ScreenID HRAM ™ Mass accuracy for compound screening to unknown ID 87.0809 100 90 80 97.0764 83.0608 70 338.3411 Relative Abundance 60 177.0544 50 73.0654 40 114.0915 134.0712 171.1489 30 195.1854 NH2 223.0961 226.9511 20 333.1034 149.0232 339.3445 360.3228 230.2475 10 279.1586 361.3263 391.2835 312.3255 256.9615 430.9132 455.2895 392.2748 456.2928 0 0 100 150 200 250 300 350 400 450 500 m/z Close your uncertainty gap with HRAM (high-resolution accurate-mass) spectrometry Today’s forensic toxicology and clinical research laboratory demands more application versatility, data accuracy, and value from the LC-MS systems used for targeted compound screening, quantitation, metabolite identification, as well as the ability to identify true unknown compounds. Confident unknown identification, compound screening, confirmation, and quantification is easier and more affordable than ever before. The value-priced, industry-proven Thermo Scientific™ ScreenID HRAM™ system bundle is built on the Thermo Scientific™ Q Exactive™ Focus hybrid quadrupole-Orbitrap mass spectrometer, Thermo Scientific™ Dionex™ UltiMate™ 3000 RSLC system, and the Thermo Scientific™ High-Resolution Accurate-Mass MS/MS Spectral Libraries. Orbitrap technology Why do you need HRAM? High resolution and mass accuracy are important for improving analytical sensitivity, data selectivity, and accuracy in analysis of biological matrices. Furthermore, high-resolution accurate-mass analytical methods minimize false detection for analytes of interest and improve confidence in identification of known and unknown compounds. Accurate quantitation relies on resolving the compound of interest from complex biological matrix, and high resolving power will make the difference between detecting and not detecting analytes at low concentrations due to the masking effect of isobaric interferences. While Time-of-flight (TOF) technology has also been long used for compound screening and quantitation, can suffer from lower dynamic range, inadequate resolution and mass accuracy (requires a lock mass) and therefore limited selectivity. Limited selectivity results in increased matrix interferences, causing false detection of analytes of interest and inaccurate quantitation. The Screen ID HRAM system bundle includes a proven combination of HRAM mass spectrometer and UHPLC designed to deliver forensic and clinical research application versatility and superior performance. With the combination of stable mass calibration, low maintenance requirements, unmatched flow rate range and simple method development, the ScreenID HRAM system provides a reliable, easy-to-use solution for forensic and clinical research lab work. Acquire answers easily, from analytical method design to data analysis ScreenID HRAM includes two software solutions—Thermo Scientific™ ToxFinder™ easy-to-use data processing software with streamlined workflows for targeted compound screening applications, and Thermo Scientific™ TraceFinder™ software, which provides a flexible workflow-driven method setup with fully automated data acquisition, data processing, and reporting for a wide range of applications including quantitation, targeted and unknown unknown compound screening applications. Maximize productivity - set up forensic and clinical research applications readily To speed deployment, the ScreenID HRAM system bundle includes three days of onsite training (North America only). Identify a broad range of compounds rapidly Identification of a broad range of compounds is faster and more reliable with the High-Resolution Accurate-Mass MS/MS Spectral Libraries. The libraries include multiple spectra of 2500 drugs of abuse, veterinary drugs, therapeutic drugs, environmental toxins and mycotoxins. Ordering Information Item 50000809 726049 222-223900 5200.045 OPTON-30497 OPTON-30239 OPTON-30387 702-027700 Description ScreenID HRAM System Bundle for Clinical Research and Forensic Toxicology Q Exactive Focus System (includes HESI Probe, Syringe, 6 port valve) PowerVar ABC6000.22 single phase 6 kVa, 230 L-N power conditioner (required in the US) UltiMate 3000 Binary RS/OAS-3300TXRS w/o Detector - 3 drawer cool stack SW, TraceFinder 3.3 SP1 Forensic Toxicology SW, ToxFinder 1.0 SW, TOX HRAM MS/MS Spectral Library 1.0 3-DAY LSMS Training Course at Customer Site (North America Only) Contact us To learn more go to www.thermoscientific/ScreenIDHRAM or contact your local sales representative. ©2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. FL64574 EN 0915S