rubber insulated cables

advertisement

with medium and the hand electrode ships. Flame retardant.

mechanical stress.

along conveyor systems with very high for surface mining and for installation

For the connection of large mobile machines under very high mechanical connection of mobile equipment and or without protective conductors for the

Rubber insulated flexible cables with p hes se lly the

. In oac uit u ecia oms il-c rs, circ afe.

esp u-to y ro

ra ortlt s ble fau

sh strib

da g in

ca

be atin rths in ted d di d to ll a uit r d ea sula ere s an stem

, as ortnsid

V an

we circ r in bbe ses

sh

sy e co

000

ru

ar ing to 1

bu

as cial and cranes.

and able les tch

Spe cab swi suit for building machinery, conveyors, shifts simultaneous tensile and torsional stress, frequent winding and unwinding with stress, especially for applications with

Trailing cables used for high mechanical installation in a waterway.

for under-water power transmission or floors, machinery and towers. Unsuitable can also be permanently laid, e.g. on walls, withstand medium mechanical stresses and temperature up to 40 C. They are able to of about 10 m and a maximum water o site drainage down to a water depth submersible motor pumps for construction

These cables are ideal for the connection of conduit together.

only to the cables, and not to cable and tests for smoke and corrosive gases relate required in the case of burning. The defined emission of smoke and corrosive gases is particularly for situations in which low

For indoor and temporary outdoor, where heat dissipation is inhibited.

temperature, UV and infra red radiation, insulation is exposed to high ambient luminaires, lighting fittings where conductor for use in installation of recessed flexible cords are especially recommended

CPE sheathed insulated and Silicone rubber loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining, and at quarries and building sites.

equipment such excavators and spreaders

For electrical and electronic equipment of

For use between the welding equipment

Heavy duty heat resisting flexible cables for use at temperaure of conductor 90 deg C

÷240 16.0

÷1.5

0.75

1.5÷16.0

1÷25

1÷185

1÷185

1÷25

1.5÷2.5

4

1.5÷2.5

1÷25

1÷185

1÷240

1÷25

1.5÷500

1.5÷500

1.5÷4

70

1.5÷150

÷630 4.0

1.5÷4

1.5÷50

1.5÷70

1÷185

1.5÷120

1.5÷400

+3x95/3

÷3x185

25+3x25/3

0.75÷2.5

0.5÷2.5

1.5÷400

Application

]

2

[mm sections

Cross

3

2

1

5

4

6÷36

6÷18

2

1

3÷4

5

4

7

5

3÷4

7÷18

4

2÷3

2

1

3÷4

6÷7

5

8÷12

3

2c÷27

PR cores

1 PR÷10

1c

1 cores

1c÷5 of cores

Number

[V] voltage

Nominal

600/1000

150/250

300

300/500

450/750

450/750

450/750

1,8/3 kV

0,6/1 kV

3,6/6 kV

÷18/30kV

3,6/6 kV

600/1000

600/1000

CABLES IN RUBBER

19

DIN VDE 0282-12

BS 6500

BS 7919

DIN VDE 0282-13

Standard

BS 638 1996

BS 7917 1999

BS 7919 2001

DIN VDE 0282-16

DIN VDE 0250-814

DIN VDE 0250-602

DIN VDE 0250-812

DIN VDE 0250-813

NSGAFCÖU

NSGAFÖU

NSSHCÖU

NSSHÖU

NSHTÖU

(N)TSCGEWOU

R(N)TSCGEWOU

0361 TQ

658-FR

H07BN4-F

H07ZZ-F

05SN4-F

H07RN8-F

Designation

RUBBER INSULATED CABLES

Designation

Type 4

H05RNH2-F

H05RR-F

H05RN-F

H05RN-F

H07RN-F

H05BB-F

H07BB-F

H05BN4-F

UK Ref. 318*TQ

H07BN4-F

UK Ref. 638*TQ

Standard

Nominal voltage

[V]

