Revised and Corrected • September 1, 2009 Catalog No. F-62 Cabinets • Racks & Reels • Fire Hose • Nozzles • Adapters • Standpipe Brass • Testing Equipment • Specialties • Accessories 18436 Bandilier Circle • Fountain Valley, California 92708 Toll Free 888.773.3473 • Fax Toll Free 888.713.3473 Internet: www.gmr-fire.com Introduction Corporate offices and distribution center Fountain Valley, California GMR Fire Protection is a dynamic, energetic company established in 1990 to serve the fire equipment needs of the construction industry. GMR cabinets, hose racks, and related products can be found in office buildings, hotels, warehouses, hospitals, oil refineries, and many other facilities around the world. The fire protection industry has seen many changes in recent years, and we have kept pace with those changes. Architects, engineers, distributors, contractors, and building owners know they can depend on us for: • High quality products manufactured in modern, automated plants • Short, dependable lead times • Compliance with recognized industry standards including Underwriters Laboratories (UL) and Factory Mutual (FM) • Knowledgeable personnel with years of fire protection expertise • Flexibility in responding to customer needs We hope you find this catalog a useful tool for specifying or purchasing interior and industrial fire products. If you need application assistance, we invite you to contact one of our product specialists...help is just a phone call, fax, or mouse click away. i Index Catalog No. F-62 Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 1 thru 11 Cabinet Selection Guide . . . . . Fire Hose Cabinets . . . . . . . . . Fire Extinguisher Cabinets . . . Hose Valve Cabinets . . . . . . . Outdoor Cabinets . . . . . . . . . . Misc. Cabinets & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 1 2–3 4–8 ... 9 . . 10 . . 11 Hose & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 12 thru 27 Hose Rack Units . . . . . . . . . . . . . . Hose Rack Options & Accessories Hose Reels & Accessories . . . . . . Misc. Hose Storage Devices . . . . Fire Hose & Couplings . . . . . . . . . Nozzles & Shutoffs . . . . . . . . . . . . Hose Adapters . . . . . . . . . . . . . . . .. . .. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... .... 14 – .... 19 – 21 – 24 – 12 13 17 18 20 23 27 Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 28 thru 32 Angle Hose Valves . . . . . . . Hose Gate Valves . . . . . . . Misc. Hose Valves . . . . . . . Globe & Angle Valves . . . . . Check Valves . . . . . . . . . . . Ball Valves . . . . . . . . . . . . . Misc. Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 29 30 31 31 31 32 Fire Department Connections . . . . . . . . . . . . . . . . . . . Pages 33 thru 39 Exposed Type w/ Clapper Inlets . Exposed Type w/ Single Clapper Exposed Type – Complete Units Free Standing Type . . . . . . . . . . Flush Type . . . . . . . . . . . . . . . . . Pump Test Connections . . . . . . . Wall Hydrants . . . . . . . . . . . . . . . Roof Manifolds . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 – .... .... .... .... .... .... .... .... 34 34 35 35 36 37 37 38 39 Index Sprinkler Accessories & Testing Equipment . . . . . . . Pages 40 thru 44 Sprinkler Accessories . . . . . . . . Signs . . . . . . . . . . . . . . . . . . . . . Testing Equipment . . . . . . . . . . Fire Alarm Bells & Accessories Flow & Supervisory Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... .... 41 – .... .... 40 41 43 43 44 Specialties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 45 thru 57 Station Monitors . . . . . . . Portable Monitors . . . . . . Master Stream Nozzles . Monitor Accessories . . . . Fire Hydrant Accessories Hose Houses . . . . . . . . . Hydrant Houses . . . . . . . Roof House . . . . . . . . . . Carts & Trailers . . . . . . . Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 – .... .... .... .... .... .... .... .... 55 – 46 47 48 49 50 51 52 53 54 57 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages A1 thru A15 Important Notice: Contact GMR for current listings and approvals. Dimensions are subject to manufacturer’s tolerance and may change without notice. We assume no responsibility for use of obsolete or invalid data. GMR Fire Protection 18436 Bandilier Circle • Fountain Valley, CA 92708 Toll Free 888.773.3473 • Local & International 714.968.0105 Fax Toll Free 888.713.3473 • Local & International Fax 714.968.0159 Internet: www.gmr-fire.com © 2006 – 2009 by GMR International Equipment Corporation. All rights reserved. This publication may not be reproduced either in part or in whole without the express written permission of the copyright holder. iii Cabinet Selection Guide Construction Features Variations & Accessories Our cabinets are built using high quality raw materials and skilled workmanship to provide lasting durability. Precision manufacturing ensures dimensional stability and superior fit and finish. Numerous cabinet variations and accessories are available, including: • Special paint finishes • Plaques or nameplates Box: 22 gauge cold rolled steel with reinforced corners. Heavier gauges by special order. • Hose holders • Weatherproofing Door & Trim: 20 gauge door and 18 gauge trim with full length continuous steel hinge with brass pin. Constructed of cold rolled steel, formed, mitered, welded, and ground smooth. • Ventilation louvers • Duplex construction • Alarm switches Finish: Powder coated with an electrostatically applied, thermally fused white polyester finish. • Special locks Optional Materials Fire Rated Option Provides cabinet manufactured in accordance with Warnock Hersey certified designs and labeled for 1 and 2 hour combustible and noncombustible walls. Box has double wall construction, lined with fire resistant material. Available on most cabinets. Stainless Steel: Constructed same as steel using 304 stainless steel with #4 brushed finish. To specify, add prefix SS- to cabinet figure number. Aluminum: Extruded door and trim with clear anodized finish to prevent oxidation and corrosion. To specify, add prefix AL- to cabinet figure number. Custom Built Cabinets We have the ability to design and fabricate cabinets to meet your special requirements. Cabinets can be built in both standard and nonstandard sizes, with any number of custom features including extra heavy gauge material, equipment brackets, special doors, etc. etc. etc. Door Styles Style Suffix Full Clear .06" Acrylic Full Wire Glass Break Glass w/ Safety Lock FG FW BL Horizontal Duo Panel Vertical Duo Panel Solid Panel DP DV SP Please provide drawings and/or specifications. All of the above except break glass (-BL) are furnished with a pull handle and self-adjusting friction catch. Break glass doors are furnished with a keyed-alike cylinder lock with break-off tab. All door styles except horizontal duo panel (-DP) are reversible and may be installed with hinge to either left hand or right hand side. 1 Fire Hose Cabinets Provides storage for a 1½” or 2½” x 1½” hose rack unit • 22 gauge steel box • 20 gauge door with continuous hinge and brass pin • 18 gauge trim • White polyester powder coat finish inside & out Optional Materials: Stainless steel or aluminum door & trim. Fire Rated Option: Provides cabinet manufactured in accordance with Warnock Hersey certified designs and labeled for 1 and 2 hour combustible and non-combustible walls. Box has double wall construction, lined with fire resistant material. Cabinet Capacities Series Hose Rack Unit Fire Extg. 2½” Hose Valve 14100 14200 14300 50' or 75' 100' 100' — — — — — U 14400 14500 14600 50' or 75' 100' 100' U U U — — U To Order: 1. Refer to cabinet capacity table above to select cabinet series. Select cabinet by Fig. No. Select door style by suffix (see Cabinet Selection Guide on page 1). Select optional door & trim material and/or fire rated option, if required. Order cabinet contents separately. 2. 3. 4. 5. Note: The 14100, 14200, and 14300 series cabinets will accommodate a 5 lb. dry chemical fire extinguisher when required. 2 Fire Hose Cabinets Box i.d. Fig. No. Frame o.d. Wall Opening Knockouts Trim Style A B C E F W H D J G J G 14101 14102 14103 14104 14106 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 24" 24" 24" 24" 27d” 30" 30" 30" 30" 33d” 8" 8" 8" 8" 8½” 27d” 23¾” 27d” 27d” — 33d” 29¾” 33d” 33d” — 25" 24½” 25" 25" — 31" 30½” 31" 31" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — 14201 14202 14203 14204 14206 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 24" 24" 24" 24" 27d” 34¾” 34¾” 34¾” 34¾” 38c” 8" 8" 8" 8" 8½” 27d” 23¾” 27d” 27d” — 38c” 34½” 38c” 38c” — 25" 24½” 25" 25" — 36" 35¼” 36" 36" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — 14301 14302 14303 14304 14306 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 24" 24" 24" 24" 27d” 38¾” 38¾” 38¾” 38¾” 42c” 8" 8" 8" 8" 8½” 27d” 23¾” 27d” 27d” — 42c” 38½” 42c” 42c” — 25" 24½” 25" 25" — 40" 39¼” 40" 40" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — 14401 14402 14403 14404 14406 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 30" 30" 30" 30" 33d” 30" 30" 30" 30" 33d” 8" 8" 8" 8" 8½” 33d” 29¾” 33d” 33d” — 33d” 29¾” 33d” 33d” — 31" 30½” 31" 31" — 31" 30½” 31" 31" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — 14501 14502 14503 14504 14506 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 32¾” 32¾” 32¾” 32¾” 36c” 34¾” 34¾” 34¾” 34¾” 38c” 8" 8" 8" 8" 8½” 36c” 32½” 36c” 36c” — 38c” 34½” 38c” 38c” — 34" 33¼” 34" 34" — 36" 35¼” 36" 36" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — 14601 14602 14603 14604 14606 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 32¾” 32¾” 32¾” 32¾” 36c” 38¾” 38¾” 38¾” 38¾” 42c” 8" 8" 8" 8" 8½” 36c” 32½” 36c” 36c” — 42c” 38½” 42c” 42c” — 34" 33¼” 34" 34" — 40" 39¼” 40" 40" — 8" 8½” 6¾” 5½” — 4" 4" 4" 4" — 4" 4" 4" 4" — 2½” 4" 2½” 2½” — 4" 4" 4" 4" — NOTES: 1. 2. 3. 4. 5. 6" deep box available on 14100, 14200, and 14400 series. For aluminum cabinets with 2½” semi-recessed trim, add e” to wall opening depth. Cabinets with trim projection of 2½” or less comply with American with Disabilities Act (ADA) of 1990 requirements. Contact GMR for suggested wall opening measurements for fire rated cabinets. Knockouts are not provided on fire rated cabinets. The installer is responsible for the location and size of the cut-out required for supply piping into cabinet. Installation instructions are provided and must be followed exactly to maintain the cabinet’s fire rating. 3 Fire Extinguisher Cabinets Architectural Style Provides storage for one or two hand portable fire extinguishers • 22 gauge steel box • 20 gauge door with continuous hinge and brass pin • 18 gauge trim • White polyester powder coat finish inside & out. Optional Materials: Stainless steel or aluminum door & trim. Fire Rated Option: Provides cabinet manufactured in accordance with Warnock Hersey certified designs and labeled for 1 and 2 hour combustible and non-combustible walls. Box has double wall construction, lined with fire resistant material. Cabinet Capacities Series For Use With (Max. Extinguisher Size) 13130 2½ or 5 lb. Dry Chemical Fire Extinguisher 13200 10 lb. Dry Chemical Fire Extinguisher 13210 20 lb. Dry Chemical, 10 lb. CO2, or 2½ Gal. Pressurized Water Fire Extinguisher 13220 20 lb. Dry Chemical, 15 lb. CO2, or 2½ Gal. Pressurized Water Fire Extinguisher 13230 Two (2) 20 lb. Dry Chemical, 10 lb. CO2, or 2½ Gal. Pressurized Water Fire Extinguishers To Order: 1. 2. 3. 4. 5. Refer to cabinet capacity table above to select cabinet series. Select cabinet by Fig. No. Select door style by suffix (see Cabinet Selection Guide on page 1). Select optional door & trim material and/or fire rated option, if required. Fire extinguishers are purchased separately. 4 Fire Extinguisher Cabinets Box i.d. Fig. No. Frame o.d. Wall Opening Trim Style A B C E F W H D 13131 13132 13133 13134* 13136 Recessed Trimless Semi-Rec 1½ Semi-Rec 2½ Surface 9" 9" 9" 9" 12d” 18" 18" 18" 18" 21d” 5½” 5½” 5½” 5½” 6” 12d” 9¼” 12d” 12d” — 21d” 18¼” 21d” 21d” — 10" 10" 10" 10" — 19" 19" 19" 19" — 5½” 5¾” 4" 3c” — 13201 13202 13203 13204* 13205* 13206 Recessed Trimless Semi-Rec 1½ Semi-Rec 3 Semi-Rec 4½ Surface 10½” 10½” 10½” 10½” 10½” 13f” 24" 24" 24" 24" 24" 27d” 6" 6" 6" 6" 6" 6½” 13f” 10¾” 13f” 13f" 13f” — 27d” 24¼” 27d” 27d” 27d” — 11½” 11" 11½” 11½” 11½” — 25" 24½” 25" 25" 25" — 6" 6¼” 4½” 3e” 1e” — 13211 13212 13213 13214* 13215* 13216 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Semi-Rec 4½ Surface 12" 12" 12" 12" 12" 15d” 27" 27" 27" 27" 27" 30d” 7¾” 7¾” 7¾” 7¾” 7¾” 8½” 15d” 12¼” 15d” 15d” 15d” — 30d” 27¼” 30d” 30d” 30d” — 13" 12½” 13" 13" 13" — 28" 27½” 28" 28" 28" — 7f” 8¼” 6¾” 5½” 3½” — 13221 13223 13224* 13225* 13226 Recessed Semi-Rec 1¼ Semi-Rec 2½ Semi-Rec 4½ Surface 16" 16" 16" 16" 19d” 32" 32" 32" 32" 35d” 7¾” 7¾” 7¾” 7¾” 8½” 19d” 19d” 19d” 19d” — 35d” 35d” 35d” 35d” — 17" 17" 17" 17" — 33" 33" 33" 33" — 7f” 6¾” 5½” 3½” — 13231 13233 13234* 13235* 13236 Recessed Semi-Rec 1¼ Semi-Rec 2½ Semi-Rec 4½ Surface 20" 20" 20" 20" 23d” 27" 27" 27" 27" 30d” 7¾” 7¾” 7¾” 7¾” 8½” 23d” 23d” 23d” 23d” — 30d” 30d” 30d” 30d” — 21" 21" 21" 21" — 28" 28" 28" 28" — 7f” 6¾” 5½” 3½” — NOTES: 1. 2. 3. For cabinets indicated by an asterisk (*), add e” to “D” dimension when furnished with an aluminum door & trim. Cabinets with trim projection of 2½” or less comply with Americans with Disabilities Act (ADA) of 1990 requirements. Contact GMR for suggested wall opening measurements for fire rated cabinets. 5 Fire Extinguisher Cabinets Canopy Style Provides storage for one or two portable fire extinguishers • Bubble-type canopy increases visibility of cabinet for quick identification of fire extinguisher • 22 gauge steel box • 20 gauge door & trim with continuous hinge and brass pin • Vacuum-formed acrylic canopy • White polyester powder coat finish inside & out Optional Materials: Stainless steel or aluminum door & trim. Fire Rated Option: Provides cabinet manufactured in accordance with Warnock Hersey certified designs and labeled for 1 and 2 hour combustible and non-combustible walls. Box has double wall construction, lined with fire resistant material. Cabinet Capacities Series For Use With (Max. Extinguisher Size) 13300 10 lb. Dry Chemical Fire Extinguisher 13310 20 lb. Dry Chemical Fire Extinguisher 13320 Two (2) 20 lb. Dry Chemical Fire Extinguishers To Order: 1. 2. 3. Select cabinet by Fig. No. Select canopy color: Clear, red or bronze Select optional material and/or fire rated option, if required. Fire extinguishers are purchased separately. 