Contents Next Previous Bussmann® North American FWP 700V Type 5-1200A ® Electrical Characteristics Ordering Information I2t (A2 Sec) Rated Current Clearing Watts Part Carton RMS-Amps Pre-arc at 700V Loss Number Qty. 5 1.6 10 1.5 FWP-5B __________________________________________________________________________ 10 3.6 20 4 FWP-10B __________________________________________________________________________ 15 10 75 5.5 FWP-15B __________________________________________________________________________ 20 26 180 6 FWP-20B __________________________________________________________________________ 25 44 340 7 FWP-25B __________________________________________________________________________ 10 Dimensions Carton Weight (lbs) Figure Number Curves See Page or (BIF #) page 24 2.25 (35785316) 30 58 450 9 FWP-30B ______________________________________________________________________________________ ____________ 35 34 160 12 FWP-35B __________________________________________________________________________ 40 76 320 12 FWP-40B __________________________________________________________________________ 50 135 600 12 FWP-50B __________________________________________________________________________ 5 1.21 60 210 950 15.5 FWP-60B _________________________________________________________________________________________________ page 24 70 305 2000 18 FWP-70B __________________________________________________________________________ (35785308) 80 360 2400 21 FWP-80B __________________________________________________________________________ 0.24 90 415 2700 25 FWP-90B __________________________________________________________________________ 100 540 3500 27 FWP-100B __________________________________________________________________________ ____________ 125 1800 7300 28 FWP-125A __________________________________________________________________________ FWP 150 2900 11700 32 FWP-150A __________________________________________________________________________ Fig. 1 0.65 700V __________________________________________________________________________ 175 4200 16700 35 FWP-175A 200 5500 22000 43 FWP-200A __________________________________________________________________________ page 25 ____________ 225 7700 31300 45 FWP-225A __________________________________________________________________________ (361) 250 10500 42500 48 FWP-250A __________________________________________________________________________ 300 17600 71200 58 FWP-300A __________________________________________________________________________ 1 1.17 350 23700 95600 65 FWP-350A __________________________________________________________________________ 400 31000 125000 78 FWP-400A __________________________________________________________________________ ____________ 450 36400 137000 94 FWP-450A __________________________________________________________________________ 500 45200 170000 107 FWP-500A __________________________________________________________________________ 2.39 600 66700 250000 122 FWP-600A __________________________________________________________________________ ____________ 700 54000 300000 125 FWP-700A __________________________________________________________________________ 800 78000 450000 140 FWP-800A __________________________________________________________________________ 1.21 _______________________ 900 91500 530000 150 FWP-900A __________________________________________________________________________ 1000 120000 600000 170 FWP-1000A __________________________________________________________________________ 1200 195000 1100000 190 FWP-1200A Interrupting rating 200kA RMS Symmetrical. Watts loss provided at rated current. ( 700 Vdc/Interrupting rating 50kA) U.L. Recognition on 5 through 800 amperes only. CSA Component Acceptance: 35 - 100A & 700 - 1200A. See accessories on page 20. 6.60 Fig. 2 ___________ Fig. 3 1 kg = 2.2 lbs R BIF document: 720012 16 page 24 (35785308) For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 1 lb = 0.45 kg Contents Previous Next Bussmann® North American 5-1200A FWP 700V ® Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E g , (RMS). Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 2 1.5 1.0 Kp 0.8 UL K 1.6 1.4 1.2 103 1.0 2) 0.5 0.6 0.5 1) 0.4 2) 8 0.3 0.2 0.3 6 5 1) 3) Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 0.2 4 0.15 316 Eg 460 604 Eg 3 300 700 1) 35-100 Amp Range 2) 125-600 Amp Range 3) 700-1200 Amp Range 400 500 600 Ib 0.1 30 40 50 700 60 70 80 90 100% 1) 125-600 Amp Range 2) 35-100 & 700-1200 Amp Range Dimensions Fig. 1: 5-800 Amp Range Fig. 2: 900-1000 Amp Range Fig. 3: 1200 Amp Range 3.500 1.375 J 0.125 0.500 5.966 7.594 A D E C 9.590 6.840 3.844 3.844 10.844 5.154 1.031 0.625 1.625 1.750 0.625 2.750 0.750 0.500 4.250 F 3.500 G H B Order # Fig. FWP-5B-30B 1 A B C D E F G H J 2.870 0.563 1.855 2.477 2.477 0.250 0.405 0.063 0.250 FWP-35B-60B 1 4.375 0.813 2.750 3.708 3.312 0.344 0.725 0.125 0.542 FWP-70B-100B 1 4.406 0.947 2.594 3.625 3.563 0.344 0.750 0.125 0.375 FWP-125A-200A 1 5.090 1.500 2.840 4.190 3.500 0.410 1.000 0.250 0.750 FWP-225A-400A 1 5.090 2.000 2.840 4.280 3.530 0.410 1.500 0.250 0.780 FWP-450A-600A 1 7.090 2.500 2.840 5.720 4.190 0.530 2.000 0.380 1.300 FWP-700A-800A 1 6.630 2.000 2.844 5.562 5.062 0.625 1.500 0.250 0.875 FWP-900A-1000A 2 See Drawing FWP-1200A 3 See Drawing Dimension in inches. 1mm = 0.0394∑ 1∑ = 25.4mm BIF document: 720012 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 17 Contents Next Previous Bussmann® North American Curves FWP 700V (5-30)B FWP 700V (35-100)B & (700-1200)A Time-Current Curve Time-Current Curve 104 104 6 4 6 4 2 2 103 103 6 4 6 4 2 2 6 4 6 4 2 Virtual Pre-Arcing Time In Seconds Virtual Pre-Arcing Time In Seconds 2 101 6 4 2 100 6 4 FWP-5B FWP-10B FWP-15B FWP-20B FWP-25B FWP-30B 2 10–1 6 4 101 6 4 FWP-35B FWP-40B FWP-50B FWP-60B FWP-70B FWP-80B FWP-90B FWP-100B 2 100 6 4 2 10–1 6 4 2 10–2 2 6 4 10–2 6 4 2 10–3 2 6 4 10–3 6 4 2 10–4 2 10–4 FWP-700A FWP-800A FWP-900A FWP-1000A FWP-1200A 102 102 2 4 6 8 101 2 4 6 8 2 102 4 6 8 2 4 6 8 2 4 6 8 2 103 Prospective Current In Amperes RMS 102 103 4 6 8 104 Prospective Current In Amperes RMS Peak Let-Through Curve Peak Let-Through Curve 104 106 FWP-1200A 6 FWP-1000A 6 4 FWP-800A 4 FWP-700A 2 FWP-30B FWP-25B 2 6 104 4 Peak Let-Through Current Peak Let-Through Current 103 2 FWP-20B FWP-15B FWP-10B FWP- 5B 102 6 6 4 2 4 103 2 6 FWP-100B 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 4 2 FWP-70B FWP-60B Prospective Short-Circuit Current FWP-50B 2 FWP-40B FWP-35B 102 2 102 4 6 2 103 4 6 2 4 104 Prospective Short-Circuit Current BIF document: 35785316 24 BIF document: 35785308 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 2 6 105 Contents Next Previous Bussmann® North American Curves FWP 700V (125-600)A FWJ 1000V (35-600)A Time-Current Curve Time-Current Curve 103 104 6 4 2 103 102 6 4 2 FWP-150A FWP-200A FWP-300A FWP-400A FWP-600A FWJ-200A FWJ-250A FWJ-300A FWJ-350A FWJ-400A FWJ-500A FWJ-600A 6 4 2 Virtual Pre-Arcing Time In Seconds Virtual Pre-Arcing Time In Seconds 101 102 100 10–1 101 6 4 2 100 6 4 2 10–1 6 4 –2 10 2 10–2 6 4 10–3 2 10–3 FWJ-40A FWJ-50A FWJ-60A FWJ-70A FWJ-80A FWJ-90A FWJ-100A FWJ-125A FWJ-150A FWJ-175A 6 4 10–4 102 2 103 104 105 10–4 2 102 Prospective Current In Amperes RMS 4 6 8 2 103 4 6 8 104 Prospective Current In Amperes RMS Peak Let-Through Curve Peak Let-Through Curve 2 105 FWJ-2000A FWJ-1800A FWJ-1600A FWJ-1400A FWJ-1250A FWJ-1000A FWJ-600A FWJ-800A FWJ-400A FWJ-500A FWJ-350A FWJ-300A FWJ-250A FWJ-200A FWJ-175A FWJ-150A FWJ-125A FWJ-100A FWJ-90A FWJ-80A FWJ-70A FWJ-60A FWJ-50A FWJ-40A B 105 6 4 Peak Let-Through Current FWP-600A FWP-400A FWP-300A FWP-200A FWP-150A Peak Let-Through Current 2 104 104 6 4 2 103 103 6 4 A 2 102 102 2 4 6 103 2 4 6 104 2 4 6 105 2 4 6 Prospective Short-Circuit Current Symmetrical RMS 2 10 102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS BIF document: 361 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 BIF document: 35785303 25