INSTALLATION INSTRUCTIONS 1. REMOVE (4) TEMPORARY SCREWS AND CARDBOARD J-BOX COVER FROM THE BACK-BOX (DO NOT DISCARD). 2. POSITION AND SECURE BACK-BOX TO DESIRE LOCATION (MAKE SURE THE FLANGE PERTRUDE OUTSIDE OF WALL). 3. CONNECT CONDUIT TO J-BOX AND MAKE PROPER WIRE CONNECTIONS (CONDUIT AND CONNECTORS BY OTHERS). 4. RE-INSTALL THE CARDBOARD COVER TO THE BACK-BOX AS IT ORIGINALLY WAS. (2) RUBBER PLUGS 5. POUR CONCRETE. SEE FIGURE "A" AND FIGURE "B" FOR MORE DETAILS. 11.125 (REF) BACK-BOX TEMPORARY CARDBOARD COVER (4) TEMPORARY SCREWS 11.875 (REF) LEVEL OF FINISH ON CEILING FIGURE "A" 5.56 (REF) 4.39 (REF) 3.69 SQ. (REF) FINISHED WALL 1.41 (REF) 10.875 (REF) FRONT VIEW BACK-BOX WITH J-BOX 10.125 (REF) FIGURE "B" CATALOG NUMBER MDL - RJM MOLDCAST 14249 Artesia Blvd. P.O. Box 1869 La Mirada CA. 90638-1869 714-994-2700 Fax 714-994-0522 PART N0. A96315 DATE APPRVD DATE REV 03/14/08 B INSTALLATION INSTRUCTIONS 1. REMOVE (4) TEMPORARY SCREWS AND CARDBOARD BACK-BOX COVER FROM THE BACK-BOX (DO NOT DISCARD). 2. POSITION AND SECURE BACK-BOX TO DESIRE LOCATION (MAKE SURE THE FLANGE PERTRUDE OUTSIDE OF WALL). 3. CONNECT CONDUIT TO HOUSING AND MAKE PROPER WIRE CONNECTIONS (CONDUIT AND CONNECTORS BY OTHERS). 4. RE-INSTALL THE CARDBOARD COVER TO THE BACK-BOX AS IT ORIGINALLY WAS. (2) RUBBER PLUGS 5. POUR CONCRETE. SEE FIGURE "A" AND FIGURE "B" FOR MORE DETAILS. CONDUIT (BY OTHERS) NOTE: SHOWN ONE SIDE ONLY. THREADED PLUG ON ONE SIDE ONLY NOTE: CONDUIT ENTRY DRILL AND TAP FOR 1/2-14 NPSM. 11.125 (REF) TEMPORARY CARDBOARD COVER (4) TEMPORARY SCREWS 5.56 (REF) .75 11.875 (REF) FIGURE "A" LEVEL OF FINISH ON CEILING FINISHED WALL 2.812 10.875 (REF) 10.125 (REF) FRONT VIEW BACK-BOX FIGURE "B" CATALOG NUMBER MDL - RDE MOLDCAST 14249 Artesia Blvd. P.O. Box 1869 La Mirada CA. 90638-1869 714-994-2700 Fax 714-994-0522 PART N0. A96341 DATE APPRVD DATE REV 03/14/08 A