4. Box i.d. Fig. No. 13301 13303 13304 13306 Frame o.d. Wall Opening Trim Style Recessed Semi-Rec 1½ Semi-Rec 3 Surface A B C E F W H D 10½” 10½” 10½” 13f” 24" 24" 24" 27f” 4" 4" 4" 4e” 13f” 13f” 13" — 27d” 27d” 26½” — 11½” 11½” 11½” — 25" 25" 25" — 4" 2e” 1e” — (Continued on page 7) 6 Fire Extinguisher Cabinets Box i.d. Fig. No. Frame o.d. Wall Opening Trim Style A B C E F W H D 13311 13313 13314 13316 Recessed Semi-Rec 1¼ Semi-Rec 2½ Surface 14" 14" 14 17d” 30" 30" 30" 33d” 4" 4" 4" 4e” 17d” 17d” 17d” — 33d” 33d” 33d” — 15" 15" 15" — 31" 31" 31" — 4" 2f” 1e” — 13321 13326 Recessed Surface 28" 31d” 30" 33d” 4" 4e” 31d” — 33d” — 29" — 31" — 4" — NOTES: 1. 2. Cabinets with trim projection of 2½” or less comply with Americans with Disabilities Act (ADA) of 1990 requirements. Contact GMR for suggested wall opening measurements for fire-rated cabinets. Corner Style Provides storage for a single hand portable fire extinguisher • Triangular shape allows cabinet to be mounted in corner locations • Complies with Americans with Disabilities Act (ADA) of 1990 • 18 gauge steel box • 20 gauge door with continuous hinge with brass pin • White polyester powder coat finish inside & out Optional Materials: Stainless steel or aluminum construction. To Order: 1. 2. 3. 4. Select cabinet by Fig. No. Select door style by suffix. Select optional material by prefix, if required. Fire extinguishers are purchased separately. Dimensions Fig. No. Trim Style For Use With (Max. Extinguisher Size) W H D 13401 Surface 15¾” 18" 8c” 5 lb. Dry Chemical Fire Extinguisher 13402 Surface 15¾” 24" 8c” 10 lb. Dry Chemical Fire Extinguisher 7 Fire Extinguisher Cabinets 13000 Economy Series Provides storage for portable fire extinguisher • Economical means of protecting extinguisher while discouraging tampering or theft • Surface mount construction is suitable for new construction or remodeling • Heavy gauge steel with silver gray hammertone finish • Breakable acrylic panel with retaining clip and padlock hasp • Breaker bar with chain included Optional Material: Aluminum construction with white or red polyester finish. Fig. No. Trim Style 13001 13003 13005 Surface Surface Surface W H D For Use With (Max. Extinguisher Size) 8c” 9c” 10c” 18" 24" 28" 5½” 5½” 8¼” 2½ or 5 lb. Dry Chemical 10 lb. Dry Chemical or 5 lb. CO2 2½ Gal. Pressurized Water or 15 lb. CO2 13100 Economy Series Provides storage for portable fire extinguisher • Economical means of protecting extinguisher while discouraging tampering or theft • Surface mount construction is suitable for new construction or remodeling • Heavy gauge galvanized steel with white polyester finish • Breakable acrylic panel with retaining clip and padlock hasp • Breaker bar with chain included Optional Material: Aluminum construction with white or red polyester finish. Fig. No. Trim Style 13101 13102 13103 Surface Surface Surface W H D For Use With (Max. Extinguisher Size) 9c” 9½” 10½” 1913/16 " 25¾” 29¾” 6¼” 6¼” 8¼” 2½ or 5 lb. Dry Chemical 10 lb. Dry Chemical or 5 lb. CO2 2½ Gal. Pressurized Water or 15 lb. CO2 Note: Cabinets do not include fire extinguisher, which must be ordered separately. 8 Hose Valve Cabinets Provides storage for a single 2½” fire hose valve • 15200 series is used with pressure reducing valves or in situations where the authority having jurisdiction requires 12" spanner clearance • 22 gauge steel box • 20 gauge door with continuous hinge and brass pin • 18 gauge trim • White polyester powder coat finish inside & out Optional Materials: Stainless steel or aluminum door & trim. Fire Rated Option: Provides cabinet manufactured in accordance with Warnock Hersey certified designs and labeled for 1 and 2 hour combustible and non-combustible walls. Box has double wall construction, lined with fire resistant material. To Order: 1. 2. Select cabinet by Fig. No. Select door style by suffix (see Cabinet Selection Guide on page 1). Select optional door & trim material and/or fire rated option, if required. Order hose valve separately. 3. 4. Box i.d. Fig. No. Frame o.d. Wall Opening Knockouts Trim Style A B C E F W H D J G J G 15101 15102 15103 15104 15106 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 18" 18" 18" 18" 21d” 18" 18" 18" 18" 21d” 8" 8" 8" 8" 8½” 21d” 17¾” 21d” 21d” — 21d” 17¾” 21d” 21d” — 19" 18½” 19" 19" — 19" 18½” 19" 19" — 8¼” 7¾” 6f” 5e” — 4" 4" 4" 4" — 9" 9" 9" 9" — 2½” 4" 2½” 2½” 9" 9" 9" 9" — 15201 15202 15203 15204 15206 Recessed Trimless Semi-Rec 1¼ Semi-Rec 2½ Surface 26" 26" 26" 26" 29d” 26" 26" 26" 26" 29d” 10" 10" 10" 10" 10½” 29d” 25¾” 29d” 29d” — 29d” 25¾” 29d” 29d” — 27" 26"½ 27" 27" — 27" 26½” 27" 27" — 9¾” 10¼” 8f” 7e” — 5" 5" 5" 5" — 13" 13" 13" 13" — 5" 5" 5" 5" — 13" 13" 13" 13" — NOTES: 1. 2. 3. 4. For aluminum cabinets with 2½” semi-recessed trim, add e” to wall opening depth. Cabinets with trim projection of 2½” or less comply with American with Disabilities Act (ADA) of 1990 requirements. Contact GMR for suggested wall opening measurements for fire rated cabinets. Knockouts are not provided on fire rated cabinets. The installer is responsible for the location and size of the cut-out required for supply piping into cabinet. Installation instructions are provided and must be followed exactly to maintain the cabinet’s fire rating. 9 Outdoor Cabinets Fiberglass Hose & Extinguisher Cabinets Provides storage for hose rack unit and/or fire extinguisher • Free standing design is suitable for docks and other areas where wall mounting is not practical • Constructed of sturdy, high visibility optic yellow fiberglass • Break glass style door with stainless steel hinges (Fig. No. 14998) or full breakable glass panel (Fig. No. 19999) • Keyed alike cylinder lock • Also available in red or white Overall Dimensions Fig. No. For Use With 14998 Hose Rack Unit & Fire Extinguisher 14999 Fire Extinguisher Only W H D 32" 48" 8" 12e” 34" 9" Plastic Fire Extinguisher Cabinets Provides storage for a single hand portable fire extinguisher • Non-metallic construction is especially suitable for outdoor locations where corrosion is a problem • Vacuum-formed ABS plastic construction with ultraviolet (UV) inhibitors • Non-metallic hinges and door latch • Rubber gasket door seal • Bright red door with pictogram or decal identifies cabinet and its contents Overall Dimensions Fig. No. For Use With (Max. Extg. Size) W H D 13120 10 lb. Dry Chemical or 5 lb. CO2 14" 21" 9½" 13121 30 lb. Dry Chemical or 20 lb. CO2 21” 32" 13" 10 Misc. Cabinets & Accessories Fire Blanket Cabinets Key Lock Box • Alarm Station Cover Provides added security, discourages tampering • Heavy gauge steel construction • White polyester powder coat finish • Single strength breakable glass panel • Padlock provision (padlock must be ordered separately) For smothering flames or for general first aid use • Cabinet storage keeps blanket clean and ready for use • Blanket complies with NFPA 701 standard for flame retardant textiles and films • 60" x 80" wool blend blanket with flame retardant treatment; will not support combustion • Heavy gauge steel cabinet with red polyester powder coat finish inside and out • Fig. No. 28206 has roller bar and blanket with arm loop Fig. No. 28204 28206 H W D 13" 68" 16" 6½” 4½” 4½” Fig. No. Description HxWxD 16992 16993 Key Lock Box Alarm Station Cover 6" x 4" x 2½” 6" x 6" x 2½” Breaker Bar Steel bar with chain used with break glass style cabinets Fig. No. 78901 . . . . . . . . . . . . . . . . . . . . . . . . . . Breaker Bar Padlock For use on cabinets that have a lock hasp • Keyed alike, two keys provided Fire Axe Cabinet Fig. No. 78111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Padlock Used to store fire axe, discourages tampering • Heavy gauge steel construction • Silver gray hammertone finish • Single strength breakable glass panel • Padlock provision • Overall dimensions 42" x 16" x 4" (W x H x D) • Axe, brackets, and padlock are ordered separately Fire Axe Brackets Used to store fire axe, may be used with Fig. No. 16991 fire axe cabinet • Heavy gauge steel • Red polyester powder coat finish Fig. No. 16991 . . . . . . . . . . . . . . . . . . . . . . Fire Axe Cabinet Fig. No. 69131 . . . . . . . . . . . . . . . . . . . . . . Fire Axe Brackets 11 Hose Rack Units Provides a readily available and effective means of fire control when installed on interior standpipe and hose systems • Semi-automatic operation permits use by a single individual 45100 Series 1½” Hose Rack Units • • • Fig. No. 48301 UL/FM angle valve Fig. No. 45901 hose rack nipple Fig. No. 45100-1 UL/FM semi-automatic hose rack Fig. No. 39501 FM approved rack hose with brass couplings Fig. No. 57104 UL/FM hose rack nozzle • • 45110 Series 2½” x 1½” Hose Rack Units • • • • Fig. No. 48303 UL/FM angle valve Fig. No. 45902 hose rack nipple Fig. No. 43103 reducer Fig. No. 45100-1 UL/FM semi-automatic hose rack Fig. No. 39501 FM approved rack hose with brass couplings Fig. No. 57104 UL/FM hose rack nozzle • • To Order: 1. 2. Select hose rack unit by Fig. No. Select option(s) by suffix, if required (see page 13). Fig. No. Valve Hose A B C D E 45101 45102 45103 1½” 1½” 1½” 50' 75' 100' 1½” 1½” 1½” 17d” 21d” 28" 19e” 19e” 19e” 17¾” 17¾” 17¾” 4¼” 4¼” 4¼” 45111 45112 45113 2½” 2½” 2½” 50' 75' 100' 2c” 2c” 2c” 19" 23" 30" 20d” 20d” 20d” 17¾” 17¾” 17¾” 4¼” 4¼” 4¼” 12 Options & Accessories Hose Rack Unit Options Hose Rack Nipples To select option(s) required, add suffix to basic hose rack unit Fig. No. Supports hose rack from valve and provides male hose thread outlet for attachment of hose • Cast brass • Hexagonal wrench flats • Male NPT x male hose thread outlet • Polished brass and/or chrome plated finish optional Option Suffix Fig. No. 57103 brass fog nozzle Fig. No. 57106 “All Fog” brass nozzle Fig. No. 57152 polycarbonate fog nozzle B E L Polished brass valve & trim, red rack Rough brass valve, polished trim, red rack Rough chrome valve & trim, red rack Polished chrome valve, trim, and rack Fig. No. Size 45901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1½” 45902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2½” PB PT RC PC UL labeled hose U Wall bracket mounting Pipe clamp mounting (specify pipe size) W P Wall Bracket Used to support hose rack independent of standpipe valve • Welded steel with red enamel finish NOTE: When wall bracket mounting (option “W”) is selected, hose units are furnished with F x M angle valve. This option does not require the use of a hose rack nipple. Fig. No. 45911 . . . . . . . . . . . . . . . . . . . . . . . . . . Wall Bracket Semi Automatic Hose Racks Used with Fig. No. 39501 rack & reel hose on interior standpipe systems • Semi-automatic operation • Heavy gauge welded steel cover • Aluminum water retention clip • Cadmium plated movable pins • Spring clip nozzle bracket • Red polyester powder finish • UL listed • FM approved • Polished chrome finish optional • Maximum hose capacity: 100' Fig. No. 45100-1 45100-1R Valve Hose Size 1½” 2½” 1½” 1½” Hose Rack Covers Keeps rack free of dirt and moisture • Nylon reinforced PVC fabric • Bright red for easy identification 13 Fig. No. For Use With 53105 53106 50' or 75' Hose Rack Unit 100' Hose Rack Unit Swinging Hose Reels Standard Duty Reels Provides storage for flat-folding fire hose • Reel automatically swings to proper angle as hose is unreeled • Drum storage eliminates kinking, prolongs hose life • Solid steel rims with rolled edges • 18 gauge steel hubs • 12 gauge steel frame and wall bracket • High strength injection molded drum • Red polyester powder coat finish Hose Reel Options Description Suffix Corrosion resistant finish Pipe clamp mounting (specify pipe size) CR P To Order: 1. 2. 3. Select hose reel by Fig. No. Select option(s) by suffix, if required. Order hose, nozzles, and accessories separately. Hose Capacity Fig. No. 45201 45202 45203 Hose Size 1½” 1½” 2½” Rack & Reel Single Jacket Double Jacket 100' 150' 150' 50' 100' 100' — 50' 50' 14 A B Overall Depth 18" 24" 24" 23½” 29" 33½” 6¼” 6¼” 7f” Swinging Hose Reels Heavy Duty Reels Provides storage for flat-folding fire hose • Reel automatically swings to proper angle as hose is unreeled • Drum storage eliminates kinking, prolongs hose life • ½” o.d. tubular steel rims & frame • Heavy gauge steel spokes • 18 gaueg steel hubs • Two-piece wall bracket • Heavy gauge steel drum • Red enamel finish Hose Reel Options Description Suffix Pipe clamp mounting (specify pipe size) P To Order: 1. 2. 3. Select hose reel by Fig. No. Select optional pipe clamp mounting, if required. Order hose, nozzles, and accessories separately. Hose Capacity Fig. No. Hose Size Rack & Reel Single Jacket Double Jacket A B Overall Depth 45204 45205 45206 1½” 1½” 1½” 75' 100' 150' — 50' 100' — — 50' 16¼” 20e” 26" 24½” 28½” 34½” 7½” 7½” 7½” 45207 45208 45209 2½” 2½” 2½” 100' 150' 250' — 50' 100' — — 50' 20e” 26" 26" 28½” 34½” 34½” 10" 10" 13½” Note: This series of reels is no longer available effective October 1, 2007. This information is provided for reference only. 15 Hose Reel Units • Accessories Hose Reel Units Water Retention Device Provides a readily available and effective means of fire control when installed on interior standpipe and hose systems • Reel automatically swings to proper angle as hose is unreeled • Drum storage eliminates kinking, prolongs hose life Used with 45210 series hose reel unit to provide semi-automatic (oneman) operation • Cast aluminum construction with tension adjustment • Specify rack & reel or single jacket hose when ordering Hose Reel Covers Each complete unit includes: • • • • • Keeps reel free of dirt and moisture • Nylon reinforced PVC fabric • Velcro fasteners • Bright red for easy identification Swinging hose reel F x M angle valve Rack & reel hose Brass hose couplings Nozzle To Order: 1. 2. Fig. No. Fig. No. 45299 . . . . . . . . . . Water Retention Device Select hose reel unit by Fig. No. Options and accessories are ordered separately. Reel Valve Hose Length 45211 45212 45213 45201 1½” 1½” 50' 75' 100' 45214 45215 45216 45201 2½” 1½” 50' 75' 100' 45217 45218 45219 45203 2½” 2½” 50' 75' 100' 16 Fig. No. For Use With Reel Dia. 53108 53109 53110 53111 45201, 45204 45205 45202 45206 16 - 18" 21" 24" 26" 53118 53119 53120 53121 45207 45203 45208 45209 21" 24" 26" 26" Continuous Flow Hose Reels Provides immediate and continuous water flow. Commonly used in special hazards fire protection systems. • • • • • • • • • Electrically welded steel frame Heavy gauge steel drum with internal tie rod reinforcement 1" o.d. tubular steel rims Heavy gauge steel spokes Ductile iron swivel joint Quick-release tension brake assembly 300 PSI rated working pressure Universal mounting stand Red polyester powder coat finish Hose Reel Options Description Suffix Aluminum construction Hot dip galvanized finish Stainless steel construction AL GV SS Brass swivel joint Offset gear crank rewind High stand (specify height) BR HC HS To Order: 1. 2. 3. 