BS 6195

CABLES IN RUBBER

Category

A, C, D,

E, F

Number of cores

1

DIN VDE 0282-8

DIN VDE 0282-4

BS 6500

BS 7919

NF C 32-102-4

DIN VDE 0282-4

BS 6500

NF C 32-102-4

DIN-VDE 0282-8

DIN VDE 0282-4

BS 7919

NF C 32-102-4

DIN VDE 0282-12

BS 6500, BS 7919

DIN VDE 0282-12

BS 7919

DIN VDE 0282-12BS

6500

BS 6007

BS 7919

300/500

300/500

300/500

300/500

450/750

300/500

450/750

300/500

450/750

2

2

3÷4

5

2÷3

1

1

2

3

4

5

6÷36

6÷18

2

3÷4

5

1

2

3

4

5

2÷3

4

1

2

3

4

5

12÷36

Cross sections

[mm 2 ]

Application

0.5÷2.5

0.75÷2.5

1.5÷500

1÷25

1÷240

1÷185

1÷25

1.5÷2.5

0.75÷400

1.5÷2.5

0.75÷2.5

0.75÷6

0.75÷2.5

0.75÷1

0.75÷1.5

1.5÷500

1÷25

1÷240

1÷185

1÷25

1.5÷2.5

4

0.75÷2.5

0.75÷6

0.75÷2.5

1.5÷500

1÷25

1÷300

1÷300

1÷25

Single cores flame retardant composite rubber insulated cables for coil lead.

Cables for decorative chains used for lamp-holder for indoor and outdoor use Flat two core cables for temporary decorative illumination only.

In domestic premises, kitchens and offices for supplying portable or light mobile appliances which are subject to low mechanical stresses (e.g. vacuum cleaners, electric irons cooking appliances). Not suitable for permanent use outdoors, in agriculture, in industrial.

In domestic premises, kitchens and offices for supplying portable or light mobile appliances which are subject to low mechanical stresses (e.g. vacuum cleaners, electric irons cooking appliances). Also suitable for permanent use outdoors for ordinary duty applications.

Heavy-duty flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air in agriculture plants, eg. for industrial and agricultural workshop appliances, large boiling installations, heating plates, inspections lamps, electrical tools such as drills, circular saws, domestic electric tools, and also for transportable motors or machines on building sites or in agricultural workings etc.

For general use in domestic premises, kitchens and offices and for supplying appliances where the cables are subjected to low mechanical stresses (eg., cooking appliances, soldering irons, toasters).

Suitable for use at maximum conductor temperature of 90 o C and at a minimum temperature of –40 o C.

In dry, humid or moist rooms, in open air, in workshops; for medium mechanical stresses, eg. for industrial and agricultural workshop appliances, large boiling installations, heating plates, inspection lamps, electrical tools such as drills, circular saws, domestic electric tools, and also for transportable motors or machines on building sites or in agricultural workings, etc.

Also for low temperature outdoor use with caravans, car heaters and at camping sites.

Suitable for use at maximum conductor temperature of 90 o C and at a minimum temperature of –40 o C.

85°C EPR insulated and HOFR sheathed flexible cords in domestic premises, kitchens and offices. Suitable for hot situations (e.g. night storage heaters, immersion heaters) and for situations involving contact with oils and grease.

Suitable for use at maximum conductor temperature of 90 o C.

18 for use particularly in underground mines.

Flexible electric rubber insulated cables

For wiring mobile equipment & Wiring interconnection of mining equipment in underground coalmines.

Mining cable for use

Shuttle Car Cable for underground mining.

for use in mines

Flexible electric trailing cables for underground mining.

for use in mines

Flexible electric trailing cables

Application

16÷50 3 + 3 + 1 100 1100/1

30

6÷120+1÷14+2,5

÷3x95+2x16+1x50

3x25+2x10+1x16

1.5 & 16

÷3x95+3x16

3x25+3x10

÷3x95+3x16

3x70+3x10

÷3x95+3x16

3x25+3x10

÷3x150+3x25

3x25+3x10

÷3x95+3x16

3x25+3x10

1.5; 16

1.5

1.5; 4; 10

10÷95

+16÷70

16÷120+16÷50

]

