready for field installation • Pressure and operational tested •Provided with HFC-410A charge and initial oil charge •Can be provided with optional overspray coat of Caribbean Blue enamel paint •High efficiency DX cooler, refrigerant in tubes and chilled liquid through baffled shell • Two independent circuits per chiller • Removable heads to access copper tubes • Water vent and drain connections • Insulated with 3/4" closed cell foam •Design working pressure 150 PSIG waterside and 400 PSIG on refrigerant side Compressors: • Reliable suction-gas cooled hermetic scrolls •High efficiency motors with redundant overload protection •Microprocessor controlled compressor staging regulates chiller capacity to 15% of maximum • Design Working Pressure 560 PSIG Condenser: • • • • Cleanable, thru-tube type with removable heads Integral subcooling standard Equipped with relief valves Steel shell and copper tubes Refrigerant Circuit: • Tandem or trio compressors per circuit •Liquid line components include: shut-off valve with charging port, high-absorption removable core filter-drier, solenoid valve, sight glass with moisture indicator, thermal or electronic expansion valves (depending on options) •Entire suction line and liquid line between expansion valve and cooler insulated with flexible closed-cell foam insulation Controls: •All controls housed in a NEMA 1 cabinet with gasket sealed, hinged & latched door • LCD, 40-character display with backlight • Color coded, 32-button sealed keypad jOHNSON CONTROLS 91 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0056SE46 52.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 125.6 12.2 Water 0.00010 22.4 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 23.1/23.1 150.0/150.0 85.0 95.0 153.2 10.6 Water 0.0 0.00025 19.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.1 / 4.7 21.3 / 6.2 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 23.1/23.1 150.0/150.0 3 3515 3648 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 110.0 (1)#12 - #1 92.4 150.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 39.2 39.2 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 92 98.0 150.0 110.0 Capacity (Tons) 52.4 41.1 29.0 14.2 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.4 84.0 67.1 72.4 65.0 67.6 Compressor kW 39.2 26.3 15.4 7.3 Unit Efficiency 16.1 / 4.7 18.8 / 5.5 22.6 / 6.6 23.3 / 6.8 JOHNSON CONTROLS jOHNSON CONTROLS 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0056SE46 NOT FOR CONSTRUCTION 8 15/16" TO RIGGING HOLES Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER 64 1/2" WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES PRODUCT DRAWING 14 1/2" 35 1/2" 29" 17 11/16" 34 5/8" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 3,515, OPERATING - 3,648. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.9", Y= 9.8" 9 1/16" 34" 9" 5/8" MOUNTING HOLES (TYP) 50" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 84 1/2" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 25 7/8" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 5 1/2" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 909 (LB) 915 (LB) 15 1/16" 119 5/8" 101 13/16" 9 7/8" 9 7/8" ORIGIN Y A JOHNSON CONTROLS COMPANY 8 5/8" 30 3/8" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 909 (LB) 915 (LB) X MODEL: YCWL0056SE46 AHRI CAPACITY 52.4 TONS YCWL 50 TO 90 93 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0064SE46 59.9 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 143.6 15.7 Water 0.00010 22.4 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 26.9/26.9 187.0/187.0 85.0 95.0 175.8 13.4 Water 0.0 0.00025 19.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 15.7 / 4.6 19.9 / 5.8 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 26.9/26.9 187.0/187.0 3 3883 4016 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 125.0 (1)#10 - 300 107.6 187.