4. Select hose reel by Fig. No. Indicate inlet location, i.e. left hand or right hand side. If location is not indicated, right hand inlet will be supplied. Indicate options required, if any. Hose, nozzles, and accessories are ordered separately. Hose Capacity Fig. No. 45301 45302 45303 45304 45306 Inlet NPT 1½" 1½" 1½" 1½” 1½” ¾” 1" 1½” 150' 200' 250' — — 100' 150' 200' 200' 300' 50' 75' 100' 100' 200' A B C D E F G H 28" 22" 28" 25" 28" 29½” 23½” 29½” 26½” 29½” 10" 25" 15" 20" 25" 11" 11" 11" 11" 11" 21½” 36½” 26½” 31½” 36½” 12" 12" 12" 12" 12" 17" 32" 22" 27" 32" 15½” 12½” 15½” 14" 15½” NOTE: For reels with offset gear crank rewind, add 8" to the “F” dimension. 17 Misc. Hose Storage Devices Hump Racks Used for flat-folding fire hose storage, especially in industrial facilities • Center hump reduces weight at folds, prolonging hose life • Heavy gauge spot welded steel construction • Two piece wall bracket • Red enamel finish • FM approved Hose Capacity Fig No. Hose Size Rack & Reel Single Jacket Double Jacket A B C 46111 46112 1½” 1½” 100' 150' 50' 100' — 50' 29¾” 33½” 20f” 27f” 4¼” 4¼” 46113 46114 2½” 2½” 150' 200' 100' 150' 50' 100' 33½” 39¾” 27f” 38f” 5e” 5e” Hose Hanger Saddle Type Hose Rack Used to store hose in a protected manner • Hanger brackets are spaced for hose length and installed in “I” beam to prevent damage from material handling equipment • Hose is released with a sharp tug on the nozzle • Cast aluminum construction • Spring loaded upper hanger • Stationary lower hanger • Accommodates up to 100' of 1½” or 2½” hose Provides an economical means of storing all types of fire hose • 12 gauge welded steel construction • Red enamel finish • 16" overall width • 10" overall height Hose Size Depth Capacity SJRL Hose 46401 46402 1½” 1½” 3½” 6¼” 50' 100' 46403 46404 2½” 2½” 4½” 9" 50' 100' Fig. No. Fig. No. 46101 . . . . . . . . . . . . . . . . . . . Hose Hanger 18 Fire Hose Single Jacket Nitrile Rubber Covered For use with swinging hose reels, hump racks, or outdoor equipment houses • 100% polyester jacket • Synthetic rubber lining • Neoprene lining and/or polymer coating optional • FM approved • UL label optional on 1½” and 2½” sizes • 50', 75' or 100' length • Available with brass or aluminum couplings Used with swinging hose reels, hump racks, or outdoor equipment houses • One piece extruded construction • 100% synthetic nitrile rubber cover and lining • 100% synthetic textile reinforcement • 50', 75' or 100' length • Available in red or yellow, specify when ordering • Available with brass or aluminum couplings Fig. No. Size Proof Test Fig. No. Size Proof Test 39101 39202 1½” 1½” 300 PSI 500 PSI 39401 39404 1½” 2½” 500 PSI 500 PSI 39103 39205 2½” 2½” 300 PSI 500 PSI Double Jacket Used with swinging hose reels, hump racks, or outdoor equipment houses • Second jacket provides additional protection and increased safety factor • 100% polyester jackets • Synthetic rubber lining • Neoprene lining and/or polymer coating optional • FM approved (600 PSI hose only) • UL label optional (600 PSI hose only) • 50', 75' or 100' lengths • Available with brass or aluminum couplings Rack & Reel Used with pin racks and swinging hose reels • 100% polyester jacket • Thermoplastic lining • 1½” size FM approved • UL label optional on 1½” size • 50, 75' or 100' length • Available with brass or aluminum couplings Fig. No. Size Proof Test 39501 39502 1½” 2½” 500 PSI 500 PSI Fire Hose Options Polymer Coating: Protects hose against abrasion, chemicals, heat, and weathering. Available in red, yellow, orange, blue, green, brown, tan, and black. Neoprene Lining: Improves ozone and chemical resistance, flame retardant. 19 Fig. No. Size Proof Test 40102 40202 1½” 1½” 600 PSI 800 PSI 40105 40205 2½” 2½” 600 PSI 800 PSI Fire Hose • Couplings Non-Collapsible Hose Aluminum Hose Couplings Used with continuous flow hose reels • Rigid, non-collapsing construction allows water flow at all times • Spirally wrapped synthetic textile reinforcement • Synthetic rubber cover • 4:1 safety factor • Cut lengths to 200' Used with all types of fire hose • Attaches to hose with an internally expanded brass ring • Extruded aluminum with hard coated anodized finish • Machined thread and gasket recesses • Rocker lugs • Each set includes male and female coupling, expansion rings, and gaskets General Purpose: EPDM tube and cover • 4 ply reinforcement • Limited oil and chemical resistance Heavy Duty: NBR tube and cover • 4 ply reinforcement • Oil and chemical resistant Fig. No. Size Fig. No. Size Hose Type 1½” 1½” 1½” Rack & Reel Single Jacket Double Jacket 2½” 2½” Single Jacket Double Jacket Type Max. WP 44141 44142 44151 44145 44154 41302 41303 ¾” ¾” General Purpose Heavy Duty 200 PSI 250 PSI 41312 41313 1" 1" General Purpose Heavy Duty 200 PSI 250 PSI 41321 41323 1¼ 1¼” General Purpose Heavy Duty 150 PSI 250 PSI 41331 41333 1½” 1½” General Purpose Heavy Duty 150 PSI 250 PSI Long Shank Couplings Used with noncollapsible hose • Attaches to hose with bands, clamps, or ferrules • Cast brass • Long shank • Hexagonal wrench flats Brass Hose Couplings Used with all types of fire hose • Attaches to hose with an internally expanded brass ring • Cast or forged brass with satin finish • Machined thread and gasket recesses • Pin lugs standard • Rocker lugs optional • Each set includes male and female coupling, expansion rings, and gaskets Fig. No. Size Hose Type 44101 44102 44111 1½” 1½” 1½” Rack & Reel Single Jacket Double Jacket 44105 44114 2½” 2½” Single Jacket Double Jacket 20 Fig. No. Size Thread LS7575 LS1010 ¾” 1" GHT or NPSH NST or NPSH LS1212 LS1515 1¼” 1½” NPSH NST or NPSH Nozzles Adjustable Brass Fog Nozzles Adjustable “All Fog” Nozzle For use on Class A & B fires • Cast brass • Satin finish • Female hose thread base • Rubber bumper • Fog, straight stream, and shutoff positions • UL listed • FM approved For use on Class A, B, and C fires • Suitable for use in electrical hazard areas, at distances of 10' or more when voltage levels are below 250,000 volts • Cast brass • Satin finish • Female hose thread base • Rubber bumper • Adjustable fog and shutoff positions, no straight stream • UL listed • FM approved Fig. No. Size GPM 57101 57103 57107 1" 1½” 2½” 28 60 165 Fig. No. Size GPM 57106 1½” 65 Hose Rack Nozzle For use on Class A & B fires • Cast brass • Satin finish • Female hose thread base • Fog, straight stream, and shutoff positions • UL listed • FM approved Polycarbonate Fog Nozzles Used on Class A & B fires • Injection molded polycarbonate • Female hose thread base • Rubber bumper • Fog, straight stream, and shutoff positions • Fig. No. 57152 is ULC approved Fig. No. Size GPM 57104 1½” 60 Heavy Duty Brass Fog Nozzle For use on Class A & B fires • Forged brass with knurled barrel • Satin finish • Female hose thread base • Large rubber bumper • Fog, straight stream, and shutoff positions • ULC listed Fig. No. Size GPM 57150 57151 ¾” 1" 22 22 57152 57153 1½” 1½" 75 150 57158 57159 57156 2" 2" 2½” 75 150 150 Petrochemical Fog Nozzle Fig. No. Size GPM 57105 1½” 65 Used on Class A & B fires • Glass filled polycarbonate • Female hose thread base • Rubber bumper • Color coded “Refinery Blue” • Fog, straight stream, and shutoff positions 21 Fig. No. Size GPM 57162 1½” 75 Nozzles Polycarbonate “All Fog” Nozzle Marine Fog Nozzle Used on Class A, B, and C fires • Suitable for use in electrical hazard areas at a distance of 10' or more when voltage is lower than 250,000 volts • Injection molded polycarbonate • Female hose thread base • Rubber bumper • Adjustable fog and shutoff positions • No straight stream • ULC listed For use on Class A & B fires • Compatible with all low expansion foam concentrates • Constant gallonage is maintained through all stream pattern adjustments • Corrosion resistant brass construction • Spinning teeth for improved fog patterns • Pistol grip • Quarter turn shutoff • Female hose thread base • Rubber bumper • Fog, straight stream, and flush positions Fig. No. Size GPM 57154 1½” 75 Fig. No. Size GPM 55195 1½” 95 Heavy Duty Composite Fog Nozzles Used on Class A & B fires • Fiberglass reinforced composite material • Resistant to corrosion, heat, and impact • Black nozzle contains a higher percentage of fiberglass for added corrosion and heat resistance • Brass internals • Oversized rubber bumper • Female hose thread base • Fog, straight stream, and shutoff positions Fig. No. Color Size GPM 57172 57182 Red Black 1½” 1½” 95 95 Multiple Gallonage Nozzle Used on Class A & B fires • Selectable gallonage • Constant gallonage is maintained through all stream pattern adjustments • Corrosion resistant brass construction • Spinning teeth for improved fog patterns • Pistol grip • Quarter turn shutoff • Female hose thread swivel base • Rubber bumper • Fog, straight stream, and flush positions • Flow control ring • FM approved Constant Gallonage Nozzles For use on Class A & B fires • Compatible with all low expansion foam concentrates • Constant gallonage is maintained through all stream pattern adjustments • Lightweight hard anodized aluminum • Brass and stainless steel internals • Pistol grip • Quarter turn shutoff • Female hose thread base • Rubber bumper • Fog, straight stream, and flush positions Fig. No. Size GPM 55095 55125 1½” 1½” 95 125 22 Fig. No. Size GPM 55106 1½” 30 – 60 – 95 – 125 Nozzles & Shutoffs Shutoff Nozzle Ball Shutoffs Used on Class A fires or for washdown • Produces a long reaching straight stream • Cast brass shutoff body and nozzle tip • Female hose thread base • Quick shutoff handle • Rubber bumper • Overall length 9" Used to provide quick shutoff of water flow at nozzle base • Cast brass • Female swivel base • Male hose thread outlet • Quick shutoff handle Fig. No. Size Tip Dia. 57302 1½” ½” Fig. No. Inlet Outlet Waterway 57912 57914 1½” 2½” 1½” 1½” 1” 1d” Pistol Grip Ball Shutoffs Used to provide quick shutoff of water flow at nozzle base • Pistol grip for improved handling and control • Cast brass • Female swivel base • Male hose thread outlet • Quick shutoff handle Nozzle Tip Tip only for Fig. No. 57302 nozzle • Used on Class A fires or for washdown • Cast brass with rubber bumper • Female hose thread base • Machined tip • Overall length 4½” Fig. No. Base 57313 1½" Standard Tip Optional Tips Fig. No. Inlet Outlet Waterway ½” e” - 1c” - 1¼” 57913 57915 1½” 2½” 1½” 1½” 1” 1d” Plain Hose Nozzles Used on Class A fires or for washdown • Female hose thread base • Smooth tapered bore • Available in cast brass or red plastic Fig. Nos. Size Length — — — ¾” 1" 1¼” 6" 8" 10" 57155 — — 1½” 2" 2½” 10" 12" 12" Brass Plastic 57321 57322 57323 57324 57325 57326 23 Fire Hose Adapters Reducers Double Male Connectors Female thread larger than male thread • Cast brass with pin lugs • Rocker lugs optional • Polished brass and/or chrome plated finish optional Changes female hose thread to male hose thread • Cast brass with pin lugs • Rocker lugs optional • Polished brass and/or chrome plated finish optional Female Male Fig. No. 1" 1¼” 1¼” ¾” ¾” 1" 43107 43108 43109 1½” 1½” 1½” ¾” 1" 1¼” 43101 43131 43110 2" 2" 2" ¾” 1" 1½” 43127 43121 43141 2½” 2½” 2½” 2½” 2½” ¾” 1" 1¼” 1½” 2" 43102 43151 43152 43103 43161 3" 3" 3" 3" ¾” 1½” 2" 2½” 43137 43139 43142 43133 4" 4½” 4½” 2½” 2½” 4" 43143 43153 43154 Fig. No. 1½” 1½” 1½” 2½” 43211 43212 2½” 2½” 2½” 3" 43222 43223 Fig. No. 1" 1½” 2" 1" 1½” 2" 43311 43301 43322 2½” 2½” 2½” 1½” 2" 2½” 43321 43322 43302 3" 3" 4" 4" 4½” 2½” 3" 2½” 4" 4" 43332 43333 43342 43344 43354 Changes male hose thread to female hose thread swivel • Cast brass with pin lugs • Double swivels • Rocker lugs optional • Polished brass and/or chrome plated finish optional Used to change male size and/or thread • Male thread same size or larger than female thread • Cast brass with pin lugs • Rocker lugs optional • Polished brass and/or chrome plated finish optional Male Male Double Female Connectors Female x Male Adapters Female Male 24 Female Female Fig. No. 1" 1½” 2" 1" 1½” 2" 43411 43401 43422 2½” 2½” 3" 3" 1½” 2½” 2½” 3" 43421 43402 43432 43433 4" 4" 4½” 4½” 2½” 4" 4" 4½” 43442 43444 43454 43455 Fire Hose Adapters Double Male Hose Nipples Female x Male Hose Nipples • Used to change size and/or thread • Used to change size and/or thread • Cast brass • Cast brass • Hexagonal wrench flats • Hexagonal wrench flats Both Ends Same Size Both Ends Same Size Male Male Fig. No. Female Male Fig. No. 1" 1½” 1" 1½” 43510 43501 1" 1½" 1" 1½" 43610 43601 2" 2½” 3" 2" 2½” 3" 43522 43503 43537 2" 2½” 2" 2½” 43622 43603 4" 6" 4" 6" 43544 43566 3" 4" 6" 3" 4" 6" 43633 43644 43666 Reducing / Increasing Reducing Male Male Fig. No. Female Male Fig. No. 1" 1½” 1½” 1½” ¾” ¾” 1" 1¼” 43507 43517 43511 43512 1" 1½” 1½” 1½” ¾” ¾” 1" 1¼” 43607 43617 43611 43612 2" 2" 1" 1½” 43520 43521 2" 2" 1" 1½" 43620 43621 2½” 2½” 2½” 1" 1½” 2" 43530 43531 43552 2½” 2½” 2½” 1” 1½” 2" 43629 43630 43631 3" 3" 2" 2½” 43535 43536 3" 4" 2½” 2½” 43604 43642 4" 4½” 4½” 2½” 2½” 4" 43542 43552 43554 4½” 4½” 2½” 4" 43643 43654 6" 6" 4" 4½” 43564 43565 6" 6" 4" 4½” 43664 43665 25 Fire Hose Adapters Double Female Hose Nipples Male x Female Hose Bushings • Used to change size and/or thread • Used to change size and/or thread • Cast brass • Cast brass • Hexagonal wrench flats • Hexagonal wrench flats Female Female Fig. No. ¾” 1" 1" 1½” ¾” ¾” 1" 1" 43777 43717 43711 43712 1½” 2" 2" 2½” 1½” 1½” 2" 1¼” 43701 43721 43722 43730 2½” 2½” 2½” 3" 1½” 2" 2½” 2½” 43731 43732 43702 43733 Conversion Bushings Provides a method of converting any male hose thread to National Standard Thread (NST) as per NFPA standard 1963 • Cast brass • Female hose thread inlet • Set screw allows permanent attachment • Male NST outlet • Specify your existing male hose thread when ordering Female Male Fig. No. 2½” 4" 2½” 4½” 47942 47945 4½” 4½” 4" 4½” 47954 47955 26 Male Female Fig. No. 1" 1½” 1½” ¾” ¾” 1" 43801 43817 43802 2” 2" 2" 1" 1¼” 1½” 43809 43810 43811 2½” 2½” 2½” 1" 1½” 2" 43821 43822 43803 3" 3" 3" 1" 1½” 2½” 43831 43835 43833 4" 4" 2½” 3" 43842 43843 4½” 6" 6" 4" 4" 5" 43854 43864 43865 Fire Hose Adapters Female x Male Swivel Adapters Female x Female Swivel Adapters Allows connection of male hose coupling to standpipe system • Cast brass • Female hose thread swivel with pin lugs • Rigid male NPT outlet • Hexagonal wrench flats Allows connection of male hose coupling to standpipe system • Cast brass • Female hose thread swivel with pin lugs • Rigid male outlet • Hexagonal wrench flats Female Male NPT Fig. No. 1" 1½” 1½” 1" 1½” 2" 48810 48801 48803 2" 2" 1½” 2" 48802 48804 2½” 2½” 2½” 2½” 2½” 1" 1½” 2" 2½” 3" 48806 48808 48805 48807 48809 3" 3" 2½” 3" 48812 48811 4" 4½” 4½” 4" 4" 6" 48813 48815 48817 6" 6" 48819 Screen Material Male 2" 2½” 3" Fig. No. 1" 1½” 1½” 2" 1" 1½” 2" 2" 48820 48821 48823 48824 2½" 2½” 2½" 2½” 1½” 2" 2½” 3" 48830 48825 48827 48829 3" 3" 48831 4" 4½” 4" 4" 48833 48835 6" 6" 48839 Allows connection of fire hose to standpipe or fire sprinkler system • Cast brass • Female hose thread swivel with pin lugs • Rigid NPT male or female outlet • Hexagonal wrench flats • Selfclosing drop clapper prevents reverse water flow • UL listed Allows connection of male hose coupling to standpipe system, meter, or other device • Screen prevents entry of foreign matter • Cast brass • Available with 304 stainless steel or plastic screen • Female hose thread swivel with pin lugs* • Rigid outlet with male NPT connection • Hexagonal wrench flats 2½” 2½” 2½” Female NPT Clappered Swivel Adapters Swivel Adapters With Screen Female Female 304 SS Plastic 48805-S 48807-S 48809-S 48805-PS 48807-PS 48809-PS 27 Inlet Outlet Fig. No. 2½” (F) 2½” (F) 3" NPT (M) 3" NPT (F) 48720 48721 Angle Hose Valves Used to control the flow of water on wet standpipe systems. Commonly used with hose rack or reel units, or as a fire department outlet connection. • Cast brass construction • Replaceable rubber seat disc • Metal handwheel • Female NPT inlet • Female NPT or male hose thread outlet • 300 PSI rated • UL listed • FM approved Optional Finishes: Polished brass and/or chrome plating. Variation: With pentagonal hydrant nut to prevent unauthorized use. To Order: 1. 