2

[mm sections

Cross

4÷16 of cores

Number

3 + 1

3 + 3

3 + 3

3 + 3 + 3

3 + 3

3 + 3

3 + 3

6

4

3

18, 30

2, 7, 16,

3 + 3 + 1

2 to 16 kV

1,1/1,1 kV

3,8/6,6 kV

3,8/6,6 kV

6,35/11 kV

1,9/3,3

1100V

640/

600/1000

600/1000 kV

0,64/1,1

[V] voltage

Nominal

1802

AS/NZS

1972

AS/NZS

Standard

MINING CABLES

BS 6708:1998

SANS 1520 Part 1

SANS 1520 Part 2

AS/NZS 1802:1995

AS/NZS-1972: 2002

Type 7

Type 241.1

Screened

Collectively

& Covered

Insulated

Type 1 PVC

Mining Cables

Type 275

Mining Cables

Type 2S

Type 66 ECC

Type 66

Type 63

Type 611

Type 61 B

Type 61 A

Designation

Type 41

BARE AND INSULATED OVERHEAD CONDUCTORS

Designation

PVC-covered stranded hard drawn copper conductors

Type 8, Type 16

PVC-covered aluminium stranded conductors

Type 8

PVC-covered aluminium conductors, steel reinforced

Type 16

BLX

PAS

Standard

Nominal voltage

[V]

Number of cores

PVC COVERED OVERHEAD CONDUCTORS

Cross sections

[mm 2 ]

BS 6485: 1999

BS 6485: 1999

BS 6485: 1999

650

650

650

1

1

1

Application

14÷100

22÷200

25÷200

PVC-covered conductors for overhead transmission lines. Also suitable for other purposes, but they should be used only in appropriate situations and with due regard

1400 to any relevant safety regulations.

Type 8 is suitable for:

1400

1400 crossing of telecommunication lines to guard against contact; proximities to telecommunication lines to guard against contact; lines (particularly service lines) accessible from buildings.

Type 16 is suitable for crossings of telecommunication lines and proximities to them.

XLPE COVERED OVERHEAD CONDUCTORS

SS 424 14 63

ZN-96/MD-13-K1 204

SFS 5791

24 kV

24 kV

1

1

50÷185

50÷150

Overhead single core cables with aluminium alloy conductor and XLPE insulation, for overhead power transmission

lines up to 24 kV.

Overhead single core cables with aluminium alloy conductor and XLPE insulation, for overhead power transmission

lines up to 24 kV.

AERIAL BUNDLED CONDUCTORS

EX

ABC

AXKA

XOO-A

XOO/O-A

AMKA

NEN 73.77

BS 7870-5: 1999

HD 626 S1: 1996 |

A2: 2002

Part 6- sec. D

JUS N.C5.250

SFS 2200

600/1000

600/1000

600/1000

600/1000

2÷4

2÷4

2÷6

2÷5

25÷95

25÷120

16÷120

16÷120

Overhead selfsupporting cables with aluminium conductors and thermoplastic polyethylene insulation, for overhead power transmission lines 220/380 V.

Overhead selfsupporting cables with aluminium conductors and XLPE insulation, for overhead power transmission lines

220/380 V.

Overhead selfsupporting cables with aluminium phases conductors and aluminium alloy neutral conductor, XLPE insulation, for overhead power transmission lines 220/380 V.

Overhead selfsupporting cables with aluminium phases conductors and aluminium alloy neutral conductor, thermoplastic polyethylene insulation, for overhead power transmission

lines 220/380 V.

NFA2X

1-AES

AsXS

AsXSn

626/A1

HD 621 S1

Part 1,2,4F-1

AS/NZS 5000,1:2003

600/1000

HD 6261.S1: 1996/

A1:1997

(CSIV 34 7614-1)

WT-92/K-396

ZN-94/MP-13-K2 108

600/1000

1,4

4+1

4+2

1

2

4

4+1

4+2

25÷70

70+35

70+35

25÷70

16+35

16+120

35÷120

+25÷35

+25÷35

XLPE insulated aluminium conductors for overhead transmission lines.

XLPE insulated aluminium conductors for overhead transmission lines.

