E1-10 - FIRST FLOOR PLAN

advertisement
5
4
3
2
D
MANUFACTURER
CAT. NO.
A
A1
A2
A5
B
C1
C5
C8
D
D1
E
EM2
EM3
EM4
EM6
EM7
EM8
EX1
EX2
EX3
F
G
H
J
K
L
L5
M
N
W1
W2
PRIMELITE
METALUX
METALUX
METALUX
CREE
CREE
JUNO
HE WILLIAMS
ONE FORTY THREE
PORTFOLIO
CUSTOM
SURE-LITES
SURE-LITES
SURE-LITES
SURE-LITES
SURE-LITES
SURE-LITES
ISOLITE
SURE-LITES
SURE-LITES
WATERWORKS
ALL MODERN
LED INSPIRATIONS
LAMPS PLUS
PENTA
CUSTOM
TUBE LIGHTING PRODUCTS
CUSTOM
HALO
MCGRAW EDISON
SYLVANIA
290-3
24EN-LD1-45-UNV-L835-CD1-U
24EN-LD1-56-UNV-L835-CD1-U
SSF-232-UNV-EB81-PB1SA
CR4-D-575L-27K-12 CT6A
LR6-DR1000
L6-23-27-1-G2-L600H-C-L-WH
LEDSQ45-OS11-827-EDD*OS-120
SHADED WALL SCONCE
HD7-7750LI
CUSTOM PROVIDED BY DESIGNER
GC-1502-2-15
CC4-WH-MRT
RLM3-15
HR-12360
12T-12-BKU
6T9-D-W-BK
2040-01-BK-20-BK
ES7-70-1-G-W
ES7-70-1-G-C
BROUGHAM BOLT01
GKV1301
PE-V2-2700-B
2X948 WAC LEDme
PANONA
CUSTOM PROVIDED BY DESIGNER
DSH-12V-W31
CUSTOM PROVIDED BY DESIGNER
102380 G25 GLOBE
IST-42-CF-120-2S-BZ-L-EM140
54757-KRE105FL
SWITCH
TYPE
SWITCH AREA
a
TICKETS
D2
b
GENERAL LIGHTING
D2
c
STEP LIGHTING
D2
d
AUD. ENTRANCE
D2
FIRST FLOOR BAR SWITCH BANK
e
f
SWITCH
LABEL
e
g
i
h
j
SWITCH
TYPE
SWITCH AREA
GENERAL LIGHTING
D2
f
PENDANTS
D2
g
LINEAR LED
D2
h
i
SCONCES
CAFE GENERAL (BULBS)
D2
D2
j
PIZZA OVEN AREA
D2
MEZZANINE BAR SWITCH BANK
k
l
SWITCH
LABEL
k
m
n
o
p
2.
SEAL CONDUITS ENTERING BOXES OF SOUND WALLS WITH RTV SILICONE SEALANT.
3.
CONDUIT ROUTED THROUGH THEATER DEMISING WALLS WILL NOT BE ALLOWED. ONLY
PENETRATIONS OF AUDITORIUM BACK WALLS AND SCREEN WALLS INTO CORRIDORS AND
PROJECTIONS BOOTHS WILL BE PERMITTED. MAKE CONDUIT PENETRATIONS THROUGH SOUND
WALLS AS FOLLOWS: CUT GYPSUM BOARD WITH CIRCULAR SAW 3/4" MAXIMUM DIAMETER LARGER
THAN CONDUIT SIZE. USE 1/2" BACKER ROD AND CAULK ANNULAR SPACE FULL WITH ACOUSTICAL
SEALANT. PROVIDE METAL ESCUTCHEON WITH LOCK-NUT ON BOTH SIDES AND SEAL AT CONDUIT
AND WALL WITH ACOUSTICAL SEALANT.
4.
LIGHT FIXTURES LOCATED IN FOOD AND STORAGE AREAS MUST HAVE SHATTERPROOF BULBS OR
COVERS.