2. 3. 4. Select type of valve and size by Fig. No. Indicate male hose thread requirements (Fig. Nos. 48302 & 48304 only). Select optional finish and/or variation, if required. Cap & chain is ordered separately. Fig. No. FxF FxM 48301 48303 48302 48304 Size A B – Open C 1½” 2½” 2¼” 3¼” 7¾” 11" 3¾” 5" 28 Hose Gate Valves Used as a fire department outlet connection on dry standpipe systems • Also used as a pump test valve • Unrestricted waterway permits full flow • Cast brass construction • Solid wedge disc with tapered seats • Metal handwheel • NPT female inlet • Male hose thread outlet • Available with non-rising or rising stem Optional Finishes: Polished brass and/or chrome plating. To Order: 1. 2. 3. 4. Select type of valve and size by Fig. No. Indicate male hose thread requirements. Select optional finish, if required. Cap & chain is ordered separately. Non-Rising Stem Valves Fig. No. 48332 48333 48334 48335 Size PSI Rated A B C D E Listings & Approvals 2½” 2½” 3" x 2½” 4" 200 300 300 200 5¼” 5¼” 5¼” 5¼” 9¾” 9¾” 9¾” 13f” 5¾” 5¼” 5½” 6d” 2¼” 2¼” 2¼” 2¾” 3½” 3½” 3¼” 5¼” — UL, FM UL, FM — Rising Stem Valves Fig. No. 48336 48337 Size PSI Rated A B Closed B Open C D E Listings & Approvals 2½” 3" x 2½” 200 300 5¾” 5¾” 15" 15" 17½” 18" 6½” 6¼” 2¾” 2¾” 4½” 4½” — UL, FM NOTE: All valves in this series have a metal-to-metal seat. They are not recommended for use on wet standpipe systems. 29 Misc. Hose Valves Straight Globe Valves Used to control the flow of water on wet standpipe systems • Commonly used with hose rack units, hose reels, or as a fire department outlet connection • Straight globe pattern is especially suitable when water supply to hose unit is piped vertically • Cast brass • Rubber seat disc • Metal handwheel • NPT female inlet • NPT female or male hose thread outlet • 300 PSI rated Fig. Nos. FxF FxM — 48323 48322 48324 Size A B C – Open D E F 1½” 2½” 2½” 3½" 3½” 5" 8¼” 11¼” 3" 3½” 5¾” 8¼” 4¾” 7" Chicago Hose Valves Hydrant Valves Hydrant Gate Valve Used as a fire hose valve • 45° angle outlet reduces hose kinking • Cast brass • Rubber seat disc • Male NPT inlet • Male NST outlet • Tee style handle • 175 PSI rated Used as a fire department connection • Designed to prevent unauthorized use • Cast brass • Rubber seat disc • Female NPT female inlet • Male NST outlet • Pentagonal operating nut • Union bonnet • Rising stem • 300 PSI rated • Cap & chain not included — Order separately Used for fire hydrant discharge or for conducting water flow tests • Cast brass • Solid wedge disc • PTFE seat • Female hose thread swivel inlet • Male hose thread outlet • Non-rising stem • Crank style handle • 175 PSI rated Fig. No. Size 48325 . . . . . . . . . . . . . . . . 1½” 48326 . . . . . . . . . . . . . . . . 2½” Fig. No. Inlet Outlet 48319 48328 48329 48349 2½” 3" 4" 4" 2½” 2½” 2½” 4½” 30 Fig. No. Size 74999 . . . . . . . . . . . . . . . . . 2½” Sprinkler System Valves 4" Brass Check Valves Swing Check Valves Used to prevent reverse flow • Suitable for horizontal or vertical installation (upward flow only) • Cast bronze body • Bronze clapper • Rubber seat disc • Screw–in cap • Threaded ends comply with ANSI B2.1 • 200 PSI rated Used to prevent reverse water flow in fire protection systems • Normally installed between fire department connection and standpipe or sprinkler riser • Suitable for horizontal or vertical installation (upward flow only) • Forged brass body • Spring-loaded brass clapper • Tapped ½” NPT for ball drip • 250 PSI rated pressure • UL listed • FM approved Fig. No. Size Inlet Outlet 70271 70272 70273 4" 4" 4" Groove NPT (M) NPT (M) Groove Groove NPT (F) Angle GL200B-002 GL200B-005 GL200B-007 GL200B-010 ¼” ½” ¾” 1" AV200B-002 AV200B-005 AV200B-007 AV200B-010 GL200B-012 GL200B-015 GL200B-020 1¼” 1½” 2" AV200B-012 AV200B-015 AV200B-020 SC200B-005 SC200B-007 SC200B-010 ½” ¾” 1" SC200B-012 SC200B-015 SC200B-020 1¼” 1½” 2" SC200B-025 SC200B-030 SC200B-040 2½” 3" 4" Used as a sprinkler system trim valve or for manual deluge system shutoff • Quarter turn operation • Forged brass • Full port • Self-cleaning chrome plated ball • PTFE seat • Blowout proof stem • Threaded ends comply with ANSI B2.1 • ½” through 2" sizes UL listed and FM approved Used as a sprinkler system trim and drain valve • Cast bronze • Non-rising stem • Screw-in bonnet • Rubber seat disc • Metal handwheel • Threaded ends comply with ANSI B2.1 • 200 PSI rated • Available in straight globe (illustrated) or angle pattern • 2" angle pattern UL listed Size Size Full Port Ball Valves Globe & Angle Valves Globe Fig. No. 31 Fig. No. Size PSI – WOG BV600B-002 BV600U-005 BV600U-007 ¼” ½” ¾” 600 600 600 BV600U-010 BV600U-012 BV600U-015 1" 1¼” 1½” 600 600 600 BV600U-020 BV400B-025 BV400B-030 BV400B-040 2" 2½” 3" 4" 600 400 400 400 Misc. Valves & Accessories Gauge Test Valve Plastic Escutcheons Allows inspection and/or replacement of gauge without shutting off entire line • Forged brass • Rubber seat disc • Metal handwheel • ¼” NPT female inlet and outlet • 400 PSI rated Used with hose valves to trim pipe entry into cabinets • One piece flexible white plastic Fig. No. Size 43981 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1½” 43982 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2½” Fig. No. 70241 . . . . . . . . . . . . . . . . . . . . . Gauge Test Valve Split-Ring Flanges Used to trim pipe entry • Split-ring design is suitable for existing installation or new construction • Chrome plated steel with spring loaded hinge Caps & Chains Used to protect male hose threads and prevent entry of foreign matter • Available in cast brass with pin lugs or plastic with rocker lugs • Female hose thread • Attached chain • Rocker lugs optional (brass caps) • Polished brass and/or chrome plated finish optional (brass caps only) Brass Size Plastic 43900 43910 43901 ¾” 1" 1½” — — 43961 43905 43902 43907 2" 2½” 3" — 43962 43963 43903 43904 43906 4" 4½” 6" — — — Fig. No. 43991 . . 43992 . . 43993 . . 43994 . . Plastic Hydrant Caps Used to protect male hose threads and prevent entry of foreign matter • High impact yellow polycarbonate • Female hose thread • 1c” pentagonal nut Fig. No. 43972 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43974 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43975 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Size . 2½” . . 4" . 4½” 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Size 1½” 2½” . 3" . 4" Fire Department Connections Exposed Type w/ Clapper Inlets – Two Way Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Self-closing clappers prevent reverse water flow out of unconnected inlet • Exposed design simplifies installation and is suitable for new construction or remodeling • Cast brass body • 2½” swivel inlets with female hose thread • NPT female outlet • “AUTO SPKR” or “STANDPIPE” branding • 175 PSI rated Optional Finishes: Polished brass and/or chrome plating. To Order: 1. 2. 3. 4. 5. 6. Select connection by Fig. No. Indicate branding required. Select optional finish, if required. Indicate hose thread requirements. Accessories are ordered separately. See page 39. For complete units including plate and plugs see page 35. Fig. Nos. Size A B C D E 48114* 4" x 2½” x 2½” 79/16 " 115/16 " 11¼” 8½” 7¼” 48116 6" x 2½” x 2½” 10” 11½” 10¾” 9" 7¼” Straight Angle 48113* 48115 * UL listed and FM approved. 33 Fire Department Connections Exposed Type w/ Single Clapper Two Way Exposed Type w/ Clapper Inlets Three Way Fig. No. 48111 Back Outlet Fig. No. 48118 Back Outlet Fig. No. 48112 Angle Outlet Fig. No. 48119 Angle Outlet Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Self-closing clapper prevents reverse water flow out of unconnected inlet • Exposed design simplifies installation and is suitable for new construction or remodeling • Cast brass body • 2½” swivel inlets with female hose thread • 4" NPT female outlet • “AUTO SPKR” branding • UL listed • FM approved • 300 PSI rated Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Self-closing clappers prevent reverse water flow out of unconnected inlet • Exposed design simplifies installation and is suitable for new construction or remodeling • Cast brass body • 2½” swivel inlets with female hose thread • NPT female outlet • 175 PSI rated Optional Finishes: Polished brass and/or chrome plating. Optional Finishes: Polished brass and/or chrome plating. Fig. No. Size Outlet 48111 48112 4" x 2½” x 2½” 4" x 2½” x 2½” Back Angle Fig. No. Size Outlet 48118 48119 6" x 2½” x 2½” x 2½” 6" x 2½” x 2½” x 2½” Back Angle To Order Connections on Pages 34 & 35: 1. 2. 3. 4. Select connection by Fig. No. Select optional finish, if required. Indicate hose thread requirements. Accessories are ordered separately. See page 39. 34 Fire Department Connections Exposed Type – Complete Units Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Self-closing clappers prevent reverse water flow out of unconnected inlet • Exposed design simplifies installation and is suitable for new construction or remodeling • Cast brass body • 2½” swivel inlets with female hose thread • Each inlet independently clappered • NPT female outlet • Plugs & chains as required included • “AUTO SPKR” or “STANDPIPE” branding • 175 PSI rated Optional Finishes: Polished brass and/or chrome plating. Fig. No. Size 48131* 48132 4" x 2½” x 2½” 6" x 2½” x 2½” A B C 9¼” 11¼” 115/16" 11½” 79/16" 10” * Includes Fig. No. 48113 connection, UL listed and FM approved. Free Standing Type Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Selfclosing clappers prevent reverse water flow out of unconnected inlet • Free standing design is used on exterior fire lines piped vertically through the grade Two or Three Way Cast brass body • 2½” swivel inlets with female hose thread • Each inlet independently clappered • NPT female bottom outlet • 18" cover sleeve • Round identification plate • Plugs & chains as required included • “AUTO SPKR” or “STANDPIPE” branding • 175 PSI rated • Overall height 24" Four Way Cast brass body • UL listed clappered swivel adapters with 2½” inlets with female hose thread swivel • NPT female bottom outlet • 18" cover sleeve • Round identification plate • Plugs & chains as required included • “AUTO SPKR” or “STANDPIPE” branding • 175 PSI rated • Overall height 33" 48101 • 48102 48103 48105 Radius Swing Fig. No. Size 48101* 48102 4" x 2½” x 2½” 6" x 2½” x 2½” 7d” 7d” 48103 6" x 2½” x 2½” x 2½” 7¾” 48105 48106‡ 6" x 2½” x 2½” x 2½” x 2½” 6" x 2½” x 2½” x 2½” x 2½” 7½” 12½” * Includes Fig. No. 48114 connection, UL listed and FM approved. ‡ Horizontal in-line style body. Not shown above. Optional Finishes: Polished brass and/or chrome plating. 35 Fire Department Connections Flush Type Four Way Horizontal or Vertical Used to supplement the fire protection water supply • Each inlet provides a minimum of 250 GPM capacity • Self-closing clappers prevent reverse water flow out of unconnected inlet(s) • Flush design is used primarily in new construction where appearance is a consideration Straight pattern (back outlet) cast brass body with female NPT outlet • Clappered swivel adapters with 2½” inlets with female hose thread swivel • Rectangular identification plate branded “AUTO SPKR” or “STANDPIPE” • Plugs & chains • 175 PSI rated • UL listed Two & Three Way Straight pattern (back outlet) cast brass body with drop clappered inlets and female NPT outlet • 2½” inlets with female hose thread swivel • Rectangular identification plate branded “AUTO SPKR” or “STANDPIPE” • Plugs & chains • 175 PSI rated Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces Variations: Angle pattern (top or bottom outlet) brass body; polyester coated carbon steel body Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces Variation: Angle pattern (top or bottom outlet) body Fig. No. Size 48141 48142 48143 4" x 2½” x 2½” 6" x 2½” x 2½” 6" x 2½” x 2½” x 2½” Fig. No. Size Type 48154 48164 6" x 2½” x 2½” x 2½” x 2½” 6" x 2½” x 2½” x 2½” x 2½” Horizontal Vertical Listings & Approvals UL, FM UL, FM — To Order Connections on Pages 36 & 37: 1. 2. 3. Four Way Square Straight pattern (back outlet) cast brass body with female NPT outlet • UL listed clappered swivel adapters with 2½” inlets with female hose thread swivel • Rectangular identification plate branded “AUTO SPKR” or “STANDPIPE” • Plugs & chains • 175 PSI rated 4. 5. Select connection by Fig. No. Indicate branding required. Select optional finish and/or variations, if required. Indicate hose thread requirements. Accessories are ordered separately. See page 39. Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces NOTE: Dimensional drawings for these connections are provided upon request. Indicate Fig. No. and variation(s), if any, when requesting drawings. Variation: Angle pattern body Fig. No. Size 48144 . . . . . . . . . . . . . . 