31

Overhead single core cables with aluminium

Overhead single core cables with aluminium polyethylene insulation, for overhead power aluminium conductors and XLPE insulation, insulation, for overhead power transmission appropriate situations and with due regard

XLPE insulated aluminium conductors

XLPE insulated aluminium conductors thermoplastic polyethylene insulation, aluminium conductors and thermoplastic for overhead power transmission lines alloy conductor and XLPE insulation, purposes, but they should be used only in lines (particularly service lines) alloy conductor and XLPE insulation,

PVC-covered conductors for overhead

Overhead selfsupporting cables with

Overhead selfsupporting cables with

Overhead selfsupporting cables with

Overhead selfsupporting cables with aluminium phases conductors and aluminium phases conductors and to any relevant safety regulations. for overhead power transmission for overhead power transmission for overhead power transmission aluminium alloy neutral conductor, of telecommunication lines and for overhead transmission lines.

for overhead transmission lines.

lines to guard against contact; lines to guard against contact; transmission lines 220/380 V.

aluminium alloy neutral conductor, XLPE accessible from buildings.

lines up to 24 kV.

lines up to 24 kV.

lines 220/380 V.

lines 220/380 V.

220/380 V.

50÷185

50÷150

25÷120

16÷120

16÷120

25÷95

16+35

25÷70

16+120

35÷120

+25÷35

50÷120

+25÷35

70+35

70+35

25÷70

2÷4

2÷4

2÷6

2÷5

2

1

4

4+1

4+2

4+1

1,4

4+2

00 /10 600

00 /10 600

31

600/1000

600/1000

600/1000

600/1000

1

1

24 kV

24 kV proximities to them.

Application proximities to telecommunication crossing of telecommunication

Type 8 is suitable for:

1400

1400

1400

Type 16 is suitable for crossings transmission lines. Also suitable for other

14÷100

22÷200

25÷200

]

2

[mm sections

Cross of cores

Number

1

1

1

650

650

650

[V] voltage

Nominal

AERIAL BUNDLED CONDUCTORS

(CSIV 34 7614-1)

A1:1997

WT-92/K-396

HD 6261.S1: 1996/

HD 621 S1

626/A1

Part 1,2,4F-1

DIN VDE 0276-

AS/NZS 5000,1:2003

ZN-94/MP-13-K2 108

SFS 2200

Part 6- sec. D

A2: 2002

HD 626 S1: 1996 |

BS 7870-5: 1999

NEN 73.77

Standard

SFS 5791

ZN-96/MD-13-K1 204

SS 424 14 63

JUS N.C5.250

BS 6485: 1999

BS 6485: 1999

BS 6485: 1999

PVC COVERED OVERHEAD CONDUCTORS

XLPE COVERED OVERHEAD CONDUCTORS conductors, aluminium

Type 16

PVC-covered

Type 8 conductors stranded aluminium

PVC-covered steel reinforced

Type 8, Type 16 conductors drawn copper stranded hard

PVC-covered

PAS

BLX

AXKA

ABC

EX

XOO/O-A

XOO-A

AMKA

AsXS

1-AES

AsXSn

NFA2X

Designation

BARE AND INSULATED OVERHEAD CONDUCTORS

Designation Standard

MINING CABLES

Nominal voltage

[V]

Number of cores

Cross sections

[mm 2 ]

3 + 1 4÷16

Application

Type 41

Type 61 A

Type 61 B

Type 63

Type 66

Type 611

Type 66 ECC

SANS 1520 Part 1

0,64/1,1 kV

3 + 3

3x25+3x10

÷3x95+3x16

1,9/3,3 kV

3 + 3

3x70+3x10

÷3x95+3x16

3x25+3x10

÷3x150+3x25

3,8/6,6 kV

3 + 3

3x25+3x10

÷3x95+3x16

SANS 1520 Part 2

6,35/11 kV

3 + 3

3x25+3x10

÷3x95+3x16

3,8/6,6 kV

3 + 3

3x25+2x10+1x16

÷3x95+2x16+1x50

Flexible electric trailing cables for use in mines for underground mining.

Flexible electric trailing cables for use in mines for underground mining.

Type 241.1

Type 7

Type 2S

AS/NZS 1802:1995

1,1/1,1 kV

3 + 3 + 3 6÷120+1÷14+2,5

Mining cable for use in underground coalmines.