LAMP
NO. WATTS
1
1
1
2
1
1
1
1
1
1
1
2
2
2
0
2
2
0
1
1
1
1
9W
47 W
54 W
32 W
9W
13 W
29 W
17 W
6W
10 W
1W
15 W
9W
9W
0W
12 W
9W
0W
1W
1W
10 W
8W
1
1
1
4W
250 W
10 W
1
1
1
1
10 W
15 W
42 W
60 W
TYPE
LED
LED
LED
F32T8 SPX35
LED
LED
LED
LED
LED
LED
LED
TUNG. HAL.
TUNG. HAL.
TUNG. HAL
TUNG. HAL
N/A
TUNG. HAL
N/A
LED
LED
LED
LED
LED 3.5W/FT
LED
R76
LED
LED 1.46W/FT
LED
LED
CF
LED
FINISH
MOUNTING
REMARKS
WHITE
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
MATTE BLACK
TRM6MB
WHITE
WHITE
WHITE
STANDARD
BLACK
BLACK
BLACK
BLACK W/GREEN LETTERS
ALUMINUM W/GREEN LETTERS
ALUMINUM W/GREEN LETTERS
NICKEL
HONEY GOLD
STANDARD
BRUSHED NICKEL
NICKEL
CUSTOM
STANDARD
CUSTOM
STANDARD
BRONZE
STANDARD BLACK
PENDANT
RECESSED
RECESSED
SURFACE NOTE 3
RECESSED
RECESSED
RECESSED
RECESSED
WALL
RECESSED
WALL
RECESSED
WALL
RECESSED
SURFACE W#3-BR-GY
SURFACE
RECESSED
WALL
WALL
CEILING
WALL
WALL
TAPE
WALL
FLOOR LAMP
PENDANT
SURFACE
CEILING
RECESSED
WALL
RECESSED
120V, DIMMABLE, PROVIDE 2700K 60W EQUIVALENT DIMMABLE LED BULB 800 LUMENS
120/277V, ELECTRONIC BALLAST, 4505 LUMENS
120/277V, ELECTRONIC BALLAST, 5421 LUMENS
N/A
120V, 2700K, DIMMABLE
120V, 2700K, DIMMABLE
120V, 2700K, DIMMABLE
120V, 1100 LUMENS, 2700K
120V, PROVIDE 2700K 40W EQUIVALENT 450 LUMEN LAMP
120V, PROVIDE 150W EQUIV. A19 LED LAMP, DIMMABLE
110V/220V-240V, DIMMABLE, USE 10W EQUIVALENT SOFT WHITE (2700K) T4 G9 LED LAMP
120V/277V INPUT W/12V BATTERY BACKUP
120V/277V INPUT W/12V BATTERY BACKUP
120V/277V INPUT W/6V BATTERY BACKUP
120/277V INPUT W/12V BATTERY BACKUP
12V REMOTE HEADS, ORDER 2 ASSEMBLIES FOR DOUBLE HEAD INSTALLATION
REMOTE HEAD W/6V BATTER BACKUP
SELF LUMINOUS
SELF LUMINOUS, EDGE LIT
SELF LUMINOUS, EDGE LIT
120V, 2700K, DIMMABLE, PROVIDE T10 LED BULB
120V, DIMMABLE, USE T10 LED BULB, 2700K
120V, 2700K, DIMMABLE
120V, DIMMABLE
120V
120V, 2700K, DIMMABLE
120V, NOTE 5, 3100K
120V, 2700K, DIMMABLE
120V, G25 LED BULB, DIMMABLE
120V, NOTE 6
120V, DIMMABLE CLEAN UP LIGHTS. MOUNTING HEIGHT 6" BELOW CEILING.
ELECTRICAL PLAN NOTES
1
2
3
4
5
6
7
8
9
10
11
UP TO CLEAN UP LIGHTS.
UP TO WALL SCONCE LIGHTS.
COORDINATE LOCATIONS AND DETAILS WITH ARCHITECTURAL PLANS. RE:
ACHITECTURAL PLANS.