6" x 2½” x 2½” x 2½” x 2½” 36 Pump Test Conns. • Wall Hydrants Pump Test Connections Used to test fire pump flow capacity • Each outlet provides minimum flow of 250 GPM • Gate valves provide unrestricted waterway and control of individual outlets • Cast brass or polyester coated carbon steel body with end inlet • Brass hose gate valves with 2½” male hose thread outlet • Caps & chains • Rectangular brass identification plate lettered “PUMP TEST CONNECTION” Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces. Variations: Grooved or flanged inlet (carbon steel bodies), straight or angle inlet. Fig. No. Pump GPM Inlet Outlets Body 48621 48622 500 750 4" 6" 2 – 2½” 3 – 2½” Brass Brass 48623 48624 1000 2000 6" 8" 4 – 2½” 6 – 2½” Carbon Steel Carbon Steel Wall Hydrants – Exposed Type Wall Hydrants – Flush Type Used as a fire department outlet connection • Each outlet provides minimum flow of 250 GPM • Exposed design simplifies installation and is suitable for new construction or remodeling • Straight pattern (back inlet) cast brass body with NPT female inlet • 2½” outlets with male hose thread • Round identification plate branded “WALL HYDRANT” • Caps & chains • 175 PSI rated Used as a fire department outlet connection • Each outlet provides minimum flow of 250 GPM • Flush design is used primarily in new construction where appearance is a consideration • Straight pattern (back inlet) cast brass body with NPT female inlet • 2½” outlets with male hose thread • Rectangular identification plate branded “WALL HYDRANT” • Caps & chains • 175 PSI rated Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces. Optional Finishes: Polished brass and/or chrome plating on all exposed surfaces. Fig. No. Size 48231 . . . . . . . . . . . . . . . . . . . . . . . . 4" x 2½” x 2½” 48232 . . . . . . . . . . . . . . . . . . . . . . . . 6" x 2½” x 2½” Variations: Angle pattern (top or bottom inlet) body Fig. No. Size 48241 . . . . . . . . . . . . . . . . . . . . . . . . 4" x 2½” x 2½” 48242 . . . . . . . . . . . . . . . . . . . . . . . . 6" x 2½” x 2½” 37 Roof Manifolds Used as a fire department outlet connection • Angle valves or gate valves attach directly to body • Functions as a hydrant when furnished with male hose thread outlets • Cast brass • Straight or angle pattern body • NPT female inlet • 2½” NPT male outlets • Male hose thread outlets optional • 175 PSI rated • Valves are ordered separately In-Line Pattern Variation: With male hose thread outlets Valves attach to manifold with pipe nipples (supplied by others) • NPT female inlet(s) • NPT female outlets Two Way • Straight or Angle Pattern Vertical Fig. No. Type Size 48411 48412 Straight Straight 4" x 2½” x 2½” 6" x 2½” x 2½” 48415 48416 Angle Angle 4" x 2½” x 2½” 6" x 2½” x 2½” Fig. No. Type Size 48421 Two-way 4" x 2½” x 2½” 48424 Three-way 6" x 2½” x 2½” x 2½” Horizontal Three Way • Straight or Angle Pattern Fig. No. Type Size 48431 48432 Two-way Two-way 4" x 2½” x 2½” 6" x 2½” x 2½” 48433 48434 Three-way Three-way 4" x 2½” x 2½” x 2½” 6" x 2½” x 2½” x 2½” 48435 48436* Four-way Four-way 6" x 3" x 3" x 3" x 3" 6" x 3" x 3" x 3" x 3" * 90° angle pattern. Not shown above. Fig. No. Type Size 48414 Straight 6" x 2½” x 2½” x 2½” 48417 48418 Angle Angle 4" x 2½” x 2½” x 2½” 6" x 2½” x 2½” x 2½” 38 Accessories Round Identification Plates Used to identify and trim exposed fire department connections • Available in red plastic, brass with satin finish, or aluminum with red painted finish Fig. No. Pipe Size Material Legend 48901 48902 48904 4" 4" 4" Aluminum Brass Plastic AUTO SPKR or STANDPIPE AUTO SPKR or STANDPIPE AUTO SPKR 48903 48906 6" 6" Brass Aluminum AUTO SPKR or STANDPIPE AUTO SPKR or STANDPIPE Signs Used to identify fire department connections • Available in red enamel finished aluminum or white plastic with red lettering • Overall size 4" high x 8" wide Fig. No. Material Legend F-48-A F-51-P F-52-P F-53-P F-85-P Aluminum Plastic Plastic Plastic Plastic FIRE DEPT. CONN. DRY STANDPIPE FIRE DEPT. CONN. AUTO. SPRINKLER FIRE DEPT. CONN. FIRE DEPT. SPRINKLER CONN. WET STANDPIPE FIRE DEPT. CONN. Plugs & Chains Breakable Caps Used to protect female hose threads and prevent entry of debris • Cast brass • Male hose thread • Attached chain • Pin lugs • Rocker lugs optional • Polished brass and/or chrome plated finish optional Used to protect 2½” female hose threads and prevent entry of debris • Easily removed by a sharp blow from a spanner or hydrant wrench • Complete with eye bolts and nuts • Sold in pairs Fig. No. 43931 . . 43930 . . 43932 . . 43934 . . 43936 . . 43937 . . 43939 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Size 1½” . . 2" 2½” . . 3" . . 4" 4½” . . 6" Fig. No. Material 48911 . . . . . . . . . . . . Aluminum 48912 . . . . . . . . . . . . . . Plastic 39 Automatic Drain Devices Drains low point of standpipe system between fire department connection and check valve • Seals automatically at 7 to 10 PSI • Cast brass • NPT male ends Fig. No. Size 48921 . . . . . . . . . . . . . . . . . . ½” 48922 . . . . . . . . . . . . . . . . . . ¾” Sprinkler Accessories Head Guards Escutcheons Protects sprinkler from mechanical damage • Fits most standard ½” sprinklers • Heavy gauge spot welded steel wire • Red enamel finish Used to conceal and trim pipe penetration of finished ceiling or wall • Available in flat or telescoping two-piece adjustable style • Available in chrome or white finish – Specify when ordering Fig. No. 68951 . . . . . . . . . Economy Head Guard, One Piece 68952 . . . . . . . . . Universal Head Guard, Two Piece Sight Glass Permits inspector to check sprinkler system flow • Bronze body with clear polycarbonate windows • NPT male x NPT female connection Fig. No. Size Orifice Restriction 68961 68962 1" 1" ½ None 68963 68964 1" 1¼” 17 Fig. No. IPS Depth 68991 68992 ½” ¾” ½” ½” 68993 68994 ½” ¾” 2" - 3" Adjustable 2" - 3" Adjustable Recessed Escutcheons Used to recess sprinklers into a suspended ceiling or wall • Two piece design allows up to ¾” of adjustment • Available in chrome or white finish – Specify when ordering Fig. No. 68995 . . . . . . . . . . . . . . . ½” Recessed Escutcheon 68996 . . . . . . . . . . . . . . . ¾” Recessed Escutcheon /32" None Sprinkler Head Boxes Sprinkler Gauge Accommodates ½” or ¾” sprinklers plus wrench • Heavy gauge spot welded steel construction • Red polyester powder finish Provides accurate water pressure readings • 3½” dial • ¼” NPT stem • 0 to 300 PSI scale • UL listed • FM approved Fig. No. 68981 . . . . . . . . . . . . Sprinkler Gauge, 0 – 300 PSI Fig. No. Capacity 68971 68972 68973 12 Sprinklers 6 Sprinklers 6 ESFR Sprinklers 40 Signs • Testing Equipment Signs • Used to identify various system components • Aluminum with screen printed legend and mounting holes 2" x 6" Signs 2" x 6" Signs 7" Round Signs 68901 68902 68903 68904 68905 68906 68907 68908 68909 68913 68914 68915 68916 68917 68919 68920 68921 68922 68923 68924 68925 68926 68927 68911 68912 Air Line Alarm Line Alarm Test Anti-Freeze System Auxiliary Drain Control Valve Drain Valve Dry Standpipe Entire System Fire Sprinkler Valve From City Main In This Building In This Section Inspectors Test Main Drain Open Sprinkler Control Open Sprinkler Valve Sprinkler Control Valve Sprinkler Valve Room Test & Drain Test Valve Water Motor Line Wet Standpipe Fire Alarm Bell 911 Fire Alarm Bell 5" x 7" Sign 68918 Hydraulic System 9" x 7" Sign 68910 Fire Alarm Bell Pitot Gauge Hydrant Cap Gauges Piezometer Allows accurate pressure and flow calculations • Chrome plated tube • Liquid filled gauge with 2-1-2% accuracy in accordance with ASME/ANSI B40.1 Grade A • Includes molded plastic carrying case with foam lining • Specify scale when ordering: 0 – 160 PSI, 0 – 200 PSI, or 0 – 300 PSI Measures static (nonflowing) pressure on hydrants or standpipes • Cast brass cap with female hose thread • Bleed valve • Liquid filled gauge with • 2-12% accuracy in accordance with ASME/ANSI B40.1 Grade A • Specify scale when ordering: 0 – 160 PSI, 0 – 200 PSI, or 0 – 300 PSI Measures residual (flowing) pressure in hose lines • Cast brass body • Female hose thread swivel inlet • Male hose thread outlet • Liquid filled gauge with 2-1-2% accuracy in accordance with ASME/ANSI B40.1 Grade A • Specify scale when ordering: 0 – 160 PSI, 0 – 200 PSI, or 0 – 300 PSI Fig. No. 33201 . . . . . . . . . . Pitot Gauge Fig. No. Size 33220 . . . . . . . . . . . . . . . . 1½” 33221 . . . . . . . . . . . . . . . . 2½” Fig. No. Size 33211 . . . . . . . . . . . . . . . . . 1½” 33212 . . . . . . . . . . . . . . . . . 2½” 41 Testing Equipment Liquid Filled Pressure Gauges Inspector’s Flow Nozzle Designed specifically for fire system testing • Stainless steel case • Brass and bronze internals • Liquid filled • Acrylic window • Aluminum dial and pointer • 2½” dial •¼” NPT LM connection • 2-1-2% accuracy (ASME/ANSI B40.1 Grade A) Used to conduct fire hydrant or pump tests • Compensates for variations in i.d. of hydrant nozzle openings, eliminating the need to individually calculate hydrant’s flow coefficient • All brass construction with nickel plated finish • 2¼” i.d. smooth bore tube • Constant 0.88 coefficient of flow from 10 – 56 PSI • 6" overall length • 2½” NST female base Graduations – PSI Fig. No. Scale Major Minor PG24-060 PG24-100 PG24-160 0 – 60 PSI 0 – 100 PSI 0 – 160 PSI 5 10 20 1 2 10 PG24-200 PG24-300 0 – 200 PSI 0 – 300 PSI 20 30 10 10 Fig. No. N2517 . . . . . . . . . . . . . . . . . Inspector’s Flow Nozzle Underwriters Playpipe Used to conduct flow tests • Tapered brass tubing with marlin cord wrapping • Female hose thread base with swivel handles • Includes tip • 30" overall length • UL listed & FM approved when furnished with 1c” tip Inspector’s Test Gauges Used for testing when highly accurate measurements are required • Stainless steel case • 316 stainless steel tube and socket • Teflon coated bearings and pinion gear • Adjustable black pointer with red painted knife edge tip • Zeroadjustable white aluminum dial with polished mirror band • 3" dial • ¼” NPT LM connection • ±0.5% full scale accuracy (ASME/ANSI B40.1 Grade 2A) • Includes padded nylon carrying pouch Size Standard Tip Optional Tips 57311 2½” 1c” 1" thru 1¾” Playpipe Tip Used with Underwriters playpipe • Cast brass with satin finish • Female ULT base Fig. No. 57314 Graduations – PSI Fig. No. Fig. No. Scale Major Minor TG1084-060 TG1084-100 TG1084-160 0 – 60 PSI 0 – 100 PSI 0 – 160 PSI 5 10 20 1 2 10 TG1084-200 TG1084-300 0 – 200 PSI 0 – 300 PSI 20 30 10 10 42 Base Standard Tip Optional Tips 1½” 1c” 1" thru 1¾” Testing Equipment • Alarm Bells Water Flow Test Kits Fire Alarm Bells Signals activation of a fire alarm or sprinkler system • Steel gong • Enclosed motor • Mounts to a standard 4" conduit box • DC bells are polarized for use in supervised fire alarm systems • UL listed • FM approved • CSFM approved • Specify voltage when ordering Contains a complete assortment of instruments for testing standpipe and sprinkler systems. Each kit includes: • Pitot gauge • Piezometer • Hydrant cap gauge • Flow charts • Molded plastic carrying case with foam lining Fig. No. Size Voltage 10501 10502 10503 6" 8" 10" 6, 12, or 24 VDC 10504 10505 10506 6" 8" 10" 24 or 120 VAC Wire Bell Guard Protects fire alarm bell from mechanical damage and vandalism • Heavy gauge spotwelded steel wire • Fits bells from 6" to 10" diameter Fig. No. 10991 . . . . . . . . . . . . . . . . . . . . . . . Wire Bell Guard Weatherproof Back Box Fig. No. 33241 . . . . . . . . . . . . . . . . . 1½” Water Flow Test Kit 33242 . . . . . . . . . . . . . . . . . 2½” Water Flow Test Kit Allows bell to be installed outdoors • Standard 4" square size x 1½” deep with gasket • ½” conduit knockouts • Red finish Fig. No. 10599 . . . . . . . . . . . . . . . . . Weatherproof Back Box 43 Flow & Supervisory Switches Flow Switches Supervisory Switches Used to detect flow of water through a sprinkler system • Transmits an electrical impulse to activate audible and/or visual alarms • Continuous water flow equal to discharge from one sprinkler actuates switch • Synchronized switches activate alarm panel and local alarm bell simultaneously • Aluminum switch enclosure • Two SPDT contacts • Adjustable 090 second time delay minimizes false alarms • UL listed • FM approved • CSFM approved 10611 Detects unauthorized operation of a control valve • Transmits an electrical impulse to activate audible and/or visual alarms • Synchronized switches activate alarm panel and local alarm bell simultaneously • Aluminum switch enclosure • Two SPDT contacts • Suitable for outdoor use • UL listed • FM approved • CSFM approved Vane Type For use with Sch. 10 thru Sch. 40 steel pipe Fig. No. Pipe Size PSI Rated 10601 10602 10603 2" 2½” 3" 450 450 450 10605 10605 10606 10607 10608 3½" 4" 5" 6" 8" 450 450 450 450 450 Tee Style For use with any tee that has a 1" branch • Suitable for 1" thru 2" ferrous and non-ferrous tees, 1" thru 2" copper sweat tees, 1" CPVC tees, and 1½” polybutylene tees Fig. No. Pipe Size PSI Rated 10600* 1" thru 2" 250 10612 * UL Listed & CSFM approved only 44 Fig. No. For Use With 10611 10612 OS & Y Valves Post Indicator & Butterfly Valves Station Monitors 750 GPM Station Monitor 1250 GPM Station Monitor • Provides high volume fire protection for extra hazard areas • Provides high volume fire protection for extra hazard areas • Single waterway design reduces friction loss, improves effective reach of fire stream • Single waterway design reduces friction loss, improves effective reach of fire stream • Brass waterway • Brass waterway with turning vanes in each elbow for flow efficiency • Lever handle control • Lever handle control • Double seal swivels with locking provision and grease fittings for lubrication • Double seal swivels with locking provision and grease fittings for lubrication • Red enamel finish • Illustrated with Fig. No. 52105 nozzle (order nozzle separately) • Red enamel finish • Illustrated with Fig. No. 52105 nozzle (order nozzle separately) Fig. No. 51101 Waterway 2½” Rated Flow 750 GPM Base Flange 3" or 4" Class 150 FF Outlet 2½” NST (M) Horizontal Rotation 360° Vertical Rotation 135° Dimensions 19" H x 19" W 45 Fig. No. 51102 Waterway 3” Rated Flow 1250 GPM Base Flange 3" or 4" Class 150 FF Outlet 2½” NST (M) Horizontal Rotation 360° Vertical Rotation 150° Dimensions 17" H x 12" W Station Monitors 750 GPM Station Monitor 1250 GPM Station Monitor • Provides high volume fire protection for extra hazard areas • Provides high volume fire protection for extra hazard areas • Traditional double waterway design • • Brass waterway Single waterway design reduces friction loss, improves effective reach of fire stream • Lever handle control • Brass waterway • Double seal swivels with locking provision and grease fittings for lubrication • Vertical handwheel control • Double seal swivels with locking provision and grease fittings for lubrication • Red enamel finish • Illustrated with Fig. No. 52105 nozzle (order nozzle separately) • Red enamel finish • Illustrated with Fig. No. 52105 nozzle (order nozzle separately) Fig. No. 51201 Waterway 2" Rated Flow 750 GPM Base Flange 3" or 4" Class 150 FF Outlet 2½” NST (M) Horizontal Rotation 360° Vertical Rotation 130° Dimensions 18" H x 22" W 46 Fig. No. 51211 Waterway 3” Rated Flow 1250 GPM Base Flange 3" or 4" Class 150 FF Outlet 2½” NST (M) Horizontal Rotation 360° Vertical Rotation 150° Dimensions 17" H x 15" W Portable Monitors Portable Monitors Provides high volume fire protection for extra hazard areas • Portable design with folding legs allows monitor to be placed where needed • Single waterway design reduces friction loss, improves effective reach of fire stream • Lightweight aluminum alloy construction • Vertical handwheel control • Available with (2) 2½” NST female swivel inlets or (1) 4" or 5" Storz inlet • Spring loaded locking pins for secure base set-up • Safety stop prevents vertical rotation below 30° • Red enamel finish • Nozzle is ordered separately • Overall dimensions 25" x 26" x 16" (L x W x H) Fig. No. 51708 51710 Waterway Rated Flow Inlet Outlet 3" 3" 800 GPM 1000 GPM (2) 2½” NST (1) 4" or 5" Storz 2½” NST 2½” NST Portable Wheeled Monitor Monitor Trailer Provides high volume mobile fire protection for extra hazard areas • Four wheeled portable design is designed for one-man operation • Full flow carbon steel manifold with (2) 2½” NST female swivel inlets • 750 GPM brass monitor with 2½” waterway • Hose racks accommodate up to 100' of 2½” single jacket hose • Large 4ply pneumatic tires for easy maneuvering over rough or uneven terrain • Wheel locks • Drawbar with tee-style handle • Red enamel finish • Numerous options available • Nozzle and hose are ordered separately Provides high volume fire protection for extra hazard areas • Two wheeled portable design suitable for towing at speeds up to 25 MPH • Full flow carbon steel manifold with (2) 2½” NST female swivel inlets • 750 or 1250 GPM brass monitor with 2½” waterway • Hose racks accommodate up to 300' of 2½” double jacket hose • Large 4-ply pneumatic tires for easy maneuvering over rough or uneven terrain • Spring loaded wheel locks • Drawbar with ball or lunette-type hitch • Red enamel finish • Numerous options available • Nozzle and hose are ordered separately • Overall dimensions 80" x 65" x 52" (L x W x H) Fig. No. 51301 . . . . . . . . . . . . . . . Portable Wheeled Monitor Fig. No. 51307 . . . . . . . . . . . . . . . . 