BS 6708:1998

640/

1100V

3 + 3 + 1

16÷120+16÷50

+16÷70

AS/NZS-1972: 2002 600/1000

2, 7, 16,

18, 30

4

6

3

1.5

1.5; 16

1.5; 4; 10

10÷95

Flexible electric rubber insulated cables for use particularly in underground mines.

Mining Cables

Type 1 PVC

Insulated

& Covered

Collectively

Screened

AS/NZS

1972

600/1000 2 to 16 1.5 & 16

For wiring mobile equipment & Wiring interconnection of mining equipment

Mining Cables

Type 275

AS/NZS

1802

1100/1100 3 + 3 + 1 16÷50 Shuttle Car Cable

30 building sites or in agricultural workings, etc. lamps, electrical tools such as drills, circular lamp-holder for indoor and outdoor use Flat mechanical stresses (e.g. vacuum cleaners, mechanical stresses (e.g. vacuum cleaners, caravans, car heaters and at camping sites. machines on building sites or in agricultural

In domestic premises, kitchens and offices

In domestic premises, kitchens and offices appliances where the cables are subjected tools, and also for transportable motors or stresses, eg. for industrial and agricultural

Also for low temperature outdoor use with

85°C EPR insulated and HOFR sheathed two core cables for temporary decorative large boiling installations, heating plates,

Heavy-duty flexible cables are suited for air in agriculture plants, eg. for industrial as drills, circular saws, domestic electric

Single cores flame retardant composite suitable for permanent use outdoors, in suitable for permanent use outdoors for inspections lamps, electrical tools such

Suitable for use at maximum conductor

C.

o temperature of 90 kitchens and offices. Suitable for hot situations (e.g. night storage heaters, immersion heaters) and for situations involving contact with oils and grease.

Application use for medium mechanical stress in dry, damp and wet areas as well as in open and agricultural workshop appliances, flexible cords in domestic premises, ordinary duty applications.

electric irons cooking appliances). Also for supplying portable or light mobile appliances which are subject to low electric irons cooking appliances). Not agriculture, in industrial.

for supplying portable or light mobile appliances which are subject to low

Cables for decorative chains used for

C.

o o temperature of –40

C and at a minimum

,

C.

o o temperature of –40

C and at a minimum in workshops; for medium mechanical workshop appliances, large boiling installations, heating plates, inspection saws, domestic electric tools, and also temperature of 90 temperature of 90

Suitable for use at maximum conductor

Suitable for use at maximum conductor appliances, soldering irons, toasters). workings etc.

kitchens and offices and for supplying

For general use in domestic premises, for transportable motors or machines on to low mechanical stresses (eg., cooking illumination only.

rubber insulated cables for coil lead.

In dry, humid or moist rooms, in open air

18

1÷25

1÷300

1÷300

1÷25

1.5÷500

0.75÷2.5

0.5÷2.5

1÷240

1÷25

1÷25

1÷185

1.5÷2.5

1.5÷500

4

2÷3

2

1

3

5

4

12÷36

3

2

1

5

4

450/750

300/500

450/750

]