UP TO EXTERIOR CANOPY LIGHTS.
CUSTOMER SERVICE SWITCH BANK. VERIFY LOCATION WITH OWNER.
TO EMERGENCY BATTERY BEHIND PROJECTION SCREEN. TYPICAL ALL
AUDITORIUMS.
BOOTH WORK LIGHT. CIRCUIT LIGHT THROUGH SWITCH AS SHOWN ON
PROJECTION BOOTH ELEVATION. RE: BOOTH ELEVATION DETAILS
COVE LIGHTING. COORDINATE LOCATIONS AND DETAILS WITH
ARCHITECTURAL PLANS. RE: ACHITECTURAL PLANS.
FIRST FLOOR BAR SWITCH BANK. VERIFY LOCATION WITH OWNER.
LOCATION OF SWITCH BANK. VERIFY LOCATION WITH OWNER. RE: SWITCH
BANK DETAIL.
SWITCH TO CONTROL LIGHTING CONTACTORS. VERIFY LOCATION WITH
OWNER.
LINEAR LED
TK
a r c h i t e c t s
INTERNATIONAL
106 West 11th Street
Suite 1900
Kansas City, Missouri 64105
Phone : 816-842-7552
Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE
PROPERTY OF THE DESIGN PROFESSIONAL. COPIES
OF THE DRAWINGS & SPECIFICATIONS RETAINED BY
THE CLIENT MAY BE UTILIZED ONLY FOR THEIR
USE & FOR OCCUPYING THE PROJECT FOR WHICH
THEY WERE PREPARED & NOT FOR CONSTRUCTION
OF ANY OTHER PROJECT
SWITCH
TYPE
SWITCH AREA
D2
l
SCONCES
D2
m
PENDANTS OVER SEATING
D2
n
BAR GENERAL (BULBS)
D2
o
GENERAL LIGHTING
D2
p
PENDANTS OVER BAR
D2
LIGHT FIXTURE SCHEDULE NOTES
SWITCH TYPES
D1 - 0-10V DIMMING ONLY CONTROL. LUTRON NOVA/DIVA OR COMPATIBLE.
D2 - 120V LINE VOLTAGE DIMMER. LUTRON NOVA/DIVA OR COMPATIBLE.
T - TOGGLE SWITCH.
SWITCH GENERAL NOTE
SWITCHPLATE AND SWITCH COLOR SHALL MATCH ADJACENT SURFACE OR
PER ARCHITECT DRAWINGS.
C
ALL LIGHT FIXTURES INSTALLED IN SUSPENDED CEILINGS MUST BE FASTENED TO CEILING FRAMING
MEMBERS PER NEC 410.36B.
1.
IN ADDITION TO FIXTURES SCHEDULED WITH EMERGENCY BALLAST, PROVIDE EMERGENCY BALLAST
FOR FIXTURES DESIGNATED 'EM' ON PLAN.
2.
PROVIDE BODINE EMERGENCY BALLAST CAPABLE OF PROVIDING 3,000 LUMEN OUTPUT.
3.
FIXTURE INDICATED IN ROOM WITHOUT CEILING SHALL BE SUSPENDED WITH CHAIN AT 10'-0" AFF AS
COORDINATED WITH STRUCTURE ABOVE. PROVIDE WIRE GUARD IN POD OR WHEN BELOW 8'-0" AFF.
4.
SECURE WEATHERPROOF MOUNTING BOX TO ROOF BACKING AS COORDINATED WITH ROOFING
INSTALLER.
5.
PROVIDE ALL NECESSARY TRANSFORMERS AND CONNECTORS REQUIRED FOR A COMPLETE
SYSTEM.
6.
REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHT.
P1 - 2
LC-3
4
C8
E
c
E
c
11
A. MGR.RM.
106
JAN.
101
A1
ELEC.
105
A1
A2
A1
2
C8
A1
OS
MENS
102
C8
B
B
3
B
L5
B
LV
FAM.