750 GPM Monitor Trailer 51312 . . . . . . . . . . . . . . . 1250 GPM Monitor Trailer 47 Master Stream Nozzles Constant Gallonage Nozzles Used on Class A & B fires • Variable fog and straight stream patterns • Constant gallonage; flow rate remains constant through all pattern adjustments • Cast brass • Rubber bumper (Fig. Nos. 52108 & 52110) • Grease fittings for lubrication • 2½” NST female base Fig. No. Size Flow GPM Length 52103 52105 52107 2½” 2½” 2½” 300 500 700 7" 7" 7" 52108 52110 2½” 2½” 750 1000 8" 8" Selectable Gallonage Nozzles Used on Class A & B fires • Variable fog and straight stream patterns • Constant gallonage; selected flow rate remains constant through all pattern adjustments • Cast brass • Large protective rubber bumper • Grease fittings for lubrication • 2½” NST female base • Overall length 8½” Fig. No. Size Flow GPM Length 52134 52157 2½” 2½” 300-400-500-600 500-750-1000-1250 8" 8½” Self-Educting Foam Nozzles Used to apply foam solution on Class B fires • Built-in eductor eliminates the need for separate foam proportioning hardware • Compatible with AFFF and ARC foam • Also suitable for wateronly use on Class A fires • Variable fog and straight stream patterns • Constant gallonage; flow rate remains constant through all pattern adjustments • Cast brass • Grease fittings for lubrication • Includes 9' clear PVC pickup hose • 2½” NST female base Fig. No. Size Flow GPM Proportioning Length 52873 52875 52877 2½” 2½” 2½” 350 500 750 6% (½, 1, or 3% optional) 3% (½ or 1% optional) 3% (½, 1, or 6% optional) 7" 7" 7" 48 Monitor Accessories Deluge Tips Monitor Hydrant Mount For use on Class A fires • Delivers a far reaching solid straight stream • Cast brass with satin finish • 2½” NST female base • Polished brass and/or chrome plated finish optional Fig. No. Length Tip Orifice 52151 52152 6¼” 9" 1" 1½” Butterfly Valves Used to control water flow to monitor • Wafer or lug style cast iron body (lug style illustrated) • Aluminum bronze disc • EPDM seat • Stainless steel stem • Locking lever handle • 200 PSI rated • Meets requirements of MSS SP-67 • Gear operator optional (suffix -G) Allows monitor to be mounted directly on hydrant • 2½” NST female swivel inlet • 3" Class 150 flange outlet • Mounting brackets with hardware included • To ensure proper fit, indicate hydrant barrel o.d. when ordering Fig. No. 52901 . . . . . . . . . . . . . . . . . . Monitor Hydrant Mount Fig. Nos. Size 3" 4" Wafer Lug 71905 71906 71915 71916 Monitor Hydrant Base Allows connection of valves and/or hose lines at base of monitor • Carbon steel construction • 6" Class 150 RF flange base • 4" Class 150 RF flange outlet • Four (4) 2½” NPT male outlets • Red polyester powder coat finish inside & out • Hose nipples and/or valves are ordered separately Fig. No. 52964 . . . . . . . . . . . . . . . . . . Monitor Hydrant Base 49 Fire Hydrant Accessories Plain Wyes Hydrant Flushing Elbows Divides one hose line into two • Cast brass construction • Female swivel inlet • Two male hose thread outlets Directs water flow away from traffic and/or landscaped areas when flushing hydrant • Cast brass swivel with female fire hose thread • Aluminum elbow • Swivels a full 360° Fig. No. Female Male (2) 74101 74102 74103 1½” 2½” 2½” 1½” 1½” 2½” 74104 74105 4" 4½” 2½” 2½” Fig. No. Size 47925 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2½” 47940 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4" 47945 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4½” Hydrant Diffusers Used for fire hydrant flushing • Directs discharge away from traffic and/or landscaped areas • Specially designed outlet and screen reduce high velocity discharge to a slower, diffused flow • Swivels a full 360° • Female hose thread swivel inlet • Carbon steel body • 304 stainless steel screen • Red polyester powder coat finish inside and out for improved appearance and corrosion resistance Gated Wye Divides one hose line into two • Forged brass • Female swivel inlet • Two male hose thread outlets • Individual quarter turn shutoffs Fig. No. Female Male (2) 74121 2½” 1½” Fig. No. Size 47825 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2½” 47840 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4" 47845 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4½” Out of Service Covers Hydrant Discharge Elbows Used for fire hydrant discharge or flow testing • Cast brass • Female swivel inlet • Male hose thread outlet Fig. No. Size Style 74901 74902 2½” 2½” 45° 90° Used to identify non-working hydrants or post indicator valves • Heavy duty nylon reinforced vinyl • Brass eyelets allow cover to be secured with ordinary nylon cable ties • Hydrant covers are available in two lengths: 30" for smaller wet barrel hydrants, 36" for standard dry barrel or 3-way wet barrel hydrants • PIV cover is 32" long to fit most vertical indicator posts • Covers are available in red or yellow with contrasting lettering Fig. No. Length Color For Use With 53471 53472 30" 30" Red Yellow Fire Hydrant Fire Hydrant 53473 53474 36" 36" Red Yellow Fire Hydrant Fire Hydrant 53475 32" Yellow Indicator Post 50 Hose House Installed adjacent to fire hydrant to store fire hose and accessory equipment. Accommodates up to 300' of 2½” double jacket fire hose plus accessories. • 16 gauge galvanized steel construction • Double doors with padlock hasp • Interior shelf for equipment storage • Suitable for wall mounting or free standing installation with optional legs • Red polyester powdercoat finish • Weatherproof Hose House Options Description Suffix Four (4) legs for free standing installation 304 stainless steel construction L SS To Order: 1. 2. 3. Select hose house by Fig. No. Select option(s), if required. Equipment is ordered separately. Fig. No. 16103 H W D 42" 58" 15" NOTES: 1. See page A9 for hose house equipment selection. 2. Fig. Nos. 16101 and 16102 are discontinued. 51 Hydrant Houses Installed over fire hydrant to store fire hose and accessory equipment. Accommodates up to 300' of 2½” double jacket fire hose plus accessories. Pentagonal • Available in pentagonal or low silhouette style • 18 gauge galvanized steel panels • Angle iron frame • Double doors with padlock hasp and embossed “FIRE HOSE” lettering • Interior shelves for equipment storage • Red zinc chromate prime coat finish • Weatherproof • FM approved Hydrant House Options Description Suffix Aluminum construction Red enamel finish AL R Low Silhouette To Order: 1. 2. 3. Select hydrant house by Fig. No. Select optional material and/or finish, if required. Equipment is ordered separately. All Models Fig. No. Style 16111 16112 16113 Pentagonal Low Silhouette Low Silhouette H W D 71" 32½” 32½” 61" 44" 55" 61" 44" 55" NOTES: 1. 2. See page A9 for hydrant house equipment selection. Fig. Nos. 16111 through 16113 are shipped unassembled. 52 Roof House Used to provide hose stations at roof level on large industrial buildings • Accommodates up to 150' of 1½” SJRL fire hose • • 14 gauge galvanized steel base 14 gauge galvanized steel cover with heavy duty hinge with brass pin 20 gauge galvanized steel hose bed with (3) access sleeves for piping connections Plated cover latch “FIRE HOSE” lettering embossed into cover Red enamel finish FM approved • • • • • Roof House Option Description Suffix Steel curb w/ red enamel finish (34¾” W x 39¾” L x 12" H) C Suggested Equipment: Fig. No. 48301 F x F angle hose valve (1½”) with extended stem Fig. No. 48321 F x F globe valve (1½”) with extended stem Fig. No. GL200B-005 F x F globe valve (½”) with extended stem Fig. No. 43501 M x M hose nipple, 1½” NPT x NST Fig. No. 57103 brass fog nozzle, 1½” NST Fig. No. 39101 SJRL fire hose, 1½”, length to suit local requirements To Order: 1. 2. 3. Select roof house by Fig. No. Select optional curb, if required. Equipment is ordered separately. Fig. No. W L H 16114 36" 40" 11" NOTE: Dimensions shown above are less curb. 53 Carts & Trailers Fire Equipment Carts Provides a ready means of storing and transporting fire protection equipment • 14 gauge welded steel construction • Large 4-ply pneumatic tires • “Fifth wheel” steering for short turning radius • Drawbar with tee-style handle • Front compartment accommodates up to four (4) portable fire extinguishers • Large rear compartment with hinged cover • Baked-on red enamel finish • Equipment is ordered separately Fig. No. Overall Dims. — W x L . . . . . . . . . Wheel Size . . . . . . . . . . . . . . . . . . Rear Box — W x L x D . . . . . . . . . Open Front — W x L x D . . . . . . . Approx. Weight . . . . . . . . . . . . . . . 73198 73199 24" x 48" 10" 24" x 29" x 20" 24" x 19" x 11" 180 lbs. 30" x 60" 12" 30" x 41" x 20" 30" x 19" x 11" 210 lbs. Hose Trailer Provides mobile storage for flat-folding fire hose • Heavy gauge steel frame and box • Hose bed constructed with redwood slats to facilitate drainage and hose drying • Ball type hitch • Pneumatic tires • Spring loaded wheel locks • Red polyester powder coat finish • Numerous options available, including tool boxes, weather cover, equipment brackets, lighting and braking systems to DOT standard Fig. No. 46301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hose Trailer 54 Tools Adjustable Hydrant Wrench Knott Spanner Fits pentagonal or square hydrant wrench to 1¾” • Spanner hook fits pin lugs or rocker lugs from 1" to 3" • Malleable iron head • Steel handle Versatile combination tool • Spanner fits pin lugs or rocker lugs to 2½” • Hydrant wrench accommodates 1c” pentagonal hydrant nut • Also incorporates shutoff key, pry bar, and hammer head • Manganese bronze Fig. No. 44603 . . . . . . . . . . . . . . Adjustable Hydrant Wrench Fig. No. 44610 . . . . . . . . . . . . . . . . . . . . . . . . Knott Spanner Heavy Duty Hydrant Wrench Fits pentagonal or square hydrant wrench to 1¾” • Spanner hook fits pin lugs or rocker lugs from 1" to 3" • Ductile iron head • Steel handle with knurled grip All Purpose Spanner Fits ¾” thru 6" pin lugs, rocker lug, slot-type, or split lug couplings • Gas cock shutoff slot • Overall length 10½” • Al-Mag 35 Alloy Fig. No. 44641 . . . . . . . . . . . . . Heavy Duty Hydrant Wrench Fig. No. 44620 . . . . . . . . . . . . . . . . . . . All Purpose Spanner Deluxe Hydrant Wrench Storz Hydrant Wrench Fits pentagonal or square hydrant wrench to 1¾” • Spanner hook fits pin lugs or rocker lugs from 1" to 3" • Ductile iron head • f” steel handle with knurled grip • Bright zinc plated Fits pentagonal hydrant nuts to 1f” and square hydrant nuts to 1½” • Combination spanner head fits pin lugs or rocker lugs from ¾” to 6" plus 4" thru 6" Storz couplings • Overall length 25" Fig. No. 44621 . . . . . . . . . . . . . . . . . . Storz Hydrant Wrench Fig. No. 44642 . . . . . . . . . . . . . . . . . Deluxe Hydrant Wrench Five Hole Hydrant Wrench Fits five common hydrant nut sizes to 1¾” • Spanner fits pin lugs or rocker lugs up to 4" • Cast brass Fig. No. 44605 . . . . . . . . . . . . . . . Five Hole Hydrant Wrench 55 Tools Common Spanners Folding Pocket Spanners Fits standard pin lug couplings or swivel adapters • Plated malleable iron Fits pin lugs or rocker lugs to 4" • Folding design minimizes storage space required • Available in die cast zinc or brass Fig. No. Size 44601 (SWP-150) . . . . . . . . . . . . . . . . . . . . . . . . 1½” 44602 (SWP-250) . . . . . . . . . . . . . . . . . . . . . . . . 2½” Fig. No. Description 44609 44619 Folding spanner, die cast zinc Folding spanner, brass Universal Spanner Fits pin lugs or rocker lugs up to 4" • Cast aluminum • Gas cock shutoff • Window jimmy Gaskets Used to seal female threaded swivels, adapters, and caps • Resilient synthetic rubber • Sized for fire hose threads Fig. No. 44605 . . . . . . . . . . . . . . . . . . . . . Universal Spanner Fig. No. 44502 . . 44504 . . 44506 . . 44507 . . 44508 . . 44510 . . 44511 . . Combination Spanners Fits pin lugs or rocker lugs up to 4" • Cast aluminum • Gas cock shutoff • Hydrant wrench Fig. No. Fits Hydrant Nut 44607 44608 1¼” Square 1½” Pentagonal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Size . 1" 1½” . 2" 2½” . 3" . 