VEHICLE LOOP DETECTOR CONTENTS MODEL# 302-41624-1 302-41624-2 302-416115-1 302-416115-2 DESCRIPTION 24Vac, single detector 24Vac, dual detector 115Vac, single detector 115Vac, dual detector To prevent possible SERIOUS INJURY or DEATH, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. Operator may start automatically when power is applied. APPLICATION WIRE CONNECTIONS This product is intended for use with commercial door and gate operators. Your kit includes either one or two detectors enclosed in an indoor/outdoor rated enclosure wired to the terminal block for field connections. We recommend the the detector be used as an open or safety/hold open only device when a vehicle passes over an embedded loop wire installed in the ground connected to the detector (loop sold separately). Requires two-wire output connection to operator and either 115 Vac or 24 Vac to power the detectors (see label). 1. Disconnect power: All electrical connections must be by a qualified individual. 2. Power Wiring: Connect the proper voltage to terminals L1 and L2 in your loop enclosure. 3. Loop Wiring: Connect embedded loop wires to terminals 4 and 5 if single and the second embedded loop to terminals 9 and 10 if double. 4. Relay Contacts (to operator): Terminal location in the operator will vary by model, refer to the field wiring diagram supplied with your operator. If your field wiring diagram is missing, please contact the provider of your operator. Connect terminals 1, 2 and 3 in field wiring diagram for the first loop and terminals 6, 7 and 8 for the second loop if provided. 5. Reconnect Power to Operator and Detector: IMPORTANT NOTE: Operator may start automatically when power is applied. Refer to the manufactures loop detector instructions for detector set up. Verify intended functions are working as set up for your application. Be sure the door path is clear of obstructions while testing. Replace cover. ENCLOSURE MOUNTING 1. Disconnect power to operator. Do not reapply power until instructed to. All electrical connections must be made by a qualified individual. 2. To mount the enclosure remove the four screws fastening the detector panel to the enclosure. There are four knockouts provided in the bottom of the enclosure for mounting. 3. Mount the enclosure with hardware appropriate to your job conditions. Ensure that you maintain watertight integrity. 4. After the enclosure has been installed remount the detector panel within the enclosure. 01-10004C © 2007, The Chamberlain Group, Inc. All Rights Reserved