2

[mm sections

Cross

0.75÷400

4

1.5÷2.5

1÷25

1÷185

1÷240

1÷25

1.5÷500

0.75÷1.5

0.75÷1

0.75÷6

0.75÷2.5

0.75÷2.5

0.75÷6

0.75÷2.5

0.75÷2.5

1.5÷2.5

5

4

3

2

1

6÷36

6÷18

1

2÷3

3÷4

2

5

3÷4

2

5

2

1 of cores

Number

300/500

300/500

300/500

300/500

450/750

E, F

A, C, D,

Category

300/500

[V] voltage

Nominal

CABLES IN RUBBER

Standard

82-4

BS 7919

E 02 VD DIN

NF C 32-102-4

82-4

BS 6500

E 02 VD DIN

NF C 32-102-4

82-4

BS 7919

BS 6500

E 02 VD DIN

NF C 32-102-4

82-8 E 02 VD DIN

DIN-VDE 0282-8

5 619 BS

BS 6500, BS 7919

2 82-1 02 VDE DIN

RUBBER INSULATED CABLES

BS 7919

DIN VDE 0282-12

6500

DIN VDE 0282-12BS

BS 7919

BS 6007

H05RNH2-F

Type 4

H05RR-F

H07RN-F

H05BB-F

H07BB-F

H05RN-F

H05RN-F

UK Ref. 638*TQ

H07BN4-F

UK Ref. 318*TQ

H05BN4-F

Designation

Designation

05SN4-F

H07ZZ-F

H07RN8-F

NSHTÖU

NSGAFÖU

NSGAFCÖU

NSSHÖU

NSSHCÖU

R(N)TSCGEWOU

(N)TSCGEWOU

658-FR

0361 TQ

Standard

Nominal voltage

[V]

CABLES IN RUBBER

Number of cores

BS 6500

DIN VDE 0282-12

DIN VDE 0282-13

BS 7919

DIN VDE 0282-16

DIN VDE 0250-814

DIN VDE 0250-602

DIN VDE 0250-812

DIN VDE 0250-813

BS 7917 1999

300/500

450/750

450/750

600/1000

0,6/1 kV

1,8/3 kV

3,6/6 kV

600/1000

3,6/6 kV

÷18/30kV

150/250

600/1000

Cross sections

[mm 2 ]

Application

2÷3

4

1

2

3÷4

4

5

7

5

6÷36

6÷18

3

4

1

2

3÷4

5

7÷18

1

1

2

3÷4

5

6÷7

8÷12

3

0.5÷2.5

0.75÷2.5

1.5÷500

1÷25

1÷185

1÷185

1÷25

1.5÷2.5

1.5÷500

1÷25

1÷240

1÷185

1÷25

1.5÷2.5

4

1.5÷150

70

1.5÷4

1.5÷400

1.5÷400

1.5÷120

1÷185

1.5÷70

1.5÷50

1.5÷4

25+3x25/3

÷3x185

+3x95/3

Silicone rubber insulated and CPE sheathed flexible cords are especially recommended for use in installation of recessed luminaires, lighting fittings where conductor insulation is exposed to high ambient temperature, UV and infra red radiation, where heat dissipation is inhibited.

For indoor and temporary outdoor, particularly for situations in which low emission of smoke and corrosive gases is required in the case of burning. The defined tests for smoke and corrosive gases relate only to the cables, and not to cable and conduit together.

These cables are ideal for the connection of submersible motor pumps for construction site drainage down to a water depth of about 10 m and a maximum water temperature up to 40 o C. They are able to withstand medium mechanical stresses and can also be permanently laid, e.g. on walls, floors, machinery and towers. Unsuitable for under-water power transmission or installation in a waterway.

Trailing cables used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional stress, for building machinery, conveyors, shifts and cranes.

Special rubber insulated cable especially suitable as short-circuit rating in rail-coaches and buses, as well as in day rooms. In switching systems and distribu-tors, these cables are considered to be short-circuit up to 1000V and earth-fault safe.

Rubber insulated flexible cables with or without protective conductors for the connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining, and at quarries and building sites.

For the connection of large mobile equipment such excavators and spreaders for surface mining and for installation along conveyor systems with very high mechanical stress.

1 PR÷10

PR

2c÷27 cores

0.75

÷1.5

1.5÷16.0

For electrical and electronic equipment of ships. Flame retardant.

BS 638 1996 300 1c 16.0

÷240

For use between the welding equipment and the hand electrode

H07BN4-F BS 7919 2001 450/750

1c÷5 cores

4.0

÷630

Heavy duty heat resisting flexible cables for use at temperaure of conductor 90 deg C with medium

19

– PVC insulated, PVC sheathed cables for all electrical equipment,

H05VVC4V5-K – screened oil resistant

H05VV5-F – unscreened and protection against mechanical damage installation, power stations and in data for use as a data and control cables in as a signal cable for electronics.

measurement and control sectors.

Control and signal cables in all areas pair and collective screen) or without screens and optionally incorporating of communication services and the ype 1 unarmoured

Multicore and multipair PVC insulated individual pair and collective screen) or of communication services and the cables 2 armoured Type are suitable for burial underground.

indoor applications.