4" 4½” Breakable Padlocks Used to secure hose houses or post indicator valves and discourage tampering • Sharp blow from a hammer or spanner wrench breaks shackle • Available in two styles: brass lock casing with steel shackle or laminated steel case with steel shackle • Keyed alike Universal Post Indicator Wrench Universal replacement for use with UL/FM indicator posts made by most manufacturers • Forged steel • Red enamel finish Fig. No. 69999 . . . . . . . . . . . . . . . . . . Universal PIV Wrench Fig. No. 68997 . . . . . . . . . . . . . . . Breakable Padlock, Brass 68998 . . . . . . . . . . . . . . . . Breakable Padlock, Steel Hose & Ladder Strap Simplifies hose carrying and use on ladder • Nylon strap • Plated malleable iron fittings Fig. No. 44606 . . . . . . . . . . . . . . . . . . . Hose & Ladder Strap 56 Tools Bolt Cutters Fire Axes Cuts concrete reinforcing rods, soft bolts, rivet bars, chain • Tubular steel handles • Insulated rubber grips Used for forcible entry and cutting • Heat treated forged carbon steel head Cutting Capacity Fig. No. 69101 69102 69103 Length 18" 24" 30" Steel Copper 0.25" 0.31" 0.38" 0.38" 0.43" 0.50" Fig. No. Size Style Handle 69123 3½ lbs. Flathead 34" Fiberglass 69124 69125 6 lbs. 6 lbs. Pickhead Pickhead 36" Hickory 34" Fiberglass Wrecking Bars Forged hexagonal tool steel • Slotted claw • Beveled chisel Sledgehammers Used for forcible entry • Heat treated forged carbon steel head • Nonconductive fiberglass handle Fig. No. Head Handle 69111 69112 69113 8 lbs. 10 lbs. 12 lbs. 34" 34" 34" Fig. No. 69151 . . 69152 . . 69153 . . 69154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Size 18" 24" 30" 36" Playpipe Holder Crowbars Used with Underwriters playpipe • Black painted steel • Leather strap • Foot disc • Overall length 49" Basic forcible entry tool • Forged steel with pinch point Fig. No. 57312 . . . . . . . . . . . . . . . . . . . . . . . Playpipe Holder Fig. No. Length Bit 69141 69142 69143 69144 36" 48" 51" 60" f” 1" 1c” 1¼” Utility Lantern Used with hose and equipment houses • High density polypropylene • Heavy duty on/off switch • Uses one 6 volt lantern battery (not included) Fig. No. 18604 . . . . . . . . . . . . . . . . . . . . . . . . . Utility Lantern 57 This Page Intentionally Left Blank Appendix In specifying and applying GMR products, supplemental data is often required to develop accurate specifications and ensure that the most suitable product is selected. The reference material presented here is intended to assist in that pursuit. Our aim in this section is to address specific questions that are frequently raised when specifying and purchasing interior fire equipment. We do not claim to offer a comprehensive study of hose and standpipe systems and related equipment. There is a wealth of reference material available from well regarded sources that may be used as a guideline, and we encourage you to take advantage of those sources. For your convenience we have listed a number of them on page A12. GMR recognizes the authority having jurisdiction and recommends the standards they set relating to the products described in this catalog. Reference See Page(s) Metal Finishes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2 Cabinet Materials & Trim Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A3 Cabinet Door Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4 Variations & Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A5 Fire Hose Storage Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6 Fire Hose Test Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A7 Fire Hose Friction Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A8 Hose House Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A9 Hose Threads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A10 Conversion Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A11 Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A12 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A12 – A13 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A14 – A15 A1 Metal Finishes Cabinets Valves & Connections Steel – Cold rolled mild carbon steel with white polyester powder coating (except where noted), electrostatically applied and thermally fused at 390° F. Dry film thickness of approximately 3 mils, 1000 hours salt spray resistance. Our standard polyester powder coat may be used as a prime or finish coat. Red polyester powder coating is available as an option for a nominal charge. Brass & Bronze – Cast or forged brass or cast bronze with rough finish as manufactured. May be combined with any of the optional finishes described below. Note: The terms “brass” and “bronze” are used in this catalog to identify in general terms the various alloys used to manufacture our valves, connections, and various component parts. Bronze castings, brass forgings, or machined brass sheets are among the materials used. If you require specific identification by ASTM or UNS number please contact our office. Polyester powder coat finishes are also available in a wide range of colors. Contact GMR for complete information and color samples. A set-up charge may apply on colors that are considered non-standard. Other types of coatings including urethanes, epoxies, and hybrids are available. Contact GMR for further information. Aluminum – Type 5052H32 aluminum with bronze anodized finish or red polyester powder coat finish as described above. Optional powder coat finishes or color anodizing are available as options. Stainless Steel – Type 304 stainless steel with No. 4 brushed finish. No. 32 polished finish is available as an option. Stainless Steel – Type 304 stainless steel with No. 4 brushed finish. No. 32 polished finish is available as an option. Paint finishes as described above may also be applied to stainless steel. Polished Brass – Mirror finish machine applied to rough brass. To specify, add suffix -PB. Aluminum – Type 5005H14 aluminum with clear anodizing to minimize rust and oxidation. Color anodizing is available by special order. Rough Chrome – Copper-nickel chrome applied to rough brass. To specify, add suffix RC. Polished Chrome – Copper-nickel chrome applied to polished brass. To specify, add suffix -PC. Other Finishes – Contact GMR for availability of other finishes. A2 Cabinet Materials & Trim Styles Semi-Recessed – Used where the wall is too shallow to accept a completely recessed cabinet. A portion of the box projects beyond the finished wall. The cabinet trim surrounds the box, and returns to the finished wall, concealing the wall cut-out. The trim projection occupies a portion of the traffic area. This type of mounting increases visibility of the cabinet. When the trim projection is 4" or less this style meets the requirements of the Americans with Disabilities Act (ADA) of 1990. Cabinet Material Steel – The most widely used material. Regularly furnished with a white polyester powder coat that may be used as a prime or finish coating. Steel will accept any color to achieve the desired architectural effect, and has the added practical advantage of being the least expensive material available. Aluminum – The natural brushed appearance of aluminum provides a visually appealing installation. A clear anodized finish is standard, with various color options available. Aluminum is a good choice when added corrosion resistance is required at a moderate cost. Surface Mount – Used primarily in remodeling situations or commercial/industrial applications. The cabinet is secured to the finished wall surface or independently suspended. Corner Mounting – This is a variation of surface mounting. The cabinet is constructed with a triangular box that fits into a corner location, making maximum use of the available space. The cabinet is secured to the finished wall in the same manner as surface mount cabinets. This type of mounting is available only on our 13400 series fire extinguisher cabinets. Stainless Steel – Provides superior corrosion resistance. Often specified where appearance is a consideration. The standard finish is a No. 4 brushed finish. Cabinet Trim Styles Cabinet trim style, or mounting, is determined by several variables including wall depth, construction material, finished wall material, cabinet location, and piping arrangement. The following styles are available: Free Standing – This is also a variation of surface mounting. The cabinet is furnished with a provision for free standing installation, which may consist of legs or a fabricated steel base. The height and method of securing the cabinet to the mounting pad are determined on a caseby-case basis. Recessed – This is the most widely used mounting style where available wall depth and the piping arrangement will accommodate the complete cabinet. The flat trim neatly conceals the wall cut-out and provides minimal intrusion into traffic areas. Trimless – This is a variation of recessed mounting, used where flush installation with the finished wall is required. Available wall depth must accommodate the complete cabinet plus door & trim. A ¾” plaster flange is provided in place of the standard trim. The cabinet must be installed as a complete unit with trim behind the finished wall. A3 Cabinet Door Styles The most suitable door style for any given cabinet is usually determined by its location. For example, a cabinet located in the corridor of an office building or hospital in many cases would have a full glass door. However, that same door style would not be practical in a parking garage or college dormitory. The authority having jurisdiction should be consulted if there is any doubt as to the proper door style. In many instances there is no code requirement, and the architect or owner will determine the door style that is used. Safety Lock – This option may be combined with any of the preceding door styles for a secure, tamper-resistant installation. Specifying the safety lock feature provides a keyed-alike cylinder lock with break off tab. Opening the door requires only a sharp tug on the pull handle. Casual tampering or vandalism is effectively discouraged, while allowing full access to fire safety equipment when needed. Note: “Traditional” break glass style doors with single strength breakable glass panels have been discontinued effective March 1, 2006 and are no longer available. The following information may be used as a guide to assist the specifier in selecting the most suitable cabinet door style. Glazings – The standard glazing on all door styles, with the exception of solid panel, is clear .06" acrylic. Full Glass – This style is generally used in private businesses, hotels, and other locations where the general public’s access is limited and traffic is light. The full glass opening allows easy identification of the cabinet’s contents. Numerous optional glazings are available to achieve nearly any desired architectural effect. These include: Solid Panel – Used where complete concealment of the cabinet’s contents is desired. The door is flush with the trim, providing a flat, uninterrupted appearance. Specifying this door style with heavier gauge construction and institutional locks provides added security in prisons, mental institutions, and similar facilities. Duo Panel – This door style is a popular alternative to full glass. One third (a) of the door has a glass opening to allow identification of the cabinet’s contents; the remaining twothirds ( b) of the door is flush solid metal. The glass opening can be positioned horizontally in the upper portion of the door, or centered top to bottom. The opening can also be positioned vertically. Note: Doors with horizontal opening in the upper position are not reversible. Left hand or right hand hinging must be specified when ordering. A4 • Plate Glass • • Tempered Glass Tinted Acrylic • • Tinted Glass Wire Glass • Mirror Glass Variations & Identification Double Doors – This allows access to either the hose rack unit or fire extinguisher individually when specified on 14400, 14500, or 14600 series cabinets. This variation also reduces the radius of door swing into the corridor. Variations Our standard cabinets can be modified to include any number of variations. Some of them are described here. Please note that not all features can be combined. Concealed Hinge – Provides complete concealment of the cabinet trim and hinge by means of an oversized door. This variation is used most often with solid panel or vertical duo panel doors. When the door is closed the only part of the cabinet that is visible is the door, giving the illusion that the cabinet has been “hung” on the wall rather than recessed into it. Contact GMR for submittal and detail sheets. Duplex Construction – This variation provides access to the cabinet from both sides of a wall or partition. A second door & trim is provided, and the box is custom built to match available wall depth. The knockout location(s) must be specified at the time of ordering. Horizontal Fold – Used to provide storage of single jacket rubber lined hose without the need for a rack or reel. Retaining panels and a curved hose bed are used to hold the hose in place in the cabinet and allow quick deployment when needed. The variations described represent only a few of the special features we can provide. In may cases we can modify one of our standard products to meet your requirements. If not, we can fabricate cabinets from your drawings or we will work with you to develop a working design for a custom cabinet that will meet your particular needs. Weatherproofing – Generally used with surface mount cabinets that are installed in exposed locations. The door jamb is provided with a self-adhesive synthetic rubber gasket and a rainhood is installed over the door to direct rainfall away from the cabinet. Identification Our standard cabinet identification is a wetapplication decal or self-adhesive vinyl label with red lettering as appropriate (“FIRE EXTINGUISHER”, “FIRE HOSE”, etc. etc.). A number of optional identification techniques are available, including: Louvers – Provides ventilation for cabinets installed outdoors. These are normally located on the sides of the cabinets, but may also be located on the door. Louvers can be provided with screens inside the cabinets to discourage the entry of insects and debris. Vents and/or weep holes can also be provided. • Vinyl Lettering Special Cabinet Depth – Used when standard cabinet depth cannot accommodate required equipment. A setup charge plus a price add-on per inch of added depth applies. Specify depth required and knockout locations. • Silk Screening • Plaques & Nameplates • Individual Metal Letters • Sandblasting Full Break Glass Door – This variation provides a full glass panel door with a keyedalike cylinder lock. Single strength tempered glass is provided in place of the standard double strength glass. Note: This combination of door style and locking feature is prohibited by most authorities having jurisdiction. • Acid Etching • Stenciling • Hand Painting A5 Fire Hose Storage Devices GMR offers a complete selection of fire hose storage devices, including racks, reels, and hangers. Each type of storage device is designed for use with specific types of fire hose, and hoses are not always interchangeable. For example, double jacket hose will not work on a pin rack; neither will hose designed for continuous flow hose reels. The chart below may be used as a guideline in selecting the most suitable combination of fire hose and hose