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 45.7 45.7 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 94 114.0 150.0 125.0 Capacity (Tons) 59.9 47.1 33.3 16.3 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.4 84.1 67.2 72.5 65.0 67.6 Compressor kW 45.7 31.1 19.1 9.2 Unit Efficiency 15.7 / 4.6 18.2 / 5.3 20.9 / 6.1 21.2 / 6.2 JOHNSON CONTROLS jOHNSON CONTROLS 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0064SE46 NOT FOR CONSTRUCTION 8 15/16" TO RIGGING HOLES Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER 64 1/2" WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES PRODUCT DRAWING 14 1/2" 35 1/2" 29" 17 11/16" 34 5/8" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 3,883, OPERATING - 4,016. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.9", Y= 10.3" 9 1/16" 50" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 5 1/2" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 9" 5/8" MOUNTING HOLES (TYP) 50" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 84 1/2" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 25 7/8" 1,042 (LB) 966 (LB) 15 1/16" 119 5/8" 101 13/16" 9 7/8" 9 7/8" ORIGIN Y A JOHNSON CONTROLS COMPANY 8 5/8" 30 3/8" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 1,042 (LB) 966 (LB) X MODEL: YCWL0064SE46 AHRI CAPACITY 59.9 TONS YCWL 50 TO 90 95 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0064HE46 62.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 149.6 7.4 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 26.9/26.9 187.0/187.0 85.0 95.0 181.7 6.6 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.5 / 4.8 20.2 / 5.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 26.9/26.9 187.0/187.0 3 4533 4848 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 125.0 (1)#10 - 300 107.6 187.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 45.5 45.5 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 96 114.0 150.0 125.0 Capacity (Tons) 62.4 48.5 33.4 16.3 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.0 83.6 66.4 71.5 65.0 67.5 Compressor kW 45.5 31.0 18.9 9.2 Unit Efficiency 16.5 / 4.8 18.8 / 5.5 21.2 / 6.2 21.3 / 6.2 JOHNSON CONTROLS jOHNSON CONTROLS 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0064HE46 NOT FOR CONSTRUCTION 67 5/8" 1" Project Name : Contractors Guide Location : Engineer : Contractor : For : 11 3/4" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 12 1/4" TO RIGGING HOLES PRODUCT DRAWING 14 1/2" 35 1/2" 29" 17 11/16" 33 13/16" OVERALL WIDTH 23 1/2" 8 1/4" 50" 25 7/8" 34" 9" 124 3/8" 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 85" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,250 (LB) 1,174 (LB) Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 7 1/8" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 4,533, OPERATING - 4,848. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.2" 19 13/16" 9 7/8" 9 7/8" ORIGIN Y A JOHNSON CONTROLS COMPANY 8 3/8" 32" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 1,250 (LB) 1,174 (LB) X MODEL: YCWL0064HE46 AHRI CAPACITY 62.4 TONS YCWL 50 TO 90 97 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0074SE46 67.8 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 162.5 19.9 Water 0.00010 22.4 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 30.4/30.4 225.0/225.0 85.0 95.0 200.2 16.8 Water 0.0 0.00025 19.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 15.2 / 4.5 20.2 / 5.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 26.9/26.9 187.0/187.0 3 4061 4194 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 150.0 (1)#10 - 300 114.6 225.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 53.6 53.6 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 72.2 50.0 22.2 98 122.0 150.0 150.0 Capacity (Tons) 67.8 52.5 38.7 16.2 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.0 83.5 67.8 73.2 65.0 67.3 Compressor kW 53.6 34.1 21.8 9.2 Unit Efficiency 15.2 / 4.5 18.5 / 5.4 21.2 / 6.2 21.2 / 6.2 JOHNSON CONTROLS jOHNSON CONTROLS 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0074SE46 NOT FOR CONSTRUCTION Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER 68 7/8" WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 8 15/16" TO RIGGING HOLES PRODUCT DRAWING 14 1/2" 35 1/2" 29" 17 11/16" 33 13/16" OVERALL WIDTH NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 4,061, OPERATING - 4,194. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.9", Y= 10.4" 23 1/2" 9 1/16" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 5 1/2" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 1" 50" 34" 9" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 84 1/2" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH Y 9 7/8" 9 7/8" ORIGIN X A JOHNSON CONTROLS COMPANY 8 5/8" 30 3/8" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 5/8" MOUNTING HOLES (TYP) 1,106 (LB) 1,106 (LB) 50" 990 (LB) 25 7/8" 101 13/16" 125 15/16" 990 (LB) 21 3/8" MODEL: YCWL0074SE46 AHRI CAPACITY 67.8 TONS YCWL 50 TO 90 99 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0074HE46 72.7 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 174.4 6.0 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 30.4/30.4 225.0/225.0 85.0 95.0 212.0 8.6 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.3 / 4.8 20.7 / 6.1 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 26.9/26.9 187.0/187.0 3 4911 5406 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 150.0 (1)#10 - 300 114.6 225.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 53.4 53.4 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 72.2 50.0 22.2 100 122.0 150.0 150.0 Capacity (Tons) 72.7 54.6 38.9 16.2 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 75.0 82.3 66.4 71.5 65.0 67.1 Compressor kW 53.4 33.7 21.4 9.1 Unit Efficiency 16.3 / 4.8 19.4 / 5.7 21.9 / 6.4 21.3 / 6.2 JOHNSON CONTROLS jOHNSON CONTROLS 14 1/2" 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0074HE46 NOT FOR CONSTRUCTION 74 5/8" Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 12 3/4" TO RIGGING HOLES PRODUCT DRAWING 40" 29" 17 11/16" 33 13/16" OVERALL WIDTH NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 4,911, OPERATING - 5,406. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.3" 1" 5 1/8" 7 1/8" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 8 1/4" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 29" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 83" ORIGIN Y 9 3/8" 33 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" 1,409 (LB) 1,294 (LB) X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" 123 5/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 9" 1,409 (LB) 1,294 (LB) 18 3/4" MODEL: YCWL0074HE46 AHRI CAPACITY 72.7 TONS YCWL 50 TO 90 101 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0084SE46 76.6 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 183.5 24.9 Water 0.00010 22.4 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 30.4/30.4 225.0/225.0 85.0 95.0 224.6 9.5 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 15.8 / 4.6 21.4 / 6.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 30.4/30.4 225.0/225.0 3 4489 4684 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 150.0 (1)#10 - 300 121.6 225.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 58.3 58.3 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 102 129.0 150.0 150.0 Capacity (Tons) 76.6 61.0 44.3 21.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.9 84.6 68.2 73.6 65.0 67.7 Compressor kW 58.3 39.7 23.5 11.1 Unit Efficiency 15.8 / 4.6 18.4 / 5.4 22.7 / 6.7 23.8 / 7.0 JOHNSON CONTROLS jOHNSON CONTROLS 14 1/2" 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0084SE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 35 1/2" 29" 17 11/16" 33 13/16" OVERALL WIDTH 68 7/8" Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 8 15/16" TO RIGGING HOLES NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 4,489, OPERATING - 4,684. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.6" 1" 5 1/8" 7 1/8" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 8 1/4" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 84 1/2" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" X Y 9 7/8" A JOHNSON CONTROLS COMPANY 8 5/8" 30 3/8" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 1,249 (LB) 1,093 (LB) ORIGIN 9 7/8" 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" 125 15/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,249 (LB) 9" 25 7/8" 1,093 (LB) 21 3/8" MODEL: YCWL0084SE46 AHRI CAPACITY 76.6 TONS YCWL 50 TO 90 103 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0084HE46 82.6 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 198.0 7.6 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 30.4/30.4 225.0/225.0 85.0 95.0 239.5 10.6 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.8 / 4.9 21.9 / 6.4 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 30.4/30.4 225.0/225.0 3 5089 5584 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 150.0 (1)#10 - 300 121.6 225.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 58.9 58.9 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 104 129.0 150.0 150.0 Capacity (Tons) 82.6 64.4 44.7 21.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.2 83.8 66.6 71.8 65.0 67.5 Compressor kW 58.9 39.7 23.0 11.0 Unit Efficiency 16.8 / 4.9 19.5 / 5.7 23.3 / 6.8 23.8 / 7.0 JOHNSON CONTROLS jOHNSON CONTROLS 14 1/2" 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0084HE46 NOT FOR CONSTRUCTION 74 5/8" Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 12 3/4" TO RIGGING HOLES PRODUCT DRAWING 40" 29" 17 11/16" 33 13/16" OVERALL WIDTH NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,089, OPERATING - 5,584. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.5" 1" 5 1/8" 7 1/8" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 8 1/4" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 29" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 83" ORIGIN Y 9 3/8" 33 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" 1,474 (LB) 1,318 (LB) X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" 125 11/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 9" 1,474 (LB) 1,318 (LB) 21 1/8" MODEL: YCWL0084HE46 AHRI CAPACITY 82.6 TONS YCWL 50 TO 90 105 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0094SE46 85.9 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 205.8 13.2 Water 0.00010 37.3 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 42.9/42.9 250.0/250.0 85.0 95.0 250.8 11.5 Water 0.0 0.00025 85.0 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.2 / 4.7 21.5 / 6.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 30.4/30.4 225.0/225.0 3 5023 5338 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 200.0 (1)#10 - 300 146.6 250.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 63.8 63.8 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 72.6 50.0 22.6 106 157.0 200.0 175.0 Capacity (Tons) 85.9 66.6 47.8 21.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.0 83.6 67.2 72.5 65.0 67.4 Compressor kW 63.8 41.6 25.4 11.0 Unit Efficiency 16.2 / 4.7 19.2 / 5.6 22.5 / 6.6 23.8 / 7.0 JOHNSON CONTROLS jOHNSON CONTROLS 29" 33 13/16" OVERALL WIDTH WATER-COOLED SCROLL CHILLER MODEL: YCWL0094SE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 14 1/2" 35 1/2" 29" 17 11/16" Project Name : Contractors Guide Location : Engineer : Contractor : For : 11 3/4" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 72 1/4" 1 1/2" RIGGING HOLES 12 1/4" TO RIGGING HOLES NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,023, OPERATING - 5,338. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.9", Y= 10.7" 8 1/4" 23 1/2" 50" 34" 9" 125 15/16" 85" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" Y A JOHNSON CONTROLS COMPANY 8 3/8" 32" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" 1,242 (LB) ORIGIN X 5/8" MOUNTING HOLES (TYP) 1,427 (LB) 50" 101 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,427 (LB) Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 7 1/8" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 1" 25 7/8" 1,242 (LB) 21 3/8" MODEL: YCWL0094SE46 AHRI CAPACITY 85.9 TONS YCWL 50 TO 90 107 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0094HE46 89.