Type 1 unarmoured cables are generally for process plant. The cables used mainly by the chemical and petrochemical industry. interconnection of electrical equipment’s single wire armour, used in the provision and instruments, particularly in and around without screens and optionally incorporating cables with screens (with collective or with burial underground.

the petroleum industry. T cables are generally for indoor applications. and instruments, particularly in and around interconnection of electrical equipment’s screens (with collective or with individual

Multipair polyethylene insulated cables with apparatus.

transfer such as computers and control requiring lowest possible measurement industries as well as electronic, computer, such areas as tool making and machine

Flexible PVC cables apply especially to without reducing flexibility.

galvanized steel wires offers best possible

Control cables in tool machinery, plant continual flexing.

and on production lines. The cables are industries and as well as in conveyor belts are not designed for continuous immersion cables in the machinery and tool-making cables are used as control and junction tool engineering, plant construction etc.

especially in industrial areas, in machines

Use as measuring, control and connection copper-screened flexible control cables.

flexible control cables.

resistant to general-purpose mineral oils but in oil. Screened cables are not designed for

Application pairs

1÷50

1÷40 core

17

Designation Standard

Nominal voltage

[V]

Number of cores

WELDING CABLES (see also on page 28)

Cross sections

[mm 2 ]

Application

H01N2-D

DIN VDE 0282-6

NF C 32-510

BS 638

100/100 1 10÷185

For use between the welding generator and the hand electrode and the workpiece, in the automobile industry in shipbuilding, in transport and conveyor systems, tool making machinery, welding robots etc.

H01N2-E

SID

RUBBER, HEAT RESISTING SINGLE CORE NON-SHEATHED CABLES

1 0.5÷6

Refer to individual product descriptions

300/500

SIF

H05S-U

H05S-K

DIN VDE 0282-3

BS 6007

NF-C 32-102-3

300/500

1

1

0.25÷120

Single core silicone insulated cables for use in situations, where heat or the interaction of extremely high and low temperatures rapidly causes cable insulation to become brittle and inflexible. In normal use the maximum permissible conductor temperature is 180°C.

0.5÷2.5

RUBBER, HEAT RESISTING SHEATHED CABLES

SIHF

H05SS-F

Adapted to DIN VDE

0250-816

BS 7919

300/500

300/500

2÷5

2

3÷4

5

0.5÷16

0.75÷2.5

0.75÷4

0.75÷2.5

Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant up to 180°C, for short time operation up to 250°C. These cables have become an essential element in a wide range of industrial sectors, including foundries, steel and hot-rolling mills, cooking plants, in electric motor, ship and aircraft construction, on extruders, in heating and lighting systems, bakery machinery, oil burners, solaria and in many other areas.

H05BQ-F

05BQ-F

H07BQ-F

07BQ-F

PUR - SHEATHED CABLES

2÷5

DIN VDE 0282-10

BS 7919

300/500

6÷24

DIN VDE 0282-10

BS 7919

450/750

2÷5

7÷24

0.75÷1

0.75÷1

1.5÷16

PUR-sheathed flexible cables are used for high mechanical stress, especially for scouring and dragging stress, for use in dry, damp and wet places as well for performance in open air and also for the connection of electronic tools and lights on construction sites or in agricultural plants.

Suitable for fixed installation on the surface of plaster, housing, provisional buildings, on machines cranes etc.

1.5÷2.5

NYMH11YÖ DIN VDE 0250-407 300/500 2÷5 0.75÷2.5

PVC insulated and PUR sheathed flexible cables for power installation.

20

32

Aluminium alloy conductors steel-reinforced

Aluminium conductors steel-reinforced for overhead power transmission.

for overhead power transmission.

for overhead power transmission.

All aluminium alloy conductor for overhead power transmission.

Copper stranded conductor for overhead power transmission.

