KILLARK LED DVL Series Class II Utility Light Introduction 9 LED TECHNOLOGY Class II, Div. 1 & 2, Groups E, F, G Class III Class I, Div. 2, Groups A, B, C, D C US Certified - File LR11713 FEA T UR E S - S P E C IF IC A T IO N S DV SERIES LED Introduction Killark ‘DVL’ Series LED fixtures are designed for hazardous locations where suspended metal, carbon (such as coal) and grain dusts create explosive or ignitable mixture with the air. LED Luminaire Features and Standards • Compact in Size with Traditional Industrial Appearance and Suitability • DVL LED Housings can be retrofitted to existing DV Series splice boxes; upgrade from incandescent housing 100 Series components • Long Life - 60,500+ maintenance-free hours to 70% initial lumens • Crisp White Light for Excellent Color Rendering - Chromaticity 5000°K (CCT); 70 CRI • Integral driver - maintains fixture’s compact profile to fit in existing spaces •Instant on - including after power interruption • “World Voltage” 120-277VAC 50/60Hz • Solder-LESS LED Board Connections – Vibration Resistant Compliances • UL-8750 for LED lighting • UL 1598 standard for luminaires • UL-844 Standard for lighting fixtures for hazard- ous locations, Class I, Division 2; Class II, Division 2; Class III, Division 2 • CSA C22.2 no. 137-M1981 electric luminaries for use in hazardous locations Materials • Body and splice box are corrosion resistant copper-free aluminum alloy. Steel guard. • Baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection DVL 100 SERIESj MODEL LAMP HUB PENDANT CEILING WALL Type 100 Included 13Watt 1/2” DVL1330A1G DVL1330X1G DVL1330B1G 3/4” DVL1330A2GDVL1330X2G DVL1330B2G Type 100 Included 16Watt 1/2” DVL1630A1G DVL1630X1G DVL1630B1G 3/4” DVL1630A2GDVL1630X2G DVL1630B2G jFixtures supplied with guard. Substitute ‘n‘ for ‘g‘ for fixture less guard. DVL Series LED Catalog Logic DVL 13 30 A 1 G Series Constant Guard N — No Guard G — Guard Wattage 13 - 13W LED 16 - 16W LED Conduit Entry Size 1 —1/2” 2 —3/4” Voltage 30 - 120-277VAC 50/60 Hz 27 - 12-24VDC input Mounting Style A — Pendant X — Ceiling B — Bracket & Fittings for Wall Mount Dimensions Accessories/Components Bodies DVL 1330 LED 13W DVL 1327 LED 13W DVL 1630 LED 16W DVL 1627 LED 16W Globe Guard DCGE-10DAG-100 Mounts DVA1 DVA2 DVX1 DVX2 DVB1 DVB2 As 100 Series incandescent 1/2” Pendant Mount 3/4” Pendant Mount 1/2” Ceiling Mount 3/4” Ceiling Mount 1/2” Wall Mount 3/4” Wall Mount Pendant Mount DVL THERMAL RATIN GS CAT. NO. DVL1330 DVL1630 DVL1330 DVL1630 AMBIENT WATTS C2D1 EFG C1D2 ABCD SUPPLY WIRE 40OC 13 T3B 40OC16T3B 55OC13 - 55OC16 - DVL Electrical Ratings Same as VSL Series - See page 7 T6 T6 T5 T5 Ceiling Mount 90OC 90OC 90OC 90OC Wall Mount overall dimensions Height = 13.125” (333mm) Outward from wall = 7.4” (188mm) See www.hubbell-killark.com Lighting Software, for latest LED Photometry. What makes Killark LED products GREEN? Available 2Q14 • Improved import/export of CAD files (DWG/DXF/PDF) • Improved luminaire selection with images • Calculations in “Real Time” • User definable obstructions • False Colors to indicate “Relative Brightness” • Backward compatible with V4 project files RETURN to Index More Lumens per Watt • Saves Energy compared to other lighting sources Fixture Type Light Line SourceWattagek VM4L13030jLED 134.71 The Difference Visually & Economically • High Color Rendering for better visibilty and less fixtures DeliveredLumens Photometric Lumensl per Watt Report 15630 116.0 BAL17067 VM4P200jMHP 232 18009 77.6 HK09919U VM1L5030jLED 55.12 5824 105.7 BAL17122 VM1S050jHPS 62.0 3360 54.2 HPK009950 VM1H070jMH 90.0 4536 50.4 HPK009935 VQ1F5230jCFL 64.0 2736 42.8 LSI25349 VaporTight mIncan. 150.0 2699 18.0 ET442841 125W LED Floodlight (128W Actual) Photopic 165 Lux; Spectral 285 Lux * Visually Effective lux 251 * • Saves Significant Maintenance Labor Time and $ (fewer trips for relamping) Hours Life n # Trips Killark LED 60,000 1.0 50HPS 24,000 2.5 70MH, 200MHP 15,000 4.0 52CFL (2 x 26W) 10,000 6.0 150 Incan. 80.0 750 • Lower facility carbon footprint (emissions) by reducing electrician maintenance trips to fixture • Service Trucks: direct diesel or gas emissions • Forklifts, Sissor-lifts, or Cherry Pickers: use utility electricity to charge batteries, or gas • High Color Rendering (5000°Kelvin - CCT; 70 CRI) for better visibilty can reduce the number of fixtures needed. • The US DOE recognizes “Spectrally Enhanced Lighting”, particularly at low light levels, as a method to maintain visual effectiveness using fewer watts, e.g. vs HPS (2100°Kelvin - CCT; 21CRI). o. • Killark LED luminaires use RoHS compliant materials to minimize environmental contamination 250W HPS Floodlight (280W Actual) Photopic 267 Lux; Spectral 152 Lux * Visually Effective lux 169 * * Measurements using special Solar Color Sensing Light Meter. Visually Effective Lux indicates a blend of color that can be seen by the human eye. 10 Lux equals approximately 1 Footcandle NOTES: j VM1 Using VMG17 standard globe; VM4 using VMG25 globe (Class I Division 2; Class II Division 1) k Wattage from Test Report or Ballast mfg. data (greater than “nominal” wattage) l Delivered Lumens on LED from Absolute Photometry; for HID, Compact Fluorescent, or Incandescent data is from noted Photometric Report’s Zonal Lumen Summary, which is delivered lumens. m Traditional 3.18” dia. 6.68” high Clear Globe with 150A21 Lamp n Minimum LED Life to 70% of initial lumen ouput; HID, CFL, Incandescent from mfg. catalog data o For more information go to: http://apps1.eere.energy.gov/buildings/publications/pdfs/ssl/lieel_enhanced_longbeach2013.pdf See www.hubbell-killark.com Lighting Software, for latest LED Photometry.