104
1
B
C1
F
F
EM4
OS
B
B
P1 - 6
LC-1
B
B
B
B
M
i
M
i
B
a
B
a
M
i
C5
e
M
i
C5
e
f
L
f
L
f
L
f
L
f
L
f
L
f
L
f
C5
e
M
i
C5
e
C5
e
M
i
M
i
M
i
M
i
C5
e
M
i C5
e
EX2
UP TO
LIGHT ON
EXTERIOR
MEZZ.
1
EM4
M M
i i
M
i
f
L
f
3
D1
B
A2
S8 - 16
VIA DIMMER
SCREEN 2
118
S8 - 14
VIA DIMMER
A2
C1
C1
A2
S9 - 12
B
B
S9 - 16
VIA DIMMER
S9 - 18
EX1
SCREEN 3
117
EM6
K
WOMENS
122
D1
C1
D1
S9 - 14
VIA DIMMER
C1
D1
D1
D1
6
NO.
B
B
OS
S10 - 12
EM6
EX2
K
A1
S10 - 18
S10 - 16
VIA DIMMER
EX1
S10 - 14
VIA DIMMER
D1
6
6
D1
D1
D1
D1
6
A1
EX1
6
6
C1
C1
D1
7
A2
A2
D1
C1
D1
D1 C1
EM2
D1
7
EM7
EM7
A5
D1
B
7
EM7
EM7
A5
B
B
e
g H
g
B
A2
A2
EM2
CAGE
111
EM7
A5
D1
C1 D1
D1 C1
D1
C1 D1
D1 C1
D1
A2
A1
A2
C1
A2
A1
A2
A1
PROJECT # 14059.00
OS
EM2
3
A1
A1
SPRINKLER
112
A2
A1
FIRST FLOOR
PLAN - LIGHTING
A1
A5
3
D
DRY STO.
113
9
A2
A2
A2
A1
A2
EM2
j
A2
A2
A2
A2
OS
KITCHEN
121
AUD. 2
212
AUD. 3
211
AUD. 4
210
IT RM.
116
A1
A5
OS
A1
A1
A1
A1
SECURE STO.
114
C1
j
A5
A5
SHEET NUMBER
OS
E1.10
FIRST FLOOR - LIGHTING
1/8" = 1'-0"
5
DESCRIPTION
MAIN CORRIDOR
103
CORRIDOR
110
B
e
D
h
h
DATE
EX2
A1
A2
C1
j
C1
j
S8 - 18
EX1
EM7
B
e
C1
j
B
REVISIONS
EM4
EM4
A2
C1
j
B
N
d
B
EM6
S8 - 12
B
8
EM4
M
i
C1
B
M
i
C5
e
P1 - 8
L5
EM2
C8
SCREEN 1
119
G
B
e
3
B
e
B
e
B
B
P1 - 10
LC-2
D
J
C8
A
3
G
EM4
e
C5
e
M
i
C8
M
i
5
B
a
3
EM4
B
2014.11.17
EX1
BRK. RM.
109
OS
N
d
B
B
K
G
C8
M
i
B
a
M
i
EM2
F
3
i
M
i
F
B
C1
P1 - 16
a
C8
B
C1
B
P1 - 72
VIA LC-1
TICKETS
127
EM4
OS
C1
CONF.
107
EM4
N
d
EX2
B
C5
e
C1
3
C1
1
C1
P1 - 14
EM4
CAFE
125
BID & PERMIT
C1
C1
EX1
P1 - 4
LC-2
EM4
C1
C1
G
C8
EX2
OS
EM3
8
A1
OS
C1
B
LOBBY
100
EM8
OS
A2
C8
P1 - 12
LC-2
A1
A1
B
EX2
MGR.RM.
108
OS
E
c
EM4
10
D
3
200 W MAIN ST. CHARLOTTESVILLE, VA
SWITCH
LABEL
d
c
FXT
.
LTR
.
1.
VIOLET CROWN
b
GENERAL PLAN NOTES
LIGHT FIXTURE SCHEDULE
CUSTOMER SERVICE SWITCH BANK
a
1
4
3
2
1