All aluminium conductor

For overhead networks

For overhead networks

Application

Delivery

1400 or 2000 kg

Wooden drums

1400 kg

Wooden drums

30÷100

80÷150

Wooden drums 16÷1000

Wooden drums 10÷1000

Wooden drums 10÷500

Wooden drums 100 16÷1

Wooden drums 100 16÷1

GOST 2584

DIN 43141/2-Ru

ASTM B-47

BS 23

UIC 870

GOST 2584

DIN 43141/1-RiS

EN 50149

DIN 43141/1-Ri

DIN 48201/6

EN 50182

IEC 61089

ASTM B-399

GOST 839

BS 215/1

IEC 61089

DIN 48201/5

EN 50182

GOST 839

BS 7884

ASTM B-8

DIN 48201/1

ASTM B-231

BS 215/2

DIN 48204

EN 50182

IEC 61089

GOST 839

ASTM B-232

ZN-96/MP-13-

K12 208.02

ZN-KFK-021:2000

DIN 48206

EN 50182

[mm]

Dimensions

Standard

COPPER AND COPPER ALLOY GROOVED CONTACT WIRES

BARE CONDUCTORS FOR OVERHEAD POWER TRANSMISSION

AAL

AAAC

AFL

ACSR

AAC stranded

Copper conductors

AACSR contact wire

Grooved wires contact

Round

Designation

Designation

DLO

RHW

RHW-2

RHW-2/LS

RHW-2/USE2

Type W

Type W Flat

Type G

Type G Flat

G-GC

G-GC Flat

SHD-GC

JUMPER CABLE

MV-90

MV-105

URD

(XLPE)

Standard

Nominal voltage

[V]

Number of cores

CABLES ACCORDING TO UL STANDARDS

Cross sections

[mm 2 ]

AAR spec.591

ICEA S-75-381

UL 1581

UL 44

UL 854

CSA-C22.2-96-03

UL 44

ICEA S-75-381

WC 58

2000

2000

1

1, 2, 3

4

5

8AWG÷

500 MCM

8 AWG÷

350 MCM

8÷4/0

AWG

Application

14÷1111

MCM

Diesel Locomotive Cable is an excellent choice as a portable power cable for drilling rigs, on-shore or offshore, diesel-electric locomotives, railroad and transit car wiring.

It is also recommended for electric earthmoving equipment, in shipyard applications, arc welder supply leads, power and control jumper cable, case wire and motor leads.

For use in heavy duty service as power supply cable, AC systems, mobile and portable electrical equipment, mining equipment and motor and battery leads.

6 8÷1AWG

ICEA S-75-381

WC 58

CSA-C22.2-96-03

ICEA S-75-381

WC 58

2000

2000

2÷4

2÷3

4

5

6÷4/0

AWG

8AWG

÷500MCM

8AWG

÷350MCM

6÷1 AWG

For use in heavy duty service as power supply AC systems mobile and portable electrical equipment.

For use in mining machines, locomotives, power supply lead on AC welders, motor and generator leads and grounding cable.

ICEA S-75-381

WC 58

CSA-C22.2-96-03

ICEA S-75-381

WC 58

ICEA S-75-381

WC 58

ICEA S-7538/WC58

CSA-C22.2-96-03

ICEA S-75-381

WC 58

UL 1072

NEMA WC 7

ICEA S-66-524

AEIC CS8

2000 up to 2 kV up to 5 kV up to 8 kV up to

15 kV up to

25 kV

5/15 kV

15 kV

5 kV/8 kV

5 up to

15 kV

25 up to

35 kV

2

3

6÷4/0

AWG

8AWG

÷500

MCM

3

3 phase conductors, earth,

1 control earth core

1

1

1 or

Triplex

6÷4/0

AWG

10 AWG

÷400

MCM

6 AWG

÷350

MCM

4 AWG

÷250

MCM

2 AWG

÷3/0

AWG

1 AWG

2AWG

÷500

MCM

6AWG

÷100MCM

2AWG ÷

1000

MCM

1/0 AWG ÷

1000

MCM

For use with portable electric equipment,

AC mining machines, loaders, drill, cutting machines, and other portable and mobile equipment where self-containing grounding conductor as well as continuous ground monitoring conductor is required.

Mining multi-core cables with earth core for flexible mining supply.

Portable cable for use as a flexible power lead for temporary connections.

For distribution circuits and for feeders or branch circuits.

Medium voltage suitable for Primary

Underground Distribution System; buried directly or installed in underground ducts or conduits or exposed to sunlight for above ground application. Rated for continuous operation at 90ºC conductor temperature.

29