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 214.3 8.7 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 42.9/42.9 250.0/250.0 85.0 95.0 258.5 5.4 Water 0.0 0.00025 44.1 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.9 / 5.0 21.9 / 6.4 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 30.4/30.4 225.0/225.0 3 5773 6412 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 200.0 (1)#10 - 300 146.6 250.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 63.5 63.5 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 72.6 50.0 22.6 108 157.0 200.0 175.0 Capacity (Tons) 89.4 68.5 47.9 21.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 75.6 83.1 66.4 71.6 65.0 67.3 Compressor kW 63.5 41.1 25.1 10.9 Unit Efficiency 16.9 / 5.0 20.0 / 5.9 23.0 / 6.7 24.1 / 7.1 JOHNSON CONTROLS jOHNSON CONTROLS 15" 30" WATER-COOLED SCROLL CHILLER MODEL: YCWL0094HE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 42" 29" 33 7/8" OVERALL WIDTH 17 11/16" Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 5 9/16" CONDENSER WATER INLET VICTAULIC CONNECTION 5 9/16" CONDENSER WATER OUTLET VICTAULIC CONNECTION 76 5/8" 1 1/2" RIGGING HOLES 12 3/4" TO RIGGING HOLES 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,773, OPERATING - 6,412. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.6" 5 3/16" 8 5/8" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 8 1/2" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 83" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 108 3/4" Y 9 7/8" 9 3/8" 35 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 1,696 (LB) 1,510 (LB) ORIGIN 9 7/8" X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,696 (LB) 9" 27 1/2" 1,510 (LB) 17 3/16" 121 3/4" MODEL: YCWL0094HE46 AHRI CAPACITY 89.4 TONS YCWL 50 TO 90 109 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0104SE46 92.8 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 222.5 11.0 Water 0.00010 37.3 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 42.9/42.9 250.0/250.0 85.0 95.0 271.0 13.1 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.2 / 4.7 20.9 / 6.1 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 42.9/42.9 250.0/250.0 3 5157 5472 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 225.0 (1)#4 - 500 171.6 250.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 68.9 68.9 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 110 182.0 200.0 200.0 Capacity (Tons) 92.8 72.6 50.9 24.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.3 83.9 66.9 72.2 65.0 67.5 Compressor kW 68.9 46.5 27.6 13.2 Unit Efficiency 16.2 / 4.7 18.7 / 5.5 22.2 / 6.5 22.6 / 6.6 JOHNSON CONTROLS jOHNSON CONTROLS 14 1/2" 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0104SE46 NOT FOR CONSTRUCTION 71 3/4" Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 12 1/4" TO RIGGING HOLES PRODUCT DRAWING 38 1/2" 29" 17 11/16" 33 13/16" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,157, OPERATING - 5,472. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.8" 8 1/4" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 7 1/8" 23 1/2" 50" 9" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 85" Y 32" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" ORIGIN 8 3/8" 1,476 (LB) 1,260 (LB) X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 124 1/8" 101 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,476 (LB) 25 7/8" 1,260 (LB) 19 9/16" MODEL: YCWL0104SE46 AHRI CAPACITY 92.8 TONS YCWL 91 TO 130 111 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0118SE46 110.5 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 264.8 15.1 Water 0.00010 37.3 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 54.5/54.5 310.0/310.0 85.0 95.0 324.5 17.8 Water 0.0 0.00025 26.9 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 15.6 / 4.6 23.5 / 6.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 42.9/42.9 250.0/250.0 3 4983 5298 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 310.0 (1)#4 - 500 194.8 310.