storage device. Hose Storage Device Important Note: Continuous flow hose reels are sometimes used to store flat-folding hose. In those instances, all hose must be removed from the reel before the hose valve is opened. Failure to do so will result in damage to the reel and will void our warranty. Single Jacket Rack & Reel Double Jacket Non-Collapsible Hose U Semi-Automatic Pin Racks Swinging Hose Reels U U U Hump Racks U U U Saddle-Type Hose Racks U U U Carts & Trailers U U U U Continuous Flow Hose Reels A6 Fire Hose Test Pressures Fire hoses are subjected to various pressure tests to determine their reliability. Hose is frequently identified by its proof test pressure, also known as acceptance test pressure. Proof test pressures are indicated for all fire hoses in this catalog, except as noted. With the exception of non-collapsible hose, all hose is marked with its service test pressure as per NFPA 1961 requirements. Note: Non-collapsible hose is rated according to standards established by the Rubber Manufacturers Association (RMA), which involve measurements of working pressure and bursting pressure. For this type of hose, the maximum working pressure is 25% of the minimum bursting pressure. For example, a hose rated for a 150 PSI working pressure will have a minimum bursting pressure of 600 PSI. This a commonly expressed as a “4:1 safety factor” (600 ÷ 150 = 4). Maximum working pressure is indicated for all non-collapsible hose shown in this catalog. The chart below shows typical proof test ratings for our flat folding fire hoses and the corresponding maximum working pressure, service test pressure, and burst test pressure. Test Pressures – PSI Hose Type Sizes Proof Service Burst Single Jacket 1½” & 2½” 300 500 150 250 500 750 Double Jacket 1½” & 2½” 600 800 300 400 900 1200 Rack & Reel 1½” & 2½” 500 250 750 Nitrile Rubber Covered 1½” & 2½” 500 250 750 A7 Fire Hose Friction Loss When water flows through fire hose, there is always a loss of pressure. This pressure loss is created by the friction between the moving water and the lining of the fire hose, as well as friction between the water particles. Friction Loss Coefficients: ¾” – 1100 1" – 150 1½” – 24 1¾” – 15.5 (with 1½” couplings) 2" – 8 (with 1½” couplings) 2½” – 2 Friction loss in rubber lined fire hose can be calculated using the formula FL = CQ2 L. Example: What is the friction loss at 125 GPM in a length of 1½" x 50' hose? Where: FL C Q L = = = = Friction loss in PSI Friction loss coefficient Flow rate in hundreds of GPM Hose length in hundreds of feet 24 x 1.252 x 0.5 = 18.8 PSI Note: Actual pressure loss may vary, depending on the age and condition of the hose. Friction Loss in PSI per 100' of Rubber Lined Hose Flow in GPM ¾” 1" 1½” 2½” 10 15 20 25 13.5 29.0 50.0 75.0 3.5 7.2 12.3 18.5 0.3 0.7 1.2 1.9 — — — — 30 35 40 45 105.0 140.0 — — 26.0 35.0 44.0 55.0 2.5 3.4 4.3 5.4 — — — — 50 60 70 80 — — — — 67 — — — 7.1 9.7 12.3 16.1 1.2 1.4 1.7 1.9 90 100 125 150 — — — — — — — — 20.0 25.5 36.8 50.0 2.2 2.5 4.1 5.8 175 200 225 250 — — — — — — — — — — — — 7.9 10.1 12.0 15.0 A8 Hose House Equipment GMR’s outdoor hose and hydrant houses are designed for installation adjacent to or over a fire hydrant, and will accommodate a complete selection of approved equipment. Several factors, including the type of hazard and the authority having jurisdiction will govern the selection of equipment. The two most common lists of equipment that conform to insurance requirements are published by Industrial Risk Insurers (IRI) and Factory Mutual (FM). These lists are reproduced below. Fig. No. Item IRI FM 39101 39103 1½” x 50' single jacket hose coupled brass NST . . . . . . . . . . . 2½” x 50' single jacket hose coupled brass NST . . . . . . . . . . . Note 1 Note 1 2 4 57107 57152 57311 57312 2½” adjustable brass fog nozzle . . . . . . . 1½” adjustable polycarbonate fog nozzle Underwriters playpipe . . . . . . . . . . . . . . . Playpipe holder . . . . . . . . . . . . . . . . . . . . . . . . — — 2 1 2 1 Note 2 — 43103 74121 2½” x 1½” reducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2½” x 1½” x 1½” leader line wye . . . . . . . . . . . . . . . . . . . . . . . — — 1 1 18604 44504 44507 44601 44602 44603 44606 68997 69124 69143 All purpose lantern . . . . . . 1½” hose gasket . . . . . . . . 2½” hose gasket . . . . . . . . 1½” common spanner . . . 2½” common spanner . . . Adjustable hydrant wrench Hose & ladder strap . . . . . Breakable padlock . . . . . . Fire axe . . . . . . . . . . . . . . Crowbar . . . . . . . . . . . . . . Note 3 Note 3 2 — 4 1 2 Note 3 1 1 Note 3 Note 3 — 2 4 2 — Note 3 — — . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NOTES: 1. 2. 3. Sizes and quantity of hose depends on local authority having jurisdiction. FM’s only requirement is that a sufficient number of playpipes for conducting tests be provided. Consult with the local authority having jurisdiction. These items are not required by IRI or FM, but are frequently required by the local authority having jurisdiction. A9 Hose Threads The hose threads in the accompanying tables are the most commonly used threads. However, we can supply almost any distinct or special thread you may require. Contact us for additional information. Chemical Hose Thread National Standard Thread Size ODM TPI ¾” 1" 1½” 2" 2½” 3" 4" 4½” 5" 6" 1.3750" 1.3750" 1.9900" 2.5156" 3.0686" 3.6239" 5.0109" 5.7609" 6.2600" 7.0250" 8 8 9 8 7½ 6 4 4 4 4 ODM TPI ¾” 1" 1¼” 1½” 2" 2½” 3" 4" 4½” 5" 6" 1.0353" 1.2951" 1.6399" 1.8788" 2.3582" 2.8410" 3.4670" 4.4660" 4.9850" 5.5281" 6.5848" 14 11½ 11½ 11½ 11½ 8 8 8 8 8 8 ODM TPI ¾” 1" 1¼” 1½” 2" 2½” 1.0625" 1.3125" 1.8600" 2.1000" 2.5500" 3.0350" 11 11½ 11 11 10 7½ TPI ¾” 1" 1.3750" 1.3750" 8 8 Size ODM TPI 1½" 2.1875" 12 Garden Hose Thread Size ODM TPI ¾” 1.0625" 11½ Canadian Standards Association Size ODM TPI 2½” 3.1250" 5 U.S. Navy Thread Pacific Coast Thread Size ODM Underwriters Tip Thread National Pipe Straight Hose Size Size A10 Size ODM TPI ¾” 1" 1¼” 1½” 2" 2½” 3" 4" 1.0625" 1.2951" 1.6399" 1.8788" 2.3582" 3.0686" 3.6239" 4.9082" 11½ 11½ 11½ 11½ 11½ 7½ 6 6 Conversion Tables Pressure Equivalents PSI kg/cm² kPa bar 1 0.07031 6.89476 0.06895 14.223 1 98.0665 0.980665 kPa 0.145038 0.010197 1 0.01 bar 14.5038 1.01972 100 1 m³ ft³ Gallons Liters m³ 1 35.3147 264.172 1000 ft³ 0.028317 1 7.48052 28.31687 Gallons 0.003785 0.13368 1 3.7854 0.001 0.03531 0.26417 1 lbs. kgs. oz. g lbs. 1 0.45359 16 453.592 kgs. 2.2046 1 32.15 1000 oz. 0.0625 0.02834 1 28.349 0.00205 0.001 0.3527 1 PSI kg/cm² Volume Equivalents Liters Weight Equivalents g Linear Equivalents in mm ft cm m in mm ft cm m 1 25.4 0.83 2.54 0.025 0.03937 1 0.00328 0.1 0.001 12 304.8 1 30.48 0.3048 0.3937 10 0.0328 1 0.01 39.37 1000 3.281 100 1 A11 Resources • Abbreviations Resources Abbreviations National Fire Protection Association Adj AFFF ANSI Adjustment or adjustable Aqueous film-forming foam American National Standards Institute ARC Alcohol resistant concentrate ASTM American Society for Testing and Materials AUTO Automatic AUTO SPKR Automatic Sprinkler Fire Protection Handbook 1 Fire Prevention Code 10 Portable Fire Extinguishers 13 Installation of Sprinkler Systems 14 Installation of Standpipe and Hose Systems 20 Installation of Centrifugal Fire Pumps 24 Installation of Private Fire Service Mains and Their Appurtenances 25 Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems 1961 Fire Hose 1962 Care, Use, and Service Testing of Fire Hose Including Connections and Nozzles 1963 Fire Hose Connections 1964 Spray Nozzles (Shutoff and Tip) Underwriters Laboratories Fire Protection Equipment Directory 19 Lined Fire Hose and Hose Assemblies 47 Semiautomatic Fire Hose Storage Devices 219 Lined Fire Hose for Interior Standpipes 312 Check Valves for Fire Protection Service 385 Play Pipes for Water Supply Testing in Fire Protection Service 401 Portable Spray Hose Nozzles for Fire Protection Service 405 Fire Department Connections 668 Hose Valves for Fire Protection Service 1468 Direct-Acting Pressure Reducing and Pressure Restricting Valves Factory Mutual Approval Guide Other Sources Private Fire Protection and Detection (International Fire Service Training Association) A12 CHT cm Conn. CO2 CSFM Chemical Hose Thread Centimeter Connection Carbon dioxide California State Fire Marshal D DC Dept. dia. DJRL DOT Depth Direct Current Department Diameter Double Jacket Rubber Lined Dept. of Transportation Eqpt. Extg. Equipment Extinguisher F FD FEMA FxF Fig. FxM FM ft ft3 Fahrenheit Fire department Fire Equipment Manufacturers Association Female x Female Figure Female x Male Factory Mutual Foot or feet Cubic feet g ga. gal. GHT GPM Gram Gauge Gallon Garden Hose Thread Gallons Per Minute H Height Abbreviations i.d. in. IPS IRI Inside diameter Inch Iron Pipe Size Industrial Risk Insurers kg. kg./cm² kPa Kilogram Kilograms per square centimeter Kilopascal L LPM lb. Liter Liters per minute Pound m MxM m3 max. min. mm Meter Male x Male Cubic meters Maximum Minimum Millimeter NAFED National Association of Fire Equipment Distributors National Fire Protection Association National Hose Thread Number National Pipe Straight Hose thread National Pipe Thread Non-rising stem National Standard Thread NFPA NHT no. NPSH NPT NRS NST o.d. ODM OSHA OS & Y oz. Outside diameter Outside diameter of male Occupational Safety and Health Administration Outside screw and yoke Ounce pg. P/L PSI PSIG Page Pin lug Pounds per square inch Pounds per square inch, gauge Ref. R/L RMA Reference Rocker lug Rubber Manufacturers Association Rising Stem RS A13 Sch. Sec. SJRL SPDT sq. Schedule Section Single Jacket Rubber Lined Single Pole Double Throw Square TPI Typ. Threads per inch Typical UL ULT USCG Underwriters Laboratories Underwriters Laboratories Thread United States Coast Guard VAC VDC Volts - Alternating Current Volts - Direct Current W wt. Width Weight "x" By Glossary Adapter – Any device that allows fire hose couplings to be interconnected with couplings of different sizes, threads, or mating surfaces. Double Jacket – A hose construction consisting of two woven jackets over a synthetic lining. Angle Valve – A type of globe valve used primarily as a hose valve. Dry Chemical – A mixture of fine powders that extinguishes fire by interfering with the combustion chain reaction. Booster Hose – A hose having a rubber tube, a braided or spiral reinforcement, and an outer protective cover. Normally used on continuous flow hose reels. Dry Standpipe – A standpipe system designed to have piping containing water only when the system is in use. Burst Pressure – The pressure at which hose ruptures. Fire Department Connection – A connection through which the fire department can pump water into a sprinkler or standpipe system. Cabinet – An enclosure, usually constructed of steel, that contains hose rack assemblies, Class I, II, or III fire department valves, fire extinguishers, or various combinations of these. Fire Extinguisher – A portable device containing an extinguishing agent that can be expelled under pressure for the purpose of extinguishing a fire. Carbon Dioxide – Gaseous extinguishing agent that extinguishes fire by displacing oxygen. Fire Hose – A flexible conduit constructed with one or more woven jackets and an approved nonpermeable lining. Check Valve – A valve designed to prevent reverse water flow. Fire Hydrant – A connection to a water main for the purpose of supplying water to fire hoses or other fire protection apparatus. Also see Wall Hydrant. Class A Fires – Fires in ordinary combustible materials, such as wood, cloth, paper, rubber, and many plastics. Flow Rate – A volume of fluid per unit of time passing a given cross-section of a flow passage in a given direction. Class B Fires – Fires in flammable liquids, oils, greases, tars, oil-base paints, lacquers, and flammable gases. Class C Fires – Fires that involve energized electrical equipment. Friction Loss – Pressure loss caused by friction between moving water and the interior surface of a hose or pipe. Class D Fires – Fires in combustible metals, such as magnesium, titanium, zirconium, sodium, lithium, and potassium. Gate Valve – A straightway valve with a wedge disc designed for use as an isolating or end-ofline hose valve. Coupling – One set/pair of connection devices attached to a fire hose that allows the hose to be interconnected to other hoses or fire fighting appliances. Gauge – Thickness of the steel used to manufacture cabinets. The lower the gauge, the thicker the material. A14 Glossary Globe Valve – A straightway or angle-pattern valve with a soft seating surface designed for use as a hose valve. Pressure Restricting Device – A valve or device that reduces downstream water pressure under residual (flowing) conditions only. Hose House – An enclosure located over or adjacent to a hydrant or other water supply, designed to contain hose, nozzles, and tools for use by fire fighting personnel. Proof Test – A non-destructive test applied to fire hose to determine its reliability. Proof test pressure is double the service test pressure. Hose Nozzle – A device intended for discharging water for manual suppression or extinguishment of a fire. Reducer – See adapter. Service Test – A test in which the fire hose is tested under actual working conditions. Hose Rack – A device used to store folded fire hose. Siamese – See fire department connection. Hose Reel – A circular device used to store fire hose. Single Jacket – A hose construction consisting of one woven jacket over a synthetic lining. Hose Station – A combination of a hose rack or reel, hose nozzle, hose, and hose valve. Swivel Gasket – A gasket used in a female threaded connection to provide a watertight seal between the male and female connections. Hose Valve – The valve to an individual hose connection. Tail Gasket – A gasket in the bowl of a coupling used to provide a watertight seal between the coupling and hose in an expansion ring-type coupling. Jacket – The exterior woven textile reinforcement of a fire hose. Lining – The innermost part of a hose, comprised of a continuous synthetic rubber or thermoplastic tube. Wall Hydrant – A hydrant mounted on the outside of a wall of a building, fed from interior piping, for the purpose of supplying water to fire hoses. Monitor Nozzle – A device specifically designed with a large, clear waterway to provide a powerful, far-reaching stream. Wet Standpipe – A standpipe system having piping containing water at all times. Nipple – See adapter. Polymer Coating – A protective coating applied to woven jacket fire hose in liquid form. Pressure Regulating Device – A valve or device that reduces downstream water pressure under static (non-flowing) and residual (flowing) conditions. A15 This Page Intentionally Left Blank