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 84.9 84.9 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 71.8 50.0 21.8 112 208.4 250.0 225.0 Capacity (Tons) 117.2 89.7 64.4 27.7 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 75.6 83.0 67.0 72.1 65.0 67.2 Compressor kW 83.1 49.7 29.4 11.9 Unit Efficiency 16.9 / 5.0 21.7 / 6.4 26.3 / 7.7 27.9 / 8.2 JOHNSON CONTROLS jOHNSON CONTROLS 14 1/2" 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0118SE46 NOT FOR CONSTRUCTION 71 3/4" Project Name : Contractors Guide Location : Engineer : Contractor : For : 15 1/2" TO COOLER CONN 4 1/2" CONDENSER WATER INLET VICTAULIC CONNECTION 4 1/2" CONDENSER WATER OUTLET VICTAULIC CONNECTION 1 1/2" RIGGING HOLES 12 1/4" TO RIGGING HOLES PRODUCT DRAWING 38 1/2" 29" 17 11/16" 33 13/16" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 4,983, OPERATING - 5,298. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.8" 8 1/4" 6 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/8" 7 1/8" 23 1/2" 50" 9" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 107 3/4" 85" Y 32" 6 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" ORIGIN 8 3/8" 1,413 (LB) 1,236 (LB) X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 124 1/8" 101 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,413 (LB) 25 7/8" 1,236 (LB) 19 9/16" MODEL: YCWL0118SE46 AHRI CAPACITY 110.5 TONS YCWL 91 TO 130 113 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0118HE46 117.2 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 280.8 14.1 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 54.5/54.5 310.0/310.0 85.0 95.0 334.0 8.4 Water 0.0 0.00025 44.1 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.9 / 5.0 24.7 / 7.2 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 42.9/42.9 250.0/250.0 3 5733 6372 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 310.0 (1)#4 - 500 194.8 310.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 83.1 83.1 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 71.8 50.0 21.8 114 208.4 250.0 225.0 Capacity (Tons) 117.2 89.7 64.4 27.7 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 75.6 83.0 67.0 72.1 65.0 67.2 Compressor kW 83.1 49.7 29.4 11.9 Unit Efficiency 16.9 / 5.0 21.7 / 6.4 26.3 / 7.7 27.9 / 8.2 JOHNSON CONTROLS jOHNSON CONTROLS 15" 30" WATER-COOLED SCROLL CHILLER MODEL: YCWL0118HE46 NOT FOR CONSTRUCTION PRODUCT DRAWING 42" 29" 33 7/8" OVERALL WIDTH 17 11/16" Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 5 9/16" CONDENSER WATER INLET VICTAULIC CONNECTION 5 9/16" CONDENSER WATER OUTLET VICTAULIC CONNECTION 76 5/8" 1 1/2" RIGGING HOLES 12 3/4" TO RIGGING HOLES 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,733, OPERATING - 6,372. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.7" 5 3/16" 8 5/8" 34" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 8 1/2" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 23 1/2" 50" 83" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 108 3/4" Y 9 7/8" 9 3/8" 35 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 1,681 (LB) 1,505 (LB) ORIGIN 9 7/8" X A JOHNSON CONTROLS COMPANY 5/8" MOUNTING HOLES (TYP) 50" 101 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,681 (LB) 9" 25 7/8" 1,505 (LB) 18 3/4" 123 5/16" MODEL: YCWL0118HE46 AHRI CAPACITY 117.2 TONS YCWL 91 TO 130 115 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0132SE46 127.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 305.3 16.5 Water 0.00010 59.8 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 54.5/54.5 310.0/310.0 85.0 95.0 372.0 14.8 Water 0.0 0.00025 35.2 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.1 / 4.7 23.4 / 6.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 54.5/54.5 310.0/310.0 3 5463 6027 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 310.0 (1)#4 - 500 218.0 310.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 94.7 94.7 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 116 231.6 400.0 310.0 Capacity (Tons) 127.4 100.2 70.8 34.7 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.5 84.1 67.2 72.4 65.0 67.5 Compressor kW 94.7 61.0 33.7 15.9 Unit Efficiency 16.1 / 4.7 19.7 / 5.8 25.2 / 7.4 26.2 / 7.7 JOHNSON CONTROLS jOHNSON CONTROLS 29" WATER-COOLED SCROLL CHILLER MODEL: YCWL0132SE46 NOT FOR CONSTRUCTION Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 5 9/16" CONDENSER WATER INLET VICTAULIC CONNECTION 5 9/16" CONDENSER WATER OUTLET VICTAULIC CONNECTION 74 1/2" 1 1/2" RIGGING HOLES 12 3/4" TO RIGGING HOLES PRODUCT DRAWING 14 1/2" 40" 29" 17 11/16" 33 13/16" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 5,463, OPERATING - 6,027. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 50.8", Y= 10.7" 7 3/4" 8 1/8" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION 34" 9" 123 5/16" 101 13/16" Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 108 1/4" 83" X Y A JOHNSON CONTROLS COMPANY 9 3/8" 33 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 9 7/8" 9 7/8" 1,415 (LB) ORIGIN 1,598 (LB) 5/8" MOUNTING HOLES (TYP) 50" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 1,598 (LB) Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 1/4" 23 1/2" 50" 25 7/8" 1,415 (LB) 18 3/4" MODEL: YCWL0132SE46 AHRI CAPACITY 127.4 TONS YCWL 91 TO 130 117 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0157SE46 144.0 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 345.1 17.3 Water 0.00010 57.6 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 54.5/54.5 310.0/310.0 85.0 95.0 419.0 15.3 Water 0.0 0.00025 52.4 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.5 / 4.8 23.5 / 6.9 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 54.5/54.5 310.0/310.0 3 6163 6891 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) 231.6 400.0 250.0 Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type 250.0 () - Notes: Operating Condition Electrical Data Compressor kW Total kW 104.7 104.7 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 118 218.0 310.0 Across the Line Capacity (Tons) 144.0 113.5 80.2 39.3 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.5 84.2 67.3 72.5 65.0 67.5 Compressor kW 104.7 68.1 38.0 17.9 Unit Efficiency 16.5 / 4.8 20.0 / 5.9 25.3 / 7.4 26.3 / 7.7 JOHNSON CONTROLS MODEL: YCWL0157SE46 AHRI CAPACITY 144.0 TONS YCWL 131 TO 200 jOHNSON CONTROLS 119 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0157HE46 148.5 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 355.9 11.6 Water 0.00010 77.0 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 54.5/54.5 310.0/310.0 85.0 95.0 422.4 12.4 Water 0.0 0.00025 59.1 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 17.1 / 5.0 24.2 / 7.1 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 54.5/54.5 310.0/310.0 3 6863 7807 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) 231.6 400.0 250.0 Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type 250.0 () - Notes: Operating Condition Electrical Data Compressor kW Total kW 104.3 104.3 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 75.0 50.0 25.0 120 218.0 310.0 Across the Line Capacity (Tons) 148.5 116.8 81.4 39.9 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 76.5 84.1 66.9 72.1 65.0 67.5 Compressor kW 104.3 67.2 37.7 17.8 Unit Efficiency 17.1 / 5.0 20.9 / 6.1 25.9 / 7.6 26.9 / 7.9 JOHNSON CONTROLS MODEL: YCWL0157HE46 AHRI CAPACITY 148.5 TONS YCWL 131 TO 200 jOHNSON CONTROLS 121 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0177SE46 166.6 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 399.3 14.2 Water 0.00010 77.0 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 49.2/49.2/49.2 242.0/242.0/242.0 85.0 95.0 477.9 15.3 Water 0.0 0.00025 59.1 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 17.1 / 5.0 25.4 / 7.4 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 49.2/49.2 242.0/242.0 3 7318 8262 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 300.0 (1)#4 - 500 246.0 242.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 117.1 117.1 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 80.0 60.0 40.0 20.0 122 258.0 400.0 300.0 Capacity (Tons) 166.6 141.0 108.3 73.3 35.6 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 78.8 87.1 71.0 77.2 65.0 69.1 65.0 67.0 Compressor kW 117.1 80.8 52.8 31.0 15.2 Unit Efficiency 17.1 / 5.0 20.9 / 6.1 24.6 / 7.2 28.4 / 8.3 28.2 / 8.3 JOHNSON CONTROLS jOHNSON CONTROLS 15" 30" WATER-COOLED SCROLL CHILLER MODEL: YCWL0177SE46 NOT FOR CONSTRUCTION 23 1/2" 9" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 5 9/16" CONDENSER WATER INLET VICTAULIC CONNECTION 5 9/16" CONDENSER WATER OUTLET VICTAULIC 77 1/2" CONNECTION 1 1/2" RIGGING HOLES 17 3/4" TO RIGGING HOLES PRODUCT DRAWING 41" 29" 17 11/16" 34 13/16" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 7,318, OPERATING - 8,262. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 62.9", Y= 11.7" 34" 9" 50" 132 3/4" 102" 5/8" MOUNTING HOLES (TYP) Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 37 5/8" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 3/16" 7 1/8" 50" 2,229 (LB) 1,902 (LB) 14 7/8" 143 7/16" 125 13/16" Y 11 7/8" 36 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 10 3/8" A JOHNSON CONTROLS COMPANY 2,229 (LB) 1,902 (LB) ORIGIN 10 3/8" X MODEL: YCWL0177SE46 AHRI CAPACITY 166.6 TONS YCWL 131 TO 200 123 Water Cooled Scroll Chiller Performance Specification Model No. Capacity (Tons) Volts/Ph/Hz Refrigerant YCWL0198SE46 198.4 460/3/60 R410A Evaporator Data EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) Condenser Data 54.0 44.0 475.6 19.6 Water 0.00010 77.0 Circuit Compressor RLA Compressor Start Current (LRA) EWT (°F) LWT (°F) Flow Rate (gpm) Pressure Drop (ft.) Fluid Fouling Factor Water Vol. (gal) 1 49.2/49.2/49.2 242.0/242.0/242.0 85.0 95.0 566.2 20.4 Water 0.0 0.00025 59.1 Performance Data EER / COP EER IPLV/COP IPLV Physical Data 16.8 / 4.9 24.8 / 7.3 Rigging Wt. (lbs.) Operating Wt. (lbs.) Electrical Data 2 49.2/49.2/49.2 242.0/242.0/242.0 3 7673 8617 4 Single Point Min. Circuit Ampacity Min. Non-Fused Disconnect (Amps) Min. Circuit Breaker (Amps) Max. Circuit Breaker (Amps) Wire Range (Lug Size) * Grounding Wire Lug Size Total Amps Inrush (PW) Amps Starter Type Notes: 350.0 (1)#4 - 500 295.2 242.0 Across the Line Operating Condition Electrical Data Compressor kW Total kW 141.9 141.9 RATED AND CERTIFIED IN ACCORDANCE WITH AHRI STANDARD 550/590. * Use Copper Conductors only Load % 100.0 83.3 66.7 50.0 33.3 16.7 124 308.0 400.0 350.0 Capacity (Tons) 198.4 172.0 144.2 110.2 73.0 35.8 Part Load Rating Data Cond. EWT (°F) Cond. LWT (°F) 85.0 95.0 79.7 88.1 74.1 81.0 67.2 72.4 65.0 68.4 65.0 66.7 Compressor kW 141.9 106.6 76.0 50.6 31.5 15.5 Unit Efficiency 16.8 / 4.9 19.4 / 5.7 22.8 / 6.7 26.1 / 7.6 27.8 / 8.1 27.7 / 8.1 JOHNSON CONTROLS jOHNSON CONTROLS 15" 30" WATER-COOLED SCROLL CHILLER MODEL: YCWL0198SE46 NOT FOR CONSTRUCTION 23 1/2" 9" 8 5/8" EVAP LIQUID INLET VICTAULIC CONNECTION Project Name : Contractors Guide Location : Engineer : Contractor : For : 16" TO COOLER CONN 5 9/16" CONDENSER WATER INLET VICTAULIC CONNECTION 5 9/16" CONDENSER WATER OUTLET VICTAULIC 77 1/2" CONNECTION 1 1/2" RIGGING HOLES 17 3/4" TO RIGGING HOLES PRODUCT DRAWING 41" 29" 17 11/16" 34 13/16" OVERALL WIDTH 1" NOTES: 1. CLEARANCES - RECOMMENDED MINIMUM CLEARANCES TO SERVICE THE UNITS ARE AS FOLLOWS: REAR TO WALL: 20" FRONT TO WALL: 36" TOP: 43" TUBE CLEARANCE AND REMOVAL, 4 COMPR UNITS: 132" (NOT SHOWN) TUBE CLEARANCE AND REMOVAL, 6 COMPR UNITS: 156" (NOT SHOWN) 2. WEIGHTS (LB):SHIPPING - 7,673, OPERATING - 8,617. 3. EACH RELIEF VALVE SHOULD BE PIPED IN A MANNER CONSISTENT WITH ASHRAE / ANSI 15 AND ALL LOCAL CODE REQUIREMENTS SO THAT IF THE VALVE IS ACTIVATED THE RELEASE OF HIGH PRESSURE GAS AND LIQUID CANNOT BE A DANGER OR CAUSE INJURY. REFER TO FORM 201.26.EG1 4. CENTER OF GRAVITY FROM ORIGIN: X= 62.9", Y= 11.7" 34" 9" 143 7/16" 50" 102" 5/8" MOUNTING HOLES (TYP) Date : Rev. Date : Form : 201.26-EG1 Dwg. Lev. : 10/07 Dwg. Scale : NTS 132 3/4" 125 13/16" POWER ENTRY IS ON TOP OF PANEL 12" WIDE X 6" HIGH 37 5/8" Sold To : Cust Purch Order# : York Contract# : UNIT TAG: 5 3/16" 7 1/8" 50" 2,371 (LB) 1,938 (LB) 14 7/8" Y 11 7/8" 36 1/4" 8 5/8" EVAP LIQUID OUTLET VICTAULIC CONNECTION 10 3/8" A JOHNSON CONTROLS COMPANY 2,371 (LB) 1,938 (LB) ORIGIN 10 3/8" X MODEL: YCWL0198SE46 AHRI CAPACITY 198.4 TONS YCWL 131 TO 200 125 126 JOHNSON CONTROLS Printed on recycled paper Form: 050.05-TD1 (313) Supersedes: 050.05-TD1 (309) © 2008 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.johnsoncontrols.com